Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Cardiol Young ; 34(2): 262-267, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37317547

RESUMEN

BACKGROUND: Lifetime radiation exposure for paediatric orthotopic heart transplant (OHT) patients is significant with cardiac catheterisation as the dominant source. Interventional cardiac magnetic resonance is utilised to obtain simultaneous, radiation-free haemodynamics and flow/function measurements. We sought to compare invasive haemodynamic measurements and radiation exposure in traditional cardiac catheterisation, to comprehensive interventional cardiac magnetic resonance. METHODS: Twenty-eight OHT patients who underwent 67 interventional cardiac magnetic resonance procedures at Children's National Hospital were identified. Both invasive oximetry with peripheral oxygen saturation (Fick) and cardiac magnetic resonance phase contrast measurements of pulmonary and systemic blood flow were performed. Systemic and pulmonary blood flow from the two modalities was compared using Bland-Altman, concordance analysis, and inter-reader correlation. A mixed model was implemented to account for confounding variables and repeat encounters. Radiation dosage data were collected for a contemporaneous cohort of orthotopic heart transplant patients undergoing standard, X-ray-guided catheterisation. RESULTS: Simultaneous cardiac magnetic resonance and Fick have poor agreement in our study based on Lin's correlation coefficient of 0.68 and 0.73 for pulmonary and systemic blood flow, respectively. Bland-Altman analysis demonstrated a consistent over estimation of cardiac magnetic resonance cardiac output by Fick. The average indexed dose area product for patients undergoing haemodynamics with endomyocardial biopsy was 0.73 (SD ±0.6) Gy*m2/kg. With coronary angiography added, the indexed dose area product was 14.6 (SD ± 7.8) Gy*m2/kg. CONCLUSIONS: Cardiac magnetic resonancemeasurements of cardiac output/index in paediatric orthotopic heart transplant patients have poor concordance with Fick estimates; however, cardiac magnetic resonance has good internal validity and inter-reader reliability. Radiation doses are small for haemodynamics with biopsy and increase exponentially with angiography, identifying a new target for cardiac magnetic resonance imaging.


Asunto(s)
Trasplante de Corazón , Imagen por Resonancia Magnética , Niño , Humanos , Reproducibilidad de los Resultados , Cateterismo Cardíaco , Oximetría/métodos , Gasto Cardíaco/fisiología , Espectroscopía de Resonancia Magnética
2.
Cardiol Young ; 30(6): 852-859, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32456723

RESUMEN

BACKGROUND: Monitoring for acute allograft rejection improves outcomes after cardiac transplantation. Endomyocardial biopsy is the gold standard test defining rejection, but carries risk and has limitations. Cardiac magnetic resonance T2 mapping may be able to predict rejection in adults, but has not been studied in children. Our aim was to evaluate T2 mapping in identifying paediatric cardiac transplant patients with acute rejection. METHODS: Eleven paediatric transplant patients presenting 18 times were prospectively enrolled for non-contrast cardiac magnetic resonance at 1.5 T followed by endomyocardial biopsy. Imaging included volumetry, flow, and T2 mapping. Regions of interest were manually selected on the T2 maps using the middle-third technique in the left ventricular septal and lateral wall in a short-axis and four-chamber slice. Mean and maximum T2 values were compared with Student's t-tests analysis. RESULTS: Five cases of acute rejection were identified in three patients, including two cases of grade 2R on biopsy and three cases of negative biopsy treated for clinical symptoms attributed to rejection (new arrhythmia, decreased exercise capacity). A monotonic trend between increasing T2 values and higher biopsy grades was observed: grade 0R T2 53.4 ± 3 ms, grade 1R T2 54.5 ms ± 3 ms, grade 2R T2 61.3 ± 1 ms. The five rejection cases had significantly higher mean T2 values compared to cases without rejection (58.3 ± 4 ms versus 53 ± 2 ms, p = 0.001). CONCLUSIONS: Cardiac magnetic resonance with quantitative T2 mapping may offer a non-invasive method for screening paediatric cardiac transplant patients for acute allograft rejection. More data are needed to understand the relationship between T2 and rejection in children.


Asunto(s)
Rechazo de Injerto/diagnóstico por imagen , Trasplante de Corazón/efectos adversos , Imagen por Resonancia Cinemagnética , Miocardio/patología , Enfermedad Aguda , Adolescente , Niño , Preescolar , Femenino , Rechazo de Injerto/patología , Humanos , Modelos Logísticos , Masculino , Valor Predictivo de las Pruebas , Trasplante Homólogo , Resultado del Tratamiento , Estados Unidos
3.
Catheter Cardiovasc Interv ; 94(3): 399-408, 2019 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-31062506

RESUMEN

OBJECTIVES: To determine whether X-ray fused with MRI (XFM) is beneficial for select transcatheter congenital heart disease interventions. BACKGROUND: Complex transcatheter interventions often require three-dimensional (3D) soft tissue imaging guidance. Fusion imaging with live X-ray fluoroscopy can potentially improve and simplify procedures. METHODS: Patients referred for select congenital heart disease interventions were prospectively enrolled. Cardiac MRI data was overlaid on live fluoroscopy for procedural guidance. Likert scale operator assessments of value were recorded. Fluoroscopy time, radiation exposure, contrast dose, and procedure time were compared to matched cases from our institutional experience. RESULTS: Forty-six patients were enrolled. Pre-catheterization, same day cardiac MRI findings indicated intervention should be deferred in nine patients. XFM-guided cardiac catheterization was performed in 37 (median age 8.7 years [0.5-63 years]; median weight 28 kg [5.6-110 kg]) with the following prespecified indications: pulmonary artery (PA) stenosis (n = 13), aortic coarctation (n = 12), conduit stenosis/insufficiency (n = 9), and ventricular septal defect (n = 3). Diagnostic catheterization showed intervention was not indicated in 12 additional cases. XFM-guided intervention was performed in the remaining 25. Fluoroscopy time was shorter for XFM-guided intervention cases compared to matched controls. There was no significant difference in radiation dose area product, contrast volume, or procedure time. Operator Likert scores indicated XFM provided useful soft tissue guidance in all cases and was never misleading. CONCLUSIONS: XFM provides operators with meaningful three-dimensional soft tissue data and reduces fluoroscopy time in select congenital heart disease interventions.


Asunto(s)
Cateterismo Cardíaco , Cardiopatías Congénitas/diagnóstico por imagen , Cardiopatías Congénitas/terapia , Imagen por Resonancia Magnética , Radiografía Intervencional , Adolescente , Adulto , Cateterismo Cardíaco/efectos adversos , Niño , Preescolar , Toma de Decisiones Clínicas , Medios de Contraste/administración & dosificación , Femenino , Fluoroscopía , Humanos , Lactante , Imagen por Resonancia Magnética/efectos adversos , Masculino , Persona de Mediana Edad , Imagen Multimodal , Selección de Paciente , Valor Predictivo de las Pruebas , Estudios Prospectivos , Dosis de Radiación , Exposición a la Radiación , Radiografía Intervencional/efectos adversos , Factores de Riesgo , Resultado del Tratamiento , Adulto Joven
4.
J Biomech Eng ; 141(5)2019 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-30835288

RESUMEN

Patients that undergo the arterial switch operation (ASO) to repair transposition of great arteries (TGA) can develop abnormal pulmonary trunk morphology with significant long-term complications. In this study, cardiovascular magnetic resonance was combined with computational fluid dynamics to investigate the impact of the postoperative layout on the pulmonary flow patterns. Three ASO patients were analyzed and compared to a volunteer control. Results showed the presence of anomalous shear layer instabilities, vortical and helical structures, and turbulent-like states in all patients, particularly as a consequence of the unnatural curvature of the pulmonary bifurcation. Streamlined, mostly laminar flow was instead found in the healthy subject. These findings shed light on the correlation between the post-ASO anatomy and the presence of altered flow features, and may be useful to improve surgical planning as well as the long-term care of TGA patients.

5.
Paediatr Anaesth ; 29(1): 8-15, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30375141

RESUMEN

Cardiac catheterization is an integral part of medical management for pediatric patients with congenital heart disease. Owing to age and lack of cooperation in children who need this procedure, general anesthesia is typically required. These patients have increased anesthesia risk secondary to cardiac pathology. Furthermore, multiple catheterization procedures result in exposure to harmful ionizing radiation. Magnetic resonance imaging-guided right-heart catheterization offers decreased radiation exposure and diagnostic imaging benefits over traditional fluoroscopy but potentially increases anesthetic complexity and risk. We describe our early experience with anesthetic techniques and challenges for pediatric magnetic resonance imaging-guided right-heart catheterization.


Asunto(s)
Anestesia General/métodos , Cateterismo Cardíaco/métodos , Imagen por Resonancia Magnética Intervencional/métodos , Adolescente , Procedimientos Quirúrgicos Cardíacos/métodos , Niño , Preescolar , Femenino , Fluoroscopía , Cardiopatías Congénitas/diagnóstico por imagen , Cardiopatías Congénitas/cirugía , Humanos , Masculino , Adulto Joven
6.
J Cardiovasc Electrophysiol ; 28(5): 517-522, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28245348

RESUMEN

BACKGROUND: Arrhythmia ablation with current techniques is not universally successful. Inadequate ablation lesion formation may be responsible for some arrhythmia recurrences. Periprocedural visualization of ablation lesions may identify inadequate lesions and gaps to guide further ablation and reduce risk of arrhythmia recurrence. METHODS: This feasibility study assessed acute postprocedure ablation lesions by MRI, and correlated these findings with clinical outcomes. Ten pediatric patients who underwent ventricular tachycardia ablation were transferred immediately postablation to a 1.5T MRI scanner and late gadolinium enhancement (LGE) imaging was performed to characterize ablation lesions. Immediate and mid-term arrhythmia recurrences were assessed. RESULTS: Patient characteristics include median age 14 years (1-18 years), median weight 52 kg (11-81 kg), normal cardiac anatomy (n = 6), d-transposition of great arteries post arterial switch repair (n = 2), anomalous coronary artery origin post repair (n = 1), and cardiac rhabdomyoma (n = 1). All patients underwent radiofrequency catheter ablation of ventricular arrhythmia with acute procedural success. LGE was identified at the reported ablation site in 9/10 patients, all arrhythmia-free at median 7 months follow-up. LGE was not visible in 1 patient who had recurrence of frequent premature ventricular contractions within 2 hours, confirmed on Holter at 1 and 21 months post procedure. CONCLUSIONS: Ventricular ablation lesion visibility by MRI in the acute post procedure setting is feasible. Lesions identifiable with MRI may correlate with clinical outcomes. Acute MRI identification of gaps or inadequate lesions may provide the unique temporal opportunity for additional ablation therapy to decrease arrhythmia recurrence.


Asunto(s)
Ablación por Catéter , Ventrículos Cardíacos/cirugía , Imagen por Resonancia Magnética , Taquicardia Ventricular/cirugía , Adolescente , Factores de Edad , Ablación por Catéter/efectos adversos , Niño , Preescolar , Estudios de Factibilidad , Femenino , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/patología , Ventrículos Cardíacos/fisiopatología , Humanos , Lactante , Masculino , Valor Predictivo de las Pruebas , Estudios Prospectivos , Recurrencia , Factores de Riesgo , Taquicardia Ventricular/diagnóstico por imagen , Taquicardia Ventricular/fisiopatología , Factores de Tiempo , Resultado del Tratamiento
7.
J Cardiovasc Magn Reson ; 19(1): 65, 2017 Sep 06.
Artículo en Inglés | MEDLINE | ID: mdl-28874164

RESUMEN

BACKGROUND: Children with heart disease may require repeated X-Ray cardiac catheterization procedures, are more radiosensitive, and more likely to survive to experience oncologic risks of medical radiation. Cardiovascular magnetic resonance (CMR) is radiation-free and offers information about structure, function, and perfusion but not hemodynamics. We intend to perform complete radiation-free diagnostic right heart catheterization entirely using CMR fluoroscopy guidance in an unselected cohort of pediatric patients; we report the feasibility and safety. METHODS: We performed 50 CMR fluoroscopy guided comprehensive transfemoral right heart catheterizations in 39 pediatric (12.7 ± 4.7 years) subjects referred for clinically indicated cardiac catheterization. CMR guided catheterizations were assessed by completion (success/failure), procedure time, and safety events (catheterization, anesthesia). Pre and post CMR body temperature was recorded. Concurrent invasive hemodynamic and diagnostic CMR data were collected. RESULTS: During a twenty-two month period (3/2015 - 12/2016), enrolled subjects had the following clinical indications: post-heart transplant 33%, shunt 28%, pulmonary hypertension 18%, cardiomyopathy 15%, valvular heart disease 3%, and other 3%. Radiation-free CMR guided right heart catheterization attempts were all successful using passive catheters. In two subjects with septal defects, right and left heart catheterization were performed. There were no complications. One subject had six such procedures. Most subjects (51%) had undergone multiple (5.5 ± 5) previous X-Ray cardiac catheterizations. Retained thoracic surgical or transcatheter implants (36%) did not preclude successful CMR fluoroscopy heart catheterization. During the procedure, two subjects were receiving vasopressor infusions at baseline because of poor cardiac function, and in ten procedures, multiple hemodynamic conditions were tested. CONCLUSIONS: Comprehensive CMR fluoroscopy guided right heart catheterization was feasible and safe in this small cohort of pediatric subjects. This includes subjects with previous metallic implants, those requiring continuous vasopressor medication infusions, and those requiring pharmacologic provocation. Children requiring multiple, serial X-Ray cardiac catheterizations may benefit most from radiation sparing. This is a step toward wholly CMR guided diagnostic (right and left heart) cardiac catheterization and future CMR guided cardiac intervention. TRIAL REGISTRATION: ClinicalTrials.gov NCT02739087 registered February 17, 2016.


Asunto(s)
Cateterismo Cardíaco/métodos , Cardiopatías/diagnóstico , Imagen por Resonancia Magnética Intervencional , Exposición a la Radiación/prevención & control , Adolescente , Factores de Edad , Niño , Estudios de Factibilidad , Femenino , Cardiopatías/fisiopatología , Hemodinámica , Humanos , Masculino , Valor Predictivo de las Pruebas , Exposición a la Radiación/efectos adversos , Factores de Tiempo
8.
Crit Care Nurse ; 41(3): e19-e26, 2021 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-34061187

RESUMEN

BACKGROUND: The interventional cardiac magnetic resonance imaging suite combines a cardiac catheterization x-ray laboratory with a magnetic resonance imaging suite. At the study institution, interventional cardiac magnetic resonance imaging procedures (ie, magnetic resonance imaging-guided cardiac catheterizations) have been performed under institutional review board-approved research protocols since 2015. Because the workplace incorporates x-ray and magnetic resonance imaging in a highly technical environment, education about the importance of magnet safety is crucial to ensure the safety of patients and staff. OBJECTIVE: To promote magnetic resonance imaging safety and staff preparedness to respond in emergency situations in a specialized interventional cardiac magnetic resonance imaging environment. METHODS: Quarterly in situ evacuation drills with a live volunteer were implemented. A retrospective participant survey using a Likert scale was conducted. Evacuations were timed from the cardiac arrest code alert to safe evacuation or defibrillation if appropriate. RESULTS: Over 4 years, 14 drills were performed. Twenty-nine of 48 participants responded to the survey, a 60% response rate. Most participants agreed or strongly agreed that the drills were a positive experience (90%) and that the drills increased their confidence in their ability to perform in an evacuation scenario (100%). Room evacuation times improved from 71 to 41 seconds. No patient or staff safety events occurred in the interventional cardiac magnetic resonance imaging environment. CONCLUSION: Magnetic resonance imaging-guided cardiac catheterization evacuation drills promote preparedness, ensure patient and staff safety, and improve evacuation time in the interventional cardiac magnetic resonance imaging environment.


Asunto(s)
Cateterismo Cardíaco , Imagen por Resonancia Magnética Intervencional , Corazón , Humanos , Imagen por Resonancia Magnética , Estudios Retrospectivos
9.
J Ambul Care Manage ; 44(3): 184-196, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33788824

RESUMEN

The 2019 novel coronavirus disease (COVID-19) pandemic produced an abrupt and near shutdown of nonemergent patient care. Children's National Hospital (CNH) mounted a multidisciplinary, coordinated ambulatory response that included supply chain management, human resources, risk management, infection control, and information technology. To ensure patient access, CNH expanded telemedicine and instituted operational innovations for outpatient procedures. While monthly in-person ambulatory subspecialty visits decreased from 25 889 pre-COVID-19 to 4484 at nadir of the COVID-19 pandemic, telemedicine visits increased from 70 to 13 539. Further studies are needed to assess the impact of innovations in health care delivery and operations that the crisis prompted.


Asunto(s)
COVID-19/epidemiología , COVID-19/terapia , Planificación Hospitalaria , Hospitales Pediátricos/organización & administración , Servicio Ambulatorio en Hospital/organización & administración , Accesibilidad a los Servicios de Salud , Humanos , Innovación Organizacional , Pandemias , SARS-CoV-2 , Telemedicina
10.
World J Pediatr Congenit Heart Surg ; 10(5): 572-581, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31496415

RESUMEN

PURPOSE: In transposition of great arteries, increased right ventricular (RV) afterload is observed following arterial switch operation (ASO), which is not always related to pulmonary artery (PA) stenosis. We hypothesize that abnormal PA bending from the Lecompte maneuver may affect RV afterload in the absence of stenosis. Thus, we sought to identify novel measurements of three-dimensional cardiac magnetic resonance (CMR) images of the pulmonary arteries and compare with conventional measurements in their ability to predict RV afterload. METHODS: Conventional measurements and novel measurements of the pulmonary arteries were performed using CMR data from 42 ASO patients and 13 age-matched controls. Novel measurements included bending angle, normalized radius of curvature (Rc), and normalized weighted radius of curvature (Rc-w). Right ventricular systolic pressures (as the surrogate for RV afterload) were measured by either recent echocardiogram or cardiac catheterization. RESULTS: Conventional measurements of proximal PA size correlated with differential pulmonary blood flow (r = 0.49, P = .001), but not with RV peak systolic pressures (r = -0.26, P = .18). In ASO patients, Rc-w correlated with higher RV systolic pressures (r = -0.57, P = .002). Larger neoaortic areas and rightward bending angles correlated with smaller right pulmonary artery Rc (r = -0.48, P = .001; r = 0.41, P = .01, respectively). Finally, both pulmonary arteries had significantly smaller Rc compared to normal controls. CONCLUSIONS: Pulmonary arteries exhibit abnormal bends following ASO that correlate with increased RV afterload, independent of PA stenosis. Future work should focus on clinical and hemodynamic contributions of these shape parameters.


Asunto(s)
Operación de Switch Arterial/métodos , Ventrículos Cardíacos/fisiopatología , Ventrículos Cardíacos/cirugía , Arteria Pulmonar/anomalías , Arteria Pulmonar/cirugía , Adolescente , Operación de Switch Arterial/efectos adversos , Cateterismo Cardíaco , Niño , Preescolar , Constricción Patológica , Ecocardiografía , Femenino , Hemodinámica , Humanos , Pulmón , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias , Sístole , Función Ventricular Derecha
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA