Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Circ Res ; 117(3): 254-65, 2015 Jul 17.
Artículo en Inglés | MEDLINE | ID: mdl-25972514

RESUMEN

RATIONALE: After acute myocardial infarction (MI), delineating the area-at-risk (AAR) is crucial for measuring how much, if any, ischemic myocardium has been salvaged. T2-weighted MRI is promoted as an excellent method to delineate the AAR. However, the evidence supporting the validity of this method to measure the AAR is indirect, and it has never been validated with direct anatomic measurements. OBJECTIVE: To determine whether T2-weighted MRI delineates the AAR. METHODS AND RESULTS: Twenty-one canines and 24 patients with acute MI were studied. We compared bright-blood and black-blood T2-weighted MRI with images of the AAR and MI by histopathology in canines and with MI by in vivo delayed-enhancement MRI in canines and patients. Abnormal regions on MRI and pathology were compared by (a) quantitative measurement of the transmural-extent of the abnormality and (b) picture matching of contours. We found no relationship between the transmural-extent of T2-hyperintense regions and that of the AAR (bright-blood-T2: r=0.06, P=0.69; black-blood-T2: r=0.01, P=0.97). Instead, there was a strong correlation with that of infarction (bright-blood-T2: r=0.94, P<0.0001; black-blood-T2: r=0.95, P<0.0001). Additionally, contour analysis demonstrated a fingerprint match of T2-hyperintense regions with the intricate contour of infarcted regions by delayed-enhancement MRI. Similarly, in patients there was a close correspondence between contours of T2-hyperintense and infarcted regions, and the transmural-extent of these regions were highly correlated (bright-blood-T2: r=0.82, P<0.0001; black-blood-T2: r=0.83, P<0.0001). CONCLUSION: T2-weighted MRI does not depict the AAR. Accordingly, T2-weighted MRI should not be used to measure myocardial salvage, either to inform patient management decisions or to evaluate novel therapies for acute MI.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Infarto del Miocardio/patología , Miocardio/patología , Adulto , Anciano , Animales , Circulación Coronaria , Diagnóstico Diferencial , Perros , Edema/patología , Determinación de Punto Final , Femenino , Colorantes Fluorescentes , Corazón/fisiopatología , Humanos , Masculino , Microesferas , Persona de Mediana Edad , Infarto del Miocardio/sangre , Infarto del Miocardio/inducido químicamente , Infarto del Miocardio/fisiopatología , Tamaño de los Órganos , Compuestos Organometálicos , Estudios Prospectivos , Riesgo , Troponina T/sangre
2.
J Electrocardiol ; 46(3): 256-62, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23562751

RESUMEN

BACKGROUND: Patients with ostium secundum atrial septal defects (ASDs) were studied to determine the prevalence of Selvester anteroseptal myocardial infarction QRS points, and to test the hypothesis that there is a relationship between these criteria and thinning and/or scarring of the inter-ventricular septum (IVS). METHODS: Demographic, electrocardiographic (ECG), and cardiac magnetic resonance imaging (CMR) data were acquired on 46 patients with a secundum ASD closed percutaneously. Selvester QRS scoring on patient ECGs was performed for areas representing the anteroseptal region of the left ventricle (LV). The IVS to LV free wall thickness ratio was used to assess thinning of the IVS while late gadolinium enhancement (LGE) of the IVS was used for scarring; both using CMR. RESULTS: Twenty-four (52%) patients scored Selvester QRS points in the anteroseptal region with a mean score of 2.6±1.8. The mean IVS/LV free wall thickness ratio at the basal level and mid-ventricular level was 1.1±0.3 and 1.3±0.3, respectively. There was no association of Selvester QRS points with IVS/LV free wall ratio at the basal (p=0.59) or mid-ventricular (p=0.13) levels. The one patient with LGE in the IVS had 4 Selvester anteroseptal QRS points. CONCLUSION: The results of our study demonstrate that in our patient population there is a 52% prevalence of Selvester anteroseptal QRS points which are due to thinning and/or scarring of the IVS in only one patient.


Asunto(s)
Diagnóstico por Computador/métodos , Electrocardiografía/métodos , Imagen por Resonancia Cinemagnética/métodos , Infarto del Miocardio/diagnóstico , Índice de Severidad de la Enfermedad , Disfunción Ventricular Derecha/diagnóstico , Tabique Interventricular/patología , Adolescente , Adulto , Anciano de 80 o más Años , Algoritmos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/complicaciones , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Disfunción Ventricular Derecha/complicaciones , Adulto Joven
3.
J Electrocardiol ; 43(2): 161-6, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-19959184

RESUMEN

BACKGROUND: This study was performed to test the hypothesis that there exists a correlation between the Butler-Leggett (BL) criterion for right ventricular hypertrophy on the electrocardiogram and the Qp/Qs shunt ratio in adults with ostium secundum atrial septal defects (ASDs). METHODS: Demographic, cardiac catheterization, ASD closure, and electrocardiographic data were acquired on 70 patients with secundum ASDs closed percutaneously. Simple linear regression and logistic regression models were created to test the hypothesis. RESULTS: The mean Qp/Qs ratio and BL criterion value were 1.61 +/- 0.46 and 0.11 +/- 0.41, respectively. The BL criterion values correlated with shunt ratios (r(2) = 0.11 and P = .004). A BL criterion value greater than 0 mV predicted a significant shunt ratio (Qp/Qs > or = 1.5) (odds ratio, 4.8; 95% confidence interval, 1.3, 18.1; P = or <.0001) with a sensitivity of 0.68 and specificity of 0.65. CONCLUSION: Our results indicate that there is limited utility of the BL criterion at detecting right ventricular volume overload, although a BL criterion value greater than 0 mV being used to identify patients with significant intracardiac shunts yielded a sensitivity of 0.68 and specificity of 0.65.


Asunto(s)
Algoritmos , Diagnóstico por Computador/métodos , Electrocardiografía/métodos , Defectos del Tabique Interatrial/complicaciones , Defectos del Tabique Interatrial/diagnóstico , Hipertrofia Ventricular Derecha/complicaciones , Hipertrofia Ventricular Derecha/diagnóstico , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Adulto Joven
4.
Artículo en Inglés | MEDLINE | ID: mdl-30530322

RESUMEN

Stress echocardiography is used to detect myocardial ischemia by evaluating cardiovascular function both at rest and at elevated heart rates. Stress echocardiography requires excellent visualization of the left ventricle (LV) throughout the cardiac cycle. However, LV endocardial border visualization is often negatively impacted by high levels of clutter associated with patient obesity, which has risen dramatically worldwide in recent decades. Short-lag spatial coherence (SLSC) imaging has demonstrated reduced clutter in several applications. In this work, a computationally efficient formulation of SLSC was implemented into an object-oriented graphics processing unit-based software beamformer, enabling real-time (>30 frames per second) SLSC echocardiography on a research ultrasound scanner. The system was then used to image 15 difficult-to-image stress echocardiography patients in a comparison study of tissue harmonic imaging (THI) and harmonic spatial coherence imaging (HSCI). Video clips of four standard stress echocardiography views acquired with either THI or HSCI were provided in random shuffled order to three experienced readers. Each reader rated the visibility of 17 LV segments as "invisible," "suboptimally visualized," or "well visualized," with the first two categories indicating a need for contrast agent. In a symmetry test unadjusted for patientwise clustering, HSCI demonstrated a clear superiority over THI ( ). When measured on a per-patient basis, the median total score significantly favored HSCI with . When collapsing the ratings to a two-level scale ("needs contrast" versus "well visualized"), HSCI once again showed an overall superiority over THI, with by McNemar test adjusted for clustering.


Asunto(s)
Ecocardiografía de Estrés/métodos , Corazón/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Algoritmos , Artefactos , Humanos
5.
JACC Cardiovasc Imaging ; 11(12): 1758-1769, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-29248655

RESUMEN

OBJECTIVES: This study introduced and validated a novel flow-independent delayed enhancement technique that shows hyperenhanced myocardium while simultaneously suppressing blood-pool signal. BACKGROUND: The diagnosis and assessment of myocardial infarction (MI) is crucial in determining clinical management and prognosis. Although delayed enhancement cardiac magnetic resonance (DE-CMR) is an in vivo reference standard for imaging MI, an important limitation is poor delineation between hyperenhanced myocardium and bright LV cavity blood-pool, which may cause many infarcts to become invisible. METHODS: A canine model with pathology as the reference standard was used for validation (n = 22). Patients with MI and normal controls were studied to ascertain clinical performance (n = 31). RESULTS: In canines, the flow-independent dark-blood delayed enhancement (FIDDLE) technique was superior to conventional DE-CMR for the detection of MI, with higher sensitivity (96% vs. 85%, respectively; p = 0.002) and accuracy (95% vs. 87%, respectively; p = 0.01) and with similar specificity (92% vs, 92%, respectively; p = 1.0). In infarcts that were identified by both techniques, the entire length of the endocardial border between infarcted myocardium and adjacent blood-pool was visualized in 33% for DE-CMR compared with 100% for FIDDLE. There was better agreement for FIDDLE-measured infarct size than for DE-CMR infarct size (95% limits-of-agreement, 2.1% vs. 5.5%, respectively; p < 0.0001). In patients, findings were similar. FIDDLE demonstrated higher accuracy for diagnosis of MI than DE-CMR (100% [95% confidence interval [CI]: 89% to 100%] vs. 84% [95% CI: 66% to 95%], respectively; p = 0.03). CONCLUSIONS: The study introduced and validated a novel CMR technique that improves the discrimination of the border between infarcted myocardium and adjacent blood-pool. This dark-blood technique provides diagnostic performance that is superior to that of the current in vivo reference standard for the imaging diagnosis of MI.


Asunto(s)
Imagen por Resonancia Magnética , Infarto del Miocardio/diagnóstico por imagen , Miocardio/patología , Adulto , Anciano , Animales , Estudios de Casos y Controles , Medios de Contraste/administración & dosificación , Circulación Coronaria , Modelos Animales de Enfermedad , Perros , Humanos , Persona de Mediana Edad , Infarto del Miocardio/patología , Infarto del Miocardio/fisiopatología , Compuestos Organometálicos/administración & dosificación , Proyectos Piloto , Valor Predictivo de las Pruebas , Pronóstico , Reproducibilidad de los Resultados , Supervivencia Tisular , Adulto Joven
6.
Artículo en Inglés | MEDLINE | ID: mdl-27913342

RESUMEN

The spatial coherence of ultrasound backscatter has been proposed to reduce clutter in medical imaging, to measure the anisotropy of the scattering source, and to improve the detection of blood flow. These techniques rely on correlation estimates that are obtained using computationally expensive strategies. In this paper, we assess the existing spatial coherence estimation methods and propose three computationally efficient modifications: a reduced kernel, a downsampled receive aperture, and the use of an ensemble correlation coefficient. The proposed methods are implemented in simulation and in vivo studies. Reducing the kernel to a single sample improved computational throughput and improved axial resolution. Downsampling the receive aperture was found to have negligible effect on estimator variance, and improved computational throughput by an order of magnitude for a downsample factor of 4. The ensemble correlation estimator demonstrated lower variance than the currently used average correlation. Combining the three methods, the throughput was improved 105-fold in simulation with a downsample factor of 4- and 20-fold in vivo with a downsample factor of 2.


Asunto(s)
Algoritmos , Procesamiento de Imagen Asistido por Computador/métodos , Ultrasonografía/métodos , Simulación por Computador , Ecocardiografía , Corazón/diagnóstico por imagen , Humanos , Dispersión de Radiación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA