Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Circulation ; 149(25): 1938-1948, 2024 06 18.
Artículo en Inglés | MEDLINE | ID: mdl-38804148

RESUMEN

BACKGROUND: Ascending aorta dilation and aortic valve degeneration are common complications in patients with bicuspid aortic valve. Several retrospective studies have suggested the benefit of statins in reducing these complications. This study aimed to determine whether atorvastatin treatment is effective in reducing the growth of aortic diameters in bicuspid aortic valve and if it slows the progression of valve calcification. METHODS: In a randomized clinical trial, 220 patients with bicuspid aortic valve (43 women; 46±13 years of age) were included and treated with either 20 mg of atorvastatin per day or placebo for 3 years. Inclusion criteria were ≥18 years of age, nonsevere valvular dysfunction, nonsevere valve calcification, and ascending aorta diameter ≤50 mm. Computed tomography and echocardiography studies were performed at baseline and after 3 years of treatment. RESULTS: During follow-up, 28 patients (12.7%) discontinued medical treatment (15 on atorvastatin and 13 taking placebo). Thus, 192 patients completed the 36 months of treatment. Low-density lipoprotein cholesterol levels decreased significantly in the atorvastatin group (median [interquartile range], -30 mg/dL [-51.65 to -1.75 mg/dL] versus 6 mg/dL [-4, 22.5 mg/dL]; P<0.001). The maximum ascending aorta diameter increased with no differences between groups: 0.65 mm (95% CI, 0.45-0.85) in the atorvastatin group and 0.74 mm (95% CI, 0.45-1.04) in the placebo group (P=0.613). Similarly, no significant differences were found for the progression of the aortic valve calcium score (P=0.167) or valvular dysfunction. CONCLUSIONS: Among patients with bicuspid aortic valve without severe valvular dysfunction, atorvastatin treatment was not effective in reducing the progression of ascending aorta dilation and aortic valve calcification during 3 years of treatment despite a significant reduction in low-density lipoprotein cholesterol levels. REGISTRATION: URL: https://www.clinicaltrialsregister.eu; Unique identifier: 2015-001808-57. URL: https://www.clinicaltrials.gov; Unique identifier: NCT02679261.


Asunto(s)
Válvula Aórtica , Atorvastatina , Enfermedad de la Válvula Aórtica Bicúspide , Calcinosis , Progresión de la Enfermedad , Enfermedades de las Válvulas Cardíacas , Inhibidores de Hidroximetilglutaril-CoA Reductasas , Humanos , Atorvastatina/uso terapéutico , Femenino , Masculino , Persona de Mediana Edad , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/patología , Válvula Aórtica/anomalías , Válvula Aórtica/efectos de los fármacos , Calcinosis/tratamiento farmacológico , Calcinosis/diagnóstico por imagen , Calcinosis/patología , Enfermedad de la Válvula Aórtica Bicúspide/diagnóstico por imagen , Enfermedad de la Válvula Aórtica Bicúspide/tratamiento farmacológico , Enfermedades de las Válvulas Cardíacas/tratamiento farmacológico , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/patología , Adulto , Inhibidores de Hidroximetilglutaril-CoA Reductasas/uso terapéutico , Dilatación Patológica/tratamiento farmacológico , Estudios de Seguimiento , Método Doble Ciego , Resultado del Tratamiento , Aorta/diagnóstico por imagen , Aorta/patología , Aorta/efectos de los fármacos , Enfermedad de la Válvula Aórtica/tratamiento farmacológico , Estenosis de la Válvula Aórtica
2.
Eur Radiol ; 34(8): 5190-5200, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38183450

RESUMEN

OBJECTIVES: Partial thrombosis of the false lumen (FL) in patients with chronic aortic dissection (AD) of the descending aorta has been associated with poor outcomes. Meanwhile, the fluid dynamic and biomechanical characteristics associated with partial thrombosis remain to be elucidated. This retrospective, single-center study tested the association between FL fluid dynamics and biomechanics and the presence and extent of FL thrombus. METHODS: Patients with chronic non-thrombosed or partially thrombosed FLs in the descending aorta after an aortic dissection underwent computed tomography angiography, cardiovascular magnetic resonance (CMR) angiography, and a 4D flow CMR study. A comprehensive quantitative analysis was performed to test the association between FL thrombus presence and extent (percentage of FL with thrombus) and FL anatomy (diameter, entry tear location and size), fluid dynamics (inflow, rotational flow, wall shear stress, kinetic energy, and flow acceleration and stasis), and biomechanics (pulse wave velocity). RESULTS: Sixty-eight patients were included. In multivariate logistic regression FL kinetic energy (p = 0.038) discriminated the 33 patients with partial FL thrombosis from the 35 patients with no thrombosis. Similarly, in separated multivariate linear correlations kinetic energy (p = 0.006) and FL inflow (p = 0.002) were independently related to the extent of the thrombus. FL vortexes, flow acceleration and stasis, wall shear stress, and pulse wave velocity showed limited associations with thrombus presence and extent. CONCLUSION: In patients with chronic descending aorta dissection, false lumen kinetic energy is related to the presence and extent of false lumen thrombus. CLINICAL RELEVANCE STATEMENT: In patients with chronic aortic dissection of the descending aorta, false lumen hemodynamic parameters are closely linked with the presence and extent of false lumen thrombosis, and these non-invasive measures might be important in patient management. KEY POINTS: • Partial false lumen thrombosis has been associated with aortic growth in patients with chronic descending aortic dissection; therefore, the identification of prothrombotic flow conditions is desirable. • The presence of partial false lumen thrombosis as well as its extent was related with false lumen kinetic energy. • The assessment of false lumen hemodynamics may be important in the management of patients with chronic aortic dissection of the descending aorta.


Asunto(s)
Aorta Torácica , Disección Aórtica , Hemodinámica , Trombosis , Humanos , Masculino , Femenino , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/fisiopatología , Disección Aórtica/complicaciones , Persona de Mediana Edad , Estudios Retrospectivos , Trombosis/diagnóstico por imagen , Trombosis/fisiopatología , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/fisiopatología , Angiografía por Tomografía Computarizada/métodos , Enfermedad Crónica , Anciano , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/fisiopatología , Aneurisma de la Aorta Torácica/complicaciones , Angiografía por Resonancia Magnética/métodos
3.
J Cardiovasc Magn Reson ; 26(1): 100992, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38211655

RESUMEN

BACKGROUND: The measurement of aortic dimensions and their evolution are key in the management of patients with aortic diseases. Manual assessment, the current guideline-recommended method and clinical standard, is subjective, poorly reproducible, and time-consuming, limiting the capacity to track aortic growth in everyday practice. Aortic geometry mapping (AGM) via image registration of serial computed tomography angiograms outperforms manual assessment, providing accurate and reproducible 3D maps of aortic diameter and growth rate. This observational study aimed to evaluate the accuracy and reproducibility of AGM on non-gated contrast-enhanced (CE-) and cardiac- and respiratory-gated (GN-) magnetic resonance angiographies (MRA). METHODS: Patients with thoracic aortic disease followed with serial CE-MRA (n = 30) or GN-MRA (n = 15) acquired at least 1 year apart were retrospectively and consecutively identified. Two independent observers measured aortic diameters and growth rates (GR) manually at several thoracic aorta reference levels and with AGM. Agreement between manual and AGM measurements and their inter-observer reproducibility were compared. Reproducibility for aortic diameter and GR maps assessed with AGM was obtained. RESULTS: Mean follow-up was 3.8 ± 2.3 years for CE- and 2.7 ± 1.6 years for GN-MRA. AGM was feasible in the 93% of CE-MRA pairs and in the 100% of GN-MRA pairs. Manual and AGM diameters showed excellent agreement and inter-observer reproducibility (ICC>0.9) at all anatomical levels. Agreement between manual and AGM GR was more limited, both in the aortic root by GN-MRA (ICC=0.47) and in the thoracic aorta, where higher accuracy was obtained with GN- than with CE-MRA (ICC=0.55 vs 0.43). The inter-observer reproducibility of GR by AGM was superior compared to manual assessment, both with CE- (thoracic: ICC= 0.91 vs 0.51) and GN-MRA (root: ICC=0.84 vs 0.52; thoracic: ICC=0.93 vs 0.60). AGM-based 3D aortic size and growth maps were highly reproducible (median ICC >0.9 for diameters and >0.80 for GR). CONCLUSION: Mapping aortic diameter and growth on MRA via 3D image registration is feasible, accurate and outperforms the current manual clinical standard. This technique could broaden the possibilities of clinical and research evaluation of patients with aortic thoracic diseases.


Asunto(s)
Aorta Torácica , Enfermedades de la Aorta , Medios de Contraste , Imagenología Tridimensional , Angiografía por Resonancia Magnética , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Humanos , Reproducibilidad de los Resultados , Masculino , Femenino , Estudios Retrospectivos , Persona de Mediana Edad , Aorta Torácica/diagnóstico por imagen , Anciano , Medios de Contraste/administración & dosificación , Enfermedades de la Aorta/diagnóstico por imagen , Técnicas de Imagen Sincronizada Respiratorias , Adulto , Factores de Tiempo , Interpretación de Imagen Asistida por Computador , Técnicas de Imagen Sincronizada Cardíacas
4.
Clin Exp Rheumatol ; 42(2): 309-315, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38488096

RESUMEN

OBJECTIVES: There is an increasing interest in knowing whether patients with antisynthetase syndrome (ASSD) may have silent myocardial interstitial involvement. Mapping techniques in cardiac magnetic resonance (CMR) can detect subclinical myocardial involvement. The purpose of this study was to identify alterations in multiparametric CMR in ASSD patients without overt cardiac involvement. METHODS: Patients diagnosed with ASSD underwent a CMR along with the standard clinical workup, investigation of specific and associated myositis antibodies, and high-resolution chest CT. The CMR protocol includes routine morphologic, functional, and late gadolinium enhancement sequences in standard cardiac planes, as well as native T1 and T2 mapping sequences and extracellular volume (ECV) calculation. RESULTS: Twenty-five patients were included in this study (56% women; median age 56.3 years). Three patients were considered in the acute phase at the time of inclusion. Eight patients (32%) showed pathological findings in CMR (6 stable disease, 2 acute phase). Elevated T1, T2 and ECV mapping values were found in 20% (5/25), 17% (4/25) and 24% (6/25) of the group, respectively. Two patients in the acute phase had increased values of both T2 and ECV. CONCLUSIONS: Subclinical myocardial involvement in ASSD is not rare (32%) although its clinical significance is uncertain. Myocardial oedema (T2) was the most frequent finding, followed by increased T1 and/or ECV values likely signalling interstitial fibrosis. Of note, patients in the acute phase showed elevated T2 values.


Asunto(s)
Medios de Contraste , Miositis , Humanos , Femenino , Persona de Mediana Edad , Masculino , Imagen por Resonancia Cinemagnética/métodos , Fibrosis , Gadolinio , Miocardio/patología , Miositis/diagnóstico por imagen , Miositis/patología , Valor Predictivo de las Pruebas
5.
J Cardiovasc Magn Reson ; 24(1): 20, 2022 03 28.
Artículo en Inglés | MEDLINE | ID: mdl-35346239

RESUMEN

BACKGROUND: Patency of the false lumen in chronic aortic dissection (AD) is associated with aortic dilation and long-term aortic events. However, predictors of adverse outcomes in this population are limited. The aim of this study was to evaluate the relationship between aortic growth rate and false lumen flow dynamics and biomechanics in patients with chronic, patent AD. METHODS: Patients with a chronic AD with patent false lumen in the descending aorta and no genetic connective tissue disorder underwent an imaging follow-up including a contrast-enhanced 4D flow cardiovascular magnetic resonance (CMR) protocol and two consecutive computed tomography angiograms (CTA) acquired at least 1 year apart. A comprehensive analysis of anatomical features (including thrombus quantification), and false lumen flow dynamics and biomechanics (pulse wave velocity) was performed. RESULTS: Fifty-four consecutive patients with a chronic, patent false lumen in the descending aorta were included (35 surgically-treated type A AD with residual tear and 19 medically-treated type B AD). Median follow-up was 40 months. The in-plane rotational flow, pulse wave velocity and the percentage of thrombus in the false lumen were positively related to aortic growth rate (p = 0.006, 0.017, and 0.037, respectively), whereas wall shear stress showed a trend for a positive association (p = 0.060). These results were found irrespectively of the type of AD. CONCLUSIONS: In patients with chronic AD and patent false lumen of the descending aorta, rotational flow, pulse wave velocity and wall shear stress are positively related to aortic growth rate, and should be implemented in the follow-up algorithm of these patients. Further prospective studies are needed to confirm if the assessment of these parameters helps to identify patients at higher risk of adverse clinical events.


Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Rigidez Vascular , Disección Aórtica/diagnóstico por imagen , Humanos , Espectroscopía de Resonancia Magnética , Valor Predictivo de las Pruebas , Análisis de la Onda del Pulso
6.
J Nucl Cardiol ; 29(1): 72-82, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32458331

RESUMEN

BACKGROUND: Diabetes mellitus is an independent risk factor in the development of coronary artery disease (CAD), myocardial infarction (MI), and cardiac death (CD). The major adverse cardiac events (MACEs) between men and women in diabetic patients stratified by CAD (previous MI and/or coronary revascularization, CR) were analyzed. METHODS AND RESULTS: A cohort of 1327 consecutive diabetic patients (age 66.5 ± 9 years) underwent gated SPECT (single-photon emission computed tomography). During a mean follow-up of 4.7 ± 2.2 years post gated SPECT, MACEs (non-fatal MI, CD, and late CR) were evaluated according to gender stratified by CAD. Among diabetic patients without known CAD (N = 731), men had more MACEs (sHR 1.9;95%CI 1.2-3.2) than women. Among diabetic patients with known CAD (N = 596), there was no difference in MACEs in diabetic men and women (sHR 1.15;95%CI 0.73-1.8). Diabetic women with known CAD (n = 143) were the group with the highest risk (sHR 1.7; P = .041) for MACEs (4.5% MACEs/year, [95%CI 3.1%-6.4%]), compared to the remaining diabetic patients (N = 1184) (3% MACEs/year, [95%CI 2.6%-3.5%]). CONCLUSIONS: The prognosis of diabetic patients for MACEs is different in men and women stratified by CAD. The worst prognosis for MACEs occurs in women with known CAD.


Asunto(s)
Enfermedad de la Arteria Coronaria , Diabetes Mellitus , Infarto del Miocardio , Anciano , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Diabetes Mellitus/diagnóstico por imagen , Diabetes Mellitus/epidemiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/diagnóstico por imagen , Pronóstico , Factores de Riesgo , Factores Sexuales , Tomografía Computarizada de Emisión de Fotón Único
7.
J Cardiovasc Electrophysiol ; 30(3): 448-456, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30556327

RESUMEN

BACKGROUND: Radiofrequency ablation (RF) of ventricular tachycardia (VT) due to intramural foci has a high recurrence rate. Several techniques, such as bipolar ablation, irrigated needle ablation catheter, and retrograde coronary venous ethanol ablation have been suggested. Transarterial coronary ethanol ablation (TCEA) can also be effective. We present a case series of TCEA guided with preprocedural imaging to correlated coronary arteries and the intramural substrate. METHODS AND RESULTS: We present three consecutive patients with previous RF of septal VT (100% male; age, 72.6 ± 11.01 years; two patients with hypertrophic cardiomyopathy, one with mechanical aortic valve prosthesis) that underwent TCEA. Cardiac magnetic resonance was performed in two patients and cardiac CT in all patients. Correlation of septal arteries with intramural substrate was analyzed before the procedure so TCEA was attempted according to this analysis. After last TCEA (6.3 ± 2.08 months) the VT burden was reduced in all patients (sum of all implantable cardioverter-defibrillator therapies [antitachycardia pacing and shock] before and after TCEA, 15.8 ± 3.73 vs 0.97 ± 0.63 therapies/month; P = 0.02). No complications occurred during TCEA. CONCLUSIONS: TCEA completely guided with previous magnetic resonance imaging and computed tomography scan to select the coronary artery in relation to the substrate seems to be feasible as an alternative strategy in cases of intramural VT refractory to RF ablation.


Asunto(s)
Técnicas de Ablación , Angiografía por Tomografía Computarizada , Angiografía Coronaria/métodos , Vasos Coronarios/diagnóstico por imagen , Etanol/administración & dosificación , Imagen por Resonancia Cinemagnética , Tomografía Computarizada Multidetector , Taquicardia Ventricular/cirugía , Tabique Interventricular/cirugía , Anciano , Anciano de 80 o más Años , Humanos , Inyecciones Intraarteriales , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Taquicardia Ventricular/diagnóstico por imagen , Taquicardia Ventricular/fisiopatología , Resultado del Tratamiento , Tabique Interventricular/diagnóstico por imagen , Tabique Interventricular/fisiopatología
10.
Circulation ; 132(12): 1113-26, 2015 Sep 22.
Artículo en Inglés | MEDLINE | ID: mdl-26276890

RESUMEN

BACKGROUND: The diagnosis of infective endocarditis (IE) in prosthetic valves and intracardiac devices is challenging because both the modified Duke criteria (DC) and echocardiography have limitations in this population. The added value of (18)F-fluorodeoxyglucose ((18)F-FDG) positron emission tomography (PET)/computed tomography (CT) and (18)F-FDG PET/CT angiography (PET/CTA) was evaluated in this complex scenario at a referral center with a multidisciplinary IE unit. METHODS AND RESULTS: Ninety-two patients admitted to our hospital with suspected prosthetic valve or cardiac device IE between November 2012 and November 2014 were prospectively included. All patients underwent echocardiography and PET/CT, and 76 had cardiac CTA. PET/CT and echocardiography findings were evaluated and compared, with concordant results in 54% of cases (κ=0.23). Initial diagnoses with DC at admission, PET/CT, and DC+PET/CT were compared with the final diagnostic consensus reached by the IE Unit. DC+PET/CT enabled reclassification of 90% of cases initially classified as possible IE with DC and provided a conclusive diagnosis (definite/rejected) in 95% of cases. Sensitivity, specificity, and positive and negative predictive values were 52%, 94.7%, 92.9%, and 59.7% for DC; 87%, 92.1%, 93.6%, and 84.3% for PET/CT; and 90.7%, 89.5%, 92%, and 87.9% for DC+PET/CT. Use of PET/CTA yielded even better diagnostic performance values than PET/nonenhanced CT (91%, 90.6%, 92.8%, and 88.3% versus 86.4%, 87.5%, 90.2%, and 82.9%) and substantially reduced the rate of doubtful cases from 20% to 8% (P<0.001). DC+PET/CTA reclassified an additional 20% of cases classified as possible IE with DC+PET/nonenhanced CT. In addition, PET/CTA enabled detection of a significantly larger number of anatomic lesions associated with active endocarditis than PET/nonenhanced CT (P=0.006) or echocardiography (P<0.001). CONCLUSIONS: (18)F-FDG PET/CT improves the diagnostic accuracy of the modified DC in patients with suspected IE and prosthetic valves or cardiac devices. PET/CTA yielded the highest diagnostic performance and provided additional diagnostic benefits.


Asunto(s)
Angiografía/métodos , Desfibriladores Implantables/microbiología , Endocarditis/diagnóstico , Prótesis Valvulares Cardíacas/microbiología , Marcapaso Artificial/microbiología , Tomografía de Emisión de Positrones/métodos , Tomografía Computarizada por Rayos X/métodos , Anciano , Arritmias Cardíacas/terapia , Ecocardiografía , Endocarditis/diagnóstico por imagen , Femenino , Fluorodesoxiglucosa F18 , Enfermedades de las Válvulas Cardíacas/cirugía , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/diagnóstico , Valor Predictivo de las Pruebas , Estudios Prospectivos , Estudios Retrospectivos , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA