Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Eur Radiol ; 32(12): 8339-8349, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35727321

RESUMEN

OBJECTIVES: Portal hypertension (PH) is associated with complications such as ascites and esophageal varices and is typically diagnosed through invasive hepatic venous pressure gradient (HVPG) measurement, which is not widely available. In this study, we aim to assess the diagnostic performance of 2D/3D MR elastography (MRE) and shear wave elastography (SWE) measures of liver and spleen stiffness (LS and SS) and spleen volume, to noninvasively diagnose clinically significant portal hypertension (CSPH) using HVPG measurement as the reference. METHODS: In this prospective study, patients with liver disease underwent 2D/3D MRE and SWE of the liver and spleen, as well as HVPG measurement. The correlation between MRE/SWE measures of LS/SS and spleen volume with HVPG was assessed. ROC analysis was used to determine the utility of MRE, SWE, and spleen volume for diagnosing CSPH. RESULTS: Thirty-six patients (M/F 22/14, mean age 55 ± 14 years) were included. Of the evaluated parameters, 3D MRE SS had the strongest correlation with HVPG (r = 0.686, p < 0.001), followed by 2D MRE SS (r = 0.476, p = 0.004). 3D MRE SS displayed the best performance for diagnosis of CSPH (AUC = 0.911) followed by 2D MRE SS (AUC = 0.845) and 3D MRE LS (AUC = 0.804). SWE SS showed poor performance for diagnosis of CSPH (AUC = 0.583) while spleen volume was a fair predictor (AUC = 0.738). 3D MRE SS was significantly superior to SWE LS/SS (p ≤ 0.021) for the diagnosis of CSPH. CONCLUSION: SS measured with 3D MRE outperforms SWE for the diagnosis of CSPH. SS appears to be a useful biomarker for assessing PH severity. These results need further validation. KEY POINTS: • Spleen stiffness measured with 2D and 3D MR elastography correlates significantly with hepatic venous pressure gradient measurement. • Spleen stiffness measured with 3D MR elastography demonstrates excellent performance for the diagnosis of clinically significant portal hypertension (AUC 0.911). • Spleen stiffness measured with 3D MR elastography outperforms liver and spleen stiffness measured with shear wave elastography for diagnosis of clinically significant portal hypertension.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Hipertensión Portal , Humanos , Adulto , Persona de Mediana Edad , Anciano , Diagnóstico por Imagen de Elasticidad/métodos , Estudios Prospectivos , Cirrosis Hepática/complicaciones , Hipertensión Portal/complicaciones , Hipertensión Portal/diagnóstico por imagen , Hipertensión Portal/patología , Presión Portal , Hígado/patología
2.
J Magn Reson Imaging ; 54(3): 904-909, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-33644967

RESUMEN

BACKGROUND: Prior imaging studies characterizing lumbar arachnoiditis have been based on small sample numbers and have reported inconsistent results. PURPOSE: To review the different imaging patterns of lumbosacral arachnoiditis, their significance, and clinical implications. STUDY TYPE: Retrospective. POPULATION: A total of 96 patients (43 women; average age 61.3 years) with imaging findings of arachnoiditis (postsurgical: N = 49; degenerative: N = 29; vertebral fracture: N = 6; epidural and subdural hemorrhage: N = 3, infectious: N= 1; other: N = 8) from January 2009 to April 2018. FIELD STRENGTH/SEQUENCE: Sagittal and axial T2-weighted Turbo Spin Echo at 1.5 T and 3 T. ASSESSMENT: Chart review was performed to assess the cause of arachnoiditis, and imaging was reviewed by two musculoskeletal and three neurology radiologists, blinded to the clinical data and to each other's imaging interpretation. Previous classification included a three-group system based on the appearance of the nerve roots on T2-weighted images. A fourth group was added in our review as "nonspecified" and was proposed for indeterminate imaging findings that did not fall into the classical groups. The presence/absence of synechiae/fibrous bands that distort the nerve roots and of spinal canal stenosis was also assessed. STATISTICAL TESTS: The kappa score was used to assess agreement between readers for both classification type and presence/absence of synechiae. RESULTS: Postsurgical (51%) and degenerative changes (30%) were the most common etiologies. About 7%-55% of arachnoiditis were classified as group 4. There was very poor classification agreement between readers (kappa score 0.051). There was also poor interreader agreement for determining the presence of synechiae (kappa 0.18) with, however, strong interreader agreement for the presence of synechia obtained between the most experienced readers (kappa 0.89). DATA CONCLUSION: This study demonstrated the lack of consensus and clarity in the classification system of lumbar arachnoiditis. The presence of synechia has high interreader agreement only among most experienced readers and promises to be a useful tool in assessing arachnoiditis. EVIDENCE LEVEL: 3 TECHNICAL EFFICACY: Stage 2.


Asunto(s)
Aracnoiditis , Aracnoiditis/diagnóstico por imagen , Femenino , Humanos , Vértebras Lumbares , Imagen por Resonancia Magnética , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios Retrospectivos
3.
Eur Radiol ; 31(7): 4804-4812, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33411050

RESUMEN

OBJECTIVES: To assess the performance of gadoxetate dynamic contrast-enhanced (DCE) MRI of the liver and spleen for noninvasive diagnosis of portal hypertension (PH). METHODS: Thirty-five patients (M/F 22/13, mean age 55 years) with chronic liver disease who underwent hepatic venous pressure gradient (HVPG) measurements were prospectively enrolled in this IRB-approved study. All patients underwent multiparametric MRI including gadoxetate DCE-MRI acquisition. Model-based and model-free DCE-MRI analyses were performed. The correlation between DCE-MRI parameters and HVPG was assessed. ROC analysis was employed to determine the diagnostic performance of DCE-MRI parameters alone and in combination for prediction of PH and clinically significant (CS)PH (HVPG > 5 and ≥ 10 mmHg, respectively). RESULTS: Mean HVPG was 7.0 ± 5.0 mmHg (range 0-18 mmHg). Twenty-one (60%) patients had PH, of whom 9 had CSPH. Modeled liver uptake fraction fi and uptake rate ki and model-free parameters liver upslope and uptake were all significantly negatively correlated with HVPG (r range - 0.490 to - 0.398, p value range 0.003-0.018), while spleen interstitial fraction ve was significantly positively correlated with HVPG (r = 0.336, p = 0.048). For PH diagnosis, liver ki showed the best diagnostic performance with an AUC, sensitivity, and specificity of 0.74 (confidence interval (CI) 0.57-0.91), 71.4%, and 78.6%. The combination of liver ki and spleen ve was selected as the best classifier for diagnosis of CSPH with an AUC, sensitivity, and specificity of 0.87 (CI 0.75-0.99), 100%, and 73.1%. CONCLUSIONS: Our results demonstrate the potential utility of hepatocyte uptake parameters and spleen interstitial fraction obtained with gadoxetate DCE-MRI for the diagnosis of PH and CSPH. KEY POINTS: • Liver uptake and spleen interstitial fraction estimates from gadoxetate DCE-MRI are significantly correlated with portal pressure measurements. • Liver uptake rate shows good diagnostic performance for the diagnosis of portal hypertension. • The combination of liver uptake rate with spleen interstitial fraction exhibits excellent diagnostic performance for the diagnosis of clinically significant portal hypertension.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Hipertensión Portal , Humanos , Hipertensión Portal/diagnóstico por imagen , Hígado/diagnóstico por imagen , Cirrosis Hepática , Imagen por Resonancia Magnética , Persona de Mediana Edad , Presión Portal , Bazo/diagnóstico por imagen
4.
Eur Radiol ; 31(12): 9306-9315, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34043055

RESUMEN

OBJECTIVES: (1) To assess the quality of the arterial input function (AIF) during dynamic contrast-enhanced (DCE) MRI of the liver and (2) to quantify perfusion parameters of hepatocellular carcinoma (HCC) and liver parenchyma during the first 3 min post-contrast injection with DCE-MRI using gadoxetate disodium compared to gadobenate dimeglumine (Gd-BOPTA) in different patient populations. METHODS: In this prospective study, we evaluated 66 patients with 83 HCCs who underwent DCE-MRI, using gadoxetate disodium (group 1, n = 28) or Gd-BOPTA (group 2, n = 38). AIF qualitative and quantitative features were assessed. Perfusion parameters (based on the initial 3 min post-contrast) were extracted in tumours and liver parenchyma, including model-free parameters (time-to-peak enhancement (TTP), time-to-washout) and modelled parameters (arterial flow (Fa), portal venous flow (Fp), total flow (Ft), arterial fraction, mean transit time (MTT), distribution volume (DV)). In addition, lesion-to-liver contrast ratios (LLCRs) were measured. Fisher's exact tests and Mann-Whitney U tests were used to compare the two groups. RESULTS: AIF quality, modelled and model-free perfusion parameters in HCC were similar between the 2 groups (p = 0.054-0.932). Liver parenchymal flow was lower and liver enhancement occurred later in group 1 vs group 2 (Fp, p = 0.002; Ft, p = 0.001; TTP, MTT, all p < 0.001), while there were no significant differences in tumour LLCR (max. positive LLCR, p = 0.230; max. negative LLCR, p = 0.317). CONCLUSION: Gadoxetate disodium provides comparable AIF quality and HCC perfusion parameters compared to Gd-BOPTA during dynamic phases. Despite delayed and decreased liver enhancement with gadoxetate disodium, LLCRs were equivalent between contrast agents, indicating similar tumour conspicuity. KEY POINTS: • Arterial input function quality, modelled, and model-free dynamic parameters measured in hepatocellular carcinoma are similar in patients receiving gadoxetate disodium or gadobenate dimeglumine during the first 3 min post injection. • Gadoxetate disodium and gadobenate dimeglumine show similar lesion-to-liver contrast ratios during dynamic phases in patients with HCC. • There is lower portal and lower total hepatic flow and longer hepatic mean transit time and time-to-peak with gadoxetate disodium compared to gadobenate dimeglumine.


Asunto(s)
Carcinoma Hepatocelular , Neoplasias Hepáticas , Compuestos Organometálicos , Carcinoma Hepatocelular/diagnóstico por imagen , Medios de Contraste , Gadolinio DTPA , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Imagen por Resonancia Magnética , Meglumina/análogos & derivados , Perfusión , Estudios Prospectivos
5.
Surg Endosc ; 34(9): 4101-4109, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-31602515

RESUMEN

BACKGROUND: Transanal total mesorectal excision (taTME) is a surgical approach for low rectal cancer with a learning curve estimated at 40-50 cases. The experience among taTME surgeons beyond their learning curve is limited. METHODS: A retrospective analysis of all taTME cases performed for rectal cancer at two tertiary care hospitals from 2014 to 2019 was conducted. Transanal surgeons had previously performed > 50 taTME cases. Demographic, perioperative, and short-term outcomes were analyzed. RESULTS: Among 54 taTME patients, 74.1% were male and 27.8% had a BMI ≥ 30. Tumors were stage I (8), II (13), III (29), and IV (4). Complex cases included 4 local recurrences, 4 prior liver resections, and 2 with prior prostate cancer. Thirty tumors were located ≤ 6 cm from the anal verge. On staging MRI, 12 had a positive predicted circumferential radial margin (+CRM), and 4 had internal anal sphincter involvement (+IAS). Forty-seven patients received neoadjuvant therapy. A 2-team approach was used in 51 patients with laparoscopic (83.3%) or robotic (16.7%) abdominal assistance with a 9.2% conversion rate. Low anterior resection with sphincter salvage was achieved in 87% with 8 patients requiring intersphincteric resection. Anastomoses were hand-sewn in 57.4% and all patients were diverted. Median LOS was 5 days with a 42.6% 30-day morbidity rate and 3 postoperative mortalities (ARDS, pulmonary embolism and pseudomembranous colitis). Complete and near complete TME grade was achieved in 94.4% with a 3.7% rate of +CRM. At a median follow-up of 28 months, local and distant recurrence rates were 3.9% and 17.6%, respectively, with no cancer-related mortality. CONCLUSION: Indications for taTME at experienced centers have expanded to include complex reoperative cases, local recurrences, metastatic cancer, and tumors with threatened CRM or IAS with evidence of post-treatment tumor regression. In the latter cases, taTME achieves good short-term outcomes and may facilitate R0 resection.


Asunto(s)
Curva de Aprendizaje , Neoplasias del Recto/cirugía , Recto/cirugía , Cirugía Endoscópica Transanal , Anciano , Canal Anal/cirugía , Femenino , Humanos , Laparoscopía , Tiempo de Internación , Imagen por Resonancia Magnética , Masculino , Márgenes de Escisión , Persona de Mediana Edad , Recurrencia Local de Neoplasia/cirugía , Estadificación de Neoplasias , Complicaciones Posoperatorias , Neoplasias del Recto/diagnóstico por imagen , Neoplasias del Recto/patología , Estudios Retrospectivos , Cirugía Endoscópica Transanal/efectos adversos , Resultado del Tratamiento
6.
Abdom Radiol (NY) ; 49(3): 791-800, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38150143

RESUMEN

PURPOSE: To assess the role of pretreatment multiparametric (mp)MRI-based radiomic features in predicting pathologic complete response (pCR) of locally advanced rectal cancer (LARC) to neoadjuvant chemoradiation therapy (nCRT). METHODS: This was a retrospective dual-center study including 98 patients (M/F 77/21, mean age 60 years) with LARC who underwent pretreatment mpMRI followed by nCRT and total mesorectal excision or watch and wait. Fifty-eight patients from institution 1 constituted the training set and 40 from institution 2 the validation set. Manual segmentation using volumes of interest was performed on T1WI pre-/post-contrast, T2WI and diffusion-weighted imaging (DWI) sequences. Demographic information and serum carcinoembryonic antigen (CEA) levels were collected. Shape, 1st and 2nd order radiomic features were extracted and entered in models based on principal component analysis used to predict pCR. The best model was obtained using a k-fold cross-validation method on the training set, and AUC, sensitivity and specificity for prediction of pCR were calculated on the validation set. RESULTS: Stage distribution was T3 (n = 79) or T4 (n = 19). Overall, 16 (16.3%) patients achieved pCR. Demographics, MRI TNM stage, and CEA were not predictive of pCR (p range 0.59-0.96), while several radiomic models achieved high diagnostic performance for prediction of pCR (in the validation set), with AUCs ranging from 0.7 to 0.9, with the best model based on high b-value DWI demonstrating AUC of 0.9 [95% confidence intervals: 0.67, 1], sensitivity of 100% [100%, 100%], and specificity of 81% [66%, 96%]. CONCLUSION: Radiomic models obtained from pre-treatment MRI show good to excellent performance for the prediction of pCR in patients with LARC, superior to clinical parameters and CEA. A larger study is needed for confirmation of these results.


Asunto(s)
Imágenes de Resonancia Magnética Multiparamétrica , Neoplasias del Recto , Humanos , Persona de Mediana Edad , Estudios Retrospectivos , Terapia Neoadyuvante/métodos , Antígeno Carcinoembrionario , Radiómica , Resultado del Tratamiento , Quimioradioterapia/métodos , Imagen por Resonancia Magnética/métodos , Neoplasias del Recto/diagnóstico por imagen , Neoplasias del Recto/terapia
7.
Abdom Radiol (NY) ; 2024 Mar 12.
Artículo en Inglés | MEDLINE | ID: mdl-38467854

RESUMEN

OBJECTIVES: To evaluate radiomics features' reproducibility using inter-package/inter-observer measurement analysis in renal masses (RMs) based on MRI and to employ machine learning (ML) models for RM characterization. METHODS: 32 Patients (23M/9F; age 61.8 ± 10.6 years) with RMs (25 renal cell carcinomas (RCC)/7 benign masses; mean size, 3.43 ± 1.73 cm) undergoing resection were prospectively recruited. All patients underwent 1.5 T MRI with T2-weighted (T2-WI), diffusion-weighted (DWI)/apparent diffusion coefficient (ADC), and pre-/post-contrast-enhanced T1-weighted imaging (T1-WI). RMs were manually segmented using volume of interest (VOI) on T2-WI, DWI/ADC, and T1-WI pre-/post-contrast imaging (1-min, 3-min post-injection) by two independent observers using two radiomics software packages for inter-package and inter-observer assessments of shape/histogram/texture features common to both packages (104 features; n = 26 patients). Intra-class correlation coefficients (ICCs) were calculated to assess inter-observer and inter-package reproducibility of radiomics measurements [good (ICC ≥ 0.8)/moderate (ICC = 0.5-0.8)/poor (ICC < 0.5)]. ML models were employed using reproducible features (between observers and packages, ICC > 0.8) to distinguish RCC from benign RM. RESULTS: Inter-package comparisons demonstrated that radiomics features from T1-WI-post-contrast had the highest proportion of good/moderate ICCs (54.8-58.6% for T1-WI-1 min), while most features extracted from T2-WI, T1-WI-pre-contrast, and ADC exhibited poor ICCs. Inter-observer comparisons found that radiomics measurements from T1-WI pre/post-contrast and T2-WI had the greatest proportion of features with good/moderate ICCs (95.3-99.1% T1-WI-post-contrast 1-min), while ADC measurements yielded mostly poor ICCs. ML models generated an AUC of 0.71 [95% confidence interval = 0.67-0.75] for diagnosis of RCC vs. benign RM. CONCLUSION: Radiomics features extracted from T1-WI-post-contrast demonstrated greater inter-package and inter-observer reproducibility compared to ADC, with fair accuracy for distinguishing RCC from benign RM. CLINICAL RELEVANCE: Knowledge of reproducibility of MRI radiomics features obtained on renal masses will aid in future study design and may enhance the diagnostic utility of radiomics models for renal mass characterization.

8.
J Am Coll Radiol ; 19(4): 502-512, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35248523

RESUMEN

BACKGROUND: Abbreviated MRI (AMRI), proposed as an alternative imaging modality for hepatocellular carcinoma screening, provides higher sensitivity than ultrasound. It is, however, unknown how patients weigh the higher sensitivity of AMRI against its higher cost and potentially less desirable testing experience. PURPOSE: To assess patient preferences for hepatocellular carcinoma screening test attributes including sensitivity, false-positive rate, test-related anxiety, cost, and need for intravenous catheterization and contrast use, measured by choice-based conjoint analysis. MATERIALS AND METHODS: This was an ancillary study to two prospective dual-center studies designed to compare the hepatocellular carcinoma detection rates by ultrasound versus AMRI. Of the 135 eligible participants, 106 (median age 63, range 25-85; 56% male) completed the choice-based conjoint analysis survey and were included in this substudy. Participants' preference for individual screening test attributes was assessed using a 12-item, web-based choice-based conjoint analysis survey administered in person at the screening visit. Conjoint analyses software and hierarchical Bayes random-effects logit model were used to calculate the relative importance of each attribute. RESULTS: The most important attribute driving patient preferences was higher test sensitivity (importance score 39.8%), followed by lower cost (importance score 22.8%) and lower false-positive rate (importance score 19.4%). The overall estimated participants' preference for ultrasound and AMRI were similar when assuming the same specificity for both modalities. CONCLUSION: Higher screening test sensitivity and lower cost were the leading patient preference drivers. This study has important implications for understanding patient preferences for specific screening test characteristics as potential determinants of adherence.


Asunto(s)
Carcinoma Hepatocelular , Neoplasias Hepáticas , Teorema de Bayes , Carcinoma Hepatocelular/diagnóstico por imagen , Femenino , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Prioridad del Paciente , Estudios Prospectivos , Encuestas y Cuestionarios
9.
J Crohns Colitis ; 15(6): 1009-1018, 2021 Jun 22.
Artículo en Inglés | MEDLINE | ID: mdl-33319236

RESUMEN

BACKGROUND AND AIMS: Current consensus recommendations define small bowel strictures [SBS] in Crohn's disease [CD] on imaging as luminal narrowing with unequivocal upstream bowel dilation. The aim of this study was to [1] evaluate the performance of cross-sectional imaging for SBS diagnosis in CD using luminal narrowing with upstream SB dilation and luminal narrowing with or without upstream dilation, and [2] compare the diagnostic performance of computed tomography [CT] and magnetic resonance enterography [MRE] for SBS diagnosis. METHODS: In total, 111 CD patients [81 with pathologically confirmed SBS, 30 controls] who underwent CT and/or MRE were assessed. Two radiologists [R1, R2] blinded to pathology findings independently assessed the presence of luminal narrowing and upstream SB dilation. Statistical analysis was performed for [1] luminal narrowing with or without SB upstream dilation ['possible SBS'], and [2] luminal narrowing with upstream SB dilation ≥3 cm ['definite SBS']. RESULTS: Sensitivity for detecting SBS was significantly higher using 'possible SBS' [R1, 82.1%; R2, 77.9%] compared to 'definite SBS' [R1, 62.1%; R2, 65.3%; p < 0.0001] with equivalent specificity [R1, 96.7%; R2, 93.3%; p > 0.9]. Using the criterion 'possible SBS', sensitivity/specificity were equivalent between CT [R1, 87.3%/93.3%; R2, 83.6%/86.7%] and MRE [R1, 75.0%/100%; R2: 70.0%/100%]. Using the criterion 'definite SBS', CT showed significantly higher sensitivity [78.2%] compared to MRE [40.0%] for R1 but not R2 with similar specificities [CT, 86.7-93.3%; MRE, 100%]. CONCLUSION: SBS can be diagnosed using luminal narrowing alone without the need for upstream dilation. CT and MRE show similar diagnostic performance for SBS diagnosis using luminal narrowing with or without upstream dilation.


Asunto(s)
Enfermedad de Crohn , Obstrucción Intestinal , Intestino Delgado/diagnóstico por imagen , Imagen por Resonancia Magnética , Tomografía Computarizada por Rayos X , Adulto , Investigación sobre la Eficacia Comparativa , Constricción Patológica/diagnóstico por imagen , Constricción Patológica/etiología , Enfermedad de Crohn/complicaciones , Enfermedad de Crohn/diagnóstico , Enfermedad de Crohn/fisiopatología , Femenino , Humanos , Obstrucción Intestinal/diagnóstico , Obstrucción Intestinal/etiología , Intestino Delgado/patología , Intestino Delgado/fisiopatología , Imagen por Resonancia Magnética/métodos , Imagen por Resonancia Magnética/estadística & datos numéricos , Masculino , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X/métodos , Tomografía Computarizada por Rayos X/estadística & datos numéricos , Estados Unidos/epidemiología
10.
Am J Prev Med ; 44(3 Suppl 3): S274-81, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23415193

RESUMEN

BACKGROUND: Childhood obesity has increased substantially among Latino children, placing them at risk for its related health consequences. Limited attention has been given to childhood obesity among Latino migrant farm-working communities. PURPOSE: To examine, within a migrant farm-working community, (1) the prevalence of obesity among Latino children and parents and (2) parent perceptions of children's weight status and intentions to take corrective action. METHODS: Structured interviews were completed with the parents of 495 children seen for well-child office visits in the pediatric department of a community health center during a 15-month period between 2010 and 2011. Medical chart reviews were completed for each child participant. RESULTS: Forty-seven percent of the children were overweight (20%) or obese (27%). In comparison to preschool-aged children, those in elementary and middle school were more likely to be obese. In elementary school, girls were more likely than boys to be overweight or obese. Child obesity was associated with parent obesity. Parental concern about their child's weight was associated with child obesity but not with child overweight. Parental concern was associated with parent intention to address the child's weight, particularly in older children. Analysis was completed in 2012. CONCLUSIONS: Interventions are needed that address both childhood obesity and parent weight status among Latino migrant farmworkers. Prevention programs that address the weight status of Latino children who are overweight, but not necessarily obese, are also needed, as their parents tend to be no more concerned about a child who is overweight than one who is normal weight.


Asunto(s)
Agricultura , Emigrantes e Inmigrantes/psicología , Hispánicos o Latinos , Obesidad/etnología , Padres/psicología , Adolescente , Adulto , Índice de Masa Corporal , Niño , Preescolar , Femenino , Humanos , Masculino , Sobrepeso/etnología , Percepción , Prevalencia , Factores Socioeconómicos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA