Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Telemed J E Health ; 29(11): 1591-1600, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-36976779

RESUMEN

Introduction: Teledentistry (TD) can offer a wide range of possibilities in the field of oral medicine. Oral potentially malignant disorders (OPMDs) are hard to detect, and even harder to diagnose correctly. With the help of TD, OPMDs can be detected and diagnosed by a remote specialist. Our aim was to investigate whether TD could provide a reliable diagnostic method compared with clinical oral examination (COE) in the diagnosis of OPMDs. Methods: A systematic search was conducted in three databases (Medline, EMBASE, CENTRAL) until November 2021. We included studies that compared telediagnosis and COE, both made by experts. Pooled specificity and sensitivity were calculated and visualized on a two-dimensional plot. Risk of bias was assessed using the QUADAS-2 tool, and the level of evidence is shown with the Grades of Recommendation, Assessment, Development and Evaluation (GRADE) tool. Results: Of the 7,608 studies, 13 were included in the qualitative and 9 in the quantitative synthesis. Using TD tools in the detection of oral lesions (OLs) showed high specificity (0.92 confidence interval [95% CI] = 0.59-0.99) and sensitivity (0.93 95% CI = 0.17-1.00). In the differential diagnosis of lesions, we found high sensitivity and specificity (0.942 95% CI = 0.826-0.982 and 0.982 95% CI = 0.913-0.997), respectively. We summarized the available data on time-effectiveness, screening person, referral decision, and technical settings. Conclusion: Detecting OLs with TD tools might lead to earlier diagnosis, treatment, and stricter follow-up of OPMD. TD may offer a great substitution for COE in the diagnosis of OLs, and thus, fewer referrals could be made to special care, resulting in a greater number of treated OPMDs.


Asunto(s)
Diagnóstico Bucal , Examen Físico , Humanos , Sensibilidad y Especificidad , Examen Físico/métodos
2.
J Prosthet Dent ; 2023 Jun 21.
Artículo en Inglés | MEDLINE | ID: mdl-37349158

RESUMEN

STATEMENT OF PROBLEM: Technical complication rates of standard metal-ceramic implant-supported posterior restorations are relatively high. Whether monolithic zirconia crowns represent a more successful alternative is unclear. PURPOSE: The purpose of this systematic review and meta-analysis was to compare the clinical outcomes of posterior monolithic zirconia and metal-ceramic implant-supported single crowns. MATERIAL AND METHODS: A search was conducted in MEDLINE, Scopus, Embase, Web of Science, and CENTRAL databases for randomized controlled trials up to April 2023 with a follow-up time of at least 1 year. Restoration and implant survival and failure rates, marginal bone loss (MBL), bleeding on probing (BOP), and technical complications were analyzed by 2 reviewers. Statistical analyses were conducted using the R-statistics software program. The risk of bias was assessed by the Cochrane Risk of Bias Tool 2 (RoB 2), and the certainty of evidence by the Grading of Recommendations, Assessment, Development and Evaluation (GRADE) approach. RESULTS: A total of 11 out of 2030 records were identified by title and abstract, and 4 records were included after full-text analysis. The statistical analysis revealed no significant difference in MBL (MD -0.11, 95% CI: [-0.25; 0.03]), BOP (OR 0.66, 95% CI: [0.25; 1.77]), or implant failure (OR 1.30, 95% CI: [0.24; 7.08]). Monolithic zirconia presented significantly less chipping over 1 year (OR 0.17, 95% CI: [0.03; 0.99]). The chipping rate was 0% for monolithic zirconia and 7.61% for metal-ceramic. Based on a narrative review, the restoration survival rate was 97.5% in the monolithic zirconia group and 99.1% in the metal-ceramic group. CONCLUSIONS: Monolithic zirconia showed favorable short-term survival rates and had significantly less chipping over 1 year. Regarding MBL, BOP, and failure rates, both restoration types presented similar results at the 1-year follow-up.

3.
Eur J Orthod ; 45(2): 175-185, 2023 03 31.
Artículo en Inglés | MEDLINE | ID: mdl-36222731

RESUMEN

BACKGROUND: Bracket failure increases the treatment time of orthodontic therapy and burdens patients with unnecessary costs, increased chair time, and possible new appointments. OBJECTIVE: To compare the bond failures of different orthodontic materials based on the results of available clinical studies. SEARCH METHODS: A systematic search of clinical trials was performed in the Cochrane, Embase, and Pubmed databases with no limitations. The list of investigated techniques contained conventional acid-etch primer (CM-AEP), self-etch primer (SEP), self-cure resin (SCR), and simple or resin-modified glass ionomer (RM-GIC) materials and procedures. SELECTION CRITERIA: Clinical studies reporting the failure rate of bonded brackets after using direct adhesive techniques on buccal sites of healthy teeth were included. DATA COLLECTION AND ANALYSIS: Bracket failure rates from eligible studies were extracted by two authors independently. Risk ratios (RRs) were pooled using the random-effects model with DerSimonian-Laird estimation. RESULTS: Thirty-four publications, involving 1221 patients, were included. Our meta-analysis revealed no significant difference in the risk of bracket failures between SEP and CM-AEP. After 6, 12, and 18 months of bonding, the values of RR were 1.04 [95% confidence interval (CI), 0.67-1.61], 1.37 (95% CI, 0.98-1.92), and 0.93 (95% CI, 0.72-1.20), respectively. At 18 months, bracket failure was 4.9 and 5.2% for SEP and CM-AEP, respectively. Heterogeneity was good or moderate (I2 < 42.2%). The results of RM-GIC at 12 months indicated a 57% lower risk of bracket failure using SCR as compared with RM-GIC (RR: 0.38; 95% CI, 0.24-0.61). At 18 months, bracket failures for SCR and RM-GIC were 15.8 and 36.6%, respectively (RR: 0.44; 95% CI, 0.37-0.52, I2 = 78.9%), demonstrating three to six times higher failure rate than in the case of etching primer applications. LIMITATIONS: A major limitation of the present work is that the included clinical trials, with no exceptions, showed variable levels of risk of bias. Another possible problem affecting the outcome is the difference between the clustering effects of the split mouth and the parallel group bracket allocation methods. CONCLUSIONS AND IMPLICATIONS: The results revealed no significant difference between SEP and CM-AEP up to 18 months after application. RM-GIC had much worse failure rates than acid-etching methods; additionally, the superiority of SCR over RM-GIC was evident, indicating strong clinical relevance. REGISTRATION: Prospero with CRD42020163362.


Asunto(s)
Recubrimiento Dental Adhesivo , Soportes Ortodóncicos , Humanos , Factores de Tiempo , Recubrimiento Dental Adhesivo/métodos , Cementos de Resina/química
4.
J Evid Based Dent Pract ; 23(3): 101862, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37689445

RESUMEN

BACKGROUND: The gold standard method for diagnosing oral halitosis is the subjective organoleptic measurement. Device-supported methods are also widespread worldwide. The challenges and safety concerns around performing organoleptic measurements during pandemics and the diversity of measuring device alternatives raised our clinical question: which halitometer is the most suitable for diagnosing halitosis? METHODS: This systematic review was registered in PROSPERO (ID CRD42022320024). The search was performed on March 23, 2022 in the following electronic databases: MEDLINE, Embase, Scopus, Web of Science, and CENTRAL. Adult populations with or without halitosis were included, and patients with systemic diseases were excluded. Organoleptic (subjective) measurement and the device-supported (objective) methods were compared; the primary outcome was the correlation coefficient, and the secondary was the specificity and sensitivity of the devices. QUADAS-2 and QUADAS-C were used to evaluate the risk of bias in the studies. Random-effects meta analyses were performed on the outcomes, and the secondary outcomes were plotted on a common ROC plot. RESULTS: A total of 1231 records were found in the 5 databases. After the selection process, 76 articles were eligible for the systematic review, and 14,635 patients were involved in the qualitative analysis. The pooled Spearman's correlation coefficient (c.c.) for sulfide monitors was 0.65; 95% CIs: [0.53-0.74]; I2 = 95%, P < .01. The pooled Spearman's c.c. for portable gas chromatographs was 0.69; 95% CIs: [0.63-0.74]; I2 = 12%, P < .01. The pooled Spearman's c.c. for gas chromatographs was 0.76; 95% CIs: [0.67-0.83]; I2 = 0%, P < .01. DISCUSSION: None of the most commonly used halitometers proved to be significantly superior to the others. Halimeter and OralChroma measurements did not correlate well with the organoleptic level of oral halitosis in adults. Therefore, better halitometers need to be developed as an alternative to organoleptic measurements.


Asunto(s)
Halitosis , Adulto , Humanos , Halitosis/diagnóstico , Sensación , Sulfuros
5.
Paediatr Perinat Epidemiol ; 36(2): 276-287, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-35041216

RESUMEN

BACKGROUND: Maternal overnutrition during pregnancy predisposes the offspring to cardiometabolic diseases. OBJECTIVES: This systematic review and meta-analysis aimed to investigate the association between maternal overnutrition and offspring's blood pressure (BP) and the effect of offspring's obesity on this association. DATA SOURCES: PubMed, EMBASE, Clinicaltrials.gov, CENTRAL. STUDY SELECTION AND DATA EXTRACTION: Human studies published in English before October 2021 were identified that presented quantitative estimates of association between maternal overnutrition just before or during pregnancy and the offspring's BP. SYNTHESIS: Random-effect model with the DerSimonian and Laird weighting method was used to analyse regression coefficients or mean differences. RESULTS: After selection, 17 observational studies (140,517 mother-offspring pairs) were included. Prepregnancy body mass index (ppBMI) showed positive correlation with BP in offspring (regression coefficient for systolic: 0.38 mmHg per kg/m2 , 95% confidence interval (CI) 0.17, 0.58; diastolic: 0.10 mmHg per kg/m2 , 95% CI 0.05, 0.14). These indicate 1.9 mmHg increase in systolic and 0.5 mmHg increase in diastolic BP of offspring with every 5 kg/m2 gain in maternal ppBMI. Results on coefficients adjusted for offspring's BMI also showed association (systolic: 0.08 mmHg per kg/m2 , 95% CI 0.04, 0.11; diastolic: 0.03 mmHg per kg/m2 , 95% CI 0.01, 0.04). Independent from ppBMI, gestational weight gain (GWG) showed positive correlation with systolic BP (systolic BP: 0.05 mmHg per kg, 95% CI 0.01, 0.09), but not after adjustment for offspring's BMI. Mean systolic BP was higher in children of mothers with excessive GWG than in those of mothers with optimal GWG (difference: 0.65 mmHg, 95% CI 0.25, 1.05). CONCLUSIONS: Independent from offspring's BMI, higher prepregnancy BMI may increase the risk for hypertension in offspring. The positive association between GWG and offspring's systolic BP is indirect via offspring's obesity. Reduction in maternal obesity and treatment of obesity in children of obese mothers are needed to prevent hypertension.


Asunto(s)
Ganancia de Peso Gestacional , Hipertensión , Obesidad Infantil , Presión Sanguínea/fisiología , Índice de Masa Corporal , Niño , Femenino , Humanos , Hipertensión/epidemiología , Hipertensión/etiología , Obesidad Infantil/epidemiología , Obesidad Infantil/etiología , Embarazo
6.
BMC Public Health ; 20(1): 691, 2020 May 28.
Artículo en Inglés | MEDLINE | ID: mdl-32460747

RESUMEN

BACKGROUND: The quadrivalent human papillomavirus (HPV) vaccine has been assumed to give protection against genital warts (GW) as well as cervical cancer. Our main question was whether HPV vaccine has any effects on the prevention of GW reported in randomised controlled clinical trials (RCTs) and time-trend analyses. METHODS: This meta-analysis was performed according to the PRISMA guidelines using the PICO format. We searched in three electronic databases (PubMed, Embase, Cochrane Trials), and assessed heterogeneity using the Q-test and I-squared statistics, meta-regression was also performed. Odds ratios (OR) and their confidence intervals (CI) were calculated. The sensitivity was tested by leave-one-out method. We evaluated the presence of publication bias using the funnel plot graph and the Copas selection model. The strength of evidence was assessed using the GRADE approach. RESULTS: Eight RCTs (per-protocol populations) and eight time-trend ecological studies were included in this meta-analysis. A significant reduction (pooled OR = 0.03, 95% CI: 0.01-0.09; I-squared = 53.6%) of GW in young women was recorded in RCTs, and in time-trend analyses both in young women (pooled OR = 0.36, CI 95% = 0.26-0.51; I-squared = 98.2%), and in young men (pooled OR = 0.69, 95% CI = 0.61-0.78; I-squared = 92.7%). In subgroup analysis, a significant reduction of the number of GW events was observed especially in women under 21 years (pooled OR = 0.33, 95% CI = 0.17-0.63). Leave-one-out analysis showed that similar results could be obtained after excluding one study, meta-regression did not show significant difference. CONCLUSIONS: Prophylactic, quadrivalent HPV vaccination can prevent GW in healthy women and men, therefore, it should be included in routine immunization programme.


Asunto(s)
Condiloma Acuminado/prevención & control , Programas de Inmunización/estadística & datos numéricos , Infecciones por Papillomavirus/prevención & control , Vacunas contra Papillomavirus/administración & dosificación , Neoplasias del Cuello Uterino/prevención & control , Vacunación/estadística & datos numéricos , Adolescente , Adulto , Niño , Condiloma Acuminado/epidemiología , Femenino , Humanos , Masculino , Infecciones por Papillomavirus/epidemiología , Vacunas contra Papillomavirus/uso terapéutico , Ensayos Clínicos Controlados Aleatorios como Asunto , Neoplasias del Cuello Uterino/epidemiología , Adulto Joven
7.
J Prosthodont Res ; 68(1): 1-11, 2024 Jan 16.
Artículo en Inglés | MEDLINE | ID: mdl-37286516

RESUMEN

Purpose To assess the accuracy of scanning technologies for constructing facial prostheses on human faces.Study selection Our systematic search was performed on five databases. Studies reporting on human volunteers (P) whose faces were scanned with a scanning technology were eligible. The anthropometrical interlandmark distances (ILDs) were used as indicators of accuracy; the ILDs are measured on the virtual models (I) and directly on the faces (C). The virtual models deviated from their true values (O). Studies reporting the measurements on patients with or without facial deformities were included, but cadavers or inanimate objects were reasons for exclusion. We performed a mean difference (MD) / standardized MD analysis with a random effect model. The difficulties regarding the scanning procedure mentioned in the articles were also assessed.Results We found 3723 records after duplicate removal. Twenty five articles were eligible for the qualitative review, and ten articles were included in the quantitative synthesis. Eight different ILDs were compared in MD analyses. The differences were between -0.54-0.43 mm. We also performed a regional three-dimensional analysis to compare scanning technologies in each major region. No significant differences were found in any of the regions and axes. The most mentioned difficulties were artifacts due to motion or blinking.Conclusions The results suggest no systematic skew in linear dimensions neither between direct caliper measurements nor between measurements on the scanned models, scanning technologies, or facial regions.


Asunto(s)
Cara , Imagenología Tridimensional , Humanos
8.
J Clin Med ; 13(6)2024 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-38542042

RESUMEN

Background: Women are typically diagnosed with estrogen receptor-positive breast cancer around the postmenopausal period when declining estrogen levels initiate changes in lipid profiles. Aromatase inhibitors (AI) are used to prevent the progression of cancer; however, a further reduction in estrogen levels may have detrimental effects on lipid levels, which was our working hypothesis. Methods: Our meta-analysis was conducted on the lipid profiles of postmenopausal breast cancer patients at baseline and at different treatment time points. Results: We identified 15 studies, including 1708 patients. Studies using anastrozole (ANA), exemestane (EXE), letrozole (LET), and tamoxifen (TMX) were involved. Subgroup analyses revealed that 3- and 12-month administrations of LET and EXE lead to negative changes in lipid profiles that tend to alter the lipid profile undesirably, unlike ANA and TMX. Conclusions: Our results suggest that, despite statistically significant results, EXE and LET may not be sufficient to cause severe dyslipidemia in patients without cardiovascular comorbidities according to the AHA/ACC Guideline on the Management of Blood Cholesterol. However, the results may raise the question of monitoring the effects of AIs in patients, especially those with pre-existing cardiovascular risk factors such as dyslipidemia.

9.
J Dent ; 137: 104636, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37516338

RESUMEN

OBJECTIVES: This network meta-analysis (NMA) aimed to compare the complete-arch scanning accuracy of different intraoral scanners (IOSs) to that of reference standard tessellation language (STL) files. DATA: Studies comparing the trueness and precision of IOS STL files with those of reference STL scans for different arch types (dentate, edentulous, completely edentulous with implants, and partially edentulous with implants) were included in this study. SOURCES: An electronic search of five databases restricted to the English Language was conducted in October 2021. STUDY SELECTION: A total of 3,815 studies were identified, of which 114 were eligible for inclusion. After study selection and data extraction, pair-wise comparison and NMA were performed to define the accuracy of scanning for four arch subgroups using four outcomes (trueness and precision expressed as mean absolute deviation and root mean square values). Cochrane guidelines and the QUADAS-2 tool were used to assess the risk of bias. GRADE was used for certainty assessment. RESULTS: Fifty-three articles were included in this NMA. Altogether, 26 IOSs were compared directly and indirectly in 10 network systems. The accuracy of IOSs scans were not significantly different from the reference scans for dentate arches (three IOSs), edentulous arches (three IOSs), and completely edentulous arches with implants (one IOS). The accuracy of the IOSs was significantly different from the reference scans for partially edentulous arches with implants. Significant accuracy differences were found between the IOSs, regardless of clinical scenarios. CONCLUSIONS: The accuracy of complete-arch scanning by IOSs differs based on clinical scenarios. CLINICAL SIGNIFICANCE: Different IOSs should be used according to the complete arch type.


Asunto(s)
Imagenología Tridimensional , Boca Edéntula , Humanos , Metaanálisis en Red , Diseño Asistido por Computadora , Técnica de Impresión Dental , Modelos Dentales , Boca Edéntula/diagnóstico por imagen , Arco Dental/diagnóstico por imagen
10.
PLoS One ; 18(1): e0280377, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36634129

RESUMEN

OBJECTIVES: We aimed to conduct a systematic review on published data in order to investigate the efficacy of mouthwash products containing chlorine dioxide in halitosis. STUDY DESIGN: Systematic review and meta-analysis. METHODS: Our search was conducted on 14th October 2021. We searched the following electronic databases: MEDLINE, Embase, Scopus, Web of Science, and CENTRAL. We analysed data on adults with halitosis, included only randomised controlled trials and excluded in vitro and animal studies. The interventional groups used chlorine dioxide, and the comparator groups used a placebo or other mouthwash. Our primary outcomes were changes in organoleptic test scores (OLS) and Volatile Sulfur Compound (VSC) levels from baseline to the last available follow-up. RESULTS: We found 325 articles in databases. After the selection process, ten articles were eligible for qualitative synthesis, and 7 RCTs with 234 patients were involved in the meta-analysis. Our findings showed a significant improvement in the parameters of the chlorine dioxide group compared to the placebo group in OLS one-day data (mean difference (MD): -0.82; 95% confidence intervals (95% CIs): [-1.04 --0.6]; heterogeneity: I2 = 0%, p = 0.67); and one-week OLS data (MD: -0.24; 95% CIs: [-0.41 --0.07]; I2 = 0%, p = 0.52); and also changes in H2S one-day data (standardised mean difference (SMD): -1.81; 95% CIs: [-2.52 --1.10]); I2 = 73.4%, p = 0.02). CONCLUSION: Our data indicate that chlorine dioxide mouthwash may be a good supportive therapy in oral halitosis without known side effects.


Asunto(s)
Compuestos de Cloro , Halitosis , Humanos , Compuestos de Cloro/uso terapéutico , Halitosis/tratamiento farmacológico , Antisépticos Bucales/uso terapéutico , Óxidos/uso terapéutico , Ensayos Clínicos Controlados Aleatorios como Asunto
11.
Front Surg ; 8: 681028, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34422892

RESUMEN

Introduction: The lips and the mouth play an indispensable role in vocalization, mastication and face aesthetics. Various noxious factors may alter and destruct the original structure, and appearance of the lips and the anatomical area surrounding the mouth. The application of hyaluronic acid (HA) may serve as a safe method for lip regeneration. Although a number of studies exist for HA effectiveness and safety, its beneficial effect is not well-established. Aim: The present meta-analysis and systematic review was performed to investigate the effectiveness of HA on lip augmentation. We also investigated the types and nature of adverse effects (AEs) of HA application. Methods: We reported our meta-analysis in accordance with the PRISMA Statement. PROSPERO protocol registration: CRD42018102899. We performed the systematic literature search in CENTRAL, Embase, and MEDLINE. Randomized controlled trials, cohort studies, case series and case reports were included. The untransformed proportion (random-effects, DerSimonian-Laird method) of responder rate to HA injection was calculated. For treatment related AEs descriptive statistics were used. Results: The systematic literature search yielded 32 eligible records for descriptive statistics and 10 records for quantitative synthesis. The results indicated that the overall estimate of responders (percentage of subjects with increased lip fullness by one point or higher) was 91% (ES = 0.91, 95% CI:0.85-0.96) 2 months after injection. The rate of responders was 74% (ES = 0.74, 95% CI:0.66-0.82) and 46% (ES = 0.46, 95% CI:0.28-0.65) after 6 and 12 months, respectively. We included 1,496 participants for estimating the event rates of AEs. The most frequent treatment-related AEs were tenderness (88.8%), injection site swelling (74.3%) and bruising (39.5%). Rare AEs included foreign body granulomas (0.6%), herpes labialis (0.6%) and angioedema (0.3%). Conclusion: Our meta-analysis revealed that lip augmentation with injectable HA is an efficient method for increasing lip fullness for at least up to 6 months after augmentation. Moreover, we found that most AEs of HA treatment were mild or moderate, but a small number of serious adverse effects were also found. In conclusion, further well-designed RCTs are still needed to make the presently available evidence stronger.

12.
Front Pharmacol ; 12: 682656, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34447307

RESUMEN

Introduction: At the initial part of the gastrointestinal tract, multiple tissues serve the normal function of food delivery. Periodontal structures are integral elements of these. When they deteriorate, it is extremely challenging to regenerate and reconstruct them. The conventional intervention for periodontal disease is scaling and root planning with the aim of reducing pathogenic bacteria. However, periodontal pathogens can rapidly recolonize treated areas. Probiotics have been proposed as novel tools for managing oral health by suppressing pathogenic bacteria through their anti-inflammatory effect, but the available data are controversial. Aim: Therefore, we performed a meta-analysis to study the effect of probiotics on periodontal pathogenic bacteria. Methods: The study was registered in PROSPERO under registration number CRD42018094903. A comprehensive literature search from four electronic databases (PubMed, Cochrane CENTRAL, Embase, and Web of Science) yielded nine eligible records for statistical analysis. Studies measuring bacterial counts in saliva and supra- and subgingival plaque were included. Bacterial counts were analyzed using standard mean difference (SMD) and by a random effects model with the DerSimonian-Laird estimation. Results: The results showed a significant decrease in the overall count of Aggregatibacter actinomycetemcomitans in the probiotic-treated group compared to the control at 4 weeks (SMD: -0.28; 95% CI: -0.56--0.01; p = 0.045) but not later. Analyzing the bacterial counts in subgroups, namely, in saliva and supra- and subgingival plaque, separately, yielded no significant difference. Probiotics had no significant effect on the overall count of Porphyromonas gingivalis at 4 weeks (SMD: -0.02; 95% CI: -0.35-0.31; p = 0.914) or later. Subgroup analysis also revealed no significant difference between treatment and control groups nor did probiotics significantly decrease the overall and subgroup bacterial counts of Prevotella intermedia, Tannerella forsythia, and Fusobacterium nucleatum. Conclusion: Our data support the beneficial effect of probiotics in reducing A. actinomycetemcomitans counts, but not of other key periodontal pathogenic bacteria in periodontal disease patients. However, due to the complex mechanism associated with periodontal disease and the limitations of the available studies, there is a further need for well-designed randomized clinical trials to assess the efficacy of probiotics.

13.
Front Med (Lausanne) ; 7: 465, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32903849

RESUMEN

Background: COVID-19 is a serious and potentially deadly disease. Early diagnosis of infected individuals will play an important role in stopping its further escalation. The present gold standard for sampling is the nasopharyngeal swab method. However, several recent papers suggested that saliva-based testing is a promising alternative that could simplify and accelerate COVID-19 diagnosis. Objectives: Our aim was to conduct a meta-analysis on the reliability and consistency of SARS-CoV-2 viral RNA detection in saliva specimens. Methods: We have reported our meta-analysis according to the Cochrane Handbook. We searched the Cochrane Library, Embase, Pubmed, Scopus, Web of Science and clinical trial registries for eligible studies published between 1 January and 25 April 2020. The number of positive tests and the total number of tests conducted were collected as raw data. The proportion of positive tests in the pooled data were calculated by score confidence-interval estimation with the Freeman-Tukey transformation. Heterogeneity was assessed using the I 2 measure and the χ2-test. Results: The systematic search revealed 96 records after removal of duplicates. Twenty-six records were included for qualitative analysis and 5 records for quantitative synthesis. We found 91% (CI 80-99%) sensitivity for saliva tests and 98% (CI 89-100%) sensitivity for nasopharyngeal swab (NPS) tests in previously confirmed COVID-19 patients, with moderate heterogeneity among the studies. Additionally, we identified 18 registered, ongoing clinical trials of saliva-based tests for detection of the virus. Conclusion: Saliva tests offer a promising alternative to NPS for COVID-19 diagnosis. However, further diagnostic accuracy studies are needed to improve their specificity and sensitivity.

14.
J Endod ; 46(8): 1032-1041.e7, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32413440

RESUMEN

INTRODUCTION: We aimed to compare the antimicrobial efficacy of chlorhexidine (CHX) and sodium hypochlorite (NaOCl), 2 irrigants routinely used in root canal therapy of permanent teeth. METHODS: Electronic databases, including PubMed, EMBASE, Web of Science, and Cochrane Library, were searched for randomized controlled trials published until March 2020. The meta-analysis of relative risk (RR) and standardized mean difference (SMD) was performed using a random effects model with a 95% confidence interval (CI). Subgroup analysis was performed for culture and molecular methods of bacterial detection. RESULTS: The literature search yielded 2110 records without duplicates. Eight studies were eligible for a systematic review. No significant differences in the incidence of samples with positive bacterial growth after irrigation (RR = 1.003; 95% CI, 0.729-1.380; P = .987) and mean bacterial number changes (SMD = 0.311; 95% CI, -0.368 to 0.991; P = .369) were observed between CHX and NaOCl in the culture and molecular subgroups. Heterogeneity in RR (I2 = 0%, P = .673) was low among studies, whereas considerable heterogeneity was observed in the analysis of SMD (I2 = 76.336%, P = .005). CONCLUSIONS: Our findings suggest that both CHX and NaOCl can reduce bacterial infections after irrigation without any significant difference in antimicrobial efficacy between them. Although CHX and NaOCl showed similar efficacy, their molecular mechanisms were different. Therefore, they can be used as the main antibacterial root canal irrigants. However, our results were limited by inconsistencies among retrieved articles and a lack of clinically relevant outcomes. Further well-designed clinical studies are warranted to supplement our results.


Asunto(s)
Antibacterianos/uso terapéutico , Clorhexidina/uso terapéutico , Irrigantes del Conducto Radicular/uso terapéutico , Hipoclorito de Sodio/uso terapéutico , Cavidad Pulpar , Enterococcus faecalis , Ensayos Clínicos Controlados Aleatorios como Asunto , Tratamiento del Conducto Radicular
15.
PLoS One ; 14(5): e0216428, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31050690

RESUMEN

INTRODUCTION: Sandblasting is one of the oldest implant surface modifications to enhance osseointegration. Regarding its superiority over machined surface controversies still exist. Our objective was to compare implant failures (IF) and marginal bone level (MBL) changes between sandblasted and machined dental implants by a meta-analysis utilizing the available data. The PROSPERO registration number of the meta-analysis is CRD42018084190. METHODS: The systematic search was performed in Cochrane, Embase and Pubmed. Inclusion criteria included participants with neither systemic diseases, nor excessive alcohol consumption, nor heavy smoking. We calculated pooled Risk Ratio (RRs) with confidence intervals of 95% (CIs) for dichotomous outcomes (implant failure) and weighted mean difference (WMD) CIs of 95% for continuous outcomes (marginal bone level change). We applied the random effect model with DerSimonian-Laird estimation. I2 and chi2 tests were used to quantify statistical heterogeneity and gain probability-values, respectively. RESULTS: Literature search revealed 130 records without duplicates. Out of these, seven studies met the inclusion criteria and all were included in data synthesis, involving 362 sand-blasted and 360 machined implants. The results indicate that there is an 80% (RR = 0.2 95% CI:0.06-0.67; I2 = 0.0% p = 0.986) lower among sandblasted compared to machined implants after one year of use and 74% (RR = 0.26 95% CI:0.09-0.74; I2 = 0.0% p = 0.968) five years of use, respectively. In contrast, there is no significant difference in MBL (WMD:-0.10mm, 95% CI:-0.20, 0.01; p>0.05; I2 = 0.0%, p = 0.560 and WMD:-0.01mm, 95% CI:-0.12, 0.09; p>0.05; I2 = 26.2%, p = 0.258) between the two implant surfaces after one and five years of use. CONCLUSIONS: This meta-analysis reveals that sandblasting is superior over machined surface in implant failure but not in marginal bone level in healthy subjects. It also points out the need for further randomized clinical trials with large sample size for objective determination of the clinical benefits of certain implant surface modifications.


Asunto(s)
Implantación Dental Endoósea/efectos adversos , Implantes Dentales/efectos adversos , Fracaso de la Restauración Dental , Oseointegración , Enfermedades Óseas Metabólicas/etiología , Enfermedades Óseas Metabólicas/metabolismo , Enfermedades Óseas Metabólicas/patología , Humanos
16.
Phytomedicine ; 63: 152984, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31255877

RESUMEN

BACKGROUND: A fixed combination of hawthorn and camphor (Korodin Herz-Kreislauf-Tropfen®) has been used in the therapy of hypotension for decades. Although its efficacy was evaluated in clinical trials, these studies have not been critically assessed in meta-analyses. PURPOSE: To systematically evaluate the efficacy of a fix combination of camphor and hawthorn extract (Korodin®) on blood pressure and cognition compared to placebo, in a meta-analysis based on randomized controlled trials (RCTs). STUDY DESIGN: The meta-analysis was carried out following the PRISMA guidelines, using the PICO format, and it was registered in the PROSPERO register. METHODS: The Cochrane Central Register of Controlled Trials, PubMed, Embase, and Web of Science databases were searched for relevant studies. Placebo-controlled clinical studies involving adult patients receiving a fix combination of hawthorn extract and camphor were included. No language or publication year restrictions were applied. RESULTS: Four randomized trials including a total of 221 patients were pooled for statistical analysis. According to the present meta-analysis, the fixed combination of hawthorn and camphor significantly increases systolic and diastolic blood pressure compared to placebo (p-values: 0.017 and 0.049, respectively) and had a beneficial, but not statistically significant effect on the cognitive performance in the connect-the-numbers test (p-value: 0.071). CONCLUSION: Korodin® is an effective and presumably safe complementary therapy for the treatment of hypotension. Its blood pressure increasing effect is confirmed; however, the evidence supporting its use is very limited. The optimum dose and duration of treatment is still unclear. The comprehensive evaluation of efficacy and safety is required in further, high-quality clinical studies, involving larger patient populations and comparable endpoints.


Asunto(s)
Presión Sanguínea/efectos de los fármacos , Alcanfor/farmacología , Crataegus/química , Extractos Vegetales/farmacología , Adulto , Cognición/efectos de los fármacos , Humanos , Hipotensión/tratamiento farmacológico , Ensayos Clínicos Controlados Aleatorios como Asunto , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA