Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 56
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Eur Heart J ; 45(10): 823-833, 2024 Mar 07.
Artículo en Inglés | MEDLINE | ID: mdl-38289867

RESUMEN

BACKGROUND AND AIMS: An electrical storm (ES) is a clinical emergency with a paucity of established treatment options. Despite initial encouraging reports about the safety and effectiveness of percutaneous stellate ganglion block (PSGB), many questions remained unsettled and evidence from a prospective multicentre study was still lacking. For these purposes, the STAR study was designed. METHODS: This is a multicentre observational study enrolling patients suffering from an ES refractory to standard treatment from 1 July 2017 to 30 June 2023. The primary outcome was the reduction of treated arrhythmic events by at least 50% comparing the 12 h following PSGB with the 12 h before the procedure. STAR operators were specifically trained to both the anterior anatomical and the lateral ultrasound-guided approach. RESULTS: A total of 131 patients from 19 centres were enrolled and underwent 184 PSGBs. Patients were mainly male (83.2%) with a median age of 68 (63.8-69.2) years and a depressed left ventricular ejection fraction (25.0 ± 12.3%). The primary outcome was reached in 92% of patients, and the median reduction of arrhythmic episodes between 12 h before and after PSGB was 100% (interquartile range -100% to -92.3%). Arrhythmic episodes requiring treatment were significantly reduced comparing 12 h before the first PSGB with 12 h after the last procedure [six (3-15.8) vs. 0 (0-1), P < .0001] and comparing 1 h before with 1 h after each procedure [2 (0-6) vs. 0 (0-0), P < .001]. One major complication occurred (0.5%). CONCLUSIONS: The findings of this large, prospective, multicentre study provide evidence in favour of the effectiveness and safety of PSGB for the treatment of refractory ES.


Asunto(s)
Taquicardia Ventricular , Anciano , Femenino , Humanos , Masculino , Estudios Prospectivos , Ganglio Estrellado , Volumen Sistólico , Taquicardia Ventricular/terapia , Taquicardia Ventricular/etiología , Resultado del Tratamiento , Fibrilación Ventricular/etiología , Función Ventricular Izquierda , Persona de Mediana Edad
2.
J Cardiovasc Electrophysiol ; 34(3): 728-737, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36477909

RESUMEN

INTRODUCTION: Lead dwell time >10 years is a recognized predictor for transvenous lead extraction (TLE) failure and complications. Data on the efficacy and safety of TLE using the bidirectional rotational mechanical sheaths in patients with very old leads are lacking. In this multicenter study, we reported the outcomes of transvenous rotational mechanical lead extraction in patients with leads implanted for ≥10 years. METHODS: A total of 441 leads (median: 159 months [135-197]; range: 120-487) in 189 consecutive patients were removed with the Evolution RL sheaths (Cook Medical, Bloomingtom, IN, USA) and mechanical ancillary tools supporting the procedures. RESULTS: The main indication for TLE was infection in 74% of cases. Complete procedural success rate, clinical success rate, per lead were 94.8% and 98.2%, respectively. Failure of lead extraction was seen in 1.8% of leads. The additional use of a snare via the femoral approach was required in 9% of patients. Lead dwell time was the only predictor of incomplete led removal (odds ratio: 1.009; 95% confidence interval [CI]: 1.003-1.014; p = .002). Four major complication (2%) were encountered. During a mean time follow-up of 31 ± 27 months, 21 patients (11%) died. No procedure-related mortality occurred. Predictors of mortality included severe left ventricular systolic dysfunction (hazard ratio [HR]: 8.06; 95% CI: 2.99-21.73; p = .001), TLE for infection (HR: 8.0; 95% CI: 1.04-62.5; p = .045), diabetes (HR: 3.7; 95% CI: 1.48-9.5; p = .005), and previous systemic infection (HR: 3.1; 95% CI: 1.17-8.24; p = .022). Incomplete lead removal or failure lead extraction did not impact on survival during follow-up. CONCLUSION: Our findings demonstrated that the use of bidirectional rotational TLE mechanical sheaths combined with different mechanical tools and femoral approach allows reasonable success and safety in patients with very old leads at experienced specialized centers.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Humanos , Remoción de Dispositivos/métodos , Electrodos Implantados , Estudios Retrospectivos , Resultado del Tratamiento
3.
Catheter Cardiovasc Interv ; 101(6): 1144-1153, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36924020

RESUMEN

AIMS: To compare outcomes of patients who underwent left atrial appendage occlusion (LAAO) for nonvalvular atrial fibrillation (NVAF) and contraindication to anticoagulants due to history of either gastrointestinal (GI) or intracranial (IC) bleeding. METHODS: Patients with NVAF that underwent LAAO for GI or IC bleeding from seven centers were included in this observational study. Baseline characteristics, procedural features, and follow-up data were collected, and compared between the two groups. The primary outcomes were incidence of ischemic and hemorrhagic events at 12-month. RESULTS: Six hundred twenty-eight patients were included, 57% with previous GI-bleeding, and 43% with previous IC-bleeding. Median CHA 2 DS 2-VASc score was 4 (interquartile range [IQRs]: 3-5) for both GI-bleeding and IC-bleeding patients, while GI-bleeding patients had a higher HAS-BLED score (4 [IQRs: 3-4] vs. 3 [IQRs]: 2-3]; p = 0.001). At 12-month follow-up, relative risk reduction for stroke was similar between the two groups. The GI-bleeding group had more hemorrhagic events compared to IC-bleeding group (any bleeding 8.4% vs. 3.2%; p = 0.012; major bleeding BARC 3-5: 4.3% vs. 1.8; p = 0.010). At multivariate analysis history of GI bleeding was an independent predictor of hemorrhagic events (adjusted HR: 2.39, 95% confidence interval: 1.02-5.63; p = 0.047). CONCLUSIONS: Outcomes after LAAO may be affected by the different indications for the procedure. In our study, GI-bleeding and IC-bleeding as indication to LAAO differ in their baseline characteristics. LAAO confirms its efficacy in ischemic risk reduction in both groups, while GI bleeding seems to be an independent predictor of bleeding recurrence at 12 months behind the antithrombotic regimen.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Humanos , Apéndice Atrial/diagnóstico por imagen , Resultado del Tratamiento , Hemorragia Gastrointestinal/diagnóstico , Hemorragia Gastrointestinal/etiología , Hemorragia Gastrointestinal/prevención & control , Hemorragias Intracraneales/etiología , Sistema de Registros , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/terapia , Lógica
4.
Pacing Clin Electrophysiol ; 45(6): 752-760, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35403246

RESUMEN

BACKGROUND: Little is known regarding the characterization of electrical substrate in both atria in patients with atrial fibrillation (AF). METHODS: Eight consecutive patients undergoing AF ablation (five paroxysmal, three persistent) underwent electrical substrate characterization during sinus rhythm. Mapping of the left (LA) and right atrium (RA) was performed with the use of the HD Grid catheter (Abbott). Bipolar voltage maps were analyzed to search for low voltage areas (LVA), the following electrophysiological phenomena were assessed: (1) slow conduction corridors, and (2) lines of block. EGMs were characterized to search for fractionation. Electrical characteristics were compared between atria and between paroxysmal versus persistent AF patients. RESULTS: In the RA, LVAs were present in 60% of patients with paroxysmal AF and 100% of patients with persistent AF. In the LA, LVAs were present in 40% of patients with paroxysmal AF and 66% of patients with persistent AF. The areas of LVA in the RA and LA were 4.8±7.3 cm2 and 7.8±13.6 cm2 in patients with paroxysmal AF versus 11.7±3.0 cm2 and 2.1±1.8 cm2 in patients with persistent AF. In the RA, slow conduction corridors were present in 40.0% (paroxysmal AF) versus 66.7% (persistent AF) whereas in the LA, slow conduction corridors occurred in 20.0% versus 33.3% respectively (p = ns). EGM analysis showed more fractionation in persistent AF patients than paroxysmal (RA: persistent AF 10.8 vs. paroxysmal AF 4.7%, p = .036, LA: 10.3 vs. 4.1%, p = .108). CONCLUSION: Bi-atrial involvement is present in patients with paroxysmal and persistent AF. This is expressed by low voltage areas and slow conduction corridors whose extension progresses as the arrhythmia becomes persistent. This electrophysiological substrate demonstrates the important interplay with the pulmonary vein triggers to constitute the substrate for persistent arrhythmia.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/cirugía , Técnicas Electrofisiológicas Cardíacas , Atrios Cardíacos , Humanos , Venas Pulmonares/cirugía
5.
Pacing Clin Electrophysiol ; 45(1): 23-34, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34841552

RESUMEN

BACKGROUND: Left atrial appendage (LAA) thrombosis increases the risk of stroke and its management has to be assessed. The aim of the present study is to evaluate short and long-term safety and efficacy of a standardized approach of percutaneous LAA closure (LAAC) routinely using a cerebral protection device (CPD) in patients with LAA thrombosis or sludge (LAAT). METHODS: We prospectively enrolled 14 consecutive patients with atrial fibrillation complicated by LAAT presenting in a high-volume tertiary center. In seven patients (50%) LAAT was found after anticoagulant withdrawal for severe bleedings and in the remaining half LAAT was found despite appropriate anticoagulant therapy. All patients were treated with a standardized interventional approach of LAAC routinely using a CPD and guided by transoesophageal echocardiography. RESULTS: Mean age was 68 ± 14 years and nine patients (64%) were male. Mean CHA2 DS2 -VASc and HAS-BLED scores were 3.3 ± 1.6 and 2.3 ± 1.1, respectively. Six patients (42.8%) presented organized thrombi while eight LAA sludge (57.1%). In 13 patients (92.8%) CPD was positioned through a right radial arterial access. Procedural success was achieved in all patients. In one patient we assisted to embolization of the thrombus during deployment of the device in the absence of neurological consequences. During a mean follow up of 426 ± 307 days, one patient died for non-cardiac cause while no embolic event or major bleeding were reported. CONCLUSION: In an unselected cohort, LAAC with the systematic use of CPD was a feasible, safe and effective therapeutic option for LAAT both acutely and after long-term follow-up.


Asunto(s)
Apéndice Atrial/cirugía , Fibrilación Atrial/cirugía , Procedimientos Quirúrgicos Cardíacos , Dispositivos de Protección Embólica , Accidente Cerebrovascular/prevención & control , Trombosis/cirugía , Anciano , Ecocardiografía Transesofágica , Femenino , Humanos , Masculino , Estudios Prospectivos , Dispositivo Oclusor Septal
6.
Artif Organs ; 46(8): 1608-1615, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35292988

RESUMEN

BACKGROUND: Ventricular arrhythmias (VAs) are observed in 25%-50% of continuous-flow left ventricular assist device (CF-LVAD) recipients, but their role on mortality is debated. METHODS: Sixty-nine consecutive patients with a CF-LVAD were retrospectively analyzed. Study endpoints were death and occurrence of first episode of VAs post CF-LVAD implantation. Early VAs were defined as VAs in the first month after CF-LVAD implantation. RESULTS: During a median follow-up of 29.0 months, 19 patients (27.5%) died and 18 patients (26.1%) experienced VAs. Three patients experienced early VAs, and one of them died. Patients with cardiac resynchronization therapy (CRT-D) showed a trend toward more VAs (p = 0.076), compared to patients without CRT-D; no significant difference in mortality was found between patients with and without CRT-D (p = 0.63). Patients with biventricular (BiV) pacing ≥98% experienced more frequently VAs (p = 0.046), with no difference in mortality (p = 0.56), compared to patients experiencing BiV pacing <98%. There was no difference in mortality among patients with or without VAs after CF-LVAD [5 patients (27.8%) vs. 14 patients (27.5%), p = 0.18)], and patients with or without previous history of VAs (p = 0.95). Also, there was no difference in mortality among patients with a different timing of implant of implantable cardioverter-defibrillator (ICD), before and after CF-LVAD (p = 0.11). CONCLUSIONS: VAs in CF-LVAD are a common clinical problem, but they do not impact mortality. Timing of ICD implantation does not have a significant impact on patients' survival. Patients with BiV pacing ≥98% experienced more frequently VAs.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Corazón Auxiliar , Arritmias Cardíacas/epidemiología , Arritmias Cardíacas/etiología , Arritmias Cardíacas/terapia , Terapia de Resincronización Cardíaca/efectos adversos , Insuficiencia Cardíaca/cirugía , Corazón Auxiliar/efectos adversos , Humanos , Estudios Retrospectivos , Resultado del Tratamiento
7.
J Cardiovasc Electrophysiol ; 32(5): 1337-1345, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33682256

RESUMEN

BACKGROUND: Ventricular arrhythmias (VAs) are rare in pediatric patients, especially in absence of structural heart disease (SHD). Few data are available regarding the invasive VAs treatment with catheter ablation (CA) in pediatric patients and predictors of outcomes have not been fully investigated. OBJECTIVE: To describe the clinical presentation, procedural characteristics, and outcomes in pediatric patients undergoing CA for VAs. METHODS: Eighty-one consecutive pediatric patients (58 male [72%], 15.5 ± 2.2 years) treated by CA for ventricular tachycardia (VT) or premature ventricular beats (PVBs) were retrospectively evaluated. Study endpoints were VAs recurrence and mortality for any cause. RESULTS: Ninety-five procedures were performed in 81 patients, 52 (55%) PVBs and 43 (45%) VT ablations. During a follow-up of 35.0 months (interquartile range = 13.0-71.0), 14 patients (14.7%) had a VA recurrence: 11 (33.3%) patients treated with CA for VT and 3 (6.2%) patients treated for PVBs (p < .001). One patient (1%) died 26 months after the procedure during an electrical storm. Patients with SHD had higher VAs recurrence rate, as compared with idiopathic VAs (pairwise log-rank p < .001). Patients treated with CA for VT had higher VA recurrence rate, as compared with PVB patients (pairwise log-rank p = .002). At Cox multivariate analysis only SHD was an independent predictor of VAs recurrence (hazard ratio = 5.56, 95% confidence interval = 2.68-11.54, p < .001). CONCLUSION: CA of VAs is effective and safe in a pediatric population. CA of idiopathic and fascicular VAs are associated with lower recurrence rate, than VAs in the setting of SHD.


Asunto(s)
Ablación por Catéter , Taquicardia Ventricular , Ablación por Catéter/efectos adversos , Niño , Humanos , Masculino , Recurrencia , Estudios Retrospectivos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirugía , Resultado del Tratamiento
8.
Rev Cardiovasc Med ; 22(4): 1383-1392, 2021 Dec 22.
Artículo en Inglés | MEDLINE | ID: mdl-34957778

RESUMEN

Ventricular arrhythmias still represent an important cause of morbidity and mortality, especially in patients with heart failure and reduced left ventricular ejection fraction. Amiodarone is a Class III Vaughan-Williams anti-arrhythmic drug widely used in ventricular arrhythmias for its efficacy and low pro-arrhythmogenic effect. On the other hand, a significant limitation in its use is represented by toxicity. In this review, the pharmacology of the drug is discussed to provide the mechanistic basis for its clinical use. Moreover, all the latest evidence on its role in different clinical settings is provided, including the prevention of sudden cardiac death, implanted cardioverter defibrillators, ischemic and non-ischemic cardiomyopathies. A special focus is placed on everyday clinical practice learning points, such as dosage, indications, and contraindications from the latest guidelines.


Asunto(s)
Amiodarona , Desfibriladores Implantables , Amiodarona/efectos adversos , Antiarrítmicos/efectos adversos , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/tratamiento farmacológico , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables/efectos adversos , Humanos , Volumen Sistólico , Función Ventricular Izquierda
9.
Cell Mol Neurobiol ; 41(1): 185-190, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-32211996

RESUMEN

Motoneuron activity is modulated by histamine receptors. While H1 and H2 receptors have been widely explored, H3 histamine receptors (H3Rs) have not been sufficiently characterized. This paper targets the effects of the selective activation of H3Rs and their expression on the membranes of large ventral horn cells. The application of selective pharmacological agents to spinal cords isolated from neonatal rats was used to identify the presence of functional H3Rs on the membrane of physiologically identified lumbar motoneurons. Intra and extracellular recordings revealed that H3R agonist, α-methylhistamine, depolarized both single motoneurons and ventral roots, even in the presence of tetrodotoxin, an effect prevented by H3R antagonist, thioperamide. Finally, immunohistochemistry located the expression of H3Rs on a subpopulation of large cells in lamina IX. This study identifies H3Rs as a new exploitable pharmacological target against motor disturbances.


Asunto(s)
Neuronas Motoras/metabolismo , Receptores Histamínicos/metabolismo , Asta Ventral de la Médula Espinal/metabolismo , Animales , Metilhistaminas/farmacología , Neuronas Motoras/efectos de los fármacos , Ratas , Asta Ventral de la Médula Espinal/efectos de los fármacos
10.
Europace ; 22(12): 1841-1847, 2020 12 23.
Artículo en Inglés | MEDLINE | ID: mdl-32995866

RESUMEN

AIMS: To chart the effect of the COVID-19 pandemic on the activity of interventional electrophysiology services in affected regions. METHODS AND RESULTS: We reviewed the electrophysiology laboratory records in three affected cities: Wenzhou in China, Milan in Italy, and London in the UK. We inspected catheter lab records and interviewed electrophysiologists in each centre to gather information on the impact of the pandemic on working patterns and on the health of staff members and patients. There was a striking decline in interventional electrophysiology activity in each of the centres. The decline occurred within a week of the recognition of widespread community transmission of the virus in each region and shows a striking correlation with the national figures for new diagnoses of COVID-19 in each case. During the period of restriction, workflow dropped to <5% of normal, consisting of emergency cases only. In two of three centres, electrophysiologists were redeployed to perform emergency work outside electrophysiology. Among the centres studied, only Wenzhou has seen a recovery from the restrictions in activity. Following an intense nationwide programme of public health interventions, local transmission of COVID-19 ceased to be detectable after 18 February allowing the electrophysiology service to resume with a strict testing regime for all patients. CONCLUSION: Interventional electrophysiology is vulnerable to closure in times of great social difficulty including the COVID-19 pandemic. Intense public health intervention can permit suppression of local disease transmission allowing resumption of some normal activity with stringent precautions.


Asunto(s)
COVID-19/epidemiología , Electrofisiología Cardíaca , Servicio de Cardiología en Hospital/organización & administración , Prueba de COVID-19 , China/epidemiología , Humanos , Italia/epidemiología , Londres/epidemiología , Pandemias , SARS-CoV-2 , Flujo de Trabajo
11.
J Cardiothorac Vasc Anesth ; 33(7): 1845-1851, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-30898421

RESUMEN

OBJECTIVE: To identify reliable predictors of periprocedural intensive care unit (ICU) admission after transvenous lead extraction (LE) in a high-volume center. DESIGN: Retrospective observational study. SETTING: University tertiary-care hospital. PARTICIPANTS: All patients undergoing LE at San Raffaele Scientific Institute, Milan, Italy, from 2005 to 2015. INTERVENTIONS: LE procedures were performed in the electrophysiology laboratories with a cardiac operating room on standby between the end of the morning surgical case and before the start of the afternoon surgical case. Most procedures were conducted with the patient under procedural sedation and analgesia. After LE, patients were admitted either to the ward or to the ICU. Medical history and intraprocedural data were recorded. MEASUREMENTS AND MAIN RESULTS: Of the 389 procedures performed during the study period, 50 patients (13%) were admitted to the ICU owing to persistent hemodynamic instability or intraoperative complications requiring endotracheal intubation. Complete procedural success was achieved in 370 patients (95%), and the clinical success rate was 98.4%. No deaths were recorded. Five complications requiring emergency surgery (1.3%) were reported. Preprocedural right ventricular dysfunction (odds ratio (OR) 7.41; confidence interval 1.85-29.7; p < 0.01) and the need for general anesthesia (OR 12; confidence interval 1.49-97.06; p = 0.019) were independent predictors of ICU admission. CONCLUSIONS: Preoperative identification of patients who need ICU admission after LE is crucial to increase patient safety and decrease hospital costs. Severe right ventricular dysfunction and need for general anesthesia identify patients with low cardiac reserve who are at increased risk for ICU admission after the procedure.


Asunto(s)
Remoción de Dispositivos/efectos adversos , Ecocardiografía Transesofágica , Unidades de Cuidados Intensivos , Marcapaso Artificial , Anciano , Anciano de 80 o más Años , Desfibriladores Implantables , Femenino , Hospitales de Alto Volumen , Humanos , Masculino , Persona de Mediana Edad , Admisión del Paciente , Estudios Retrospectivos
12.
Pediatr Cardiol ; 40(4): 713-718, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30666358

RESUMEN

The current approach for catheter ablation (CA) of accessory pathways (AP) includes the use of standard catheters under fluoroscopic visualization. We hypothesize that use of contact force (CF) irrigated tip catheters might increase procedural safety in pediatric patients compared to standard irrigated tip catheters, by decreasing the number of radiofrequency (RF) pulses required to obtain AP elimination. Seventy-one pediatric patients (13.7 ± 2.5 years, 45 male) with ventricular pre-excitation were enrolled in the study. CA was performed with a standard irrigated tip catheter up to June 2013 in 41 patients (Group S) and with a CF sensing irrigated tip catheter later on in 30 patients (Group CF). In the Group CF, RF was applied with a minimal CF of 5 g; CF > 35 g was avoided. Group CF procedures required less fluoroscopy (6.8 ± 4.8 min), compared to Group S (12.2 ± 10.8 min, p = 0.007). The number of RF pulses was smaller in Group CF compared to Group S (2.5 ± 2.0 vs 5.5 ± 1.9, p < 0.01). The mean CF during the effective RF pulse was 18 ± 7.7 g, force-time integral was 1040.7 ± 955.9 gs, Ablation Index was 513.0 ± 214.2. The procedure was acutely successful in 70 patients; at 12 months follow-up 2 patients had AP recurrence, one for each group. No major complications were reported. The use of CF irrigated tip catheters was associated with a smaller number of RF pulses and less fluoroscopy, as compared to mapping and ablation with standard irrigated tip catheters.


Asunto(s)
Fascículo Atrioventricular Accesorio/diagnóstico por imagen , Mapeo del Potencial de Superficie Corporal/métodos , Ablación por Catéter/métodos , Fluoroscopía/métodos , Adolescente , Estudios de Casos y Controles , Niño , Femenino , Humanos , Masculino , Síndromes de Preexcitación/cirugía , Estudios Prospectivos , Resultado del Tratamiento
13.
J Neurosci Res ; 96(5): 889-900, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-29114923

RESUMEN

Spinal motoneurons and locomotor networks are regulated by monoamines, among which, the contribution of histamine has yet to be fully addressed. The present study investigates histaminergic regulation of spinal activity, combining intra- and extracellular electrophysiological recordings from neonatal rat spinal cord in vitro preparations. Histamine dose-dependently and reversibly generated motoneuron depolarization and action potential firing. Histamine (20 µM) halved the area of dorsal root reflexes and always depolarized motoneurons. The majority of cells showed a transitory repolarization, while 37% showed a sustained depolarization maintained with intense firing. Extracellularly, histamine depolarized ventral roots (VRs), regardless of blockage of ionotropic glutamate receptors. Initial, transient glutamate-mediated bursting was synchronous among VRs, with some bouts of locomotor activity in a subgroup of preparations. After washout, the amplitude of spontaneous tonic discharges increased. No desensitization or tachyphylaxis appeared after long perfusion or serial applications of histamine. On the other hand, histamine induced single motoneuron and VR depolarization, even in the presence of tetrodotoxin (TTX). During chemically induced fictive locomotion (FL), histamine depolarized VRs. Histamine dose-dependently increased rhythm periodicity and reduced cycle amplitude until near suppression. This study demonstrates that histamine induces direct motoneuron membrane depolarization and modulation of locomotor output, indicating new potential targets for locomotor neurorehabilitation.


Asunto(s)
Histamina/farmacología , Neuronas Motoras/efectos de los fármacos , Raíces Nerviosas Espinales/efectos de los fármacos , Potenciales de Acción/efectos de los fármacos , Potenciales de Acción/fisiología , Animales , Estimulación Eléctrica , Femenino , Locomoción/efectos de los fármacos , Locomoción/fisiología , Masculino , Neuronas Motoras/metabolismo , Neuronas Motoras/fisiología , N-Metilaspartato/farmacología , Ratas , Receptores Ionotrópicos de Glutamato/metabolismo , Raíces Nerviosas Espinales/citología , Raíces Nerviosas Espinales/metabolismo , Raíces Nerviosas Espinales/fisiología , Tetrodotoxina/farmacología
15.
J Cardiovasc Electrophysiol ; 28(5): 523-530, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28185355

RESUMEN

INTRODUCTION: Patients with mitral regurgitation are increasingly treated by percutaneous implantation of a MitraClip device (Abbott Park, IL, USA). We investigate the feasibility and safety of the transmitral catheter route for catheter ablation of ventricular tachycardia (VT) in these patients. METHODS: The mitral valve with the MitraClip in situ was crossed under transesophageal 3-dimensional echocardiographic and fluoroscopic guidance using a steerable sheath for ablation of the left ventricle. RESULTS: Five patients (all males, median age 74.0 ± 16.0 years) who had previously a MitraClip implanted were referred for catheter ablation of VT. The left ventricular ejection fraction was 29.0% ± 24.0%. One patient had both an atrial septal defect and a left atrial appendage occluder device in addition to a MitraClip. The duration between MitraClip implantation and ablation was 1019.0 ± 783.0 days. After transseptal puncture, ablation catheter was successfully steered through the mitral valve with the use of fluoroscopy. A complete high-density map of the substrate in sinus rhythm could be obtained in all patients using multipolar mapping catheters. In 1 patient, mapping was carried out using a mini-basket catheter. Procedural endpoints, noninducibility of all VTs, and abolition of all late potentials were achieved in all patients. Procedure time was 255.0 ± 52.5 minute, fluoroscopy time was 23.0 ± 7.3, and the radiation dose was 61.0 ± 37.5 Gycm2 . No mitral insufficiency or worsening of regurgitation was documented after the procedure. CONCLUSIONS: This is the first report demonstrating the feasibility and safety of VT ablation in patients with a MitraClip device using the anterograde transmitral catheter route.


Asunto(s)
Ablación por Catéter , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Taquicardia Ventricular/cirugía , Potenciales de Acción , Anciano , Anciano de 80 o más Años , Ablación por Catéter/efectos adversos , Ecocardiografía Tridimensional , Ecocardiografía Transesofágica , Técnicas Electrofisiológicas Cardíacas , Estudios de Factibilidad , Femenino , Fluoroscopía , Frecuencia Cardíaca , Humanos , Italia , Masculino , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/fisiopatología , Diseño de Prótesis , Radiografía Intervencional/métodos , Sistema de Registros , Suiza , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatología , Resultado del Tratamiento
16.
J Neurosci ; 33(19): 8559-66, 2013 May 08.
Artículo en Inglés | MEDLINE | ID: mdl-23658193

RESUMEN

During overground or treadmill walking, the stance phase and cycle durations are reduced as speed increases, whereas swing phase duration remains relatively invariant. When the speed of the left and right sides is unequal, as is the case during split-belt locomotion or when walking along a circular path, adjustments in stance and swing phases are observed, which could alter the phase/cycle duration relationships. Here, we tested this hypothesis in the left and right hindlimbs of four intact and two chronic spinal-transected adult cats during tied-belt (i.e., equal left and right speeds) and split-belt (i.e., unequal left and right speeds) walking. During split-belt walking, one side (i.e., constant limb) walked at a constant speed while the other side (varying limb) varied its speed from 0.3 to 1.0 m/s. We show that the phase/cycle duration relationships differed in both hindlimbs concurrently during split-belt walking. Specifically, the slope of the phase/cycle duration relationships for the stance/extension phase increased in the varying limb from tied-belt to split-belt walking, whereas that of the swing/flexion phase decreased. In contrast, in the constant limb, the slope of the phase/cycle duration relationships for the stance/extension phase decreased, whereas that of the swing/flexion phase increased. The results were qualitatively similar in intact and spinal-transected cats, indicating that the modulation was mediated within the spinal cord. In conclusion, we propose that neuronal networks within the spinal cord that control left and right hindlimb locomotion can differentially and simultaneously modulate phase variations when the two sides walk at different speeds.


Asunto(s)
Lateralidad Funcional/fisiología , Locomoción/fisiología , Traumatismos de la Médula Espinal/fisiopatología , Adaptación Fisiológica , Animales , Fenómenos Biomecánicos/fisiología , Gatos , Electromiografía , Prueba de Esfuerzo , Femenino , Miembro Posterior/fisiología , Masculino
17.
J Neurophysiol ; 111(9): 1885-902, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24523521

RESUMEN

It is well established that stance duration changes more than swing duration for a given change in cycle duration. Small variations in cycle duration are also observed at any given speed on a step-by-step basis. To evaluate the step-by-step effect of speed on phase variations, we measured the slopes of the linear regressions between the phases (i.e., stance, swing) and cycle duration during individual episodes at different treadmill speeds in five adult cats. We also determined the pattern of dominance, defined as the phase that varies most with cycle duration. We found a significant effect of speed on hindlimb phase variations, with significant differences observed between the slowest speed of 0.3 m/s compared with faster speeds. Moreover, although patterns of phase dominance were primarily stance/extensor dominated at the slowest speeds, as speed increased the patterns were increasingly categorized as covarying, whereby both stance/extensor and swing/flexor phases changed in approximately equal proportion with cycle duration. Speed significantly affected the relative duration of support periods as well as interlimb phasing between homolateral and diagonal pairs of limbs but not between homologous pairs of limbs. Speed also significantly affected the consistency of interlimb coordination on a step-by-step basis, being less consistent at the slowest speed of 0.3 m/s compared with faster speeds. We found a strong linear relationship between hindlimb phase variations and the consistency of interlimb coordination. Therefore, results show that phase variations on a step-by-step basis are modulated by speed, which appears to influence the consistency of interlimb coordination.


Asunto(s)
Extremidades/fisiología , Caminata/fisiología , Animales , Fenómenos Biomecánicos , Gatos , Extremidades/inervación , Músculo Esquelético/inervación , Músculo Esquelético/fisiología
18.
J Neurophysiol ; 112(8): 1825-37, 2014 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-25031257

RESUMEN

Stepping along curvilinear paths produces speed differences between the inner and outer limb(s). This can be reproduced experimentally by independently controlling left and right speeds with split-belt locomotion. Here we provide additional details on the pattern of the four limbs during quadrupedal split-belt locomotion in intact cats. Six cats performed tied-belt locomotion (same speed bilaterally) and split-belt locomotion where one side (constant side) stepped at constant treadmill speed while the other side (varying side) stepped at several speeds. Cycle, stance, and swing durations changed in parallel in homolateral limbs with shorter and longer stance and swing durations on the fast side, respectively, compared with the slow side. Phase variations were quantified in all four limbs by measuring the slopes of the regressions between stance and cycle durations (rSTA) and between swing and cycle durations (rSW). For a given limb, rSTA and rSW were not significantly different from one another on the constant side whereas on the varying side rSTA increased relative to tied-belt locomotion while rSW became more negative. Phase variations were similar for homolateral limbs. Increasing left-right speed differences produced a large increase in homolateral double support on the slow side, while triple-support periods decreased. Increasing left-right speed differences altered homologous coupling, homolateral coupling on the fast side, and coupling between the fast hindlimb and slow forelimb. Results indicate that homolateral limbs share similar control strategies, only certain features of the interlimb pattern adjust, and spinal locomotor networks of the left and right sides are organized symmetrically.


Asunto(s)
Locomoción/fisiología , Animales , Fenómenos Biomecánicos , Gatos , Extremidades/fisiología , Femenino , Masculino
19.
Circ Arrhythm Electrophysiol ; 17(7): e012181, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38836351

RESUMEN

BACKGROUND: Epicardial approach in ventricular tachycardia (VT) ablation is still regarded as a second-step strategy, due to the risk of complications. We evaluated the frequency that epicardial ablation targets were identified and ablation performed following pericardial access compared with unnecessary pericardial access for different VT causes and potential markers of epicardial VT. METHODS: All VT ablation procedures including epicardial approach over a 10-year period were included. First-line epicardial approach was indicated in arrhythmogenic right ventricular cardiomyopathy (ARVC) and postmyocarditis VT; in patients with idiopathic dilated cardiomyopathy (IDCM) and postmyocardial infarction, indications resulted from available imaging techniques or 12-lead VT morphology. The epicardial approach was considered useful if epicardial ablation was performed after epicardial mapping. Feasibility, complications, and long-term outcome were reported. RESULTS: Four hundred and eighty-eight subjects with a median age of 60 years (interquartile range, 47-65) and of left ventricle ejection fraction 41% (interquartile range, 30-55) underwent 626 epicardial VT ablations. Percutaneous access had a success rate of 92.2% and a complication rate of 3.6%. Overall, epicardial approach was, respectively, indicated to 11.8% of postmyocardial infarction patients, 49.5% in IDCM, 94% in myocarditis, and 90.7% in ARVC. Epicardial ablation at the first ablation attempt was performed in 9.3% of postmyocardial infarction patients, 28.8% in IDCM, 86.5% in myocarditis, and 81.3% in patients with ARVC. In first-line epicardial group, ARVC and myocarditis showed the highest odds for epicardial ablation (OR, 4.057 [95% CI, 1.299-8.937]; P=0.007; OR, 3.971 [95% CI, 1.376-11.465]; P=0.005, respectively). IDCM independently predicted unnecessary epicardial approach (OR, 2.7 [95% CI, 1.7-4.3]; P<0.001). After a follow-up of 41 months (interquartile range, 19-64), patients with IDCM experienced higher rate of recurrences and mortality compared with other causes. CONCLUSIONS: Epicardial approach is integral part of ablation armamentarium regardless of the VT cause, with high feasibility and low complication rate in experienced centers. Our data support its use at first ablation attempt in VTs related to ARVC and myocarditis.


Asunto(s)
Ablación por Catéter , Mapeo Epicárdico , Pericardio , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/cirugía , Taquicardia Ventricular/fisiopatología , Taquicardia Ventricular/diagnóstico , Masculino , Persona de Mediana Edad , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Femenino , Resultado del Tratamiento , Anciano , Pericardio/cirugía , Pericardio/fisiopatología , Centros de Atención Terciaria , Factores de Tiempo , Estudios Retrospectivos , Estudios de Factibilidad , Displasia Ventricular Derecha Arritmogénica/cirugía , Displasia Ventricular Derecha Arritmogénica/complicaciones , Displasia Ventricular Derecha Arritmogénica/fisiopatología , Displasia Ventricular Derecha Arritmogénica/diagnóstico , Factores de Riesgo , Recurrencia , Cardiomiopatía Dilatada/cirugía , Cardiomiopatía Dilatada/complicaciones , Cardiomiopatía Dilatada/fisiopatología , Cardiomiopatía Dilatada/diagnóstico
20.
Updates Surg ; 2024 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-38689199

RESUMEN

Uterine myomas are the most common gynecological disease in reproductive-aged women, present several symptoms, and require effective medical and/or surgical strategies. This study aimed to compare robotic-assisted laparoscopic myomectomy (RALM) with laparoscopic myomectomy (LM) in terms of operative times, intraoperative estimated blood loss, pre- and post-hemoglobin levels drop, and length of hospital stay. Data from 50 clinical records (25 RALM in Group A and 25 LM in Group B) of patients with uterine fibroids were collected from December 2022 to December 2023 at Gynecological Unit of DAI Materno-Infantile Federico II in Naples, Italy. Patients aged 30-49 years with symptomatic fibroids were included. Data on peri-operative outcomes, including operative time for myomectomy (OTM), overall operative time (OOT), intraoperative estimated blood loss (EBL), pre- and post-operative hemoglobin levels, and length of hospital stay were analyzed. The OTM in the presence of > 5 myomas was 59 [52-65] vs 69 min [61-96] (p < 0.001) for RALM and LM groups, respectively. Moreover, also in presence of ≤ 5 myomas, a difference was observed in the RALM group 48[43-55] compared to the LM group 53[50-61] min (p = 0.07). The OOT was also statistically significant for Group A compared to Group B (83[65-93] vs 72[56-110] min, p < 0.001). There were no significant differences between the two groups in terms of pre- and post-operative hemoglobin levels and EBL (p = 0.178). Group A demonstrated a notably shorter hospital stay 1.2 [1-2] days compared to Group B 2.9[3-3.75] days (p = 0.007). Our study suggests potential advantages of RALM over LM in terms of reduced operative times and shorter hospital stays. The standardized approach and extensive surgical experience likely contributed to the favorable outcomes of RALM.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA