Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 77
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Epilepsia ; 65(2): 378-388, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38036450

RESUMEN

OBJECTIVE: Home monitoring of 3-Hz spike-wave discharges (SWDs) in patients with refractory absence epilepsy could improve clinical care by replacing the inaccurate seizure diary with objective counts. We investigated the use and performance of the Sensor Dot (Byteflies) wearable in persons with absence epilepsy in their home environment. METHODS: Thirteen participants (median age = 22 years, 11 female) were enrolled at the university hospitals of Leuven and Freiburg. At home, participants had to attach the Sensor Dot and behind-the-ear electrodes to record two-channel electroencephalogram (EEG), accelerometry, and gyroscope data. Ground truth annotations were created during a visual review of the full Sensor Dot recording. Generalized SWDs were annotated if they were 3 Hz and at least 3 s on EEG. Potential 3-Hz SWDs were flagged by an automated seizure detection algorithm, (1) using only EEG and (2) with an additional postprocessing step using accelerometer and gyroscope to discard motion artifacts. Afterward, two readers (W.V.P. and L.S.) reviewed algorithm-labeled segments and annotated true positive detections. Sensitivity, precision, and F1 score were calculated. Patients had to keep a seizure diary and complete questionnaires about their experiences. RESULTS: Total recording time was 394 h 42 min. Overall, 234 SWDs were captured in 11 of 13 participants. Review of the unimodal algorithm-labeled recordings resulted in a mean sensitivity of .84, precision of .93, and F1 score of .89. Visual review of the multimodal algorithm-labeled segments resulted in a similar F1 score and shorter review time due to fewer false positive labels. Participants reported that the device was comfortable and that they would be willing to wear it on demand of their neurologist, for a maximum of 1 week or with intermediate breaks. SIGNIFICANCE: The Sensor Dot improved seizure documentation at home, relative to patient self-reporting. Additional benefits were the short review time and the patients' device acceptance due to user-friendliness and comfortability.


Asunto(s)
Epilepsia Refractaria , Epilepsia Tipo Ausencia , Dispositivos Electrónicos Vestibles , Adulto , Femenino , Humanos , Adulto Joven , Electrodos , Electroencefalografía/métodos , Convulsiones/diagnóstico , Masculino
2.
Epilepsia ; 2024 Oct 07.
Artículo en Inglés | MEDLINE | ID: mdl-39373185

RESUMEN

OBJECTIVE: Wearable nonelectroencephalographic biosignal recordings captured from the wrist offer enormous potential for seizure monitoring. However, signal quality remains a challenging factor affecting data reliability. Models trained for seizure detection depend on the quality of recordings in peri-ictal periods in performing a feature-based separation of ictal periods from interictal periods. Thus, this study aims to investigate the effect of epileptic seizures on signal quality, ensuring accurate and reliable monitoring. METHODS: This study assesses the signal quality of wearable data during peri-ictal phases of generalized tonic-clonic and focal to bilateral tonic-clonic seizures (TCS), focal motor seizures (FMS), and focal nonmotor seizures (FNMS). We evaluated accelerometer (ACC) activity and the signal quality of electrodermal activity (EDA) and blood volume pulse (BVP) data. Additionally, we analyzed the influence of peri-ictal movements as assessed by ACC (ACC activity) on signal quality and examined intraictal subphases of focal to bilateral TCS. RESULTS: We analyzed 386 seizures from 111 individuals in three international epilepsy monitoring units. BVP signal quality and ACC activity levels differed between all seizure types. We found the largest decrease in BVP signal quality and increase in ACC activity when comparing the ictal phase to the pre- and postictal phases for TCS. Additionally, ACC activity was strongly negatively correlated with BVP signal quality for TCS and FMS, and weakly for FNMS. Intraictal analysis revealed that tonic and clonic subphases have the lowest BVP signal quality and the highest ACC activity. SIGNIFICANCE: Motor elements of seizures significantly impair BVP signal quality, but do not have significant effect on EDA signal quality, as assessed by wrist-worn wearables. The results underscore the importance of signal quality assessment methods and careful selection of robust modalities to ensure reliable seizure detection. Future research is needed to explain whether seizure detection models' decisions are based on signal responses induced by physiological processes as opposed to artifacts.

3.
Epilepsia ; 65(3): 651-663, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38258618

RESUMEN

OBJECTIVE: We aimed to assess the ability of semiautomated electric source imaging (ESI) from long-term video-electroencephalographic (EEG) monitoring (LTM) to determine the epileptogenicity of temporopolar encephaloceles (TEs) in patients with temporal lobe epilepsy. METHODS: We conducted a retrospective study involving 32 temporal lobe epilepsy patients with TEs as potentially epileptogenic lesions in structural magnetic resonance imaging scans. Findings were validated through invasive intracerebral stereo-EEG in six of 32 patients and postsurgical outcome after tailored resection of the TE in 17 of 32 patients. LTM (mean duration = 6 days) was performed using the 10/20 system with additional T1/T2 for all patients and sphenoidal electrodes in 23 of 32 patients. Semiautomated detection and clustering of interictal epileptiform discharges (IEDs) were carried out to create IED types. ESI was performed on the averages of the two most frequent IED types per patient, utilizing individual head models, and two independent inverse methods (sLORETA [standardized low-resolution brain electromagnetic tomography], MUSIC [multiple signal classification]). ESI maxima concordance and propagation in spatial relation to TEs were quantified for sources with good signal quality (signal-to-noise ratio > 2, explained signal > 60%). RESULTS: ESI maxima correctly colocalized with a TE in 20 of 32 patients (62.5%) either at the onset or half-rising flank of at least one IED type per patient. ESI maxima showed propagation from the temporal pole to other temporal or extratemporal regions in 14 of 32 patients (44%), confirming propagation originating in the area of the TE. The findings from both inverse methods validated each other in 14 of 20 patients (70%), and sphenoidal electrodes exhibited the highest signal amplitudes in 17 of 23 patients (74%). The concordance of ESI with the TE predicted a seizure-free postsurgical outcome (Engel I vs. >I) with a diagnostic odds ratio of 2.1. SIGNIFICANCE: Semiautomated ESI from LTM often successfully identifies the epileptogenicity of TEs and the IED onset zone within the area of the TEs. Additionally, it shows potential predictive power for postsurgical outcomes in these patients.


Asunto(s)
Epilepsia del Lóbulo Temporal , Humanos , Epilepsia del Lóbulo Temporal/complicaciones , Epilepsia del Lóbulo Temporal/diagnóstico por imagen , Epilepsia del Lóbulo Temporal/cirugía , Electroencefalografía/métodos , Encefalocele/complicaciones , Encefalocele/diagnóstico por imagen , Estudios Retrospectivos , Lóbulo Temporal/diagnóstico por imagen , Lóbulo Temporal/cirugía , Imagen por Resonancia Magnética
4.
Brain Topogr ; 38(1): 10, 2024 Oct 22.
Artículo en Inglés | MEDLINE | ID: mdl-39436471

RESUMEN

To date, it is largely unknown how frequency range of neural oscillations measured with EEG is related to functional connectivity. To address this question, we investigated frequency-dependent directed functional connectivity among the structures of mesial and anterior temporal network including amygdala, hippocampus, temporal pole and parahippocampal gyrus in the living human brain. Intracranial EEG recording was obtained from 19 consecutive epilepsy patients with normal anterior mesial temporal MR imaging undergoing intracranial presurgical epilepsy diagnostics with multiple depth electrodes. We assessed intratemporal bidirectional functional connectivity using several causality measures such as Granger causality (GC), directed transfer function (DTF) and partial directed coherence (PDC) in a frequency-specific way. In order to verify the obtained results, we compared the spontaneous functional networks with intratemporal effective connectivity evaluated by means of SPES (single pulse electrical stimulation) method. The overlap with the evoked network was found for the functional connectivity assessed by the GC method, most prominent in the higher frequency bands (alpha, beta and low gamma), yet vanishing in the lower frequencies. Functional connectivity assessed by means of DTF and PCD obtained a similar directionality pattern with the exception of connectivity between hippocampus and parahippocampal gyrus which showed opposite directionality of predominant information flow. Whereas previous connectivity studies reported significant divergence between spontaneous and evoked networks, our data show the role of frequency bands for the consistency of functional and evoked intratemporal directed connectivity. This has implications for the suitability of functional connectivity methods in characterizing local brain circuits.


Asunto(s)
Electrocorticografía , Humanos , Masculino , Femenino , Adulto , Electrocorticografía/métodos , Adulto Joven , Epilepsia/fisiopatología , Epilepsia/diagnóstico por imagen , Lóbulo Temporal/fisiología , Lóbulo Temporal/fisiopatología , Lóbulo Temporal/diagnóstico por imagen , Red Nerviosa/fisiología , Red Nerviosa/diagnóstico por imagen , Persona de Mediana Edad , Imagen por Resonancia Magnética/métodos , Vías Nerviosas/fisiología , Vías Nerviosas/fisiopatología , Ritmo Gamma/fisiología , Electroencefalografía/métodos , Ritmo alfa/fisiología , Encéfalo/fisiología , Encéfalo/fisiopatología , Encéfalo/diagnóstico por imagen , Adolescente , Mapeo Encefálico/métodos
5.
Epilepsia ; 63(7): 1619-1629, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35357698

RESUMEN

OBJECTIVES: High counts of averaged interictal epileptiform discharges (IEDs) are key components of accurate interictal electric source imaging (ESI) in patients with focal epilepsy. Automated detections may be time-efficient, but they need to identify the correct IED types. Thus we compared semiautomated and automated detection of IED types in long-term video-EEG (electroencephalography) monitoring (LTM) using an extended scalp EEG array and short-term high-density EEG (hdEEG) with visual detection of IED types and the seizure-onset zone (SOZ). METHODS: We prospectively recruited consecutive patients from four epilepsy centers who underwent both LTM with 40-electrode scalp EEG and short-term hdEEG with 256 electrodes. Only patients with a single circumscribed SOZ in LTM were included. In LTM and hdEEG, IED types were identified visually, semiautomatically and automatically. Concordances of semiautomated and automated detections in LTM and hdEEG, as well as visual detections in hdEEG, were compared against visually detected IED types and the SOZ in LTM. RESULTS: Fifty-two of 62 patients with LTM and hdEEG were included. The most frequent IED types per patient, detected semiautomatically and automatically in LTM and visually in hdEEG, were significantly concordant with the most frequently visually identified IED type in LTM and the SOZ. Semiautomated and automated detections of IED types in hdEEG were significantly concordant with visually identified IED types in LTM, only when IED types with more than 50 detected single IEDs were selected. The threshold of 50 detected IED in hdEEG was reached in half of the patients. For all IED types per patient, agreement between visual and semiautomated detections in LTM was high. SIGNIFICANCE: Semiautomated and automated detections of IED types in LTM show significant agreement with visually detected IED types and the SOZ. In short-term hdEEG, semiautomated detections of IED types are concordant with visually detected IED types and the SOZ in LTM if high IED counts were detected.


Asunto(s)
Epilepsias Parciales , Cuero Cabelludo , Electroencefalografía/métodos , Epilepsias Parciales/diagnóstico , Humanos , Imagen por Resonancia Magnética/métodos , Estudios Prospectivos , Convulsiones
6.
Epilepsia ; 2022 Apr 20.
Artículo en Inglés | MEDLINE | ID: mdl-35441703

RESUMEN

This study describes a generalized cross-patient seizure-forecasting approach using recurrent neural networks with ultra-long-term subcutaneous EEG (sqEEG) recordings. Data from six patients diagnosed with refractory epilepsy and monitored with an sqEEG device were used to develop a generalized algorithm for seizure forecasting using long short-term memory (LSTM) deep-learning classifiers. Electrographic seizures were identified by a board-certified epileptologist. One-minute data segments were labeled as preictal or interictal based on their relationship to confirmed seizures. Data were separated into training and testing data sets, and to compensate for the unbalanced data ratio in training, noise-added copies of preictal data segments were generated to expand the training data set. The mean and standard deviation (SD) of the training data were used to normalize all data, preserving the pseudo-prospective nature of the analysis. Different architecture classifiers were trained and tested using a leave-one-patient-out cross-validation method, and the area under the receiver-operating characteristic (ROC) curve (AUC) was used to evaluate the performance classifiers. The importance of each input signal was evaluated using a leave-one-signal-out method with repeated training and testing for each classifier. Cross-patient classifiers achieved performance significantly better than chance in four of the six patients and an overall mean AUC of 0.602 ± 0.126 (mean ± SD). A time in warning of 37.386% ± 5.006% (mean ± std) and sensitivity of 0.691 ± 0.068 (mean ± std) were observed for patients with better than chance results. Analysis of input channels showed a significant contribution (p < .05) by the Fourier transform of signals channels to overall classifier performance. The relative contribution of input signals varied among patients and architectures, suggesting that the inclusion of all signals contributes to robustness in a cross-patient classifier. These early results show that it is possible to forecast seizures training with data from different patients using two-channel ultra-long-term sqEEG.

7.
Epilepsia ; 2022 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-35395101

RESUMEN

OBJECTIVE: One of the most disabling aspects of living with chronic epilepsy is the unpredictability of seizures. Cumulative research in the past decades has advanced our understanding of the dynamics of seizure risk. Technological advances have recently made it possible to record pertinent biological signals, including electroencephalogram (EEG), continuously. We aimed to assess whether patient-specific seizure forecasting is possible using remote, minimally invasive ultra-long-term subcutaneous EEG. METHODS: We analyzed a two-center cohort of ultra-long-term subcutaneous EEG recordings, including six patients with drug-resistant focal epilepsy monitored for 46-230 days with median 18 h/day of recorded data, totaling >11 000 h of EEG. Total electrographic seizures identified by visual review ranged from 12 to 36 per patient. Three candidate subject-specific long short-term memory network deep learning classifiers were trained offline and pseudoprospectively on preictal (1 h before) and interictal (>1 day from seizures) EEG segments. Performance was assessed relative to a random predictor. Periodicity of the final forecasts was also investigated with autocorrelation. RESULTS: Depending on each architecture, significant forecasting performance was achieved in three to five of six patients, with overall mean area under the receiver operating characteristic curve of .65-.74. Significant forecasts showed sensitivity ranging from 64% to 80% and time in warning from 10.9% to 44.4%. Overall, the output of the forecasts closely followed patient-specific circadian patterns of seizure occurrence. SIGNIFICANCE: This study demonstrates proof-of-principle for the possibility of subject-specific seizure forecasting using a minimally invasive subcutaneous EEG device capable of ultra-long-term at-home recordings. These results are encouraging for the development of a prospective seizure forecasting trial with minimally invasive EEG.

8.
Brain ; 144(10): 3078-3088, 2021 11 29.
Artículo en Inglés | MEDLINE | ID: mdl-34343264

RESUMEN

Interictal epileptiform discharges (IEDs) are a widely used biomarker in patients with epilepsy but lack specificity. It has been proposed that there are truly epileptogenic and less pathological or even protective IEDs. Recent studies suggest that highly pathological IEDs are characterized by high-frequency oscillations (HFOs). Here, we aimed to dissect these 'HFO-IEDs' at the single-neuron level, hypothesizing that the underlying mechanisms are distinct from 'non-HFO-IEDs'. Analysing hybrid depth electrode recordings from patients with temporal lobe epilepsy, we found that single-unit firing rates were higher in HFO- than in non-HFO-IEDs. HFO-IEDs were characterized by a pronounced pre-peak increase in firing, which coincided with the preferential occurrence of HFOs, whereas in non-HFO-IEDs, there was only a mild pre-peak increase followed by a post-peak suppression. Comparing each unit's firing during HFO-IEDs to its baseline activity, we found many neurons with a significant increase during the HFO component or ascending part, but almost none with a decrease. No such imbalance was observed during non-HFO-IEDs. Finally, comparing each unit's firing directly between HFO- and non-HFO-IEDs, we found that most cells had higher rates during HFO-IEDs and, moreover, identified a distinct subset of neurons with a significant preference for this IED subtype. In summary, our study reveals that HFO- and non-HFO-IEDs have different single-unit correlates. In HFO-IEDs, many neurons are moderately activated, and some participate selectively, suggesting that both types of increased firing contribute to highly pathological IEDs.


Asunto(s)
Potenciales de Acción/fisiología , Electrocorticografía/métodos , Epilepsia del Lóbulo Temporal/diagnóstico , Epilepsia del Lóbulo Temporal/fisiopatología , Neuronas/fisiología , Adulto , Electrocorticografía/instrumentación , Electrodos Implantados , Femenino , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven
9.
Sensors (Basel) ; 22(9)2022 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-35591007

RESUMEN

Focal onset epileptic seizures are highly heterogeneous in their clinical manifestations, and a robust seizure detection across patient cohorts has to date not been achieved. Here, we assess and discuss the potential of supervised machine learning models for the detection of focal onset motor seizures by means of a wrist-worn wearable device, both in a personalized context as well as across patients. Wearable data were recorded in-hospital from patients with epilepsy at two epilepsy centers. Accelerometry, electrodermal activity, and blood volume pulse data were processed and features for each of the biosignal modalities were calculated. Following a leave-one-out approach, a gradient tree boosting machine learning model was optimized and tested in an intra-subject and inter-subject evaluation. In total, 20 seizures from 9 patients were included and we report sensitivities of 67% to 100% and false alarm rates of down to 0.85 per 24 h in the individualized assessment. Conversely, for an inter-subject seizure detection methodology tested on an out-of-sample data set, an optimized model could only achieve a sensitivity of 75% at a false alarm rate of 13.4 per 24 h. We demonstrate that robustly detecting focal onset motor seizures with tonic or clonic movements from wearable data may be possible for individuals, depending on specific seizure manifestations.


Asunto(s)
Epilepsias Parciales , Epilepsia , Dispositivos Electrónicos Vestibles , Acelerometría , Electroencefalografía/métodos , Epilepsia/diagnóstico , Humanos , Convulsiones/diagnóstico
10.
Epilepsia ; 62(10): 2333-2343, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34240748

RESUMEN

OBJECTIVE: Wearable seizure detection devices could provide more reliable seizure documentation outside the hospital compared to seizure self-reporting by patients, which is the current standard. Previously, during the SeizeIT1 project, we studied seizure detection based on behind-the-ear electroencephalography (EEG). However, the obtained sensitivities were too low for practical use, because not all seizures are associated with typical ictal EEG patterns. Therefore, in this paper, we aim to develop a multimodal automated seizure detection algorithm integrating behind-the-ear EEG and electrocardiography (ECG) for detecting focal seizures. In this framework, we quantified the added value of ECG to behind-the-ear EEG. METHODS: This study analyzed three multicenter databases consisting of 135 patients having focal epilepsy and a total of 896 seizures. A patient-specific multimodal automated seizure detection algorithm was developed using behind-the-ear/temporal EEG and single-lead ECG. The EEG and ECG data were processed separately using machine learning methods. A late integration approach was applied for fusing those predictions. RESULTS: The multimodal algorithm outperformed the EEG-based algorithm in two of three databases, with an increase of 11% and 8% in sensitivity for the same false alarm rate. SIGNIFICANCE: ECG can be of added value to an EEG-based seizure detection algorithm using only behind-the-ear/temporal lobe electrodes for patients with focal epilepsy.


Asunto(s)
Epilepsias Parciales , Dispositivos Electrónicos Vestibles , Algoritmos , Electrocardiografía , Electroencefalografía/métodos , Epilepsias Parciales/diagnóstico , Humanos , Convulsiones/diagnóstico
11.
Epilepsia ; 62(8): 1820-1828, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-34250608

RESUMEN

OBJECTIVE: Ultra long-term subcutaneous electroencephalography (sqEEG) monitoring is a new modality with great potential for both health and disease, including epileptic seizure detection and forecasting. However, little is known about the long-term quality and consistency of the sqEEG signal, which is the objective of this study. METHODS: The largest multicenter cohort of sqEEG was analyzed, including 14 patients with epilepsy and 12 healthy subjects, implanted with a sqEEG device (24/7 EEG™ SubQ), and recorded from 23 to 230 days (median 42 days), with a median data capture rate of 75% (17.9 hours/day). Median power spectral density plots of each subject were examined for physiological peaks, including at diurnal and nocturnal periods. Long-term temporal trends in signal impedance and power spectral features were investigated with subject-specific linear regression models and group-level linear mixed-effects models. RESULTS: sqEEG spectrograms showed an approximate 1/f power distribution. Diurnal peaks in the alpha range (8-13Hz) and nocturnal peaks in the sigma range (12-16Hz) were seen in the majority of subjects. Signal impedances remained low, and frequency band powers were highly stable throughout the recording periods. SIGNIFICANCE: The spectral characteristics of minimally invasive, ultra long-term sqEEG are similar to scalp EEG, whereas the signal is highly stationary. Our findings reinforce the suitability of this system for chronic implantation on diverse clinical applications, from seizure detection and forecasting to brain-computer interfaces.


Asunto(s)
Electroencefalografía , Epilepsia , Epilepsia/diagnóstico , Humanos , Convulsiones/diagnóstico , Análisis Espectral , Tejido Subcutáneo
12.
Epilepsia ; 62(10): 2307-2321, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34420211

RESUMEN

The Wearables for Epilepsy And Research (WEAR) International Study Group identified a set of methodology standards to guide research on wearable devices for seizure detection. We formed an international consortium of experts from clinical research, engineering, computer science, and data analytics at the beginning of 2020. The study protocols and practical experience acquired during the development of wearable research studies were discussed and analyzed during bi-weekly virtual meetings to highlight commonalities, strengths, and weaknesses, and to formulate recommendations. Seven major essential components of the experimental design were identified, and recommendations were formulated about: (1) description of study aims, (2) policies and agreements, (3) study population, (4) data collection and technical infrastructure, (5) devices, (6) reporting results, and (7) data sharing. Introducing a framework of methodology standards promotes optimal, accurate, and consistent data collection. It also guarantees that studies are generalizable and comparable, and that results can be replicated, validated, and shared.


Asunto(s)
Epilepsia , Dispositivos Electrónicos Vestibles , Recolección de Datos , Epilepsia/diagnóstico , Humanos , Proyectos de Investigación , Convulsiones/diagnóstico
13.
Brain Topogr ; 34(3): 373-383, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33730357

RESUMEN

EEG-fMRI has gained increasing importance in epilepsy pre-surgical diagnosis. However, 40-70% of EEG-fMRI recordings in patients lack interictal epileptiform discharges (IEDs) during the scan, which could be overcome by detecting matching topography maps. We tried to validate this method in clinical settings taking various electroclinical factors into consideration. Eleven patients who had undergone EEG-fMRI during pre-surgical evaluation for drug-resistant epilepsy and who had had clinical long-term video-EEG were studied. Spike-related blood oxygen level-dependent (BOLD) maps were created using IEDs occurring during the EEG-fMRI scan. Separate maps were then generated from IEDs marked on the clinical long-term EEG recordings, which were averaged to produce topographical IED maps and correlated with the EEGs recorded inside the scanner yielding a correlation coefficient time course. Epileptogenic zones were defined by an expert panel during pre-surgical evaluation and validated by an epilepsy surgery resulting in a good outcome. Both techniques' performance was evaluated according to factors including arousal during IED recording, IED topography and lateralization, lesion type, and localization. Topography-related EEG-fMRI yielded more specific results compared to the spike-related method. Superficial lesion location and ipsilateral IED seem to result in a higher concordance of BOLD maps. The polarity of BOLD responses may be lesion-dependent, and both positive and negative BOLD changes may be associated with the irritative zone. Topography-related EEG-fMRI may show improved specificity especially for superficial lesions producing ipsilateral spikes. This method can be used as an alternative either in the absence of spikes during the simultaneous EEG-fMRI acquisition or to sharpen a diffusely activated BOLD-map.


Asunto(s)
Epilepsia Refractaria , Epilepsia , Mapeo Encefálico , Epilepsia Refractaria/diagnóstico por imagen , Epilepsia Refractaria/cirugía , Electroencefalografía , Epilepsia/diagnóstico por imagen , Epilepsia/cirugía , Humanos , Imagen por Resonancia Magnética
14.
Sensors (Basel) ; 21(18)2021 Sep 08.
Artículo en Inglés | MEDLINE | ID: mdl-34577222

RESUMEN

Photoplethysmography (PPG) as an additional biosignal for a seizure detector has been underutilized so far, which is possibly due to its susceptibility to motion artifacts. We investigated 62 focal seizures from 28 patients with electrocardiography-based evidence of ictal tachycardia (IT). Seizures were divided into subgroups: those without epileptic movements and those with epileptic movements not affecting and affecting the extremities. PPG-based heart rate (HR) derived from a wrist-worn device was calculated for sections with high signal quality, which were identified using spectral entropy. Overall, IT based on PPG was identified in 37 of 62 (60%) seizures (9/19, 7/8, and 21/35 in the three groups, respectively) and could be found prior to the onset of epileptic movements affecting the extremities in 14/21 seizures. In 30/37 seizures, PPG-based IT was in good temporal agreement (<10 s) with ECG-based IT, with an average delay of 5.0 s relative to EEG onset. In summary, we observed that the identification of IT by means of a wearable PPG sensor is possible not only for non-motor seizures but also in motor seizures, which is due to the early manifestation of IT in a relevant subset of focal seizures. However, both spontaneous and epileptic movements can impair PPG-based seizure detection.


Asunto(s)
Fotopletismografía , Dispositivos Electrónicos Vestibles , Electrocardiografía , Electroencefalografía , Frecuencia Cardíaca , Humanos , Convulsiones/diagnóstico , Procesamiento de Señales Asistido por Computador , Taquicardia
15.
Neuroimage ; 214: 116769, 2020 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-32217164

RESUMEN

The human temporal lobe is a multimodal association area which plays a key role in various aspects of cognition, particularly in memory formation and spatial navigation. Functional and anatomical connectivity of temporal structures is thus a subject of intense research, yet by far underexplored in humans due to ethical and technical limitations. We assessed intratemporal cortico-cortical interactions in the living human brain by means of single pulse electrical stimulation, an invasive method allowing mapping effective intracortical connectivity with a high spatiotemporal resolution. Eighteen subjects with normal anterior-mesial temporal MR imaging undergoing intracranial presurgical epilepsy diagnostics with multiple depth electrodes were included. The investigated structures were temporal pole, hippocampus, amygdala and parahippocampal gyrus. Intratemporal cortical connectivity was assessed as a function of amplitude of the early component of the cortico-cortical evoked potentials (CCEP). While the analysis revealed robust interconnectivity between all explored structures, a clear asymmetry in bidirectional connectivity was detected for the hippocampal network and for the connections between the temporal pole and parahippocampal gyrus. The amygdala showed bidirectional asymmetry only to the hippocampus. The provided evidence of asymmetrically weighed intratemporal effective connectivity in humans in vivo is important for understanding of functional interactions within the temporal lobe since asymmetries in the brain connectivity define hierarchies in information processing. The findings are in exact accord with the anatomical tracing studies in non-human primates and open a translational route for interventions employing modulation of temporal lobe function.


Asunto(s)
Encéfalo/fisiología , Red Nerviosa/fisiología , Adolescente , Adulto , Mapeo Encefálico/métodos , Estimulación Eléctrica , Electrocorticografía , Potenciales Evocados Somatosensoriales/fisiología , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Adulto Joven
16.
Epilepsia ; 61 Suppl 1: S25-S35, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32497269

RESUMEN

Noninvasive wearable devices have great potential to aid the management of epilepsy, but these devices must have robust signal quality, and patients must be willing to wear them for long periods of time. Automated machine learning classification of wearable biosensor signals requires quantitative measures of signal quality to automatically reject poor-quality or corrupt data segments. In this study, commercially available wearable sensors were placed on patients with epilepsy undergoing in-hospital or in-home electroencephalographic (EEG) monitoring, and healthy volunteers. Empatica E4 and Biovotion Everion were used to record accelerometry (ACC), photoplethysmography (PPG), and electrodermal activity (EDA). Byteflies Sensor Dots were used to record ACC and PPG, the Activinsights GENEActiv watch to record ACC, and Epitel Epilog to record EEG data. PPG and EDA signals were recorded for multiple days, then epochs of high-quality, marginal-quality, or poor-quality data were visually identified by reviewers, and reviewer annotations were compared to automated signal quality measures. For ACC, the ratio of spectral power from 0.8 to 5 Hz to broadband power was used to separate good-quality signals from noise. For EDA, the rate of amplitude change and prevalence of sharp peaks significantly differentiated between good-quality data and noise. Spectral entropy was used to assess PPG and showed significant differences between good-, marginal-, and poor-quality signals. EEG data were evaluated using methods to identify a spectral noise cutoff frequency. Patients were asked to rate the usability and comfort of each device in several categories. Patients showed a significant preference for the wrist-worn devices, and the Empatica E4 device was preferred most often. Current wearable devices can provide high-quality data and are acceptable for routine use, but continued development is needed to improve data quality, consistency, and management, as well as acceptability to patients.


Asunto(s)
Acelerometría/instrumentación , Epilepsia , Respuesta Galvánica de la Piel/fisiología , Monitoreo Ambulatorio/instrumentación , Fotopletismografía/instrumentación , Dispositivos Electrónicos Vestibles , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Prioridad del Paciente , Procesamiento de Señales Asistido por Computador , Adulto Joven
17.
Epilepsia ; 59(3): 650-660, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-29322500

RESUMEN

OBJECTIVE: Epilepsy is characterized by transient alterations in brain synchronization resulting in seizures with a wide spectrum of manifestations. Seizure severity and risks for patients depend on the evolution and spread of the hypersynchronous discharges. With standard visual inspection and pattern classification, this evolution could not be predicted early on. It is still unclear to what degree the seizure onset zone determines seizure severity. Such information would improve our understanding of ictal epileptic activity and the existing electroencephalogram (EEG)-based warning and intervention systems, providing specific reactions to upcoming seizure types. We investigate the possibility of predicting the future development of an epileptic seizure during the first seconds of recordings after their electrographic onset. METHODS: Based on intracranial EEG recordings of 493 ictal events from 26 patients with focal epilepsy, a set of 25 time and frequency domain features was computed using nonoverlapping 1-second time windows, from the first 3, 5, and 10 seconds of ictal EEG. Three random forest classifiers were trained to predict the future evolution of the seizure, distinguishing between subclinical events, focal onset aware and impaired awareness, and focal to bilateral tonic-clonic seizures. RESULTS: Results show that early seizure type prediction is possible based on a single EEG channel located in the seizure onset zone with correct prediction rates of 76.2 ± 14.5% for distinguishing subclinical electrographic events from clinically manifest seizures, 75 ± 16.8% for distinguishing focal onset seizures that are or are not bilateral tonic-clonic, and 71.4 ± 17.2% for distinguishing between focal onset seizures with or without impaired awareness. All predictions are above the chance level (P < .01). SIGNIFICANCE: These findings provide the basis for developing systems for specific early warning of patients and health care providers, and for targeting EEG-based closed-loop intervention approaches to electrographic patterns with a high inherent risk to become clinically manifest.


Asunto(s)
Electroencefalografía/métodos , Epilepsias Parciales/diagnóstico , Epilepsias Parciales/fisiopatología , Convulsiones/diagnóstico , Convulsiones/fisiopatología , Humanos , Valor Predictivo de las Pruebas
18.
Epilepsia ; 58(8): 1305-1315, 2017 08.
Artículo en Inglés | MEDLINE | ID: mdl-28622421

RESUMEN

OBJECTIVE: Technology for localizing epileptogenic brain regions plays a central role in surgical planning. Recent improvements in acquisition and electrode technology have revealed that high-frequency oscillations (HFOs) within the 80-500 Hz frequency range provide the neurophysiologist with new information about the extent of the epileptogenic tissue in addition to ictal and interictal lower frequency events. Nevertheless, two decades after their discovery there remain questions about HFOs as biomarkers of epileptogenic brain and there use in clinical practice. METHODS: In this review, we provide practical, technical guidance for epileptologists and clinical researchers on recording, evaluation, and interpretation of ripples, fast ripples, and very high-frequency oscillations. RESULTS: We emphasize the importance of low noise recording to minimize artifacts. HFO analysis, either visual or with automatic detection methods, of high fidelity recordings can still be challenging because of various artifacts including muscle, movement, and filtering. Magnetoencephalography and intracranial electroencephalography (iEEG) recordings are subject to the same artifacts. SIGNIFICANCE: High-frequency oscillations are promising new biomarkers in epilepsy. This review provides interested researchers and clinicians with a review of current state of the art of recording and identification and potential challenges to clinical translation.


Asunto(s)
Ondas Encefálicas/fisiología , Electroencefalografía/métodos , Epilepsia/diagnóstico , Epilepsia/fisiopatología , Guías como Asunto , Electroencefalografía/normas , Humanos
19.
Epilepsia ; 57(6): 889-95, 2016 06.
Artículo en Inglés | MEDLINE | ID: mdl-27030215

RESUMEN

OBJECTIVE: Clustered seizures are characterized by shorter than usual interseizure intervals and pose increased morbidity risk. This study examines the characteristics of seizures that cluster, with special attention to the final seizure in a cluster. METHODS: This is a retrospective analysis of long-term inpatient monitoring data from the EPILEPSIAE project. Patients underwent presurgical evaluation from 2002 to 2009. Seizure clusters were defined by the occurrence of at least two consecutive seizures with interseizure intervals of <4 h. Other definitions of seizure clustering were examined in a sensitivity analysis. Seizures were classified into three contextually defined groups: isolated seizures (not meeting clustering criteria), terminal seizure (last seizure in a cluster), and intracluster seizures (any other seizures within a cluster). Seizure characteristics were compared among the three groups in terms of duration, type (focal seizures remaining restricted to one hemisphere vs. evolving bilaterally), seizure origin, and localization concordance among pairs of consecutive seizures. RESULTS: Among 92 subjects, 77 (83%) had at least one seizure cluster. The intracluster seizures were significantly shorter than the last seizure in a cluster (p = 0.011), whereas the last seizure in a cluster resembled the isolated seizures in terms of duration. Although focal only (unilateral), seizures were shorter than seizures that evolved bilaterally and there was no correlation between the seizure type and the seizure position in relation to a cluster (p = 0.762). Frontal and temporal lobe seizures were more likely to cluster compared with other localizations (p = 0.009). Seizure pairs that are part of a cluster were more likely to have a concordant origin than were isolated seizures. Results were similar for the 2 h definition of clustering, but not for the 8 h definition of clustering. SIGNIFICANCE: We demonstrated that intracluster seizures are short relative to isolated seizures and terminal seizures. Frontal and temporal lobe seizures are more likely to cluster.


Asunto(s)
Ondas Encefálicas/fisiología , Análisis por Conglomerados , Convulsiones/fisiopatología , Adulto , Electroencefalografía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Convulsiones/patología , Factores de Tiempo , Adulto Joven
20.
Epilepsia ; 56(2): 197-206, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25556401

RESUMEN

OBJECTIVE: Interictal high frequency oscillations (HFOs) are a promising candidate as a biomarker in epilepsy as well as for defining the seizure-onset zone as for the prediction of the surgical outcome after epilepsy surgery. The purpose of the study is to investigate properties of HFOs in long-term recordings with respect to the sleep-wake cycle and anatomic regions to verify previous results based on observations from short intervals and patients mainly with temporal lobe epilepsy to the analysis of hours of recordings and focal epilepsies with extratemporal origin. METHODS: Automatic HFO detection using a radial basis function neural network detector was performed in long-term recordings of 15 presurgical patients investigated with subdural strip, grid, and depth contacts. Periods with visual marked sleep stages based on parallel scalp recordings from two consecutive nights were compared to awake intervals. Statistical analysis was based on the Kruskal-Wallis test, Mann-Whitney U-test and Spearman's rank correlations. RESULTS: HFO rates in seizure-onset contacts differed from other brain regions independent of the sleep-wake cycle. For temporal contacts, the HFO rate increased significantly with sleep stage. In addition, contacts covering the parietal lobe, including rolandic cortex, showed a significant increase of HFO rates during sleep. However, no significant HFO rate changes depending on the sleep-wake cycle were found for frontal contacts. SIGNIFICANCE: The rate of interictal HFOs predicted the SOZ with statistical significance at the group level, but properties other than the HFO rate may need to be considered to improve the diagnostic utility of HFOs. This study gives evidence that the modulation of HFO rates by states of the sleep-wake cycle has particular characteristics within different neocortical regions and in mesiotemporal structures, and contributes to the establishment of HFOs as a biomarker in epilepsy.


Asunto(s)
Ondas Encefálicas/fisiología , Epilepsia/diagnóstico , Sueño/fisiología , Vigilia/fisiología , Adolescente , Adulto , Biomarcadores/análisis , Niño , Electroencefalografía/métodos , Epilepsia/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Fases del Sueño/fisiología , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA