Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 60
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Asunto de la revista
Intervalo de año de publicación
1.
Instr Course Lect ; 72: 261-272, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36534861

RESUMEN

Unicompartmental knee arthroplasty (UKA) has become an increasingly used procedure for patients with unicompartmental knee osteoarthritis. The success of UKA relies on appropriate patient selection and patient optimization before surgery is performed. Improved prosthesis design and surgical techniques for medial and lateral and fixed and mobile bearing UKA have also contributed to improved knee biomechanics, faster recovery, and improved outcomes. Indications, factors affecting patient selection, the role of limb alignment, and the surgical pearls for fixed and mobile bearing and medial and lateral UKA are important topics for discussion.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Articulación de la Rodilla/cirugía , Osteoartritis de la Rodilla/cirugía , Diseño de Prótesis , Resultado del Tratamiento
2.
Instr Course Lect ; 72: 287-306, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36534863

RESUMEN

Total knee arthroplasty continues to evolve. It is important to review some of the current controversies and hot topics in arthroplasty. Optimal knee alignment strategy is now just a matter of debate. Mechanical, kinematic, and functional alignment and the role of robotics in achieving optimum alignment are important topics, along with fixation and outpatient knee arthroplasty.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Humanos , Fenómenos Biomecánicos , Articulación de la Rodilla/cirugía , Extremidad Inferior/cirugía , Osteoartritis de la Rodilla/cirugía
3.
J Arthroplasty ; 35(1): 127-131, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31537374

RESUMEN

BACKGROUND: Aseptic loosening remains a common cause of failure in total knee arthroplasty (TKA). There is an increased interest in using uncemented TKA to reduce this complication. Radiolucencies (RLs) following uncemented TKA can be concerning. We report on the 9-year history of RLs in patients with uncemented TKA. METHODS: Twenty-one patients (26 knees) were treated with a cruciate-retaining fully porous coated femur/tibia and cemented patella. At final follow-up, 17 patients (22 knees) were available for review. Average follow-up was 9.6 years, average age was 59.1, and average body mass index was 34.1. X-rays were taken at 6 weeks, 1 year, and at final follow-up. RLs were measured using the Knee Society scoring system and read by two separate surgeons. RESULTS: At 6 weeks, we identified RL in all patients on both the tibia and femur. The majority were beneath the tibial tray and femoral chamfer. At 1 year, 4 femurs and 4 tibias showed new RLs (<2 mm) in similar zones. Eighteen femurs and 18 tibias showed fewer or no change in RLs. At final follow-up, no new tibia or femur developed a new RL. In total, 9 of the 22 tibias and 17 of the 22 femurs had remaining RLs, all less than 2 mm and none were progressive or new. Knee Society Score averaged 92.5 (6 weeks), 95.1 (1 year), and 97.3 (final). CONCLUSION: RLs are common following uncemented TKA. Many resolve by 1 year. There does not appear to be any association between the presence of RLs and long-term follow-up function in this group of patients.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Artroplastia de Reemplazo de Rodilla/efectos adversos , Cementos para Huesos , Estudios de Seguimiento , Humanos , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/cirugía , Prótesis de la Rodilla/efectos adversos , Persona de Mediana Edad , Falla de Prótesis , Reoperación , Tibia/diagnóstico por imagen , Tibia/cirugía , Resultado del Tratamiento
4.
J Arthroplasty ; 34(7S): S262-S265, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-30979670

RESUMEN

BACKGROUND: In the setting of aseptic revision, a common question is: what should be done with the previously resurfaced patella? We report on a series of aseptic revision total knee arthroplasties (RTKA) where one or both components were revised and the patella was not. METHODS: The study group was 147 consecutive RTKA in 137 patients with a mean age of 70.1 ± 9.3 years where the patella was not revised. The average body mass index was 31.0 ± 5.4 kg/m2. Follow-up was a minimum of 5 years (range, 5 to 12 years). At final follow-up, 13 patients died and 2 patients were lost to follow-up leaving 122 patients and 130 knees available for review. Mean time from primary surgery to RTKA was 9.2 ± 5.5 years. Both components were revised in 50 knees, the femur only in 11 knees, the tibia only in 12 knees, and 57 had an isolated polyethylene revision. We found 5 patients with a mismatch between the patella and femoral components and 30 cases with patella component wear identified intraoperatively. RESULTS: At final follow-up, there were no reoperations on any patella and none were at risk of failure. There were 6 knees with a lateral patella tilt beyond 10°, but none were subluxed. Knee Society Scores averaged 85 ± 17.2 points at final follow-up. CONCLUSION: At midterm follow-up in this group of RTKA where the patella was not revised, we identified no subsequent failures of the patella. This is despite the presence of mild patella polyethylene wear and mismatched shapes in several knees. LEVEL OF EVIDENCE: III.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Rótula , Reoperación/métodos , Anciano , Anciano de 80 o más Años , Femenino , Fémur/cirugía , Estudios de Seguimiento , Humanos , Rodilla/cirugía , Articulación de la Rodilla/cirugía , Prótesis de la Rodilla , Masculino , Persona de Mediana Edad , Polietileno , Tibia/cirugía
5.
J Arthroplasty ; 32(9S): S69-S73, 2017 09.
Artículo en Inglés | MEDLINE | ID: mdl-28705543

RESUMEN

BACKGROUND: Oral multimodal analgesia for hip and knee arthroplasty is increasingly used as part of enhanced recovery protocols designed to minimize early postoperative pain and to facilitate early discharge, while minimizing undesirable side effects related to single-agent opioid administration. METHODS: This article is a review of previously published data evaluating the use of various oral medications in the management of postoperative pain after lower extremity arthroplasty and was presented as part of a symposium at the November 2016 AAHKS Annual Meeting. RESULTS: Multimodal analgesia has been shown to reduce opioid consumption and side effects, with a positive effect on both early and longer term outcomes for hip and knee arthroplasty patients. Medications directed at multiple points on the pain cascade minimize pain by different mechanisms. Suggested dosing regimens are proposed. CONCLUSION: Oral multimodal analgesia incorporating a combination of opioid and nonopioid analgesics, selective and nonselective anti-inflammatory drugs, acetaminophen, and gabapentinoids are recommended as a part of a pre-emptive approach to pain management in patients undergoing hip or knee arthroplasty. Reduction of opioid consumption and minimization of side effects are primary outcomes, and prevention of chronic pain can positively affect long-term results.


Asunto(s)
Analgesia/métodos , Analgésicos/administración & dosificación , Artroplastia de Reemplazo/efectos adversos , Manejo del Dolor/métodos , Dolor Postoperatorio/prevención & control , Acetaminofén/administración & dosificación , Analgésicos no Narcóticos/administración & dosificación , Analgésicos Opioides , Artroplastia de Reemplazo de Rodilla , Dolor Crónico , Protocolos Clínicos , Humanos , Dimensión del Dolor , Dolor Postoperatorio/etiología
6.
Clin Orthop Relat Res ; 473(12): 3894-902, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26443774

RESUMEN

BACKGROUND: Greater levels of self-reported pain, pain catastrophizing, and depression have been shown to be associated with persistent pain and functional limitation after surgeries such as TKA. It would be useful for clinicians to be able to measure these factors efficiently. QUESTIONS/PURPOSES: We asked: (1) What is the association of whole-body pain with osteoarthritis (OA)-related knee pain, function, pain catastrophizing, and mental health? (2) What is the sensitivity and specificity for different cutoffs for body pain diagram region categories in relation to pain catastrophizing? METHODS: Patients (n = 267) with knee OA undergoing elective TKA at one academic center and two community orthopaedic centers were enrolled before surgery in a prospective cohort study. Questionnaires included the WOMAC Pain and Function Scales, Pain Catastrophizing Scale (PCS), Mental Health Inventory-5 (MHI-5), and a pain body diagram. The diagram documents pain in 19 anatomic areas. Based on the distribution of the anatomic areas, we established six different body regions. Our analyses excluded the index (surgically treated) knee. Linear regression was used to evaluate the association between the total number of nonindex painful sites on the whole-body pain diagram and measures of OA-related pain and function, mental health, and pain catastrophizing. Generalized linear regression was used to evaluate the association between the number of painful nonindex body regions (categorized as 0; 1-2; or 3-6) with our measures of interest. All models were adjusted for age, sex, and number of comorbid conditions. The cohort included 63% females and the mean age was 66 years (SD, 9 years). With removal of the index knee, the median pain diagram score was 2 (25(th), 75(th) percentiles, 1, 4) with a range of 0 to 15. The median number of painful body regions was 2 (25(th), 75(th) percentiles, 1, 3). RESULTS: After adjusting for age, sex, and number of comorbid conditions, we found modest associations between painful body region categories and mean scores for WOMAC physical function (r = 0.22, p < 0.001), WOMAC pain (r = 0.20, p = 0.001), MHI-5 (r = -0.31, p < 0.001), and PCS (r = 0.27, p < 0.001). A nonindex body pain region score greater than 0 had 100% (95% CI, 75%-100%) sensitivity for a pain catastrophizing score greater than 30 but a specificity of just 23% (95% CI, 18%-29%) . A score of 3 or greater had greater specificity (73%; 95% CI, 66%-79%) but lower sensitivity (53%; 95% CI, 27%-78%). CONCLUSIONS: We found modest associations between the number of painful sites on a whole-body pain diagram and the number of painful body regions and measures of OA-related pain, function, pain catastrophizing, and mental health. Patients with higher self-reported body pain region scores might benefit from further evaluation for depression and pain catastrophizing. LEVEL OF EVIDENCE: Level III, therapeutic study.


Asunto(s)
Artralgia/psicología , Catastrofización/psicología , Salud Mental , Osteoartritis de la Rodilla/psicología , Centros Médicos Académicos , Anciano , Artralgia/diagnóstico , Artralgia/etiología , Artroplastia de Reemplazo de Rodilla , Catastrofización/diagnóstico , Catastrofización/etiología , Femenino , Humanos , Modelos Lineales , Masculino , Persona de Mediana Edad , Osteoartritis de la Rodilla/complicaciones , Osteoartritis de la Rodilla/diagnóstico , Osteoartritis de la Rodilla/cirugía , Dimensión del Dolor , Estudios Prospectivos , Factores de Riesgo , Encuestas y Cuestionarios , Estados Unidos
7.
J Surg Orthop Adv ; 24(4): 252-6, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26731390

RESUMEN

Previous work, now nearly 30 years dated, is frequently cited as the "gold standard" for the indications and contraindications for medial unicompartmental knee arthroplasty (UKA). The purpose of this article is to review current literature on the indications and contraindications to UKA and develop a consensus statement based on those data. Six surgeons with a combined experience of performing more than 8,000 partial knee arthroplasties were surveyed. Surgeons then participated in a discussion, emerging proposal, collaborative modification, and final consensus phase. The final consensus on primary indications and contraindications is presented. Notably, the authors provide consensus on previous contraindications, which are no longer considered to be contraindications. The authors provide an updated and concise review of the current indications and contraindications for medial UKA using scientifically based consensus-building methodology.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Investigación Biomédica/métodos , Competencia Clínica , Consenso , Toma de Decisiones , Osteoartritis de la Rodilla/cirugía , Complicaciones Posoperatorias/prevención & control , Factores de Edad , Humanos , Prótesis de la Rodilla
8.
Transfusion ; 54(1): 26-30, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23521109

RESUMEN

BACKGROUND: Tranexamic acid (TXA) is an antifibrinolytic that reduces blood loss and transfusion rates in total joint arthroplasty. Blood loss and allogenic transfusion rates have not been well studied in patients receiving TXA and undergoing bilateral staged total knee arthroplasty (TKA). The purpose was to evaluate the effect of TXA on blood loss, hemoglobin (Hb) changes, and transfusion in patients undergoing staged bilateral TKA. STUDY DESIGN AND METHODS: The authors compared 51 patients undergoing staged bilateral TKA who received TXA (2 g; subjects) with 70 who did not (controls). There were no significant differences between the groups in terms of demographics or preoperative Hb. For each TKA, 1 g of TXA was administered intravenously 15 minutes before incision and 1 g was administered intravenously at tourniquet release. Blood loss, Hb levels, and transfusions were recorded. Statistical analyses were performed using computer software. Significance was set at 0.05. RESULTS: Subjects had a significantly lower (p < 0.001) mean (±SD) blood loss (373.8 ± 264.6 mL vs. 871.6 ± 457.7 mL), significantly higher (p < 0.005) Hb levels on Postoperative Days 1 and 2, and a significantly lower (p < 0.001) mean (±SD) number of transfused allogenic blood units (0.60 ± 0.84 units vs. 1.53 ± 1.30 units). CONCLUSIONS: TXA reduces blood loss, improves postoperative Hb, and decreases the allogenic blood transfusion requirements for patients undergoing bilateral staged TKA. TXA is an option for patients choosing bilateral staged TKA to decrease the risks associated with blood transfusion or when autologous blood is not available.


Asunto(s)
Antifibrinolíticos/uso terapéutico , Artroplastia de Reemplazo de Rodilla/efectos adversos , Transfusión Sanguínea/estadística & datos numéricos , Hemorragia Posoperatoria/prevención & control , Ácido Tranexámico/uso terapéutico , Anciano , Femenino , Humanos , Rodilla/fisiología , Masculino , Persona de Mediana Edad , Rango del Movimiento Articular/fisiología , Estudios Retrospectivos
9.
Clin Orthop Relat Res ; 472(1): 194-205, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23568680

RESUMEN

BACKGROUND: The Total Knee Arthroplasty (TKA) Complications Workgroup of the Knee Society developed a standardized list and definitions of complications associated with TKA. Twenty-two complications and adverse events believed important for reporting outcomes of TKA were identified. The Editorial Board of Clinical Orthopaedics and Related Research (®), the Executive Board of the Knee Society, and the members of the Knee Society TKA Complications Workgroup came to the conclusion that reporting of a list of TKA adverse events and complications would be more valuable if they were stratified using a validated classification system. QUESTIONS/PURPOSES: The purpose of this article was to stratify the previously published standardized list of TKA adverse events and complications. METHODS: A modified version of the Sink adaptation of the Clavien-Dindo Surgical Complication Classification was applied to the list of standardized TKA complications and adverse events. RESULTS: The proposed stratified classifications of TKA complications were reviewed and endorsed by the Knee Society. CONCLUSIONS: Stratification of TKA complications will allow more in-depth and detailed outcome reporting for surgeons, hospitals, third-party payers, government agencies, joint replacement registries, and orthopaedic researchers. This improvement in reporting of TKA complications will also improve the quality of orthopaedic literature.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/efectos adversos , Articulación de la Rodilla/cirugía , Complicaciones Posoperatorias/clasificación , Humanos , Rodilla/cirugía , Sistema de Registros , Encuestas y Cuestionarios
10.
J Arthroplasty ; 29(7): 1398-411, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24582161

RESUMEN

A systematic review appraising the clinical performance and safety of the primary SIGMA modular knee system (DePuy-Synthes, Warsaw, Ind.) found 5 registry reports and 53 journal publications reporting survivorship or postoperative increase in Knee Society scores on 241632 primary SIGMA knee arthroplasties. Pooled data from national joint registries and clinical studies on primary SIGMA knee survivorship were comparable. Both were higher than for all other knees in 5 national joint registries up to 5 years. Compared with pooled data from 2 independent systematic reviews of primary non-SIGMA knees, the SIGMA system provided comparable postoperative changes in Knee Society knee score and a nonsignificant trend of higher postoperative changes in Knee Society function score. This finding suggests that this knee system provides excellent durable results.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Articulación de la Rodilla/cirugía , Diseño de Prótesis , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Humanos , Articulación de la Rodilla/fisiopatología , Prótesis de la Rodilla , Masculino , Persona de Mediana Edad , Periodo Posoperatorio , Sistema de Registros , Reoperación , Tasa de Supervivencia , Resultado del Tratamiento
11.
J Arthroplasty ; 29(2): 343-7, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23993343

RESUMEN

Patient specific instrumentation (PSI) was developed to increase total knee arthroplasty (TKA) accuracy and efficiency. The study purpose was to compare immediate post-operative mechanical alignment, achieved using PSI, with conventional and computer assisted surgery (CAS) instruments in high volume TKA practices. This prospective, multicenter, non-randomized study accrued 66 TKA patients using PSI. A computed tomography (CT) based algorithm was used to develop the surgical plan. Sixty-two percent were females, 99% were diagnosed with osteoarthritis, average age at surgery was 66 years, and 33 was the average body mass index. A historical control group was utilized that underwent TKA using conventional instruments (n=86) or CAS (n=81), by the same set of surgeons. Postoperative mechanical alignment was comparable across the groups. Operative time mean and variance were significant.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/instrumentación , Desviación Ósea/prevención & control , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Osteoartritis de la Rodilla/cirugía , Estudios Prospectivos , Cirugía Asistida por Computador , Factores de Tiempo
12.
Orthopedics ; 47(3): 161-166, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38285554

RESUMEN

BACKGROUND: Aseptic loosening continues to be a major cause of failure of total knee arthroplasty (TKA). Although cemented fixation remains the gold standard, there is renewed interest in cementless fixation as a means of decreasing this risk via biologic fixation. The purpose of this study was to evaluate the clinical outcomes of cemented and cementless versions of a newly introduced TKA design at an average of 4 years postoperatively. MATERIALS AND METHODS: This was a retrospective case-control study of 100 primary TKAs comparing cementless vs cemented TKAs using the same cruciate-retaining implant design (ATTUNE Knee System; DePuy Synthes). Fifty patients undergoing cementless TKA with a mean age of 60.8 years (range, 48-71 years) and body mass index (BMI) of 31.6 kg/m2 (range, 23.7-41.9 kg/m2) were matched to 50 patients undergoing primary cemented TKA with a mean age of 62.7 years (range, 51-73 years) and BMI of 30.1 kg/m2 (range, 24.6-43.9 kg/m2). The mean follow-up was 4.2 years (range, 4.0-4.4 years) in the cementless group and 7.6 years (range, 7.5-7.7 years) in the cemented group. Complications, clinical outcomes using the Knee Society Score (KSS), and radiographic analyses were evaluated at final follow-up. Student's t tests were used for statistical analyses. RESULTS: There was no statistical difference in age, BMI, and preoperative KSS between the two groups (P=.12, P=.15, and P=.55, respectively). There were no complications or reoperations in either cohort. There were no statistical differences in range of motion and total KSS at final follow-up between the two groups. Final total KSS had a mean of 91.1 for the cementless group and 93.7 for the cemented group. There was no radiographic evidence of component subsidence or loosening in either cohort. CONCLUSION: When compared with its cemented counterpart, the newly introduced cementless TKA design had similar excellent clinical improvements and radiologic results at an average of 4 years of follow-up. [Orthopedics. 2024;47(3):161-166.].


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Diseño de Prótesis , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Artroplastia de Reemplazo de Rodilla/instrumentación , Persona de Mediana Edad , Anciano , Masculino , Femenino , Estudios Retrospectivos , Estudios de Casos y Controles , Resultado del Tratamiento , Cementos para Huesos/uso terapéutico , Falla de Prótesis
13.
Knee ; 49: 52-61, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38848658

RESUMEN

BACKGROUND: There is increasing use of Robotic-Assisted (RA) and personalized alignment techniques in total knee arthroplasty (TKA). The hypothesis of this study was that RA TKA would result in fewer soft-tissue releases, and that fewer soft-tissue releases would be associated with improved clinical outcomes. METHODS: A retrospective review of an internal company registry was conducted for all primary TKAs performed from Jan 1, 2014, through a database extract date of Nov 4, 2022. These were grouped by whether there was an intentional soft-tissue release performed (STR) during the surgery or not (NSTR) and whether RA was utilized. The incidence of STR was compared between RA-TKAs and those performed with manual instrumentation. Knee Society Score (KSS) and Knee Society Function Scores (KSFS) were collected at 6 months, 1 year and 2 years. Kaplan-Meier survivorship was performed. RESULTS: The incidence of STR was significantly lower for RA vs. Manual (43.81% Vs 86.62%, p < 0.0001). The TKAs with NSTR had higher KSFS compared to those with STR at 6 months (84.73 Vs. 77.51, p < 0.0001), 1 year (89.87 Vs. 83.54, p < 0.0001) and 2 years (90.09 Vs. 82.65, p < 0.0001). There was no difference in survivorship, or KSS at any time point. However, the NSTR group had improved KSS pain sub score at 2 years. CONCLUSION: The results of this observational, retrospective analysis found that the incidence of soft-tissue release was lower with RA-TKA. Further, regardless of if RA was used, avoiding releases was associated with improved KSFS and KSS pain scores through 2 years post-operatively.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Procedimientos Quirúrgicos Robotizados , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Estudios Retrospectivos , Procedimientos Quirúrgicos Robotizados/métodos , Masculino , Femenino , Anciano , Persona de Mediana Edad , Osteoartritis de la Rodilla/cirugía , Recuperación de la Función , Resultado del Tratamiento , Articulación de la Rodilla/cirugía , Articulación de la Rodilla/fisiopatología , Rango del Movimiento Articular
14.
Clin Orthop Relat Res ; 471(1): 215-20, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22810157

RESUMEN

BACKGROUND: Despite the importance of complications in evaluating patient outcomes after TKA, definitions of TKA complications are not standardized. Different investigators report different complications with different definitions when reporting outcomes of TKA. QUESTIONS/PURPOSES: We developed a standardized list and definitions of complications and adverse events associated with TKA. METHODS: In 2009, The Knee Society appointed a TKA Complications Workgroup that surveyed the orthopaedic literature and proposed a list of TKA complications and adverse events with definitions. An expert opinion survey of members of The Knee Society was used to test the applicability and reasonableness of the proposed TKA complications. For each complication, members of The Knee Society were asked "Do you agree with the inclusion of this complication as among the minimum necessary for reporting outcomes of knee arthroplasty?" and "Do you agree with this definition?" RESULTS: One hundred two clinical members (100%) of The Knee Society responded to the survey. All proposed complications and definitions were endorsed by the members, and 678 suggestions were incorporated into the final work product. The 22 TKA complications and adverse events include bleeding, wound complication, thromboembolic disease, neural deficit, vascular injury, medial collateral ligament injury, instability, malalignment, stiffness, deep joint infection, fracture, extensor mechanism disruption, patellofemoral dislocation, tibiofemoral dislocation, bearing surface wear, osteolysis, implant loosening, implant fracture/tibial insert dissociation, reoperation, revision, readmission, and death. CONCLUSIONS: We identified 22 complications and adverse events that we believe are important for reporting outcomes of TKA. Acceptance and utilization of these standardized TKA complications may improve evaluation and reporting of TKA outcomes.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/efectos adversos , Prótesis de la Rodilla , Complicaciones Posoperatorias/clasificación , Falla de Prótesis , Humanos , Complicaciones Posoperatorias/etiología
15.
J Arthroplasty ; 28(8 Suppl): 120-1, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23886410

RESUMEN

Despite technical improvements, revision rates for total knee arthroplasties (TKAs) remain high. Our goal was to report the reason(s) for revision TKA in a large, current, multicenter series and compare those reasons with previously published reasons. We retrospectively identified 820 consecutive revision TKAs (693 patients, 2000-2012) from our 3 centers and recorded the primary reason for the revision. The top seven reasons for the revision were aseptic loosening (23.1%), infection (18.4%), polyethylene wear (18.1%), instability (17.7%), pain/stiffness (9.3%), osteolysis (4.5%), and malposition/malalignment (2.9%). Comparison with previously published reasons showed fewer TKA revisions for polyethylene wear, osteolysis, instability, and malalignment. These changes may represent improvements in surgical technique and implants.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/tendencias , Articulación de la Rodilla/cirugía , Prótesis de la Rodilla , Falla de Prótesis/etiología , Falla de Prótesis/tendencias , Adulto , Anciano , Anciano de 80 o más Años , Desviación Ósea/complicaciones , Desviación Ósea/epidemiología , Femenino , Humanos , Incidencia , Inestabilidad de la Articulación/complicaciones , Inestabilidad de la Articulación/epidemiología , Masculino , Persona de Mediana Edad , Osteólisis/complicaciones , Osteólisis/epidemiología , Falla de Prótesis/efectos adversos , Infecciones Relacionadas con Prótesis/complicaciones , Infecciones Relacionadas con Prótesis/epidemiología , Reoperación/tendencias , Estudios Retrospectivos
16.
J Arthroplasty ; 28(8): 1274-7, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23608085

RESUMEN

Pain control is necessary for successful rehabilitation and outcome after total knee arthroplasty. Our goal was to compare the clinical efficacy of periarticular injections consisting of a long-acting local anesthetic (ropivacaine) and epinephrine with and without combinations of an α2-adrenergic agonist (clonidine) and/or a nonsteroidal anti-inflammatory agent (ketorolac). In a double-blinded controlled study, we randomized 160 patients undergoing total knee arthroplasty to receive 1 of 4 intraoperative periarticular injections: Group A, ropivacaine, epinephrine, ketorolac, and clonidine; Group B, ropivacaine, epinephrine, and ketorolac; Group C, ropivacaine, epinephrine, and clonidine; Group D (control), ropivacaine and epinephrine. Compared with Group D, Group A and B patients had significantly lower postoperative visual analog pain scores and nurse pain assessment and Group C patients had a significantly greater reduction in physical therapist pain assessment. We found no differences in other parameters analyzed.


Asunto(s)
Analgésicos/administración & dosificación , Artroplastia de Reemplazo de Rodilla , Osteoartritis de la Rodilla/cirugía , Dolor Postoperatorio/prevención & control , Adulto , Anciano , Anciano de 80 o más Años , Amidas/administración & dosificación , Amidas/uso terapéutico , Analgésicos/uso terapéutico , Clonidina/administración & dosificación , Clonidina/uso terapéutico , Método Doble Ciego , Quimioterapia Combinada , Epinefrina/administración & dosificación , Epinefrina/uso terapéutico , Femenino , Humanos , Inyecciones Intraarticulares , Ketorolaco/administración & dosificación , Ketorolaco/uso terapéutico , Masculino , Persona de Mediana Edad , Dimensión del Dolor , Atención Perioperativa , Ropivacaína
17.
J Arthroplasty ; 28(7): 1231-4, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23643031

RESUMEN

In recent years, metal-on-metal (MOM) arthroplasty has come under fire with reported adverse outcomes of metal hypersensitivity, adverse local tissue reaction (ALTR), and the carcinogenicity concern from systemic metal ions. We present a retrospective analysis of 354 primary total hip arthroplasties from 2 independent centers. Revision data, predicted survival and Harris Hip Scores (HHS) are reported. Nine hips (2.5%) underwent component revision, and 9 year predicted survival was 95.8%. One revision had elevated metal ions but no histological evidence of ALTR. Average HHS at a minimum 5 year follow up (range 5-10 years) improved significantly from 52 pre-operatively to 93 post-operatively. While a 2.5% revision rate and improved clinical outcomes are reported in this study, longer term follow-up is warranted to monitor for late complications.


Asunto(s)
Artroplastia de Reemplazo de Cadera/instrumentación , Prótesis de Cadera , Metales , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Humanos , Iones , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/epidemiología , Diseño de Prótesis , Falla de Prótesis , Reoperación/estadística & datos numéricos , Estudios Retrospectivos , Análisis de Supervivencia , Resultado del Tratamiento
18.
J Knee Surg ; 26(2): 133-7, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23288757

RESUMEN

In middle-aged patients with knee arthritis, surgical treatment options include arthroscopic procedures, osteotomies, and unicompartmental and total knee arthroplasty. Unicompartmental knee osteoarthrosis is particularly challenging and controversial in such patients. From December 2001 through October 2005, we treated 32 consecutive middle-aged patients (46 to 59 years old) with 40 medial unicompartmental knee arthroplasties. Three patients were lost to follow-up, leaving 29 for our study. There were two reoperations: one for loosening at 3 years, and one for disease progression at 5 years. Implant survival was modeled using Kaplan-Meier survival function with observations censored if lost to follow-up. At the 6-year survivorship in this group, the overall implant survival rate was 94.1% (95% CI, 78.3-98.5). Knee Society scores had improved significantly (p < 0.001). There were no other instances of osteolysis or radiographic failure. We concluded that, at mid-term follow-up, unicompartmental knee arthroplasty provided satisfactory results for this challenging population.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla/cirugía , Factores de Edad , Estudios de Cohortes , Femenino , Humanos , Masculino , Persona de Mediana Edad , Osteoartritis de la Rodilla/diagnóstico , Osteoartritis de la Rodilla/etiología , Diseño de Prótesis , Falla de Prótesis , Rango del Movimiento Articular , Reoperación , Resultado del Tratamiento
19.
Clin Orthop Relat Res ; 470(1): 117-24, 2012 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-21739322

RESUMEN

BACKGROUND: In the United States, the obese population has increased markedly over the last four decades, and this trend continues. High patient weight places additional stress on TKA components, which may lead to increased polyethylene wear, osteolysis, radiolucencies, and clinical failure. Metal-backed tibial components and all-polyethylene tibial components in the general population have comparable osteolysis and failure, but it is unclear whether these components yield similar osteolysis and failure in obese patients. QUESTIONS/PURPOSES: We therefore determined the (1) function, (2) occurrence of osteolysis, and (3) complications in a cohort of obese patients receiving all-polyethylene tibial components. PATIENTS AND METHODS: Between September 17, 1996, and December 19, 2002, we implanted all-polyethylene tibial components in 90 obese patients (125 knees); 24 patients (33 knees) died and 13 patients (17 knees) were lost to followup, leaving 53 patients (59%) with 75 knees. All surgeries were cruciate-retaining, tricompartmental TKAs. We evaluated patients with Knee Society Scores and serial radiographs. Minimum followup was 7 years (mean, 10.4 years; range, 7-14 years). RESULTS: At latest followup, mean Knee Society Score was 92 points. There were five tibial radiolucencies, all less than 1 mm and characterized as nonprogressive. We observed minimal, nonprogressive osteolysis in one knee. One patient required reoperation after a traumatic event. There were no implant-related failures and no implants at risk of failure. CONCLUSIONS: At an average 10-year followup, all-polyethylene tibial components were functioning well in this obese group. These findings confirm the effectiveness of all-polyethylene tibial components in obese patients.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Prótesis de la Rodilla , Obesidad/diagnóstico , Polietileno/química , Diseño de Prótesis/métodos , Factores de Edad , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Rodilla/efectos adversos , Índice de Masa Corporal , Estudios de Cohortes , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Osteoartritis de la Rodilla/diagnóstico por imagen , Osteoartritis de la Rodilla/cirugía , Dolor Postoperatorio/fisiopatología , Falla de Prótesis , Radiografía , Rango del Movimiento Articular/fisiología , Recuperación de la Función , Estudios Retrospectivos , Medición de Riesgo , Factores Sexuales , Factores de Tiempo , Resultado del Tratamiento
20.
Instr Course Lect ; 61: 383-8, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22301246

RESUMEN

Pain management is a major concern for patients contemplating total knee replacement surgery and is one of the leading causes of dissatisfaction after knee replacement. Substantial progress has been made over the past several years in improving pain control after total knee replacement using multimodal pain control, preemptive analgesia, and periarticular injections.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Manejo del Dolor/métodos , Anestesia de Conducción , Celecoxib , Protocolos Clínicos , Inhibidores de la Ciclooxigenasa 2/administración & dosificación , Humanos , Cuidados Intraoperatorios , Bloqueo Nervioso , Dolor Postoperatorio/prevención & control , Pirazoles/administración & dosificación , Sulfonamidas/administración & dosificación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA