Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Radiology ; 286(1): 83-92, 2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-28813234

RESUMEN

Purpose To determine whether left atrial (LA) strain quantification with cardiac magnetic resonance (MR) imaging feature tracking is associated with the severity of LA fibrofatty myocardial remodeling at histologic analysis. Materials and Methods This prospective case-control study was approved by the institutional review board. LA strain was evaluated with cardiac MR feature tracking between January 2014 and March 2015 in 13 consecutive patients (mean age, 61 years ± 19; nine male) with mitral regurgitation in the 24 hours before mitral valve surgery and 13 age- and sex-matched healthy control subjects. LA strain parameters were compared first between control subjects and patients and then according to atrial fibrillation and mitral regurgitation status. Associations between LA strain and histology of preoperative biopsies were reported by using receiver operating characteristic curve analysis and Spearman correlation. Results Peak longitudinal atrial strain (PLAS) was significantly lower in patients with mitral regurgitation than in healthy control subjects (P < .001). Increased LA remodeling was significantly related to altered LA strain, and the strongest association was found between PLAS and the degree of fibrofatty myocardial replacement at histologic analysis (r = -0.75, P = .017). LA end-diastolic volume was increased in patients with mitral regurgitation when compared with that in healthy volunteers (P < .001) because of volume overload; however, volume did not correlate with the histologic degree of LA fibrofatty replacement (r = -0.35, P = .330). Conclusion LA strain, especially PLAS, correlates strongly with the degree of fibrofatty replacement at histologic analysis. Such functional imaging biomarker in combination with LA volumetry could help to guide clinical decisions, since myocardial structural remodeling is a known morphologic substrate of LA dysfunction leading to atrial fibrillation with adverse outcome. © RSNA, 2017 Online supplemental material is available for this article.


Asunto(s)
Tejido Adiposo/diagnóstico por imagen , Remodelación Atrial , Atrios Cardíacos/diagnóstico por imagen , Imagen por Resonancia Cinemagnética/métodos , Tejido Adiposo/patología , Adulto , Anciano , Anciano de 80 o más Años , Estudios de Casos y Controles , Femenino , Fibrosis/diagnóstico por imagen , Fibrosis/patología , Atrios Cardíacos/patología , Humanos , Masculino , Persona de Mediana Edad , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/patología , Estudios Prospectivos
2.
Am J Physiol Heart Circ Physiol ; 310(5): H542-9, 2016 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-26747498

RESUMEN

Importance of left atrial (LA) phasic function evaluation is increasingly recognized for its incremental value in terms of prognosis and risk stratification. LA phasic deformation in the pathway of normal aging has been characterized using echocardiographic speckle tracking. However, no data are available regarding age-related variations using feature-racking (FT) techniques from standard cine magnetic resonance imaging (MRI). We studied 94 healthy adults (41 ± 14 yr, 47 women), who underwent MRI and Doppler echocardiography on the same day for left ventricular (LV) diastolic function evaluation. From cine MRI, longitudinal strain and strain rate, radial motion fraction, and radial relative velocity, respectively, corresponding to the reservoir, conduit, and LA contraction phases, were measured using dedicated FT software. Longitudinal strain and radial motion fraction decreased gradually and significantly with aging for both reservoir (r > 0.31, P < 0.003) and conduit (r > 0.54, P < 0.001) phases, whereas they remained unchanged during the LA contraction phase. Subsequently, the LA contraction-to-reservoir ratio increased significantly with age (r > 0.44, P < 0.001). Longitudinal strain rate and radial relative velocity significantly decreased with age (reservoir: r = 0.39, P < 0.001, conduit: r > 0.54, P < 0.001), and these associations tended to be stronger in women than in men. Finally, associations of LA functional indexes with age were stronger in individuals with lower transmitral early-to-atrial maximal velocity ratio and mitral annulus maximal longitudinal velocity, as well as higher transmitral early maximal-to-mitral annulus maximal longitudinal velocity ratio, highlighting the LV-LA interplay. Age-related changes in LA phasic function indexes were quantified by cine MRI images using a FT technique and were significantly related to age and LV diastolic function.


Asunto(s)
Envejecimiento , Función del Atrio Izquierdo , Atrios Cardíacos/fisiopatología , Imagen por Resonancia Cinemagnética , Contracción Miocárdica , Adulto , Factores de Edad , Envejecimiento/patología , Fenómenos Biomecánicos , Ecocardiografía Doppler , Femenino , Voluntarios Sanos , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/patología , Humanos , Masculino , Persona de Mediana Edad , Factores Sexuales , Estrés Mecánico , Factores de Tiempo , Función Ventricular Izquierda , Adulto Joven
3.
J Magn Reson Imaging ; 42(2): 379-89, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25630749

RESUMEN

BACKGROUND: Left atrium (LA) volumes and function are predictors of cardiovascular events. Because LA function cannot be assessed from cardiovascular magnetic resonance imaging (MRI) using the well-established left ventricular tagging techniques, we hypothesized that adequate feature tracking (FT) applied to conventional cine MRI data could characterize LA function accurately. METHODS: We studied 10 young (28 ± 7 years) and 10 elderly (64 ± 6 years) healthy subjects, as well as 20 patients with moderate to severe aortic valve stenosis (AVS; 73 ± 15 years, effective aortic valve area: 0.67 ± 0.36 cm(2) ). MRI cine two-, three-, and four-chamber views were analyzed using a newly proposed FT method based on spatial correlation and endocardial detection resulting in: regional and global longitudinal strain and strain rate, radial motion fraction and relative velocity for the three LA motion phases including reservoir, conduit, and LA contraction. RESULTS: FT reliability was indicated by a good overlap between tracking results and manual LA endocardial borders, the low error for comparison against theoretical strains introduced in a synthetic phantom and the good inter-observer reproducibility (coefficient of variation < 15%). While all LA functional parameters were significantly impaired in AVS patients (p < 0.04), subclinical age-related variations induced a decreasing trend on all LA parameters but were significant only for radial conduit function parameters (p < 0.03). Finally, LA functional parameters characterized LA alteration in AVS with higher sensitivity than conventional LA volumetric parameters. CONCLUSIONS: Left atrial FT is feasible on MRI cine images and its addition to conventional analysis tools might enhance the diagnosis value of MRI in many heart diseases.


Asunto(s)
Algoritmos , Estenosis de la Válvula Aórtica/patología , Atrios Cardíacos/patología , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Cinemagnética/métodos , Reconocimiento de Normas Patrones Automatizadas/métodos , Anciano , Femenino , Humanos , Aumento de la Imagen/métodos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
4.
Eur Radiol ; 25(4): 1077-86, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25430004

RESUMEN

OBJECTIVES: Our objectives were to assess the ability of phasecontrast MRI (PC-MRI) to detect sub-clinical age-related variations of left ventricular (LV) diastolic parameters and thus to provide age-related reference ranges currently available for echocardiography but not for MRI-PC, and to identify independent associates of such variations. METHODS: We studied 100 healthy volunteers (age = 42 ± 15years, 50 females) who had MRI with simultaneous blood pressure measurements. LV mass and volumes were assessed. Semiautomated analysis of PC-MRI data provided: 1) early transmitral (Ef) and atrial (Af) peak filling flow-rates (ml/s) and filling volume (FV), 2) deceleration time (DT), isovolumic relaxation time (IVRT), and 3) early myocardial longitudinal (E') peak velocity. RESULTS: MRI-PC diastolic parameters were reproducible as reflected by low coefficients of variations (ranged between 0.31 to 6.26 %). Peak myocardial velocity E' (r = -0.63, p < 0.0001) and flow-rate parameters were strongly and independently associated to age (Ef/Af:r = -0.63, DT:r = 0.46, IVRT:r = 0.44, Ef/FV:r = -0.55, Af/FV:r = 0.56, p < 0.0001). Furthermore, LV relaxation parameters (E', DT, IVRT), were independently associated to LV remodelling (LV mass/end-diastolic volume) and myocardial wall thickness (p < 0.01). CONCLUSIONS: PC-MRI age-related reference ranges of diastolic parameters are provided. Such parameters might be useful for a fast, reproducible and reliable characterization of diastolic function in patients referred for clinical MRI exam KEY POINTS: • MRI age-related reference values of left ventricular diastolic parameters are provided. • MRI diastolic parameters can characterise sub-clinical age-related variations in healthy individuals. • Diastolic function would complement cardiac MRI exam with currently neglected data. • Diastolic function would enhance MRI diagnostic value in cardiomyopathy and heartfailure.


Asunto(s)
Envejecimiento/fisiología , Ventrículos Cardíacos/anatomía & histología , Imagen por Resonancia Cinemagnética/métodos , Función Ventricular Izquierda/fisiología , Adulto , Factores de Edad , Diástole , Femenino , Voluntarios Sanos , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven
5.
J Clin Microbiol ; 52(2): 688-91, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24478515
6.
J Cardiovasc Magn Reson ; 12: 63, 2010 Nov 09.
Artículo en Inglés | MEDLINE | ID: mdl-21062448

RESUMEN

BACKGROUND: Early detection of diastolic dysfunction is crucial for patients with incipient heart failure. Although this evaluation could be performed from phase-contrast (PC) cardiovascular magnetic resonance (CMR) data, its usefulness in clinical routine is not yet established, mainly because the interpretation of such data remains mostly based on manual post-processing. Accordingly, our goal was to develop a robust process to automatically estimate velocity and flow rate-related diastolic parameters from PC-CMR data and to test the consistency of these parameters against echocardiography as well as their ability to characterize left ventricular (LV) diastolic dysfunction. RESULTS: We studied 35 controls and 18 patients with severe aortic valve stenosis and preserved LV ejection fraction who had PC-CMR and Doppler echocardiography exams on the same day. PC-CMR mitral flow and myocardial velocity data were analyzed using custom software for semi-automated extraction of diastolic parameters. Inter-operator reproducibility of flow pattern segmentation and functional parameters was assessed on a sub-group of 30 subjects. The mean percentage of overlap between the transmitral flow segmentations performed by two independent operators was 99.7 ± 1.6%, resulting in a small variability (<1.96 ± 2.95%) in functional parameter measurement. For maximal myocardial longitudinal velocities, the inter-operator variability was 4.25 ± 5.89%. The MR diastolic parameters varied significantly in patients as opposed to controls (p < 0.0002). Both velocity and flow rate diastolic parameters were consistent with echocardiographic values (r > 0.71) and receiver operating characteristic (ROC) analysis revealed their ability to separate patients from controls, with sensitivity > 0.80, specificity > 0.80 and accuracy > 0.85. Slight superiority in terms of correlation with echocardiography (r = 0.81) and accuracy to detect LV abnormalities (sensitivity > 0.83, specificity > 0.91 and accuracy > 0.89) was found for the PC-CMR flow-rate related parameters. CONCLUSIONS: A fast and reproducible technique for flow and myocardial PC-CMR data analysis was successfully used on controls and patients to extract consistent velocity-related diastolic parameters, as well as flow rate-related parameters. This technique provides a valuable addition to established CMR tools in the evaluation and the management of patients with diastolic dysfunction.


Asunto(s)
Estenosis de la Válvula Aórtica/diagnóstico , Medios de Contraste , Ecocardiografía Doppler , Imagen por Resonancia Magnética , Imagen de Perfusión Miocárdica/métodos , Disfunción Ventricular Izquierda/diagnóstico , Función Ventricular Izquierda , Adulto , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/patología , Estenosis de la Válvula Aórtica/fisiopatología , Automatización de Laboratorios , Velocidad del Flujo Sanguíneo , Estudios de Casos y Controles , Circulación Coronaria , Diástole , Diagnóstico Precoz , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Paris , Valor Predictivo de las Pruebas , Curva ROC , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Índice de Severidad de la Enfermedad , Volumen Sistólico , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/patología , Disfunción Ventricular Izquierda/fisiopatología , Adulto Joven
7.
Arch Cardiovasc Dis ; 113(3): 168-175, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-32067947

RESUMEN

BACKGROUND: Standardization of aortic valve repair by the external ring annuloplasty approach is an alternative to valve replacement to avoid prosthetic valve-related events. Although the benefit of exercise training to improve postoperative exercise tolerance has been demonstrated in many conditions after cardiac surgery, it has never been described after aortic valve repair. OBJECTIVES: To evaluate the feasibility of an early exercise training programme after aortic valve repair. METHODS: Consecutive patients were prospectively included in 13 postoperative centres. Patients underwent an exercise training programme for approximately 3-5 weeks. Transthoracic echocardiography and a cardiopulmonary exercise test were performed before and after the exercise training programme. RESULTS: Fifty patients (mean±standard deviation [SD] age: 50±13 years) were included a mean of 13.6±12.0 days after aortic valve repair. The preoperative degree of aortic insufficiency was moderate to severe in 35 patients (70%) and the aortic valve was bicuspid in 24 patients (48%). Valve-sparing root replacement and isolated aortic valve repair (including 10% supracoronary aorta replacement) were performed in 64% and 36% of patients, respectively. We found no aortic insufficiency occurrence or worsening and no adverse clinical events after the exercise training programme. Mean left ventricular ejection fraction increased significantly (from 54%±8% to 57%±9%; P=0.0007). Mean peak oxygen consumption and first ventilatory threshold increased from 17.0±5.3 to 22.5±7.8mL/kg/min (32% increase) and from 12.0±3.9 to 14.3±5.2mL/kg/min (19% increase), respectively (both P<0.05). CONCLUSION: Exercise training early after aortic valve repair is safe and seems to significantly improve exercise capacity.


Asunto(s)
Válvula Aórtica/cirugía , Anuloplastia de la Válvula Cardíaca , Terapia por Ejercicio , Enfermedades de las Válvulas Cardíacas/cirugía , Implantación de Prótesis de Válvulas Cardíacas , Adulto , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Anuloplastia de la Válvula Cardíaca/efectos adversos , Anuloplastia de la Válvula Cardíaca/instrumentación , Terapia por Ejercicio/efectos adversos , Tolerancia al Ejercicio , Estudios de Factibilidad , Femenino , Francia , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/fisiopatología , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Recuperación de la Función , Sistema de Registros , Factores de Riesgo , Volumen Sistólico , Factores de Tiempo , Resultado del Tratamiento , Función Ventricular Izquierda
8.
PLoS One ; 13(10): e0205104, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30296279

RESUMEN

BACKGROUND: Atrial fibrillation is associated with an atrial cardiomyopathy composed mainly of fibrosis and adipose tissue accumulation. We hypothesized that MRI, when used in an optimal ex vivo setting allowing high spatial resolution without motion artifacts, can help characterizing the complex 3D left atrial (LA) wall composition in human myocardial samples, as compared to histology. METHODS: This prospective case-control study was approved by the institutional review board. 3D MRI acquisitions including saturation-recovery T1 mapping and DIXON imaging was performed at 4.0 T on 9 human LA samples collected from patients who underwent cardiac surgery. Histological quantification of fibrosis and fat was obtained. MRI T1 maps were clustered based on a Gaussian Mixture Model allowing quantification of total, interstitial and fatty fibrosis components. Fat maps were computed from DIXON images and fat fractions were calculated. MRI measurements were performed on the same location as the histological analysis (plane) and on the entire sample volume (3D). RESULTS: High correlations and levels of agreement were observed between MRI and histology for total (r = 0.93), interstitial (r = 0.93) and fatty fibrosis (r = 0.98) and fat (r = 0.96). Native T1 correlated with the amount of fibrosis from MRI and histology. The 3D MRI total, interstitial and fatty fibrosis ranges were between 6% and 23%, 4% and 17.3%; and 1.4% and 19.7% respectively. CONCLUSION: High Field ex vivo MRI was able to quantify different LA myocardial components with high agreement in 2D with histology and moreover to provide 3D quantification of such components whereas in vivo application remains a challenge.


Asunto(s)
Tejido Adiposo/diagnóstico por imagen , Fibrosis/diagnóstico por imagen , Atrios Cardíacos/diagnóstico por imagen , Cardiopatías/diagnóstico por imagen , Imagen por Resonancia Magnética , Miocardio/patología , Tejido Adiposo/patología , Estudios de Casos y Controles , Diagnóstico Diferencial , Fibrosis/patología , Cardiopatías/patología , Cardiopatías/cirugía , Humanos , Interpretación de Imagen Asistida por Computador , Imagenología Tridimensional , Estudios Prospectivos
9.
Circ Cardiovasc Imaging ; 5(5): 604-12, 2012 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-22798520

RESUMEN

BACKGROUND: Accurate quantification of aortic valve stenosis (AVS) is needed for relevant management decisions. However, transthoracic Doppler echocardiography (TTE) remains inconclusive in a significant number of patients. Previous studies demonstrated the usefulness of phase-contrast cardiovascular magnetic resonance (PC-CMR) in noninvasive AVS evaluation. We hypothesized that semiautomated analysis of aortic hemodynamics from PC-CMR might provide reproducible and accurate evaluation of aortic valve area (AVA), aortic velocities, and gradients in agreement with TTE. METHODS AND RESULTS: We studied 53 AVS patients (AVA(TTE)=0.87±0.44 cm(2)) and 21 controls (AVA(TTE)=2.96±0.59 cm(2)) who had TTE and PC-CMR of aortic valve and left ventricular outflow tract on the same day. PC-CMR data analysis included left ventricular outflow tract and aortic valve segmentation, and extraction of velocities, gradients, and flow rates. Three AVA measures were performed: AVA(CMR1) based on Hakki formula, AVA(CMR2) based on continuity equation, AVA(CMR3) simplified continuity equation=left ventricular outflow tract peak flow rate/aortic peak velocity. Our analysis was reproducible, as reflected by low interoperator variability (<4.56±4.40%). Comparison of PC-CMR and TTE aortic peak velocities and mean gradients resulted in good agreement (r=0.92 with mean bias=-29±62 cm/s and r=0.86 with mean bias=-12±15 mm Hg, respectively). Although good agreement was found between TTE and continuity equation-based CMR-AVA (r>0.94 and mean bias=-0.01±0.38 cm(2) for AVA(CMR2), -0.09±0.28 cm(2) for AVA(CMR3)), AVA(CMR1) values were lower than AVA(TTE) especially for higher AVA (mean bias=-0.45±0.52 cm(2)). Besides, ability of PC-CMR to detect severe AVS, defined by TTE, provided the best results for continuity equation-based methods (accuracy >94%). CONCLUSIONS: Our PC-CMR semiautomated AVS evaluation provided reproducible measurements that accurately detected severe AVS and were in good agreement with TTE.


Asunto(s)
Estenosis de la Válvula Aórtica/diagnóstico , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Ecocardiografía Doppler , Hemodinámica , Imagen por Resonancia Cinemagnética , Adulto , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Automatización de Laboratorios , Velocidad del Flujo Sanguíneo , Estudios de Casos y Controles , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Paris , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Índice de Severidad de la Enfermedad , Función Ventricular Izquierda , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA