RESUMEN
BACKGROUND: Despite continuous improvements in transcatheter aortic valve implantation (TAVI), periprocedural strokes remain a devastating complication. Randomized controlled trials failed to demonstrate a reduction in clinically apparent strokes or mortality after TAVI due to cerebral embolic protection (CEP). To identify potential targets of CEP strategies during TAVI, we evaluated affected brain regions, and temporal patterns of stroke onset in a routine clinical sample. METHODS AND RESULTS: A total of 3,164 consecutive patients treated with TAVI from 2008 to 2019 at a single center were screened for cerebrovascular events. Affected cerebral regions were determined according to clinical symptoms and brain imaging. Rates of disabling stroke and non-disabling stroke at 30 days were 2.2% and 1.4%, respectively. The frequency of all strokes decreased from 5.0% to 3.0% over time (P = .012). Patients with impaired left-ventricular function (OR 2.19), increased CHA2DS2-VASc (OR 1.39) and moderate/severe spontaneous echo contrast (OR 3.60) had a higher stroke risk. Acute symptom onset occurred during TAVI (19.4%), within 24 hours (40.3%) or later (25.0%); 98.3% of strokes were of ischemic origin. In intraprocedural strokes, 53.2% of lesions were found in locations considered protected by current CEP devices, and 37.5% of patients with intraprocedural strokes were exclusively affected in these areas. Baseline or procedural parameters were not associated with embolic distribution patterns. CONCLUSIONS: Most strokes occurred early after TAVI - but not necessarily during the procedure - and affected multiple brain regions only partially protected by current CEP devices. Efficient prevention of cerebrovascular events may require strategies beyond the TAVI procedure to minimize stroke risk and additional randomized controlled trials will be required to clarify the role of CEP in efficient stroke prevention during TAVI.
Asunto(s)
Estenosis de la Válvula Aórtica , Dispositivos de Protección Embólica , Implantación de Prótesis de Válvulas Cardíacas , Embolia Intracraneal , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Encéfalo/diagnóstico por imagen , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Embolia Intracraneal/epidemiología , Embolia Intracraneal/etiología , Embolia Intracraneal/prevención & control , Factores de Riesgo , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del TratamientoRESUMEN
BACKGROUND: Previous reports suggest septal hypertrophy with an interventricular septum depth (IVSD) ≥ 14 mm may adversely affect outcomes after transcatheter aortic valve implantation (TAVI) due to suboptimal valve placement, valve migration, or residual increased LVOT pressure gradients. AIMS: This analysis investigates the impact of interventricular septal hypertrophy on acute outcomes after TAVI. METHODS: Between 2009 and 2021, 1033 consecutive patients (55.8% male, 80.5 ± 6.7 years, EuroSCORE II 6.3 ± 6.5%) with documented IVSD underwent TAVI at our center and were included for analysis. Baseline, periprocedural, and 30-day outcome parameters of patients with normal IVSD (< 14 mm; group 1) and increased IVSD (≥ 14 mm; group 2) were compared. Data were retrospectively analyzed according to updated Valve Academic Research Consortium-3 (VARC-3) definitions. Comparison of outcome parameters was adjusted for baseline differences between groups using logistic and linear regression analyses. RESULTS: Of 1033 patients, 585 and 448 patients were allocated to groups 1 and 2, respectively. There was no significant difference between groups regarding transfemoral access rate (82.6% (n = 478) vs. 86.0% (n = 381), p = 0.157). Postprocedural mean transvalvular pressure gradient was significantly increased in group 2 (group 1, 7.8 ± 4.1 mmHg, vs. group 2, 8.9 ± 4.9 mmHg, p = 0.046). Despite this finding, there was no significant difference between groups regarding the rates of VARC-3 adjudicated composite endpoint device success (90.0% (n = 522) vs. 87.6% (n = 388), p = 0.538) or technical success (92.6% (n = 542) vs. 92.6% (n = 415), p = 0.639). Moreover, the groups showed no significant differences regarding the rates of paravalvular leakage ≥ moderate (3.1% (n = 14) vs. 2.6% (n = 9), p = 0.993), postprocedural permanent pacemaker implantation (13.4% (n = 77) vs. 13.8% (n = 61), p = 0.778), or 30-day mortality (5.1% (n = 30) vs. 4.5% (n = 20), p = 0.758). CONCLUSION: Although transvalvular mean pressure gradients were significantly higher in patients with increased IVSD after TAVI, acute outcomes were comparable between groups suggesting no early impact of adverse hemodynamics due to elevated IVSD. However, how these differences in hemodynamic findings may affect mid- and long-term outcomes, especially in terms of valve durability, needs to be evaluated in further investigations.
RESUMEN
BACKGROUND: Marfan syndrome (MFS) guidelines recommend optimal pharmacologic therapy (OPT) and replacement of the ascending aorta (RAA) at 5.0 cm in diameter to prevent acute type A aortic dissection (ATAAD) and death. The effect of early MFS diagnosis and initiation of therapy on outcomes is not known. Therefore, we sought to evaluate the effect of age at MFS diagnosis and therapy initiation on delayed RAA and death. METHODS: This retrospective observational cohort study with long-term follow-up included consecutive patients with MFS, pathogenic FBN1 variant, and regular visits to a European Reference Network Center. We considered MFS diagnosis at age ≥21 years late and OPT initiation at age <21 years early. Outcomes were delayed RAA with aneurysm diameter >5.0 cm or ATAAD and death from all causes. We used landmark design starting at age 21 years to determine associations with outcomes. RESULTS: The study group consisted of 288 patients (45.1% male), including 169 patients with late diagnosis of MFS (58.7%) and 63 with early OPT (21.9%). During mean follow-up of 25 ± 14.7 years, 78 patients had delayed RAA, with 42 operations for ATAAD and 36 for aneurysms ≥5.0 cm. There were 33 deaths, including 11 deaths late after ATAAD. All deaths were cardiovascular. Late diagnosis, but not early OPT, showed univariate association with delayed RAA (P < .001) and death (P = .025). Multivariate Cox regression analysis confirmed late diagnosis as predictor of delayed RAA (hazard ratio, 8.01; 95% confidence interval, 2.52-25.45; P < .001) and death (hazard ratio, 4.68; 95% confidence interval, 1.17-18.80; P = .029). CONCLUSIONS: Late diagnosis of MFS is associated with delayed surgery and death.
RESUMEN
Background and Objective: Since 2003, the Frozen Elephant Trunk (FET) technique has attained rising popularity for treating extensive aortic arch pathologies such as acute and chronic aortic dissection, as well as thoracic aortic aneurysm. Conventionally, the FET procedure included a complete resection of the aortic arch and, subsequently, a distal aortic anastomosis of the prosthetic part of the hybrid graft in arch zone 3. Simultaneous to the introduction of the FET technique, the traditional Elephant Trunk technique was simplified by adding debranching techniques which allows for proximalization of the distal aortic anastomosis. Nowadays, modern concepts of aortic arch surgery combine the FET technique with proximalization of the distal anastomosis in arch zone 2 or further proximal, achieved by using different debranching techniques. This review describes different debranching techniques to facilitate arch reconstruction, and aims to critically assess the outcomes and potential clinical advantages of proximalization using debranching in FET surgery. Methods: We conducted a search using the PubMed and Google Scholar electronic databases to evaluate published outcomes of different debranching techniques. An overview of the data synthesis of 21 included studies is reported. Key Content and Findings: Most studies report numeric, but not statistically significant improved outcomes after debranching in FET surgery for mortality, neurological complications, spinal cord injury, kidney failure, bowel ischemia and recurrent nerve palsy. Some studies report statistically significant improved results in isolated endpoints such as neurological, bowel ischemia, and recurrent nerve palsy. Most studies report debranching to be technically easier, but this is difficult to objectively assess and measure. Conclusions: There is an improved numeric outcome of different debranching techniques with proximalization of the distal anastomosis, but without reaching statistical significance. This review shows marked heterogeneity across included studies and highlights the scarce use of existing guidelines in clinical research of open aortic arch surgery as proposed by the International Aortic Arch Surgery Study Group. Furthermore, this review demonstrates the urgent need for multicenter registries or studies to be able to compare the outcome of different surgical techniques for various aortic arch pathologies.
RESUMEN
BACKGROUND: Beneficial results of transcatheter aortic valve implantation (TAVI) compared to surgical aortic valve replacement (SAVR) in patients at all risk strata have led to substantial changes in guideline recommendations for valvular heart disease. AIM: To examine influence of these guideline changes on a real-world TAVI cohort, we evaluated how risk profiles and outcomes of TAVI patients developed in our single-center patient cohort over a period of 12 years. METHODS: Baseline, procedural and 30-day outcome parameters of TAVI patients were retrospectively compared between three time periods (period 1: 2008-2012, period 2: 2013-2017, period 3: 2018-2020). RESULTS: Between 03/2008 and 12/2020, a total of 3678 patients underwent TAVI at our center. The median age was 81.1 years (25th, 75th percentile: 76.7, 84.9) with no significant change over time. The EuroSCORE II showed a continuous and significant decline from 5.3% (3.3, 8.6) in period 1 to 2.8% (1.7, 5.0) in period 3 (p < 0.001). Furthermore, rates of permanent pacemaker implantation, acute kidney injury, and paravalvular leakage ≥ moderate continuously declined over time. Accordingly, the 30-day mortality fell from 9.3% in period 1 to 4.3% in period 3 (p < 0.001). CONCLUSION: Despite substantial guideline alterations, median patient age remained largely unchanged in our TAVI cohort over the past 12 years. Therefore, increased age still appears to be the main reason to choose TAVI over SAVR. However, risk profiles declined substantially. Significant improvements in early outcomes suggest favorable influence of less invasive access routes, improved device platforms and growing user experience.
Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Anciano de 80 o más Años , Niño , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodosRESUMEN
Background: Valve-in-valve (ViV) transfemoral transcatheter aortic valve implantation (TAVI) for failing aortic surgical bioprostheses or transcatheter heart valves (THV) has demonstrated a reasonable clinical and hemodynamic efficacy. Traditionally, self-expanding (SE) supra-annular THV are considered to result in superior hemodynamics compared with balloon-expandable intra-annular THV after ViV. However, so far no data are found on latest-generation intra-annular SE THV for aortic ViV procedures which might be superior with regard to coronary access or subsequent valve reintervention. Aim: We herein aim to evaluate a latest-generation SE intra-annular THV for aortic ViV procedures. Materials and methods: Between May 2022 and November 2022, five consecutive patients (4/5 female with mean age of 76.2 years and mean Society of Thoracic Surgeons predicted risk of mortality score of 2.9%) received ViV TAVI using the Navitor system (Abbott, Chicago, IL, USA) for treatment of failing surgical bioprostheses or THV. Data were retrospectively analyzed according to updated Valve Academic Research Consortium 3 (VARC-3) definitions. Results: At 30 days, absence of mortality and VARC-3 adjudicated clinical endpoints were documented. Echocardiography at 30 days revealed complete absence of paravalvular leakage and single-digit mean transvalvular gradients (mean of 6.0â mmHg) in all patients. Conclusion: The investigated intra-annular SE THV results in excellent 30-day outcomes for aortic ViV procedures for failing surgical bioprostheses or THV. Despite the intra-annular design, hemodynamic results were excellent, even in small bioprostheses. Ease of use of this valve platform is reflected by only two cycles of resheathing in five ViV procedures with hemodynamic stability during all steps of valve deployment.
RESUMEN
MASS phenotype is a connective tissue disorder clinically overlapping with Marfan syndrome and caused by pathogenic variants in FBN1. We report four patients from three families presenting with a MASS-like phenotype consisting of tall stature, arachnodactyly, spinal deformations, dural ectasia, pectus and/or feet deformations, osteoarthritis, and/or high arched palate. Gene panel sequencing was negative for FBN1 variants. However, it revealed likely pathogenic missense variants in three individuals [c.3936G > T p.(Lys1312Asn), c.193G > A p.(Asp65Asn)] and a missense variant of unknown significance in the fourth patient [c.4013G > A p.(Ser1338Asn)] in propeptide coding regions of COL2A1. Pathogenic COL2A1 variants are associated with type II collagenopathies comprising a remarkable clinical variablility. Main features include skeletal dysplasia, ocular anomalies, and auditory defects. A MASS-like phenotype has not been associated with COL2A1 variants before. Thus, the identification of likely pathogenic COL2A1 variants in our patients expands the phenotypic spectrum of type II collagenopathies and suggests that a MASS-like phenotype can be assigned to various hereditary disorders of connective tissue. We compare the phenotypes of our patients with related disorders of connective tissue and discuss possible pathomechanisms and genotype-phenotype correlations for the identified COL2A1 variants. Our data recommend COL2A1 sequencing in FBN1-negative patients suggestive for MASS/Marfan-like phenotype (without aortopathy).
Asunto(s)
Síndrome de Marfan , Colágeno Tipo II/genética , Genotipo , Humanos , Síndrome de Marfan/diagnóstico , Síndrome de Marfan/genética , Prolapso de la Válvula Mitral , Mutación , Miopía , Fenotipo , Enfermedades de la PielRESUMEN
OBJECTIVES: The goal of this study was to determine the outcome of patients undergoing an elective frozen elephant trunk (FET) procedure as a redo operation following previous cardiac surgery. METHODS: One hundred and eighteen consecutive patients underwent FET procedures between October 2010 and October 2019 at our centre. Patients were registered in a dedicated database and analysed retrospectively. Clinical and follow-up characteristics were compared between patients undergoing a FET operation as a primary (primary group) or a redo procedure (redo group) using logistic regression and Cox regression analysis. Emergency procedures (n = 33) were excluded from the analysis. RESULTS: A total of 36.5% (n = 31) of the FET procedures were redo operations (redo group) and 63.5% (n = 54) of the patients underwent primary surgery (primary group). There was no significant difference in the 30-day mortality [primary group: 7.4%; redo group: 3.2%; 95% confidence interval (CI) (0.19-35.29); P = 0.63] and the 3-year mortality [primary group: 22.2%; redo group: 16.7%; 95% CI (0.23-3.23); P = 0.72] between redo and primary cases. Furthermore, the adjusted statistical analysis did not reveal significant differences between the groups in the occurrence of transient or permanent neurological deficit, paraplegia, acute renal failure and resternotomy. The redo group showed a higher rate of recurrent nerve palsy, which did not reach statistical significance [primary group: 3.7% (n = 2); redo group: 19.4% (n = 6); P = 0.091]. CONCLUSIONS: Elective FET procedures as redo operations performed by a dedicated aortic team following previous cardiac surgery demonstrate an adequate safety profile.
Asunto(s)
Aneurisma de la Aorta Torácica , Implantación de Prótesis Vascular , Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/cirugía , Implantación de Prótesis Vascular/efectos adversos , Humanos , Paraplejía , Estudios Retrospectivos , Resultado del TratamientoRESUMEN
BACKGROUND: The number of patients requiring lead extraction has been increasing in recent years. Despite significant advances in operator experience and technique, unexpected complications may occur. Prophylactic placement of femoral sheaths allows for immediate endovascular access for emergency procedures and may shorten response time in the event of complications. OBJECTIVE: The purpose of this study was to assess the benefits of routine prophylactic femoral access in patients undergoing transvenous lead extraction (TLE) and to evaluate the methods, frequency, and efficacy of the emergency measures used in those patients. METHODS: We conducted a retrospective analysis of patients who underwent TLE from January 2012 to February 2019. The data were analyzed with regard to procedural complications and deployment of emergency measures via femoral access. RESULTS: Two hundred eighty-five patients (mean age 65.3 ± 15.5 years) were included in the study. Median lead dwell time was 84 months (interquartile range 58-144). Overall complication rate was 4.2% (n = 12), with 1.8% major complications (n = 5). Clinical success rate was 97.2%. Procedure-related mortality was 1.1% (n = 3). Femoral sheaths were actively engaged in 9.1% (n = 26) of cases. Deployment of snares was the most common intervention (n = 10), followed by prophylactic (n = 6) or emergency placement (n = 1) of occlusion balloons, temporary pacing (n = 3), venous angioplasty (n = 3), diagnostic venography (n = 3), and extracorporeal membrane oxygenation (n = 1). We did not observe any femoral vascular complications due to prophylactic sheath placement. CONCLUSION: Routine prophylactic placement of femoral sheaths shortens response time and quickly establishes control in the event of various complications that may occur during TLE procedures.
Asunto(s)
Desfibriladores Implantables , Remoción de Dispositivos/efectos adversos , Marcapaso Artificial , Complicaciones Posoperatorias/prevención & control , Anciano , Femenino , Vena Femoral , Estudios de Seguimiento , Humanos , Masculino , Estudios Retrospectivos , Factores de Riesgo , Resultado del TratamientoRESUMEN
OBJECTIVES: This study aims to analyse the impact of a simplified frozen elephant trunk (FET) technique on early outcome. METHODS: Between October 2010 and August 2018, 92 consecutive patients (mean age 64.4 ± 12.2 years) underwent FET surgery. Underlying pathologies were thoracic aneurysm in 35 patients, acute aortic dissection in 25 patients and chronic dissection in 32 patients. Thirty patients underwent a simplified FET technique with deployment of the stent graft in arch zone 2 with an extra-anatomic bypass to the distal left subclavian artery using the third branch of the Thoraflex™ Hybrid Plexus prosthesis via a supraclavicular access during reperfusion. These patients were compared to 62 patients who received the conventional FET procedure, in which a distal anastomosis is performed in arch zone 3. RESULTS: Circulatory arrest (41.7 ± 10.5 vs 76.5 ± 33.0 min; P < 0.001) and antegrade cerebral perfusion times (60.9 ± 13.5 vs 92.1 ± 33.1 min; P < 0.001) were significantly reduced in zone 2 vs zone 3 patients, respectively. The 30-day mortality rate was 3.3% (n = 1) in zone 2 patients vs 17.7% (n = 11) in zone 3 patients (P = 0.75). Stent deployment in zone 2 was associated with significantly reduced rates of postoperative stroke [zone 2: n = 0 (0.0%); zone 3: n = 11 (17.7%), P = 0.046] and recurrent nerve palsy [zone 2: n = 1 (3.3%); zone 3: n = 14 (22.6%), P = 0.020). CONCLUSIONS: Simplifying the FET procedure leads to reduced circulatory arrest and cerebral perfusion times and improves early outcome.
Asunto(s)
Aneurisma de la Aorta Torácica/cirugía , Disección Aórtica/cirugía , Implantación de Prótesis Vascular/métodos , Stents , Enfermedad Aguda , Anciano , Terapia Combinada , Procedimientos Endovasculares , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Tiempo , Resultado del TratamientoRESUMEN
The genetics of many congenital heart diseases (CHDs) can only unsatisfactorily be explained by known chromosomal or Mendelian syndromes. Here, we present sequencing data of a family with a potentially multigenic origin of CHD. Twelve of nineteen family members carry a familial mutation [NM_004329.2:c.1328 G > A (p.R443H)] which encodes a predicted deleterious variant of BMPR1A. This mutation co-segregates with a linkage region on chromosome 1 that associates with the emergence of severe CHDs including Ebstein's anomaly, atrioventricular septal defect, and others. We show that the continuous overexpression of the zebrafish homologous mutation bmpr1aap.R438H within endocardium causes a reduced AV valve area, a downregulation of Wnt/ß-catenin signalling at the AV canal, and growth of additional tissue mass in adult zebrafish hearts. This finding opens the possibility of testing genetic interactions between BMPR1A and other candidate genes within linkage region 1 which may provide a first step towards unravelling more complex genetic patterns in cardiovascular disease aetiology.