Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Eur Radiol ; 2023 Nov 11.
Artículo en Inglés | MEDLINE | ID: mdl-37951854

RESUMEN

OBJECTIVES: To systematically investigate and summarize the utility of coronary computed tomographic angiography (CCTA) in the management of chronic total occlusion (CTO)-percutaneous coronary intervention (PCI). METHODS: The authors searched the four databases between 2005 and 2023 for studies investigating the role of CCTA and invasive coronary angiograms (ICA) images when used as the pre-procedural tool for CTO-PCI. Efficacy and safety of CCTA in CTO-PCI treatment as a pre-procedural assessment tool was evaluated. RESULTS: Forty-seven studies were finally chosen for this systematic review. CCTA had a high degree of agreement with ICA when applied for J-CTO scoring system. A J-CTO (Multicenter CTO Registry in Japan) score > 3, together with calcification, occlusion length ≥ 20 mm, blunt stump, and bending > 45° were shared imaging risk factors on both ICA and CCTA for technique failure and guidewire crossing over 30 min. Additionally, negative remodeling and multiple diseased vessel were significant indicators on CCTA. Although patients with pre-procedural CCTA showed a trend of higher success rate and easier guidewire crossing, and CCTA showed a slightly higher predictive accuracy for process success, no significant improvement in post-PCI major adverse cardiac events of using CCTA for assessment has been achieved. CONCLUSIONS: CCTA is a safe and effective pre-operative tool of CTO-PCI. Except for the shared imaging risk factors with ICA for a hard CTO-PCI including calcification, occlusion length ≥ 20 mm, blunt stump, bending > 45°, and J-CTO score > 3, factors like negative remodeling and multiple diseased vessel were also recognized as significant pre-operative assessment indicators on CCTA. CLINICAL RELEVANCE STATEMENT: A pre-procedural assessment based on coronary computed tomographic angiography has the potential to aid in the management of chronic total occlusion percutaneous coronary intervention. KEY POINTS: • A coronary computed tomographic angiography-based pre-procedural assessment can help chronic total occlusion-percutaneous coronary intervention management. • The recognized high-risk features detected via coronary computed tomographic angiography and invasive coronary angiograms are comparable in detecting difficult lesions and chronic total occlusion-percutaneous coronary intervention failure. • Coronary computed tomographic angiography has an additional value to be a safe and effective pre-procedural assessment tool for chronic total occlusion-percutaneous coronary intervention.

2.
Eur Radiol ; 32(5): 2912-2920, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35059803

RESUMEN

OBJECTIVES: To explore the use of 70-kVp tube voltage combined with high-strength deep learning image reconstruction (DLIR-H) in reducing radiation and contrast doses in coronary CT angiography (CCTA) in patients with body mass index (BMI) < 26 kg/m2, in comparison with the conventional scan protocol using 120 kVp and adaptive statistical iterative reconstruction (ASIR-V). METHODS: A total of 100 patients referred to CCTA were prospectively enrolled and randomly divided into two groups: low-dose group (n = 50) with 70 kVp, Smart mA for noise index (NI) of 36HU, contrast dose rate of 16mgI/kg/s, and DLIR-H, and conventional group (n = 50) with 120 kV, Smart mA for NI of 25HU, contrast dose rate of 32mgI/kg/s, and 60%ASIR-V. Radiation and contrast dose, subjective image quality score, and objective image quality measurement (image noise, contrast-noise-ratio (CNR), and signal-noise-ratio (SNR) for vessel) were compared between the two groups. RESULTS: Low-dose group used significantly reduced contrast dose (23.82 ± 3.69 mL, 50.6% reduction) and radiation dose (0.75 ± 0.14 mSv, 54.5% reduction) compared to the conventional group (48.23 ± 6.38 mL and 1.65 ± 0.66 mSv, respectively) (all p < 0.001). Both groups had similar enhancement in vessels. However, the low-dose group had lower background noise (23.57 ± 4.74 HU vs. 35.04 ± 8.41 HU), higher CNR in RCA (48.63 ± 10.76 vs. 29.32 ± 5.52), LAD (47.33 ± 10.20 vs. 29.27 ± 5.12), and LCX (46.74 ± 9.76 vs. 28.58 ± 5.12) (all p < 0.001) compared to the conventional group. CONCLUSIONS: The use of 70-kVp tube voltage combined with DLIR-H for CCTA in normal size patients significantly reduces radiation dose and contrast dose while further improving image quality compared with the conventional 120-kVp tube voltage with 60%ASIR-V. KEY POINTS: • The combination of 70-kVp tube voltage and high-strength deep learning image reconstruction (DLIR-H) algorithm protocol reduces approximately 50% of radiation and contrast doses in coronary computed tomography angiography (CCTA) compared with the conventional scan protocol. • CCTA of normal size (BMI < 26 kg/m2) patients acquired at sub-mSv radiation dose and 24 mL contrast dose through the combination of 70-kVp tube voltage and DLIR-H algorithm achieves excellent diagnostic image quality with a good inter-rater agreement. • DLIR-H algorithm shows a higher capacity of significantly reducing image noise than adaptive statistical iterative reconstruction algorithm in CCTA examination.


Asunto(s)
Angiografía por Tomografía Computarizada , Aprendizaje Profundo , Algoritmos , Angiografía por Tomografía Computarizada/métodos , Medios de Contraste , Angiografía Coronaria/métodos , Humanos , Procesamiento de Imagen Asistido por Computador , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador/métodos
3.
BMC Cardiovasc Disord ; 22(1): 30, 2022 02 04.
Artículo en Inglés | MEDLINE | ID: mdl-35120436

RESUMEN

BACKGROUND: Primary percutaneous coronary intervention (PPCI) is the standard procedure for reperfusion for ST-segment elevation myocardial infarction (STEMI), but the occurrence of the no-reflow phenomenon remains common and is associated with adverse outcomes. AIMS: This study aimed to evaluate whether prolonged balloon inflation in stent deployment would lessen the occurrence of the no-reflow phenomenon in PPCI compared with conventional rapid inflation/deflation strategy. METHODS: Patients were randomly assigned to either the prolonged balloon inflation in stent deployment group (PBSG) or conventional deployment strategy group (CDSG) in a 1:1 ratio. A subset of patients was included in the cardiac magnetic resonance (CMR) assessment. RESULTS: Thrombolysis in MI (TIMI) flow grade 3 was found in 96.7% and 63.3% of the patients of the PBSG and CDSG, respectively (P = 0.005). The results of the PBSG and CDSG are respectively shown as follows: 0% versus 30% no-reflow or slow flow (P = 0.002); 90% versus 66.7% ST-segment resolution ≥ 50% (P = 0.028); 35.6 ± 14.5 frames versus 49.18 ± 25.2 frames on corrected TIMI frame count (P = 0.014); and 60% versus 20% myocardial blush grade 3 (P = 0.001). At 1 month, the major cardiovascular adverse event (cardiovascular mortality) rate was 3.3% in both groups; at 1 year, the rate was 3.3% and 6.7% for the PBSG and CDSG, respectively (P = 1.00). In the CMR subset of cases, the presence of microvascular obstruction (MVO) was detected in 6.7% and 50% of the patients in the PBSG and CDSG, respectively (P = 0.023). CONCLUSION: In our pilot trial, prolonged balloon inflation during stent deployment strategy in PPCI reduces the occurrence of the no-reflow phenomenon in patients with STEMI and improved the myocardial microcirculation perfusion (ClinicalTrials.gov number: NCT03199014; registered: 26/June/2017).


Asunto(s)
Circulación Coronaria/fisiología , Electrocardiografía/métodos , Complicaciones Intraoperatorias , Fenómeno de no Reflujo/etiología , Intervención Coronaria Percutánea/efectos adversos , Infarto del Miocardio con Elevación del ST/cirugía , Stents/efectos adversos , Angiografía Coronaria , Femenino , Estudios de Seguimiento , Humanos , Masculino , Microcirculación/fisiología , Persona de Mediana Edad , Fenómeno de no Reflujo/diagnóstico , Proyectos Piloto , Infarto del Miocardio con Elevación del ST/diagnóstico , Método Simple Ciego , Factores de Tiempo , Resultado del Tratamiento
4.
Sichuan Da Xue Xue Bao Yi Xue Ban ; 53(3): 497-503, 2022 May.
Artículo en Zh | MEDLINE | ID: mdl-35642161

RESUMEN

Objective: To explore the feasibility of single-breath-hold compressed sensing real-time cine imaging (CS-cine) in the assessment of ventricular function and left ventricular (LV) strain. Methods: A total of 70 subjects were enrolled prospectively, and all subjects underwent cardiac magnetic resonance imaging (cardiac MRI) using both the standard steady-state free procession cine (sta-cine) acquisition and a prototype CS-cine sequence. For both CS-cine and sta-cine imaging, continuous short-axis cine images were acquired from the base to the apex to cover the entire left ventricle, and long-axis cine images including two-, three-, and four-chamber views were also acquired. The scanning range, number of slices, slice thickness and intervals were kept identical for the two cine images of the same participant. Subjective evaluation of the image quality was performed on all cine images. For both sequences, the conventional function parameters of the left and the right ventricles and LV strain values were assessed with post-processing software analysis. The cine image quality, conventional ventricular function parameters, and LV strain values were compared between the two cine groups and the differences were examined. Inter- and intraobserver agreements for CS-cine images were measured using intraclass correlation coefficient ( ICC). Bland-Altman analysis was performed to assess reproducibility between the two cine methods. Results: The median scanning time of CS-cine was 21 s versus 272 s for sta-cine ( P<0.001). The median image quality scores of two groups were significantly different, 4 points for sta-cine and 2 points for CS-cine ( P<0.001). Bi-ventricular end-diastolic volumes (EDV), stroke volume (SV) and ejection fraction (EF) were significantly smaller in CS-cine ( P<0.001). Nevertheless, no significant differences between the two groups in bi-ventricular ESV or LV mass were observed ( P>0.05). LV strain parameters, including the peak radial strain, peak circumferential strain and peak longitudinal strain derived from LV mid-ventricular slice, were significantly different in the two sequences ( P<0.001). Moreover, CS-cine-derived functional parameters and strain measurements have a good correlation with those of sta-cine (for RV function parameters, and left ventricular PLS, PCS values, more than 95% points fell within the limits of agreement [ LoA]; meanwhile, more than 91% points fell within the LoA for other parameters) and inter- and intraobserver agreements were strong ( ICC=0.88 to 0.99) for CS-cine. Conclusion: CS-cine can well realize the rapid acquisition of cine images for quantitative analysis of cardiac function, and the conventional ventricular function parameters and LV globalized strain values obtained from CS-cine imaging have good reproducibility.


Asunto(s)
Ventrículos Cardíacos , Imagen por Resonancia Cinemagnética , Estudios de Factibilidad , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética , Imagen por Resonancia Cinemagnética/métodos , Espectroscopía de Resonancia Magnética , Reproducibilidad de los Resultados , Función Ventricular Izquierda
5.
Radiology ; 295(3): 200463, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32077789

RESUMEN

In this retrospective study, chest CTs of 121 symptomatic patients infected with coronavirus disease-19 (COVID-19) from four centers in China from January 18, 2020 to February 2, 2020 were reviewed for common CT findings in relationship to the time between symptom onset and the initial CT scan (i.e. early, 0-2 days (36 patients), intermediate 3-5 days (33 patients), late 6-12 days (25 patients)). The hallmarks of COVID-19 infection on imaging were bilateral and peripheral ground-glass and consolidative pulmonary opacities. Notably, 20/36 (56%) of early patients had a normal CT. With a longer time after the onset of symptoms, CT findings were more frequent, including consolidation, bilateral and peripheral disease, greater total lung involvement, linear opacities, "crazy-paving" pattern and the "reverse halo" sign. Bilateral lung involvement was observed in 10/36 early patients (28%), 25/33 intermediate patients (76%), and 22/25 late patients (88%).


Asunto(s)
Infecciones por Coronavirus/diagnóstico por imagen , Enfermedades Pulmonares/diagnóstico por imagen , Enfermedades Pulmonares/virología , Neumonía Viral/diagnóstico por imagen , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Betacoronavirus/aislamiento & purificación , COVID-19 , Infecciones por Coronavirus/epidemiología , Infecciones por Coronavirus/virología , Femenino , Humanos , Pulmón/diagnóstico por imagen , Pulmón/patología , Pulmón/virología , Enfermedades Pulmonares/patología , Masculino , Persona de Mediana Edad , Pandemias , Neumonía Viral/epidemiología , Neumonía Viral/virología , Radiografía Torácica/métodos , Estudios Retrospectivos , SARS-CoV-2 , Tomografía Computarizada por Rayos X/métodos , Adulto Joven
6.
Heart Fail Rev ; 25(5): 847-860, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-31446536

RESUMEN

A systematic review and meta-analysis were performed to analyse the differences in clinical profiles between takotsubo syndrome (TTS) and acute coronary syndrome (ACS) patients and to consolidate the evidence regarding the mortality predictors in TTS patients. Literature search of PubMed, EMBASE and the Cochrane Central Register was made, and 55 studies with a total of 66,653 TTS patients were included. Compared with ACS subjects, TTS subjects had significantly lower left ventricle ejection fraction (LVEF) values on admission; however, cardiovascular risks were fewer and the recovery LVEF was notably higher at both discharge and follow-up in TTS patients than in ACS patients (all P < 0.05). No significant differences were observed either in-hospital mortality or long-term mortality between the two groups (both P > 0.05). Acute renal failure and malignancies were independent predictors of all-cause in-hospital mortality in TTS patients (both P < 0.05). Male sex (HR = 0.565, 95% CI 0.253-0.876, P < 0.001, I2 = 0.00%), advanced age (HR = 0.054, 95% CI 0.041 to 0.067, P < 0.001, I2 = 0.00%), shock (HR = 1.382. 95% CI 1.050 to 1.714, P < 0.001, I2 = 0.00%) and initial LVEF < 35% (HR = 0.962, 95% CI 0.948 to 0.977, P < 0.001, I2 = 16.8%) were associated with an increased risk of long-time mortality in TTS patients. In conclusion, TTS has significantly different clinical characteristics than ACS. However, the in-hospital and long-term overall mortality rates are not trivial for TTS patients, and some presenting features (underlying diseases, male sex, advanced age, low LVEF and shock) were significantly associated with all-cause mortality.


Asunto(s)
Síndrome Coronario Agudo/diagnóstico , Volumen Sistólico/fisiología , Cardiomiopatía de Takotsubo/diagnóstico , Función Ventricular Izquierda/fisiología , Síndrome Coronario Agudo/fisiopatología , Humanos , Pronóstico , Cardiomiopatía de Takotsubo/fisiopatología
7.
Eur Radiol ; 30(8): 4705-4708, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32215692

RESUMEN

The original version of this article, published on 27 May 2019, unfortunately contained mistakes.

8.
BMC Cardiovasc Disord ; 20(1): 25, 2020 01 17.
Artículo en Inglés | MEDLINE | ID: mdl-31952479

RESUMEN

BACKGROUND: Most reported cases of right anomalous coronary artery from the opposite sinus (R-ACAOS) have benign clinical outcomes. However, patients with left ACAOS (L-ACAOS) and some of the patients with R-ACAOS are more at risk for arrhythmias and sudden cardiac death, which remains a major concern. Here we report the prevalence and anatomical features of ACAOS patients. Moreover, we explore the high-risk morphological signs and evaluate their mid-term prognostic value in R-ACAOS patients without surgical intervention. METHODS: Data from coronary computed tomography angiography (CTA) of 30,593 patients, pertaining to a single center over 5 consecutive years, were retrospectively analyzed. The image analysis included stenosis severity ranking and high-risk anatomy evaluation, based on the commercially available image post-processing software OsirX. Patients with R-ACAOS and without evidence of coronary atherosclerosis (CAD) were followed-up, with recording of the cardiovascular clinical events. Cox regression analysis was performed to identify the potential anatomical risk factors of cardiovascular clinical events for non-CAD R-ACAOS patients, using R project. RESULTS: The prevalence of ACAOS in the study population was 0.69% (211/30593). Significant differences were found between patients with mild (< 50%) and severe (> 50%) stenosis, in terms of height-to-weight ratio (HW ratio), take-off angle, and proximal stenosis length. A total of 54 cardiovascular clinical events were observed among 108 non-CAD R-ACAOS patients and an average follow-up of 27.8 ± 18.7 months. Among those patients' anatomical features, stenosis severity was the main risk factor for cardiovascular clinical events during the mid-term follow-up, with a risk ratio of 4.14 (95% CI: 1.78 to 9.63, P < 0.001). CONCLUSIONS: Among patients referred to coronary CTA, the overall incidence of ACAOS was 0.69%. For patients with R-ACAOS, severe stenosis was the independent risk factor of adverse clinical events in the mid-term follow-up, and positive clinical intervention might be needed to help them avoid the malignant clinical events.


Asunto(s)
Angiografía por Tomografía Computarizada , Angiografía Coronaria , Seno Coronario/anomalías , Seno Coronario/diagnóstico por imagen , Estenosis Coronaria/diagnóstico por imagen , Anomalías de los Vasos Coronarios/diagnóstico por imagen , Adulto , Anciano , China/epidemiología , Estenosis Coronaria/epidemiología , Estenosis Coronaria/terapia , Anomalías de los Vasos Coronarios/epidemiología , Anomalías de los Vasos Coronarios/terapia , Femenino , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Prevalencia , Pronóstico , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo
9.
Heart Fail Rev ; 24(3): 325-333, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30523513

RESUMEN

Some randomized controlled trials (RCTs) have tested the efficacy of beta-blockers as prophylactic agents on cancer therapy-induced cardiotoxicity; however, the quality of this evidence remains undetermined. This systematic review and meta-analysis study aims to evaluate the prophylactic effects of beta-blockers, especially carvedilol, on chemotherapy-induced cardiotoxicity. RCTs were identified by searching the MEDLINE (PubMed), Embase (OvidSP), Cochrane CENTRAL (OvidSP), etc., until December 2017. Inclusion criteria were randomized clinical trial and adult cancer patients started beta-blockers before chemotherapy. We evaluated the mean differences (MD) by fixed- or random-effects model and the odds ratio by Peto's method. Primary outcome was the left ventricular ejection fraction (LVEF) of patients after chemotherapy, and secondary outcomes were all-cause mortality, clinically overt cardiotoxicity, and other echocardiographic measurements. In total, we included six RCTs that used carvedilol as a prophylactic agent in patients receiving chemotherapy. The LVEF was not significantly distinct between those using carvedilol and placebo after chemotherapy (MD, 1.74; 95% confidence interval (CI), - 0.18 to 3.66; P = 0.08). The incidence of clinically overt cardiotoxicity was lower in the carvedilol group compared with the control group (Peto OR, 0.42; 95% CI, 0.20-0.89; P = 0.02). Furthermore, after chemotherapy, the LV end-diastolic diameter did not increase in the carvedilol group compared with the placebo group (MD, - 1.41; 95% CI, - 2.32 to - 0.50; P = 0.002). The prophylactic use of carvedilol exerted no impact on the early asymptomatic LVEF decrease but seemed to attenuate the frequency of clinically overt cardiotoxicity and prevent ventricular remodeling.


Asunto(s)
Antagonistas Adrenérgicos beta/uso terapéutico , Cardiotoxicidad/epidemiología , Cardiotoxicidad/prevención & control , Carvedilol/uso terapéutico , Sustancias Protectoras/uso terapéutico , Adulto , Anciano , Antineoplásicos/efectos adversos , Cardiotoxicidad/etiología , Cardiotoxicidad/mortalidad , Ecocardiografía , Femenino , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda/efectos de los fármacos , Remodelación Ventricular/efectos de los fármacos , Adulto Joven
10.
Cardiovasc Diabetol ; 18(1): 123, 2019 09 24.
Artículo en Inglés | MEDLINE | ID: mdl-31551077

RESUMEN

BACKGROUND: Patients with Diabetes mellitus (DM) are susceptible to coronary artery disease (CAD). However, the impact of DM on plaque progression in the non-stented segments of stent-implanted patients has been rarely reported. This study aimed to evaluate the impact of DM on the prevalence, characteristics and severity of coronary computed tomography angiography (CCTA) verified plaque progression in stented patients. A comparison between diabetic and non-diabetic patients was performed. METHODS: A total of 98 patients who underwent clinically indicated serial CCTAs arranged within 1 month before and at least 6 months after percutaneous coronary intervention (PCI) were consecutively included. All the subjects were categorized into diabetic group (n = 36) and non-diabetic groups (n = 62). Coronary stenosis extent scores, segment involvement scores (SIS), segment stenosis scores (SSS) at baseline and follow-up CCTA were quantitatively assessed. The prevalence, characteristics and severity of plaque progression was evaluated blindly to the clinical data and compared between the groups. RESULTS: During the median 1.5 year follow up, a larger number of patients (72.2% vs 40.3%, P = 0.002), more non-stented vessels (55.7% vs 23.2%, P < 0.001) and non-stented segments (10.3% vs 4.4%, P < 0.001) showed plaque progression in DM group, compared to non-DM controls. More progressive lesions in DM patients were found to be non-calcified plaques (31.1% vs 12.8%, P = 0.014) or non-stenotic segments (6.6% vs 3.0%, p = 0.005) and were more widely distributed on left main artery (24.2% vs 5.2%, p = 0.007), the right coronary artery (50% vs 21.1%, P = 0.028) and the proximal left anterior artery (33.3% vs 5.1%, P = 0.009) compared to non-DM patients. In addition, DM patients possessed higher numbers of progressive segments per patient, ΔSIS and ΔSSS compared with non-DM individuals (P < 0.001, P = 0.029 and P < 0.001 respectively). A larger number of patients with at least two progressive lesions were found in the DM group (P = 0.006). Multivariate logistic regression analysis demonstrated that DM (OR: 4.81; 95% CI 1.64-14.07, P = 0.004) was independently associated with plaque progression. CONCLUSIONS: DM is closely associated with the prevalence and severity of CCTA verified CAD progression. These findings suggest that physicians should pay attention to non-stent segments and the management of non-stent segment plaque progression, particularly to DM patients.


Asunto(s)
Angiografía por Tomografía Computarizada , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/terapia , Estenosis Coronaria/terapia , Vasos Coronarios/diagnóstico por imagen , Diabetes Mellitus/epidemiología , Intervención Coronaria Percutánea/instrumentación , Placa Aterosclerótica , Stents , Anciano , Anciano de 80 o más Años , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/epidemiología , Enfermedad de la Arteria Coronaria/patología , Estenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/epidemiología , Estenosis Coronaria/patología , Vasos Coronarios/patología , Diabetes Mellitus/diagnóstico , Progresión de la Enfermedad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Valor Predictivo de las Pruebas , Prevalencia , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Resultado del Tratamiento
11.
Eur Radiol ; 29(12): 6816-6828, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31134368

RESUMEN

OBJECTIVE: Right ventricular function (RVF) is a strong predictor of adverse cardiac events; however, the reference standard for RVF assessment, MRI, is limited in some patients for whom accurate evaluation of RVF is essential, like those with COPD or non-MR compatible metal implants. We conducted this meta-analysis to evaluate whether CT was as accurate as MRI for the assessment of RVF. METHOD: We conducted a meta-analysis of studies retrieved from PubMed, Embase, and Cochrane Central searches to evaluate the differences and correlations between the following RVF parameters as measured by CT and MRI: end diastole volume (EDV), end systole volume (ESV), right ventricular ejection fraction (RVEF), and stroke volume (SV). RESULTS: Sixteen studies that used disk summation (637 subjects) and three studies that used three-dimensional reconstruction were included. For the 16 studies, the pooled standard mean differences (95% confidence interval) were 1.04 (- 2.59, 4.67) for EDV, 1.22 (1.50, 3.95) for ESV, - 0.65 (- 2.60, 1.29) for RVEF, and - 0.37 (- 3.64, 2.90) for SV. The overall correlation coefficient (r) values were 0.98 for EDV, 0.95 for ESV, 0.98 for RVEF, and 0.97 for SV. The mean difference between the two methods was not statistically significant (overall effect Z test, p > 0.1). CONCLUSION: CT can assess RVF with accuracy comparable to that of MRI. Thus, CT is a valid alternative to MRI. KEY POINTS: • CT could help clinicians to assess RVF as accurately as MRI can, with satisfactory repeatability.


Asunto(s)
Ventrículos Cardíacos/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Tomografía Computarizada por Rayos X/métodos , Disfunción Ventricular Derecha/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Volumen Sistólico , Función Ventricular Derecha
12.
Sichuan Da Xue Xue Bao Yi Xue Ban ; 50(6): 878-883, 2019 Dec.
Artículo en Zh | MEDLINE | ID: mdl-31880121

RESUMEN

ObstractPurpose "One-stop" CT myocardial perfusion imaging (CT-MPI) was compared with cardiac magnetic resonance(CMR) to investigate its application value in evaluating patients with severe coronary artery stenosis.MethodsFifty patients with coronary artery stenosis≥90% of at least one major coronary arteries comfirmed by coronary angiography (CAG) in the department of cardiology in our hospital, who referred for coronary artery stent implantation were prospectively enrolled. All the patients underwent "One-stop" CT-MPI within a week before surgery, among which 22 patients underwent CMR examination simultaneously. The postprocessing software Ziostation2 was used to obatin and compare the perfusion parameters of patients with normal and perfusion defect myocardium, including blood flow (BF), blood volume (BV), peak time (TTP), and mean transit time (MTT). Pearson correlation analysis was used to compare the correlation of relative perfusion parameters (defect/normal myocardium) between CT and CMR. Bland-Altman analysis was used to analyze the consistency between CT and CMR in left ventricular (LV) function parameters measurements.ResultsCompared with normal myocardium, BV and BF of perfusion defect myocardium were significantly decreased, while MTT and TTP were significantly prolonged (all P < 0.05). The rBV, rBF, rMTT and rTTP were medium to high positive correlated between CT and CMR (r=0.685, 0.641, 0.871, 0.733, respectively, all P < 0.05). Bland-Altman analysis showed that 95% (21/22) points were within the 95% limits of agreement (LoA), suggesting the LV function parameters measurements between two methods were highly consistent.Conclusion"One-stop" CT-MPI can simultaneously obtain the information about coronary anatomy, myocardial perfusion and LV function. It is of great value in the evaluation of patients with severe coronary artery stenosis, with shorter scan time and less contraindications compared with CMR.


Asunto(s)
Enfermedad de la Arteria Coronaria , Estenosis Coronaria , Imagen de Perfusión Miocárdica , Angiografía Coronaria , Humanos , Valor Predictivo de las Pruebas , Tomografía Computarizada por Rayos X
13.
Cardiovasc Diabetol ; 17(1): 139, 2018 10 30.
Artículo en Inglés | MEDLINE | ID: mdl-30373588

RESUMEN

BACKGROUND: Early detection of subclinical myocardial dysfunction in patients with diabetes mellitus (DM) is essential for recommending therapeutic interventions that can prevent or reverse heart failure, thereby improving the prognosis in such patients. This study aims to quantitatively evaluate left ventricular (LV) myocardial deformation and perfusion using cardiovascular magnetic resonance (CMR) imaging in patients with type 2 diabetes mellitus (T2DM), and to investigate the association between LV subclinical myocardial dysfunction and coronary microvascular perfusion. METHODS: We recruited 71 T2DM patients and 30 healthy individuals as controls who underwent CMR examination. The T2DM patients were subdivided into two groups, namely the newly diagnosed DM group (n = 31, patients with diabetes for ≤ 5 years) and longer-term DM group (n = 40, patients with diabetes > 5 years). LV deformation parameters, including global peak strain (PS), peak systolic strain rate, and peak diastolic strain rate (PSDR), and myocardial perfusion parameters such as upslope, time to maximum signal intensity (TTM), and max signal intensity (Max SI, were measured and compared among the three groups. Pearson's correlation was used to evaluate the correlation between LV deformation and perfusion parameters. RESULTS: Pooled data from T2DM patients showed a decrease in global longitudinal, circumferential, and radial PDSR compared to healthy individuals, apart from lower upslope. In addition, increased TTM and reduced Max SI were found in the longer-term diabetics compared to the normal subjects (p < 0.017 for all). Multivariable linear regression analysis showed that T2DM was independently associated with statistically significant CMR parameters, except for TTM (ß = 0.137, p = 0.195). Further, longitudinal PDSR was significantly associated with upslope (r = - 0.346, p = 0.003) and TTM (r = 0.515, p < 0.001). CONCLUSIONS: Our results imply that a contrast-enhanced 3.0T CMR can detect subclinical myocardial dysfunction and impaired myocardial microvascular perfusion in the early stages of T2DM, and that the myocardial dysfunction is associated with impaired coronary microvascular perfusion.


Asunto(s)
Medios de Contraste/administración & dosificación , Circulación Coronaria , Diabetes Mellitus Tipo 2/complicaciones , Cardiomiopatías Diabéticas/diagnóstico por imagen , Imagen por Resonancia Magnética , Imagen de Perfusión Miocárdica/métodos , Disfunción Ventricular Izquierda/diagnóstico por imagen , Función Ventricular Izquierda , Adulto , Enfermedades Asintomáticas , Estudios de Casos y Controles , Diabetes Mellitus Tipo 2/diagnóstico , Diabetes Mellitus Tipo 2/fisiopatología , Cardiomiopatías Diabéticas/etiología , Cardiomiopatías Diabéticas/fisiopatología , Diagnóstico Precoz , Femenino , Humanos , Masculino , Microcirculación , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Factores de Riesgo , Disfunción Ventricular Izquierda/etiología , Disfunción Ventricular Izquierda/fisiopatología
14.
BMC Cardiovasc Disord ; 18(1): 124, 2018 06 22.
Artículo en Inglés | MEDLINE | ID: mdl-29929466

RESUMEN

BACKGROUND: Coarctation of aorta (CoA) may progressively develop aortic dilation at other site of the aorta and can lead to fatal aortic diseases. We aimed to evaluate the occurrence of aortic dilation and related predictors in patients with CoA using dual-source computed tomography (DSCT). METHODS: Fifty-three patients with CoA identified by DSCT were retrospectively reviewed. Aortic diameters were measured at six different levels and standardized as z-scores based on the square root of body surface area. Coarctation site-diaphragm ratio (CDR) was used to describe the degree of narrowing. A total of 26 patients were included in mild group (CDR > 50%) and 27 in severe group (CDR < 50%) according to the severity of coarctation. Student's t-test and Spearman correlation coefficients, univariate and multivariable logistic regression analyses were used to assess the risk factors including age, degree of narrowing and other malformations for aortic dilation. RESULTS: Severe group had significantly larger z-scores of ascending aorta (2.41 ± 0.39 vs. 2.10 ± 0.57, p < 0.05) and post-coarctation aorta (2.17 ± 0.48 vs. 1.68 ± 0.43, p < 0.001) compared with mild group. Degree of coarctation was associated with the z-scores of the ascending aorta (r = - 0.356, p < 0.05) and post-coarctation aorta (r = - 0.414, p < 0.05). Collateral circulation was related to the z-scores of ascending aorta (r = 0.375, p < 0.05). Increased severity of coarctation was independent predictor of ascending (odds ratio 7.46; 95% CI 1.19-46.76; p < 0.05) and post-coarctation aortic dilation(odds ratio 8.42; 95% CI 1.84-38.56; p < 0.05). CONCLUSIONS: Ascending and post-coarctation aortic diameters or dilations were both associated with the degree of coarctation. By comprehensively evaluating the aortic diameters and associated malformations including collateral circulation, DSCT can aid in stratification of risk for aortic dilation in patients with CoA.


Asunto(s)
Aorta/diagnóstico por imagen , Aneurisma de la Aorta/diagnóstico por imagen , Coartación Aórtica/diagnóstico por imagen , Aortografía/métodos , Angiografía por Tomografía Computarizada , Adolescente , Adulto , Aorta/patología , Aorta/fisiopatología , Aneurisma de la Aorta/etiología , Aneurisma de la Aorta/patología , Aneurisma de la Aorta/fisiopatología , Coartación Aórtica/complicaciones , Coartación Aórtica/patología , Coartación Aórtica/fisiopatología , Niño , Circulación Colateral , Dilatación Patológica , Femenino , Humanos , Masculino , Valor Predictivo de las Pruebas , Pronóstico , Flujo Sanguíneo Regional , Estudios Retrospectivos , Factores de Riesgo , Índice de Severidad de la Enfermedad , Adulto Joven
15.
BMC Cardiovasc Disord ; 17(1): 285, 2017 Dec 04.
Artículo en Inglés | MEDLINE | ID: mdl-29202750

RESUMEN

BACKGROUND: To investigate the diagnostic value of dual-source computed tomography (DSCT) in the evaluation of tetralogy of Fallot (TOF)-associated extracardiac vascular abnormalities in pediatric patients compared with transthoracic echocardiography (TTE). METHODS: One hundred and twenty-three pediatric patients diagnosed with TOF were included in this retrospective study. All patients underwent DSCT and TTE preoperatively. All associated extracardiac vascular abnormalities and their percentages were recorded. The diagnostic performances of DSCT and TTE were compared based on the surgical results. The image quality of DSCT was rated, and the effective radiation dose (ED) was calculated. RESULTS: A total of 159 associated extracardiac vascular deformities were confirmed by surgery. Patent ductus arteriosus (36, 22.64%), right-sided aortic arch (29, 18.24%), and pulmonary valve stenosis (23, 14.47%) were the most common associated extracardiac vascular abnormalities. DSCT was superior to TTE in demonstrating associated extracardiac anomalies (diagnostic accuracy: 99.13% vs. 97.39%; sensitivity: 92.45% vs. 77.07%; specificity: 99.81% vs. 99.42%). The agreement on grading the image quality of DSCT was excellent (κ = 0.80), and the mean score of the image quality was 3.39 ± 0.50. The mean ED of DSCT was 0.86 ± 0.47 mSv. CONCLUSIONS: Compared to TTE, low-dose DSCT has high diagnostic accuracy in the depiction of associated extracardiac vascular anomalies in pediatric patients with TOF, and could provide more morphological details for surgeons.


Asunto(s)
Ecocardiografía , Dosis de Radiación , Tetralogía de Fallot/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Malformaciones Vasculares/diagnóstico por imagen , Factores de Edad , Niño , Preescolar , Femenino , Humanos , Lactante , Masculino , Valor Predictivo de las Pruebas , Exposición a la Radiación/efectos adversos , Exposición a la Radiación/prevención & control , Reproducibilidad de los Resultados , Estudios Retrospectivos , Factores de Riesgo , Tomografía Computarizada por Rayos X/efectos adversos
16.
J Cardiovasc Magn Reson ; 18(1): 92, 2016 Dec 12.
Artículo en Inglés | MEDLINE | ID: mdl-27955698

RESUMEN

BACKGROUND: Myocardial fibrosis is being increasingly recognised as a common final pathway of a wide range of diseases. Thus, the development of an accurate and convenient method to evaluate myocardial fibrosis is of major importance. Although T1 mapping is a potential alternative for myocardial biopsy, validation studies are limited to small numbers and vary regarding technical facets, and include only a restricted number of disease. A systematic review and meta-analysis was conducted to objectively and comprehensively evaluate the performance of T1 mapping on the quantification of myocardial fibrosis using cardiovascular magnetic resonance (CMR). METHODS: PubMed, EMBASE and the Cochrane Library databases were searched for studies applying T1 mapping to measure myocardial fibrosis and that validated the results via histological analysis. A pooled correlation coefficient between the CMR and histology measurements was used to evaluate the performance of the T1 mapping. RESULTS: A total of 15 studies, including 308 patients who had CMR and myocardial biopsy were included and the pooled correlation coefficient between ECV measured by T1 mapping and biopsy for the selected studies was 0.884 (95% CI: 0.854, 0.914) and was not notably heterogeneous chi-squared = 7.44; P = 0.489 for the Q test and I^2 = 0.00%). CONCLUSIONS: The quantitative measurement of myocardial fibrosis via T1 mapping is associated with a favourable overall correlation with the myocardial biopsy measurements. Further studies are required to determine the calibration of the T1 mapping results for the biopsy findings of different cardiomyopathies.


Asunto(s)
Cardiopatías/diagnóstico por imagen , Cardiopatías/patología , Imagen por Resonancia Magnética , Miocardio/patología , Biopsia , Distribución de Chi-Cuadrado , Fibrosis , Humanos , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados
18.
Artículo en Inglés | MEDLINE | ID: mdl-39039380

RESUMEN

The value of cardiovascular magnetic resonance (CMR) in assessing and predicting acute right ventricular (RV) dysfunction in patients with anterior ST-segment elevation myocardial infarction (STEMI) remains ascertained. Eighty eight patients with anterior STEMI were prospectively recruited and underwent CMR examinations within one week following the coronary intervention. Patients with RV ejection fraction (RVEF) less than 2 standard deviations below the average at the center (RVEF ≤ 45.0%) were defined as having RV dysfunction. The size of infarction, segmental wall motion, and T1 and T2 mapping values of global myocardium and the interventricular septum (IVS) were measured. Predictive performance was calculated using receiver-operating characteristic curve analysis and logistic regression test. Twenty two patients presented with RV dysfunction. The RV dysfunction group had a larger IVS infarct extent (54.28 ± 10.35 vs 33.95 ± 15.09%, P < 0.001) and lower left ventricle stroke volume index (33.93 ± 7.96 vs 42.46 ± 8.14 ml/m2, P < 0.001) compared to the non-RV dysfunction group. IVS infarct extent at 48.8% best predicted the presence of RV dysfunction with an area under the curve of 0.864. Left ventricular stroke volume index (LVSVI) and IVS infarct extent were selected by stepwise multivariable logistic regression analysis. Lower LVSVI (odds ratio [OR] 0.90; 95% confidence interval [CI], 0.79 to 0.99; P = 0.044) and higher IVS infarct extent (OR 1.16; 95% CI 1.05 to 1.33; P = 0.01) were found to be independent predictors for RV dysfunction. In patients with anterior STEMI, those with larger IVS infarct extent and worse LV function are more likely to be associated with RV dysfunction.

19.
Quant Imaging Med Surg ; 14(2): 1860-1872, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38415146

RESUMEN

Background: For patients with suspected simultaneous coronary and cerebrovascular atherosclerosis, conventional single-site computed tomography angiography (CTA) for both sites can result in nonnegligible radiation and contrast agent dose. The purpose of this study was to validate the feasibility of one-stop coronary and carotid-cerebrovascular CTA (C&CC-CTA) with a "double-low" (low radiation and contrast) dose protocol reconstructed with deep learning image reconstruction with high setting (DLIR-H) algorithm. Methods: From February 2018 to January 2019, 60 patients referred to C&CC-CTA simultaneously in West China Hospital were recruited in this prospective cohort study. By random assignment, patients were divided into two groups: double-low dose group (n=30) used 80 kVp and 24 mgI/kg/s contrast dose with images reconstructed using DLIR-H; and routine-dose group (n=30) used 100 kVp and 32 mgI/kg/s contrast dose with images reconstructed using 50% adaptive statistical iterative reconstruction-V (ASIR-V50%). Radiation and contrast doses, subjective image quality score, CT attenuation values, noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were measured and compared between the groups. Results: The DLIR-H group used 30% less contrast dose (35.80±4.85 vs. 51.13±6.91 mL) and 48% less overall radiation dose (1.00±0.09 vs. 1.91±0.42 mSv) than the ASIR-V50% group (both P<0.001). There was no statistically significant difference on subjective quality score between the two groups (C-CTA: 4.38±0.67 vs. 4.17±0.81, P=0.337 and CC-CTA: 4.18±0.87 vs. 4.08±0.79, P=0.604). For coronary CTA, lower background noise (18.93±1.43 vs. 22.86±3.75 HU) was reached in DLIR-H group, and SNR and CNR at all assessed branches were significantly increased compared to ASIR-V50% group (all P<0.05), except SNR of left anterior descending (P>0.05). For carotid-cerebrovascular CTA, DLIR-H group was comparable in background noise (19.25±1.42 vs. 20.23±2.40 HU), SNR and CNR at all assessed branches with ASIR-V50% group (all P>0.05). Conclusions: The "double-low" dose one-stop C&CC-CTA with DLIR-H obtained higher image quality compared with the routine-dose protocol with ASIR-V50% while achieving 48% and 30% reduction in radiation and contrast dose, respectively.

20.
Quant Imaging Med Surg ; 13(10): 6456-6467, 2023 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-37869326

RESUMEN

Background: Computed tomography angiography (CTA) is the recommended diagnostic and follow-up imaging modality for acute aortic dissection (AD). However, the high-contrast medium burden associated with repeated CT aortography follow-ups remains a significant concern. This prospective study aimed to assess whether an ultra-low contrast dose (75% cutoff) aortic CTA protocol on dual-layer spectral CT could achieve comparable image quality with the full dose protocol. We also investigated the image quality of the virtual noncontrast (VNC) images derived from the ultra-low dose protocol. Methods: This study included 37 consecutive patients who were referred to aortic CTA from May 2022 to August 2022. The enrolled patients underwent full-dose contrast CTA and ultra-low dose (reduced to 25% of conventional) contrast CTA on dual-layer spectral CT in 1 day. Virtual monochromatic images (VMIs) were reconstructed with 40 and 70 keV. The VNC images were reconstructed for both protocols. Objective image quality evaluation, recorded as signal-to-noise ratios (SNRs) and contrast-to-noise ratios (CNRs), was compared between the groups using 1-way analysis of variance and post hoc analysis with Bonferroni correction. Subjective image quality was also compared between the groups. Finally, VNC images derived from the low-dose (VNClow) and full-dose (VNCfull) protocols were compared to the true noncontrast (TNC) images. Results: Neither CNR nor SNR was lower for the 40-keV images reconstructed from the ultra-low dose group compared to the conventional images. Both were significantly higher than those of the 70-keV images. Regarding subjective image quality, vessel enhancement was not significantly different between the 40-keV VMI and full-dose images [ascending aorta (AAO): 4.37±0.46 vs. 4.57±0.48, P=0.096; brachiocephalic arteries: 4.34±0.45 vs. 4.51±0.49, P=0.152; abdominal aortic side branch: 4.42±0.48 vs. 4.51±0.49, P=0.480]. The VNClow images were similar to the TNC images but significantly different from the VNCfull images (P<0.001). Conclusions: Ultra-low contrast aortic CTA with a 75%-reduced iodine dose using dual-layer spectral CT and the derived VNC achieved image quality comparable to that of conventional CTA and TNC images.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA