RESUMEN
BACKGROUND: Understanding immunogenicity and effectiveness of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) vaccines is critical to guide rational use. METHODS: We compared the immunogenicity of mRNA-1273, BNT-162b2, and Ad26.COV2.S in healthy ambulatory adults. We performed an inverse-variance meta-analysis of population-level effectiveness from public health reports inâ >â 40 million individuals. RESULTS: A single dose of either mRNA vaccine yielded comparable antibody and neutralization titers to convalescent individuals. Ad26.COV2.S yielded lower antibody concentrations and frequently undetectable neutralization titers. Bulk and cytotoxic T-cell responses were higher in mRNA1273 and BNT162b2 than Ad26.COV2.S recipients. Regardless of vaccine, <50% of vaccinees demonstrated CD8+ T-cell responses. Antibody concentrations and neutralization titers increased comparably after the first dose of either vaccine, and further in recipients of a second dose. Prior infection was associated with high antibody concentrations and neutralization even after a single dose and regardless of vaccine. Neutralization of Beta, Gamma, and Delta strains were poorer regardless of vaccine. In meta-analysis, relative to mRNA1273 the effectiveness of BNT162b2 was lower against infection and hospitalization, and Ad26COV2.S was lower against infection, hospitalization, and death. CONCLUSIONS: Variation in the immunogenicity correlates with variable effectiveness of the 3 vaccines deployed in the United States.
Asunto(s)
Ad26COVS1 , COVID-19 , Vacuna nCoV-2019 mRNA-1273 , Adulto , Vacuna BNT162 , COVID-19/prevención & control , Vacunas contra la COVID-19 , Humanos , Inmunogenicidad Vacunal , SARS-CoV-2/genética , Vacunas Sintéticas , Vacunas de ARNmRESUMEN
The impact of coronavirus disease 2019 vaccination on viral characteristics of breakthrough infections is unknown. In this prospective cohort study, incidence of severe acute respiratory syndrome coronavirus 2 infection decreased following vaccination. Although asymptomatic positive tests were observed following vaccination, the higher cycle thresholds, repeat negative tests, and inability to culture virus raise questions about their clinical significance.
Asunto(s)
COVID-19 , COVID-19/epidemiología , COVID-19/prevención & control , Vacunas contra la COVID-19 , Personal de Salud , Humanos , Incidencia , Estudios Prospectivos , SARS-CoV-2 , VacunaciónRESUMEN
INTRODUCTION: ED health care professionals are at the frontline of evaluation and management of patients with acute, and often undifferentiated, illness. During the initial phase of the SARS-CoV-2 outbreak, there were concerns that ED health care professionals may have been at increased risk of exposure to SARS-CoV-2 due to difficulty in early identification of patients. This study assessed the seroprevalence of SARS-CoV-2 antibodies among ED health care professionals without confirmed history of COVID-19 infection at a quaternary academic medical center. METHODS: This study used a cross-sectional design. An ED health care professional was deemed eligible if they had worked at least 4 shifts in the adult emergency department from April 1, 2020, through May 31, 2020, were asymptomatic on the day of blood draw, and were not known to have had prior documented COVID-19 infection. The study period was December 17, 2020, to January 27, 2021. Eligible participants completed a questionnaire and had a blood sample drawn. Samples were run on the Roche Cobas Elecsys Anti-SARS-CoV-2 antibody assay. RESULTS: Of 103 health care professionals (16 attending physicians, 4 emergency residents, 16 advanced practice professionals, and 67 full-time emergency nurses), only 3 (2.9%; exact 95% CI, 0.6%-8.3%) were seropositive for SARS-CoV-2 antibodies. DISCUSSION: At this quaternary academic medical center, among those who volunteered to take an antibody test, there was a low seroprevalence of SARS-CoV-2 antibodies among ED clinicians who were asymptomatic at the time of blood draw and not known to have had prior COVID-19 infection.
Asunto(s)
COVID-19 , Adulto , Anticuerpos Antivirales , COVID-19/epidemiología , Estudios Transversales , Personal de Salud , Humanos , SARS-CoV-2 , Estudios SeroepidemiológicosRESUMEN
Sensitive and specific severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) serologic assays are needed to inform diagnostic, therapeutic, and public health decision-making. We evaluated three commercial serologic assays as stand-alone tests and as components of two-test algorithms. Two nucleocapsid antibody tests (Abbott IgG and Roche total antibody) and one spike protein antibody test (DiaSorin IgG) were included. We assessed sensitivity using 128 serum samples from symptomatic PCR-confirmed coronavirus disease 2019 (COVID-19)-infected patients and specificity using 1,204 samples submitted for routine serology prior to COVID-19's emergence, plus 64 pandemic-era samples from SARS-CoV-2 PCR-negative patients with respiratory symptoms. Assays were evaluated as stand-alone tests and as components of a two-test algorithm in which positive results obtained using one assay were verified using a second assay. The two nucleocapsid antibody tests were more sensitive than the spike protein antibody test overall (70% and 70% versus 57%; P ≤ 0.003), with pronounced differences observed using samples collected 7 to 14 days after symptom onset. All three assays were comparably sensitive (≥89%; P ≥ 0.13) using samples collected >14 days after symptom onset. Specificity was higher using the nucleocapsid antibody tests (99.3% and 99.7%) than using the spike protein antibody test (97.8%; P ≤ 0.002). When any two assays were paired in a two-test algorithm, the specificity was 99.9% (P < 0.0001 to 0.25 compared with the individual assays), and the positive predictive value (PPV) improved substantially, with a minimal effect on the negative predictive value (NPV). In conclusion, two nucleocapsid antibody tests outperformed a spike protein antibody test. Pairing two different serologic tests in a two-test algorithm improves the PPV, compared with the individual assays alone, while maintaining the NPV.
Asunto(s)
Anticuerpos Antivirales/sangre , Prueba Serológica para COVID-19/métodos , COVID-19/diagnóstico , Proteínas de la Nucleocápside de Coronavirus/inmunología , Glicoproteína de la Espiga del Coronavirus/inmunología , Algoritmos , Técnicas de Laboratorio Clínico/métodos , Humanos , SARS-CoV-2 , Sensibilidad y EspecificidadAsunto(s)
Muerte Súbita Cardíaca/etiología , Ácido Glicirretínico/efectos adversos , Glycyrrhiza/efectos adversos , Hiperaldosteronismo/diagnóstico , Mineralocorticoides/sangre , Aldosterona/sangre , Análisis Químico de la Sangre , Cateterismo Cardíaco , Reanimación Cardiopulmonar , Diagnóstico Diferencial , Electroencefalografía , Resultado Fatal , Ácido Glicirretínico/farmacología , Humanos , Hidrocortisona/orina , Hiperaldosteronismo/inducido químicamente , Hipopotasemia/diagnóstico , Hipopotasemia/etiología , Masculino , Persona de Mediana Edad , Tomografía Computarizada por Rayos X , Fibrilación Ventricular/complicacionesAsunto(s)
Enfermedad de Addison/diagnóstico , Hiponatremia/etiología , Enfermedad de Addison/complicaciones , Enfermedad de Addison/tratamiento farmacológico , Adulto , Aldosterona/deficiencia , Confusión/etiología , Diagnóstico Diferencial , Femenino , Humanos , Hidrocortisona/deficiencia , Concentración Osmolar , Orina/química , Vómitos/etiologíaAsunto(s)
Cobre/deficiencia , Enfermedades Carenciales/diagnóstico , Hipoestesia/etiología , Enfermedades de la Médula Espinal/diagnóstico , Zinc/efectos adversos , Enfermedades Carenciales/inducido químicamente , Enfermedades Carenciales/complicaciones , Diagnóstico Diferencial , Técnicas de Diagnóstico Neurológico , Electromiografía , Potenciales Evocados Somatosensoriales/fisiología , Femenino , Derivación Gástrica , Humanos , Persona de Mediana Edad , Debilidad Muscular/etiología , Enfermedades de la Médula Espinal/etiología , Deficiencia de Vitamina B 12/diagnóstico , Deficiencia de Vitamina E/diagnósticoRESUMEN
BACKGROUND: Increasing the value of health care delivery is a national priority, and providers face growing pressure to reduce cost while improving quality. Ample opportunity exists to increase efficiency and quality simultaneously through the application of systems engineering science. OBJECTIVE: We examined the hypothesis that Lean-based reorganization of laboratory process flow would improve laboratory turnaround times (TAT) and reduce waste in the system. METHODS: This study was a prospective, before-after analysis of laboratory process improvement in a teaching hospital emergency department (ED). The intervention included a reorganization of laboratory sample flow based in systems engineering science and Lean methodologies, with no additional resources. The primary outcome was the median TAT from sample collection to result for 6 tests previously performed in an ED kiosk. RESULTS: After the intervention, median laboratory TAT decreased across most tests. The greatest decreases were found in "reflex tests" performed after an initial screening test: troponin T TAT was reduced by 33 minutes (86 to 53 minutes; 99% confidence interval, 30-35 minutes) and urine sedimentation TAT by 88 minutes (117 to 29 minutes; 99% confidence interval, 87-90 minutes). In addition, troponin I TAT was reduced by 12 minutes, urinalysis by 9 minutes, and urine human chorionic gonadotropin by 10 minutes. Microbiology rapid testing TAT, a "control," did not change. CONCLUSIONS: In this study, Lean-based reorganization of laboratory process flow significantly increased process efficiency. Broader application of systems engineering science might further improve health care quality and capacity while reducing waste and cost.
Asunto(s)
Eficiencia Organizacional , Servicio de Urgencia en Hospital/organización & administración , Ergonomía , Laboratorios de Hospital/organización & administración , Mejoramiento de la Calidad/organización & administración , Flujo de Trabajo , Adulto , Humanos , Estudios Prospectivos , Factores de TiempoRESUMEN
OBJECTIVES: Complete blood count and differential (CBC diff) is a common laboratory test that may be overused or misordered, particularly in an inpatient setting. We assessed the ability of a clinical decision support (CDS) alert to decrease unnecessary orders for CBC diff and analyzed its impact in the laboratory. METHODS: We designed 3 CDS alerts to provide guidance to providers ordering CBC diff on inpatients at frequencies of daily, greater than once daily, or as needed. RESULTS: The 3 alerts were highly effective in reducing orders for CBC diff at the frequencies targeted by the alert. Overall, test volume for CBC diff decreased by 32% (mean of 5257 tests per month) after implementation of the alerts, with a corresponding decrease of 22% in manual differentials performed (mean of 898 per month). Turnaround time for manual differentials decreased by a mean of 41.5 minutes, with a mean decrease of up to 90 minutes during peak morning hours. CONCLUSIONS: The 3 CDS alerts successfully decreased inpatient orders for CBC diff and improved the quality of patient care by decreasing turnaround time for manual differentials.
Asunto(s)
Sistemas de Apoyo a Decisiones Clínicas , Humanos , Recuento de Células Sanguíneas , Sistemas de Entrada de Órdenes MédicasRESUMEN
OBJECTIVE: Estimated glomerular filtration rate (eGFR) calculated by cystatin C (cysC) has been recommended for broader adoption. This study assessed the discrepancy between eGFR calculated by cysC (eGFRcys) and creatinine (eGFRcr) in different patient care settings and explored potential contributing factors to such discrepancies. METHODS: This retrospective study included 2072 patients with paired cysC and creatinine results in different patient care settings. Delta eGFRcr-cys (eGFRcr - eGFRcys) was analyzed in relationship to patient care settings and the Elixhauser Comorbidity index. The 90-day survival in patients with different delta eGFR was assessed by Kaplan-Meier analysis, univariate and multivariate Cox proportional hazard models. In addition, discrepancy between eGFRcys and eGFRcr was analyzed in 50 ambulatory patients with systemic inflammation but normal kidney function. RESULTS: Inpatients had higher cysC (median 1.91 mg/L), lower eGFRcys (median 31 mL/min/1.73 m2), and larger delta eGFRcr-cys (median 18 mL/min/1.73 m2) than outpatients (cysC median 1.53 mg/L, p < 0.0001, eGFRcys median 41 mL/min/1.73 m2, p < 0.0001, delta eGFRcr-cys median 4 mL/min/1.73 m2, p < 0.0001). Higher Elixhauser Comorbidity index correlated with lower eGFRcys and larger delta eGFRcr-cys, with median delta eGFRcr-cys 11 and 6 mL/min/1.73 m2 in patients with a Comorbidity index > 15 and ≤ 15, respectively (p < 0.0001). Increased delta eGFRcr-cys was associated with worse 90-day survival. Patients with systemic inflammation but normal kidney function had lower eGFRcys (median 77.5 mL/min/1.73 m2) than eGFRcr (median 97 mL/min/1.73 m2, p < 0.001), with red blood cell abnormalities as associated factors. CONCLUSION: Inflammation and comorbidities are associated with decreased eGFRcys and large discrepancies between eGFRcr and eGFRcys independent of kidney function and are most apparent in inpatients. Creatinine-cysC combined eGFR reduces this discrepancy and should be broadly adopted.
Asunto(s)
Creatinina , Cistatina C , Tasa de Filtración Glomerular , Humanos , Cistatina C/sangre , Femenino , Masculino , Creatinina/sangre , Estudios Retrospectivos , Persona de Mediana Edad , Anciano , Atención al Paciente , Anciano de 80 o más AñosRESUMEN
Detecting genetic variants enables risk factor identification, disease screening, and initiation of preventative therapeutics. However, current methods, relying on hybridization or sequencing, are unsuitable for point-of-care settings. In contrast, CRISPR-based-diagnostics offer high sensitivity and specificity for point-of-care applications. While these methods have predominantly been used for pathogen sensing, their utilization for genotyping is limited. Here, we report a multiplexed CRISPR-based genotyping assay using LwaCas13a, PsmCas13b, and LbaCas12a, enabling the simultaneous detection of six genotypes. We applied this assay to identify genetic variants in the APOL1 gene prevalent among African Americans, which are associated with an 8-30-fold increase in the risk of developing kidney disease. Machine learning facilitated robust analysis across a multicenter clinical cohort of more than 100 patients, accurately identifying their genotypes. In addition, we optimized the readout using a multi-analyte lateral-flow assay demonstrating the ability for simplified genotype determination of clinical samples. Our CRISPR-based genotyping assay enables cost-effective point-of-care genetic variant detection due to its simplicity, versatility, and fast readout.
Asunto(s)
Apolipoproteína L1 , Sistemas de Atención de Punto , Apolipoproteína L1/genética , Humanos , Medición de Riesgo/métodos , Técnicas de Genotipaje/métodos , Sistemas CRISPR-Cas/genética , Genotipo , Repeticiones Palindrómicas Cortas Agrupadas y Regularmente Espaciadas/genética , Negro o Afroamericano/genética , Predisposición Genética a la Enfermedad , Enfermedades Renales/genética , Enfermedades Renales/diagnósticoRESUMEN
Background: Patients with predominantly antibody deficiency (PAD) have lower anti-severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) spike antibody levels after initial 2-dose SARS-CoV-2 vaccination than healthy controls do; however, the anti-spike antibody responses and neutralization function in patients with PAD following subsequent immunizations remain understudied. Objective: We sought to characterize anti-spike antibody responses in adults with PAD over the course of 5 SARS-CoV-2 vaccine doses and identify diagnostic and immunophenotypic risk factors for low antibody response. Methods: We evaluated anti-spike antibody levels in 117 adult patients with PAD and 192 adult healthy controls following a maximum of 5 SARS-CoV-2 immunizations. We assessed neutralization of the SARS-CoV-2 wild-type strain and the Omicron BA.5 variant and analyzed infection outcomes. Results: The patients with PAD had significantly lower mean anti-spike antibody levels after 3 SARS-CoV-2 vaccine doses than the healthy controls did (1,439.1 vs 21,890.4 U/mL [P < .0001]). Adults with secondary PAD, severe primary PAD, and high-risk immunophenotypes had lower mean anti-spike antibody levels following vaccine doses 2, 3, and/or 4 but not following vaccine dose 5. Compared with patients with mild and moderate PAD, patients with severe PAD had a higher rate of increase in anti-spike antibody levels over 5 immunizations. A strong positive correlation was observed between anti-spike antibody levels and neutralization of both the SARS-CoV-2 wild-type strain and the Omicron BA.5 variant. Most infections were managed on an outpatient basis. Conclusions: In all of the patients with PAD, anti-spike antibody levels increased with successive SARS-CoV-2 immunizations and were correlated with neutralization of both the SARS-CoV-2 wild-type strain and the Omicron BA.5 variant. Secondary PAD, severe primary PAD, and high-risk immunophenotypes were correlated with lower mean anti-spike antibody levels following vaccine doses 2 through 4. Patients with severe PAD had the highest rate of increase in anti-spike antibody levels over 5 immunizations. These data suggest a clinical benefit to sequential SARS-CoV-2 immunizations, particularly among high-risk patients with PAD.
RESUMEN
BACKGROUND: The failure of providers to communicate and follow up clinically significant test results (CSTR) is an important threat to patient safety. The Massachusetts Coalition for the Prevention of Medical Errors has endorsed the creation of systems to ensure that results can be received and acknowledged. METHODS: In 2008 a task force was convened that represented clinicians, laboratories, radiology, patient safety, risk management, and information systems in a large health care network with the goals of providing recommendations and a road map for improvement in the management of CSTR and of implementing this improvement plan during the sub-force sequent five years. In drafting its charter, the task broadened the scope from "critical" results to "clinically significant" ones; clinically significant was defined as any result that requires further clinical action to avoid morbidity or mortality, regardless of the urgency of that action. RESULTS: The task force recommended four key areas for improvement--(1) standardization of policies and definitions, (2) robust identification of the patient's care team, (3) enhanced results management/tracking systems, and (4) centralized quality reporting and metrics. The task force faced many challenges in implementing these recommendations, including disagreements on definitions of CSTR and on who should have responsibility for CSTR, changes to established work flows, limitations of resources and of existing information systems, and definition of metrics. CONCLUSIONS: This large-scale effort to improve the communication and follow-up of CSTR in a health care network continues with ongoing work to address implementation challenges, refine policies, prepare for a new clinical information system platform, and identify new ways to measure the extent of this important safety problem.
Asunto(s)
Continuidad de la Atención al Paciente , Diagnóstico Tardío , Técnicas y Procedimientos Diagnósticos/normas , Errores Médicos/prevención & control , Seguridad del Paciente , Dolor Abdominal/diagnóstico por imagen , Colecistitis Aguda/diagnóstico , Femenino , Humanos , Hallazgos Incidentales , Difusión de la Información/métodos , Comunicación Interdisciplinaria , Massachusetts , Persona de Mediana Edad , Metástasis de la Neoplasia , Neoplasias Ováricas/diagnóstico , Neoplasias Pélvicas , Tomografía Computarizada por Rayos XRESUMEN
Laboratory clinical decision support (CDS) typically relies on data from the electronic health record (EHR). The implementation of a sustainable, effective laboratory CDS program requires a commitment to standardization and harmonization of key EHR data elements that are the foundation of laboratory CDS. The direct use of artificial intelligence algorithms in CDS programs will be limited unless key elements of the EHR are structured. The identification, curation, maintenance, and preprocessing steps necessary to implement robust laboratory-based algorithms must account for the heterogeneity of data present in a typical EHR.
Asunto(s)
Inteligencia Artificial , Sistemas de Apoyo a Decisiones Clínicas , Registros Electrónicos de Salud , Laboratorios , AlgoritmosRESUMEN
OBJECTIVES: There is considerable variation in ordering practices for the initial laboratory evaluation of monoclonal gammopathies (MGs) despite clear society guidelines to include serum free light chain (sFLC) testing. We assessed the ability of a clinical decision support (CDS) alert to improve guideline compliance and analyzed its clinical impact. METHODS: We designed and deployed a targeted CDS alert to educate and prompt providers to order an sFLC assay when ordering serum protein electrophoresis (SPEP) testing. RESULTS: The alert was highly effective at increasing the co-ordering of SPEP and sFLC testing. Preimplementation, 62.8% of all SPEP evaluations included sFLC testing, while nearly 90% of evaluations included an sFLC assay postimplementation. In patients with no prior sFLC testing, analysis of sFLC orders prompted by the alert led to the determination that 28.9% (800/2,769) of these patients had an abnormal κ/λ ratio. In 452 of these patients, the sFLC assay provided the only laboratory evidence of a monoclonal protein. Moreover, within this population, there were numerous instances of new diagnoses of multiple myeloma and other MGs. CONCLUSIONS: The CDS alert increased compliance with society guidelines and improved the diagnostic evaluation of patients with suspected MGs.
Asunto(s)
Sistemas de Apoyo a Decisiones Clínicas , Mieloma Múltiple , Paraproteinemias , Humanos , Paraproteinemias/diagnóstico , Cadenas Ligeras de InmunoglobulinaRESUMEN
Background: Therapeutically immunosuppressed transplant recipients exhibit attenuated responses to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) vaccines. To elucidate the kinetics and variant cross-protection of vaccine-induced antibodies in this population, we conducted a prospective longitudinal study in heart and lung transplant recipients receiving the SARS-CoV-2 messenger RNA (mRNA) 3-dose vaccination series. Methods: We measured longitudinal serum antibody and neutralization responses against the ancestral and major variants of SARS-CoV-2 in SARS-CoV-2-uninfected lung (n = 18) and heart (n = 17) transplant recipients, non-lung-transplanted patients with cystic fibrosis (n = 7), and healthy controls (n = 12) before, during, and after the primary mRNA vaccination series. Results: Among healthy controls, strong anti-spike responses arose immediately following vaccination and displayed cross-neutralization against all variants. In contrast, among transplant recipients, after the first 2 vaccine doses, increases in antibody concentrations occurred gradually, and cross-neutralization was completely absent against the Omicron B.1.1.529 variant. However, most (73%) of the transplant recipients had a significant response to the third vaccine dose, reaching levels comparable to those of healthy controls, with improved but attenuated neutralization of immune evasive variants, particularly Beta, Gamma, and Omicron. Responses in non-lung-transplanted patients with cystic fibrosis paralleled those in healthy controls. Conclusions: In this prospective, longitudinal analysis of variant-specific antibody responses, lung and heart transplant recipients display delayed and defective responses to the first 2 SARS-CoV-2 vaccine doses but significantly augmented responses to a third dose. Gaps in antibody-mediated immunity among transplant recipients are compounded by decreased neutralization against Omicron variants, leaving many patients with substantially weakened immunity against currently circulating variants.