Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
J Comput Assist Tomogr ; 48(1): 49-54, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-37531634

RESUMEN

OBJECTIVE: Nonalcoholic fatty liver disease not only shares multiple risk factors with cardiovascular disease but also independently predicts its increased risk and related outcomes. Here, we evaluate reproducibility of 3-dimensional (3D) liver volume segmentation method to identify fatty liver on noncontrast cardiac computed tomography (CT) and compare measures with previously validated 2-dimensional (2D) segmentation CT criteria for the measurement of liver fat. METHODS: The study included 68 participants enrolled in the EVAPORATE trial and underwent serial noncontrast cardiac CT. Liver attenuation < 40 Hounsfield units (HU) was used for diagnosing fatty liver, as done in the MESA study. Two-dimensional and 3D segmentation of the liver were performed by Philips software. Bland-Altman plot analysis was used to assess reproducibility. RESULTS: Interreader reproducibility of 3D liver mean HU measurements was 96% in a sample of 111 scans. Reproducibility of 2D and 3D liver mean HU measurements was 93% in a sample of 111 scans. Reproducibility of change in 2D and 3D liver mean HU was 94% in 68 scans. Kappa, a measure of agreement in which the 2D and 3D measures both identified fatty liver, was excellent at 96.4% in 111 scans. CONCLUSIONS: Fatty liver can be reliably diagnosed and measured serially in a stable and reproducible way by 3D liver segmentation of noncontrast cardiac CT scans. Future studies need to explore the sensitivity and stability of measures for low liver fat content by 3D segmentation, over the current 2D methodology. This measure can serve as an imaging biomarker to understand mechanistic correlations between atherosclerosis, fatty liver, and cardiovascular disease risk.


Asunto(s)
Enfermedades Cardiovasculares , Enfermedad del Hígado Graso no Alcohólico , Humanos , Enfermedades Cardiovasculares/diagnóstico por imagen , Enfermedad del Hígado Graso no Alcohólico/diagnóstico por imagen , Reproducibilidad de los Resultados , Tomografía Computarizada por Rayos X/métodos , Ensayos Clínicos como Asunto
2.
J Cardiovasc Electrophysiol ; 33(4): 769-772, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35118754

RESUMEN

Cardiac resynchronization with defibrillator (CRT-D) malfunction can be due to various reasons, including wire injury, insulation break, battery problems, or patient factors. Undesired outcomes can be dramatically elevated in those settings, prompting early detection and proper troubleshooting. To diagnose, clinical correlation and device interrogation are vital. However, it is not uncommon to find general troubleshooting options insufficient, as highlighted in this case report. Here, we presented an unusual "head assembly separation," as the main reason for abnormal device parameters.


Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca , Terapia de Resincronización Cardíaca/efectos adversos , Dispositivos de Terapia de Resincronización Cardíaca/efectos adversos , Desfibriladores Implantables/efectos adversos , Falla de Equipo , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Humanos , Resultado del Tratamiento
3.
J Neurosci ; 40(26): 5019-5032, 2020 06 24.
Artículo en Inglés | MEDLINE | ID: mdl-32350041

RESUMEN

Even though the lateral geniculate nucleus of the thalamus (LGN) is associated with form vision, that is not its sole role. Only the dorsal portion of LGN (dLGN) projects to V1. The ventral division (vLGN) connects subcortically, sending inhibitory projections to sensorimotor structures, including the superior colliculus (SC) and regions associated with certain behavioral states, such as fear (Monavarfeshani et al., 2017; Salay et al., 2018). We combined computational, physiological, and anatomical approaches to explore visual processing in vLGN of mice of both sexes, making comparisons to dLGN and SC for perspective. Compatible with past, qualitative descriptions, the receptive fields we quantified in vLGN were larger than those in dLGN, and most cells preferred bright versus dark stimuli (Harrington, 1997). Dendritic arbors spanned the length and/or width of vLGN and were often asymmetric, positioned to collect input from large but discrete territories. By contrast, arbors in dLGN are compact (Krahe et al., 2011). Consistent with spatially coarse receptive fields in vLGN, visually evoked changes in spike timing were less precise than for dLGN and SC. Notably, however, the membrane currents and spikes of some cells in vLGN displayed gamma oscillations whose phase and strength varied with stimulus pattern, as for SC (Stitt et al., 2013). Thus, vLGN can engage its targets using oscillation-based and conventional rate codes. Finally, dark shadows activate SC and drive escape responses, whereas vLGN prefers bright stimuli. Thus, one function of long-range inhibitory projections from vLGN might be to enable movement by releasing motor targets, such as SC, from suppression.SIGNIFICANCE STATEMENT Only the dorsal lateral geniculate nucleus (dLGN) connects to cortex to serve form vision; the ventral division (vLGN) projects subcortically to sensorimotor nuclei, including the superior colliculus (SC), via long-range inhibitory connections. Here, we asked how vLGN processes visual information, making comparisons with dLGN and SC for perspective. Cells in vLGN versus dLGN had wider dendritic arbors, larger receptive fields, and fired with lower temporal precision, consistent with a modulatory role. Like SC, but not dLGN, visual stimuli entrained oscillations in vLGN, perhaps reflecting shared strategies for visuomotor processing. Finally, most neurons in vLGN preferred bright shapes, whereas dark stimuli activate SC and drive escape behaviors, suggesting that vLGN enables rapid movement by releasing target motor structures from inhibition.


Asunto(s)
Cuerpos Geniculados/fisiología , Percepción Visual/fisiología , Animales , Potenciales Evocados Visuales/fisiología , Femenino , Masculino , Ratones , Ratones Endogámicos C57BL , Vías Visuales/fisiología
4.
J Neurosci ; 36(43): 10949-10963, 2016 10 26.
Artículo en Inglés | MEDLINE | ID: mdl-27798177

RESUMEN

Comparative physiological and anatomical studies have greatly advanced our understanding of sensory systems. Many lines of evidence show that the murine lateral geniculate nucleus (LGN) has unique attributes, compared with other species such as cat and monkey. For example, in rodent, thalamic receptive field structure is markedly diverse, and many cells are sensitive to stimulus orientation and direction. To explore shared and different strategies of synaptic integration across species, we made whole-cell recordings in vivo from the murine LGN during the presentation of visual stimuli, analyzed the results with different computational approaches, and compared our findings with those from cat. As for carnivores, murine cells with classical center-surround receptive fields had a "push-pull" structure of excitation and inhibition within a given On or Off subregion. These cells compose the largest single population in the murine LGN (∼40%), indicating that push-pull is key in the form vision pathway across species. For two cell types with overlapping On and Off responses, which recalled either W3 or suppressed-by-contrast ganglion cells in murine retina, inhibition took a different form and was most pronounced for spatially extensive stimuli. Other On-Off cells were selective for stimulus orientation and direction. In these cases, retinal inputs were tuned and, for oriented cells, the second-order subunit of the receptive field predicted the preferred angle. By contrast, suppression was not tuned and appeared to sharpen stimulus selectivity. Together, our results provide new perspectives on the role of excitation and inhibition in retinothalamic processing. SIGNIFICANCE STATEMENT: We explored the murine lateral geniculate nucleus from a comparative physiological perspective. In cat, most retinal cells have center-surround receptive fields and push-pull excitation and inhibition, including neurons with the smallest (highest acuity) receptive fields. The same is true for thalamic relay cells. In mouse retina, the most numerous cell type has the smallest receptive fields but lacks push-pull. The most common receptive field in rodent thalamus, however, is center-surround with push-pull. Thus, receptive field structure supersedes size per se for form vision. Further, for many orientation-selective cells, the second-order component of the receptive field aligned with stimulus preference, whereas suppression was untuned. Thus, inhibition may improve spatial resolution and sharpen other forms of selectivity in rodent lateral geniculate nucleus.


Asunto(s)
Cuerpos Geniculados/fisiología , Red Nerviosa/fisiología , Sinapsis/fisiología , Campos Visuales/fisiología , Vías Visuales/fisiopatología , Percepción Visual/fisiología , Animales , Mapeo Encefálico , Gatos , Femenino , Masculino , Ratones , Ratones Endogámicos C57BL , Modelos Neurológicos , Inhibición Neural/fisiología , Ratas , Ratas Long-Evans , Células Ganglionares de la Retina/fisiología , Especificidad de la Especie , Transmisión Sináptica/fisiología
5.
Eur Heart J Case Rep ; 8(8): ytae340, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39104518

RESUMEN

Background: Catecholaminergic polymorphic ventricular tachycardia (CPVT) is a primary arrhythmia disorder characterized by syncope or sudden cardiac death and typically caused by a gain-of-function of the Ryanodine Receptor Type 2 (RyR2) mutation. Calmodulin is a calcium-binding protein responsible for many intracellular signalling pathways and disruptions in function or regulation may lead to potentially fatal arrhythmias. We present a case of a young patient with CPVT found to have an unusual, potentially causative, Calmodulin 2-a protein coding gene (CALM2) mutation. Case summary: A 21-year-old female with autism was brought to the ED following cardiac arrest. Bidirectional ventricular tachycardia was captured on electrocardiogram. Propranolol was initiated, and patient had no further episodes of ventricular arrhythmia. A subcutaneous implantable cardioverter defibrillator (ICD) was implanted, and further genetics testing was done. Rapid Whole Genome Sequencing (PGnome®-RAPID) resulted heterozygous variant of uncertain significance in CALM2 gene NM_001743.5 for variant c.136G>A. Discussion: To the authors' knowledge, this is the third known record of such mutation in accordance with the International Calmodulin Registry (n = 74). Identification of CALM mutations can help advance the understanding of genetic underpinnings of arrhythmias and underscore necessity of genetic screening and personalized treatment strategies. Subcutaneous ICDs offer a promising therapeutic option while minimizing risks associated with traditional transvenous ICDs.

6.
BMJ Case Rep ; 16(8)2023 Aug 16.
Artículo en Inglés | MEDLINE | ID: mdl-37586754

RESUMEN

Ascites is a condition typically attributed to liver disease but can be cardiac in aetiology as well. We report of an atypical case of pulmonary homograft failure status-post the Ross-Yacoub procedure as an underlying cause of anasarca. A man in his mid-30s with a history of congenital heart disease presented with abdominal distension and exercise intolerance. His prior history was relevant for congenital bicuspid aortic valve with critical aortic stenosis. Abdomen and pelvis CT revealed a grossly dilated inferior vena cava while transthoracic echocardiogram showed severe homograft pulmonary stenosis and regurgitation. Further investigation with cardiac MRI demonstrated severe pulmonary valve stenosis and regurgitation with significant tricuspid regurgitation and right ventricular dilatation. The transcatheter stent in the right ventricular to pulmonary artery conduit followed by transcatheter valve replacement, which resulted in full resolution of his presenting symptoms.


Asunto(s)
Estenosis de la Válvula Aórtica , Cardiopatías Congénitas , Implantación de Prótesis de Válvulas Cardíacas , Estenosis de la Válvula Pulmonar , Válvula Pulmonar , Masculino , Humanos , Ascitis/diagnóstico por imagen , Ascitis/etiología , Ascitis/cirugía , Estenosis de la Válvula Aórtica/cirugía , Cardiopatías Congénitas/complicaciones , Cardiopatías Congénitas/diagnóstico por imagen , Cardiopatías Congénitas/cirugía , Abdomen/cirugía , Estenosis de la Válvula Pulmonar/cirugía , Aloinjertos/cirugía , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Resultado del Tratamiento
7.
J Cardiovasc Med (Hagerstown) ; 24(9): 642-650, 2023 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-37409665

RESUMEN

AIM: Peri-cardiac catheterization (CC) stroke is associated with increased morbidity and mortality. Little is known about any potential difference in stroke risk between transradial (TR) and transfemoral (TF) approaches. We explored this question through a systematic review and meta-analysis. METHODS: MEDLINE, EMBASE, and PubMed were searched from 1980 to June 2022. Randomized trials and observational studies comparing radial versus femoral access CC or intervention that reported stroke events were included. A random-effects model was used for analysis. RESULTS: The total population in our 41 pooled studies comprised 1 112 136 patients - average age 65 years, women averaging 27% in TR and 31% in TF approaches. Primary analysis of 18 randomized-controlled trials (RCTs) that included a total of 45 844 patients showed that there was no statistical significance in stroke outcomes between the TR approach and the TF approach [odds ratio (OR) 0.71, 95% confidence interval (CI) 0.48-1.06, P -value = 0.013, I2 = 47.7%]. Furthermore, meta-regression analysis of RCTs including procedural duration between those two access sites showed no significance in stroke outcomes (OR 1.08, 95% CI 0.86-1.34, P -value = 0.921, I2 = 0.0%). CONCLUSIONS: There was no significant difference in stroke outcomes between the TR approach and the TF approach.


Asunto(s)
Intervención Coronaria Percutánea , Accidente Cerebrovascular , Femenino , Humanos , Anciano , Factores de Riesgo , Arteria Radial , Arteria Femoral/diagnóstico por imagen , Corazón , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Intervención Coronaria Percutánea/efectos adversos , Resultado del Tratamiento
8.
Coron Artery Dis ; 31(1): e59-e66, 2022 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-34010188

RESUMEN

BACKGROUND: Cognitive impairment has been known to be associated with negative health impacts. Several studies recently demonstrated inconsistent outcomes among cognitive impaired patients with acute coronary syndrome (ACS). Our study aimed to determine the impact of cognitive impairment for patients with ACS. METHODS: Databases were searched through October 2020. Studies reporting revascularization rates, short- and long-term mortality among ACS patients with cognitive impairment were included. Effect estimates from the individual studies were extracted and combined using random effect and generic inverse variance method of DerSimonian and Laird. RESULTS: In total, 11 observational studies were included in the analysis consisting of 810 122 ACS patients, with 3.5% cognitive impairment patients. Our analysis suggested that cognitive impairment was associated with a lower rate of percutaneous coronary intervention (PCI) [odds ratio (OR), 0.63; 95% confidence interval (CI), 0.42-0.96; I2 = 98.5%; P = 0.033]. Among patients undergoing PCI, cognitive impairment was statistically associated with increased 30-day mortality (OR, 1.34; 95% CI, 1.14-1.57; I2 = 83.1%; P < 0.001) and long-term mortality (OR, 1.80; 95% CI, 1.04-3.11; I2 = 36.3%; P = 0.034). CONCLUSION: Our study demonstrated that cognitive impairment was not only associated with lower rates of percutaneous revascularization but also with increased 30-day and long-term mortality.


Asunto(s)
Síndrome Coronario Agudo/complicaciones , Disfunción Cognitiva/etiología , Revascularización Miocárdica/métodos , Síndrome Coronario Agudo/fisiopatología , Disfunción Cognitiva/fisiopatología , Humanos , Revascularización Miocárdica/efectos adversos , Oportunidad Relativa , Intervención Coronaria Percutánea/métodos , Resultado del Tratamiento
9.
Med Sci (Basel) ; 9(2)2021 04 23.
Artículo en Inglés | MEDLINE | ID: mdl-33922524

RESUMEN

Background: Antidepressants are one of the most prescribed medications, particularly for patients with mental disorders. Nevertheless, there are still limited data regarding the risk of ventricular arrhythmia (VA) and sudden cardiac death (SCD) associated with these medications. Thus, we performed systemic review and meta-analysis to characterize the risks of VA and SCD among patients who used common antidepressants. Methods: A literature search for studies that reported risk of ventricular arrhythmias and sudden cardiac death in antidepressant use from MEDLINE, EMBASE, and Cochrane Database from inception through September 2020. A random-effects model network meta-analysis model was used to analyze the relation between antidepressants and VA/SCD. Surface Under Cumulative Ranking Curve (SUCRA) was used to rank the treatment for each outcome. Results: The mean study sample size was 355,158 subjects. Tricyclic antidepressant (TCA) patients were the least likely to develop ventricular arrhythmia events/sudden cardiac deaths at OR 0.24, 0.028-1.2, OR 0.32 (95% CI 0.038-1.6) for serotonin and norepinephrine reuptake inhibitors (SNRI), and OR 0.36 (95% CI 0.043, 1.8) for selective serotonin reuptake inhibitors (SSRI), respectively. According to SUCRA analysis, TCA was on a higher rank compared to SNRI and SSRI considering the risk of VA/SCD. Conclusion: Our network meta-analysis demonstrated the low risk of VA/SCD among patients using antidepressants for SNRI, SSRI and especially, TCA. Despite the relatively lowest VA/SCD in TCA, drug efficacy and other adverse effects should be taken into account in patients with mental disorders.


Asunto(s)
Muerte Súbita Cardíaca/epidemiología , Inhibidores de Captación de Serotonina y Norepinefrina , Antidepresivos/efectos adversos , Antidepresivos Tricíclicos/efectos adversos , Humanos , Metaanálisis en Red , Norepinefrina , Inhibidores Selectivos de la Recaptación de Serotonina/efectos adversos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA