Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Echocardiography ; 35(6): 777-784, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-29522643

RESUMEN

AIM: Two-dimensional, transthoracic echocardiography does not account for the noncircular anatomy of the left ventricular outflow tract (LVOT) and may therefore underestimate LVOT area. Fusion of computed tomography (CT)-derived LVOT area and Doppler-derived flow data has been proposed to improve assessment of aortic valve area (AVA) and classification of aortic stenosis severity. For hemodynamic reasons, effective AVA has to be smaller than anatomic AVA. The aim of the study was to test the "fusion approach" by comparing effective CT-derived AVA with anatomic AVA from CT planimetry. METHODS AND RESULTS: Data of 244 consecutive patients (mean age 81 ± 5 years, 61% female) with aortic stenosis were retrospectively analyzed comparing effective AVA (calculated from the continuity equation using CT-LVOT and transthoracic Doppler measurements) with anatomic AVA based on CT planimetry. Substituting the LVOT area from transthoracic echocardiography (TTE) by the CT-LVOT resulted in an increase in AVA from 0.74 ± 0.15 to 0.92 ± 0.18cm² (P < .01), which was larger than anatomic AVA (0.82 ± 0.15cm²). Similar results were obtained based on planimetry from transesophageal echocardiography (TEE; AVA 0.79 ± 0.14cm², P < .01 vs CT-LVOT) and in the subgroup presenting with low-gradient severe aortic stenosis and preserved ejection fraction (n = 67, AVA from TTE 0.76 ± 0.09; from CT-LVOT 0.97 ± 0.14; CT planimetry 0.86 ± 0.12; TEE planimetry 0.82 ± 0.13cm²). CONCLUSION: Fusion of CT-derived LVOT area with Doppler echocardiography results in a calculated effective AVA that is larger than the corresponding anatomic AVA. Therefore, adjustment of partition values may be warranted when using this approach.


Asunto(s)
Válvula Aórtica/diagnóstico por imagen , Ecocardiografía Doppler/métodos , Ecocardiografía Tridimensional , Ventrículos Cardíacos/diagnóstico por imagen , Hemodinámica/fisiología , Tomografía Computarizada por Rayos X/métodos , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/fisiopatología , Femenino , Estudios de Seguimiento , Ventrículos Cardíacos/fisiopatología , Humanos , Masculino , Reproducibilidad de los Resultados , Estudios Retrospectivos , Índice de Severidad de la Enfermedad
2.
Eur Heart J ; 37(28): 2263-71, 2016 Jul 21.
Artículo en Inglés | MEDLINE | ID: mdl-26446193

RESUMEN

AIMS: We sought to evaluate the frequency of early hypo-attenuated leaflet thickening (HALT) of the SAPIEN 3 transcatheter aortic valve (S3). METHODS AND RESULTS: Of 249 patients who had undergone S3 implantation, we studied 156 consecutive patients (85 women, median age 82.2 ± 5.5 years) by electrocardiogram (ECG)-triggered dual-source computed tomography angiography (CTA) after a median of 5 days post-transcatheter aortic valve implantation. The prosthesis was assessed for HALT. Apart from heparin, peri-interventional antithrombotic therapy consisted of single- (aspirin 29%) or dual- (aspirin plus clopidogrel 71%) antiplatelet therapy. Hypo-attenuated leaflet thickening was found in 16 patients [10.3% (95% confidence interval (CI) 5.5-15.0%)] of the patients. None of the baseline and procedural variables were significantly associated with HALT, nor did we find a significant association with the antithrombotic regimen, either peri-interventionally or at the time of CTA. Hypo-attenuated leaflet thickening was found in 6 of 45 patients with peri-interventional single-antiplatelet therapy and in 10 of 111 patients with dual-antiplatelet therapy at the time of intervention [13.3% (95% CI 3.4-23.3%) vs. 9% (95% CI 3.7-14.3%), P = 0.42]. Hypo-attenuated leaflet thickening was not associated with clinical symptoms, but a small, albeit significant difference in mean pressure gradient at the time of CTA (11.6 ± 3.4 vs. 14.9 ± 5.3 mmHg, P = 0.026). Full anticoagulation led to almost complete resolution of HALT in 13 patients with follow-up CTA. CONCLUSION: Irrespective of the antiplatelet regimen, early HALT occurred in 10% of our patients undergoing transcatheter aortic S3 implantation. Early HALT is clinically inapparent and reversible by full anticoagulation.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Anciano de 80 o más Años , Válvula Aórtica , Femenino , Prótesis Valvulares Cardíacas , Humanos , Masculino , Reemplazo de la Válvula Aórtica Transcatéter , Resultado del Tratamiento
3.
Eur Heart J ; 35(44): 3103-12, 2014 Nov 21.
Artículo en Inglés | MEDLINE | ID: mdl-25161181

RESUMEN

AIMS: In patients with suspected heart failure with preserved ejection fraction (HFpEF), invasive exercise testing may be considered when measurements at rest are inconclusive. However, the prognostic impact of invasive exercise testing is uncertain, so far. METHODS AND RESULTS: We retrospectively analysed mortality in 355 patients [mean age 61.2 ± 11.3 years, 235 (66.2%) women] with unexplained dyspnoea and suspected HFpEF. During an invasive haemodynamic stress test pulmonary capillary wedge pressure (PCWP) at rest and the PCWP response to exercise, expressed as the ratio of PCWP at peak exercise to workload normalized to body weight [PCWL (mmHg/W/kg)], were recorded. Both PCWP at rest and PCWL were significant and independent predictors of long-term mortality. Adding PCWL to PCWP at rest improved reclassification of patients into survivors or non-survivors with a net reclassification improvement (NRI) of 0.56 (95% CI: 0.29-0.83; P < 0.001). Ten-year mortality was 6.6% in subjects with low PCWP at rest (≤ 12 mmHg) and low PCWL (≤ 25.5 mmHg/W/kg); 28.2% in patients with low PCWP and high PCWL and 35.2% in those with high PCWP and high PCWL. Compared with patients with low PCWP and low PCWL, the adjusted hazard ratio for mortality was 2.37 (95% CI: 1.09-5.17; P = 0.029) for the low-PCWP/high-PCWL group and 4.75 (95% CI: 1.90-11.84; P < 0.001) for patients with high PCWP/high PCWL. CONCLUSION: In patients with suspected HFpEF, invasive exercise testing substantially improves prediction of long-term mortality. An excessive rise of PCWP during exercise despite normal PCWP at rest is associated with increased mortality and may be considered as early HFpEF.


Asunto(s)
Ejercicio Físico/fisiología , Insuficiencia Cardíaca/mortalidad , Volumen Sistólico/fisiología , Anciano , Presión Sanguínea/fisiología , Cateterismo Cardíaco , Femenino , Insuficiencia Cardíaca/fisiopatología , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Presión Esfenoidal Pulmonar/fisiología , Curva ROC , Estudios Retrospectivos
4.
Eur J Cardiothorac Surg ; 61(3): 657-665, 2022 Feb 18.
Artículo en Inglés | MEDLINE | ID: mdl-34643685

RESUMEN

OBJECTIVES: Abnormal invasive exercise haemodynamics in asymptomatic patients with severe mitral regurgitation were associated with higher regurgitation burden. We analysed the association between parameters of invasive exercise testing with mortality and valve surgery compared to guideline defined non-invasive criteria. METHODS: This single centre, retrospective cohort study assesses the association of invasive exercise haemodynamics and mortality with and without surgery in patients with severe mitral regurgitation and normal ejection fraction (≥55%) as primary outcome. The secondary outcome was the need for mitral valve surgery in 113 asymptomatic patients primarily managed conservatively. RESULTS: We identified 314 patients [age 59 years (standard deviation 13), 27% female] with available exercise haemodynamics with a median follow-up of 8.2 (interquartile range 5.2-11.2) years. Five-year survival rate was 93.0%. Pulmonary capillary wedge pressure at maximum exercise >30 mmHg was the only parameter independently associated with mortality after adjustment for age and guideline criteria [hazard ratio (HR) 2.7 (1.3-5.6), P = 0.007]. In the 113 patients primarily managed conservatively, maximum pulmonary capillary wedge pressure was independently associated with mitral valve surgery during follow-up in multivariable analysis (HR 2.10 (1.32-3.34), P = 0.002; after adjustment for workload and weight: HR 1.31 (1.14-1.52), P < 0.001], whereas systolic pulmonary artery pressure and current guideline criteria were not. Adding maximum pulmonary capillary wedge pressure >25 mmHg improved the predictive power of current guideline criteria for surgery (area under the curve 0.61-0.68, P = 0.02). CONCLUSIONS: Invasive exercise haemodynamics predict mortality and improve prognostic information about surgery during follow-up derived from current guideline criteria in asymptomatic patients with severe mitral regurgitation.


Asunto(s)
Insuficiencia de la Válvula Mitral , Femenino , Hemodinámica , Humanos , Masculino , Persona de Mediana Edad , Pronóstico , Presión Esfenoidal Pulmonar , Estudios Retrospectivos
5.
Eur Heart J Cardiovasc Imaging ; 17(4): 458-66, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26219296

RESUMEN

AIMS: To evaluate the feasibility of a non-contrast three-dimensional (3D)-FLASH magnetic resonance angiography (MRA) protocol for pre-procedural aortic annulus assessment for transcatheter aortic valve replacement (TAVR) in comparison with cardiac dual-source computed tomography angiography (CTA). METHODS AND RESULTS: In this prospective study, 69 of 104 consecutive patients (mean age 81.8 ± 5.4 years, 37.7% arrhythmic) with severe aortic stenosis who had undergone pre-TAVR cardiac CTA received a respiratory and ECG-triggered, non-contrast 3D-FLASH MRA at 3 T. Annular area measurements were obtained at mid-diastole for both modalities whereas maximum systolic area was assessed by CTA only. Systolic MRA dimensions were modelled, by adding the relative difference of systolic and diastolic CTA area dimensions as a corrective factor. Hypothetical prosthesis sizing was performed based on systolic CTA, diastolic, and modelled systolic MRA area measurements. MR image quality and degree of annular calcifications were evaluated using 4-point-grading scales. The mean acquisition time was 14 ± 4.2 min. The mean image quality was 3.1 ± 0.9 with only two examinations rated non-diagnostic. The mean degree of calcifications was equal. As assessed by Bland-Altman analysis, there was no relevant systematic difference between area measurements for modelled systolic MRA and systolic CTA [the mean difference -3.1 mm(2) (limits of agreement -44.4 mm(2); 38.2 mm(2))]. Agreement for hypothetical prosthesis sizing was found in 63 of 67 (94%) patients for systolic CTA and modelled systolic MRA. CONCLUSION: The employed non-contrast 3D-FLASH MRA protocol allows for reliable assessment of aortic annulus dimensions and calcifications even in the presence of arrhythmias in an all-comers pre-TAVR population. Implementation of this technique appears legitimate in patients at an increased risk for contrast-induced nephropathy.


Asunto(s)
Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Angiografía por Tomografía Computarizada , Angiografía por Resonancia Magnética , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/cirugía , Técnicas de Imagen Sincronizada Cardíacas , Medios de Contraste , Diástole , Estudios de Factibilidad , Femenino , Humanos , Interpretación de Imagen Asistida por Computador , Yopamidol/análogos & derivados , Masculino , Cuidados Preoperatorios , Estudios Prospectivos , Sístole , Reemplazo de la Válvula Aórtica Transcatéter
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA