Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
AJNR Am J Neuroradiol ; 43(6): 887-892, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35672082

RESUMEN

BACKGROUND AND PURPOSE: Differential Subsampling with Cartesian Ordering (DISCO), an ultrafast high-spatial-resolution head MRA, has been introduced. We aimed to determine the diagnostic performance of DISCO-MRA in grading residual aneurysm in comparison with TOF-MRA in patients with treated intracranial aneurysms. MATERIALS AND METHODS: Patients with endovascular treatment and having undergone DISCO-MRA, TOF-MRA, and DSA were included for review. The voxel size and acquisition time were 0.75 × 0.75 × 1 mm3/6 seconds for DISCO-MRA and 0.6 × 0.6 × 1 mm3/6 minutes for TOF-MRA. Residual aneurysms were determined using the Modified Raymond-Roy Classification on TOF-MRA and DISCO-MRA by 2 neuroradiologists independently and were compared against DSA as the reference standard. Statistical analysis was performed using the κ statistic and the χ2 test. RESULTS: Sixty-eight treated intracranial aneurysms were included. The intermodality agreement was κ = 0.82 (95% CI, 0.67-0.97) between DISCO and DSA and 0.44 (95% CI, 0.28-0.61) between TOF and DSA. Modified Raymond-Roy Classification scores matched DSA scores in 60/68 cases (88%; χ2 = 144.4, P < .001 for DISCO and 46/68 cases (68%; χ2 = 65.0, P < .001) for TOF. The diagnostic accuracy for the detection of aneurysm remnants was higher for DISCO (0.96; 95% CI, 0.88-0.99) than for TOF (0.79; 95% CI, 0.68-0.88). CONCLUSIONS: In patients with endovascularly treated intracranial aneurysms, DISCO-MRA provides superior diagnostic performance in comparison with TOF-MRA in delineating residual aneurysms in a fraction of the time.


Asunto(s)
Embolización Terapéutica , Aneurisma Intracraneal , Angiografía de Substracción Digital , Progresión de la Enfermedad , Estudios de Seguimiento , Humanos , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/terapia , Angiografía por Resonancia Magnética
2.
AJNR Am J Neuroradiol ; 41(7): 1316-1322, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32554421

RESUMEN

BACKGROUND AND PURPOSE: Pathology and microbiology results for suspected spondylodiscitis on MR imaging are often negative in up to 70% of cases. We aimed to predict whether MR imaging features will add diagnostic value when combined with clinical biomarkers to predict positive findings of spondylodiscitis on pathology and/or microbiology from percutaneous biopsy. MATERIALS AND METHODS: In this retrospective single-center institutional review board-approved study, patients with radiologically suspected spondylodiscitis and having undergone percutaneous biopsies were assessed. Demographic characteristics, laboratory values, and tissue and blood cultures were collected. Pathology and microbiology results were used as end points. Three independent observers provided MR imaging-based scoring for typical MR imaging features for spondylodiscitis. Multivariate logistic regression and receiver operating characteristic analysis were performed to determine an optimal combination of imaging and clinical biomarkers in predicting positive findings on pathology and/or microbiology from percutaneous biopsy suggestive of spondylodiscitis. RESULTS: Our patient cohort consisted of 72 patients, of whom 33.3% (24/72) had spondylodiscitis. The mean age was 63 ± 16 years with a male/female ratio of 41:31. Logistic regression revealed a combination with an area under the curve of 0.72 for pathology and 0.68 for pathology and/or microbiology. Epidural enhancement on MR imaging improved predictive performance to 0.87 for pathology and 0.78 for pathology and/or microbiology. CONCLUSIONS: Our findings demonstrate that epidural enhancement on MR imaging added diagnostic value when combined with clinical biomarkers to help predict which patients undergoing percutaneous biopsy will have positive findings for spondylodiscitis on pathology and/or microbiology.


Asunto(s)
Discitis/diagnóstico por imagen , Biopsia Guiada por Imagen/métodos , Adulto , Anciano , Discitis/microbiología , Discitis/patología , Femenino , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
3.
AJNR Am J Neuroradiol ; 41(10): 1804-1808, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32816764

RESUMEN

Coronavirus disease 2019 was declared a global pandemic by the World Health Organization on March 11, 2020. There is a scarcity of data on coronavirus disease 2019-related brain imaging features. We present 5 cases that illustrate varying imaging presentations of acute encephalopathy in patients with coronavirus disease 2019. MR features include leukoencephalopathy, diffusion restriction that involves the GM and WM, microhemorrhages, and leptomeningitis. We believe it is important for radiologists to be familiar with the neuroradiologic imaging spectrum of acute encephalopathy in the coronavirus disease 2019 population.


Asunto(s)
Betacoronavirus , Encefalopatías/diagnóstico por imagen , Infecciones por Coronavirus/complicaciones , Neumonía Viral/complicaciones , Enfermedad Aguda , Adulto , Encefalopatías/etiología , COVID-19 , Femenino , Humanos , Leucoencefalopatías/etiología , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Pandemias , SARS-CoV-2
4.
AJNR Am J Neuroradiol ; 41(8): 1361-1364, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32586968

RESUMEN

BACKGROUND AND PURPOSE: Coronavirus disease 2019 (COVID-19) is an active worldwide pandemic with diverse complications. Stroke as a presentation has not been strongly associated with COVID-19. The authors aimed to retrospectively review a link between COVID-19 and acute stroke. MATERIALS AND METHODS: We conducted a retrospective case-control study of 41 cases and 82 control subjects matched by age, sex, and risk factors. Cases were patients who underwent stroke alert imaging with confirmed acute stroke on imaging between March 16 and April 5, 2020, at 6 hospitals across New York City. Control subjects were those who underwent stroke alertimaging during the same timeframe without imaging evidence of acute infarction. Data pertaining to diagnosis of COVID-19 infection, patient demographics, and risk factors were collected. A univariate analysis was performed to assess the covariate effect of risk factors and COVID-19 status on stroke imaging with positive findings. RESULTS: The mean age for cases and controls was 65.5 ± 15.3 years and 68.8 ± 13.2 years, respectively. Of patients with acute ischemic stroke, 46.3% had COVID-19 infection compared with 18.3% of controls (P = .001). After adjusting for age, sex, and risk factors, COVID-19 infection had a significant independent association with acute ischemic stroke compared with control subjects (OR, 3.9; 95% CI, 1.7-8.9; P = .001). CONCLUSIONS: We demonstrated that COVID-19 infection is significantly associated with imaging confirmation of acute ischemic stroke, and patients with COVID-19 should undergo more aggressive monitoring for stroke.


Asunto(s)
Betacoronavirus , Infecciones por Coronavirus/complicaciones , Neumonía Viral/complicaciones , Accidente Cerebrovascular/etiología , Anciano , Anciano de 80 o más Años , Isquemia Encefálica/etiología , COVID-19 , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pandemias , Estudios Retrospectivos , Factores de Riesgo , SARS-CoV-2
5.
AJNR Am J Neuroradiol ; 40(9): 1491-1497, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31413007

RESUMEN

BACKGROUND AND PURPOSE: The Bayesian probabilistic method has shown promising results to offset noise-related variability in perfusion analysis. Using CTP, we aimed to find optimal Bayesian-estimated thresholds based on multiparametric voxel-level models to estimate the ischemic core in patients with acute ischemic stroke. MATERIALS AND METHODS: Patients with anterior circulation acute ischemic stroke who had baseline CTP and achieved successful recanalization were included. In a subset of patients, multiparametric voxel-based models were constructed between Bayesian-processed CTP maps and follow-up MRIs to identify pretreatment CTP parameters that were predictive of infarction using robust logistic regression. Subsequently CTP-estimated ischemic core volumes from our Bayesian model were compared against routine clinical practice oscillation singular value decomposition-relative cerebral blood flow <30%, and the volumetric accuracy was assessed against final infarct volume. RESULTS: In the constructed multivariate voxel-based model, 4 variables were identified as independent predictors of infarction: TTP, relative CBF, differential arterial tissue delay, and differential mean transit time. At an optimal cutoff point of 0.109, this model identified infarcted voxels with nearly 80% accuracy. The limits of agreement between CTP-estimated ischemic core and final infarct volume ranged from -25 to 27 mL for the Bayesian model, compared with -61 to 52 mL for oscillation singular value decomposition-relative CBF. CONCLUSIONS: We established thresholds for the Bayesian model to estimate the ischemic core. The described multiparametric Bayesian-based model improved consistency in CTP estimation of the ischemic core compared with the methodology used in current clinical routine.


Asunto(s)
Isquemia Encefálica/diagnóstico por imagen , Imagen de Perfusión/métodos , Accidente Cerebrovascular/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Anciano , Anciano de 80 o más Años , Teorema de Bayes , Isquemia Encefálica/terapia , Arterias Cerebrales/diagnóstico por imagen , Infarto Cerebral/diagnóstico por imagen , Circulación Cerebrovascular , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Accidente Cerebrovascular/terapia , Trombectomía , Resultado del Tratamiento
6.
AJNR Am J Neuroradiol ; 39(6): 1039-1046, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-29674411

RESUMEN

BACKGROUND AND PURPOSE: Early and accurate identification of tumor progression in patients with low-grade gliomas is challenging. We aimed to assess the role of quantitative ADC analysis in the sequential follow-up of patients with low-grade gliomas as a potential imaging marker of tumor stability or progression. MATERIALS AND METHODS: In this retrospective study, patients with a diagnosis of low-grade glioma with at least 12 months of imaging follow-up were retrospectively reviewed. Two neuroradiologists independently reviewed sequential MR imaging in each patient to determine tumor progression using the Response Assessment in Neuro-Oncology criteria. Normalized mean ADC (ADCmean) and 10th percentile ADC (ADC10) values from FLAIR hyperintense tumor volume were calculated for each MR image and compared between patients with stable disease versus tumor progression using univariate analysis. The interval change of ADC values between sequential scans was used to differentiate stable disease from progression using the Fisher exact test. RESULTS: Twenty-eight of 69 patients who were evaluated met our inclusion criteria. Fifteen patients were classified as stable versus 13 patients as having progression based on consensus reads of MRIs and the Response Assessment in Neuro-Oncology criteria. The interval change of ADC values showed greater concordance with ultimate lesion disposition than quantitative ADC values at a single time point. The interval change in ADC10 matched the expected pattern in 12/13 patients with tumor progression (overall diagnostic accuracy of 86%, P <.001). On average, the ADC10 interval change predicted progression 8 months before conventional MR imaging. CONCLUSIONS: The interval change of ADC10 values can be used to identify progression versus stability of low-grade gliomas with a diagnostic accuracy of 86% and before apparent radiologic progression on conventional MR imaging.


Asunto(s)
Neoplasias Encefálicas/diagnóstico por imagen , Neoplasias Encefálicas/patología , Imagen de Difusión por Resonancia Magnética/métodos , Glioma/diagnóstico por imagen , Glioma/patología , Adulto , Anciano , Progresión de la Enfermedad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
7.
AJNR Am J Neuroradiol ; 35(7): 1281-7, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24557704

RESUMEN

BACKGROUND AND PURPOSE: Patients in the neurosurgical intensive care unit undergo multiple head CT scans, resulting in high cumulative radiation exposures. Our aim was to assess the acceptability of a dedicated, special-purpose sinogram-affirmed iterative reconstruction-based ultra-low-dose CT protocol for neurosurgical intensive care unit surveillance head CT examinations, comparing image quality with studies performed with our standard-of-care sinogram-affirmed iterative reconstruction low-dose CT and legacy filtered back-projection standard-dose CT protocols. MATERIAL AND METHODS: A retrospective analysis was performed of 54 head CT examinations: ultra-low-dose CT (n = 22), low-dose CT (n = 12), and standard-dose CT (n = 20) in 22 patients in the neurosurgical intensive care unit. Standard-dose CT was reconstructed by using filtered back-projection on a Somatom Sensation 64 scanner. Ultra-low-dose CT and ultra-low-dose CT examinations were performed on a Siemens AS+128 scanner with commercially available sinogram-affirmed iterative reconstruction. Qualitative and quantitative parameters, including image quality and dose, were evaluated. RESULTS: Sinogram-affirmed iterative reconstruction ultra-low-dose CT represented a 68% lower dose index volume compared with filtered back-projection standard-dose CT techniques in the same patients while maintaining similar quality and SNR levels. Sinogram-affirmed iterative reconstruction low-dose CT offered higher image quality than filtered back-projection standard-dose CT (P < .05) with no differences in SNR at a 24% lower dose index volume. Compared with low-dose CT, ultra-low-dose CT had significantly lower SNR (P = .001) but demonstrated clinically satisfactory measures of image quality. CONCLUSIONS: In this cohort of patients in the neurosurgical intensive care unit, dedicated ultra-low-dose CT for surveillance head CT imaging led to a significant dose reduction while maintaining adequate image quality.


Asunto(s)
Encéfalo/diagnóstico por imagen , Dosis de Radiación , Protección Radiológica/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Cirugía Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Estudios de Factibilidad , Femenino , Humanos , Unidades de Cuidados Intensivos , Masculino , Persona de Mediana Edad , Neurocirugia , Variaciones Dependientes del Observador , Traumatismos por Radiación/etiología , Traumatismos por Radiación/prevención & control , Radiometría , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad , Cirugía Asistida por Computador/efectos adversos , Tomografía Computarizada por Rayos X/efectos adversos
8.
AJNR Am J Neuroradiol ; 35(11): 2045-51, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25034777

RESUMEN

BACKGROUND AND PURPOSE: Despite common use of CTP to assess cerebral hemodynamics in the setting of ischemia, concerns over radiation exposure remain. Our aim was to evaluate the efficacy of an adaptive 70-kVp (peak) whole-brain CTP protocol with variable sampling intervals and extended duration against an established fixed-sampling, limited-period protocol at 80 kVp. MATERIALS AND METHODS: A retrospective analysis of 37 patients with stroke scanned with conventional (n = 17) and variant-protocol (n = 20) whole-brain CTP was performed. We compared radiation dose, parametric map quality, and consistency of full-contrast circulation capture between a modified 70-kVp protocol, with 20 whole-brain passes at variable sampling intervals over an extended sampling period, and a conventional 80-kVp CTP examination with 24 passes at fixed-sampling intervals and a more limited scanning window. Mann-Whitney U test analysis was used to compare both protocols. RESULTS: The 70-kVp CTP scan provided superior image quality at a 45% lower CT dose index volume and 13% lower dose-length product/effective dose compared with the conventional 80-kVp scan. With respect to the consistency of contrast-passage capture, 95% of the adaptive, extended protocol continued through the venous return to baseline, compared with only 47% by using the conventional limited-length protocol. Rapid sampling during the critical arterial arrival and washout period was accomplished in nearly 95% with both the variable and fixed-sampling-interval protocols. CONCLUSIONS: Seventy-kilovolt (peak) CTP with variable and extended sampling produces improved image quality at lower radiation doses with greater consistency of full contrast passage capture.


Asunto(s)
Tomografía Computarizada de Haz Cónico/métodos , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Accidente Cerebrovascular/diagnóstico por imagen , Anciano , Encéfalo/irrigación sanguínea , Encéfalo/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Imagen de Perfusión , Fantasmas de Imagen , Estudios Retrospectivos
9.
AJNR Am J Neuroradiol ; 35(12): 2243-7, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25034779

RESUMEN

BACKGROUND AND PURPOSE: CT-guided biopsy is the most commonly used method to obtain tissue for diagnosis in suspected cases of malignancy involving the spine. The purpose of this study was to demonstrate that a low-dose CT-guided spine biopsy protocol is as effective in tissue sampling as a regular-dose protocol, without adversely affecting procedural time or complication rates. MATERIALS AND METHODS: We retrospectively reviewed all patients who underwent CT-guided spine procedures at our institution between May 2010 and October 2013. Biopsy duration, total number of scans, total volume CT dose index, total dose-length product, and diagnostic tissue yield of low-dose and regular-dose groups were compared. RESULTS: Sixty-four patients were included, of whom 31 underwent low-dose and 33 regular-dose spine biopsies. There was a statistically significant difference in total volume CT dose index and total dose-length product between the low-dose and regular-dose groups (P < .0001). There was no significant difference in the total number of scans obtained (P = .3385), duration of procedure (P = .149), or diagnostic tissue yield (P = .6017). CONCLUSIONS: Use of a low-dose CT-guided spine biopsy protocol is a practical alternative to regular-dose approaches, maintaining overall quality and efficiency at reduced ionizing radiation dose.


Asunto(s)
Biopsia Guiada por Imagen/métodos , Dosis de Radiación , Enfermedades de la Columna Vertebral/cirugía , Tomografía Computarizada por Rayos X/métodos , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Columna Vertebral
10.
AJNR Am J Neuroradiol ; 30(4): 813-4, 2009 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-18854437

RESUMEN

We report a case of a 79-year-old woman with long-standing achalasia that resulted in respiratory stridor and dyspnea. She was evaluated for tracheal compression with use of CT on inspiration and expiration. Airway obstruction and acute respiratory distress secondary to achalasia have been reported in the clinical literature. The importance of recognizing these rare manifestations is crucial for the appropriate treatment of these patients. In this patient, the CT evaluation of tracheal compression provided useful information on the degree of narrowing caused by the dilated esophagus.


Asunto(s)
Acalasia del Esófago/complicaciones , Acalasia del Esófago/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Estenosis Traqueal/diagnóstico por imagen , Estenosis Traqueal/etiología , Anciano , Disnea/etiología , Femenino , Humanos , Ruidos Respiratorios/etiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA