Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
J Card Surg ; 34(6): 453-462, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-31058372

RESUMEN

BACKGROUND: This study explores novel preimplantation risk factors associated with gastrointestinal bleeding (GIB) after continuous-flow left ventricular assist device (CF-LVAD) implantation. CF-LVAD therapy implantation for patients with advanced heart failure is associated with a 20% to 40% incidence of GIB. METHODS: This study includes patients receiving CF-LVAD at a quaternary medical center from 2006 to 2014 (n = 254). The primary endpoint was GIB within 12 months after implantation; the secondary outcome was 3-year all-cause mortality. The Student t test or the χ2 test compared continuous or categorical variables. Competing risks analysis calculated the cumulative incidence of GIB postimplantation. Cox proportional hazards model was used for univariate/multivariate models predicting GIB. RESULTS: Sixty-four patients had GIB, with incidence rates at 1, 3, and 12 months of 11.8%, 19.3%, and 25.2%, respectively. Endoscopy revealed no identified source of bleeding in 41%; 33% of lesions were localized in the upper gastrointestinal tract, with the bulk (39%) categorized as vascular. Patients with prior gastrointestinal abnormalities (n = 98) had a greater risk of GIB post-CF-LVAD (HR 1.85 [1.11-3.09]; P = 0.02) than those with normal gastrointestinal evaluation results (n = 45) and those without preimplantation gastrointestinal evaluation (n = 111). Baseline blood urea nitrogen, chronic obstructive pulmonary disease, and prior percutaneous coronary intervention were statistically associated with post-CF-LVAD GIB. The presence of GIB within 12 months of CF-LVAD implantation was associated with an increased risk of 3-year all-cause mortality (HR 2.57 [1.57-4.15]; P < 0.01). CONCLUSIONS: First-year GIB is associated with increased mortality post-CF-LVAD. We advocate a closer examination of several GIB risk factors when evaluating CF-LVAD candidates.


Asunto(s)
Hemorragia Gastrointestinal/etiología , Insuficiencia Cardíaca/terapia , Corazón Auxiliar/efectos adversos , Anciano , Nitrógeno de la Urea Sanguínea , Femenino , Hemorragia Gastrointestinal/epidemiología , Insuficiencia Cardíaca/mortalidad , Ventrículos Cardíacos , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea , Enfermedad Pulmonar Obstructiva Crónica , Factores de Riesgo , Factores de Tiempo
2.
Curr Cardiol Rep ; 18(7): 62, 2016 07.
Artículo en Inglés | MEDLINE | ID: mdl-27216842

RESUMEN

The role of left ventricular assist devices (LVAD) in patients with end-stage heart failure is well known, both as a temporary treatment before transplantation and as destination therapy, in a scenario of a relative shortage of donors to satisfy the increasing requests for transplantation. The increased population of LVAD patients needs careful imaging assessment before, during, and after LVAD implantation; echocardiography is the best tool for their evaluation and is considered the diagnostic technique of choice for the assessment before, during, and after device implantation. Although the conventional echocardiographic assessment is quite effective in evaluating the main critical issues, the role of new technologies like three-dimensional echocardiography and myocardial deformation measurements is still not properly clarified. In this review, we aim to provide an overview of the main elements that should be considered in the assessment of these patients, underlining the role that could be played by new techniques to improve the diagnostic and prognostic effectiveness of echocardiography in this setting.


Asunto(s)
Ecocardiografía/tendencias , Insuficiencia Cardíaca/terapia , Corazón Auxiliar , Ecocardiografía/métodos , Ecocardiografía Tridimensional , Falla de Equipo , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/fisiopatología , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Ventrículos Cardíacos/diagnóstico por imagen , Corazón Auxiliar/efectos adversos , Humanos , Atención Perioperativa/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA