Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Catheter Cardiovasc Interv ; 91(3): 435-443, 2018 02 15.
Artículo en Inglés | MEDLINE | ID: mdl-28707379

RESUMEN

BACKGROUND: Pre-clinical results of a novel open-cell, thin strut, durable polymer, laser cut cobalt chromium sirolimus-eluting stent (Angiolite) were promising. Using quantitative optical coherence tomographic (OCT) analyses, we explored the healing characteristics of the Angiolite DES system at 3- and 6-months post implantation. METHODS: A total of 103 patients with de novo coronary lesions underwent percutaneous coronary intervention with the Angiolite DES and were randomized 1:3 into two cohorts for angiographic and OCT follow-up, with 28 and 70 patients returning for 3- or 6-month post-PCI surveillance, respectively. The primary endpoints were the 6-month rates of OCT-derived neointimal proliferation, strut coverage and incomplete strut apposition (ISA), whilst the secondary endpoints were 3-month OCT-derived measures of strut coverage and ISA, as well as 6-month quantitative coronary angiographic-derived measures [late lumen loss (LLL), binary restenosis]. RESULTS: The Angiolite stent was successfully implanted in all patients, without periprocedural complications. At 3- and 6-months follow-up, OCT strut coverage was evident in 86.3% and 83.3% of struts, mean neointimal thickness was 73.7 ± 46.5 µm and 73.9 ± 54.3 µm, mean neo-intimal area obstruction of 5.8% ±10.3% and 4.4% ± 11.3%, and ISA rates were 1.3% ± 7.3% and 1.1% ± 6.2%, respectively. In-stent LLL at 6 months was 0.07 ± 0.37 mm, with a binary in-stent angiographic restenosis rate of 0% without any stent thrombosis, myocardial infarction or cardiovascular death, with 1 patient undergoing ischemia-driven target-lesion revascularization. CONCLUSIONS: At 6 months, the Angiolite DES was safe with high rates of strut coverage, modest degrees of neointimal hyperplasia and very low rates of strut malapposition. These data coupled with the absence of in-stent binary restenosis and a very low 6-month in-stent LLL point towards an efficacious DES. Future studies are required to evaluate its efficacy in broader lesion subsets with longer follow-up.


Asunto(s)
Enfermedad de la Arteria Coronaria/cirugía , Vasos Coronarios/cirugía , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea/instrumentación , Tomografía de Coherencia Óptica , Anciano , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/etiología , Vasos Coronarios/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Neointima , Intervención Coronaria Percutánea/efectos adversos , Valor Predictivo de las Pruebas , Diseño de Prótesis , Factores de Tiempo , Resultado del Tratamiento
2.
J Invasive Cardiol ; 32(8): 283-288, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32737263

RESUMEN

OBJECTIVES: The crossover balloon occlusion technique (CBOT) facilitates primary access hemostasis in patients undergoing transfemoral transcatheter aortic valve replacement (TAVR). The CBOT is usually performed through the contralateral femoral artery. The aim of this study was to evaluate, in patients undergoing TAVR, the safety and feasibility of transradial CBOT using the new Oceanus balloon dilatation catheter (iVascular). METHODS: This multicenter study included 104 patients (mean age, 81 ± 7 years; 43% women) undergoing transfemoral TAVR. A modified CBOT through the radial artery was performed in all patients with the Oceanus balloon catheter. Data regarding transradial CBOT, balloon performance, vascular complications, and 30-day clinical events were recorded. RESULTS: Up to 21% of patients had a height >170 cm and 17% presented with severe aortic/iliofemoral tortuosity. The transradial CBOT (left radial 74%, right radial 26%) was performed using either the 140 cm Oceanus (37.5%) or the 200 cm Oceanus (62.5%) balloon catheter. The balloon reached the femoral artery in all patients, and balloon inflation achieved an appropriate vessel closure in 98%. There were no complications related to the balloon catheter, and only 1 patient (1.0%) suffered a minor vascular complication related to the secondary radial access. The 30-day rates of primary access major vascular complications and death were 3.8% and 1.9%, respectively. CONCLUSION: In patients undergoing transfemoral TAVR, transradial CBOT with the Oceanus balloon dilatation catheter was feasible and safe. A balloon length up to 200 cm allowed the use of this technique (from right or left radial access) in all patients regardless of patient height or the presence of a challenging vascular anatomy.


Asunto(s)
Estenosis de la Válvula Aórtica , Oclusión con Balón , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Femenino , Arteria Femoral/cirugía , Hemostasis , Humanos , Masculino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
3.
Coron Artery Dis ; 29(6): 477-481, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-29621009

RESUMEN

BACKGROUND: Paclitaxel-coated balloon (PCB) coronary angioplasty is an alternative treatment for de-novo coronary lesions in small vessels. This study with the new Essential PCB aimed to evaluate early and mid-term clinical outcomes following angioplasty with the Essential PCB in the treatment of de-novo lesions in small vessels. PATIENTS AND METHODS: We included all patients who underwent PCB angioplasty for treating de-novo coronary lesions in small vessels (reference diameter <2.5 mm) between October 2015 and June 2016 in 2 centres. The primary endpoint was the 12-month target lesion failure (TLF) rate: a composite of cardiac death, target vessel-related myocardial infarction, and target lesion revascularization. The secondary endpoints were rates of target vessel failure and global major adverse cardiac events (MACE). RESULTS: A total of 71 patients (comprising 71 lesions) were included, with a mean age of 66±11 years. A 56% were diabetic and 70% had an acute coronary syndrome as an indication for coronary revascularization. The mean vessel diameter and lesion length were 2.21±0.41 and 20.7±9.2 mm, respectively. Predilatation was performed in 85.9% of patients. The median diameter, length, and inflation pressure of the Essential balloon were 2.0 [interquartile range (IQR): 2.0-2.5] mm, 20 (IQR: 15-30) mm, and 12±2 atmospheres, respectively. Angiographic success was achieved in 97.2% of cases, and bail-out stenting was required in nine (12.7%) cases. The incidence of TLF at the 12-month follow-up was 4.2%, with a target lesion revascularization rate of 4.2%. Target vessel failure and global MACE rates were 4.2 and 9.9%, respectively. CONCLUSION: Use of the Essential PCB for treating de-novo coronary lesions in small vessels was safe, with low TLF and MACE rates at the 12-month follow-up.


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Catéteres Cardíacos , Fármacos Cardiovasculares/administración & dosificación , Materiales Biocompatibles Revestidos , Enfermedad de la Arteria Coronaria/terapia , Paclitaxel/administración & dosificación , Anciano , Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/mortalidad , Fármacos Cardiovasculares/efectos adversos , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Paclitaxel/efectos adversos , Quebec , Factores de Riesgo , España , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA