Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Thorax ; 76(9): 930-938, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-33888576

RESUMEN

RATIONALE: Approximately 60% of the patients with obstructive sleep apnoea suffer from a positional effect, and approximately 25% of these patients present events only in the supine position. OBJECTIVE: To validate a new positional vibrating device and evaluate its efficacy in reducing the Apnoea-Hypopnoea Index and the total sleep time in the supine position without disturbing sleep. METHODS: A total of 128 patients were recruited for this multicentre, prospective, parallel, randomised controlled trial and were distributed in three arms (general recommendations, inactive and active device). Full overnight polysomnography was performed at baseline and at 12 weeks. Anthropometric variables and sleep and quality of life questionnaires were collected at 4, 8 and 12 weeks. RESULTS: The Apnoea-Hypopnoea Index decreased from 30.6 per hour to 20.4 per hour (p<0.001) in the active device (AD) group. In this group the reduction was 2.3-fold and 3.3-fold than the ones in the general recommendations (GR) and inactive device (ID) groups, respectively (p=0.014). Sleep time in supine position decreased 17.7%±26.3% in GR group (p<0.001), 13.0%±22.4% with ID group (p<0.001) and 21.0%±25.6% in the AD group (p<0.001). Furthermore, total sleep time increased significantly only in the AD group (22.1±57.5 min, p=0.016), with an increased percentage of time in the N3 (deep sleep) and N3+REM (rapid eye movement) stages, without sleep fragmentation. CONCLUSION: The device was effective in reducing the Apnoea-Hypopnoea Index and time spent in the supine position also in improving sleep architecture. Therefore, the device could be a good option for the management of patients with positional obstructive sleep apnoea. TRIAL REGISTRATION DETAILS: The trial was registered at www.clinicaltrials.gov (NCT03336515).


Asunto(s)
Equipos y Suministros , Apnea Obstructiva del Sueño/fisiopatología , Vibración/uso terapéutico , Diseño de Equipo , Frente , Humanos , Persona de Mediana Edad , Polisomnografía , Estudios Prospectivos , Calidad de Vida , España , Posición Supina , Encuestas y Cuestionarios
2.
Respirology ; 22(2): 378-385, 2017 02.
Artículo en Inglés | MEDLINE | ID: mdl-27623414

RESUMEN

BACKGROUND AND OBJECTIVE: Obstructive sleep apnoea is a prevalent and considerably underdiagnosed disease. The development of cost-effective, home-based, automatic diagnostic devices to improve the diagnosis accessibility is therefore essential. METHODS: In this study, a new portable polygraph (BTI-APNiA) was used to validate automatic scoring. This five-channel device records respiratory flow, oxygen saturation, heart rate, body position and snoring. The validation was performed in two phases. In the first phase, manual and automatic scorings of a new respiratory polygraphy (RP) device (BTI-APNiA) were compared. In the second phase, automatic analysis performed with BTI-APNiA was compared with manual scoring of a validated RP device (Embletta Gold). RESULTS: Phase I was completed by 424 patients (50.5% males, 52.2 ± 12.4 years, BMI of 25.4 ± 4.8 kg/m2 and Epworth Sleepiness Scale score of 8.0 ± 4.0). Manual and automatic analysis resulted in an apnoea-hypopnoea index (AHI) of 13.7 ± 12.7 and 14.0 ± 12.5 (P > 0.05), respectively. The interclass correlation coefficient (ICC) was 0.99 (P < 0.001). During Phase II, 28 patients were evaluated (72.0% men, 49.1 ± 10.9 years, BMI of 27.1 ± 4.2 kg/m2 and Epworth Sleepiness Scale score of 7.5 ± 4.2). Manual analysis of Embletta Gold recordings indicated an AHI of 12.3 ± 14.0, while automatic analysis of the BTI-APNiA was 13.4 ± 14.7 (P > 0.05). The ICC was 0.68 (P < 0.01). CONCLUSION: The automatic analysis of the BTI-APNiA is as accurate as manual analysis of AHI. This automatic analysis compared well with the manual analysis of a validated RP device (Embletta Gold).


Asunto(s)
Polisomnografía , Apnea Obstructiva del Sueño , Adulto , Anciano , Diagnóstico por Computador , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Aplicaciones Móviles , Consumo de Oxígeno , Sistemas de Atención de Punto , Polisomnografía/instrumentación , Polisomnografía/métodos , Reproducibilidad de los Resultados , Apnea Obstructiva del Sueño/diagnóstico , Apnea Obstructiva del Sueño/fisiopatología , España
3.
BMJ Open Respir Res ; 10(1)2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37349132

RESUMEN

BACKGROUND: The influence of body position in obstructive sleep apnoea patients is well known. A positional therapy device placed at the forehead has proven to be effective in reducing the severity of positional obstructive sleep apnoea (POSA) symptoms. The aim of the study was to evaluate patients' therapy compliance and satisfaction in the short term and mid-term. METHODS: A post hoc analysis of a randomised controlled trial was conducted using an inactive device (ID) or an active device (AD) for 3 months. The primary outcomes were device usage and the percentage of patients with good compliance (defined as device use for more than 4 hours per night and more than 70% of nights per week). Secondary outcomes included time spent with head in the supine position, patient satisfaction and side effects. RESULTS: The median duration of using the device was 6.9 hours in the ID group and 6.7 hours in the AD group (p=0.309), and the durations were similar throughout the follow-up period and from the first day of use. The percentage of patients with good compliance was similar and greater than 60% in both groups. The median time spent with head in the supine position was significantly lower in the AD group (2.9%) than in the ID group (12.4%) since the first day of treatment. Both groups showed satisfaction scores values above 8.5 (out of 10) in all items, while side effects were scarcely reported. CONCLUSION: High device compliance was achieved in POSA patients, both in terms of device usage time and percentage of days used. Patients were highly satisfied, and the device effectively reduced the time spent with the head in the supine position from the first day of use.


Asunto(s)
Frente , Apnea Obstructiva del Sueño , Humanos , Polisomnografía , Satisfacción del Paciente , Apnea Obstructiva del Sueño/diagnóstico , Cooperación del Paciente , Satisfacción Personal
4.
Respir Med ; 151: 111-117, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-31047106

RESUMEN

BACKGROUND: Approximately 60% of obstructive sleep apnea (OSA) diagnoses are position-dependent, and avoidance of the supine position could represent an effective treatment. Nevertheless, the majority of the available anti-supine treatments result in discomfort and low adherence. This study evaluated the effectiveness of a new vibrating supine avoidance device in reducing time spent in the supine position and the apnea-hypopnea index (AHI) without affecting sleep structure. Furthermore, the tolerability and satisfaction were also scored. METHODS: Observational prospective study of patients suffering from positional OSA. They were treated with a vibrating device and followed up at the first and fourth weeks after starting the treatment, and further polysomnographic studies were conducted while patients' wore the device. The comparison of the results was carried out through non-parametric tests. Significance level was 5%. RESULTS: Twelve patients had complete data. The device reduced time spent in the supine position (from 51.5 ±â€¯14.8% to 25.2 ±â€¯21.0%, p = 0.005), median AHI (from 30.7 (23.2-38.2) at baseline to 21.5 (12.4-24.3) at the fourth week, p = 0.002). Also an improvement in the minimum SaO2 (from 82.2 ±â€¯7.5 to 87.2 ±â€¯3.6 at the 4th week) was also observed. No variations in sleep quality or quantity were identified. All patients evaluated the device positively. CONCLUSION: Our device was effective in reducing the time spent in the supine position and improving AHI, SaO2 variables and sleep architecture. The device was well tolerated by the patients.


Asunto(s)
Alarmas Clínicas , Monitoreo Fisiológico/instrumentación , Posicionamiento del Paciente/instrumentación , Apnea Obstructiva del Sueño/terapia , Posición Supina/fisiología , Vibración , Femenino , Humanos , Masculino , Persona de Mediana Edad , Oxígeno/sangre , Proyectos Piloto , Polisomnografía , Estudios Prospectivos , Apnea Obstructiva del Sueño/fisiopatología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA