Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 62
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Ann Vasc Surg ; 2024 Aug 03.
Artículo en Inglés | MEDLINE | ID: mdl-39098727

RESUMEN

BACKGROUND: To quantify the volumetric aortic remodeling of patients with acute type B aortic dissection treated with the stent-assisted balloon-induced intimal disruption and relamination (STABILISE) technique. METHODS: All patients with acute type B aortic dissection operated with the STABILISE technique between 2014 and 2017 with preoperative, postoperative, and >12 months (follow-up) computed tomography scans were included in this study. True lumen and total aortic volume were accurately assessed in the thoracic and abdominal portions with a semiautomatic three-dimensional tool. Associations with long-term adverse events were estimated. RESULTS: Seventeen patients were measured at preoperative, postoperative, and a mean follow-up of 19 ± 8 months. The false lumen to total volume ratio decreased on average from 63% to 18% after STABILISE (P < 0.001) and remained around 12% at follow-up. These remodeling was more pronounced in the thoracic aorta (7%) than in the abdominal aorta (28%). The trend in aortic size growth was stronger for volumes than for maximum areas or diameters (P < 0.001, P < 0.05, and P < 0.05, respectively). Adverse events were identified in 4 patients during a long-term follow-up of 76 ± 18 months. The only aortic size variable assessed preoperatively that was associated with undesirable events was the total volume of the abdominal aorta (P < 0.05). CONCLUSIONS: A volumetric analysis of dissected aortic size after the STABILISE procedure allowed accurate quantification of mid-term aortic remodeling and helped to identify the abdominal aortic volume as a preoperative variable associated with undesirable long-term events.

2.
Ann Vasc Surg ; 104: 258-267, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38593921

RESUMEN

BACKGROUD: The learning curve and midterm results of aortoiliac occlusive disease (AIOD) revascularization by robot-assisted laparoscopic (RAL) surgery may be known. METHODS: A prospective single-center study was conducted in the vascular surgery department of Georges Pompidou European Hospital (Paris, France). Patients with AIOD treated by RAL from February 2014 to February 2019 were included. Demographic characteristics, past medical history, Trans-Atlantic Inter-Society Consensus (TASC) lesions classifications, mortality, primary and secondary patency, as well as complication rates were collected. Safety was analyzed by the cumulative sum control chart method with a conversion rate of 10%, operative time by cumulative average-time model, and primary and secondary patency by the Kaplan-Meier method. RESULTS: Seventy patients were included, 18 (25.7%) with TASC C lesions and 52 (74.3%) with TASC D lesions. Before discharge, 14 (24.3%) patients had surgical complications. Among them, 10 (14.3%) required at least one reintervention. One (1.4%) patient died during the hospitalization. The learning curve in terms of safety (conversion rate) was 13 cases with an operating time of 220 minutes after 35 patients. During follow-up (median 37 months [21; 49]), 63 patients (91.3%) improved their symptoms, 53 (76.8%) became asymptomatic, and 3 graft limb occlusions occurred. The primary patency at 12, 24, 36, and 48 months was 94%, 92%, 92%, and 92%, respectively, while the secondary patency for the same intervals was 100%, 98.1%, 98.1%, and 98.1%, respectively. CONCLUSIONS: Robotic surgery in AIOD revascularization seems safe and effective; allowing to treat patients with few comorbidities and severe lesions, in a dedicated center experienced in RAL, with excellent patency. Prospective clinical trials should be performed to confirm safety.


Asunto(s)
Enfermedades de la Aorta , Arteriopatías Oclusivas , Arteria Ilíaca , Curva de Aprendizaje , Procedimientos Quirúrgicos Robotizados , Grado de Desobstrucción Vascular , Humanos , Masculino , Femenino , Procedimientos Quirúrgicos Robotizados/efectos adversos , Arteria Ilíaca/cirugía , Arteria Ilíaca/fisiopatología , Arteria Ilíaca/diagnóstico por imagen , Anciano , Enfermedades de la Aorta/cirugía , Enfermedades de la Aorta/diagnóstico por imagen , Enfermedades de la Aorta/mortalidad , Enfermedades de la Aorta/fisiopatología , Factores de Tiempo , Resultado del Tratamiento , Persona de Mediana Edad , Arteriopatías Oclusivas/cirugía , Arteriopatías Oclusivas/fisiopatología , Arteriopatías Oclusivas/diagnóstico por imagen , Arteriopatías Oclusivas/mortalidad , Estudios Prospectivos , Factores de Riesgo , Complicaciones Posoperatorias/etiología , Laparoscopía/efectos adversos , Paris , Competencia Clínica , Tempo Operativo
3.
Ann Vasc Surg ; 99: 290-297, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37858671

RESUMEN

BACKGROUND: The management of residual aortic dissection after initial type A repair with the Frozen elephant trunk technique remains mostly unexplored. This work aimed to evaluate endovascular second-stage surgery for patients with residual aortic dissection. METHODS: A retrospective analysis of consecutive patients that underwent Type A aortic repair with Frozen elephant trunk, followed by a second-stage endovascular procedure was done from March 2016 to December 2021. The primary outcome was aortic-related adverse events or mortality, and secondary outcomes were aortic remodeling and perioperative complications. Remodeling was assessed by comparing the difference in ratios for true lumen/total aortic diameters on pre-operative and follow-up scans. RESULTS: Thirty-four patients underwent second-stage surgery after Type A repair during the study period (7 thoracic endovascular aortic repair extensions, 1 STABLE/PETTICOAT, and 26 STABILISE). Median follow-up was 23 months (range 2-66 months). There were no perioperative deaths or major complications and 1 reoperation for left subclavian re-embolization. At the last follow-up, there was no aortic-related mortality. There were 5 aortic-related adverse events, including another subclavian re-embolization and a preplanned open conversion. Risk factors were connective tissue disorders (P = 0.01) and aortic aneurysms >55 mm (P = 0.03). Distal remodeling reached statistical significance in all segments (P < 0.01) and was greater for patients treated with the STABILISE technique when compared to extended thoracic endovascular aortic repair (P = 0.01). CONCLUSIONS: Second-stage endovascular management of residual aortic dissection after initial Frozen elephant trunk repair showed excellent perioperative and good midterm outcomes and induced significant remodeling of the entire aorta in most cases, particularly with the STABILISE procedure.


Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/cirugía , Reparación Endovascular de Aneurismas , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/etiología , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/métodos , Estudios Retrospectivos , Resultado del Tratamiento , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/cirugía , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/métodos , Prótesis Vascular , Stents
4.
J Vasc Interv Radiol ; 34(3): 445-453, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36400121

RESUMEN

PURPOSE: To characterize remodeling of conservatively treated isolated mesenteric artery dissection (IMAD) using 3-dimensional (3D) volumetric analysis. MATERIAL AND METHODS: Patients with Type I/II (classification of Yun) treated by conservative therapy between January 2018 and January 2020 were prospectively included. Semiautomatic morphological analysis of the superior mesenteric artery (SMA) included volumetric measurements of the true lumen (TL), false lumen (FL), and overall lumen (OL) and 3D aortomesenteric angles from computed tomography angiography data at admission (T0), 1 month (T1), and 12 months (T12). The SMA morphology of patients with IMAD (n = 15, mean age 53 years ± 7; 87% men) was also compared with that of control individuals (n = 51, mean age 56 years ± 4; 94% men). RESULTS: A significant reduction in OL volume was observed (P <.001), whereas TL volume remained stable (P =.23). The TL/OL volume ratio significantly increased over time (P =.001) from 53% at T1 to 78% at T12. Aortomesenteric 3D angles at 2, 4, and 6 cm from the ostium showed a progressive decrease toward values observed in the control group (P =.013, P =.002, and P =.027, respectively). At T12, 5 patients (33%) had complete remodeling, and aneurysmal change was observed in 2 patients (<20 mm). Smoking and SMA angle at a distance of 6 cm from the ostium (T0) were the only factors affecting remodeling negatively at T12. CONCLUSIONS: One-year remodeling in IMAD followed an overall decrease in OL volume related to a decrease in FL volume. Smokers and patients with larger SMA angles at baseline showed poorer remodeling. Spontaneous arterial remodeling in IMAD might favor conservative therapy.


Asunto(s)
Disección Aórtica , Procedimientos Endovasculares , Masculino , Humanos , Persona de Mediana Edad , Femenino , Tratamiento Conservador , Estudios Retrospectivos , Resultado del Tratamiento , Arterias Mesentéricas , Arteria Mesentérica Superior
5.
Eur J Vasc Endovasc Surg ; 64(6): 656-664, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36075544

RESUMEN

OBJECTIVE: This study aimed to report outcomes of patients with symptomatic acute isolated mesenteric artery dissection (IMAD) treated within a French intestinal stroke centre (ISC). METHODS: All patients with symptomatic IMAD referred to the ISC from January 2016 to January 2020 were included prospectively. Patients with aortic dissection and asymptomatic IMAD were not included. The standardised medical protocol included anticoagulation and antiplatelet therapy, gastrointestinal resting, and oral antibiotics. Operations were considered for acute mesenteric ischaemia (AMI). RESULTS: Among the 453 patients admitted to an ISC during the study period, 34 (median age, 53 years [41 - 67]; 82% men) with acute symptomatic IMAD were included. According to the classification of Yun et al., IMADs were reported as follows: type I (n = 7, 20%), type IIa (n = 6, 18%), type IIb (n = 15, 44%), and type III (i.e., complete superior mesenteric artery [SMA] occlusion; n = 6, 18%). Overall, nine (26%) patients had AMI (type I/II, n = 3; type III, n = 6). On initial computerised tomography angiogram, nine (26%) patients had an associated visceral arterial dissection or pseudoaneurysm. All patients with types I/II (n = 28, 82%) followed a favourable clinical course with conservative therapy, with no need for any operation. All patients with type III (n = 6, 18%) underwent urgent laparotomy with SMA revascularisation (open, n = 4; stenting, n = 1) and or bowel resection (early, n = 3; late, n = 1). Rates of intestinal resection and short bowel syndrome were 12% and 8.8%, respectively. After a median follow up of 26 months [18 - 42], recurrence of symptoms occurred in four (12%) patients and aneurysmal change in 14 (41%), with no re-intervention. CONCLUSION: Although IMAD was associated with a high frequency of AMI, a standardised protocol produced a low rate of intestinal resection. Conservative therapy seems appropriate in types I/II patients, whereas urgent SMA revascularisation should aim to avoid intestinal resection or death in type III patients.


Asunto(s)
Disección Aórtica , Procedimientos Endovasculares , Isquemia Mesentérica , Accidente Cerebrovascular , Masculino , Humanos , Persona de Mediana Edad , Femenino , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/métodos , Resultado del Tratamiento , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/cirugía , Arteria Mesentérica Superior/diagnóstico por imagen , Arteria Mesentérica Superior/cirugía , Isquemia Mesentérica/diagnóstico por imagen , Isquemia Mesentérica/etiología , Isquemia Mesentérica/cirugía , Arterias Mesentéricas , Accidente Cerebrovascular/etiología , Estudios Retrospectivos
6.
Ann Vasc Surg ; 86: 35-42, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35780947

RESUMEN

BACKGROUND: COVID-19 infection is associated not only with venous thromboses but also with arterial thromboses (COV-ATs) in relation with an endothelial dysfunction, a coagulopathy and rhythm disorders. The incidence, the topography, and the prognosis of COV-ATs remain poorly known. The objective of this study was to report the overall experience of the Greater Paris University Hospitals (Assistance Publique - Hopitaux de Paris, AP-HP) during the first pandemic wave of COVID-19 infection. METHODS: After approval by the ethics committee, a study using the AP-HP clinical data warehouse was carried out between March and May 2020. Overall, 124,609 patients had a polymerase chain reaction for COVID-19 in our hospitals, of which 25,345 were positive. From 20,710 exploitable stays, patients tested positive for COVID who presented an episode of acute COV-AT (except coronary and intracranial arteries) were selected on the basis of the French medical classification for clinical procedures codes. The data are presented as absolute values with percentages and/or means with standard deviation. RESULTS: Over the studied period, 60 patients (aged 71±14 years, 42 men) presented a COV-AT at the time of their hospitalization, an incidence of 0.2%. The arterial complication occurred 3±7 days after the COVID infection and was inaugural in 30% of the cases (n = 18). The sites of COV-AT were the lower extremities (n = 35%, 58%), the abdominal aorta (n = 10%, 17%), the thoracic aorta (n = 7%, 12%), the upper limbs (n = 7%, 12%), the cerebral arteries (n = 7%, 12%), the digestive arteries (n = 6%, 10%), the renal arteries (n = 2%, 3%), and the ophthalmic artery (n = 1%, 2%). Multiple COV-ATs were observed in 13 patients (22%). At the time of diagnosis, 20 (33%) patients were in intensive care, including six (10%) patients who were intubated. On computed tomography angiography, COVID lesions were classified as moderate and severe in 25 (42%) and 21 (35%) cases, respectively. Revascularization was attempted in 27 patients (45%), by open surgery in 16 cases, using endovascular techniques in 8 cases and with a hybrid approach in three cases. Six patients (22%) required reinterventions. The duration of hospitalization was 12±9 days. Early mortality (in-hospital or at 30 days) was 30% (n = 18). Nine (15%) patients presented severe nonlethal ischemic complications. CONCLUSIONS: Arterial involvement is rare during COVID-19 infection. The aorta and the arteries of the limbs are the privileged sites. The morbi-mortality of these patients is high. Future studies will have to determine if the systematization of anticoagulation therapy decreases the incidence and the severity of the condition.


Asunto(s)
COVID-19 , Trombosis , Masculino , Humanos , SARS-CoV-2 , Resultado del Tratamiento , Trombosis/diagnóstico por imagen , Trombosis/epidemiología , Trombosis/terapia , Arterias
7.
Eur J Vasc Endovasc Surg ; 60(6): 925-931, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32893103

RESUMEN

OBJECTIVE: Radiation dose in mesenteric stenting (MS) remains under evaluated. Yet, MS can lead to high levels of radiation mainly because lateral angulation is needed. The aim of this study was to evaluate the efficacy of an extra low dose protocol (ELDP) to reduce radiation exposure in MS. METHODS: From November 2017 to November 2019, all patients presenting with either acute or chronic atherosclerotic mesenteric ischaemia treated by antegrade MS using either fixed or mobile imaging systems in three university hospitals were included. In November 2018, an ELDP including ≤3 frames/s fluoroscopy and digital subtraction angiography (DSA) was introduced. Prospectively enrolled ELDP patients (Nov 2018-Nov 2019) were compared with retrospectively captured patients (Historical group, Nov 2017-Nov 2018). Radiation data including dose area product (DAP), cumulative air kerma (CAK), and fluoroscopy time (FT) were analysed. RESULTS: Overall, 46 patients (median age 73 years [63-72], 59% males) were included (ELDP group, n = 21; Historical group, n = 25). Thirty-three patients (72%) underwent MS in a hybrid room. Median DAP (ELDP group, 10 [4.7-26] Gy.cm2vs. Historical group, 45 [24-88] Gy.cm2, p = .002), median CAK (ELDP group, 170 [58-260] vs. Historical group, 262 [152-460], p = .037), and median number of DSA runs (ELDP group, 4 [1.5-5] vs. Historical group, 5.5 [3.7-5], p = .030) were statistically significantly lower in patients receiving the ELDP, whereas median FT (ELDP group, 16 min [11-23] vs. Historical group, 14 min [9-25], p = .71) and technical success (ELDP group, 95%; Historical group, 92%, p = .65) were not statistically significantly different between groups. CONCLUSION: MS exposes both patients and physicians to a high ionising radiation dose. Awareness of radiation safety and seeking dose reduction is paramount in these highly irradiating procedures. The use of ELDP significantly reduces radiation without compromising technical success.


Asunto(s)
Personal de Salud , Oclusión Vascular Mesentérica/cirugía , Exposición Profesional/prevención & control , Exposición a la Radiación/prevención & control , Radiografía Intervencional/métodos , Anciano , Angiografía de Substracción Digital , Procedimientos Endovasculares , Femenino , Fluoroscopía , Humanos , Masculino , Arteria Mesentérica Superior , Oclusión Vascular Mesentérica/diagnóstico por imagen , Persona de Mediana Edad , Seguridad del Paciente , Estudios Prospectivos , Implantación de Prótesis , Dosis de Radiación , Stents
8.
Ann Vasc Surg ; 68: 559-562, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32561244

RESUMEN

BACKGROUND: The purpose of this study was to describe the use of the OUTBACK catheter to overcome aortic reentry issues in acute mesenteric ischemia (AMI) treated by retrograde open mesenteric stenting (ROMS). TECHNIQUE: The technique is demonstrated in two female patients presenting with late AMI related to flush occlusion of the superior mesenteric artery (SMA). In such cases of thrombotic AMI with clear preoperative evidence of intestinal necrosis, ROMS is the first-line revascularization technique in our intestinal stroke center. Following an open approach of the SMA through laparotomy, the SMA was punctured in a retrograde fashion. Retrograde mesenteric subintimal recanalization was initiated. In case of aortic reentry issue, the OUTBACK Elite (Cordis, Hialeah, Fl) catheter was advanced through the occlusion over a 0.014 guidewire. The aortic reentry was created by puncture of the aortic wall with the OUTBACK needle, positioned in the desired position. After low-profile balloon angioplasty of the reentry site and 0.035 guidewire exchange, ROMS was performed using balloon-expandable covered stent. CONCLUSIONS: The OUTBACK catheter appears to be a safe and effective tool to overcome aortic reentry issues in ROMS. This technical tip might therefore increase the technical success rate of challenging ROMS and decrease the need for bailout bypass in the septic context of AMI.


Asunto(s)
Angioplastia de Balón/instrumentación , Arteria Mesentérica Superior , Isquemia Mesentérica/terapia , Oclusión Vascular Mesentérica/terapia , Stents , Dispositivos de Acceso Vascular , Anciano , Angioplastia de Balón/efectos adversos , Femenino , Humanos , Arteria Mesentérica Superior/diagnóstico por imagen , Arteria Mesentérica Superior/fisiopatología , Isquemia Mesentérica/diagnóstico por imagen , Isquemia Mesentérica/fisiopatología , Oclusión Vascular Mesentérica/diagnóstico por imagen , Oclusión Vascular Mesentérica/fisiopatología , Diseño de Prótesis , Circulación Esplácnica , Resultado del Tratamiento , Grado de Desobstrucción Vascular
9.
Surg Radiol Anat ; 42(4): 429-435, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31637473

RESUMEN

PURPOSE: During right-sided colectomies, surgeons encounter major anatomical variations at the level of the right colon, leading to morbidity. Due to the confusion surrounding the colonic arterial vessels emerging from the superior mesenteric artery (SMA) to vascularize the right part of the colon, this review aimed to describe the arterial vessels found in the mesocolic structures of the ascending colon, the hepatic flexure and the right transverse colon. METHODS: A review of the literature was performed using the MEDLINE database. Only human studies were included. All dissection, angiographic, arterial cast and corrosion studies were analyzed. RESULTS: This review demonstrates that the right colon, the hepatic flexure and the right transverse colon are vascularized by three significant arteries emerging from the SMA and forming one peripheral paracolic arc: (1) the ileocolic artery (ICA), the most constant vessel (99.8%) with low variability; (2) the right colic artery (RCA), the most inconstant vessel (2/3 of cases) with high variability in its origin; and (3) the middle colic artery (MCA), a constant vessel (95%) with variation in its origin and its number. The marginal artery is almost constant (100%) and represents the only peripheral arterial arc at the level of the right side of the colon. CONCLUSIONS: Three arteries emerging from the superior mesenteric artery exist: the ICA, the RCA and the MCA. The ICA and the MCA are the most constant. Knowledge of this vascular anatomy is essential for performing right-sided colectomies.


Asunto(s)
Colon/irrigación sanguínea , Arteria Mesentérica Superior/anatomía & histología , Colon/cirugía , Humanos
12.
Eur J Vasc Endovasc Surg ; 56(2): 209-215, 2018 08.
Artículo en Inglés | MEDLINE | ID: mdl-29891434

RESUMEN

OBJECTIVES: This article reports mid-term results of 41 patients treated by the stent assisted balloon induced intimal disruption and relamination (STABILISE) technique for acute type B aortic dissection. METHODS: Between November 2011 and November 2017, 41 patients (10 male; median age 50 years) underwent proximal descending aortic stent grafting plus stent assisted balloon induced intimal disruption of the thoraco-abdominal aorta for acute type B aortic dissection. Serial computed tomography angiography was used to assess aortic remodelling. RESULTS: There were no intra-procedural complications. Fifteen branch arteries supplied by the false lumen were stented (9% of the visceral branch arteries). The thirty day incidence of death, stroke, and paralysis/visceral ischaemia was 2% (n = 1), 0%, 5% (n = 2), and 2% (n = 1) respectively. During a median follow up of 12 months (range 1-168) eight patients (20%) required re-intervention. Primary visceral stent patency was 93% (n = 14). No aortic related deaths occurred. On the most recent computed tomography angiogram, complete false lumen obliteration and aortic remodelling was obtained in all patients at the thoraco-abdominal level, and in 39% (n = 16) at the unstented infrarenal aorto-iliac level. The maximum aortic diameter increased in only two patients (5%) at the unstented infrarenal level. CONCLUSION: To obtain immediate and durable thoraco-abdominal aortic remodelling in acute type B dissections, the STABILISE technique is safe and reproducible while not compromising the patency of collateral branches.


Asunto(s)
Angioplastia de Balón/instrumentación , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Torácica/cirugía , Disección Aórtica/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Stents , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/fisiopatología , Angioplastia de Balón/efectos adversos , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/fisiopatología , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/fisiopatología , Aortografía/métodos , Implantación de Prótesis Vascular/efectos adversos , Circulación Colateral , Angiografía por Tomografía Computarizada , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento , Grado de Desobstrucción Vascular , Remodelación Vascular
13.
Eur J Vasc Endovasc Surg ; 56(3): 373-380, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-30005965

RESUMEN

OBJECTIVE/BACKGROUND: To evaluate the experimental feasibility of endovascular fenestration using specific endovascular scissor prototypes in an ovine model of acute aortic dissection (AD). METHODS: A previously described endovascular technique was used to create a model of acute type B AD in sheep. Endovascular fenestrations using either endovascular scissor prototypes or a long sheath were compared. Four prototypes of endovascular fenestration scissors were evaluated. Both validity of the experimental model of AD and technical success of endovascular fenestration were assessed by haemodynamic criteria, completion angiography, transesophageal echocardiography, and post-procedural analysis of harvested aortas. RESULTS: Experimental acute AD was created by endovascular means in 17 sheep, with a technical success rate of 82%. Systolic blood pressure was lower in the false lumen than in the true lumen (58 ± 5 vs. 79 ± 3 mmHg, respectively; p < .001). Endovascular fenestration was performed in 11 models (endovascular scissors n = 8; long sheath n = 3). Controlled endovascular fenestration was obtained by the use of endovascular scissors (n = 5/8), resulting in a significant rise in false lumen systolic blood pressure after fenestration (60 ± 2 vs. 67 ± 9 mmHg before and after fenestration, respectively; p < .047). Long sheath fenestration resulted in an uncontrolled flap motion, leading to either pseudo-coarctation syndrome or aortic rupture (58 ± 6 vs. 40 ± 2 mmHg before and after fenestration, respectively; p < .001). CONCLUSION: In this experimental study, a reproducible AD model has been developed in sheep using endovascular procedures exclusively to evaluate endovascular fenestration techniques. Endovascular fenestration using a long sheath appeared hazardous and risky in vivo. Endovascular scissors constitute a dedicated and suitable tool to perform a safe controlled and effective endovascular fenestration in an ovine model.


Asunto(s)
Aneurisma de la Aorta/cirugía , Disección Aórtica/cirugía , Procedimientos Endovasculares/instrumentación , Instrumentos Quirúrgicos , Disección Aórtica/patología , Disección Aórtica/fisiopatología , Animales , Aneurisma de la Aorta/patología , Aneurisma de la Aorta/fisiopatología , Presión Arterial , Modelos Animales de Enfermedad , Diseño de Equipo , Estudios de Factibilidad , Ensayo de Materiales , Oveja Doméstica
14.
Surg Radiol Anat ; 40(10): 1165-1168, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30128895

RESUMEN

We describe an uncommon association of crossed pulmonary arteries and a right aortic arch with a Kommerell diverticulum and a left ligamentum arteriosum, resulting in disabling dysphagia in a 33-year-old woman. First, endovascular exclusion of the Kommerell diverticulum was performed using a thoracic stent graft, associated with left subclavian-carotid transposition. Second, open aneurysmorrhaphy and division of the left ligamentum arteriosum allowed a proper release of the oesophageal compression. Dysphagia completely disappeared in the postoperative course. Control computed tomography angiography at 6-month follow-up showed a satisfactory hybrid repair. A complete understanding of the combined effects of these two anatomical variations on oesophageal compression led to a suitable surgical management.


Asunto(s)
Aorta Torácica/anomalías , Aneurisma de la Aorta Torácica/complicaciones , Trastornos de Deglución/etiología , Divertículo/complicaciones , Arteria Pulmonar/anomalías , Adulto , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/cirugía , Angiografía por Tomografía Computarizada , Constricción Patológica/diagnóstico por imagen , Constricción Patológica/etiología , Constricción Patológica/cirugía , Trastornos de Deglución/diagnóstico por imagen , Endoscopía del Sistema Digestivo , Esófago/diagnóstico por imagen , Esófago/patología , Femenino , Humanos , Arteria Pulmonar/diagnóstico por imagen , Stents , Procedimientos Quirúrgicos Vasculares/instrumentación , Procedimientos Quirúrgicos Vasculares/métodos
17.
Ann Vasc Surg ; 40: 297.e13-297.e17, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-27903475

RESUMEN

BACKGROUND: Closure of the proximal tear by thoracic endovascular aortic repair (TEVAR) at the acute phase appears to be a safe effective treatment to prevent aneurysmal degeneration type B dissection. However, it appears to be inefficient in up to a third of the patient. We report the technical aspects of our experience with patients undergoing secondary open repair after TEVAR for dissecting thoracoabdominal aneurysm despite early closure proximal tear by TEVAR. METHODS: During a period of 5 years, 96 patients presenting acute type B aortic dissections were treated by TEVAR and followed-up in our institution. Among them, 5 patients experienced an evolution to a dissecting thoracoabdominal aortic aneurysm. Their demographic data and initial medical conditions, delay to reintervention, operative technical details, perioperative and mid-term outcomes were collected and analyzed. RESULTS: All 5 patients (4 male, mean age 58 ± 9) were operated under peripheral normothermic bypass without deep circulatory arrest using the thoracic stent graft as an elephant trunk for completion of the proximal anastomosis. In cases of patency, the false lumen was reapproximated in the anastomosis, 6 visceral arteries were revascularized selectively. One patient died at day 1 of perioperative ventricular fibrillation due to an acute myocardial infarction. The 4 others are alive without complication after a median of 30 months, range (13-22). CONCLUSIONS: In our experience, TEVAR was not only efficient at the acute phase to deal with complications, but in cases of subsequent aneurysmal evolution, it made open repair even easier by avoiding very proximal cross-clamping/anastomosis and circulatory arrest.


Asunto(s)
Aneurisma de la Aorta Torácica/cirugía , Disección Aórtica/cirugía , Implantación de Prótesis Vascular/métodos , Procedimientos Endovasculares/métodos , Anciano , Disección Aórtica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Progresión de la Enfermedad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reoperación , Factores de Tiempo , Resultado del Tratamiento
18.
Ann Vasc Surg ; 40: 298.e1-298.e4, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-27939371

RESUMEN

The aim of this case study is to report a case of unusual manifestation of ruptured abdominal aortic aneurysm (AAA) involving an aortocaval fistula (ACF) as phlegmasia cerulea dolens (PCD). A 58-year-old male presented with acute signs of PCD of the right lower limb, confirmed on duplex ultrasonography. Computed tomography angiography revealed a 65-mm ruptured AAA with a large ACF. Successful emergent surgical repair was performed, using implantation of an aortobi-iliac graft with primary closure of the fistula and associated venous thrombectomy. PCD revealing a ruptured AAA with ACF is rare. Knowledge of this original entity might be the most important factor on the outcome.


Asunto(s)
Aneurisma de la Aorta Abdominal/complicaciones , Rotura de la Aorta/etiología , Fístula Arteriovenosa/etiología , Tromboflebitis/etiología , Vena Cava Inferior , Trombosis de la Vena/etiología , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Rotura de la Aorta/diagnóstico por imagen , Rotura de la Aorta/cirugía , Aortografía/métodos , Fístula Arteriovenosa/diagnóstico por imagen , Fístula Arteriovenosa/cirugía , Implantación de Prótesis Vascular , Angiografía por Tomografía Computarizada , Humanos , Masculino , Persona de Mediana Edad , Flebografía/métodos , Trombectomía , Tromboflebitis/diagnóstico por imagen , Tromboflebitis/cirugía , Resultado del Tratamiento , Ultrasonografía Doppler Dúplex , Vena Cava Inferior/diagnóstico por imagen , Vena Cava Inferior/cirugía , Trombosis de la Vena/diagnóstico por imagen , Trombosis de la Vena/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA