Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Pulm Pharmacol Ther ; 75: 102133, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35644305

RESUMEN

BACKGROUND: Janus Kinases (JAKs) mediate activity of many asthma-relevant cytokines. GDC-0214, an inhaled small molecule JAK1 inhibitor, has previously been shown to reduce fractional exhaled nitric oxide (FeNO) in patients with mild asthma, but required an excessive number of inhalations. AIM: To assess whether GDC-4379, a new inhaled JAK inhibitor, reduces FeNO and peripheral biomarkers of inflammation. METHODS: This study assessed the activity of GDC-4379 in a double-blind, randomized, placebo-controlled, Phase 1 study in patients with mild asthma. Participants included adults (18-65y) with a diagnosis of asthma for ≥6 months, forced expiratory volume in 1 s (FEV1)> 70% predicted, FeNO >40 ppb, using as-needed short-acting beta-agonist medication only. Four sequential, 14-day, ascending-dose cohorts (10 mg QD, 30 mg QD, 40 mg BID, and 80 mg QD) of 12 participants each were randomized 2:1 to GDC-4379 or placebo. The primary activity outcome was percent change from baseline (CFB) in FeNO to Day 14 compared to the pooled placebo group. Safety, tolerability, pharmacokinetics, and pharmacodynamic biomarkers, including blood eosinophils, serum CCL17, and serum CCL18, were also assessed. RESULTS: Of 48 enrolled participants, the mean age was 25 years and 54% were female. Median (range) FeNO at baseline was 79 (41-222) ppb. GDC-4379 treatment led to dose-dependent reductions in FeNO. Compared to placebo, mean (95% CI) percent CFB in FeNO to Day 14 was: -6 (-43, 32) at 10 mg QD, -26 (-53, 2) at 30 mg QD, -55 (-78, -32) at 40 mg BID and -52 (-72, -32) at 80 mg QD. Dose-dependent reductions in blood eosinophils and serum CCL17 were also observed. Higher plasma drug concentrations corresponded with greater FeNO reductions. No serious AEs occurred. The majority of AEs were mild to moderate. The most common AEs were headache and oropharyngeal pain. Minor changes in neutrophils were noted at 80 mg QD, but were not considered clinically meaningful. CONCLUSIONS: In patients with mild asthma, 14-day treatment with GDC-4379 reduced FeNO levels and peripheral biomarkers of inflammation. Treatment was well tolerated without any major safety concerns. AUSTRALIAN NEW ZEALAND CLINICAL TRIALS REGISTRY: ACTRN12619000227190.


Asunto(s)
Asma , Inhibidores de las Cinasas Janus , Adulto , Asma/tratamiento farmacológico , Australia , Biomarcadores , Pruebas Respiratorias , Femenino , Humanos , Inflamación/tratamiento farmacológico , Inhibidores de las Cinasas Janus/efectos adversos , Masculino , Óxido Nítrico
2.
J Allergy Clin Immunol ; 148(3): 783-789, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-33744327

RESUMEN

BACKGROUND: The Janus kinase (JAK) pathway mediates the activity of many asthma-relevant cytokines, including IL-4 and IL-13. GDC-0214 is a potent, inhaled, small-molecule JAK inhibitor being developed for the treatment of asthma. OBJECTIVE: We sought to determine whether GDC-0214 reduces fractional exhaled nitric oxide (Feno), a JAK1-dependent biomarker of airway inflammation, in patients with mild asthma. METHODS: We conducted a double-blind, randomized, placebo-controlled, phase 1 proof-of-activity study in adults with mild asthma and Feno higher than 40 parts per billion (ppb). Subjects were randomized 2:1 (GDC-0214:placebo) into 4 sequential ascending-dose cohorts (1 mg once daily [QD], 4 mg QD, 15 mg QD, or 15 mg twice daily). All subjects received 4 days of blinded placebo, then 10 days of either active drug or placebo. The primary outcome was placebo-corrected percent reduction in Feno from baseline to day 14. Baseline was defined as the average Feno during the blinded placebo period. Pharmacokinetics, safety, and tolerability were also assessed. RESULTS: Thirty-six subjects (mean age, 28 years; 54% females) were enrolled. Mean Feno at baseline across all subjects was 93 ± 43 ppb. At day 14, placebo-corrected difference in Feno was -23% (95% CI, -37.3 to -9) for 15 mg QD and -42% (95% CI, -57 to -27.4) for 15 mg twice daily. Higher plasma exposure was associated with greater Feno reduction. No dose-limiting adverse events, serious adverse events, or treatment discontinuations occurred. There were no major imbalances in adverse events or laboratory findings, or evidence of systemic JAK inhibition. CONCLUSIONS: GDC-0214, an inhaled JAK inhibitor, caused dose-dependent reductions in Feno in mild asthma and was well tolerated without evidence of systemic toxicity.


Asunto(s)
Antiasmáticos/uso terapéutico , Asma/tratamiento farmacológico , Inhibidores de las Cinasas Janus/uso terapéutico , Óxido Nítrico/metabolismo , Adolescente , Adulto , Antiasmáticos/sangre , Antiasmáticos/farmacocinética , Antiasmáticos/farmacología , Asma/metabolismo , Método Doble Ciego , Espiración , Femenino , Humanos , Inhibidores de las Cinasas Janus/sangre , Inhibidores de las Cinasas Janus/farmacocinética , Inhibidores de las Cinasas Janus/farmacología , Masculino , Adulto Joven
3.
Eur J Pharm Sci ; 175: 106226, 2022 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-35643378

RESUMEN

Capsule-based, single-dose dry powder inhalers (DPIs) are commonly-used devices to deliver medications to the lungs. This work evaluates the effect of the drug/excipient adhesive bonding and the DPI resistances on the aerosol performance using a combination of empirical multi-stage impactor data and a fully-coupled computational fluid dynamics (CFD) and discrete element method (DEM) model. Model-predicted quantities show that the primary modes of powder dispersion are a function of the device resistance. Lowering the device resistance increases its capacity to transport a wider range of particle size classes toward the outlet and generate more intense turbulence upstream therein. On the other hand, a higher device resistance increases the velocity of the tangential airflow along the device walls, which in turn increases the intensity of particle/device impaction. Correlating model data and experimental results shows that these differing powder dispersion mechanisms affect different formulations differently, with finer aerosols tending to result when pairing a lower resistance device with formulations that exhibit low API/excipient adhesion, or when pairing a high resistance device with more cohesive formulations.


Asunto(s)
Inhaladores de Polvo Seco , Hidrodinámica , Administración por Inhalación , Aerosoles , Diseño de Equipo , Excipientes , Tamaño de la Partícula , Polvos
4.
Clin Transl Sci ; 15(5): 1225-1237, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35157370

RESUMEN

Several inflammatory cytokines that promote inflammation and pathogenesis in asthma signal through the Janus kinase 1 (JAK1) pathway. This phase I, randomized, placebo-controlled trial assessed the pharmacokinetics and safety of single and multiple ascending doses up to 15 mg twice daily for 14 days of a JAK1 inhibitor, GDC-0214, in healthy volunteers (HVs; n = 66). Doses were administered with a dry powder, capsule-based inhaler. An accompanying open-label gamma scintigraphy study in HVs examined the lung deposition of a single dose of inhaled Technetium-99m (99m Tc)-radiolabeled GDC-0214. GDC-0214 plasma concentrations were linear and approximately dose-proportional after both single and multiple doses. Peak plasma concentrations occurred at 15-30 min after dosing. The mean apparent elimination half-life ranged from 32 to 56 h across all single and multiple dose cohorts. After single and multiple doses, all adverse events were mild or moderate, and none led to treatment withdrawal. There was no clear evidence of systemic toxicity due to JAK1 inhibition, and systemic exposure was low, with plasma concentrations at least 15-fold less than the plasma protein binding-corrected IC50 of JAK1 at the highest dose. Scintigraphy showed that approximately 50% of the emitted dose of radiolabeled GDC-0214 was deposited in the lungs and was distributed well to the peripheral airways. 99m Tc-radiolabeled GDC-0214 (1 mg) exhibited a mean plasma Cmax similar to that observed in phase I at the same dose level. Overall, inhaled GDC-0214 exhibited pharmacokinetic properties favorable for inhaled administration.


Asunto(s)
Pulmón , Área Bajo la Curva , Relación Dosis-Respuesta a Droga , Método Doble Ciego , Voluntarios Sanos , Humanos , Pulmón/diagnóstico por imagen , Cintigrafía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA