Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 271
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Proc Natl Acad Sci U S A ; 121(8): e2303119121, 2024 Feb 20.
Artículo en Inglés | MEDLINE | ID: mdl-38349880

RESUMEN

Coupling red blood cell (RBC) supply to O2 demand is an intricate process requiring O2 sensing, generation of a stimulus, and signal transduction that alters upstream arteriolar tone. Although actively debated, this process has been theorized to be induced by hypoxia and to involve activation of endothelial inwardly rectifying K+ channels (KIR) 2.1 by elevated extracellular K+ to trigger conducted hyperpolarization via connexin40 (Cx40) gap junctions to upstream resistors. This concept was tested in resting healthy skeletal muscle of Cx40-/- and endothelial KIR2.1-/- mice using state-of-the-art live animal imaging where the local tissue O2 environment was manipulated using a custom gas chamber. Second-by-second capillary RBC flow responses were recorded as O2 was altered. A stepwise drop in PO2 at the muscle surface increased RBC supply in capillaries of control animals while elevated O2 elicited the opposite response; capillaries were confirmed to express Cx40. The RBC flow responses were rapid and tightly coupled to O2; computer simulations did not support hypoxia as a driving factor. In contrast, RBC flow responses were significantly diminished in Cx40-/- mice. Endothelial KIR2.1-/- mice, on the other hand, reacted normally to O2 changes, even when the O2 challenge was targeted to a smaller area of tissue with fewer capillaries. Conclusively, microvascular O2 responses depend on coordinated electrical signaling via Cx40 gap junctions, and endothelial KIR2.1 channels do not initiate the event. These findings reconceptualize the paradigm of blood flow regulation in skeletal muscle and how O2 triggers this process in capillaries independent of extracellular K+.


Asunto(s)
Capilares , Oxígeno , Animales , Ratones , Capilares/fisiología , Proteína alfa-5 de Unión Comunicante/metabolismo , Uniones Comunicantes/metabolismo , Hipoxia/metabolismo , Músculo Esquelético/metabolismo , Oxígeno/metabolismo
2.
N Engl J Med ; 389(18): 1660-1671, 2023 Nov 02.
Artículo en Inglés | MEDLINE | ID: mdl-37634148

RESUMEN

BACKGROUND: Catheter-based pulmonary vein isolation is an effective treatment for paroxysmal atrial fibrillation. Pulsed field ablation, which delivers microsecond high-voltage electrical fields, may limit damage to tissues outside the myocardium. The efficacy and safety of pulsed field ablation as compared with conventional thermal ablation are not known. METHODS: In this randomized, single-blind, noninferiority trial, we assigned patients with drug-refractory paroxysmal atrial fibrillation in a 1:1 ratio to undergo pulsed field ablation or conventional radiofrequency or cryoballoon ablation. The primary efficacy end point was freedom from a composite of initial procedural failure, documented atrial tachyarrhythmia after a 3-month blanking period, antiarrhythmic drug use, cardioversion, or repeat ablation. The primary safety end point included acute and chronic device- and procedure-related serious adverse events. RESULTS: A total of 305 patients were assigned to undergo pulsed field ablation, and 302 were assigned to undergo thermal ablation. At 1 year, the primary efficacy end point was met (i.e., no events occurred) in 204 patients (estimated probability, 73.3%) who underwent pulsed field ablation and 194 patients (estimated probability, 71.3%) who underwent thermal ablation (between-group difference, 2.0 percentage points; 95% Bayesian credible interval, -5.2 to 9.2; posterior probability of noninferiority, >0.999). Primary safety end-point events occurred in 6 patients (estimated incidence, 2.1%) who underwent pulsed field ablation and 4 patients (estimated incidence, 1.5%) who underwent thermal ablation (between-group difference, 0.6 percentage points; 95% Bayesian credible interval, -1.5 to 2.8; posterior probability of noninferiority, >0.999). CONCLUSIONS: Among patients with paroxysmal atrial fibrillation receiving a catheter-based therapy, pulsed field ablation was noninferior to conventional thermal ablation with respect to freedom from a composite of initial procedural failure, documented atrial tachyarrhythmia after a 3-month blanking period, antiarrhythmic drug use, cardioversion, or repeat ablation and with respect to device- and procedure-related serious adverse events at 1 year. (Funded by Farapulse-Boston Scientific; ADVENT ClinicalTrials.gov number, NCT04612244.).


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Fibrilación Atrial/clasificación , Fibrilación Atrial/cirugía , Teorema de Bayes , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Venas Pulmonares/cirugía , Recurrencia , Método Simple Ciego , Taquicardia/etiología , Resultado del Tratamiento
3.
Ann Bot ; 134(1): 43-58, 2024 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-38430562

RESUMEN

BACKGROUND AND AIMS: There is growing interest in the functional ecology of poikilohydric non-vascular photoautotrophs (NVPs), including 'cryptogamic' bryophytes and lichens. These organisms are structurally important in many ecosystems, contributing substantially to ecosystem function and services, while also being sensitive to climate change. Previous research has quantified the climate change response of poikilohydric NVPs using predictive bioclimatic models with standard climate variables including precipitation totals and temperature averages. This study aimed for an improved functional understanding of their climate change response based on their growth rate sensitivity to moisture and light. METHODS: We conducted a 24-month experiment to monitor lichen hydration and growth. We accounted for two well-known features in the ecology of poikilohydric NVPs, and exemplified here for a structurally dominant lichen epiphyte, Lobaria pulmonaria: (1) sensitivity to multiple sources of atmospheric moisture including rain, condensed dew-formation and water vapour; and (2) growth determined by the amount of time hydrated in the light, driving photosynthesis, referred to as the Iwet hypothesis. KEY RESULTS: First, we found that even within an oceanic high-rainfall environment, lichen hydration was better explained by vapour pressure deficit than precipitation totals. Second, growth at a monthly resolution was positively related to the amount of time spent hydrated in the light, and negatively related to the amount of time spent hydrated in the dark. CONCLUSIONS: Using multimodel averaging to project growth models for an ensemble of future climate change scenarios, we demonstrated reduced net growth for L. pulmonaria by the late 21st century, explained by extended climate dryness and lichen desiccation for periods when there is otherwise sufficient light to drive photosynthesis. The results further emphasize a key issue of photoperiodism when constructing functionally relevant models to understand the risk of climate change, especially for poikilohydric NVPs.


Asunto(s)
Cambio Climático , Líquenes , Fotosíntesis , Líquenes/fisiología , Líquenes/crecimiento & desarrollo , Líquenes/efectos de la radiación , Fotosíntesis/fisiología , Agua/fisiología , Luz , Ecosistema , Lluvia
4.
JAMA ; 331(13): 1099-1108, 2024 04 02.
Artículo en Inglés | MEDLINE | ID: mdl-38563835

RESUMEN

Importance: Left atrial appendage elimination may improve catheter ablation outcomes for atrial fibrillation. Objective: To assess the safety and effectiveness of percutaneous left atrial appendage ligation adjunctive to catheter pulmonary vein isolation for nonparoxysmal atrial fibrillation. Design, Setting, and Participants: This multicenter, prospective, open-label, randomized clinical trial evaluated the safety and effectiveness of percutaneous left atrial appendage ligation adjunctive to planned pulmonary vein isolation for nonparoxysmal atrial fibrillation present for less than 3 years. Eligible patients were randomized in a 2:1 ratio to undergo left atrial appendage ligation and pulmonary vein isolation or pulmonary vein isolation alone. Use of a 2:1 randomization ratio was intended to provide more device experience and safety data. Patients were enrolled from October 2015 to December 2019 at 53 US sites, with the final follow-up visit on April 21, 2021. Interventions: Left atrial appendage ligation plus pulmonary vein isolation compared with pulmonary vein isolation alone. Main Outcomes and Measures: A bayesian adaptive analysis was used for primary end points. Primary effectiveness was freedom from documented atrial arrythmias of greater than 30 seconds duration 12 months after undergoing pulmonary vein isolation. Rhythm was assessed by Holter monitoring at 6 and 12 months after pulmonary vein isolation, symptomatic event monitoring, or any electrocardiographic tracing obtained through 12 months after pulmonary vein isolation. Primary safety was a composite of predefined serious adverse events compared with a prespecified 10% performance goal 30 days after the procedure. Left atrial appendage closure was evaluated through 12 months after pulmonary vein isolation. Results: Overall, 404 patients were randomized to undergo left atrial appendage ligation plus pulmonary vein isolation and 206 were randomized to undergo pulmonary vein isolation alone. Primary effectiveness was 64.3% with left atrial appendage ligation and pulmonary vein isolation and 59.9% with pulmonary vein isolation only (difference, 4.3% [bayesian 95% credible interval, -4.2% to 13.2%]; posterior superiority probability, 0.835), which did not meet the statistical criterion to establish superiority (0.977). Primary safety was met, with a 30-day serious adverse event rate of 3.4% (bayesian 95% credible interval, 2.0% to 5.0%; posterior probability, 1.0) which was less than the prespecified threshold of 10%. At 12 months after pulmonary vein isolation, complete left atrial appendage closure (0 mm residual communication) was observed in 84% of patients and less than or equal to 5 mm residual communication was observed in 99% of patients. Conclusions and Relevance: Percutaneous left atrial appendage ligation adjunctive to pulmonary vein isolation did not meet prespecified efficacy criteria for freedom from atrial arrhythmias at 12 months compared with pulmonary vein isolation alone for patients with nonparoxysmal atrial fibrillation, but met prespecified safety criteria and demonstrated high rates of closure at 12 months. Trial Registration: ClinicalTrials.gov Identifier: NCT02513797.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Compuestos Organotiofosforados , Venas Pulmonares , Humanos , Apéndice Atrial/cirugía , Fibrilación Atrial/cirugía , Teorema de Bayes , Estudios Prospectivos , Venas Pulmonares/cirugía , Ablación por Catéter , Cateterismo
5.
New Phytol ; 237(5): 1495-1504, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36511294

RESUMEN

Nonvascular photoautotrophs (NVP), including bryophytes, lichens, terrestrial algae, and cyanobacteria, are increasingly recognized as being essential to ecosystem functioning in many regions of the world. Current research suggests that climate change may pose a substantial threat to NVP, but the extent to which this will affect the associated ecosystem functions and services is highly uncertain. Here, we propose a research agenda to address this urgent question, focusing on physiological and ecological processes that link NVP to ecosystem functions while also taking into account the substantial taxonomic diversity across multiple ecosystem types. Accordingly, we developed a new categorization scheme, based on microclimatic gradients, which simplifies the high physiological and morphological diversity of NVP and world-wide distribution with respect to several broad habitat types. We found that habitat-specific ecosystem functions of NVP will likely be substantially affected by climate change, and more quantitative process understanding is required on: (1) potential for acclimation; (2) response to elevated CO2 ; (3) role of the microbiome; and (4) feedback to (micro)climate. We suggest an integrative approach of innovative, multimethod laboratory and field experiments and ecophysiological modelling, for which sustained scientific collaboration on NVP research will be essential.


Asunto(s)
Briófitas , Líquenes , Ecosistema , Cambio Climático , Plantas , Briófitas/fisiología , Líquenes/fisiología
6.
J Cardiovasc Electrophysiol ; 34(1): 135-141, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36300705

RESUMEN

INTRODUCTION: BNP elevation in patients with AF is observed in the absence of heart failure; however, prior mechanistic studies have not included direct left atrial pressure measurements. This study sought to understand how emptying function of the left atrial appendage (LAA) and LAA dimension contributes to brain-natriuretic peptide elevations (BNP) in atrial fibrillation (AF) accounting for left atrial pressure (LAP). METHODS: 132 patients referredfor left atrial appendage occlusion (LAAO) were prospectively enrolled in this study. BNP levels and LAP were measured just before LAAO. Statistical analysis considered BNP, rhythm at time of procedure, LAP, LAA morphology, LAA size (ostial diameter, depth, volume), LAA emptying velocity, CHADS2-VASc score, body mass index (BMI), left ventricular ejection fraction (LVEF), estimated glomerular filtration rate (eGFR), and obstructive sleep apnea (OSA) diagnosis as covariates. RESULTS: Bivariate statistical analysis demonstrated positive associations with age, LAA ostial diameter, depth, and volume, LAP, AF status at time of measurement, OSA, and CHADS2-VASc score. BNP was negatively associated with LVEF, eGFR, LAA emptying velocity and BMI. With multivariate logistic regression including LAP as covariate, significant relationships between BNP and AF/AFL(OR 1.99 [1.03, 3.85]), LAP (OR 1.13 [1.06, 1.20]), LAA diameter (OR 1.14 [1.03, 1.27]), LAA depth (OR 1.14 [1.07, 1.22]), and LAA emptying velocity (OR 0.97 [0.96,0.99]) were observed; however, no significant associations were seen with LAA morphology or CHADS2-VASc score. CONCLUSIONS: BNP elevations in AF are associated with LAA size and function, but not CHADS2-VASc score or appendage morphology after accounting for changes in LAP.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Péptido Natriurético Encefálico , Humanos , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/patología , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/metabolismo , Ecocardiografía Transesofágica , Péptido Natriurético Encefálico/sangre , Péptido Natriurético Encefálico/química , Apnea Obstructiva del Sueño/diagnóstico , Volumen Sistólico , Función Ventricular Izquierda
7.
J Chem Inf Model ; 63(7): 2196-2206, 2023 04 10.
Artículo en Inglés | MEDLINE | ID: mdl-36977188

RESUMEN

The nation's opioid overdose deaths reached an all-time high in 2021. The majority of deaths are due to synthetic opioids represented by fentanyl. Naloxone, which is a FDA-approved reversal agent, antagonizes opioids through competitive binding at the µ-opioid receptor (mOR). Thus, knowledge of the opioid's residence time is important for assessing the effectiveness of naloxone. Here, we estimated the residence times (τ) of 15 fentanyl and 4 morphine analogs using metadynamics and compared them with the most recent measurement of the opioid kinetic, dissociation, and naloxone inhibitory constants (Mann et al. Clin. Pharmacol. Therapeut. 2022, 120, 1020-1232). Importantly, the microscopic simulations offered a glimpse at the common binding mechanism and molecular determinants of dissociation kinetics for fentanyl analogs. The insights inspired us to develop a machine learning approach to analyze the kinetic impact of fentanyl's substituents based on the interactions with mOR residues. This proof-of-concept approach is general; for example, it may be used to tune ligand residence times in computer-aided drug discovery.


Asunto(s)
Analgésicos Opioides , Naloxona , Analgésicos Opioides/farmacología , Naloxona/farmacología , Naloxona/metabolismo , Fentanilo/metabolismo , Fentanilo/farmacología , Morfina/química , Receptores Opioides mu/metabolismo , Antagonistas de Narcóticos
8.
Europace ; 25(9)2023 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-37584233

RESUMEN

AIMS: Incomplete left atrial appendage occlusion (LAAO) due to peri-device leak (PDL) is a limitation of the therapy. The Amulet IDE trial is the largest randomized head-to-head trial comparing the Amulet and Watchman 2.5 LAAO devices with fundamentally different designs. The predictors and mechanistic factors impacting differences in PDLs within the Amulet IDE trial are assessed in the current analysis. METHODS AND RESULTS: An independent core lab analysed all images for the presence or absence of severe PDL (>5 mm). The incidence, mechanistic factors, predictors using propensity score-matched controls, and evolution of severe PDLs through 18 months were assessed. Of the 1878 patients randomized in the trial, the Amulet occluder had significantly fewer severe PDLs than the Watchman device at 45 days (1.1 vs. 3.2%, P < 0.001) and 12 months (0.1 vs. 1.1%, P < 0.001). Off-axis deployment or missed lobes were leading mechanistic PDL factors in each device group. Larger left atrial appendage (LAA) dimensions including orifice diameter, landing zone diameter, and depth predicted severe PDL with the Watchman device, with no significant anatomical limitations noted with the Amulet occluder. Procedural and device implant predictors were found with the Amulet occluder attributed to the learning curve with the device. A majority of Watchman device severe PDLs did not resolve over time through 18 months. CONCLUSION: The dual-occlusive Amplatzer Amulet LAA occluder provided improved LAA closure compared with the Watchman 2.5 device. Predictors and temporal observations of severe PDLs were identified in the Amulet IDE trial. CLINICAL TRIAL REGISTRATION: https://clinicaltrials.gov Unique identifier NCT02879448.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Procedimientos Quirúrgicos Cardíacos , Dispositivo Oclusor Septal , Accidente Cerebrovascular , Humanos , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/complicaciones , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Resultado del Tratamiento , Dispositivo Oclusor Septal/efectos adversos , Cateterismo Cardíaco/efectos adversos , Accidente Cerebrovascular/etiología
9.
J Physiol ; 600(8): 1867-1888, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35067970

RESUMEN

The capillary module (CM), consisting of parallel capillaries from terminal arteriole to post-capillary venule, is classically considered to be the building block of complex capillary networks. In skeletal muscle, CMs form interconnected columns spanning thousands of microns, which we recently described as the capillary fascicle. However, detailed evaluation of CM haemodynamics has not been described, and may provide insight into mechanisms of blood flow regulation in the microcirculation. We used intravital videomicroscopy from resting extensor digitorum longus muscle in rats (n = 9 networks, 112 capillary modules), as well as dual-phase computational modelling of blood flow in simulated CM geometries. We found that the mean driving pressure across CMs was 3.236 ± 1.833 mmHg. Red blood cell (RBC) flow was independent of CM resistance, and the ratio of blood flow in adjacent modules was not correlated with their ratio of resistances. In simulated CM geometries, increases to driving pressure produced a direct linear increase to RBC and plasma flow, with no changes to RBC distribution; increases to arteriolar inflow haematocrit resulted in increased RBC flow, but with viscosity-dependent increases to CM resistance. CM RBC flow heterogeneity was higher than plasma flow heterogeneity in experimental data, in contrast to simulated geometries, suggesting that time-dependent flow variability may have important consequences for RBC distribution. In summary, these findings suggest that CMs are active participants in microvascular flow regulation, likely achieved through adjustments to CM driving pressure using pre- and post-capillary loci of flow control. Increases to CM viscosity may be important during the regulation of functional hyperaemia. KEY POINTS: The capillary module (CM), consisting of parallel capillaries from the arteriole to venule, is classically considered to be the building block of capillary networks in skeletal muscle. A detailed evaluation of module haemodynamics may provide insight into mechanisms of blood flow regulation in the microcirculation. Using experimental data from resting skeletal muscle in rats, as well as dual-phase computational models of blood flow, we analysed haemodynamic relationships and the impact of variations to boundary conditions on red blood cell and plasma distribution. We showed that driving pressure across CMs is low, and that simulated increases to inflow haematocrit have important viscosity-dependent effects on module resistance. We found that red blood cell flow was independent from module resistance, which strongly suggests the regulation of driving pressure at the level of the capillary module using pre- and post-capillary loci of flow control. These findings place CMs as central participants in microvascular flow regulation, with important consequences for disease and functional hyperaemia.


Asunto(s)
Capilares , Hiperemia , Animales , Velocidad del Flujo Sanguíneo , Capilares/fisiología , Hemodinámica , Humanos , Microcirculación , Músculo Esquelético/irrigación sanguínea , Ratas
10.
Circulation ; 144(19): 1543-1552, 2021 11 09.
Artículo en Inglés | MEDLINE | ID: mdl-34459659

RESUMEN

BACKGROUND: Percutaneous closure of the left atrial appendage (LAA) is an alternative to chronic oral anticoagulation to reduce stroke risk in patients with nonvalvular atrial fibrillation. The Amulet IDE trial (Amplatzer Amulet Left Atrial Appendage Occluder IDE Trial) was designed to evaluate the safety and effectiveness of the dual-seal mechanism of the Amulet LAA occluder compared with the Watchman device. METHODS: Patients with nonvalvular atrial fibrillation at increased risk of stroke were randomly assigned (1:1) to undergo percutaneous implantation of a LAA occluder with the Amulet occluder or Watchman device. The primary end points included safety (composite of procedure-related complications, all-cause death, or major bleeding at 12 months), effectiveness (composite of ischemic stroke or systemic embolism at 18 months), and the rate of LAA occlusion at 45 days. Prespecified secondary end points included a composite of all stroke, systemic embolism, or cardiovascular/unexplained death at 18 months, major bleeding at 18 months, and superiority test of the 3 primary end points. RESULTS: A total of 1878 patients were enrolled. The Amulet occluder was noninferior to the Watchman device for the primary safety end point (14.5% versus 14.7%; difference=-0.14 [95% CI, -3.42 to 3.13]; P<0.001 for noninferiority). Major bleeding and all-cause death were similar between groups (10.6% versus 10.0% and 3.9% versus 5.1%, respectively). Procedure-related complications were higher for the Amulet occluder (4.5% versus 2.5%), largely related to more frequent pericardial effusion and device embolization. The Amulet occluder was noninferior to the Watchman device for the primary effectiveness end point (2.8% versus 2.8%; difference=0.00 [95% CI, -1.55 to 1.55]; P<0.001 for noninferiority), and the composite of stroke, systemic embolism, or cardiovascular/unexplained death (5.6% versus 7.7%, difference=-2.12 [95% CI, -4.45 to 0.21]; P<0.001 for noninferiority). The rate of major bleeding was similar between groups (11.6% versus 12.3%; difference=-0.71 [95% CI, -3.72 to 2.31]; P=0.32 for superiority). LAA occlusion was higher for the Amulet occluder than for the Watchman device (98.9% versus 96.8%; difference=2.03 [95% CI, 0.41-3.66]; P<0.001 for noninferiority; P=0.003 for superiority). CONCLUSIONS: The Amulet occluder was noninferior for safety and effectiveness of stroke prevention for nonvalvular atrial fibrillation compared with the Watchman device and superior for LAA occlusion. Procedure-related complications were higher with the Amulet occluder and decreased with operator experience. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02879448.


Asunto(s)
Dispositivo Oclusor Septal/normas , Accidente Cerebrovascular/terapia , Anciano , Femenino , Humanos , Masculino
11.
Circulation ; 143(18): 1754-1762, 2021 05 04.
Artículo en Inglés | MEDLINE | ID: mdl-33820423

RESUMEN

BACKGROUND: Left atrial appendage (LAA) occlusion provides an alternative to oral anticoagulation for thromboembolic risk reduction in patients with nonvalvular atrial fibrillation. Since regulatory approval in 2015, the WATCHMAN device has been the only LAA closure device available for clinical use in the United States. The PINNACLE FLX study (Protection Against Embolism for Nonvalvular AF Patients: Investigational Device Evaluation of the Watchman FLX LAA Closure Technology) evaluated the safety and effectiveness of the next-generation WATCHMAN FLX LAA closure device in patients with nonvalvular atrial fibrillation in whom oral anticoagulation is indicated, but who have an appropriate rationale to seek a nonpharmaceutical alternative. METHODS: This was a prospective, nonrandomized, multicenter US Food and Drug Administration study. The primary safety end point was the occurrence of one of the following events within 7 days after the procedure or by hospital discharge, whichever was later: death, ischemic stroke, systemic embolism, or device- or procedure-related events requiring cardiac surgery. The primary effectiveness end point was the incidence of effective LAA closure (peri-device flow ≤5 mm), as assessed by the echocardiography core laboratory at 12-month follow-up. RESULTS: A total of 400 patients were enrolled. The mean age was 73.8±8.6 years and the mean CHA2DS2-VASc score was 4.2±1.5. The incidence of the primary safety end point was 0.5% with a 1-sided 95% upper CI of 1.6%, meeting the performance goal of 4.2% (P<0.0001). The incidence of the primary effectiveness end point was 100%, with a 1-sided 95% lower CI of 99.1%, again meeting the performance goal of 97.0% (P<0.0001). Device-related thrombus was reported in 7 patients, no patients experienced pericardial effusion requiring open cardiac surgery, and there were no device embolizations. CONCLUSIONS: LAA closure with this next-generation LAA closure device was associated with a low incidence of adverse events and a high incidence of anatomic closure. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02702271.


Asunto(s)
Apéndice Atrial/fisiopatología , Anciano , Humanos , Estudios Prospectivos , Resultado del Tratamiento
12.
Eur J Neurosci ; 56(3): 4107-4120, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35703007

RESUMEN

Neuroimaging studies using univariate and multivariate approaches have shown that the fusiform face area (FFA) and parahippocampal place area (PPA) respond selectively to images of faces and places. The aim of this study was to determine the extent to which this selectivity to faces or places is based on the shape or texture properties of the images. Faces and houses were filtered to manipulate their texture properties, while preserving the shape properties (spatial envelope) of the images. In Experiment 1, multivariate pattern analysis (MVPA) showed that patterns of fMRI response to faces and houses in FFA and PPA were predicted by the shape properties, but not by the texture properties of the image. In Experiment 2, a univariate analysis (fMR-adaptation) showed that responses in the FFA and PPA were sensitive to changes in both the shape and texture properties of the image. These findings can be explained by the spatial scale of the representation of images in the FFA and PPA. At a coarser scale (revealed by MVPA), the neural selectivity to faces and houses is sensitive to variation in the shape properties of the image. However, at a finer scale (revealed by fMR-adaptation), the neural selectivity is sensitive to the texture properties of the image. By combining these neuroimaging paradigms, our results provide insights into the spatial scale of the neural representation of faces and places in the ventral-temporal cortex.


Asunto(s)
Corteza Visual , Adaptación Fisiológica , Mapeo Encefálico , Imagen por Resonancia Magnética , Reconocimiento Visual de Modelos/fisiología , Estimulación Luminosa , Lóbulo Temporal/diagnóstico por imagen , Lóbulo Temporal/fisiología , Corteza Visual/fisiología
13.
Microcirculation ; 29(6-7): e12751, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35146836

RESUMEN

OBJECTIVE: The aim of this study was to develop a tool to visualize and quantify hemodynamic information, such as hemoglobin concentration and hematocrit, within microvascular networks recorded in vivo using intravital video microscopy. Additionally, we aimed to facilitate the 3-D reconstruction of the microvascular networks. METHODS: Digital images taken from an intravital video microscopy preparation of the extensor digitorum longus muscle in rats for 25 capillary segments were used. The developed algorithm was used to delineate capillaries of interest, calculate the optical density for each pixel in the image, and reconstruct the 3-D capillary geometry using the calculated light path-lengths. Subsequently, the mean corpuscular hemoglobin concentration (MCHC), hemoglobin concentration, and hematocrit for these capillaries were calculated. We evaluated the hematocrit values determined by our methodology by comparing them to those obtained using a previously published method. RESULTS: The hematocrit values from the proposed optical method were strongly correlated with those calculated using published methods r2 (25) = .92, p < .001, and demonstrated excellent agreement with a mean difference of 1.3% and a coefficient of variation (CV) of 11%. The average MCHC, hemoglobin concentration, and light path-lengths were 23.83 g/dl, 8.06 g/dl, and 3.92 µm, respectively. CONCLUSION: The proposed methodology can quantify hemodynamic measurements and produce functional images for visualization of the microcirculation in vivo.


Asunto(s)
Capilares , Músculo Esquelético , Animales , Ratas , Capilares/diagnóstico por imagen , Capilares/fisiología , Hematócrito , Músculo Esquelético/diagnóstico por imagen , Músculo Esquelético/irrigación sanguínea , Microcirculación/fisiología , Hemoglobinas
14.
J Cardiovasc Electrophysiol ; 33(8): 1881-1887, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35175683

RESUMEN

Recently receiving Food and Drug Administration approval, the Amplatzer Amulet™ left atrial appendage occluder device (Abbott Medical Inc.) provides a dual seal mechanism alternative to the commercially available Watchman FLX or Watchman 2.5 device for embolic stroke prevention in patients with nonvalvular atrial fibrillation. This step-by-step review will cover patient selection, preprocedure imaging assessment, device sizing, device preparation, implant target position assessment, implant technique and troubleshooting, and immediate postimplant follow-up.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Dispositivo Oclusor Septal , Accidente Cerebrovascular , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Cateterismo Cardíaco , Humanos , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Resultado del Tratamiento
15.
Catheter Cardiovasc Interv ; 99(6): 1867-1876, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35233927

RESUMEN

BACKGROUND: Though infrequent, incomplete left atrial appendage closure (LAAC) may result from residual leaks. Percutaneous closure has been described though data is limited. METHODS: We compiled a registry from four centers of patients undergoing percutaneous closure of residual leaks following LAAC via surgical means or with the Watchman device. Leak severity was classified as none (no leak), mild (1-2 mm), moderate (3-4 mm), or severe (≥5 mm). Procedural and clinical success was defined as the elimination of leak or mild residual leak at the conclusion of the procedure or follow-up, respectively. RESULTS: Of 72 (age 72.2 ± 9.2 years; 67% male) patients, 53 had undergone prior LAAC using the Watchman device and 19 patients surgical LAAC. Mean CHADS2 -VA2 Sc score was 4.0 ± 1.8. The median leak size was 5 mm, range: 2-13). A total of 13 received Amplatzer Vascular Plug-II, 18 received Amplatzer Duct Occluder-II and 40 patients received coils. One underwent closure using a 21 mm-Watchman. Procedural success was 94%. Zero surgical and nine Watchman patients (13%) had a residual leak at procedural-end (five mild, three moderate, and one severe)-only one patient had no reduction in leak size. Overall leak size reduction was 94%. Two (3%) had intraoperative pericardial effusion. There were no device embolizations, device-related thrombi, or procedural deaths. Clinical success was maintained at 94%. Two had cerebrovascular accidents-at 2 days (transient ischemic attack) and 10 months postprocedure. Two had major bleeding outside the 30-day periprocedural window. CONCLUSION: Percutaneous closure of residual leaks following left atrial appendage closure is feasible and associated with good outcomes. The procedural risk appears to be satisfactory.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Dispositivo Oclusor Septal , Accidente Cerebrovascular , Anciano , Anciano de 80 o más Años , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/terapia , Cateterismo Cardíaco , Femenino , Humanos , Masculino , Persona de Mediana Edad , Sistema de Registros , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Resultado del Tratamiento
16.
Europace ; 24(7): 1119-1126, 2022 07 21.
Artículo en Inglés | MEDLINE | ID: mdl-35025987

RESUMEN

AIMS: There is limited information on what clinical factors are associated with the development of pericardial effusion after leadless pacemaker implantation. We sought to determine predictors of and to develop a risk score for pericardial effusion in patients undergoing Micra leadless pacemaker implantation attempt. METHODS AND RESULTS: Patients (n = 2817) undergoing implant attempt from the Micra global trials were analysed. Characteristics were compared between patients with and without pericardial effusion (including cardiac perforation and tamponade). A risk score for pericardial effusion was developed from 18 pre-procedural clinical variables using lasso logistic regression. Internal validation and future prediction performance were estimated using bootstrap resampling. The scoring system was also externally validated using data from the Micra Acute Performance European and Middle East (MAP EMEA) registry. There were 32 patients with a pericardial effusion [1.1%, 95% confidence interval (CI): 0.8-1.6%]. Following lasso logistic regression, 11 of 18 variables remained in the model from which point values were assigned. The C-index was 0.79 (95% CI: 0.71-0.88). Patient risk score profile ranged from -4 (lowest risk) to 5 (highest risk) with 71.8% patients considered low risk (risk score ≤0), 16.6% considered medium risk (risk score = 1), and 11.7% considered high risk (risk score ≥2) for effusion. The median C-index following bootstrap validation was 0.73 (interquartile range: 0.70-0.75). The C-index based on 9 pericardial effusions from the 928 patients in the MAP EMEA registry was 0.68 (95% CI: 0.52-0.83). The pericardial effusion rate increased significantly with additional Micra deployments in medium-risk (P = 0.034) and high-risk (P < 0.001) patients. CONCLUSION: The overall rate of pericardial effusion following Micra implantation attempt is 1.1% and has decreased over time. The risk of pericardial effusion after Micra implant attempt can be predicted using pre-procedural clinical characteristics with reasonable discrimination. CLINICAL TRIAL REGISTRATION: The Micra Post-Approval Registry (ClinicalTrials.gov identifier: NCT02536118), Micra Continued Access Study (ClinicalTrials.gov identifier: NCT02488681), and Micra Transcatheter Pacing Study (ClinicalTrials.gov identifier: NCT02004873).


Asunto(s)
Marcapaso Artificial , Derrame Pericárdico , Ensayos Clínicos como Asunto , Diseño de Equipo , Humanos , Marcapaso Artificial/efectos adversos , Derrame Pericárdico/diagnóstico , Derrame Pericárdico/epidemiología , Derrame Pericárdico/etiología , Estudios Prospectivos , Factores de Riesgo , Resultado del Tratamiento
17.
J Physiol ; 599(8): 2149-2168, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33595111

RESUMEN

KEY POINTS: The capillary module, consisting of parallel capillaries from arteriole to venule, is classically considered as the building block of complex capillary networks. In skeletal muscle, this structure fails to address how blood flow is regulated along the entire length of the synchronously contracting muscle fibres. Using intravital video microscopy of resting extensor digitorum longus muscle in rats, we demonstrated the capillary fascicle as a series of interconnected modules forming continuous columns that align naturally with the dimensions of the muscle fascicle. We observed structural heterogeneity for module topology, and functional heterogeneity in space and time for capillary-red blood cell (RBC) haemodynamics within a module and between modules. We found that module RBC haemodynamics were independent of module resistance, providing direct evidence for microvascular flow regulation at the level of the capillary module. The capillary fascicle is an updated paradigm for characterizing blood flow and RBC distribution in skeletal muscle capillary networks. ABSTRACT: Capillary networks are the fundamental site of oxygen exchange in the microcirculation. The capillary module (CM), consisting of parallel capillaries from terminal arteriole (TA) to post-capillary venule (PCV), is classically considered as the building block of complex capillary networks. In skeletal muscle, this structure fails to address how blood flow is regulated along the entire length of the synchronously contracting muscle fibres, requiring co-ordination from numerous modules. It has previously been recognized that TAs and PCVs interact with multiple CMs, creating interconnected networks. Using label-free intravital video microscopy of resting extensor digitorum longus muscle in rats, we found that these networks form continuous columns of linked CMs spanning thousands of microns, herein denoted as the capillary fascicle (CF); this structure aligns naturally with the dimensions of the muscle fascicle. We measured capillary-red blood cell (RBC) haemodynamics and module topology (n = 9 networks, 327 modules, 1491 capillary segments). The average module had length 481 µm, width 157 µm and 9.51 parallel capillaries. We observed structural heterogeneity for CM topology, and functional heterogeneity in space and time for capillary-RBC haemodynamics within a module and between modules. There was no correlation between capillary RBC velocity and lineal density. A passive inverse relationship between module length and haemodynamics was remarkably absent, providing direct evidence for microvascular flow regulation at the level of the CM. In summary, the CF is an updated paradigm for characterizing RBC distribution in skeletal muscle, and strengthens the theory of capillary networks as major contributors to the signal that regulates capillary perfusion.


Asunto(s)
Capilares , Músculo Esquelético , Animales , Eritrocitos , Microcirculación , Fibras Musculares Esqueléticas , Ratas
18.
Microcirculation ; 28(6): e12699, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-33853202

RESUMEN

How oxygen (O2 ) supply to capillaries is regulated to match the tissue's demand is unknown. Erythrocytes have been proposed as sensors in this regulatory mechanism since they release ATP, a vasodilator, in an oxygen saturation (SO2 )-dependent manner. ATP causes hyperpolarization of endothelial cells resulting in conducted vasodilation to arterioles. OBJECTIVE: We propose individual capillary units can regulate their own O2 supply by direct communication to upstream arterioles via electrically coupled endothelium. METHODS: To test this hypothesis, we developed a transparent micro-exchange device for localized O2 exchange with surface capillaries of intact tissue. The device was fabricated with an O2 permeable micro-outlet 0.2 × 1.0 mm. Experiments were performed on rat extensor digitorum longus (EDL) muscle using dual wavelength video microscopy to measure capillary hemodynamics and erythrocyte SO2 . Responses to local O2 perturbations were measured with only capillaries positioned over the micro-outlet. RESULTS: Step changes in the gas mixture %O2 caused physiological changes in erythrocyte SO2 , and appropriate changes in flow to offset the O2 challenge if at least 3-4 capillaries were stimulated. CONCLUSION: These results support our hypothesis that individual capillary units play a role in regulating their erythrocyte supply in response to a changing O2 environment.


Asunto(s)
Capilares , Adenosina Trifosfato/metabolismo , Animales , Capilares/metabolismo , Células Endoteliales/metabolismo , Microcirculación , Músculo Esquelético/metabolismo , Oxígeno/metabolismo , Saturación de Oxígeno , Ratas
19.
J Cardiovasc Electrophysiol ; 32(4): 1044-1052, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33512055

RESUMEN

BACKGROUND: Nonchicken wing left atrial appendage (LAA) morphology is associated with higher risk for stroke in patients with atrial fibrillation (AF) than chicken wing (CW) morphology. OBJECTIVE: Assess whether LAA morphology predicts the formation of LAA thrombus independent of age, sex, presenting rhythm, left ventricular ejection fraction (LVEF), or anticoagulant use. METHODS: A cross-sectional analysis was performed on patients prospectively enrolled in the Vanderbilt LAA Registry or presenting for transesophageal echocardiogram (TEE) between January 1, 2015, and November 1, 2017 (n = 306). Two physicians independently reviewed TEEs interpreted as having LAA thrombus. Determination of LAA morphology, ejection velocity, and presence of thrombus (n = 102) were based on 0°, 45°, 90°, and 135° TEE views. The control cohort (n = 204) included consecutive AF patients undergoing TEE without LAA thrombus. RESULTS: LAA morphology in patients with LAA thrombus was: 35% windsock, 47% broccoli, and 12% CW. Windsock (odds ratio [OR], 4.0; 95% confidence interval [CI]: 1.7-9.3, p = .001) and broccoli (OR, 6.6; 95% CI: 2.6-16.6; p < .001) morphology were higher risk for thrombus compared to CW. Female sex predicted higher-odds for LAA thrombus (OR, 2.6; 95% CI: 1.4-4.8; p = .002) as did LAA-EV < 20 cm/s (OR, 11.12; 95% CI: 5.6-22.1). Anticoagulation use (OR, 0.5; 95% CI: 0.3-0.9; p = .03) and higher LVEF (OR, 0.95; 95% CI: 0.93-0.98; p < .001) were associated with lower risk. In patients with a CW morphology who had LAA thrombus, 4 of the 7 had an LAA-EV < 20 cm/s and acute systolic heart failure with LVEF < 30% or active malignancy. In multivariable linear regression analysis controlling for presenting rhythm, anticoagulant use, age, sex, and LVEF, CW morphology appears relatively protective from LAA thrombus (p = .001). CONCLUSION: CW LAA morphology appears relatively protective against the formation of LAA thrombus.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Trombosis , Apéndice Atrial/diagnóstico por imagen , Fibrilación Atrial/diagnóstico por imagen , Estudios Transversales , Ecocardiografía Transesofágica , Femenino , Humanos , Volumen Sistólico , Trombosis/diagnóstico por imagen , Función Ventricular Izquierda
20.
Glob Chang Biol ; 27(9): 1915-1926, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33421251

RESUMEN

There is deepening interest in how microclimatic refugia can reduce species threat, if suitable climatic conditions are maintained locally, despite global climate change. Microclimates are a particularly important consideration in topographically heterogeneous landscapes, while in some habitats, such as forests and woodlands, microclimates are also extremely labile and affected by management practices that could consequently be used to offset climate change impact. This study explored a conservation priority guild-cyanolichen epiphytes in temperate rainforest-quantifying the niche response to macroclimate, and landscape or woodland stand structures that determine the microclimate. Based on epiphyte survey in a core region of European temperate rainforest (western Scotland), a 'random forest' machine-learning model confirmed a strong cyanolichen response to summer dryness, as well as the effects of distance to running water, topographic heatload and tree species identity, which modify the local moisture regime and/or lichen growth rates. By quantifying this response to macroclimate, landscape and stand structures, it was possible to estimate an extent to which woodland may be expanded in the future, to offset a negative effect of increasing summer dryness projected through to the 2080s. Using current policy as a yardstick, sufficient woodland expansion could be delivered relatively quickly for median impacted sites, but with times to woodland delivery extending over 10, 20 and 25 years for sites at the 75th, 90th and 95th percentiles of cyanolichen decline. Furthermore, the extent of new woodland required, and delivery times, increase almost threefold on average, as new woodland becomes distributed over wider riparian zones. These contrasting implications emphasize an urgent need for afforestation that achieves targeted spatial planning responsive to microclimates as refugia.


Asunto(s)
Microclima , Bosque Lluvioso , Cambio Climático , Escocia , Árboles
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA