Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Tumour Biol ; 42(9): 1010428320958603, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32964798

RESUMEN

This study aimed to investigate whether changes in progastrin-releasing peptide (ProGRP) levels correlate with treatment response and can be used to optimize clinical management of patients with small-cell lung cancer. Patients with small-cell lung cancer (any stage) receiving chemotherapy were eligible. ProGRP was measured in serum/plasma at baseline and after each chemotherapy cycle using the Elecsys® ProGRP assay (Roche Diagnostics). Treatment response was assessed by computed tomography scan. The primary objective was to examine whether changes in ProGRP levels correlated with computed tomography scan results after two cycles of chemotherapy. The prognostic value of ProGRP among patients receiving first-line chemotherapy was also assessed. Overall, 261 patients from six centers were eligible. Among patients with elevated baseline ProGRP (>100 pg/mL), a ProGRP decline after Cycle 2 was associated with nonprogression (area under the curve: 84%; 95% confidence interval: 72.8-95.1; n = 141). ProGRP changes from baseline to end of Cycle 1 were predictive of response, as determined by computed tomography scan 3 weeks later (area under the curve: 87%; 95% confidence interval: 74.1-99.2; n = 137). This was enhanced by repeat measurements, with a 92% area under the curve (95% confidence interval: 85.3-97.8) among patients with ProGRP data after both Cycles 1 and 2 (n = 123); if a patient experienced a ≥25% decline in ProGRP after Cycle 1, and ProGRP remained stable or decreased after Cycle 2, the probability of finding progression on the interim computed tomography scan at the end of Cycle 2 was almost zero (sensitivity: 100%, specificity: 71%). Both ProGRP levels at baseline and at the end of first-line chemotherapy were prognostic; the latter provided a moderately improved hazard ratio of 2.43 (95% confidence interval: 1.33-4.46; n = 110) versus 1.87 (95% confidence interval: 1.04-3.37; n = 216). In summary, for patients with small-cell lung cancer and elevated baseline ProGRP levels, ProGRP may be a simple, reliable, and repeatable tool for monitoring response to chemotherapy and provide valuable prognostic information.


Asunto(s)
Neoplasias Pulmonares/sangre , Fragmentos de Péptidos/sangre , Carcinoma Pulmonar de Células Pequeñas/sangre , Adulto , Anciano , Anciano de 80 o más Años , Algoritmos , Biomarcadores de Tumor/sangre , China , Europa (Continente) , Femenino , Humanos , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/tratamiento farmacológico , Masculino , Persona de Mediana Edad , Pronóstico , Proteínas Recombinantes/sangre , Sensibilidad y Especificidad , Carcinoma Pulmonar de Células Pequeñas/diagnóstico por imagen , Carcinoma Pulmonar de Células Pequeñas/tratamiento farmacológico , Tomografía Computarizada por Rayos X
2.
Tumour Biol ; 40(4): 1010428318772202, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29701125

RESUMEN

In squamous cell carcinoma, squamous cell carcinoma antigen levels are often elevated. This multi-center study evaluated the technical performance of a new Elecsys® squamous cell carcinoma assay, which measures serum squamous cell carcinoma antigen 1 and 2 levels in an equimolar manner, and investigated the potential of squamous cell carcinoma antigen for differential diagnosis of cervical, lung, and head and neck squamous cell carcinoma.Assay precision and method comparison experiments were performed across three European sites. Reference ranges for reportedly healthy individuals were determined using samples from banked European and Chinese populations. Differential diagnosis experiments determined whether cervical, lung, or head and neck cancer could be differentiated from apparently healthy, benign, or other malignant cohorts using squamous cell carcinoma antigen levels alone. Squamous cell carcinoma antigen cut-off levels were calculated based on squamous cell carcinoma antigen levels at 95% specificity. Repeatability coefficients of variation across nine analyte concentrations were ≤5.3%, and intermediate precision coefficients of variation were ≤10.3%. Method comparisons showed good correlations with Architect and Kryptor systems (slopes of 1.1 and 1.5, respectively). Reference ranges for 95th percentiles for apparently healthy individuals were 2.3 ng/mL (95% confidence interval: 1.9-3.8; European cohort, n = 153) and 2.7 ng/mL (95% confidence interval: 2.2-3.3; Chinese cohort, n = 146). Strongest differential diagnosis results were observed for cervical squamous cell carcinoma: receiver operating characteristic analysis showed that squamous cell carcinoma antigen levels (2.9 ng/mL cut-off) differentiate cervical squamous cell carcinoma (n = 127) from apparently healthy females (n = 286; area under the curve: 86.2%; 95% confidence interval: 81.8-90.6; sensitivity: 61.4%; specificity: 95.6%), benign diseases (n = 187; area under the curve: 86.3%; 95% confidence interval: 81.2-91.3; sensitivity: 61.4%; specificity: 95.0%), and other cervical cancers (n = 157; area under the curve: 78.9%; 95% confidence interval: 70.8-87.1; sensitivity: 61.4%; specificity: 86.7%). Squamous cell carcinoma may also aid in the differential diagnosis of lung cancer. The Elecsys squamous cell carcinoma assay exhibited good technical performance and is suitable for differential diagnosis of cervical squamous cell carcinoma in clinical practice.


Asunto(s)
Antígenos de Neoplasias/análisis , Carcinoma de Pulmón de Células no Pequeñas/diagnóstico , Neoplasias de Cabeza y Cuello/diagnóstico , Técnicas Inmunológicas/métodos , Neoplasias Pulmonares/diagnóstico , Serpinas/análisis , Neoplasias del Cuello Uterino/diagnóstico , Adulto , Anciano , Carcinoma de Pulmón de Células no Pequeñas/inmunología , Diagnóstico Diferencial , Femenino , Neoplasias de Cabeza y Cuello/inmunología , Humanos , Neoplasias Pulmonares/inmunología , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Neoplasias del Cuello Uterino/inmunología
3.
J Biomech ; 40(6): 1310-7, 2007.
Artículo en Inglés | MEDLINE | ID: mdl-16831441

RESUMEN

Orthopedic reconstruction of blunt chest trauma can aid restoration of pulmonary function to reduce the mortality associated with serial rib fractures and flail chest injuries. Contemporary chest wall reconstruction requires contouring of generic plates to the complex surface geometry of ribs. This study established a biometric foundation to generate specialized, anatomically contoured osteosynthesis hardware for rib fracture fixation. On human cadaveric ribs three through nine, the surface geometry pertinent to anatomically conforming osteosynthesis plates was characterized by quantifying the apparent rib curvature C(A), the longitudinal twist alpha(LT) along the diaphysis, and the unrolled curvature C(U). In addition, the rib cross-sectional geometry pertinent to intramedullary fixation strategies was characterized in terms of cross-section height, width, area, and cortex thickness. The rib surface exhibited a curvature C(A) ranging from 3.8 m(-1) in the anteromedial section of rib seven to 17.3 m(-1) in the posterior section of rib three. All ribs had in common a longitudinal twist alpha(LT), ranging from 41-60 degrees. The unrolled curvature C(U) decreased gradually from ribs three to five, and increased gradually with reversed orientation from rib six to nine. The cross-sectional area remained constant along the rib diaphysis. However, the medullary canal increased in size from 29.9 mm(2) posteriorly to 41.2 mm(2) in anterior rib segments. Results of this biometric rib characterization describe a novel strategy for intraoperative plate contouring and provide a foundation for the development of specialized rib osteosynthesis strategies.


Asunto(s)
Placas Óseas , Modelos Anatómicos , Procedimientos de Cirugía Plástica/instrumentación , Ajuste de Prótesis/métodos , Costillas/anatomía & histología , Costillas/cirugía , Procedimientos Quirúrgicos Torácicos/instrumentación , Simulación por Computador , Femenino , Humanos , Técnicas In Vitro , Masculino , Persona de Mediana Edad , Modelos Biológicos , Procedimientos de Cirugía Plástica/métodos , Costillas/fisiología , Procedimientos Quirúrgicos Torácicos/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA