1.
Clin Chem Lab Med ; 61(7): 1280-1287, 2023 06 27.
Artículo en Inglés | MEDLINE | ID: mdl-37043622

RESUMEN

OBJECTIVES: Monitoring quality indicators (QIs) is an important part of laboratory quality assurance (QA). Here, the Canadian Society of Clinical Chemists (CSCC) Point of Care Testing (POCT) and QI Special Interest Groups describe a process for establishing and monitoring QIs for POCT glucose testing. METHODS: Key, error prone steps in the POCT glucose testing process were collaboratively mapped out, followed by risk assessment for each step. Steps with the highest risk and ability to detect a non-conformance were chosen for follow-up. These were positive patient identification (PPID) and repeat of critically high glucose measurements. Participating sites were asked to submit aggregate data for these indicators from their site(s) for a one-month period. The PPID QI was also included as part of a national QI monitoring program for which fifty-seven sites submitted data. RESULTS: The percentage of POCT glucose tests performed without valid PPID ranged from 0-87%. Sites without Admission-Discharge-Transfer (ADT) connectivity to POCT meters were among those with the highest percentage of POCT glucose tests performed without valid PPID. The percentage repeated critically high glucose measurements ranged from 0-50%, indicating low compliance with this recommendation. A high rate of discordance was also noted when critically high POCT glucose measurements were repeated, demonstrating the importance of repeat testing prior to insulin administration. CONCLUSIONS: Here, a process for establishing these QIs is described, with preliminary data for two QIs chosen from this process. The findings demonstrate the importance of QIs for identification and comparative performance monitoring of non-conformances to improve POCT quality.


Asunto(s)
Glucosa , Sistemas de Atención de Punto , Indicadores de Calidad de la Atención de Salud , Canadá , Opinión Pública , Glucosa/química , Pruebas en el Punto de Atención , Humanos
2.
Int J Health Geogr ; 22(1): 38, 2023 Dec 20.
Artículo en Inglés | MEDLINE | ID: mdl-38124128

RESUMEN

OBJECTIVES: To perform geographic contour analysis of sea and land ambulance rescue times in an archipelago subject to super typhoons; to design point-of-care testing strategies for medical emergencies and weather disasters made more intense by global warming and rising oceans; and to assess needs for prehospital testing on spatial care paths that accelerate decision making, increase efficiency, improve outcomes, and enhance standards of care in island nations. METHODS: We performed needs assessments, inspected healthcare facilities, and collected ambulance rescue times from professionals in the Bantayan Archipelago, Philippines. We mapped sea/land ambulance rescue routes and time contours. To reveal gaps, we statistically compared the fastest and slowest patient rescue times from islands/islets and barangays to the District Hospital on Bantayan Island. We developed spatial care paths (the fastest routes to care) for acute myocardial infarction, community care, and infectious diseases. We generated a compendium of prehospital diagnostic testing and integrated outcomes evidence, diagnostic needs, and public health goals to recommend point-of-care strategies that build geographic health resilience. RESULTS: We observed limited access to COVID-19 assays, absence of blood gas/pH testing for critical care support, and spatial gaps in land and airborne rescues that worsened during inclement weather and sea swells. Mean paired differences (slowest-fastest) in ambulance rescue times to the District Hospital for both islands and barangays were significant (P < 0.0001). Spatial care path analysis showed where point-of-care cardiac troponin testing should be implemented for expedited care of acute myocardial infarction. Geospatial strengths comprised distributed primary care that can be facilitated by point-of-care testing, logical interisland transfers for which decision making and triage could be accelerated with onboard diagnostics, and healthcare networks amenable to medical advances in prehospital testing that accelerate treatment. CONCLUSIONS: Point-of-care testing should be positioned upstream close to homes and island populations that have prolonged rescue time contours. Geospatially optimized point-of-need diagnostics and distributed prehospital testing have high potential to improve outcomes. These improvements will potentially decrease disparities in mortality among archipelago versus urban dwellers, help improve island public health, and enhance resilience for increasingly adverse and frequent climate change weather disasters that impact vulnerable coastal areas. [350 words].


Asunto(s)
Desastres , Infarto del Miocardio , Humanos , Sistemas de Atención de Punto , Calentamiento Global , Tiempo (Meteorología) , Planificación de Atención al Paciente
4.
JACC Case Rep ; 29(16): 102462, 2024 Aug 21.
Artículo en Inglés | MEDLINE | ID: mdl-39295815

RESUMEN

A patient with metastatic renal cell carcinoma on axitinib and pembrolizumab had elevated high-sensitivity cardiac troponin T and normal high-sensitivity cardiac troponin I with unremarkable cardiac investigations. A noncardiac cause (myositis) was the likely cause for cardiac troponin T elevation. Cardiac troponin I may be a more appropriate marker to support a myocarditis diagnosis with concurrent myositis.

5.
J Biol Chem ; 287(45): 37715-31, 2012 Nov 02.
Artículo en Inglés | MEDLINE | ID: mdl-22989875

RESUMEN

Kindlin-3, a 75-kDa protein, has been shown to be critical for hemostasis, immunity, and bone metabolism via its role in integrin activation. The Kindlin family is hallmarked by a FERM domain comprised of F1, F2, and F3 subdomains together with an N-terminal F0 domain and a pleckstrin homology domain inserted in the F2 domain. Recombinant Kindlin-3 was cloned, expressed, and purified, and its domain organization was studied by x-ray scattering and other techniques to reveal an extended conformation. This unusual elongated structure is similar to that found in the paralogue Talin head domain. Analytical ultracentrifugation experiments indicated that Kindlin-3 forms a ternary complex with the Talin and ß-integrin cytoplasmic tails. NMR showed that Kindlin-3 specifically recognizes the membrane-distal tail NPXY motif in both the ß(1A) and ß(1D) isoforms, although the interaction is stronger with ß(1A). An upstream Ser/Thr cluster in the tails also plays a critical role. Overall these data support current biological, clinical, and mutational data on Kindlin-3/ß-tail binding and provide novel insights into the overall conformation and interactions of Kindlin-3.


Asunto(s)
Secuencias de Aminoácidos , Proteínas del Citoesqueleto/química , Integrina beta1/química , Conformación Proteica , Secuencia de Aminoácidos , Animales , Fenómenos Biofísicos , Proteínas del Citoesqueleto/genética , Proteínas del Citoesqueleto/metabolismo , Integrina beta1/metabolismo , Espectroscopía de Resonancia Magnética , Proteínas de la Membrana/química , Proteínas de la Membrana/metabolismo , Ratones , Mutación , Unión Proteica , Isoformas de Proteínas/química , Isoformas de Proteínas/metabolismo , Estructura Terciaria de Proteína , Subunidades de Proteína/química , Subunidades de Proteína/metabolismo , Proteínas Recombinantes/química , Proteínas Recombinantes/metabolismo , Dispersión del Ángulo Pequeño , Células Sf9 , Talina/química , Talina/metabolismo , Difracción de Rayos X
7.
Clin Proteomics ; 10(1): 13, 2013 Oct 02.
Artículo en Inglés | MEDLINE | ID: mdl-24088261

RESUMEN

Tremendous efforts have been made over the past few decades to discover novel cancer biomarkers for use in clinical practice. However, a striking discrepancy exists between the effort directed toward biomarker discovery and the number of markers that make it into clinical practice. One of the confounding issues in translating a novel discovery into clinical practice is that quite often the scientists working on biomarker discovery have limited knowledge of the analytical, diagnostic, and regulatory requirements for a clinical assay. This review provides an introduction to such considerations with the aim of generating more extensive discussion for study design, assay performance, and regulatory approval in the process of translating new proteomic biomarkers from discovery into cancer diagnostics. We first describe the analytical requirements for a robust clinical biomarker assay, including concepts of precision, trueness, specificity and analytical interference, and carryover. We next introduce the clinical considerations of diagnostic accuracy, receiver operating characteristic analysis, positive and negative predictive values, and clinical utility. We finish the review by describing components of the FDA approval process for protein-based biomarkers, including classification of biomarker assays as medical devices, analytical and clinical performance requirements, and the approval process workflow. While we recognize that the road from biomarker discovery, validation, and regulatory approval to the translation into the clinical setting could be long and difficult, the reward for patients, clinicians and scientists could be rather significant.

8.
Clin Biochem ; 115: 49-66, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36067872

RESUMEN

The Abbott i-STAT and Siemens Healthineers epoc are commonly used in the provision of care during emergency medical services calls and other settings. Maintaining these systems within manufacturer's temperature claims in these settings poses challenges across the world. This review summarizes solutions that have been reported in the peer-reviewed literature and proposes additional strategies to further address these challenges. A literature search was performed with Clarivate's Web of Science from inception to August 3, 2022. Search terms included i-STAT, epoc, temperature, cold, hot, heat, freeze, frozen, prehospital, disaster, POCT, point of care, blood gas, helicopter, airplane, and ambulance. One author also reviewed manually every issue of the Journal of Paramedic Practice. The search identified 17 solutions for addressing temperature-related challenges with the i-STAT device, nine solutions for i-STAT cartridges, one solution for the epoc device, and one solution for the epoc test card. The majority of solutions were highly portable and consisted of widely available, inexpensive components. The solutions demonstrated only partial or entirely questionable effectiveness in achieving temperature control. The search also identified five reports on the impact of storage temperatures on cartridges and test cards. The reports suggested that these reagents may be able to withstand storage at temperatures outside of manufacturer's claims with only minimal deterioration in performance. The heterogeneity of solutions and the paucity of evidence on their effectiveness suggest that additional strategies are needed to better understand and further address temperature-related challenges with these systems. A collaborative approach and shared decision making are recommended.


Asunto(s)
Servicios Médicos de Urgencia , Humanos , Temperatura , Paramédico , Sistemas de Atención de Punto
11.
BMC Biochem ; 12: 3, 2011 Jan 26.
Artículo en Inglés | MEDLINE | ID: mdl-21269500

RESUMEN

BACKGROUND: General iron-sulfur cluster biosynthesis proceeds through assembly of a transient cluster on IscU followed by its transfer to a recipient apo-protein. The efficiency of the second step is increased by the presence of HscA and HscB, but the reason behind this is poorly understood. To shed light on the function of HscB, we began a study on the nature of its interaction with IscU. Our work suggested that the binding site of IscU is in the C-terminal domain of HscB, and two different triple alanine substitutions ([L92A, M93A, F153A] and [E97A, E100A, E104A]) involving predicted binding site residues had detrimental effects on this interaction. However, the individual contribution of each substitution to the observed effect remains to be determined as well as the possible involvement of other residues in the proposed binding site. RESULTS: In the work reported here, we used isothermal titration calorimetry to characterize the affinity of single alanine HscB mutants for IscU, and subsequently confirmed our results with nuclear magnetic resonance spectroscopy. Alanine substitutions of L92, L96, and F153 severely impaired the ability of HscB to form a complex with IscU; substitutions of R87, R99, and E100 had more modest effects; and substitutions of T89, M93, E97, D103, E104, R152, K156, and S160 had only minor or no detectable effects. CONCLUSIONS: Our results show that the residues of HscB most important for strong interaction with IscU include three hydrophobic residues (L92, L96, and F153); in addition, we identified a number of other residues whose side chains contribute to a lesser extent to the interaction. Our results suggest that the triple alanine substitution at HscB positions 92, 96, and 153 will destabilize the HscB-IscU complex by ΔΔGb≅ 5.7 kcal/mol, equivalent to a ≅ 15000-fold reduction in the affinity of HscB for IscU. We propose that this triple mutant could provide a more definitive test of the functional importance of the HscB-IscU interaction in vivo than those used previously that yielded inconclusive results.


Asunto(s)
Alanina/metabolismo , Proteínas de Escherichia coli/química , Proteínas de Escherichia coli/metabolismo , Proteínas de Choque Térmico/química , Proteínas de Choque Térmico/metabolismo , Proteínas Hierro-Azufre/metabolismo , Sustitución de Aminoácidos , Sitios de Unión , Rastreo Diferencial de Calorimetría , Escherichia coli , Proteínas de Escherichia coli/aislamiento & purificación , Proteínas de Choque Térmico/aislamiento & purificación , Proteínas Hierro-Azufre/química , Proteínas Hierro-Azufre/aislamiento & purificación , Espectroscopía de Resonancia Magnética , Unión Proteica , Conformación Proteica , Estabilidad Proteica
12.
Pract Lab Med ; 25: e00216, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33869709

RESUMEN

OBJECTIVES: Point of Care Testing (POCT) is a rapidly expanding area of clinical laboratory testing and quality assurance is an important area of focus. Quality indicators (QIs) are a quality management system tool that monitors aspects of the testing process to help meet the challenges associated with maintaining high quality patient safety given the growth in POCT. Alberta aims to formalize the development and use of QIs for POCT. DESIGN: and Methods: Potential QIs were identified by reviewing both the current standards and guidelines for QIs in POCT, and the research regarding quality and sources of error in POCT. Quality practices and potential sources of error in POCT were identified by: 1) a Canadian national survey on POCT, and 2) direct observation in two local POCT programs. RESULTS: A proposed selection of QIs in POCT were identified by incorporating the results from these investigations, while considering the unique characteristics of POCT. These QIs monitor the preanalytical, analytical, and post-analytical phases of testing, and support processes. CONCLUSIONS: As POCT volumes and test menu expands, QIs will be a vital tool in monitoring error and maintaining high quality of results. Adoption of formal QIs will support continuous quality improvement and improved patient care.

13.
Clin Biochem ; 91: 31-38, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33444605

RESUMEN

OBJECTIVES: Hydroxocobalamin (OHCob) is an antidote for cyanide poisoning in patients rescued from house fires and is known to cause interference with certain laboratory tests. Consensus is lacking on the extent of this interference and on how to handle these samples. The objectives of this study were to characterize OHCob interference across a wide range of laboratory tests and to develop protocols for identifying and reporting these samples. DESIGNS & METHODS: Patient plasma samples (n = 5) were spiked with OHCob (1.5 mg/mL) and compared to controls without this drug. A series of analytes were measured using chemistry, urinalysis, coagulation, hematology, and blood gas instruments. Dose-response testing was performed on a subset of assays that showed interferences ≥10%. RESULTS: Of the 77 analytes evaluated, 27 (35%) showed interference from OHCob, with chemistry and coagulation analytes showing the greatest effects. Of those affected, 22 analytes had a positive interference, whereas 5 analytes had negative interference. Dose-response studies showed dose-dependent increases and/or decreases consistent with initial spiking studies. Although red in colour, plasma samples with OHCob did not trigger hemolysis index flags, necessitating a special sample identification and reporting protocol. CONCLUSION: OHCob had significant effects on several analytes across different instruments. These findings led to the development of special sample handling and reporting protocols to identify OHCob samples and ensure only accurate results are released. It is vital for emergency departments to document and notify their laboratories whenever blood samples from these patients are drawn.


Asunto(s)
Antídotos/farmacocinética , Análisis Químico de la Sangre , Hidroxocobalamina/farmacocinética , Intoxicación , Cianuro de Potasio , Antídotos/administración & dosificación , Femenino , Humanos , Hidroxocobalamina/administración & dosificación , Masculino , Intoxicación/sangre , Intoxicación/tratamiento farmacológico
14.
J Appl Lab Med ; 6(4): 969-979, 2021 07 07.
Artículo en Inglés | MEDLINE | ID: mdl-33982076

RESUMEN

BACKGROUND: A survey of IFCC members was conducted to determine current and future perspectives on digital innovations within laboratory medicine and healthcare sectors. METHODS: Questions focused on the relevance of digital diagnostic solutions, implementation and barriers to adopting digital technologies, and supplier roles in supporting innovation. Digital diagnostic market segments were defined by solution recipient (laboratory, clinician, patient/consumer, payor) and proximity to core laboratory operations. RESULTS: Digital solutions were of active interest for >90% of respondents. Although solutions to improve core operations were ranked as the most relevant currently, a future shift to technologies beyond core laboratory expertise is expected. A key area of potential differentiation for laboratory customers was clinical decision support. Currently, laboratories collaborate strongly with suppliers of laboratory integration software and information systems, with high expectations for future collaboration in clinical decision support, disease self-management, and population health management. Asia Pacific countries attributed greater importance to adopting digital solutions than those in other regions. Financial burden was the most commonly cited challenge in implementing digital solutions. CONCLUSIONS: Specialists in laboratory medicine are proactively approaching digital innovations and transformation, and there is high enthusiasm and expectation for further collaboration with suppliers and healthcare professionals beyond current core laboratory expertise.


Asunto(s)
Sistemas de Apoyo a Decisiones Clínicas , Telemedicina , Química Clínica , Humanos , Laboratorios , Encuestas y Cuestionarios
15.
Arch Pathol Lab Med ; 144(11): 1352-1371, 2020 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-33106860

RESUMEN

CONTEXT.­: Emergency medical services (EMS) programs have been using point-of-care testing (POCT) for more than 20 years. However, only a handful of reports have been published in all of that time on POCT practices in field settings. OBJECTIVE.­: To provide an overview of POCT practices and failure modes in 3 of Alberta's EMS programs, and to propose risk-mitigation strategies for reducing or eliminating these failure modes. DESIGN.­: Details about POCT practices, failure modes, and risk-mitigation strategies were gathered through (1) conversations with personnel, (2) in-person tours of EMS bases, (3) accompaniment of EMS personnel on missions, (4) internet searches for publicly available information, and (5) a review of laboratory documents. RESULTS.­: Practices were most standardized and robust in the community paramedicine program (single service provider, full laboratory oversight), and least standardized and robust in the air ambulance program (4 service providers, limited laboratory oversight). Common failure modes across all 3 programs included device inoperability due to cold weather, analytical validation procedures that failed to consider the unique challenges of EMS settings, and a lack of real-time electronic transmission of results into the health care record. CONCLUSIONS.­: A provincial framework for POCT in EMS programs is desirable. Such a framework should include appropriate funding models, laboratory oversight of POCT, and relevant expertise on POCT in EMS settings. The framework should also incorporate specific guidance on quality standards that are needed to address the unique challenges of performing POCT in field settings.


Asunto(s)
Servicios Médicos de Urgencia/métodos , Sistemas de Atención de Punto , Pruebas en el Punto de Atención/normas , Medición de Riesgo/métodos , Ambulancias Aéreas/normas , Ambulancias Aéreas/estadística & datos numéricos , Alberta , Medicina Comunitaria/métodos , Medicina Comunitaria/normas , Medicina Comunitaria/estadística & datos numéricos , Servicios Médicos de Urgencia/normas , Servicios Médicos de Urgencia/estadística & datos numéricos , Servicios de Salud/normas , Servicios de Salud/estadística & datos numéricos , Humanos , Pruebas en el Punto de Atención/estadística & datos numéricos , Reproducibilidad de los Resultados , Medición de Riesgo/estadística & datos numéricos
16.
Clin Biochem ; 78: 25-31, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31743687

RESUMEN

OBJECTIVES: Previous analytical evaluations of the Beckman Coulter Access high sensitivity troponin (hsTn) I assay have focused on single platforms and laboratory sites. The purpose of this study was to determine assay robustness across different platforms at multiple sites, platform-specific characteristics, and equivalence to other hsTn methods in a large laboratory network. METHODS: Barricor plasma was used to assess imprecision, linearity, sensitivity (limit of blank and detection, LOB/LOD), and comparability to the conventional AccuTnI+3 and other hsTn assays. Various studies were conducted across a total of 9 laboratories using Beckman DxI800 and Access2 platforms. RESULTS: Within-laboratory precision was <10% across all target patient pool concentrations, however, DxI800 mean values were 20% higher than Access2 in the range of 3.6-44.9 ng/L. LOBs and LODs were lower on DxI800, 0.27 and 0.90 ng/L, respectively, compared to 2.9 and 3.2 ng/L, on Access2. Both showed excellent linearity across the full range. In method comparison to AccuTnI+3, DxI800 had a higher slope (0.9417 versus 0.8495) and positive bias (+18.1% versus -9.9%) compared to Access2, a trend further pronounced at concentrations <150 ng/L. At values <150 ng/L, there was good agreement with Abbott hsTnI (slope = 1.017, r = 0.932), but poor agreement with the Roche hsTnT assay (slope = 1.687, r = 0.589). Inter-laboratory split sample comparisons across 2 DxI800 and 7 Access2 sites showed close agreement, except at low concentrations <10 ng/L where DxI800 was 2.8 ng/L higher (p<0.001). CONCLUSIONS: The Beckman hsTnI assay showed robust analytical performance across different laboratories and platforms. However, discrepancies between platforms were found at low concentrations where rapid acute myocardial infarction (AMI) rule-out decisions occur. These differences have important implications for AMI risk assessment, suggesting that laboratories should develop platform-specific parameters rather than using them interchangibly.


Asunto(s)
Análisis Químico de la Sangre/métodos , Troponina I/sangre , Biomarcadores/sangre , Femenino , Humanos , Límite de Detección , Masculino , Sensibilidad y Especificidad
17.
Biochemistry ; 48(26): 6062-71, 2009 Jul 07.
Artículo en Inglés | MEDLINE | ID: mdl-19492851

RESUMEN

IscU is a scaffold protein that functions in iron-sulfur cluster assembly and transfer. Its critical importance has been recently underscored by the finding that a single intronic mutation in the human iscu gene is associated with a myopathy resulting from deficient succinate dehydrogenase and aconitase [Mochel, F., Knight, M. A., Tong, W. H., Hernandez, D., Ayyad, K., Taivassalo, T., Andersen, P. M., Singleton, A., Rouault, T. A., Fischbeck, K. H., and Haller, R. G. (2008) Am. J. Hum. Genet. 82, 652-660]. IscU functions through interactions with a chaperone protein HscA and a cochaperone protein HscB. To probe the molecular basis for these interactions, we have used NMR spectroscopy to investigate the solution structure of IscU from Escherichia coli and its interaction with HscB from the same organism. We found that wild-type apo-IscU in solution exists as two distinct conformations: one largely disordered and one largely ordered except for the metal binding residues. The two states interconvert on the millisecond time scale. The ordered conformation is stabilized by the addition of zinc or by the single-site IscU mutation, D39A. We used apo-IscU(D39A) as a surrogate for the folded state of wild-type IscU and assigned its NMR spectrum. These assignments made it possible to identify the region of IscU with the largest structural differences in the two conformational states. Subsequently, by following the NMR signals of apo-IscU(D39A) upon addition of HscB, we identified the most perturbed regions as the two N-terminal beta-strands and the C-terminal alpha-helix. On the basis of these results and analysis of IscU sequences from multiple species, we have identified the surface region of IscU that interacts with HscB. We conclude that the IscU-HscB complex exists as two (or more) distinct states that interconvert at a rate much faster than the rate of dissociation of the complex and that HscB binds to and stabilizes the ordered state of apo-IscU.


Asunto(s)
Proteínas de Escherichia coli/química , Proteínas de Choque Térmico/química , Proteínas Hierro-Azufre/química , Sustitución de Aminoácidos , Apoproteínas/química , Apoproteínas/genética , Proteínas de Escherichia coli/genética , Proteínas de Escherichia coli/metabolismo , Proteínas de Choque Térmico/genética , Proteínas de Choque Térmico/metabolismo , Proteínas Hierro-Azufre/genética , Proteínas Hierro-Azufre/metabolismo , Resonancia Magnética Nuclear Biomolecular , Unión Proteica , Conformación Proteica , Dominios y Motivos de Interacción de Proteínas , Estructura Secundaria de Proteína , Proteínas Recombinantes/química , Zinc/química
18.
Clin Chim Acta ; 496: 18-24, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31201816

RESUMEN

INTRODUCTION: The BD Barricor tube uses a novel mechanical separator designed to eliminate gel artifacts, decrease cellular contamination, and improve stability. Here, we evaluated the Barricor tube as a possible replacement for PST using Beckman Coulter analyzers under both optimal, alternative, and suboptimal centrifugation conditions based on BD recommendations. METHODS: Paired PST and Barricor samples were collected from 4 local hospitals and processed based on site-specific preanalytical systems involving automated or manual centrifugation. Centrifugation conditions ranged from 1912 ×g for 10 min (suboptimal), 2060 g for 10 min (alternative), and 4000 ×g for 3 or 10 min (optimal). Tube volume (4.5 vs. 5.5 ml) was also assessed. Forty-three chemistry and immunochemistry analytes were measured on Beckman Coulter DxC and DxI analyzers. RESULTS: Using an automated preanlaytical system with suboptimal spin conditions, no bias between PST and Barricor was observed for all analytes tested except lactate dehydrogenase (LD). Further investigation revealed significant increase in LD when Barricor was spun for 10 min at 1912, 2060 and 4000 ×g, ranging from +7.4-19.4% vs. PST across the entire measurement interval (87-493 U/l). Smaller tube volume was also associated with higher LD. Differences in LD occurred despite no change in other hemolysis markers such as potassium, phosphate, and AST. CONCLUSIONS: LD is most sensitive to varying centrifugation conditions (time and speed) in Barricor tubes. We recommend that BD centrifugation protocols should be closely evaluated to determine if Barricor is equivalent to PST under local preanalytical configurations.


Asunto(s)
Análisis Químico de la Sangre , Recolección de Muestras de Sangre/instrumentación , Inmunoensayo , L-Lactato Deshidrogenasa/sangre , Plasma/química , Humanos
19.
Pract Lab Med ; 14: e00116, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30733990

RESUMEN

OBJECTIVES: Many hospitals cannot afford an hCG assay on a central lab analyzer and turn to point of care testing (POCT) solutions. The Radiometer AQT90 FLEX is a small benchtop immunoareement between the AQT90 and comparator methods for samples with hCG ssay analyzer for use in the laboratory or at the patient bedside. This study evaluated the analytical performance of the AQT90's ßhCG assay. METHODS: Precision was assessed using whole blood patient samples and two levels of quality control. Linearity was assessed by dilution of a high hCG plasma sample. Carryover and hook effect were assessed using high and low hCG samples. Method comparisons were done against Abbott i-STAT Total ßhCG, Beckman Coulter Total ßhCG (5th IS), and Roche hCG+ß. Sample concentrations ranged from<2 IU/L to 4,973 IU/L. RESULTS: Repeatability and within-laboratory precision passed most manufacturer's claims and allowable error criteria. Linearity was validated from<2 IU/L to 4,741 IU/L. Hook effect was not observed up to 2,446,448 IU/L. Carryover was<4.0 ppm. A linear relationship was observed with i-STAT, Beckman and Roche methods. At>20 IU/L, biases were apparent against all three comparator assays (i-STAT: +20%, Roche: +30%, Beckman: +5 to 15%). At ≤20 IU/L, the acceptability of agreement varied according to TAE specifications. Concordance between AQT90 and comparator assays using 5 IU/L as the medical decision level ranged from 69% to 81%. CONCLUSIONS: Overall, the AQT90 hCG assay performed well and would be suitable for smaller suburban or rural hospitals. Some limitations have been noted and should be kept in mind during clinical testing.

20.
J Appl Lab Med ; 3(5): 764-774, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-31639752

RESUMEN

BACKGROUND: Cardiac troponin I (cTnI) 99th percentile cutoffs, used in the diagnosis of acute myocardial infarction, are not standardized across cTnI assays. We compared 3 point-of-care (POC) and 1 central laboratory contemporary cTnI assays against the Abbott high-sensitivity (hs) cTnI to evaluate the analytical concordance and the feasibility of using a single cutoff value for all assays. METHODS: Fresh blood samples collected from 102 inpatients in the coronary care unit were measured on central laboratory instruments (Beckman Coulter DxI AccuTnI+3 TnI, Abbott Architect hs-TnI) and cTnI POC analyzers (Alere Triage Troponin I, Radiometer AQT90, Abbott i-STAT). Agreement and correlation between the contemporary cTnI assays and hs-cTnI assay were assessed using regression analysis. Proportional bias was assessed using Bland-Altman plots. Concordance between the contemporary cTnI and hs-cTnI assays was determined by diagnostic contingency tables at specific cutoffs. RESULTS: Most POC cTnI assays had excellent correlation with the Abbott hs-cTnI method (r 2 = 0.955-0.970) except for Alere Triage (r 2 = 0.617), while proportional bias is evident between all cTnI assays. Overall concordance between POC contemporary cTnI assays and hs-cTnI assay was 80% to 90% at their respective 99th percentile cutoffs. The concordance increased to 90% to 95% when a fixed cutoff of 0.03 to 0.05 ng/mL was used across the assays. CONCLUSIONS: This study demonstrates poor analytical concordance between cTnI assays at the 99th percentile and supports the notion of a single clinical decision limit for cTnI and consequently standardization of diagnostic protocols despite the analytical differences among these assays.


Asunto(s)
Biomarcadores/sangre , Laboratorios/normas , Infarto del Miocardio/sangre , Infarto del Miocardio/diagnóstico , Sistemas de Atención de Punto/estadística & datos numéricos , Troponina I/sangre , Troponina T/sangre , Bioensayo , Femenino , Humanos , Masculino , Triaje/estadística & datos numéricos
SELECCIÓN DE REFERENCIAS