Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 38
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Eur J Clin Invest ; 54(8): e14209, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38597271

RESUMEN

BACKGROUND: In the last few years, percutaneous LAA occlusion (LAAO) has become a plausible alternative in atrial fibrillation (AF) patients with contraindications to anticoagulation therapy. Nevertheless, the optimal antiplatelet strategy following percutaneous LAAO remains to be defined. METHODS: Studies comparing single antiplatelet therapy (SAPT) versus dual antiplatelet therapy (DAPT) following LAAO were systematically searched and screened. The outcomes of interest were ischemic stroke, device-related thrombus (DRT) and major bleeding. A random-effect meta-analysis was performed comparing outcomes in both groups. The moderator effect of baseline characteristics on outcomes was evaluated by univariate meta-regression analyses. RESULTS: Sixteen observational studies with 3255 patients treated with antiplatelet therapy (SAPT, n = 1033; DAPT, n = 2222) after LAAO were included. Mean age was 74.5 ± 8.3 years, mean CHA2DS2-VASc and HAS-BLED scores were 4.3 ± 1.5 and 3.2 ± 1.0, respectively. At a weighted mean follow-up of 12.7 months, the occurrence of stroke (RR 1.33; 95% CI 0.64-2.77; p =.44), DRT (RR 1.52; 95% CI 0.90-2.58; p =.12), and the composite of stroke and DRT (RR 1.26; 95% CI 0.67-2.37; p =.47) did not differ significantly between SAPT and DAPT groups. The rate of major bleedings was also not different between groups (RR 1.41; 95% CI 0.64-3.12; p =.39). CONCLUSIONS: Among AF patients at high bleeding risk undergoing percutaneous LAAO, a post-procedural minimalistic antiplatelet strategy with SAPT did not significantly differ from DAPT regimens regarding the rate of stroke, DRT and major bleeding.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Terapia Antiplaquetaria Doble , Hemorragia , Inhibidores de Agregación Plaquetaria , Humanos , Apéndice Atrial/cirugía , Inhibidores de Agregación Plaquetaria/uso terapéutico , Terapia Antiplaquetaria Doble/métodos , Hemorragia/inducido químicamente , Anciano , Trombosis/prevención & control , Accidente Cerebrovascular Isquémico/prevención & control , Accidente Cerebrovascular/prevención & control , Estudios Observacionales como Asunto , Cierre del Apéndice Auricular Izquierdo
2.
Catheter Cardiovasc Interv ; 98(4): E581-E585, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34128584

RESUMEN

Spontaneous coronary artery dissection (SCAD) can lead to acute coronary syndrome and sudden cardiac death, particularly in young women. Observational data show that, in SCAD patients, both percutaneous coronary intervention and coronary artery bypass grafting seem to be hampered by higher technical complexity, lower success rates, and worse outcomes. As spontaneous healing is a common occurrence, expert consensus advices medical management of the acute phase, when feasible. We present the case of a young woman with SCAD of left anterior descending artery causing myocardial infarction with ST-segment elevation. High-anatomical complexity and unstable conditions of the patient made both medical management and immediate revascularization unfeasible options. Therefore, we decided to implant a percutaneous off-loading mechanical support device to improve coronary perfusion pressure by unloading the left ventricle and preserve cardiac function, preventing worse complications of acute myocardial infarction. This strategy was successful in stabilizing the patient, until the definitive revascularization treatment became an option.


Asunto(s)
Vasos Coronarios , Ventrículos Cardíacos , Disección , Femenino , Humanos , Perfusión , Resultado del Tratamiento
3.
Catheter Cardiovasc Interv ; 97(4): E536-E543, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-32584507

RESUMEN

BACKGROUND: Stroke is a feared complication of transcatheter aortic valve replacement (TAVR) and surgical aortic valve replacement (SAVR). OBJECTIVES: With this meta-analysis we aimed to evaluate the incidence of 30-day stroke with TAVR and SAVR focusing on its possible correlation with surgical risk. METHODS: Major electronic databases were searched for studies published between January 2002 and October 2019 reporting the rates of 30-day stroke after TAVR and SAVR. Data were pooled using fixed- and random-effects models. The primary outcome of the study was stroke rate within 30-day from TAVR or SAVR. Results were stratified according to surgical risk score (high, intermediate and low). RESULTS: A total of 23 studies were identified (TAVR: 14,589 patients; SAVR: 11,681 patients). Regardless of the model used, in the overall population TAVR was associated with a significant reduction in the risk of stroke compared with SAVR (fixed effect: OR 0.78, 95% CI 0.66-0.92, p = .003; random-effects: OR 0.80, 95% CI 0.64-1.00, p = .045). Rates of 30-day stroke after TAVR and SAVR were not significantly different in the high- (OR 1.01, 95% CI 0.44-1.98, p = .105) and intermediate-risk groups (OR 0.92, 95% CI 0.63-1.36, p = .319), while low-risk patients had a lower rate of 30-day stroke after TAVR than SAVR (OR 0.65, 95% CI 0.50-0.83, p < .001). Meta-regression showed a significant association between surgical risk score and 30-day stroke rate (p = .007). CONCLUSIONS: TAVR is associated with a lower risk of 30-day stroke compared with SAVR, mainly as a result of the significant advantage observed in patients at low surgical risk.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Factores de Riesgo , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
4.
Catheter Cardiovasc Interv ; 96(2): 471-472, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32797741

RESUMEN

Transfemoral (TF) transcatheter aortic valve replacement (TAVR) has evolved dramatically. Improvements in technique, devices, operator's experience, and patient selection have resulted in markedly lower rates of procedural complications, thus allowing further technical simplification at every step of the procedure. Implementing a minimalist approach for TF TAVR (including transradial secondary access, angio-guidewire-ultrasound guidance for femoral puncture, and left ventricle guidewire pacing) may improve outcomes and reduce complications without compromising patient safety in contemporary clinical practice. Although this simplified approach is applicable for most patients undergoing TF TAVR, careful patient selection remains of paramount importance.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Arteria Femoral/diagnóstico por imagen , Humanos , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
5.
Catheter Cardiovasc Interv ; 95(5): 991-992, 2020 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-32294329

RESUMEN

Transcatheter aortic valve replacement (TAVR) patients given pacemakers operating in mandatory DDD mode had more ventricular pacing, heart failure hospitalization, and mortality compared with AAI-DDD or VVI modes. AV conduction disturbances are often transient after TAVR. Minimizing ventricular pacing where possible avoids the risk of pacemaker-induced cardiomyopathy. Pacemaker specialists should be consulted for any TAVR patient with mild rhythm abnormalities given the high incidence of AV block. Careful stratification of patients with conduction disturbances during TAVR may help identify the patients who will require an early permanent pacemaker implantation strategy.


Asunto(s)
Bloqueo Atrioventricular , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Estimulación Cardíaca Artificial , Humanos , Enfermedad Iatrogénica , Factores de Riesgo , Resultado del Tratamiento
6.
Catheter Cardiovasc Interv ; 95(4): 817-818, 2020 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-32159294

RESUMEN

Surgical treatment is the gold standard for pure aortic regurgitation (AR). In this study, transcatheter aortic valve replacement (TAVR) appears to be a promising option for inoperable/high-risk patients suffering pure AR. Long-term results and specific patient-level data are needed to better clarify the role of TAVR in pure AR treatment.


Asunto(s)
Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Alemania , Humanos , Factores de Riesgo , Resultado del Tratamiento
7.
Catheter Cardiovasc Interv ; 95(5): 993-1000, 2020 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-31099970

RESUMEN

BACKGROUND: Peripheral arterial disease (PAD) plays a decisive role in the preinterventional selection process of the optimal vascular access site in patients undergoing transcatheter aortic valve implantation (TAVI). However, the impact of PAD on mortality and vascular complications (VCs) in TAVI-treated patients remains unclear. Accordingly, we aimed to assess the outcomes of patients with and without PAD undergoing TAVI, by performing a meta-regression analysis. METHODS: Studies published between January 2002 and March 2018 and reporting outcomes according to the presence of PAD in TAVI patients were identified. Outcome measures analyzed were short-, mid- and long-term mortality, and peri-procedural VC. The interaction between sheath size and PAD on outcomes was also assessed. RESULTS: A total of 26 studies (68,581 TAVI patients, of whom 17,326 with preprocedural PAD) were included in the analysis. Patients with PAD had higher risk of mortality at short- (HR 1.36, 95% confidence interval [CI] 1.13-1.63, p = .0009), mid- (HR 1.18, 95% CI 1.08-1.30, p = .0005), and long-term (HR 1.36, 95% CI 1.24-1.48, p < .0001) follow-up, and higher risk of VC (RR 1.55, 95% CI 1.27; 1.89, p < .0001). Moreover, the adoption of smaller sheaths during TAVI procedures was associated with fewer VC both in PAD and non-PAD patients, but the latter group had a more pronounced benefit. CONCLUSIONS: Patients with pre-existent PAD are at increased risk of all-cause mortality and VC after TAVI. The adoption of smaller sheaths during the procedure seems to be associated with fewer peri-procedural VC both in PAD and non-PAD patients.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Enfermedad Arterial Periférica/fisiopatología , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Hemodinámica , Humanos , Enfermedad Arterial Periférica/diagnóstico , Enfermedad Arterial Periférica/mortalidad , Complicaciones Posoperatorias/epidemiología , Recuperación de la Función , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
8.
Catheter Cardiovasc Interv ; 96(5): E535-E541, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-31912968

RESUMEN

BACKGROUND: Incidence of coronary access (CA) after transcatheter aortic valve replacement (TAVR) at long-term follow-up remains unknown. CA and percutaneous coronary intervention (PCI) after TAVR might present technical challenges, particularly with supra-annular devices. METHODS: Patients undergoing CA after being treated with TAVR at our institution were included in the study. Coronary interventions for coronary obstruction during TAVR procedure were excluded. Incidence, feasibility and outcomes of CA after TAVR were analyzed. RESULTS: Out of 912 patients aged 80 ± 7 years treated with TAVR at our institution between 2007 and 2018, 48 (5.3%) underwent CA at a median follow up of 769 [363-1,471] days. Twenty-one had received a SAPIEN XT, 15 a SAPIEN 3, 6 Corevalve, 2 Evolut Pro, 2 JenaValve, and 2 Lotus valve. PCI was indicated in 26 (54%) cases. Seventeen (35%) procedures were performed for acute coronary syndromes (ACS). Independent predictors of CA after TAVR were younger age, previous PCI, and CABG. CA of both vessels was feasible in all patients with an intra-annular device, while the right coronary artery was not engaged in two patients with a supra-annular valve. PCI was successful in all but one case. All-cause mortality was similar between patients needing CA for ACS and those who had other clinical indications. CONCLUSIONS: In this high-risk AS population, incidence of CA after TAVR at long-term follow-up was rather low. CA and PCI were safe and successful in most cases, with a lower rate of selective CA for supra-annular devices.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Cateterismo Cardíaco , Angiografía Coronaria , Estenosis Coronaria/diagnóstico , Estenosis Coronaria/terapia , Intervención Coronaria Percutánea , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/mortalidad , Angiografía Coronaria/efectos adversos , Angiografía Coronaria/mortalidad , Estenosis Coronaria/mortalidad , Estudios de Factibilidad , Femenino , Prótesis Valvulares Cardíacas , Humanos , Masculino , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Diseño de Prótesis , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
9.
J Cardiovasc Electrophysiol ; 30(6): 854-864, 2019 06.
Artículo en Inglés | MEDLINE | ID: mdl-30827041

RESUMEN

INTRODUCTION: The recently developed second-generation subcutaneous implantable cardioverter defibrillator (S-ICD) and the intermuscular two-incision implantation technique demonstrate potential favorable features that reduce inappropriate shocks and complications. However, data concerning large patient populations are lacking. The aim of this multicentre prospective study was to evaluate the safety and outcome of second-generation S-ICD using the intermuscular two-incision technique in a large population study. METHODS AND RESULTS: The study population included 101 consecutive patients (75% male; mean age, 45 ± 13 years) who received second-generation S-ICD (EMBLEM; Boston Scientific, Marlborough, MA) implantation using the intermuscular two-incision technique as an alternative to the standard implantation technique. Twenty nine (29%) patients were implanted for secondary prevention. Twenty four (24%) patients had a previously implanted transvenous ICD. All patients were implanted without any procedure-related complications. Defibrillation testing was performed in 80 (79%) patients, and ventricular tachycardia was successfully converted at less than or equal to 65 J in 98.75% (79/80) of patients without pulse generator adjustments. During a median follow-up of 21 ± 10 months, no complications requiring surgical revision or local or systemic device-related infections were observed. Ten patients (9.9%) received appropriate and successful shocks for ventricular arrhythmias. Three (2.9%) patients experienced inappropriate shocks due to oversensing the cardiac signal (n = 1), noncardiac signal (n = 1), and a combination of both cardiac and noncardiac signals (n = 1), with one patient requiring device explantation. No patients required device explantation due to antitachycardia pacing indications. CONCLUSIONS: According to our multicentre study, second-generation S-ICD implanted with the intermuscular two-incision technique is an available safe combination and appears to be associated with a low risk of complications, such as inappropriate shocks.


Asunto(s)
Arritmias Cardíacas/terapia , Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Sistema de Conducción Cardíaco/fisiopatología , Frecuencia Cardíaca , Implantación de Prótesis/instrumentación , Prevención Secundaria/instrumentación , Potenciales de Acción , Adolescente , Adulto , Anciano , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatología , Remoción de Dispositivos , Cardioversión Eléctrica/efectos adversos , Femenino , Humanos , Italia , Masculino , Persona de Mediana Edad , Falla de Prótesis , Implantación de Prótesis/efectos adversos , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
12.
Heart Lung Circ ; 24(4): e56-9, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25499594

RESUMEN

A 66 year-old female presented with a refractory hypoxaemia in association with an isolated paralysis of the right hemidiaphragm. Transoesophageal echocardiography (TEE) with both colour Doppler and bubble test demonstrated a significant patent foramen ovale (PFO)-mediated right-to-left shunt (RTLS) without an increased interatrial pressure gradient. The PFO was urgently closed by deployment of an AMPLATZER(®) occluder device, resulting in complete recovery of the arterial oxygen saturation and patient's symptoms. As noted on TEE, the RTLS was due to redirection of blood flow from the inferior vena cava directly through the PFO secondary to distortion of the cardiac anatomy by right hemidiaphragmatic paralysis.


Asunto(s)
Diafragma , Foramen Oval Permeable , Parálisis , Anciano , Diafragma/diagnóstico por imagen , Diafragma/fisiopatología , Diafragma/cirugía , Ecocardiografía Transesofágica , Femenino , Foramen Oval Permeable/complicaciones , Foramen Oval Permeable/diagnóstico por imagen , Foramen Oval Permeable/fisiopatología , Foramen Oval Permeable/cirugía , Humanos , Parálisis/complicaciones , Parálisis/diagnóstico por imagen , Parálisis/fisiopatología , Parálisis/cirugía
14.
G Ital Cardiol (Rome) ; 25(6): 23-37, 2024 Jun.
Artículo en Italiano | MEDLINE | ID: mdl-38912744

RESUMEN

STENT PANORAMA is a project carried out by the Young Interventional Cardiologists of Triveneto coordinated by the Italian Society of Interventional Cardiology (GISE) Veneto delegation. The project includes two parts: the first, here reported, is aimed at describing in a standardized and easily usable way the main technological characteristics of the latest generation of the drug eluting stents (DES) that are most widely used in the Italian cath-labs. The second, to follow, will aim to summarize the main scientific evidence regarding the performance of individual devices with particular reference to subgroups of clinical interest. The ambitious goal of the STENT PANORAMA working group is to provide the interventional cardiologist with a thorough, practical, and functional knowledge of the DES currently available in the modern therapeutic armamentarium to promote a therapeutic strategy tailored to the patient.


Asunto(s)
Stents Liberadores de Fármacos , Humanos , Italia , Intervención Coronaria Percutánea/métodos , Diseño de Prótesis , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/cirugía
15.
Am J Cardiol ; 224: 56-64, 2024 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-38729335

RESUMEN

The long-term safety and effectiveness of transcatheter aortic valve replacement (TAVR) compared with surgical aortic valve replacement (SAVR) in low surgical risk has not been evaluated in a pooled analysis. An electronic database search was conducted for randomized controlled trials with a maximal 5 years clinical and echocardiographic follow-up including low surgical risk patients who underwent TAVR or SAVR. We calculated odds ratio (OR) and 95% confidence intervals (CIs) using a random-effects model. Subgroups analysis was performed for permanent pacemaker implantation and paravalvular leaks. Three randomized controlled trials were included with a total of 2,611 low surgical risk patients (Society of Thoracic Surgeons score <4%). Compared with SAVR, the TAVR group had similar rates of all-cause mortality (OR 0.94,95% CI 0.65 to 1.37, p = 0.75) and disabling stroke (OR 0.84, 95% CI 0.52 to 1.36, p = 0.48). No significant differences were registered in the TAVR group in terms of major cardiovascular events (OR 0.96, 95% CI 0.67 to 1.38, p = 0.83), myocardial infarction (OR 0.69, 95% CI 0.34 to 1.40, p = 0.31), valve thrombosis (OR 3.11, 95% CI 0.29 to 33.47, p = 0.35), endocarditis (OR 0.71,95% CI 0.35 to 1.48, p = 0.36), aortic valve reintervention (OR 0.93, 95% CI 0.52 to 1.66, p = 0.80), and rehospitalization (OR 0.80, 95% CI 0.52 to 1.02, p = 0.07) compared with SAVR. However, TAVR patients had a higher risk of paravalvular leaks (OR 8.21, 95% CI 4.18 to 16.14, p <0.00001), but lower rates of new-onset atrial fibrillation (OR 0.27,95% CI 0.17 to 0.30, p <0.0001). The rates of permanent pacemaker implantation were comparable from 1 year up to a maximum of 5 years (OR 1.32, 95% CI 0.88 to 1.97, p = 0.18). Lastly, TAVR had a greater effective orifice area (0.10 cm2/m2, 95% CI 0.05 to 0.15, p = 0.0001), but similar transvalvular mean gradients (0.60, 95% CI 3.94 to 2.73, p = 0.72). In conclusion, TAVR patients had similar long-term outcomes compared with SAVR, except for an elevated risk of paravalvular leaks in the TAVR group and increased rates of atrial fibrillation in the SAVR cohort.


Asunto(s)
Estenosis de la Válvula Aórtica , Ensayos Clínicos Controlados Aleatorios como Asunto , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Estenosis de la Válvula Aórtica/cirugía , Estudios de Seguimiento , Complicaciones Posoperatorias/epidemiología , Medición de Riesgo/métodos , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/métodos
16.
EuroIntervention ; 20(8): e504-e510, 2024 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-38629420

RESUMEN

The treatment of coronary artery disease (CAD) in patients with severe aortic valve stenosis (AVS) eligible for transcatheter aortic valve implantation (TAVI) is not supported by clinical evidence, and the role of physiology over anatomy as well as the timing of coronary intervention are not defined. FAITAVI (ClinicalTrials.gov: NCT03360591) is a nationwide prospective, open-label, multicentre, randomised controlled study comparing the angiography-guided versus the physiology-guided coronary revascularisation strategy in patients with combined significant CAD and severe AVS undergoing TAVI. Significant CAD will be defined as coronary stenosis ≥50%, as assessed by visual estimation in vessels ≥2.5 mm. Physiology will be tested by fractional flow reserve (FFR) and instantaneous wave-free ratio (iFR). The study will be conducted at 15 sites in Italy. In the angiography arm, percutaneous coronary intervention (PCI) will be performed either before TAVI, during the TAVI procedure - before or after the valve implantation - or within 1 month±5 days of the valve implantation, left to the operator's decision. In the physiology arm, FFR and iFR will be performed before TAVI, and PCI will be indicated for FFR ≤0.80, otherwise the intervention will be deferred. In case of borderline values (0.81-0.85), FFR and iFR will be repeated after TAVI, with PCI performed when needed. With a sample size of 320 patients, the study is powered to evaluate the primary endpoint (a composite of death, myocardial infarction, stroke, major bleeding, or ischaemia-driven target vessel revascularisation). TAVI indication, strategy and medical treatment will be the same in both groups. After discharge, patients will be contacted at 1, 6, 12 and 24 months after the procedure to assess their general clinical status, and at 12 months for the occurrence of events included in the primary and secondary endpoints. FAITAVI is the first randomised clinical trial to investigate "optimal" percutaneous coronary intervention associated with TAVI in patients with severe AVS and CAD.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Arteria Coronaria , Reserva del Flujo Fraccional Miocárdico , Intervención Coronaria Percutánea , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/cirugía , Estudios Prospectivos , Resultado del Tratamiento , Estudios Multicéntricos como Asunto , Ensayos Clínicos Controlados Aleatorios como Asunto
17.
Int J Cardiol ; 417: 132569, 2024 Sep 19.
Artículo en Inglés | MEDLINE | ID: mdl-39303924

RESUMEN

BACKGROUND: Raphe-type bicuspid aortic valve (BAV) is a potential hostile scenario in trans-catheter aortic valve replacement (TAVR) due to pronounced calcium burden, possibly associated with tapered valve configuration. Trans-Catheter heart valve (THV) sizing strategy (annular vs. supra-annular) is controversial in this valve subtype. OBJECTIVES: To describe the phenotypical characteristics of severe, tapered, raphe-type, BAV stenosis undergoing TAVR and to explore safety and efficacy of modern-generation THVs, analysing the impact of annular and supra-annular sizing strategies on short- and mid-terms outcomes. METHODS: This is a retrospective, multicenter registry enrolling consecutive stenotic Sievers type 1 BAV treated with TAVR. Study population was divided into tapered and non-tapered configuration according to MSCT analysis. Matched comparison between annular and supra-annular sizing groups was performed in tapered population. RESULTS: From January 2016 to June 2023, 897 patients were enrolled. Of them, 696 patients displayed a tapered configuration. Of those, 510 received a THV according to annular sizing. After propensity score matching 186 matched pairs were selected. Technical success (96.2 % vs 94.1 %, OR 1.61 [0.61-4.24], p = 0.34), 30-day device success (83.6 % in both groups, OR 1.42 [0.78-2.57], p = 0.25) and 30-day early safety (71.8 % vs 70.5 %, OR 1.07 [0.68-1.68], p = 0.78) were similar between the annular and supra-annular sizing groups; a higher post-TAVR gradient was observed in supra-annular group, although it was only 2 mmHg mean. At mid-term follow-up, the rate of clinical efficacy was 84.7 %. CONCLUSIONS: TAVR with modern-generation devices is safe and effective for tapered raphe-type BAV, showing comparable results for annular and supra-annular sizing strategies.

18.
JACC Cardiovasc Interv ; 17(14): 1652-1663, 2024 Jul 22.
Artículo en Inglés | MEDLINE | ID: mdl-38749449

RESUMEN

BACKGROUND: Transcatheter aortic valve replacement (TAVR) in patients with bicuspid aortic valve (BAV) stenosis is technically challenging and is burdened by an increased risk of paravalvular regurgitation (PVR). OBJECTIVES: The aim of this study was to identify the incidence, predictors, and clinical outcomes of PVR after TAVR in Sievers type 1 BAV stenosis. METHODS: Consecutive patients with Sievers type 1 BAV stenosis undergoing TAVR with current-generation transcatheter heart valves (THVs) in 24 international centers were enrolled. PVR was graded as none/trace, mild, moderate, and severe according to echocardiographic criteria. The endpoint of major adverse events (MAEs), defined as a composite of all-cause death, stroke, or hospitalization for heart failure, was assessed at the last available follow-up. RESULTS: A total of 946 patients were enrolled. PVR occurred in 423 patients (44.7%)-mild, moderate, and severe in 387 (40.9%), 32 (3.4%), and 4 (0.4%) patients, respectively. Independent predictors of moderate or severe PVR were a larger virtual raphe ring perimeter (adjusted OR: 1.07; 95% CI: 1.02-1.13), severe annular or left ventricular outflow tract calcification (adjusted OR: 5.21; 95% CI: 1.45-18.77), a self-expanding valve (adjusted OR: 9.01; 95% CI: 2.09-38.86), and intentional supra-annular THV positioning (adjusted OR: 3.31; 95% CI: 1.04-10.54). At a median follow-up of 1.3 years (Q1-Q3: 0.5-2.4 years), moderate or severe PVR was associated with an increased risk of MAEs (adjusted HR: 2.52; 95% CI: 1.24-5.09). CONCLUSIONS: After TAVR with current-generation THVs in Sievers type 1 BAV stenosis, moderate or severe PVR occurred in about 4% of cases and was associated with an increased risk of MAEs during follow-up.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Prótesis Valvulares Cardíacas , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Femenino , Factores de Riesgo , Anciano , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Insuficiencia de la Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/mortalidad , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Válvula Aórtica/anomalías , Resultado del Tratamiento , Anciano de 80 o más Años , Incidencia , Factores de Tiempo , Enfermedad de la Válvula Aórtica Bicúspide/cirugía , Enfermedad de la Válvula Aórtica Bicúspide/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/cirugía , Enfermedades de las Válvulas Cardíacas/fisiopatología , Europa (Continente) , Medición de Riesgo , Diseño de Prótesis , Oportunidad Relativa , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/diagnóstico , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/diagnóstico , Estudios Retrospectivos
19.
Heart ; 110(1): 27-34, 2023 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-37414524

RESUMEN

OBJECTIVE: The European Society of Cardiology guidelines have recently defined new cut-offs for pulmonary hypertension (PH) and pulmonary vasculature resistance (PVR; median pulmonary artery pressure (mPAP) >20 instead of 25 mm Hg and PVR >2 instead of 3 Wood unit). The prognostic value of this updated classification after transcatheter aortic valve implantation (TAVI) is unknown. METHODS: 579 consecutive patients treated by TAVI with preprocedural right heart catheterisation evaluation were included. Patients were grouped as: (1) no PH, (2) isolated precapillary/combined (I-PreC/Co) PH and (3) isolated postcapillary PH (I-PoC). All-cause death, cardiovascular death and hospitalisations for heart failure (HF) were evaluated at follow-up. We also analysed the prognostic role of residual postprocedural PH. RESULTS: Out of 579 patients, 299 (52%) had PH according to the new criteria compared with 185 (32%) according to the previous ones. Overall median age was 82 years, while 55.3% patients were male. Patients with PH were more frequently diagnosed with chronic obstructive pulmonary disease and atrial fibrillation and were characterised by higher surgical risk as compared with patients without PH.At a median follow-up of 2.9 years, the presence of PH according to previous definition was associated with worse survival (p<0.001) and HF hospitalisation (p=0.002) rates, irrespective of PVR values. With newer cut-offs, PH was associated with worse outcomes only in patients with increased PVR, while no differences were found between patients with PH and normal PVR values and those without PH. Postprocedural mPAP normalisation was observed in 45% of the cases, but it was associated with improved long-term survival only in the I-PoC PH group. CONCLUSIONS: New ESC PH cut-offs increased the number of PH diagnoses. The presence of PH, particularly in the setting of increased PVR, identify patients at higher risk for postprocedural mortality and rehospitalisation. Normalisation of PH was associated with better survival only in I-PoC group.


Asunto(s)
Estenosis de la Válvula Aórtica , Insuficiencia Cardíaca , Hipertensión Pulmonar , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Anciano de 80 o más Años , Femenino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Hipertensión Pulmonar/diagnóstico , Hipertensión Pulmonar/etiología , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Pronóstico , Resultado del Tratamiento , Factores de Riesgo
20.
Front Cardiovasc Med ; 9: 1056496, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36578836

RESUMEN

Objectives: To assess the impact of conventional transcatheter heart valve (THV) commissural alignment techniques on THV/coronary overlap and coronary access (CA) after transcatheter aortic valve replacement (TAVR) in bicuspid aortic valve (BAV). Background: Specific Evolut Pro/Pro + and Acurate Neo2 THV orientations are associated with reduced neo-commissural overlap with coronary ostia in tricuspid aortic anatomy. Whether standard orientation techniques are effective also in the setting of BAV anatomy has not been studied. Methods: The DA VINCI (Definition of trAnscatheter aortic Valve orIeNtation in biCuspId aortic valve) pilot study is a prospective registry enrolling consecutive patients with severe BAV stenosis undergoing TAVR with last generation supra-annular tall-frame THVs implanted with a cusp overlap view-based commissural alignment. Patients underwent pre- and post-TAVR computed tomography (CT) and coronary angiography. The study endpoint was the rate of favorable THV/coronary overlap, defined as an angle > 40° between the THV commissural post and coronary ostia. Other endpoints were the rates of successful THV alignment with respect to the raphe and of selective CA after TAVR. Moreover, different virtual THV alignment models were tested to identify which one would produce the lower degree of THV/coronary overlap. Results: Thirty-four patients with type 1 BAV with right-left raphe undergoing TAVR (23 with Evolut Pro/Pro + and 11 with Acurate Neo2) were included. At pre-TAVR CT, moderate/severe cusp asymmetry was found in 50% of patients, severe coronary ostia eccentricity was observed in 47.1% for the RCA vs. 8.8% for the LCA (P < 0.007). Correct TVH orientation was achieved in 29 cases. At post-TAVR CT, optimal THV alignment/mild misalignment to the raphe was observed in 86.2%, but a moderate/severe overlap with the coronaries was seen in 13.7% for the RCA and 44.8% for the LCA (P = 0.019). After TAVR, selective RCA cannulation was possible in 82.8% vs. 75.9% for the LCA (P = 0.74), while combined selective CA of both coronaries was possible in less than two-thirds of the patients. Virtual THV alignment in the coronary ostia overlap view assuming a hypothetical circular THV expansion would produce an optimal THV/coronary overlap in almost 90% of cases. Conclusion: Given cusp asymmetry and coronary ostia eccentricity of BAV combined with potential THV asymmetrical expansion, conventional commissural alignment techniques are associated with higher rates of THV misalignment and of moderate/severe neo-commissure overlap with the coronary ostia as compared to tricuspid aortic stenosis, resulting in lower rates of selective CA after TAVR. A modified THV orientation technique based on the coronary ostia overlap view might be preferable in BAV patients.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA