Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 38
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Europace ; 25(1): 112-120, 2023 02 08.
Artículo en Inglés | MEDLINE | ID: mdl-36036679

RESUMEN

AIMS: The safety and efficacy of leadless intracardiac-permanent pacemaker (L-PM) have been demonstrated in multiple clinical trials, but data on comparisons with conventional transvenous-permanent pacemaker (T-PM) collected in a consecutive, prospective fashion are limited. The aim of this analysis was to compare the rate and the nature of device-related complications between patients undergoing L-PM vs. T-PM implantation. METHODS AND RESULTS: Prospective, multicentre, observational project enrolling consecutive patients who underwent L-PM or T-PM implantation. The rate and nature of device-related complications were analysed and compared between the two groups. Individual 1:1 propensity matching of baseline characteristics was performed. A total of 2669 (n = 665 L-PM) patients were included and followed for a median of 39 months, L-PM patients were on average older and had more co-morbidities. The risk of device-related complications at 12 months was significantly lower in the L-PM group (0.5% vs. 1.9%, P = 0.009). Propensity matching yielded 442 matched pairs. In the matched cohort, L-PM patients trended toward having a lower risk of overall device-related complications (P = 0.129), had a similar risk of early complications (≤30 days) (P = 1.000), and had a significantly lower risk of late complications (>30 days) (P = 0.031). All complications observed in L-PM group were early. Most (75.0%) of complications observed in T-PM group were lead- or pocket-related. CONCLUSION: In this analysis, the risk of device-related complications associated with L-PM implantation tended to be lower than that of T-PM. Specifically, the risk of early complications was similar in two types of PMs, while the risk of late complications was significantly lower for L-PM than T-PM.


Asunto(s)
Arritmias Cardíacas , Marcapaso Artificial , Humanos , Resultado del Tratamiento , Diseño de Equipo , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Arritmias Cardíacas/etiología , Marcapaso Artificial/efectos adversos , Factores de Tiempo
2.
J Cardiovasc Electrophysiol ; 33(7): 1567-1575, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35634866

RESUMEN

INTRODUCTION: Left ventricular (LV) lead optimal positioning is one of the most important determinants of cardiac resynchronization therapy (CRT) success. LV quadripolar active fixation (QAF) leads have been designed to ensure stable LV pacing in the target area and reduce the likelihood of phrenic nerve stimulation (PNS). The aim of this analysis is to compare performances, safety, and clinical outcomes of QAF with those of quadripolar passive fixation leads (QPL) and bipolar active fixation (BAF) leads in a real-world cohort of CRT patients. METHODS AND RESULTS: This retrospective analysis compared the procedure and follow-up data of 117 QAF included in the One Hospital ClinicalService project from nine Italian hospitals with two historical cohorts of 261 BAF and 124 QPL. QAF enabled basal pacing more frequently than QPL (24.1% vs. 6.5%, p < .001) but not differently from BAF (p = .981). At implant, mean QAF LV myocardial threshold (LVMT) was 1.21 ± 0.8 V at 0.4 ms, not different from that of BAF (p = .346) and QPL (p = .333). At a median follow-up of 22 months, LVMT was 1.37 ± 0.90 V (p = .036 vs. implant). Acute LV lead dislodgment occurrence was low in all cohorts: 1 (0.9%) in QAF, 4 in BAF (1.5%), and none (0.0%) in QPL. During follow-up, total LV-related complication rate was lower in QAF (0.5/100 patient-years) than in BAF (4.2/100 patient-years, p = .014) and QPL (3.6/100 patient-years, p = .055). QAF, BAF, and QPL annual rate of heart failure hospitalization were respectively 6.1/100 patient-years, 2.5/100 patient-years (p = .081), and 3.6/100 patient-years (p = .346). CRT responders' rate in QAF was 69.9%, with no difference in comparison to BAF (p = .998) and QPL (p = .509). During follow-up, mean left ventricular ejection fraction (LVEF) of QAF increased from 31.8 ± 10.1% to 40.3 ± 10.7% (p < .001). The average degree of echocardiographic response (ΔLVEF) did not differ between QAF and other cohorts; however, LVEF CRT responder's distribution of QAF differs from those of BAF (p = .003) and QPL (p = .022), due to a higher percentage of super-responders. CONCLUSIONS: QAF with short interelectrode spacing resulted in non-inferior clinical outcomes and CRT responders' rate in comparison to BAF and QPL, while reducing complication rate during follow-up and increasing the possibilities of electronic repositioning to manage PNS or to optimize resynchronization therapy.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Terapia de Resincronización Cardíaca/efectos adversos , Terapia de Resincronización Cardíaca/métodos , Dispositivos de Terapia de Resincronización Cardíaca , Estudios de Seguimiento , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Humanos , Estudios Retrospectivos , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda
3.
Int J Clin Pract ; 75(3): e13820, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33164319

RESUMEN

OBJECTIVE: The MINERVA trial showed that in pacemaker patients with atrial fibrillation (AF) history, DDDRP pacing combining three algorithms - (a) atrial antitachycardia pacing with Reactive ATP enabled, (b) atrial preventive pacing and (c) managed ventricular pacing (MVP)-may effectively delay progression to persistent/permanent AF compared with standard DDDR pacing. We performed a comparative non-randomised evaluation to evaluate if Reactive ATP can be the main driver of persistent/permanent AF reduction independently on preventive pacing. METHODS: Thirty-one centres included consecutive dual-chamber pacemaker patients with AF history. Reactive ATP was programmed in all patients while preventive atrial pacing was not enabled. These patients were compared with the three groups of MINERVA randomised trial (Control DDDR, MVP, and DDDRP). The main endpoint was the incidence of AF longer than 7 consecutive days. RESULTS: A total of 146 patients (73 years old, 54% male) were included and followed for a median observation period of 31 months. The 2-year incidence of AF > 7 days was 12% in the Reactive ATP group, very similar to that found in the DDDRP arm of the MINERVA trial (13.8%, P = .732) and significantly lower than AF incidence found in the MINERVA Control DDDR arm (25.8%, P = .012) and in the MINERVA MVP arm (25.9%, P = .025). CONCLUSIONS: In a real-world population of dual-chamber pacemaker patients with AF history, the use of Reactive ATP is associated with a low incidence of persistent AF, highlighting that the positive results of the MINERVA trial were related to the effectiveness of Reactive ATP rather than to preventive pacing.


Asunto(s)
Fibrilación Atrial , Marcapaso Artificial , Anciano , Fibrilación Atrial/prevención & control , Estimulación Cardíaca Artificial , Femenino , Atrios Cardíacos , Humanos , Incidencia , Masculino , Resultado del Tratamiento
4.
J Cardiovasc Electrophysiol ; 30(6): 854-864, 2019 06.
Artículo en Inglés | MEDLINE | ID: mdl-30827041

RESUMEN

INTRODUCTION: The recently developed second-generation subcutaneous implantable cardioverter defibrillator (S-ICD) and the intermuscular two-incision implantation technique demonstrate potential favorable features that reduce inappropriate shocks and complications. However, data concerning large patient populations are lacking. The aim of this multicentre prospective study was to evaluate the safety and outcome of second-generation S-ICD using the intermuscular two-incision technique in a large population study. METHODS AND RESULTS: The study population included 101 consecutive patients (75% male; mean age, 45 ± 13 years) who received second-generation S-ICD (EMBLEM; Boston Scientific, Marlborough, MA) implantation using the intermuscular two-incision technique as an alternative to the standard implantation technique. Twenty nine (29%) patients were implanted for secondary prevention. Twenty four (24%) patients had a previously implanted transvenous ICD. All patients were implanted without any procedure-related complications. Defibrillation testing was performed in 80 (79%) patients, and ventricular tachycardia was successfully converted at less than or equal to 65 J in 98.75% (79/80) of patients without pulse generator adjustments. During a median follow-up of 21 ± 10 months, no complications requiring surgical revision or local or systemic device-related infections were observed. Ten patients (9.9%) received appropriate and successful shocks for ventricular arrhythmias. Three (2.9%) patients experienced inappropriate shocks due to oversensing the cardiac signal (n = 1), noncardiac signal (n = 1), and a combination of both cardiac and noncardiac signals (n = 1), with one patient requiring device explantation. No patients required device explantation due to antitachycardia pacing indications. CONCLUSIONS: According to our multicentre study, second-generation S-ICD implanted with the intermuscular two-incision technique is an available safe combination and appears to be associated with a low risk of complications, such as inappropriate shocks.


Asunto(s)
Arritmias Cardíacas/terapia , Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Sistema de Conducción Cardíaco/fisiopatología , Frecuencia Cardíaca , Implantación de Prótesis/instrumentación , Prevención Secundaria/instrumentación , Potenciales de Acción , Adolescente , Adulto , Anciano , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatología , Remoción de Dispositivos , Cardioversión Eléctrica/efectos adversos , Femenino , Humanos , Italia , Masculino , Persona de Mediana Edad , Falla de Prótesis , Implantación de Prótesis/efectos adversos , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
5.
Pacing Clin Electrophysiol ; 42(7): 989-997, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-30997679

RESUMEN

BACKGROUND: In addition to the Evolution RL sheath, tools by Cook Medical (Bloomington, IN, USA), supporting lead extraction (LE), are available. Data on their use are not reported in detail in previous studies. Moreover, data regarding outcome are lacking. The aim was to evaluate the safety and effectiveness of the Evolution sheath (Evolution RL and Evolution Shortie, Cook Medical) by using a stepwise approach with the available extraction tools and the outcome. METHODS: A total of 393 leads in 198 consecutive patients were removed with the Evolution RL sheath and ancillary tools using a stepwise approach. RESULTS: The main indication for LE was infection in 125 (63.1%) cases. The mean implant duration was 95.4 ± 59.7 months. According to our stepwise approach, the Evolution Shortie RL sheath was used in all cases and complete LE was achieved in 24 (12.2%) cases. The Evolution RL was used in 174 (87.8%) cases and the SteadySheath Evolution tissue stabilization sheath (Cook Medical) in 87 (44%) because of tenacious fibrosis anchored targeted leads. Compression coil (OneTie, Cook Medical) was used in 141 (71%) cases. Complete procedural success rate, clinical success rate, and lead removal with clinical success rate were 97%, 99%, and 99.5%, respectively. One major complication (0.5%) and 10 (5%) minor complications were encountered. During a mean time follow-up of 12 ± 9 months, 14 (7%) patients died. Predictors of mortality included impaired renal function (HR 5.7; 95% CI 1.9-17.6; P = 0.002), extraction because of infection (hazard ratio [HR] 4.0; 95% confidence interval [CI] 1-18.1; P = 0.045), and diabetes (HR 3.2; 95% CI 1.1-9.8; P = 0.036). CONCLUSIONS: Lead extraction using the Evolution RL bidirectional rotational mechanical sheath and ancillary tools in a systematic stepwise approach was effective and safe.


Asunto(s)
Remoción de Dispositivos/instrumentación , Electrodos Implantados , Marcapaso Artificial , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Niño , Ecocardiografía Transesofágica , Diseño de Equipo , Historia del Siglo XVII , Humanos , Seguridad del Paciente , Factores de Riesgo , Ultrasonografía Intervencional
6.
Europace ; 20(5): 829-834, 2018 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-28339758

RESUMEN

Aims: The aim of this prospective multicentre study is to evaluate safety and efficacy of the new bidirectional rotational mechanical lead extraction (LE) sheath (Evolution RL, Cook Medical, USA) in chronically implanted leads (>1-year-old leads). Methods and results: Between September 2013 and June 2016, a total of 238 leads in 124 consecutive patients were removed by using the new Evolution RL rotational mechanical sheath. Indications for LE were cardiac device infection in 63 (50.8%) cases, lead malfunction in 41 (33.1%), upgrade in 1 (0.8%) case and for other reasons in the remaining 19 cases (15.3%). Ninety-one leads (38.2%) were implantable cardioverter defibrillator leads (81 dual coil vs. 10 single coil), 38 (16%) right ventricular leads, 86 (36.1%) right atrial leads, and 23 (9.7%) coronary sinus leads. The mean implant duration was 92.2 ± 52.9 months (range 12-336). 91.6% of the leads (218/238) were extracted completely with the Evolution RL alone, with the complete success rate rising to 98.7% (235/238 leads) with combined use of a snare. Overall clinical success rate was 100%. No Evolution sheath-related complications were noted. There were no deaths or major complications. Five minor complications (4%) were encountered. In cases of companion leads no wrapping or lead damage were observed. Conclusion: On the basis of our prospective multicentre study, the new hand-powered bidirectional rotational mechanical LE sheath is an effective and safe tool for the extraction of chronically implanted leads without major complications and lead wrapping or lead damage.


Asunto(s)
Desfibriladores Implantables/efectos adversos , Remoción de Dispositivos , Marcapaso Artificial/efectos adversos , Infecciones Relacionadas con Prótesis/cirugía , Anciano , Remoción de Dispositivos/efectos adversos , Remoción de Dispositivos/instrumentación , Remoción de Dispositivos/métodos , Femenino , Humanos , Italia , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Sistema de Registros/estadística & datos numéricos , Resultado del Tratamiento
7.
Pacing Clin Electrophysiol ; 40(3): 278-285, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-27943358

RESUMEN

BACKGROUND: The traditional technique for subcutaneous implantable cardioverter defibrillator (S-ICD) implantation, which involves three incisions and a subcutaneous pocket, is associated with possible complications, including inappropriate interventions. The aim of this prospective multicenter study was to evaluate the efficacy and safety of an alternative intermuscular two-incision technique for S-ICD implantation. METHODS: The study population included 36 consecutive patients (75% male, mean age 44 ± 12 years [range 20-69]) who underwent S-ICD implantation using the intermuscular two-incision technique. This technique avoids the superior parasternal incision for the lead placement and consists of creating an intermuscular pocket between the anterior surface of the serratus anterior and the posterior surface of the latissimus dorsi muscles instead of a subcutaneous pocket. RESULTS: All patients were successfully implanted in the absence of any procedure-related complications with a successful 65-J standard polarity defibrillation threshold testing, except in one, who received a second successful shock after pocket revision. During a mean follow-up of 10 months (range 3-30), no complications requiring surgical revision were observed. At device interrogation, stable sensing without interferences was observed in all patients. Two patients (5.5%) experienced appropriate and successful shock on ventricular fibrillation and in four patients (11%), a total of seven nonsustained self-terminated ventricular tachycardias were correctly detected. No inappropriate interventions were observed. CONCLUSIONS: Our experience suggests that the two-incision intermuscular technique is a safe and efficacious alternative to the current technique for S-ICD implantation that may help reducing complications including inappropriate interventions and offer a better cosmetic outcome, especially in thin individuals.


Asunto(s)
Músculos de la Espalda/cirugía , Desfibriladores Implantables , Insuficiencia Cardíaca/prevención & control , Implantación de Prótesis/métodos , Sistema de Registros , Adulto , Anciano , Femenino , Humanos , Italia , Masculino , Persona de Mediana Edad , Implantación de Prótesis/efectos adversos , Estudios Retrospectivos , Resultado del Tratamiento , Adulto Joven
8.
Heart Fail Clin ; 13(1): 225-232, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-27886927

RESUMEN

This review discusses the state of the art of knowledge to help decision making in patients who are candidates for cardiac resynchronization therapy (CRT) and to analyze the long-term total and cardiac mortality, sudden death, and CRT with a defibrillator intervention rate, as well as the evolution of echocardiographic parameters in patients with a left ventricular (LV) ejection fraction of greater than 50% after CRT implantation. Owing to normalization of LV function in super-responders, the need for a persistent defibrillator backup is also considered.


Asunto(s)
Terapia de Resincronización Cardíaca/métodos , Cardioversión Eléctrica/instrumentación , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/terapia , Disfunción Ventricular Izquierda/diagnóstico por imagen , Terapia de Resincronización Cardíaca/efectos adversos , Toma de Decisiones Clínicas/métodos , Ecocardiografía , Cardioversión Eléctrica/estadística & datos numéricos , Medicina Basada en la Evidencia , Insuficiencia Cardíaca/fisiopatología , Humanos , Selección de Paciente , Recuperación de la Función , Análisis de Supervivencia , Resultado del Tratamiento , Disfunción Ventricular Izquierda/etiología , Disfunción Ventricular Izquierda/mortalidad , Función Ventricular Izquierda
9.
Europace ; 16(3): 363-71, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24189477

RESUMEN

AIMS: To evaluate the long-term changes of clinical and echocardiographic parameters, the incidence of cardiac events and parameters associated with late cardiac events in 'super-responders' to cardiac resynchronization therapy (CRT) with [CRT defibrillator (CRT-D)] or without defibrillator back-up. METHODS AND RESULTS: In all consecutive patients treated with CRT in two Italian centres (Trieste and Udine) with left ventricular ejection fraction (LVEF) ≤0.35 at implantation (Timp) and LVEF > 0.50 1 and/or 2 years (Tnorm) after implantation, the long-term outcome and the evolution of echocardiographic parameters were assessed; factors associated with a higher risk of cardiac events, defined as hospitalization or death for heart failure (HF), sudden death, or CRT-D appropriate interventions, were also analysed. Among the 259 patients evaluated, 62 (24%) had LVEF ≥ 0.50 at Tnorm (n = 44 with at 1 year, n = 18 at 2 years). During a mean follow-up of 68 ± 30 months, one cardiac death (for HF) and eight cardiovascular events (two hospitalization for HF and six appropriate CRT-D interventions) occurred. At the last echo evaluation (Tfup) performed 51 ± 26 months after Timp, LVEF was <0.50 in five patients (>0.45 in four of them). At univariable analysis, only LV end-systolic volume evaluated at Tfup was associated with a higher risk of cardiac events during follow-up. CONCLUSION: In 'super-responders' to CRT long-term outcome is excellent. However, cardiac events, mainly CRT-D appropriate interventions, can occur despite the persistence of LVEF > 0.50. Early identification of these patients is still an unsolved issue.


Asunto(s)
Terapia de Resincronización Cardíaca/mortalidad , Muerte Súbita Cardíaca/epidemiología , Desfibriladores Implantables/estadística & datos numéricos , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/prevención & control , Mortalidad Hospitalaria , Anciano , Terapia Combinada , Comorbilidad , Muerte Súbita Cardíaca/prevención & control , Femenino , Humanos , Italia , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Prevalencia , Pronóstico , Factores de Riesgo , Resultado del Tratamiento
10.
Pacing Clin Electrophysiol ; 37(12): 1610-8, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25113510

RESUMEN

BACKGROUND: Atrial fibrillation (AF) is common in patients with cardiac implantable electronic devices (CIED) and has been associated with an increased stroke risk. The aim of our project was to assess the clinical value of a web-based application, Discovery Link AFinder, in improving AF detection in CIED patients. METHODS AND RESULTS: Seven Italian hospitals performed an observational study consisting of four phases. During phase 1, expert nurses and cardiologists prospectively followed-up CIED patients via in-hospital examinations and remote monitoring, and classified clinically relevant events, particularly AF occurrence. During phase 2, Discovery Link AFinder was exploited to identify patients who had suffered AF in the previous 12 months through the systematic scanning of device data remote transmissions. Phases 3 and 4 were repetitions of phases 1 and 2, respectively, and were implemented 6 months after the previous phases. A total of 472 consecutive patients were included in phase 1; AF occurred in 170 patients, 61 of whom were identified as new AF patients. Evidence of AF during this phase prompted prescription of oral anticoagulation (OAC) therapy in 30 patients. In phase 2, AFinder uncovered new AF, unidentified in phase 1, in 54 patients and prompted implementation of OAC therapy in 11 patients. During phase 3, 30 new AF patients were identified by means of remote monitoring, while during phase 4, a further three AF patients were identified by AFinder only. CONCLUSIONS: The AFinder web-based software, applied on top of standard in-hospital and remote monitoring, improved AF detection and enabled OAC treatment to be undertaken.


Asunto(s)
Fibrilación Atrial/diagnóstico , Desfibriladores Implantables , Aplicaciones Móviles , Monitoreo Ambulatorio , Marcapaso Artificial , Complicaciones Posoperatorias/diagnóstico , Implantación de Prótesis , Mejoramiento de la Calidad , Tecnología de Sensores Remotos , Anciano , Femenino , Humanos , Masculino
11.
J Cardiovasc Med (Hagerstown) ; 23(1): 42-48, 2022 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-34392257

RESUMEN

AIMS: Cardiac resynchronization therapy (CRT) is indicated in patients with systolic heart failure (HF), severe left ventricle (LV) dysfunction and interventricular dyssynchrony.In prospective observational research, we aimed to evaluate whether CRT-induced LV reverse remodelling and occurrence of ventricular arrhythmias (VT/VF) independently contribute to prognosis in patients with CRT defibrillators (CRT-D). METHODS: In 95 Italian cardiological centres, after a screening period of 6 months, patients were categorized according to VT/VF occurrence and CRT response, defined as LV end-systolic volume relative reduction >15% or LV ejection fraction absolute increase >5%. The main endpoint was death or HF hospitalizations. RESULTS: Among 1308 CRT-D patients (80% male, mean age 66 years), at 6 months, follow-up 71% were identified as CRT responders and 12% experienced appropriate VT/VF detections. The main endpoint was significantly and independently associated with previous myocardial infarction, New York Heart Association Class, VT/VF occurrence and with CRT response. CRT nonresponder patients who suffered VT/VF in the screening period had a risk of death or HF hospitalizations [HR = 7.82, 95% confidence interval (CI) = 3.95-15.48] significantly (P < 0.001) higher than CRT responders without VT/VF occurrence. This risk is mitigated without VT/VF occurrence (HR = 3.47, 95% CI = 2.03-5.91, P < 0.001) or in case of CRT response (HR = 3.11, 95% CI = 1.44-6.72, P = 0.004). CONCLUSION: Our data show that both CRT response and occurrence of VT/VF independently contribute to the risk of death or HF-related hospitalizations in CRT-D patients. Early VT/VF occurrence may be identified as a marker of disease severity than can be mitigated by CRT response both in terms of all-cause mortality and long-term VT/VF onset. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier: NCT00147290 and NCT00617175.


Asunto(s)
Arritmias Cardíacas/mortalidad , Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca/mortalidad , Hospitalización , Anciano , Arritmias Cardíacas/terapia , Femenino , Insuficiencia Cardíaca/terapia , Humanos , Masculino , Pronóstico , Estudios Prospectivos , Remodelación Ventricular
12.
Heart Rhythm O2 ; 2(6Part B): 840-847, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34988535

RESUMEN

BACKGROUND: Antiarrhythmic therapy for recurrent ventricular arrhythmias in patients who have undergone catheter ablation, and in whom amiodarone and/or beta-blockers were ineffective or contraindicated, is a controversial issue. OBJECTIVE: The present study sought to evaluate the efficacy and tolerability of oral procainamide in patients with recurrent ventricular arrhythmias when the standard therapy strategy had failed. METHODS: All patients treated with procainamide for recurrent ventricular tachycardia (VT) or ventricular fibrillation (VF) in our institution between January 2010 and May 2019 were enrolled. The primary endpoint was the total number of implantable cardioverter-defibrillator (ICD) interventions after the beginning of procainamide therapy. Secondary endpoints were the total number of VTs and VFs recorded on the ICDs' controls and discontinuation of therapy. The events occurring during procainamide treatment were compared with a matched-duration period before the initiation of therapy with procainamide. Patients therefore served as self-controls. RESULTS: A total of 34 consecutive patients (32 male, 94.1%; mean age 74.4 ± 9.7 years) were included in the retrospective analysis. The mean time of procainamide treatment was 12.9 ± 13.7 months (median 9 [2-20] months). The mean dose of procainamide was 1207 ± 487 mg/day. Procainamide therapy significantly decreased ICD interventions (median 5 [0-22.5] vs 15.5 [3-32.25], P < .05). Procainamide also decreased the total number of VT/VF episodes (median 5.5 [0.75-30] vs 19 [7.5-30], P < .05). Only 3 patients (8.8%) presented severe side effects (dyspnea or hypotension), requiring discontinuation of therapy. CONCLUSION: Oral procainamide was associated with a significant decrease in ICD therapies and ventricular arrhythmias, showing an acceptable profile of tolerability.

13.
Europace ; 12(2): 202-9, 2010 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-19903671

RESUMEN

AIMS: To assess the impact on clinical practice of the major published studies, we report the information collected by the Italian Pacemaker Registry (IPR) in the quinquennium 2003-07. METHODS AND RESULTS: The IPR collected prospectively main epidemiological, clinical, and electrocardiographic data of patients treated by pacemaker (PM) in Italy on the basis of European PM Card. The number of reported PMs in Italy was 30,820 in 2003, 32,047 in 2004, 31,870 in 2005, 31,813 in 2006, and 31,146 in 2007, respectively. The median age was 79 years in all 5 years. Among the atrio-ventricular (AV) conduction defects, third-degree AV block was the most common occurrence. Of the sick sinus syndrome (SSS), sinus node dysfunction involved the majority of cases followed by bradycardia-tachycardia syndrome. Year-over-year percentages among the different indications remained stable. Syncope and dizzy spells were by far the most common symptoms. Dual-chamber pacing showed an increasing utilization in all the examined years. CONCLUSION: Italian PM Registry data for the study period reveal a stable pattern of PM utilization and indications. A higher use of dual-chamber pacing in comparison to single-chamber pacing was reported for all indications, despite inconclusive data of the major randomized trials.


Asunto(s)
Bloqueo Atrioventricular/terapia , Bloqueo de Rama/terapia , Marcapaso Artificial/estadística & datos numéricos , Marcapaso Artificial/tendencias , Sistema de Registros , Síndrome del Seno Enfermo/terapia , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Bloqueo Atrioventricular/epidemiología , Bloqueo Atrioventricular/fisiopatología , Bloqueo de Rama/epidemiología , Bloqueo de Rama/fisiopatología , Estimulación Cardíaca Artificial/métodos , Niño , Preescolar , Desfibriladores Implantables/clasificación , Desfibriladores Implantables/estadística & datos numéricos , Desfibriladores Implantables/tendencias , Electrocardiografía , Humanos , Lactante , Recién Nacido , Italia/epidemiología , Persona de Mediana Edad , Marcapaso Artificial/clasificación , Estudios Prospectivos , Estudios Retrospectivos , Síndrome del Seno Enfermo/epidemiología , Síndrome del Seno Enfermo/fisiopatología , Adulto Joven
14.
J Am Heart Assoc ; 9(13): e017122, 2020 07 07.
Artículo en Inglés | MEDLINE | ID: mdl-32441548

RESUMEN

Background Northern Italy is one of the epicenters of severe acute respiratory syndrome coronavirus 2 (SARS-CoV 2) pandemic in Europe. The impact of the pandemic and the consequent lockdown on medical emergencies other than those SARS-CoV 2 pandemic related is largely unknown. The aim of this study was to analyze the epidemiologic impact of coronavirus disease 2019 pandemic on hospital admission for severe emergent cardiovascular diseases (SECDs) in a single Northern Italy large tertiary referral center. Methods and Results We quantified SECDs admissions to the Cardiology Division of Udine University Hospital between March 1, 2020 and March 31, 2020 and compared them with those of the same time frame during 2019. Compared with March 2019, we observed a significant reduction in all SECDs admissions: -30% for ST-segment-elevation acute coronary syndromes, -66% for non-ST-segment-elevation acute coronary syndromes and -50% for severe bradyarrhythmia. Conclusions A significant decrease in all SECDs admissions has been observed during the SARS-CoV 2. pandemic and was unlikely caused by a reduction in the incidence of cardiovascular diseases. Fear of contagion may have contributed to the unpredictable drop of SECDs. Social education about early recognition of symptoms of life-threatening cardiac conditions requiring appropriate care in a timely fashion may help to reduce this counterproductive phenomenon.


Asunto(s)
Enfermedades Cardiovasculares/etiología , Infecciones por Coronavirus/complicaciones , Urgencias Médicas , Servicio de Urgencia en Hospital/estadística & datos numéricos , Pandemias , Admisión del Paciente/tendencias , Neumonía Viral/complicaciones , Anciano , Betacoronavirus , COVID-19 , Infecciones por Coronavirus/epidemiología , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Italia/epidemiología , Masculino , Persona de Mediana Edad , Neumonía Viral/epidemiología , Estudios Retrospectivos , SARS-CoV-2
15.
Europace ; 11(4): 465-75, 2009 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-19136490

RESUMEN

AIMS: Several studies have demonstrated the life-saving role of implantable cardioverter-defibrillator (ICD) therapy. In order to evaluate the effects of major trials in clinical practice, we report the clinical data of patients enrolled in the Italian ICD Registry for the years 2005-07. METHODS AND RESULTS: The Registry collects prospectively national ICD implantation activity on the basis of EURID Card. The number of ICDs per million of inhabitants was 180.6 in the year 2005, 192.5 in the year 2006, and 220.6 in the year 2007 (P = 0.02). The median age was 69 years for all 3 years considered. Implantable cardioverter-defibrillator implantation for primary prevention concerned 4692 patients in 2005 (44.2%), 5938 patients in 2006 (52.2%), 7324 patients in 2007 (55.7%) and for secondary prevention 5921 patients in 2005 (55.8%), 5447 patients in 2006 (47.8%), and 5828 patients in 2007 (44.3%). Single-chamber ICDs were implanted in 30.9, 31.0, and 28.5% of patients, dual chamber ICDs in 31.9, 31.5, and 31.7%, and biventricular ICDs in 37.2, 37.5, and 39.8%, respectively. CONCLUSION: The ICD implantation rate in Italy increased significantly in the period 2005-07. The registry showed a significant increase in prophylactic and biventricular ICD use, reflecting a favourable adherence to trials and guidelines in the clinical practice.


Asunto(s)
Arritmias Cardíacas/terapia , Desfibriladores Implantables/estadística & datos numéricos , Desfibriladores Implantables/tendencias , Sistema de Registros/estadística & datos numéricos , Anciano , Antiarrítmicos/uso terapéutico , Arritmias Cardíacas/fisiopatología , Estudios de Cohortes , Muerte Súbita Cardíaca/prevención & control , Electrocardiografía , Femenino , Adhesión a Directriz , Humanos , Italia , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Estudios Retrospectivos , Volumen Sistólico/fisiología , Disfunción Ventricular Izquierda/fisiopatología
16.
Pacing Clin Electrophysiol ; 32(4): 434-45, 2009 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-19335851

RESUMEN

BACKGROUND: Previous studies have demonstrated the lifesaving role of an implantable cardioverter-defibrillator (ICD) in high-risk patients with genetic arrhythmogenic diseases. AIM: To evaluate the clinical data of patients with hypertrophic cardiomyopathy (HCM), arrhythmogenic right ventricular cardiomyopathy (ARVD/C), idiopathic ventricular arrhythmia (IDIO-VA) including Brugada syndrome, short QT syndrome, and long QT syndrome (LQT) enrolled in the Italian ICD Registry in the years 2001-6. METHODS: The survey collected prospectively clinical data and technical characteristics of ICD implants on the basis of EURID form. RESULTS: The number of patients was 1,274 in the HCM group, 520 in the ARVD/C group, 460 in the IDIO-VA group, and 245 in the LQT group. Primary prevention involved 29.5% of patients in the HCM group, 15.9% in the ARVD/C group, 16.9% in the IDIO-VA group, and 16.6% in the LQT group, respectively. Ventricular tachycardia and ventricular fibrillation were reported in 49.0% and 24.8% in the HCM group, 72.9% and 20.0% in the ARVD/C group, 48.2% and 42.9% in the IDIO-VA group, and 21.2% and 61.6% in the LQT group, respectively. Single-, dual-, and triple-chamber ICDs were implanted in 41.5%, 47.6%, and 10.9% in the HCM group; 57.9%, 36.7%, and 5.4% in the ARVD/C group; 55.0%, 45.0%, and 0% in the IDIO-VA group; and 57.4%, 42.6%, and 0% in LQT group, respectively. CONCLUSION: ICD therapies in the years 2001-6 for patients with inherited arrhythmia syndromes were utilized in Italy in a still-limited number of patients. Secondary prevention represented the major indication for ICD implant and the majority of patients were treated by single-chamber ICDs.


Asunto(s)
Arritmias Cardíacas/epidemiología , Arritmias Cardíacas/prevención & control , Desfibriladores Implantables/estadística & datos numéricos , Sistema de Registros , Arritmias Cardíacas/genética , Femenino , Predisposición Genética a la Enfermedad/genética , Humanos , Italia/epidemiología , Masculino , Persona de Mediana Edad , Medición de Riesgo , Factores de Riesgo , Resultado del Tratamiento
17.
Int J Cardiol Heart Vasc ; 22: 92-95, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30671534

RESUMEN

BACKGROUND: Non-sustained ventricular tachycardia (NSVT) can occur asymptomatically and can be incidentally detected in the internal records of pacemakers (PM). The clinical value of NSVT in the population of PM patients is still uncertain.Our aim was to assess the prevalence of NSVT detected by remote PM control, to describe the clinical and demographic characteristics of patients with NSVT, and to assess the prognostic significance of NSVT in terms of both overall and cardiovascular mortality. METHODS: Consecutive patients followed with PM remote interrogations from September 2010 to December 2015 were included. The transmissions pertaining to the first 12 months of remote control were analysed and the patients were divided by those presenting NSVT and those without NSVT. The two groups were compared in terms of total mortality and cardiovascular mortality based on the administrative data provided by the regional administration of the Italian National Health System. RESULTS: The prevalence of NSVT in 408 patients (62% males, mean age 75.6; SD 10.6 years old) was 21% in a year. During a mean follow-up duration of 44 months, NSVT did not emerge as independently associated with overall mortality, but was associated with cardiovascular mortality in a competing risk regression model with older age, male gender, diabetes, chronic renal insufficiency, ischemic cardiomyopathy and chronic obstructive pulmonary disease. CONCLUSIONS: We show that NSVT episodes recorded by remote control in a PM population are independently associated with cardiovascular mortality with possible implications for risk stratification and therapeutic options.

18.
J Am Heart Assoc ; 8(15): e012759, 2019 08 06.
Artículo en Inglés | MEDLINE | ID: mdl-31340695

RESUMEN

Background Implantable cardioverter-defibrillators (ICDs) are widely employed for the prevention of sudden cardiac death. Despite technological improvements, patients often need to undergo generator replacement, which entails the risk of periprocedural complications. Our aim was to estimate the service life of ICDs over a 10-year interval and to assess the main causes of replacement on the basis of data from the National ICD Registry of the Italian Society of Arrhythmology and Cardiac Pacing (AIAC). Methods and Results The registry includes data from over 400 hospitals in Italy. We included all patients who underwent device replacement from calendar years 2007 to 2016. The median service life of the ICDs and its trend over the years was estimated across the 3 types of devices (single-chamber, dual-chamber, cardiac resynchronization therapy defibrillator) and the indication to implantation. The causes of replacement were also analyzed. We included 29 158 records from 27 676 patients (80.9% men; mean age at device replacement 65.8±12.0 years). The median service life was 57.3 months (interquartile range 27.8 months). Over the years, service life showed an increasing trend. The majority of patients underwent elective replacement because of battery end of life, and over the years there was a significant reduction of replacement for recalls, erosion/infections, and cardiac resynchronization therapy upgrading. Conclusions Our data from a large single-nation population showed that the trend of ICD service life, independently from ICD type, indication, and settings, significantly improved over time. Moreover, there was a striking reduction of interventions for upgrading and infection/erosion. This favorable trend has important clinical, organizational, and financial implications.


Asunto(s)
Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Anciano , Femenino , Estudios de Seguimiento , Humanos , Italia , Masculino , Persona de Mediana Edad , Sistema de Registros , Factores de Tiempo
19.
Europace ; 10(9): 1085-90, 2008 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-18667447

RESUMEN

AIMS: To compare clinical characteristics, procedure complexity, acute and long-term outcome of 'ablate and pace' (A&P) with pulmonary vein isolation (PVI) in patients with drug-refractory atrial fibrillation (AF). So far, only few small studies have compared the two procedures. METHODS AND RESULTS: We analysed retrospectively a cohort of symptomatic consecutive patients with drug-refractory AF. Group 1 included 100 patients treated with A&P and Group 2 included 144 patients treated with PVI. Group 1 patients were older (74 +/- 8 vs. 56 +/- 9 years; P < 0.0001), had lower left ventricular ejection fraction (50 +/- 13% vs. 59 +/- 7%; P < 0.05), and a lower prevalence of paroxysmal AF (46% vs. 65%; P < 0.05). Acute success was not statistically different (98% vs. 92.3%, P = ns). Group 1 patients had shorter procedure time and lower radiation exposure with respect to Group 2 patients (70 +/- 15 vs. 204 +/- 58 min, and 8 +/- 4 vs. 57 +/- 22 min; P < 0.0001, respectively). After a median follow-up of 29 months (I, III quartile; 15, 40 months) vs. 25 months (I, III quartile; 8, 36 months) (P = ns), all the patients in Group 1 were free of symptomatic AF, while 113 patients (79%) of Group 2 were in stable sinus rhythm (P < 0.0001). Persistent or permanent AF has been documented in 58 patients (58%) of Group 1 vs. 11 (8%) of Group 2 (P < 0.0001). CONCLUSION: In this series (i) patients treated with A&P and PVI for drug-refractory AF showed significant differences in clinical profile; (ii) A&P is a shorter and less complex procedure, but is associated with a higher rate of persistent AF; (iii) symptomatic recurrences of paroxysmal AF were more frequent in PVI group. Randomized studies appear necessary to identify the best strategy in selected cases.


Asunto(s)
Fibrilación Atrial/cirugía , Estimulación Cardíaca Artificial/métodos , Ablación por Catéter/métodos , Venas Pulmonares/cirugía , Anciano , Antiarrítmicos/uso terapéutico , Fibrilación Atrial/diagnóstico , Terapia Combinada , Resistencia a Medicamentos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Resultado del Tratamiento
20.
G Ital Cardiol (Rome) ; 19(2): 119-131, 2018 Feb.
Artículo en Italiano | MEDLINE | ID: mdl-29531385

RESUMEN

BACKGROUND: The pacemaker (PM) and implantable cardioverter-defibrillator (ICD) registry of the Italian Association of Arrhythmology and Cardiac Pacing (AIAC) monitors the main epidemiological data in real-world practice. The survey for the 2016 activity collects information about demographics, clinical characteristics, main indications for PM/ICD therapy and device types from the Italian collaborating centers. METHODS: The registry collects prospectively national PM and ICD implantation activity on the basis of European cards. RESULTS: PM Registry: data about 23 496 PM implantations were collected (19 003 first implant and 4493 replacements). The number of collaborating centers was 204. Median age of treated patients was 81 years (75 quartile I; 86 quartile III). ECG indications included atrioventricular conduction disorders in 39.8% of first PM implants, sick sinus syndrome in 22.1%, atrial fibrillation plus bradycardia in 14.1%, other in 24.0%. Among atrioventricular conduction defects, third-degree atrioventricular block was the most common type (22.18% of first implants). Use of single-chamber PMs was reported in 26.9% of first implants, of dual-chamber PMs in 65.0%, of PMs with cardiac resynchronization therapy (CRT) in 1.5%, and of single lead atrial-synchronized ventricular stimulation (VDD/R PMs) in 6.6%. ICD Registry: data about 20 350 ICD implantations were collected (14 763 first implants and 5587 replacements). The number of collaborating centers was 430. Median age of treated patients was 72 years (63 quartile I; 78 quartile III]. Primary prevention indication was reported in 79.0% of first implants, secondary prevention in 21.0% (cardiac arrest in 7.9%). A single-chamber ICD was used in 32.2% of first implants, dual-chamber in 31.1% and biventricular in 36.7%. CONCLUSIONS: The PM and ICD Registry appears fundamental for monitoring PM and ICD utilization on a large national scale with rigorous examination of demographics and clinical indications. The PM Registry showed stable electrocardiographic and symptom indications, with an important prevalence of dual-chamber pacing. The use of CRT-PM regards a very limited number of patients. The ICD Registry documented a large use of prophylactic and biventricular ICD, reflecting a favorable adherence to trials and guidelines in clinical practice.


Asunto(s)
Arritmias Cardíacas/terapia , Terapia de Resincronización Cardíaca/estadística & datos numéricos , Desfibriladores Implantables/estadística & datos numéricos , Marcapaso Artificial/estadística & datos numéricos , Anciano , Anciano de 80 o más Años , Arritmias Cardíacas/epidemiología , Arritmias Cardíacas/fisiopatología , Electrocardiografía , Femenino , Humanos , Italia , Masculino , Persona de Mediana Edad , Prevención Primaria/estadística & datos numéricos , Sistema de Registros , Prevención Secundaria/estadística & datos numéricos , Sociedades Médicas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA