Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Banco de datos
Tipo de estudio
País/Región como asunto
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Environ Monit Assess ; 189(11): 574, 2017 Oct 19.
Artículo en Inglés | MEDLINE | ID: mdl-29046968

RESUMEN

Environmental surveillance of waterborne pathogens is vital for monitoring the spread of diseases, and electropositive filters are frequently used for sampling wastewater and wastewater-impacted surface water. Viruses adsorbed to electropositive filters require elution prior to detection or quantification. Elution is typically facilitated by a peristaltic pump, although this requires a significant startup cost and does not include biosafety or cross-contamination considerations. These factors may pose a barrier for low-resource laboratories that aim to conduct environmental surveillance of viruses. The objective of this study was to develop a biologically enclosed, manually powered, low-cost device for effectively eluting from electropositive ViroCap™ virus filters. The elution device described here utilizes a non-electric bilge pump, instead of an electric peristaltic pump or a positive pressure vessel. The elution device also fully encloses liquids and aerosols that could contain biological organisms, thereby increasing biosafety. Moreover, all elution device components that are used in the biosafety cabinet are autoclavable, reducing cross-contamination potential. This device reduces costs of materials while maintaining convenience in terms of size and weight. With this new device, there is little sample volume loss due to device inefficiency, similar virus yields were demonstrated during seeded studies with poliovirus type 1, and the time to elute filters is similar to that required with the peristaltic pump. The efforts described here resulted in a novel, low-cost, manually powered elution device that can facilitate environmental surveillance of pathogens through effective virus recovery from ViroCap filters while maintaining the potential for adaptability to other cartridge filters.


Asunto(s)
Monitoreo del Ambiente/métodos , Filtración/métodos , Aguas Residuales/virología , Microbiología del Agua , Adsorción , Humanos , Concentración de Iones de Hidrógeno , Poliovirus , Agua
2.
J Water Health ; 12(4): 747-54, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25473984

RESUMEN

Poliovirus (PV) is on the verge of global eradication. Due to asymptomatic shedding, eradication certification requires environmental and clinical surveillance. Current environmental surveillance methods involve collection and processing of 400-mL to 1-L grab samples by a two-phase separation method, where sample volume limits detection sensitivity. Filtration of larger sample volumes facilitates increased detection sensitivity. This study describes development of a pumpless in-field filtration system for poliovirus recovery from environmental waters. Recovery of PV types 1, 2, and 3 were compared for glass wool, ViroCap, and NanoCeram (PV1 only) filters. Seeded experiments were performed using 10(5) plaque forming units of PV inoculated into 10-L volumes of secondary effluent, surface water, or a 50:50 mixture of each at pH 7.0. Filter eluates were plated onto buffalo green monkey kidney cells for virus enumeration by plaque assay. Across all water types, recovery from glass wool filters for PV1, PV2, and PV3 averaged 17%, 28%, and 6%, respectively. Recovery from ViroCaps for PV1, PV2, and PV3 averaged 44%, 70%, and 81%, respectively. 10-L samples of moderate turbidity water were processed through ViroCap filters in less than 30 minutes using a pumpless, bag-mediated filtration system. Bag-mediated filtration offers a simple, compact, and efficient method for enhanced environmental PV surveillance.


Asunto(s)
Monitoreo del Ambiente/instrumentación , Poliovirus/aislamiento & purificación , Aguas del Alcantarillado/virología , Ultrafiltración/instrumentación , Aguas Residuales/virología , Microbiología del Agua , Animales , Células Cultivadas , Chlorocebus aethiops , Ensayo de Placa Viral
3.
Food Environ Virol ; 10(1): 72-82, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-28674934

RESUMEN

Environmental surveillance of poliovirus (PV) plays an important role in the global program for eradication of wild PV. The bag-mediated filtration system (BMFS) was first developed in 2014 and enhances PV surveillance when compared to the two-phase grab method currently recommended by the World Health Organization (WHO). In this study, the BMFS design was improved and tested for its usability in wastewater and wastewater-impacted surface waters in Nairobi, Kenya. Modifications made to the BMFS included the size, color, and shape of the collection bags, the filter housing used, and the device used to elute the samples from the filters. The modified BMFS concentrated 3-10 L down to 10 mL, which resulted in an effective volume assayed (900-3000 mL) that was 6-20 times greater than the effective volume assayed for samples processed by the WHO algorithm (150 mL). The system developed allows for sampling and in-field virus concentration, followed by transportation of the filter for further analysis with simpler logistics than the current methods. This may ultimately reduce the likelihood of false-negative samples by increasing the effective volume assayed compared to samples processed by the WHO algorithm, making the BMFS a valuable sampling system for wastewater and wastewater-impacted surface waters.


Asunto(s)
Monitoreo del Ambiente/métodos , Filtración/métodos , Poliomielitis/virología , Poliovirus/crecimiento & desarrollo , Aguas Residuales/virología , Contaminación del Agua , Humanos , Kenia , Aguas del Alcantarillado/virología , Agua , Microbiología del Agua
4.
Food Environ Virol ; 9(4): 383-394, 2017 12.
Artículo en Inglés | MEDLINE | ID: mdl-28616833

RESUMEN

Environmental surveillance of poliovirus (PV) and other non-enveloped viruses can help identify silent circulation and is necessary to certify eradication. The bag-mediated filtration system is an efficient method to filter large volumes of environmental waters at field sites for monitoring the presence of viruses. As filters may require long transit times to off-site laboratories for processing, viral inactivation or overgrowth of bacteria and fungi can interfere with virus detection and quantification (Miki and Jacquet in Aquatic Microb Ecol 51(2):195-208, 2008). To evaluate virus survival over time on ViroCap™ filters, the filters were seeded with PV type 1 (PV1) and/or MS2 and then dosed with preservatives or antibiotics prior to storage and elution. These filters were stored at various temperatures and time periods, and then eluted for PV1 and MS2 recovery quantification. Filters dosed with the preservative combination of 2% sodium benzoate and 0.2% calcium propionate had increased virus survival over time when stored at 25 °C, compared to samples stored at 25 °C with no preservatives. While elution within 24 h of filtration is recommended, if storage or shipping is required then this preservative mixture can help preserve sample integrity. Addition of an antibiotic cocktail containing cephapirin, gentamicin, and Proclin™ 300 increased recovery after storage at 4 and 25 °C, when compared to storage with no antibiotics. The antibiotic cocktail can aid sample preservation if access to appropriate antibiotics storage is available and sample cold chain is unreliable. This study demonstrated that the use of preservatives or antibiotics is a simple, cost-effective method to improve virus detection from ViroCap cartridge filters over time.


Asunto(s)
Antibacterianos/farmacología , Filtración/métodos , Poliovirus/efectos de los fármacos , Poliovirus/crecimiento & desarrollo , Conservadores Farmacéuticos/farmacología , Monitoreo del Ambiente , Filtración/instrumentación , Agua Dulce/virología , Poliovirus/aislamiento & purificación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA