Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Magn Reson Med ; 90(5): 2144-2157, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37345727

RESUMEN

PURPOSE: This paper presents a hierarchical modeling approach for estimating cardiomyocyte major and minor diameters and intracellular volume fraction (ICV) using diffusion-weighted MRI (DWI) data in ex vivo mouse hearts. METHODS: DWI data were acquired on two healthy controls and two hearts 3 weeks post transverse aortic constriction (TAC) using a bespoke diffusion scheme with multiple diffusion times ( Δ $$ \Delta $$ ), q-shells and diffusion encoding directions. Firstly, a bi-exponential tensor model was fitted separately at each diffusion time to disentangle the dependence on diffusion times from diffusion weightings, that is, b-values. The slow-diffusing component was attributed to the restricted diffusion inside cardiomyocytes. ICV was then extrapolated at Δ = 0 $$ \Delta =0 $$ using linear regression. Secondly, given the secondary and the tertiary diffusion eigenvalue measurements for the slow-diffusing component obtained at different diffusion times, major and minor diameters were estimated assuming a cylinder model with an elliptical cross-section (ECS). High-resolution three-dimensional synchrotron X-ray imaging (SRI) data from the same specimen was utilized to evaluate the biophysical parameters. RESULTS: Estimated parameters using DWI data were (control 1/control 2 vs. TAC 1/TAC 2): major diameter-17.4 µ $$ \mu $$ m/18.0 µ $$ \mu $$ m versus 19.2 µ $$ \mu $$ m/19.0 µ $$ \mu $$ m; minor diameter-10.2 µ $$ \mu $$ m/9.4 µ $$ \mu $$ m versus 12.8 µ $$ \mu $$ m/13.4 µ $$ \mu $$ m; and ICV-62%/62% versus 68%/47%. These findings were consistent with SRI measurements. CONCLUSION: The proposed method allowed for accurate estimation of biophysical parameters suggesting cardiomyocyte diameters as sensitive biomarkers of hypertrophy in the heart.


Asunto(s)
Estenosis de la Válvula Aórtica , Miocitos Cardíacos , Ratones , Animales , Imagen de Difusión por Resonancia Magnética/métodos , Cardiomegalia/diagnóstico por imagen , Imagenología Tridimensional
2.
J Arthroplasty ; 37(1): 75-82, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34649747

RESUMEN

BACKGROUND: Ceramic-on-ceramic bearings permit the use of large femoral head size while maintaining a favorable effect on wear rates. However, because of increased device rigidity, periprosthetic bone quality could be negatively affected due to stress shielding. The purpose of this study is to assess pelvic periprosthetic bone remodeling around a monoblock ceramic-on-ceramic acetabular component compared to that around a conventional modular metal-on-polyethylene device. METHODS: Participants were randomized to receive hip replacement using either a porous-coated, modular metal-on-polyethylene acetabular component (n = 46) or a hydroxyapatite and titanium-coated monoblock shell with an integrated ceramic-on-ceramic bearing (n = 40). Radiographic assessments were completed preoperatively and postoperatively, and measurements of bone mineral density (BMD) using dual-energy X-ray absorptiometry with region free analysis were performed postoperatively and over 2-years of follow-up. RESULTS: There was no significant difference in BMD between the 2 groups at baseline or over the following 2 years. At follow-up, complete shell-to-bone contact without a radiolucent line was observed in 26 (67%) of the modular devices and in 37 (93%) of monoblock (P < .001). The modular device was an independent predictor of radiolucent lines (odds ratio 19.1, P = .007). No cases underwent revision surgery for acetabular loosening. CONCLUSION: Both the porous-coated modular and hydroxyapatite-coated monoblock acetabular components showed successful clinical results at short-term follow-up with no difference in pixel-level BMD. Using a large head monoblock device does not appear to be associated with an adverse effect on the local bone environment when compared to a modular device. NCT: NCT01558752.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Acetábulo/diagnóstico por imagen , Acetábulo/cirugía , Artroplastia de Reemplazo de Cadera/efectos adversos , Cerámica , Estudios de Seguimiento , Humanos , Diseño de Prótesis , Falla de Prótesis , Reoperación
3.
J Clin Densitom ; 20(4): 480-485, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28652104

RESUMEN

The gold standard tool for measuring periprosthetic bone mineral density (BMD) is dual-energy X-ray absorptiometry (DXA). However, resolution of the method is limited due to the aggregation of pixel data into large regions of interest for clinical and statistical analysis. We have previously validated a region-free analysis method (DXA-RFA) for quantitating BMD change at the pixel level around femoral prostheses. Here, we applied the DXA-RFA method to the pelvis, and quantitated its precision in this setting using repeated DXA scans taken on the same day after repositioning in 29 patients after total hip arthroplasty. Scans were semiautomatically segmented using edge detection, intensity thresholding, and morphologic operations, and elastically registered to a common template generated through generalized Procrustes analysis. Pixel-wise BMD precision between repeated scans was expressed as a coefficient of variation %. Longitudinal BMD change was assessed in an independent group of 24 patients followed up for 260 wk. DXA-RFA spatial resolution of 0.31 mm2 provided approximately 12,500 data points per scan. The median data-point precision was 17.8% (interquartile range 14.3%-22.7%). The anatomic distribution of the precision errors showed poorer precision at the bone borders and superior precision to the obturator foramen. Evaluation of longitudinal BMD showed focal BMD change at 260 wk of -26.8% adjacent to the prosthesis-bone interface (1% of bone map area). In contrast, BMD change of +39.0% was observed at the outer aspect of the ischium (3% of bone map area). Pelvic DXA-RFA is less precise than conventional DXA analysis. However, it is sensitive for detecting local BMD change events in groups of patients, and provides a novel tool for quantitating local bone mass after joint replacement. Using this method, we were able to resolve BMD change over small areas adjacent to the implant-bone interface and in the ischial region over 260 wk after total hip arthroplasty.


Asunto(s)
Absorciometría de Fotón , Densidad Ósea , Remodelación Ósea , Fémur/diagnóstico por imagen , Fémur/fisiología , Procesamiento de Imagen Asistido por Computador , Adulto , Artroplastia de Reemplazo de Cadera , Femenino , Estudios de Seguimiento , Prótesis de Cadera , Humanos , Isquion/diagnóstico por imagen , Isquion/fisiología , Masculino , Persona de Mediana Edad , Osteoartritis/cirugía , Factores de Tiempo
4.
J Bone Miner Res ; 37(9): 1679-1688, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35748609

RESUMEN

The risk of osteoporotic fracture is inversely related to bone mineral density (BMD), but how spatial BMD pattern influences fracture risk remains incompletely understood. This study used a pixel-level spatiotemporal atlas of proximal femoral BMD in 13,338 white European women (age 20-97 years) to quantitate age-related texture variation in BMD maps and generate a "reference" map of bone aging. We introduce a new index, called Densitometric Bone Age (DBA), as the age at which an individual site-specific BMD map (the proximal femur is studied here) best matches the median aging trajectory at that site in terms of the root mean squared error (RMSE). The ability of DBA to predict incident hip fracture and hip fracture pattern over 5 years following baseline BMD was compared against conventional region-based BMD analysis in a subset of 11,899 women (age 45-97 years), for which follow-up fracture records exist. There were 208 subsequent incident hip fractures in the study populations (138 femoral necks [FNs], 52 trochanteric [TR], 18 sites unspecified). DBA had modestly better performance compared to the conventional FN-BMD, TR-BMD, and total hip (TOT)-BMD in identifying hip fractures measured as the area under the curve (AUC) using receiver operating characteristics (ROC) curve analysis by 2% (95% confidence interval [CI], -0.5% to 3.5%), 3% (95% CI, 1.0% to 4.0%), and 1% (95% CI, 0.4% to 1.6%), respectively. Compared to FN-BMD T-score, DBA improved the ROC-AUC for predicting TR fractures by ~5% (95% CI, 1.1% to 9.8%) with similar performance in identifying FN fractures. Compared to TR-BMD T-score, DBA improved the ROC-AUC for the prediction of FN fractures by ~3% (95% CI, 1.1% to 4.9%), with similar performance in identifying TR fractures. Our findings suggest that DBA may provide a spatially sensitive measure of proximal femoral fragility that is not captured by FN-BMD or TR-BMD alone. © 2022 The Authors. Journal of Bone and Mineral Research published by Wiley Periodicals LLC on behalf of American Society for Bone and Mineral Research (ASBMR).


Asunto(s)
Fracturas de Cadera , Fracturas Osteoporóticas , Absorciometría de Fotón , Adulto , Anciano , Anciano de 80 o más Años , Densidad Ósea , Femenino , Cuello Femoral , Fracturas de Cadera/diagnóstico por imagen , Fracturas de Cadera/epidemiología , Humanos , Persona de Mediana Edad , Fracturas Osteoporóticas/diagnóstico por imagen , Fracturas Osteoporóticas/epidemiología , Adulto Joven
5.
J Bone Joint Surg Am ; 103(1): 74-83, 2021 Jan 06.
Artículo en Inglés | MEDLINE | ID: mdl-33079901

RESUMEN

BACKGROUND: In this randomized controlled trial (RCT), we compared bone remodeling and bone turnover between 2 total hip arthroplasty implants-the short, proximally porous-coated Tri-Lock Bone-Preservation Stem and a conventional, fully-coated Corail prosthesis-over a 2-year postoperative period. METHODS: Forty-six participants received the Tri-Lock prosthesis and 40 received the Corail prosthesis. At baseline, the 2 groups had similar demographics, proximal femoral bone mineral density (BMD), bone turnover markers, radiographic canal flare index, and patient-reported outcome measure (PROM) scores. Outcomes were measured at weeks 26, 52, and 104. RESULTS: Loss of periprosthetic bone, measured by high-sensitivity dual x-ray absorptiometry region-free analysis (DXA-RFA), was identified at the calcar and proximal-lateral aspect of the femur in both prosthesis groups (p < 0.05). However, the conventional prosthesis was associated with a smaller reduction in BMD compared with the bone-preservation prosthesis (p < 0.001). This effect was most prominent in the region of the femoral calcar and greater trochanter. A small gain in BMD was also identified in some areas, and this gain was greater with the conventional than the bone-preservation prosthesis (p < 0.001). The 2 groups had similar changes in bone turnover markers and improvement in PROM scores over the study period (p > 0.05). The adverse-event rate was also similar between the groups (p > 0.05). CONCLUSIONS: This RCT shows that prostheses intended to preserve proximal femoral bone do not necessarily perform better in this regard than conventional cementless designs. DXA-RFA is a sensitive tool for detecting spatially complex patterns of periprosthetic bone remodeling. LEVEL OF EVIDENCE: Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Remodelación Ósea , Fémur/diagnóstico por imagen , Prótesis de Cadera , Osteoartritis de la Cadera/diagnóstico por imagen , Absorciometría de Fotón , Anciano , Artroplastia de Reemplazo de Cadera/efectos adversos , Densidad Ósea , Resorción Ósea/diagnóstico por imagen , Femenino , Fémur/cirugía , Prótesis de Cadera/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Osteoartritis de la Cadera/cirugía , Medición de Resultados Informados por el Paciente , Diseño de Prótesis/efectos adversos
6.
IEEE Trans Med Imaging ; 40(12): 3775-3786, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34270420

RESUMEN

Biophysical models are a promising means for interpreting diffusion weighted magnetic resonance imaging (DW-MRI) data, as they can provide estimates of physiologically relevant parameters of microstructure including cell size, volume fraction, or dispersion. However, their application in cardiac microstructure mapping (CMM) has been limited. This study proposes seven new two-compartment models with combination of restricted cylinder models and a diffusion tensor to represent intra- and extracellular spaces, respectively. Three extended versions of the cylinder model are studied here: cylinder with elliptical cross section (ECS), cylinder with Gamma distributed radii (GDR), and cylinder with Bingham distributed axes (BDA). The proposed models were applied to data in two fixed mouse hearts, acquired with multiple diffusion times, q-shells and diffusion encoding directions. The cylinderGDR-pancake model provided the best performance in terms of root mean squared error (RMSE) reducing it by 25% compared to diffusion tensor imaging (DTI). The cylinderBDA-pancake model represented anatomical findings closest as it also allows for modelling dispersion. High-resolution 3D synchrotron X-ray imaging (SRI) data from the same specimen was utilized to evaluate the biophysical models. A novel tensor-based registration method is proposed to align SRI structure tensors to the MR diffusion tensors. The consistency between SRI and DW-MRI parameters demonstrates the potential of compartment models in assessing physiologically relevant parameters.


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Imagen de Difusión Tensora , Animales , Difusión , Ratones , Miocardio
7.
IEEE Trans Med Imaging ; 39(5): 1359-1368, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-31647421

RESUMEN

Osteoporosis is an age-associated disease characterised by low bone mineral density (BMD) and micro-architectural deterioration leading to enhanced fracture risk. Conventional dual-energy X-ray absorptiometry (DXA) analysis has facilitated our understanding of BMD reduction in specific regions of interest (ROIs) within the femur, but cannot resolve spatial BMD patterns nor reflect age-related changes in bone microarchitecture due to its inherent averaging of pixel BMD values into large ROIs. To address these limitations and develop a comprehensive model of involutional bone loss, this paper presents a fully automatic pipeline to build a spatio-temporal atlas of ageing bone in the proximal femur. A new technique, termed DXA region free analysis (DXA RFA), is proposed to eliminate morphological variation between DXA scans by warping each image into a reference template. To construct the atlas, we use unprocessed DXA data from Caucasian women aged 20-97 years participating in three cohort studies in Western Europe ( ,000). A novel calibration procedure, termed quantile matching regression, is proposed to integrate data from different DXA manufacturers. Pixel-wise BMD evolution with ageing was modelled using smooth quantile curves. This technique enables characterisation of spatially-complex BMD change patterns with ageing, visualised using heat-maps. Furthermore, quantile curves plotted at different pixel coordinates showed consistently different rates of bone loss at different regions within the femoral neck. Given the close relationship between spatio-temporal bone loss and osteoporotic fracture, improved understanding of the bone ageing process could lead to enhanced prognostic, preventive and therapeutic strategies for the disease.


Asunto(s)
Densidad Ósea , Osteoporosis , Absorciometría de Fotón , Envejecimiento , Femenino , Fémur/diagnóstico por imagen , Humanos , Osteoporosis/diagnóstico por imagen
8.
J Orthop Res ; 35(10): 2203-2210, 2017 10.
Artículo en Inglés | MEDLINE | ID: mdl-28169450

RESUMEN

Dual energy X-ray absorptiometry (DXA) is the reference standard method used to study bone mineral density (BMD) after total hip arthroplasty (THA). However, the subtle, spatially complex changes in bone mass due to strain-adaptive bone remodeling relevant to different prosthesis designs are not readily resolved using conventional DXA analysis. DXA region free analysis (DXA RFA) is a novel computational image analysis technique that provides a high-resolution quantitation of periprosthetic BMD. Here, we applied the technique to quantitate the magnitude and areal size of periprosthetic BMD changes using scans acquired during two previous randomized clinical trials (2004 to 2009); one comparing three cemented prosthesis design geometries, and the other comparing a hip resurfacing versus a conventional cementless prosthesis. DXA RFA resolved subtle differences in magnitude and area of bone remodeling between prosthesis designs not previously identified in conventional DXA analyses. A mean bone loss of 10.3%, 12.1%, and 11.1% occurred for the three cemented prostheses within a bone area fraction of 14.8%, 14.4%, and 6.2%, mostly within the lesser trochanter (p < 0.001). For the cementless prosthesis, a diffuse pattern of bone loss (-14.3%) was observed at the shaft of femur in a small area fraction of 0.6% versus no significant bone loss for the hip resurfacing prosthesis (p < 0.001). BMD increases were observed consistently at the greater trochanter for all prostheses except the hip-resurfacing prosthesis, where BMD increase was widespread across the metaphysis (p < 0.001). DXA RFA provides high-resolution insights into the effect of prosthesis design on the local strain environment in bone. © 2017 The Authors Journal of Orthopaedic Research published by Wiley Periodicals, Inc. on behalf of Orthopaedic Research Society. J Orthop Res 35:2203-2210, 2017.


Asunto(s)
Remodelación Ósea , Densitometría/métodos , Fémur/fisiología , Prótesis de Cadera , Diseño de Prótesis , Adulto , Anciano , Artroplastia de Reemplazo de Cadera/instrumentación , Densidad Ósea , Femenino , Humanos , Masculino , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA