Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros

Banco de datos
Tipo de estudio
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Am Chem Soc ; 144(14): 6383-6389, 2022 Apr 13.
Artículo en Inglés | MEDLINE | ID: mdl-35353513

RESUMEN

Lanthanide/actinide separation is a worldwide challenge for atomic energy and nuclear waste treatment. Separation of americium (Am), a critical actinide element in the nuclear fuel cycle, from lanthanides (Ln) is highly desirable for minimizing the long-term radiotoxicity of nuclear waste, yet it is extremely challenging given the chemical similarity between trivalent Am(III) and Ln(III). Selective oxidation of Am(III) to a higher oxidation state (OS) could facilitate this separation, but so far, it is far from satisfactory for practical application as a result of the unstable nature of Am in a high OS. Herein, we find a novel strategy to generate stable pentavalent Am (Am(V)) through coordination of Am(III) with a diglycolamide ligand and oxidation with Bi(V) species in the presence of an organic solvent. This strategy leads to efficient stabilization of Am(V) and an extraordinarily high separation factor (>104) of Am from Ln through one single contact in solvent extraction, thereby opening a new avenue to study the high-OS chemistry of Am and fulfill the crucial task of Ln/Am separation in the nuclear fuel cycle. The synergistic coordination and oxidation process is found to occur in the organic solvent, and the mechanism has been well elucidated by quantum-theoretical modeling.

2.
Inorg Chem ; 58(1): 603-609, 2019 Jan 07.
Artículo en Inglés | MEDLINE | ID: mdl-30565939

RESUMEN

Here, we propose the use of carboxyl-functionalized ionic liquid, [Hbet][Tf2N], to separate the fission products from spent nuclear fuels. This innovative method allows the selective dissolution of neutron poisons, lanthanides oxide, as well as some fission products with high yield, leaving most of the UO2 matrix and minor actinides behind in the spent nuclear fuel and accomplishing the actinides recovery as a group. Water-saturated [Hbet][Tf2N] can dissolve lanthanides oxide from simulated spent nuclear fuel with a dissolution ratio of 100% at 40 °C. However, the dissolution of uranium is almost negligible (<1%) under the same conditions. This big difference in dissolution provides a novel separation approach to spent nuclear fuel recycling and may open new perspectives for spent nuclear fuel reprocessing. The recovery of Nd and U from metal-loaded ionic liquids and the recyclability of the ionic liquid [Hbet][Tf2N] have also been investigated. Furthermore, a U/ x value related to the lattice energy U of metal compound M xO y is used to elaborate the solubility. This work represents the first case for efficient fission products removal by selective dissolution, avoiding the complete dissolution of spent nuclear fuel, the producing of the large high-level radioactive waste, and reducing environmental hazards.

3.
Appl Radiat Isot ; 104: 147-54, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26163292

RESUMEN

For measuring a sample stored for a long period of time using liquid scintillation counting (LSC), it is necessary to study the long-term stability of the sample. The effect of sample stability on the determination of radioactivity for (241)Am, (90)Sr/(90)Y, (137)Cs, (147)Pm, (237)Np/(233)Pa, and (3)H by LSC has been investigated. The variation of quench level over time can be an indication of sample stability. If the variation in a sample is little, the effect of sample stability on the determination of the above radionuclides can be neglected. Otherwise, the sample stability will have impact not only on the counting efficiency (especially for low energy ß emitters), but also on the results of α/ß discrimination. For studying the stability of a sample, special attention should be paid to the radionuclides with chemical form apt to be adsorbed, because the quench level of a sample cannot be reflected by the quench index SQP(E) alone when significant physical quench exists. Shaking a sample stored for a long period of time and checking the LSC spectra can give the information on physical quench in the sample. In the range of this study, OptiPhase Hisafe 3 has much better quench resistance than Ultima Gold AB.

4.
Appl Radiat Isot ; 93: 114-9, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24582116

RESUMEN

In the application of liquid scintillation counting (LSC), the α/ß discrimination is carried out with the function of pulse shape analysis (PSA), which requires the setting of the optimum PSA level. The optimum PSA are usually determined by the generation of cross-over plots, whereby a pair of vials, one containing a pure α emitter and the other a pure ß emitter, is counted. However, in some cases such as the determination of (237)Np/(233)Pa, a pure α emitter or a pure ß emitter is not available. Therefore, we have developed a new approach to set the optimum PSA by measuring the sample itself of mixed α/ß emitters. The count rate of the sample in the α-multi-channel analyzer changes monotonically with the increase of the PSA, and there is always an inflection point which is related to the optimum PSA. By fitting the data near the inflection point with the function y=ax(3)+bx(2)+cx+d, we can obtain the optimum PSA as -b/(3a), which can be used to determine the radioactivity of (237)Np/(233)Pa. The results obtained with this new approach were in good agreement with those obtained by HPGe γ spectrometry that was calibrated with an LSC sample of (237)Np/(233)Pa under a radioactive secular equilibrium. The new approach is promising to be used in simultaneous determination of gross α and ß emitters, especially in the absence of a pure α or ß emitter.

5.
J Hazard Mater ; 278: 566-71, 2014 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-25016455

RESUMEN

High level liquid waste (HLLW) produced from the reprocessing of the spent nuclear fuel still contains moderate amounts of uranium, transuranium (TRU) actinides, (90)Sr, (137)Cs, etc., and thus constitutes a permanent hazard to the environment. The partitioning and transmutation (P&T) strategy has increasingly attracted interest for the safe treatment and disposal of HLLW, in which the partitioning of HLLW is one of the critical technical issues. An improved total partitioning process, including a TRPO (tri-alkylphosphine oxide) process for the removal of actinides, a CESE (crown ether strontium extraction) process for the removal of Sr, and a CECE (calixcrown ether cesium extraction) process for the removal of Cs, has been developed to treat Chinese HLLW. A 160-hour hot test of the improved total partitioning process was carried out using 72-stage 10-mm-dia annular centrifugal contactors (ACCs) and genuine HLLW. The hot test results showed that the average DFs of total α activity, Sr and Cs were 3.57 × 10(3), 2.25 × 10(4) and 1.68 × 10(4) after the hot test reached equilibrium, respectively. During the hot test, 72-stage 10-mm-dia ACCs worked stable, continuously with no stage failing or interruption of the operation.


Asunto(s)
Radioisótopos de Cesio/química , Éteres Corona/química , Compuestos Organofosforados/química , Radioisótopos de Estroncio/química , 1-Octanol/química , Calor , Residuos Radiactivos
6.
Appl Radiat Isot ; 70(8): 1536-40, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-22732387

RESUMEN

The long-term stability of a cocktail is very important for liquid scintillation counting. The expiry date of a cocktail labeled on the container is usually one to three years later than the manufacture date, which is fairly short for the convenience of purchase, storage and use. Three batches of a diisopropylnaphthalene-based aqueous-miscible cocktail, Ultima Gold AB, with a span of 18 years of storage, have been compared on their basic performances, i.e. background count rate, counting efficiency, quench resistance, and α/ß discrimination. We found that the 18-year storage has less impact on the basic performances than batch-to-batch variability in cocktail compositions, which means Ultima Gold AB has very good long-term stability. Therefore, in practice Ultima Gold AB can be used even beyond its expiry date, if it is properly stored for less than 18 years. This result will bring much convenience to plan the purchase, storage and use of the cocktail. In addition, the influence of statistical fluctuations on the quench parameter SQP(E) has been studied.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA