Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Eur Radiol ; 34(8): 5190-5200, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38183450

RESUMEN

OBJECTIVES: Partial thrombosis of the false lumen (FL) in patients with chronic aortic dissection (AD) of the descending aorta has been associated with poor outcomes. Meanwhile, the fluid dynamic and biomechanical characteristics associated with partial thrombosis remain to be elucidated. This retrospective, single-center study tested the association between FL fluid dynamics and biomechanics and the presence and extent of FL thrombus. METHODS: Patients with chronic non-thrombosed or partially thrombosed FLs in the descending aorta after an aortic dissection underwent computed tomography angiography, cardiovascular magnetic resonance (CMR) angiography, and a 4D flow CMR study. A comprehensive quantitative analysis was performed to test the association between FL thrombus presence and extent (percentage of FL with thrombus) and FL anatomy (diameter, entry tear location and size), fluid dynamics (inflow, rotational flow, wall shear stress, kinetic energy, and flow acceleration and stasis), and biomechanics (pulse wave velocity). RESULTS: Sixty-eight patients were included. In multivariate logistic regression FL kinetic energy (p = 0.038) discriminated the 33 patients with partial FL thrombosis from the 35 patients with no thrombosis. Similarly, in separated multivariate linear correlations kinetic energy (p = 0.006) and FL inflow (p = 0.002) were independently related to the extent of the thrombus. FL vortexes, flow acceleration and stasis, wall shear stress, and pulse wave velocity showed limited associations with thrombus presence and extent. CONCLUSION: In patients with chronic descending aorta dissection, false lumen kinetic energy is related to the presence and extent of false lumen thrombus. CLINICAL RELEVANCE STATEMENT: In patients with chronic aortic dissection of the descending aorta, false lumen hemodynamic parameters are closely linked with the presence and extent of false lumen thrombosis, and these non-invasive measures might be important in patient management. KEY POINTS: • Partial false lumen thrombosis has been associated with aortic growth in patients with chronic descending aortic dissection; therefore, the identification of prothrombotic flow conditions is desirable. • The presence of partial false lumen thrombosis as well as its extent was related with false lumen kinetic energy. • The assessment of false lumen hemodynamics may be important in the management of patients with chronic aortic dissection of the descending aorta.


Asunto(s)
Aorta Torácica , Disección Aórtica , Hemodinámica , Trombosis , Humanos , Masculino , Femenino , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/fisiopatología , Disección Aórtica/complicaciones , Persona de Mediana Edad , Estudios Retrospectivos , Trombosis/diagnóstico por imagen , Trombosis/fisiopatología , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/fisiopatología , Angiografía por Tomografía Computarizada/métodos , Enfermedad Crónica , Anciano , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/fisiopatología , Aneurisma de la Aorta Torácica/complicaciones , Angiografía por Resonancia Magnética/métodos
2.
J Cardiovasc Magn Reson ; : 101088, 2024 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-39214465

RESUMEN

OBJECTIVES: Patients with syndromic heritable thoracic aortic diseases (sHTAD) who underwent prophylactic aortic root replacement are at high risk of distal aortic events, but the underlying mechanisms are poorly understood. This prospective, longitudinal study aims to assess the impact of valve-sparing aortic root replacement (VSARR) on aortic fluid dynamics and biomechanics in these patients, and to examine whether they present altered haemodynamics or biomechanics prior to surgery compared to sHTAD patients with no indication for surgery (sHTAD-NSx) and healthy volunteers (HV). METHODS: Sixteen patients with Marfan or Loeys-Dietz syndrome underwent two 4D flow CMR studies before (sHTAD-preSx) and after VSARR (sHTAD-postSx). Two age, sex and BSA matched cohorts of 40 HV and 16 sHTAD-NSx patients with available 4D flow CMR, were selected for comparison. In-plane rotational flow (IRF), systolic flow reversal ratio (SFRR), wall shear stress (WSS), pulse wave velocity (PWV) and aortic strain were analysed in the ascending (AscAo) and descending aorta (DescAo). RESULTS: All patients with sHTAD presented altered haemodynamics and increased aortic stiffness (p<0.05) compared to HV, both in the AscAo (median PWV 7.4 in sHTAD-NSx; 6.8 in sHTAD-preSx; 4.9m/s in HV) and DescAo (median PWV 9.1 in sHTAD-NSx; 8.1 in sHTAD-preSx; 6.3m/s in HV). Patients awaiting VSARR had markedly reduced in-plane (median IRF -2.2 vs 10.4 cm2/s in HV, p=0.001), but increased through-plane flow rotation (median SFRR 7.8 vs 3.8% in HV, p=0.002), and decreased WSS (0.36 vs 0.47N/m2 in HV, p=0.004) in the proximal DescAo. After VSARR, proximal DescAo in-plane rotational flow (p=0.010) and circumferential WSS increased (p=0.011), no longer differing from HV, but through-plane rotational flow, axial WSS and stiffness remained altered. Patients in which aortic tortuosity was reduced after surgery showed greater post-surgical increase in IRF compared to those in which tortuosity increased (median IRF increase 18.1 vs 3.3cm²/s, p=0.047). Most AscAo flow alterations were restored to physiological values after VSARR. CONCLUSIONS: In patients with sHTAD, VSARR partially restores downstream fluid dynamics to physiological levels. However, some flow disturbances and increased stiffness persist in the proximal DescAo. Further longitudinal studies are needed to evaluate whether persistent alterations contribute to post-surgical risk.

3.
J Cardiovasc Magn Reson ; 26(1): 100992, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38211655

RESUMEN

BACKGROUND: The measurement of aortic dimensions and their evolution are key in the management of patients with aortic diseases. Manual assessment, the current guideline-recommended method and clinical standard, is subjective, poorly reproducible, and time-consuming, limiting the capacity to track aortic growth in everyday practice. Aortic geometry mapping (AGM) via image registration of serial computed tomography angiograms outperforms manual assessment, providing accurate and reproducible 3D maps of aortic diameter and growth rate. This observational study aimed to evaluate the accuracy and reproducibility of AGM on non-gated contrast-enhanced (CE-) and cardiac- and respiratory-gated (GN-) magnetic resonance angiographies (MRA). METHODS: Patients with thoracic aortic disease followed with serial CE-MRA (n = 30) or GN-MRA (n = 15) acquired at least 1 year apart were retrospectively and consecutively identified. Two independent observers measured aortic diameters and growth rates (GR) manually at several thoracic aorta reference levels and with AGM. Agreement between manual and AGM measurements and their inter-observer reproducibility were compared. Reproducibility for aortic diameter and GR maps assessed with AGM was obtained. RESULTS: Mean follow-up was 3.8 ± 2.3 years for CE- and 2.7 ± 1.6 years for GN-MRA. AGM was feasible in the 93% of CE-MRA pairs and in the 100% of GN-MRA pairs. Manual and AGM diameters showed excellent agreement and inter-observer reproducibility (ICC>0.9) at all anatomical levels. Agreement between manual and AGM GR was more limited, both in the aortic root by GN-MRA (ICC=0.47) and in the thoracic aorta, where higher accuracy was obtained with GN- than with CE-MRA (ICC=0.55 vs 0.43). The inter-observer reproducibility of GR by AGM was superior compared to manual assessment, both with CE- (thoracic: ICC= 0.91 vs 0.51) and GN-MRA (root: ICC=0.84 vs 0.52; thoracic: ICC=0.93 vs 0.60). AGM-based 3D aortic size and growth maps were highly reproducible (median ICC >0.9 for diameters and >0.80 for GR). CONCLUSION: Mapping aortic diameter and growth on MRA via 3D image registration is feasible, accurate and outperforms the current manual clinical standard. This technique could broaden the possibilities of clinical and research evaluation of patients with aortic thoracic diseases.


Asunto(s)
Aorta Torácica , Enfermedades de la Aorta , Medios de Contraste , Imagenología Tridimensional , Angiografía por Resonancia Magnética , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Humanos , Reproducibilidad de los Resultados , Masculino , Femenino , Estudios Retrospectivos , Persona de Mediana Edad , Aorta Torácica/diagnóstico por imagen , Anciano , Medios de Contraste/administración & dosificación , Enfermedades de la Aorta/diagnóstico por imagen , Técnicas de Imagen Sincronizada Respiratorias , Adulto , Factores de Tiempo , Interpretación de Imagen Asistida por Computador , Técnicas de Imagen Sincronizada Cardíacas
4.
Eur Radiol ; 32(3): 1997-2009, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34655311

RESUMEN

OBJECTIVES: Manual assessment of aortic diameters on double-oblique reformatted computed tomography angiograms (CTA) is considered the current standard, although the reproducibility for growth rates has not been reported. Deformable registration of CTA has been proposed to provide 3D aortic diameters and growth maps, but validation is lacking. This study aimed to quantify accuracy and inter-observer reproducibility of registration-based and manual assessment of aortic diameters and growth rates. METHODS: Forty patients with ≥ 2 CTA acquired at least 6 months apart were included. Aortic diameters and growth rate were obtained in the aortic root and the entire thoracic aorta using deformable image registration by two independent observers, and compared with the current standard at typical anatomical landmarks. RESULTS: Compared with manual assessment, the registration-based technique presented low bias (0.46 mm), excellent agreement (ICC = 0.99), and similar inter-observer reproducibility (ICC = 0.99 for both) for aortic diameters; and low bias (0.10 mm/year), good agreement (ICC = 0.82), and much higher inter-observer reproducibility for growth rates (root: ICC = 0.96 vs 0.68; thoracic aorta: ICC = 0.96 vs 0.80). Registration-based growth rate reproducibility over a 6-month-long follow-up was similar to that obtained by manual assessment after 2.7 years (LoA = [- 0.01, 0.33] vs [- 0.13, 0.21] mm/year, respectively). Mapping of diameter and growth rate was highly reproducible (ICC > 0.9) in the whole thoracic aorta. CONCLUSIONS: Registration-based assessment of aortic dilation on CTA is accurate and substantially more reproducible than the current standard, even at follow-up as short as 6 months, and provides robust 3D mapping of aortic diameters and growth rates beyond the pre-established anatomic landmarks. KEY POINTS: • Registration-based semi-automatic assessment of progressive aortic dilation on CTA is accurate and substantially more reproducible than the current standard. • The registration-based technique allows robust growth rate assessment at follow-up as short as 6 months, with a similar reproducibility to that obtained by manual assessment at around 3 years. • The use of image registration provides robust 3D mapping of aortic diameters and growth rates beyond the pre-established anatomic landmarks.


Asunto(s)
Angiografía por Tomografía Computarizada , Tomografía Computarizada por Rayos X , Aorta , Aorta Torácica/diagnóstico por imagen , Humanos , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados
5.
J Cardiovasc Magn Reson ; 24(1): 20, 2022 03 28.
Artículo en Inglés | MEDLINE | ID: mdl-35346239

RESUMEN

BACKGROUND: Patency of the false lumen in chronic aortic dissection (AD) is associated with aortic dilation and long-term aortic events. However, predictors of adverse outcomes in this population are limited. The aim of this study was to evaluate the relationship between aortic growth rate and false lumen flow dynamics and biomechanics in patients with chronic, patent AD. METHODS: Patients with a chronic AD with patent false lumen in the descending aorta and no genetic connective tissue disorder underwent an imaging follow-up including a contrast-enhanced 4D flow cardiovascular magnetic resonance (CMR) protocol and two consecutive computed tomography angiograms (CTA) acquired at least 1 year apart. A comprehensive analysis of anatomical features (including thrombus quantification), and false lumen flow dynamics and biomechanics (pulse wave velocity) was performed. RESULTS: Fifty-four consecutive patients with a chronic, patent false lumen in the descending aorta were included (35 surgically-treated type A AD with residual tear and 19 medically-treated type B AD). Median follow-up was 40 months. The in-plane rotational flow, pulse wave velocity and the percentage of thrombus in the false lumen were positively related to aortic growth rate (p = 0.006, 0.017, and 0.037, respectively), whereas wall shear stress showed a trend for a positive association (p = 0.060). These results were found irrespectively of the type of AD. CONCLUSIONS: In patients with chronic AD and patent false lumen of the descending aorta, rotational flow, pulse wave velocity and wall shear stress are positively related to aortic growth rate, and should be implemented in the follow-up algorithm of these patients. Further prospective studies are needed to confirm if the assessment of these parameters helps to identify patients at higher risk of adverse clinical events.


Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Rigidez Vascular , Disección Aórtica/diagnóstico por imagen , Humanos , Espectroscopía de Resonancia Magnética , Valor Predictivo de las Pruebas , Análisis de la Onda del Pulso
6.
Eur J Clin Microbiol Infect Dis ; 40(6): 1137-1148, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33404892

RESUMEN

The aim of the study was to analyze the epidemiological and clinical changes in EFIE. All definite IE episodes treated at a referral center between 2007 and 2018 were registered prospectively, and a trend test was used to study etiologies over time. EFIE cases were divided into three periods, and clinical differences between them were analyzed. All episodes of E. faecalis monomicrobial bacteremia (EFMB) between 2010 and 2018 and the percentage of echocardiograms performed were retrospectively collected. Six hundred forty-eight IE episodes were studied. We detected an increase in the percentage of EFIE (15% in 2007, 25.3% in 2018, P = 0.038), which became the most prevalent causative agent of IE during the last study period. One hundred and eight EFIE episodes were analyzed (2007-2010, n = 30; 2011-2014, n = 22; 2015-2018, n = 56). The patients in the last period were older (median 70.9 vs 66.5 vs 76.3 years, P = 0.015) and more frequently had an abdominal origin of EFIE (20% vs 13.6% vs 42.9%, P = 0.014), fewer indications for surgery (63.3% vs 54.6% vs 32.1%, P = 0.014), and non-significantly lower in-hospital mortality (30% vs 18.2% vs 12.5%, P = 0.139). There was an increase in the percentage of echocardiograms performed in patients with EFMB (30% in 2010, 51.2% in 2018, P = 0.014) and EFIE diagnoses (15% in 2010, 32.6% in 2018, P = 0.004). E. faecalis is an increasing cause of IE in our center, most likely due to an increase in the percentage of echocardiograms performed. The factors involved in clinical changes in EFIE should be thoroughly studied.


Asunto(s)
Endocarditis Bacteriana/microbiología , Enterococcus faecalis/aislamiento & purificación , Anciano , Anciano de 80 o más Años , Bacteriemia/epidemiología , Bacteriemia/microbiología , Bacteriemia/mortalidad , Endocarditis Bacteriana/epidemiología , Endocarditis Bacteriana/mortalidad , Enterococcus faecalis/clasificación , Enterococcus faecalis/genética , Enterococcus faecalis/fisiología , Femenino , Hospitales Universitarios/estadística & datos numéricos , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Derivación y Consulta/estadística & datos numéricos , Estudios Retrospectivos , España/epidemiología
7.
J Stroke Cerebrovasc Dis ; 26(5): 1110-1113, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28094188

RESUMEN

BACKGROUND: Stroke may be the first symptom of prosthetic valve thrombosis (PVT); therefore, rapid diagnosis and therapy are crucial. We aimed to evaluate the prevalence, main predictors, and long-term clinical evolution of patients with PVT in the acute phase of stroke. METHODS: We studied consecutive acute ischemic stroke patients with prosthetic heart valves who underwent emergent transesophageal echocardiography (TEE) during a 5-year period. Two groups were defined depending on the presence of PVT (PVT or non-PVT groups). Baseline characteristics, TEE findings, and international normalized ratios (INRs) at the stroke event were registered. Follow-up visits and TEE control examinations were performed. RESULTS: Sixty-seven patients were registered. TEE was performed within the first week in 85% of patients (n = 57). PVT was diagnosed in 41.8% of cases (n = 28). Clinical severity and baseline INR level showed no differences when the PVT and non-PVT groups were compared. The presence of PVT was associated with the mitral valve location as compared with the aortic valve location (75% versus 25%, P = .003), the presence of spontaneous echocontrast (64.3% versus 35.9%, P = .022), and low ejection fraction (66.7% versus 32.7%, P = .019). The PVT group showed a trend toward higher percentage of recurrence (10.7% versus 2.5%, P = .102) in the follow up period (mean follow-up 25 months). CONCLUSIONS: The detection of PVT in the acute stroke phase was relevant, as the stroke recurrence rate was considerable. Therefore, all patients with prosthetic heart valve should undergo emergent TEE.


Asunto(s)
Válvula Aórtica/cirugía , Isquemia Encefálica/epidemiología , Enfermedades de las Válvulas Cardíacas/epidemiología , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Válvula Mitral/cirugía , Accidente Cerebrovascular/epidemiología , Trombosis/epidemiología , Anciano , Válvula Aórtica/diagnóstico por imagen , Isquemia Encefálica/diagnóstico , Isquemia Encefálica/terapia , Bases de Datos Factuales , Ecocardiografía Transesofágica , Femenino , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/terapia , Humanos , Relación Normalizada Internacional , Masculino , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Prevalencia , Pronóstico , Recurrencia , Sistema de Registros , Estudios Retrospectivos , Factores de Riesgo , Índice de Severidad de la Enfermedad , España/epidemiología , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/terapia , Trombosis/diagnóstico por imagen , Trombosis/terapia , Factores de Tiempo
8.
Am J Cardiol ; 233: 11-18, 2024 Sep 26.
Artículo en Inglés | MEDLINE | ID: mdl-39332511

RESUMEN

Nonischemic dilated cardiomyopathy (NIDCM) is associated with an increased risk of atrial fibrillation (AF) and stroke, especially in patients with high CHA2DS2-VASc. We aimed to identify variables associated with incident AF or stroke using left atrial deformation analysis and its prognostic value added to CHA2DS2-VASc score. Patients with NIDCM and left ventricular ejection fraction <50% in sinus rhythm were included between January 2015 and December 2019. Left atrial volume index (LAVI) and atrial strain were used in combination with the CHA2DS2-VAS score to predict ischemic stroke or incident AF. Proportional hazards Cox regression was used to provide hazard ratios (HRs). There were 338 patients included. After a median follow-up of 3.6 years, the end point occurred in 41 patients (12.1%). LAVI outperformed other echocardiographic parameters, with a significant improvement in risk reclassification compared with CHA2DS2-VASc alone (net reclassification index 0.6, increase in Harrell's C from 0.63 to 0.73, p = 0.003), and remained significant after multivariate adjustment. LAVI was associated with both components of the end point separately. The best cutoff for LAVI was 44 ml/m2. LAVI ≥44 ml/m2 increased the risk of the end point among those with CHA2DS2-VASc ≥3 (HR 6.0, 95% confidence interval 2.6 to 13.5) but not in those with CHA2DS2-VASc <3 (HR 1.2, 95% confidence interval 0.3 to 4.5). Competing risk analysis did not alter the results. In conclusion, LAVI might be used to assess the risk of incident AF or stroke in NIDCM. Patients with LAVI ≥44 ml/m2 and CHA2DS2-VASc ≥3 could be at high risk of AF and stroke and may benefit from more intensive surveillance.

9.
Biomedicines ; 12(8)2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-39200177

RESUMEN

BACKGROUND: Longitudinal data on reverse cardiac remodeling and outcomes after transcatheter edge-to-edge repair (TEER) are limited. METHODS: A total of 78 patients with severe mitral regurgitation (MR) were included retrospectively. All patients had echocardiography at baseline and again six months after TEER. They were monitored for a primary composite endpoint, consisting of heart failure hospitalization and cardiovascular death, over 13 months. RESULTS: Significant decreases in the left ventricular ejection fraction (LVEF), all myocardial work indices (except global wasted work), and the left atrial reservoir were observed after TEER. Additionally, there was a decrease in the pulmonary artery systolic pressure and an increase in the tricuspid annular plane systolic excursion/pulmonary artery systolic pressure (TAPSE/PASP) ratio. A post-TEER TAPSE/PASP ratio of <0.47 (HR: 4.76, p-value = 0.039), and a post-TEER left atrial reservoir of <9.0% (HR: 2.77, p-value = 0.047) were associated with the primary endpoint. CONCLUSIONS: Echocardiography post-TEER reflects impairment in ventricular performance due to preload reduction and right ventricle and pulmonary artery coupling improvement. Short-term echocardiography after TEER identifies high-risk patients who could benefit from a close clinical follow-up. The prognostic significance of LA strain and the TAPSE/PASP ratio should be validated in subsequent large-scale prospective studies.

10.
Eur Heart J Imaging Methods Pract ; 2(1): qyae063, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-39224100

RESUMEN

Aims: Atrial fibrillation (AF) is a common comorbidity in non-ischaemic dilated cardiomyopathy (NIDCM) affecting conventional measures of left atrial (LA) function. We aimed to determine whether LA function analysis could identify patients at higher risk of major cardiovascular events (MACEs). Methods and results: A retrospective study of patients with NIDCM in AF referred to a single centre for transthoracic echocardiography (TTE) between 2015 and 2019. Peak atrial longitudinal strain (PALS) was measured along with LA emptying fraction and LA filling index (LAFI = E wave/PALS). Cox regression analysis was conducted. A total of 153 patients were included [median age 74 years, left ventricular ejection fraction (LVEF) 35%], and 57 (37.3%) had MACE after a median follow-up of 3.2 years. LAFI was the only independent TTE parameter associated with MACE after adjustment for age, diabetes, LVEF, left ventricular global longitudinal strain (LV-GLS), and LA volume index [adjusted hazard ratio (HR) = 1.02 per point increase, P = 0.024], with the best cut-off at ≥15. LAFI ≥15 predicted each of MACE components when separately analysed: MACE HR = 1.95, 95% confidence interval (CI) 1.16-3.30; cardiovascular death HR = 3.68, 95% CI 1.41-9.56, heart failure admission HR = 2.13, 95% CI 1.19-3.80, and ventricular arrhythmia HR = 4.72, 95% CI 1.52-14.67. Higher LAFI was associated with worsening LV-GLS, E/e', systolic pulmonary artery (PA) pressure, tricuspid annular plane systolic excursion, and right ventricular to PA coupling. Conclusion: LA deformation analysis is feasible in patients with NIDCM presenting with AF. LAFI may identify patients at higher risk of MACE and correlates with higher pulmonary pressures and worse right ventricular function, suggesting an elevation of left-sided ventricular pressures in patients with higher LAFI.

11.
Can J Cardiol ; 2023 Nov 25.
Artículo en Inglés | MEDLINE | ID: mdl-38013065

RESUMEN

BACKGROUND: Percutaneous mitral paravalvular leak (PVL) closure techniques are an effective and safe alternative to surgical treatment, but data regarding long-term outcomes are scarce. We aim to describe the impact of successful percutaneous mitral PVL closure on long-term outcomes. METHODS: All consecutive patients in whom a first-attempt percutaneous mitral PVL closure was performed in a single tertiary centre between January 2010 and October 2021 were included. Clinical variables, procedural details, and procedural success were collected. Patients were classified based on procedural success, defined as no more than mild residual leak. All-cause mortality was the primary endpoint. Cardiovascular death and heart failure hospitalizations (HFHs) were key secondary endpoints. RESULTS: Ninety patients (median age 72.5 years [66.0-78.4]; median EuroSCORE-II 8.2 [5.3-12.46]) were included. Although reduction of at least 1 degree in PVL severity was achieved in 82 (91.1%), procedural success was achieved in 47 (52.2%). Chronic kidney disease, previous surgery for PVL, and the presence of multiple jets were independently associated with procedural failure. After a median follow-up of 3.2 (1.2-5.2) years, mortality rate was higher in the procedural failure group (27.3 per 100 patients-years) compared with the group with successful closure (8.2 per 100 patient-years). Procedural failure was associated with all-cause death (adjusted hazard ratio [aHR], 2.59; 95% confidence interval [CI], 1.41-4.78), cardiovascular death (aHR, 3.53; 95% CI, 1.67-7.49) and HFH (aHR, 3.27; 95% CI,1.72-6.20). CONCLUSIONS: A successful reduction in PVL to mild or absent is associated with improved rates of all-cause death, cardiovascular death, and HFHs.

12.
Eur Heart J Cardiovasc Imaging ; 24(8): 1120-1128, 2023 07 24.
Artículo en Inglés | MEDLINE | ID: mdl-37131301

RESUMEN

AIMS: To assess the progression of the disease and evolution of the main echocardiographic variables for quantifying AS in patients with severe low-flow low-gradient (LFLG) AS compared to other severe AS subtypes. METHODS AND RESULTS: Longitudinal, observational, multicenter study including consecutive asymptomatic patients with severe AS (aortic valve area, AVA < 1.0 cm²) and normal left ventricle ejection fraction (LVEF ≥ 50%). Patients were classified according to baseline echocardiography into: HG (high gradient; mean gradient ≥ 40 mmHg), NFLG (normal-flow low-gradient; mean gradient < 40 mmHg, indexed systolic volume (SVi) > 35mL/m2), or LFLG (mean gradient < 40 mmHg, SVi ≤ 35 mL/m²). AS progression was analyzed by comparing patients' baseline measurements and their last follow-up measurements or those taken prior to aortic valve replacement (AVR). Of the 903 included patients, 401 (44.4%) were HG, 405 (44.9%) NFLG, and 97 (10.7%) LFLG. Progression of the mean gradient in a linear mixed regression model was greater in low-gradient groups: LFLG vs. HG (regression coefficient 0.124, P = 0.005) and NFLG vs. HG (regression coefficient 0.068, P = 0.018). No differences were observed between the LFLG and NFLG groups (regression coefficient 0.056, P = 0.195). However, AVA reduction was slower in the LFLG group compared to the NFLG (P < 0.001). During follow-up, in conservatively-managed patients, 19.1% (n = 9) of LFLG patients evolved to having NFLG AS and 44.7% (n = 21) to having HG AS. In patients undergoing AVR, 58.0% (n = 29) of LFLG baseline patients received AVR with a HG AS. CONCLUSION: LFLG AS shows an intermediate AVA and gradient progression compared to NFLG and HG AS. The majority of patients initially classified as having LFLG AS changed over time to having other severe forms of AS, and most of them received AVR with a HG AS.


Asunto(s)
Estenosis de la Válvula Aórtica , Humanos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Ecocardiografía , Válvula Aórtica/diagnóstico por imagen , Función Ventricular Izquierda , Volumen Sistólico , Índice de Severidad de la Enfermedad , Resultado del Tratamiento , Estudios Retrospectivos
13.
J Clin Med ; 11(2)2022 Jan 17.
Artículo en Inglés | MEDLINE | ID: mdl-35054153

RESUMEN

Multimodality imaging is the basis of the diagnosis, follow-up, and surgical management of bicuspid aortic valve (BAV) patients. Transthoracic echocardiography (TTE) is used in our clinical routine practice as a first line imaging for BAV diagnosis, valvular phenotyping and function, measurement of thoracic aorta, exclusion of other aortic malformations, and for the assessment of complications such are infective endocarditis and aortic. Nevertheless, TTE is less useful if we want to assess accurately other aortic segments such as mid-distal ascending aorta, where computed tomography (CT) and magnetic resonance (CMR) could improve the precision of aorta size measurement by multiplanar reconstructions. A major advantage of CT is its superior spatial resolution, which affords a better definition of valve morphology and calcification, accuracy, and reproducibility of ascending aorta size, and allows for coronary artery assessment. Moreover, CMR offers the opportunity of being able to evaluate aortic functional properties and blood flow patterns. In this setting, new developed sequences such as 4D-flow may provide new parameters to predict events during follow up. The integration of all multimodality information facilitates a comprehensive evaluation of morphologic and dynamic features, stratification of the risk, and therapy guidance of this cohort of patients.

14.
Int J Cardiol ; 360: 104-110, 2022 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-35490788

RESUMEN

AIMS: We sought to determine, using advanced echocardiography, the prevalence and type of cardiovascular sequelae after COVID19 infection with marked elevation of cardiovascular biomarkers (CVB), and their prognostic implications. METHODS: All patients admitted from March 1st to May 25th, 2020 to a tertiary referral hospital were included. Those with cardiovascular diseases or dead during admission were excluded. Patients with hs-TnI > 45 ng/L, NT-proBNP>300 pg/mL, and D-dimer >8000 ng/mL were matched with COVID controls (three biomarkers within the normal range) based on intensive care requirements and age, and separately analyzed. RESULTS: From 2025 patients, 80 patients with significantly elevated CVB and 29 controls were finally included. No differences in baseline characteristics were observed among groups, but elevated CVB patients were sicker. Follow-up echocardiograms showed no differences among groups regarding LVEF and only slight differences between groups within the normal range. Hs-TnI patients had lower myocardial work and longitudinal strain. The presence of an abnormal echocardiogram was more frequent in the elevated CVB group compared to controls (23.8 vs 10.3%, P = 0.123) but mainly associated with mild abnormalities in deformation parameters. Management did not change in any case and no major cardiovascular events except deep vein thrombosis occurred after a median follow-up of 7 months. CONCLUSION: Minimal abnormalities in cardiac structure and function are observed in COVID19 survivors without previous cardiovascular diseases who presented a significant CVB rise at admission, with no impact on patient management or short-term prognosis. These results do not support a routine screening program after discharge in this population.


Asunto(s)
COVID-19 , Enfermedades Cardiovasculares , Biomarcadores , COVID-19/diagnóstico por imagen , Enfermedades Cardiovasculares/diagnóstico por imagen , Enfermedades Cardiovasculares/epidemiología , Ecocardiografía , Humanos , Péptido Natriurético Encefálico , Fragmentos de Péptidos , Pronóstico , Sobrevivientes
15.
JACC Cardiovasc Imaging ; 15(1): 46-56, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34801463

RESUMEN

OBJECTIVES: This study sought to assess the predictive value of wall shear stress (WSS) for colocalized ascending aorta (AAo) growth rate (GR) in patients with bicuspid aortic valve (BAV). BACKGROUND: BAV is associated with AAo dilation, but there is limited knowledge about possible predictors of aortic dilation in patients with BAV. An increased WSS has been related to aortic wall damage in patients with BAV, but no previous prospective study tested its predictive value for dilation rate. Recently, a registration-based technique for the semiautomatic mapping of aortic GR has been presented and validated. METHODS: Forty-seven patients with BAV free from valvular dysfunction prospectively underwent 4-dimensional flow cardiac magnetic resonance to compute WSS and subsequent follow-up with 2 electrocardiogram-gated high-resolution contrast-enhanced computed tomography angiograms for GR assessment. RESULTS: During a median follow-up duration of 43 months, mid AAo GR was 0.24 mm/year. WSS and its circumferential component showed statistically significant association with mid AAo GR in bivariate (P = 0.049 and P = 0.014, respectively) and in multivariate analysis corrected for stroke volume and either baseline AAo diameter (P = 0.046 and P = 0.014, respectively) or z-score (P = 0.036 and P = 0.012, respectively). GR mapping further detailed that GR was heterogeneous in the AAo and that circumferential WSS, but not WSS magnitude, showed statistically significant positive associations with GR in the regions with the fastest growth. CONCLUSIONS: 4D flow cardiac magnetic resonance-derived WSS and, in particular, its circumferential component predict progressive dilation of the ascending aorta in patients with BAV. Thus, the assessment of WSS may be considered in the follow-up of these patients.


Asunto(s)
Enfermedad de la Válvula Aórtica Bicúspide , Enfermedades de las Válvulas Cardíacas , Válvula Aórtica/diagnóstico por imagen , Dilatación , Hemodinámica , Humanos , Valor Predictivo de las Pruebas
16.
Front Cardiovasc Med ; 9: 852954, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35433871

RESUMEN

Objectives: To determine the risk of mortality and need for aortic valve replacement (AVR) in patients with low-flow low-gradient (LFLG) aortic stenosis (AS). Methods: A longitudinal multicentre study including consecutive patients with severe AS (aortic valve area [AVA] < 1.0 cm2) and normal left ventricular ejection fraction (LVEF). Patients were classified as: high-gradient (HG, mean gradient ≥ 40 mmHg), normal-flow low-gradient (NFLG, mean gradient < 40 mmHg, indexed systolic volume (SVi) > 35 ml/m2) and LFLG (mean gradient < 40 mmHg, SVi ≤ 35 ml/m2). Results: Of 1,391 patients, 147 (10.5%) had LFLG, 752 (54.1%) HG, and 492 (35.4%) NFLG. Echocardiographic parameters of the LFLG group showed similar AVA to the HG group but with less severity in the dimensionless index, calcification, and hypertrophy. The HG group required AVR earlier than NFLG (p < 0.001) and LFLG (p < 0.001), with no differences between LFLG and NFLG groups (p = 0.358). Overall mortality was 27.7% (CI 95% 25.3-30.1) with no differences among groups (p = 0.319). The impact of AVR in terms of overall mortality reduction was observed the most in patients with HG (hazard ratio [HR]: 0.17; 95% CI: 0.12-0.23; p < 0.001), followed by patients with LFLG (HR: 0.25; 95% CI: 0.13-0.49; p < 0.001), and finally patients with NFLG (HR: 0.29; 95% CI: 0.20-0.44; p < 0.001), with a risk reduction of 84, 75, and 71%, respectively. Conclusions: Paradoxical LFLG AS affects 10.5% of severe AS, and has a lower need for AVR than the HG group and similar to the NFLG group, with no differences in mortality. AVR had a lower impact on LFLG AS compared with HG AS. Therefore, the findings of the present study showed LFLG AS to have an intermediate clinical risk profile between the HG and NFHG groups.

17.
JACC Case Rep ; 3(4): 566-572, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33821246

RESUMEN

We present a case of acute myocarditis with left ventricular dysfunction and intracavitary thrombosis in a 55-year-old man with severe acute respiratory syndrome coronavirus 2 infection (coronavirus disease 2019) who was admitted with bilateral atypical pneumonia. The patient was treated with anticoagulation and optimal heart failure therapy and had an improvement of left ventricular function and thrombus resolution. (Level of Difficulty: Intermediate.).

18.
Int J Cardiol Heart Vasc ; 32: 100721, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33604450

RESUMEN

PURPOSE: To compare performance of visual and quantitative analyses for detecting myocardial ischaemia from single- and dual-energy computed tomography (CT) in patients with suspected coronary artery disease (CAD). METHODS: Eighty-four patients with suspected CAD were scheduled for dual-energy cardiac CT at rest (CTA) and pharmacological stress (CTP). Myocardial CT perfusion was analysed visually and using three parameters: mean attenuation density (MA), transmural perfusion ratio (TPR) and myocardial perfusion reserve index (MPRI), on both single-energy CT and CT-based iodine images. Significant CAD was defined in AHA-segments by concomitant myocardial hypoperfusion identified visually or quantitatively (parameter < threshold) and coronary stenosis detected by CTA. Single-photon emission CT and invasive coronary angiography were used as reference. Perfusion-parameter cut-off values were calculated in a randomly-selected subgroup of 30 patients. RESULTS: The best-performing thresholds for TPR, MPRI and MA were 0.96, 23 and 0.5 for single-energy CT and 0.97, 47 and 0.3 for iodine imaging. For both CT-imaging modalities, TPR yielded the highest area under receiver operating characteristic curve (AUC) (0.99 and 0.97 for single-energy CT and iodine imaging, respectively, in vessel-based analysis) compared to visual analysis, MA and MPRI. Visual interpretation on iodine imaging resulted in higher AUC compared to that on single-energy CT in per-vessel (AUC: 0.93 vs 0.86, respectively) and per-patient (0.94 vs 0.93) analyses. CONCLUSION: Transmural perfusion ratio on both CT-imaging modalities is the best-performing parameter for detecting myocardial ischaemia compared to visual method and other perfusion parameters. Visual analysis on CT-based iodine imaging outperforms that on single-energy CT.

19.
J Clin Med ; 10(22)2021 Nov 14.
Artículo en Inglés | MEDLINE | ID: mdl-34830571

RESUMEN

Ascending aorta diameters have important clinical value in the diagnosis, follow-up, and surgical indication of many aortic diseases. However, there is no uniformity among experts regarding ascending aorta diameter quantification by echocardiography. The aim of this study was to compare maximum aortic root and ascending aorta diameters determined by the diastolic leading edge (DLE) and the systolic inner edge (SIE) conventions in adult and pediatric patients with inherited cardiovascular diseases. Transthoracic echocardiograms were performed in 328 consecutive patients (260 adults and 68 children). Aorta diameters were measured twice at the root and ascending aorta by the DLE convention following the 2015 American Society of Echocardiography (ASE) adult guidelines and the SIE convention following the 2010 ASE pediatric guidelines. Comparison of the diameters measured by the two conventions in the overall population showed a non-significant underestimation of the diameter measured by the SIE convention at root level of 0.28 mm (CI -1.36; 1.93) and at tubular ascending aorta level of 0.17 mm (CI -1.69; 2.03). Intraobserver and interobserver variability were excellent. Maximum aorta diameter measured by the leading edge convention in end-diastole and the inner edge convention in mid-systole had similar values to a mild non-significant underestimation of the inner-to-inner method that permits them to be interchangeable when used in clinical practice.

20.
J Clin Med ; 10(22)2021 Nov 12.
Artículo en Inglés | MEDLINE | ID: mdl-34830543

RESUMEN

In acute ST-segment elevation myocardial infarction (STEMI) late gadolinium enhancement (LGE) may underestimate segmental functional recovery. We evaluated the predictive value of cardiac magnetic resonance (CMR) feature-tracking (FT) for functional recovery and whether it incremented the value of LGE compared to low-dose dobutamine stress echocardiography (LDDSE) and speckle-tracking echocardiography (STE). Eighty patients underwent LDDSE and CMR within 5-7 days after STEMI and segmental functional recovery was defined as improvement in wall-motion at 6-months CMR. Optimal conventional and FT parameters were analyzed and then also applied to an external validation cohort of 222 STEMI patients. Circumferential strain (CS) was the strongest CMR-FT predictor and addition to LGE increased the overall accuracy to 74% and was especially relevant in segments with 50-74% LGE (AUC 0.60 vs. 0.75, p = 0.001). LDDSE increased the overall accuracy to 71%, and in the 50-74% LGE subgroup improved the AUC from 0.60 to 0.69 (p = 0.039). LGE + CS showed similar value as LGE + LDDSE. In the validation cohort, CS was also the strongest CMR-FT predictor of recovery and addition of CS to LGE improved overall accuracy to 73% although this difference was not significant (AUC 0.69, p = 0.44). Conclusion: CS is the strongest CMR-FT predictor of segmental functional recovery after STEMI. Its incremental value to LGE is comparable to that of LDDSE whilst avoiding an inotropic stress agent. CS is especially relevant in segments with 50-74% LGE where accuracy is lower and further testing is frequently required to clarify the potential for recovery.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA