Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 71
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Cell ; 152(1-2): 25-38, 2013 Jan 17.
Artículo en Inglés | MEDLINE | ID: mdl-23273993

RESUMEN

Cell-type plasticity within a tumor has recently been suggested to cause a bidirectional conversion between tumor-initiating stem cells and nonstem cells triggered by an inflammatory stroma. NF-κB represents a key transcription factor within the inflammatory tumor microenvironment. However, NF-κB's function in tumor-initiating cells has not been examined yet. Using a genetic model of intestinal epithelial cell (IEC)-restricted constitutive Wnt-activation, which comprises the most common event in the initiation of colon cancer, we demonstrate that NF-κB modulates Wnt signaling and show that IEC-specific ablation of RelA/p65 retards crypt stem cell expansion. In contrast, elevated NF-κB signaling enhances Wnt activation and induces dedifferentiation of nonstem cells that acquire tumor-initiating capacity. Thus, our data support the concept of bidirectional conversion and highlight the importance of inflammatory signaling for dedifferentiation and generation of tumor-initiating cells in vivo.


Asunto(s)
Desdiferenciación Celular , Transformación Celular Neoplásica , Neoplasias del Colon/patología , Células Madre Neoplásicas/patología , Animales , Colon/patología , Células Epiteliales/patología , Femenino , Humanos , Masculino , Ratones , FN-kappa B/metabolismo , Vía de Señalización Wnt
2.
Ther Umsch ; 80(4): 204-208, 2023.
Artículo en Alemán | MEDLINE | ID: mdl-37122179

RESUMEN

An MRI for Every Patient with Back Pain? Abstract. Imaging in spinal disorders has changed in the past years. Improved MRI techniques allow for better image interpretation. Unchanged, however, close correlation between clinical evaluation and imaging results remains crucial for correct diagnoses and subsequent therapeutical decisions. Reimbursement cuts have made MRI more affordable in Switzerland while being widely available. This allows - if used according to guidelines - for optimal treatment of patients with spinal disorders.


Asunto(s)
Dolor de Espalda , Imagen por Resonancia Magnética , Humanos , Dolor de Espalda/diagnóstico por imagen , Suiza
3.
Radiology ; 303(1): 119-127, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35014904

RESUMEN

Background Dark-field chest radiography allows for assessment of lung alveolar structure by exploiting wave optical properties of x-rays. Purpose To evaluate the qualitative and quantitative features of dark-field chest radiography in participants with pulmonary emphysema as compared with those in healthy control subjects. Materials and Methods In this prospective study conducted from October 2018 to October 2020, participants aged at least 18 years who underwent clinically indicated chest CT were screened for participation. Inclusion criteria were an ability to consent to the procedure and stand upright without help. Exclusion criteria were pregnancy, serious medical conditions, and any lung condition besides emphysema that was visible on CT images. Participants were examined with a clinical dark-field chest radiography prototype that simultaneously acquired both attenuation-based radiographs and dark-field chest radiographs. Dark-field coefficients were tested for correlation with each participant's CT-based emphysema index using the Spearman correlation test. Dark-field coefficients of adjacent groups in the semiquantitative Fleischner Society emphysema grading system were compared using a Wilcoxon Mann-Whitney U test. The capability of the dark-field coefficient to enable detection of emphysema was evaluated with receiver operating characteristics curve analysis. Results A total of 83 participants (mean age, 65 years ± 12 [standard deviation]; 52 men) were studied. When compared with images from healthy participants, dark-field chest radiographs in participants with emphysema had a lower and inhomogeneous dark-field signal intensity. The locations of focal signal intensity loss on dark-field images corresponded well with emphysematous areas found on CT images. The dark-field coefficient was negatively correlated with the quantitative CT-based emphysema index (r = -0.54, P < .001). Participants with Fleischner Society grades of mild, moderate, confluent, or advanced destructive emphysema exhibited a lower dark-field coefficient than those without emphysema (eg, 1.3 m-1 ± 0.6 for participants with confluent or advanced destructive emphysema vs 2.6 m-1 ± 0.4 for participants without emphysema; P < .001). The area under the receiver operating characteristic curve for detection of mild emphysema was 0.79. Conclusion Pulmonary emphysema leads to reduced signal intensity on dark-field chest radiographs, showing the technique has potential as a diagnostic tool in the assessment of lung diseases. © RSNA, 2022 See also the editorial by Hatabu and Madore in this issue.


Asunto(s)
Enfisema , Enfisema Pulmonar , Adolescente , Adulto , Anciano , Enfisema/diagnóstico por imagen , Femenino , Humanos , Pulmón/diagnóstico por imagen , Masculino , Estudios Prospectivos , Enfisema Pulmonar/diagnóstico por imagen , Radiografía , Radiografía Torácica/métodos
5.
Eur Radiol ; 32(7): 4738-4748, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35258673

RESUMEN

OBJECTIVES: To evaluate the performance and reproducibility of MR imaging features in the diagnosis of joint invasion (JI) by malignant bone tumors. METHODS: MR images of patients with and without JI (n = 24 each), who underwent surgical resection at our institution, were read by three radiologists. Direct (intrasynovial tumor tissue (ITT), intraarticular destruction of cartilage/bone, invasion of capsular/ligamentous insertions) and indirect (tumor size, signal alterations of epiphyseal/transarticular bone (bone marrow replacement/edema-like), synovial contrast enhancement, joint effusion) signs of JI were assessed. Odds ratios, sensitivity, specificity, PPV, NPV, and reproducibilities (Cohen's and Fleiss' κ) were calculated for each feature. Moreover, the diagnostic performance of combinations of direct features was assessed. RESULTS: Forty-eight patients (28.7 ± 21.4 years, 26 men) were evaluated. All readers reliably assessed the presence of JI (sensitivity = 92-100 %; specificity = 88-100%, respectively). Best predictors for JI were direct visualization of ITT (OR = 186-229, p < 0.001) and destruction of intraarticular bone (69-324, p < 0.001). Direct visualization of ITT was also highly reliable in assessing JI (sensitivity, specificity, PPV, NPV = 92-100 %), with excellent reproducibility (κ = 0.83). Epiphyseal bone marrow replacement and synovial contrast enhancement were the most sensitive indirect signs, but lacked specificity (29-54%). By combining direct signs with high specificity, sensitivity was increased (96 %) and specificity (100 %) was maintained. CONCLUSION: JI by malignant bone tumors can reliably be assessed on preoperative MR images with high sensitivity, specificity, and reproducibility. Particularly direct visualization of ITT, destruction of intraarticular bone, and a combination of highly specific direct signs were valuable, while indirect signs were less predictive and specific. KEY POINTS: • Direct visualization of intrasynovial tumor was the single most sensitive and specific (92-100%) MR imaging sign of joint invasion. • Indirect signs of joint invasion, such as joint effusion or synovial enhancement, were less sensitive and specific compared to direct signs. • A combination of the most specific direct signs of joint invasion showed best results with perfect specificity and PPV (both 100%) and excellent sensitivity and NPV (both 96 %).


Asunto(s)
Neoplasias Óseas , Neoplasias Óseas/diagnóstico , Humanos , Ligamentos Articulares/patología , Imagen por Resonancia Magnética/métodos , Masculino , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
6.
Radiology ; 301(2): 389-395, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34427464

RESUMEN

Background X-ray dark-field radiography takes advantage of the wave properties of x-rays, with a relatively high signal in the lungs due to the many air-tissue interfaces in the alveoli. Purpose To describe the qualitative and quantitative characteristics of x-ray dark-field images in healthy human subjects. Materials and Methods Between October 2018 and January 2020, patients of legal age who underwent chest CT as part of their diagnostic work-up were screened for study participation. Inclusion criteria were a normal chest CT scan, the ability to consent, and the ability to stand upright without help. Exclusion criteria were pregnancy, serious medical conditions, and changes in the lung tissue, such as those due to cancer, pleural effusion, atelectasis, emphysema, infiltrates, ground-glass opacities, or pneumothorax. Images of study participants were obtained by using a clinical x-ray dark-field prototype, recently constructed and commissioned at the authors' institution, to simultaneously acquire both attenuation-based and dark-field thorax radiographs. Each subject's total dark-field signal was correlated with his or her lung volume, and the dark-field coefficient was correlated with age, sex, weight, and height. Results Overall, 40 subjects were included in this study (average age, 62 years ± 13 [standard deviation]; 26 men, 14 women). Normal human lungs have high signal, while the surrounding osseous structures and soft tissue have very low and no signal, respectively. The average dark-field signal was 2.5 m-1 ± 0.4 of examined lung tissue. There was a correlation between the total dark-field signal and the lung volume (r = 0.61, P < .001). No difference was found between men and women (P = .78). Also, age (r = -0.18, P = .26), weight (r = 0.24, P = .13), and height (r = 0.01, P = .96) did not influence dark-field signal. Conclusion This study introduces qualitative and quantitative values for x-ray dark-field imaging in healthy human subjects. The quantitative x-ray dark-field coefficient is independent from demographic subject parameters, emphasizing its potential in diagnostic assessment of the lung. ©RSNA, 2021 See also the editorial by Hatabu and Madore in this issue.


Asunto(s)
Pulmón/anatomía & histología , Radiografía Torácica/métodos , Tomografía Computarizada por Rayos X/métodos , Anciano , Estudios de Evaluación como Asunto , Femenino , Humanos , Pulmón/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Investigación Cualitativa , Valores de Referencia
7.
Eur Radiol ; 31(6): 4175-4183, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33211140

RESUMEN

OBJECTIVE: Assessing the advantage of x-ray dark-field contrast over x-ray transmission contrast in radiography for the detection of developing radiation-induced lung damage in mice. METHODS: Two groups of female C57BL/6 mice (irradiated and control) were imaged obtaining both contrasts monthly for 28 weeks post irradiation. Six mice received 20 Gy of irradiation to the entire right lung sparing the left lung. The control group of six mice was not irradiated. A total of 88 radiographs of both contrasts were evaluated for both groups based on average values for two regions of interest, covering (irradiated) right lung and healthy left lung. The ratio of these average values, R, was distinguished between healthy and damaged lungs for both contrasts. The time-point when deviations of R from healthy lung exceeded 3σ was determined and compared among contrasts. The Wilcoxon-Mann-Whitney test was used to test against the null hypothesis that there is no difference between both groups. A selection of 32 radiographs was assessed by radiologists. Sensitivity and specificity were determined in order to compare the diagnostic potential of both contrasts. Inter-reader and intra-reader accuracy were rated with Cohen's kappa. RESULTS: Radiation-induced morphological changes of lung tissue caused deviations from the control group that were measured on average 10 weeks earlier with x-ray dark-field contrast than with x-ray transmission contrast. Sensitivity, specificity, and accuracy doubled using dark-field radiography. CONCLUSION: X-ray dark-field radiography detects morphological changes of lung tissue associated with radiation-induced damage earlier than transmission radiography in a pre-clinical mouse model. KEY POINTS: • Significant deviations from healthy lung due to irradiation were measured after 16 weeks with x-ray dark-field radiography (p = 0.004). • Significant deviations occur on average 10 weeks earlier for x-ray dark-field radiography in comparison to x-ray transmission radiography. • Sensitivity and specificity doubled when using x-ray dark-field radiography instead of x-ray transmission radiography.


Asunto(s)
Pulmón , Animales , Femenino , Pulmón/diagnóstico por imagen , Ratones , Ratones Endogámicos C57BL , Radiografía , Sensibilidad y Especificidad , Rayos X
8.
Eur Radiol ; 29(11): 5950-5960, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31073861

RESUMEN

OBJECTIVES: Evaluation of sparse sampling computed tomography (SpSCT) regarding subjective and objective image criteria for the detection of pulmonary embolism (PE) at different simulated dose levels. METHODS: Computed tomography pulmonary angiography (CTPA) scans of 20 clinical patients were used to obtain simulated low-dose scans with 100%-50%-25%-12.5%-6.3%-3.1% of the clinical dose, resulting in a total of six dose levels (DL). From these full sampling (FS) data, every second (2-SpSCT) or fourth (4-SpSCT) projection was used to obtain simulated sparse sampling scans. Each image set was evaluated by four blinded radiologists regarding subjective image criteria (artifacts, image quality) and diagnostic performance (confidence, sensitivity, specificity, accuracy, and area under the curve). Additionally, the contrast-to-noise ratio (CNR) was evaluated for objective image quality. RESULTS: Sensitivity was 100% with 2-SpSCT and 4-SpSCT at the 25% DL and the 12.5% DL for all localizations of PE (one subgroup 98.5%). With FS, the sensitivity decreased to 90% at the 12.5% DL. 2-SpSCT and 4-SpSCT showed higher values for sensitivity, specificity, accuracy, and the area under the curve at all DL compared with FS. Subjective image quality was significantly higher for 4-SpSCT compared with FS at each dose level (p < 0.01, paired t test). Only with 4-SpSCT, all examinations were rated as showing diagnostic image quality at the 12.5% DL. CONCLUSIONS: Via SpSCT, a dose reduction down to a 12.5% dose level (corresponding to a mean effective dose of 0.38 mSv in the current study) for CTPA is possible while maintaining high image quality and full diagnostic confidence. KEY POINTS: • With sparse sampling CT, radiation dose could be significantly reduced in clinical routine. • Sparse sampling CT is a novel hardware solution with which less projection images are acquired. • In the current study, a dose reduction of 87.5% (corresponding to a mean effective dose of 0.38 mSv) for CTPA could be achieved while maintaining excellent diagnostic performance.


Asunto(s)
Angiografía por Tomografía Computarizada/métodos , Embolia Pulmonar/diagnóstico por imagen , Análisis de Varianza , Artefactos , Estudios de Factibilidad , Humanos , Pulmón/diagnóstico por imagen , Seguridad del Paciente , Dosis de Radiación , Sensibilidad y Especificidad
9.
Eur Radiol ; 29(9): 4624-4634, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-30758656

RESUMEN

OBJECTIVES: To develop and evaluate a method for areal bone mineral density (aBMD) measurement based on dual-layer spectral CT scout scans. METHODS: A post-processing algorithm using a pair of 2D virtual mono-energetic scout images (VMSIs) was established in order to semi-automatically compute the aBMD at the spine similarly to DXA, using manual soft tissue segmentation, semi-automatic segmentation for the vertebrae, and automatic segmentation for the background. The method was assessed based on repetitive measurements of the standardized European Spine Phantom (ESP) using the standard scout scan tube current (30 mA) and other tube currents (10 to 200 mA), as well as using fat-equivalent extension rings simulating different patient habitus, and was compared to dual-energy X-ray absorptiometry (DXA). Moreover, the feasibility of the method was assessed in vivo in female patients. RESULTS: Derived from standard scout scans, aBMD values measured with the proposed method significantly correlated with DXA measurements (r = 0.9925, p < 0.001), and mean accuracy (DXA, 4.12%; scout, 1.60%) and precision (DXA, 2.64%; scout, 2.03%) were comparable between the two methods. Moreover, aBMD values assessed at different tube currents did not differ significantly (p ≥ 0.20 for all), suggesting that the presented method could be applied to scout scans with different settings. Finally, data derived from sample patients were concordant with BMD values from a reference age-matched population. CONCLUSIONS: Based on dual-layer spectral scout scans, aBMD measurements were fast and reliable and significantly correlated with the according DXA measurements in phantoms. Considering the number of CT acquisitions performed worldwide, this method could allow truly opportunistic osteoporosis screening. KEY POINTS: • 2D scout scans (localizer radiographs) from a dual-layer spectral CT scanner, which are mandatory parts of a CT examination, can be used to automatically determine areal bone mineral density (aBMD) at the spine. • The presented method allowed fast (< 25 s/patient), semi-automatic, and reliable DXA-equivalent aBMD measurements for state-of-the-art DXA phantoms at different tube settings and for various patient habitus, as well as for sample patients. • Considering the number of CT scout scan acquisitions performed worldwide on a daily basis, the presented technique could enable truly opportunistic osteoporosis screening with DXA-equivalent metrics, without involving higher radiation exposure since it only processes existing data that is acquired during each CT scan.


Asunto(s)
Densidad Ósea/fisiología , Osteoporosis/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Adulto , Factores de Edad , Anciano , Algoritmos , Estudios de Factibilidad , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Persona de Mediana Edad , Fantasmas de Imagen , Reproducibilidad de los Resultados , Columna Vertebral/diagnóstico por imagen , Adulto Joven
11.
Eur Radiol ; 28(7): 2743-2744, 2018 07.
Artículo en Inglés | MEDLINE | ID: mdl-29637267

RESUMEN

This editorial comment refers to the article: Can We Perform CT of the Appendix with Less than 1 mSv? A De-escalating Dose-simulation Study. Park JH, et al., Eur Radiol, Dec 7, 2017.


Asunto(s)
Apéndice , Abdomen , Tomografía Computarizada por Rayos X
12.
Eur Radiol ; 28(9): 3702-3709, 2018 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-29600475

RESUMEN

OBJECTIVES: To evaluate whether template-based structured reports (SRs) add clinical value to primary CT staging in patients with diffuse large B-cell lymphoma (DLBCL) compared to free-text reports (FTRs). METHODS: In this two-centre study SRs and FTRs were acquired for 16 CT examinations. Thirty-two reports were independently scored by four haematologists using a questionnaire addressing completeness of information, structure, guidance for patient management and overall quality. The questionnaire included yes-no, 10-point Likert scale and 5-point scale questions. Altogether 128 completed questionnaires were evaluated. Non-parametric Wilcoxon signed-rank test and McNemar's test were used for statistical analysis. RESULTS: SRs contained information on affected organs more often than FTRs (95 % vs. 66 %). More SRs commented on extranodal involvement (91 % vs. 62 %). Sufficient information for Ann-Arbor classification was included in more SRs (89 % vs. 64 %). Information extraction was quicker from SRs (median rating on 10-point Likert scale=9 vs. 6; 7-10 vs. 4-8 interquartile range). SRs had better comprehensibility (9 vs. 7; 8-10 vs. 5-8). Contribution of SRs to clinical decision-making was higher (9 vs. 6; 6-10 vs. 3-8). SRs were of higher quality (p < 0.001). All haematologists preferred SRs over FTRs. CONCLUSIONS: Structured reporting of CT examinations for primary staging in patients with DLBCL adds clinical value compared to FTRs by increasing completeness of reports, facilitating information extraction and improving patient management. KEY POINTS: • Structured reporting in CT helps clinicians to assess patients with lymphoma. • This two-centre study showed that structured reporting improves information content and extraction. • Patient management may be improved by structured reporting. • Clinicians preferred structured reports over free-text reports.


Asunto(s)
Linfoma de Células B Grandes Difuso/diagnóstico por imagen , Linfoma de Células B Grandes Difuso/patología , Registros Médicos , Tomografía Computarizada por Rayos X/métodos , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Comunicación Interdisciplinaria , Masculino , Persona de Mediana Edad , Estadificación de Neoplasias , Reproducibilidad de los Resultados , Estudios Retrospectivos , Encuestas y Cuestionarios
13.
Eur Radiol ; 28(8): 3318-3325, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-29460069

RESUMEN

OBJECTIVES: After endovascular aortic repair (EVAR), discrimination of endoleaks and intra-aneurysmatic calcifications within the aneurysm often requires multiphase computed tomography (CT). Spectral photon-counting CT (SPCCT) in combination with a two-contrast agent injection protocol may provide reliable detection of endoleaks with a single CT acquisition. METHODS: To evaluate the feasibility of SPCCT, the stent-lined compartment of an abdominal aortic aneurysm phantom was filled with a mixture of iodine and gadolinium mimicking enhanced blood. To represent endoleaks of different flow rates, the adjacent compartments contained either one of the contrast agents or calcium chloride to mimic intra-aneurysmatic calcifications. After data acquisition with a SPCCT prototype scanner with multi-energy bins, material decomposition was performed to generate iodine, gadolinium and calcium maps. RESULTS: In a conventional CT slice, Hounsfield units (HU) of the compartments were similar ranging from 147 to 168 HU. Material-specific maps differentiate the distributions within the compartments filled with iodine, gadolinium or calcium. CONCLUSION: SPCCT may replace multiphase CT to detect endoleaks without sacrificing diagnostic accuracy. It is a unique feature of our method to capture endoleak dynamics and allow reliable distinction from intra-aneurysmatic calcifications in a single scan, thereby enabling a significant reduction of radiation exposure. KEY POINTS: • SPCCT might enable advanced endoleak detection. • Material maps derived from SPCCT can differentiate iodine, gadolinium and calcium. • SPCCT may potentially reduce radiation burden for EVAR patients under post-interventional surveillance.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Medios de Contraste , Endofuga/diagnóstico por imagen , Procedimientos Endovasculares/métodos , Fotones , Tomografía Computarizada por Rayos X/métodos , Anciano , Anciano de 80 o más Años , Estudios de Factibilidad , Femenino , Gadolinio , Humanos , Masculino , Persona de Mediana Edad , Fantasmas de Imagen , Stents
14.
Eur Radiol ; 28(7): 2745-2755, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-29404773

RESUMEN

OBJECTIVES: Evaluation of imaging performance across dual-energy CT (DECT) platforms, including dual-layer CT (DLCT), rapid-kVp-switching CT (KVSCT) and dual-source CT (DSCT). METHODS: A semi-anthropomorphic abdomen phantom was imaged on these DECT systems. Scans were repeated three times for CTDIvol levels of 10 mGy, 20 mGy, 30 mGy and different fat-simulating extension rings. Over the available range of virtual-monoenergetic images (VMI), noise as well as quantitative accuracy of hounsfield units (HU) and iodine concentrations were evaluated. RESULTS: For all VMI levels, HU values could be determined with high accuracy compared to theoretical values. For KVSCT and DSCT, a noise increase was observed towards lower VMI levels. A patient-size dependent increase in the uncertainty of quantitative iodine concentrations is observed for all platforms. For a medium patient size the iodine concentration root-mean-square deviation at 20 mGy is 0.17 mg/ml (DLCT), 0.30 mg/ml (KVSCT) and 0.77mg/ml (DSCT). CONCLUSION: Noticeable performance differences are observed between investigated DECT systems. Iodine concentrations and VMI HUs are accurately determined across all DECT systems. KVSCT and DLCT deliver slightly more accurate iodine concentration values than DSCT for investigated scenarios. In DLCT, low-noise and high-image contrast at low VMI levels may help to increase diagnostic information in abdominal CT. KEY POINTS: • Current dual-energy CT platforms provide accurate, reliable quantitative information. • Dual-energy CT cross-platform evaluation revealed noticeable performance differences between different systems. • Dual-layer CT offers constant noise levels over the complete energy range.


Asunto(s)
Fantasmas de Imagen , Radiografía Abdominal/métodos , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Tomografía Computarizada por Rayos X/métodos , Abdomen/diagnóstico por imagen , Antropometría/métodos , Diseño de Equipo , Humanos , Yodo
15.
Acta Radiol ; 59(10): 1225-1231, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-29320863

RESUMEN

Background The explosive growth of computer tomography (CT) has led to a growing public health concern about patient and population radiation dose. A recently introduced technique for dose reduction, which can be combined with tube-current modulation, over-beam reduction, and organ-specific dose reduction, is iterative reconstruction (IR). Purpose To evaluate the quality, at different radiation dose levels, of three reconstruction algorithms for diagnostics of patients with proven liver metastases under tumor follow-up. Material and Methods A total of 40 thorax-abdomen-pelvis CT examinations acquired from 20 patients in a tumor follow-up were included. All patients were imaged using the standard-dose and a specific low-dose CT protocol. Reconstructed slices were generated by using three different reconstruction algorithms: a classical filtered back projection (FBP); a first-generation iterative noise-reduction algorithm (iDose4); and a next generation model-based IR algorithm (IMR). Results The overall detection of liver lesions tended to be higher with the IMR algorithm than with FBP or iDose4. The IMR dataset at standard dose yielded the highest overall detectability, while the low-dose FBP dataset showed the lowest detectability. For the low-dose protocols, a significantly improved detectability of the liver lesion can be reported compared to FBP or iDose4 ( P = 0.01). The radiation dose decreased by an approximate factor of 5 between the standard-dose and the low-dose protocol. Conclusion The latest generation of IR algorithms significantly improved the diagnostic image quality and provided virtually noise-free images for ultra-low-dose CT imaging.


Asunto(s)
Algoritmos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/patología , Metástasis de la Neoplasia/diagnóstico por imagen , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Estudios Prospectivos
16.
J Appl Clin Med Phys ; 19(1): 204-217, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-29266724

RESUMEN

The performance of a recently introduced spectral computed tomography system based on a dual-layer detector has been investigated. A semi-anthropomorphic abdomen phantom for CT performance evaluation was imaged on the dual-layer spectral CT at different radiation exposure levels (CTDIvol of 10 mGy, 20 mGy and 30 mGy). The phantom was equipped with specific low-contrast and tissue-equivalent inserts including water-, adipose-, muscle-, liver-, bone-like materials and a variation in iodine concentrations. Additionally, the phantom size was varied using different extension rings to simulate different patient sizes. Contrast-to-noise (CNR) ratio over the range of available virtual mono-energetic images (VMI) and the quantitative accuracy of VMI Hounsfield Units (HU), effective-Z maps and iodine concentrations have been evaluated. Central and peripheral locations in the field-of-view have been examined. For all evaluated imaging tasks the results are within the calculated theoretical range of the tissue-equivalent inserts. Especially at low energies, the CNR in VMIs could be boosted by up to 330% with respect to conventional images using iDose/spectral reconstructions at level 0. The mean bias found in effective-Z maps and iodine concentrations averaged over all exposure levels and phantom sizes was 1.9% (eff. Z) and 3.4% (iodine). Only small variations were observed with increasing phantom size (+3%) while the bias was nearly independent of the exposure level (±0.2%). Therefore, dual-layer detector based CT offers high quantitative accuracy of spectral images over the complete field-of-view without any compromise in radiation dose or diagnostic image quality.


Asunto(s)
Fantasmas de Imagen , Garantía de la Calidad de Atención de Salud/normas , Protección Radiológica/métodos , Imagen Radiográfica por Emisión de Doble Fotón/instrumentación , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Tomografía Computarizada por Rayos X/métodos , Imagen de Cuerpo Entero/métodos , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Dosis de Radiación , Protección Radiológica/instrumentación , Tomografía Computarizada por Rayos X/instrumentación
17.
Radiology ; 283(3): 723-728, 2017 06.
Artículo en Inglés | MEDLINE | ID: mdl-27918709

RESUMEN

Purpose To investigate the feasibility of using spectral photon-counting computed tomography (CT) to differentiate between gadolinium-based and nonionic iodine-based contrast material in a colon phantom by using the characteristic k edge of gadolinium. Materials and Methods A custom-made colon phantom was filled with nonionic iodine-based contrast material, and a gadolinium-filled capsule representing a contrast material-enhanced polyp was positioned on the colon wall. The colon phantom was scanned with a preclinical spectral photon-counting CT system to obtain spectral and conventional data. By fully using the multibin spectral information, material decomposition was performed to generate iodine and gadolinium maps. Quantitative measurements were performed within the lumen and polyp to quantitatively determine the absolute content of iodine and gadolinium. Results In a conventional CT section, absorption values of both contrast agents were similar at approximately 110 HU. Contrast material maps clearly differentiated the distributions, with gadolinium solely in the polyp and iodine in the lumen of the colon. Quantitative measurements of contrast material concentrations in the colon and polyp matched well with those of actual prepared mixtures. Conclusion Dual-contrast spectral photon-counting CT colonography with iodine-filled lumen and gadolinium-tagged polyps may enable ready differentiation between polyps and tagged fecal material. © RSNA, 2016.


Asunto(s)
Colonografía Tomográfica Computarizada , Colonografía Tomográfica Computarizada/métodos , Medios de Contraste , Gadolinio , Compuestos de Yodo , Fantasmas de Imagen , Fotones
18.
Abdom Imaging ; 40(5): 1213-22, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25348732

RESUMEN

PURPOSE: Aim of our study was to compare the diagnostic performance of (18)F-FDG PET/CT and MR imaging (MRI) in the detection of liver metastases in patients with adenocarcinomas of the gastrointestinal tract. METHODS: A total of 49 patients with adenocarcinomas of the gastrointestinal tract who had undergone (18)F-FDG PET/CT and MRI of the liver were included in this study. The MRI protocol included diffusion-weighted imaging and dynamic contrast-enhanced MR imaging after intravenous injection of Gd-DTPA. PET and MR images were analyzed by two experienced radiologists. Imaging results were correlated with histopathological findings or imaging follow-up as available. Sensitivities of both modalities were compared using McNemar Test. Receiver operating characteristic (ROC) curves were calculated to determine the diagnostic performance in correctly identifying liver metastases. RESULTS: A total of 151 metastases were confirmed. For lesion detection, MRI was significantly superior to (18)F-FDG PET/CT. Sensitivity of MRI in detecting metastases was 86.8% for Reader 1 (R1) and 87.4% for Reader 2 (R2), of PET/CT 66.2% for R1 and 68.2% for R2. Regarding only metastases with diameters of 10 mm or less, sensitivities of MRI were 66.7% for R1 and 75.0% for R2, and were significantly higher than those of PET/CT (17.9% for R1 and 20.5% for R2). ROC analysis showed superiority for lesion classification of MRI as compared to (18)F-FDG PET/CT. CONCLUSION: MRI is significantly superior to (18)F-FDG PET/CT in the detection and classification of liver metastases in patients with adenocarcinomas of the gastrointestinal tract, especially in the detection of small metastases.


Asunto(s)
Adenocarcinoma/diagnóstico , Neoplasias Gastrointestinales/patología , Neoplasias Hepáticas/diagnóstico , Imagen por Resonancia Magnética , Tomografía de Emisión de Positrones , Tomografía Computarizada por Rayos X , Adenocarcinoma/secundario , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Fluorodesoxiglucosa F18 , Humanos , Neoplasias Hepáticas/secundario , Masculino , Persona de Mediana Edad , Radiofármacos , Estudios Retrospectivos
19.
Radiology ; 272(3): 739-48, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-24814175

RESUMEN

PURPOSE: To determine if grating-based x-ray phase-contrast computed tomography (CT) can allow differentiation of simulated simple, protein-rich, hemorrhagic, and enhancing cystic renal lesions in an in vitro phantom. MATERIALS AND METHODS: An in vitro phantom specifically designed to simulate simple, protein-rich, hemorrhagic, and enhancing renal cysts was scanned with an experimental grating-based phase-contrast CT setup consisting of a Talbot-Lau interferometer with a rotating anode x-ray tube and a single photon counting detector. Various combinations of serum and saline (100% and 0% to 0% and 100%), blood and saline, blood and serum (100% and 0% to 6.25% and 93.75% for both), and an iodinated contrast agent and saline (7.6-1.6 mg per milliliter of saline) were used to reproduce the chemical composition of the different types of cysts. A thickened solution of an iodinated contrast agent calibrated with a clinical multidetector CT scanner served as contrast agent-enhanced renal parenchyma (195 HU at 80 kVp, 400 mAs and 98 HU at 140 kVp, 200 mAs). Standard attenuation- and phase-contrast images were reconstructed from the raw projection data. Quantitative values for attenuation and phase contrast and image noise were determined. Contrast-to-noise ratios were calculated. Simulated lesions were assessed for visual differentiability by means of pairwise comparison of the attenuation- and phase-contrast images and both images simultaneously. RESULTS: Attenuation-contrast imaging showed large differences in Hounsfield units with increasing concentrations of iodine (118.9 HU for 1.6 mg/mL vs 331.4 HU for 7.6 mg/mL). Values for phase-contrast imaging were substantially distinguishable for saline, serum, and blood (7.9, 23.7, and 52.8 HU, respectively). Both imaging modalities combined allowed differentiation of all four types of simulated cysts (100% saline, 100% serum, 100% blood, and 1.6-7.6 mg of iodine per milliliter of saline) with one imaging acquisition. CONCLUSION: Grating-based phase-contrast CT allows differentiation of simulated simple, protein-rich, hemorrhagic, and enhancing renal cysts in an in vitro phantom through simultaneous assessment of their distinct attenuation- and phase-contrast signal.


Asunto(s)
Enfermedades Renales Quísticas/diagnóstico por imagen , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Difracción de Rayos X/métodos , Humanos , Fantasmas de Imagen , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X/instrumentación , Difracción de Rayos X/instrumentación
20.
Eur Radiol ; 24(1): 250-5, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23996016

RESUMEN

OBJECTIVE: To improve the detection of liver lesions in patients with hepatocellular carcinoma (HCC) via an iodine contrast enhancement tool. METHODS: Thirty-two patients with clinically proven HCCs underwent imaging with a three-phase protocol on a 256-slice MDCT. The contrast enhancement in the reconstructed slices was improved via a post-processing tool. Mean image noise was measured in four different regions: liver lesion, healthy liver, subcutaneous fat and bone. For each image set the image noise and contrast-to-noise ratio (CNR) were assessed. For subjective image assessment, four experienced radiologists evaluated the diagnostic quality. RESULTS: While employing the post-processing algorithm, CNR between the liver lesion and healthy liver tissue improves significantly by a factor of 1.78 (CNRwithout vC = 2.30 ± 1.92/CNRwith vC = 4.11 ± 3.05) (P* = 0.01). All results could be achieved without a strengthening of artefacts; mean HU values of subcutaneous fat and bone did not significantly change. Subjective image analysis illustrated a significant improvement when employing post-processing for clinically relevant criteria such as diagnostic confidence. CONCLUSION: With post-processing we see a significantly improved detection of arterial uptake in hepatic lesions compared with non-processed data. The improvement in CNR was confirmed by subjective image assessment for small lesions and for lesions with limited uptake. KEY POINTS: • Enhancement with iodine-based contrast agents is an essential part of CT. • A new post-processing tool significantly improves the diagnostics of hepatocellular carcinoma. • It also improves detection of small lesions with limited iodine uptake.


Asunto(s)
Algoritmos , Carcinoma Hepatocelular/diagnóstico por imagen , Neoplasias Hepáticas/diagnóstico por imagen , Tomografía Computarizada Multidetector/métodos , Interpretación de Imagen Radiográfica Asistida por Computador , Adulto , Anciano , Anciano de 80 o más Años , Artefactos , Medios de Contraste , Diagnóstico Diferencial , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA