Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Environ Sci Technol ; 46(2): 1035-43, 2012 Jan 17.
Artículo en Inglés | MEDLINE | ID: mdl-22136630

RESUMEN

Five activated carbons (ACs) and two biochars were tested as amendments to reduce the availability of aged polychlorinated dibenzo-p-dioxin/dibenzofurans (PCDD/Fs) in two soils. All sorbents (ACs and biochars) tested substantially reduced the availability of PCDD/Fs measured by polyoxymethylene (POM) passive uptake and earthworm (E. fetida) biouptake. Seven sorbents amended at a level of 0.2 × soil total organic carbon (0.2X) reduced the passive uptake (physicochemical availability) of total PCDD/Fs in POM by 40% to 92% (or toxic equivalent by 48% to 99%). Sorbents with finer particle sizes or more macropores showed higher reduction efficiencies. The powdered regenerated AC and powdered coconut AC demonstrated to be the most effective and the two biochars also performed reasonably well especially in the powdered form. The passive uptake of PCDD/F in POM increased approximately 4 to 5 fold as the contact time between POM and soil slurry increased from 24 to 120 d while the efficacy of ACs in reducing the physicochemical availability remained unchanged. The reduction efficiencies measured by POM passive uptake for the regenerated AC were comparable to those measured by earthworm biouptake (bioavailability) at both dose levels of 0.2X and 0.5X. The biota-soil accumulation factor (BSAF) values for unamended soil ranged from 0.1 for tetra-CDD/F to 0.02 for octa-CDD/F. At both dose levels, the regenerated AC reduced the BSAFs to below 0.03 with the exception of two hexa-CDD/Fs. The reduction efficiencies measured by earthworm for coconut AC and corn stover biochar were generally less than those measured by POM probably due to larger particle sizes of these sorbents that could not be ingested by the worms.


Asunto(s)
Benzofuranos/química , Carbono/química , Carbón Orgánico/química , Dibenzodioxinas Policloradas/análogos & derivados , Suelo/química , Adsorción , Dibenzofuranos Policlorados , Restauración y Remediación Ambiental , Dibenzodioxinas Policloradas/química , Contaminantes del Suelo/química
2.
J Chromatogr A ; 1139(2): 285-300, 2007 Jan 19.
Artículo en Inglés | MEDLINE | ID: mdl-17157304

RESUMEN

The applicability of 13 different GC columns (Agilent HP-5MS, Restek Rtx-5MS, Rtx-Dioxin2, Supelco Equity 5, SP-2331, Varian VF-5MS, CP-Sil 8 CB LowBleed/MS, J&W Scientific DB-5, DB-225, DB-XLB, DB-5MS, Phenomenex ZB-5MS, and ZB-5UMS) for US Environmental Protection Agency (EPA) methods 1613b, 8290 and European Standard Method EN 1948 for measurement of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) has been evaluated for the separation of all International Toxic Equivalent Factor (I-TEF) isomers (tetra- through octachlorinated at 2,3,7,8 positions) from closely eluting isomers using high-resolution gas chromatography/high-resolution mass spectrometry (HRGC/HRMS). The relative performance data are compared based on mass chromatograms using a "visualization approach", absolute retention times, 2,3,7,8-substituted, total dioxins and furans concentrations, as well as TEQ comparisons. None of the columns tested were able to separate all 17 I-TEFs from other co-eluted isomers. Our data indicate that all I-TEFs isomers can be fully differentiated from closely eluting isomers using either of two sets of non-polar and polar stationary phase combinations. One set consists of DB-5 (HP-5MS, Rtx-5MS, Equity-5) and DB-225 GC columns and another set would have a combination of DB-5MS (ZB-5MS, VF-5MS, CP-Sil 8 CB LowBleed/MS) with SP-2331. However, depending on the source of PCDDs/PCDFs a laboratory could choose a single GC column that separates the 2,3,7,8-substituted congeners that contribute most significantly to the overall TEQ. These data are the most comprehensive to date, provide a valuable addition to operational criteria for the standard EPA methods 1613b, 8290, European Standard Method EN 1948 and will allow researches to compare data generated according to the different compliance analytical procedures.


Asunto(s)
Benzofuranos/aislamiento & purificación , Cromatografía de Gases/métodos , Dioxinas/aislamiento & purificación , Espectrometría de Masas/métodos , Dibenzodioxinas Policloradas/análogos & derivados , Dibenzodioxinas Policloradas/aislamiento & purificación
3.
J Chromatogr A ; 1057(1-2): 151-61, 2004 Nov 19.
Artículo en Inglés | MEDLINE | ID: mdl-15584234

RESUMEN

An extended study of seven fused silica capillary gas chromatographic (GC) columns has been conducted with regard to separation of international toxic equivalent factor (I-TEF) isomers (tetra- through octa-chlorinated at 2,3,7,8 positions) of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDDs/PCDFs) from closely co-eluted other isomers using high-resolution gas chromatography-high-resolution mass spectrometry (HRGC-HRMS). The data are explicated in mass chromatograms of Series 5 GC columns from a variety of manufacturers (Varian CP-Sil 8 CB LowBleed/MS, Phenomenex ZB-5UMS, Agilent HP-5MS, Restek Rtx-5MS, Supelco Equity-5, J&W Scientific DB-5 and DB-5MS), according to relative retention times, and 2,3,7,8-substituted isomer concentrations for each of the columns tested. Results showed differences between 5% phenyl methyl silicone and 5% silphenylene (Si-arylene) silicone polymer type GC stationary phases in separation of 2,3,7,8-substituted PCDDs/PCDFs from closely co-eluted isomers. The separation differences for Si-arylene type columns resulted in lower toxic equivalence (TEQ) values compared to the siloxane-based columns. Because of differences in product nomenclature and manufacturing practices by various manufacturers, incorrect assumptions and comparisons may be made regarding the interchangeability of these columns for PCCD/PCDF separations. The data presented are the most comprehensive to date and provide a valuable addition to operational criteria for the standard US Environmental Protection Agency methods 1613b and 8290.


Asunto(s)
Benzofuranos/aislamiento & purificación , Cromatografía de Gases/instrumentación , Dioxinas/aislamiento & purificación , Espectrometría de Masas/métodos , Sensibilidad y Especificidad
4.
Chemosphere ; 84(7): 913-22, 2011 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-21737113

RESUMEN

The applicability of three different Silphenylene Silicone co-polymer (Si-Arylene) GC stationary phases (J&W Scientific DB-5ms, Varian VF-5ms, and VF-Xms) has been evaluated for the separation of all 136 tetra- through the octa- chlorinated dibenzo-p-dioxins (PCDD) and chlorinated dibenzofurans (PCDF) from closely eluting isomers using gas chromatography/high resolution mass spectrometry (GC/HRMS). Their relative performance data are compared to the "conventional" 5% diphenyl 95% dimethylpolysiloxane GC column (Supelco Equity-5) and to each other based on absolute retention times, visualized mass chromatograms, and the separation of 2,3,7,8-substituted isomers. VF-Xms GC column was able to demonstrate a better performance towards separation of 2,3,7,8-substituted PCDD/PCDF compared to other Si-Arylene GC columns tested, where only 2,3,4,7,8-PnCDF can not be resolved from 1,2,3,6,9-PnCDF and 2,3,4,6,7,8-/1,2,3,6,8,9-HxCDF and 1,2,3,7,8,9-/1,2,3,4,8,9-HxCDF can be at least partially resolved. These data suggest that the development of a single GC column for the separation of all 17 2,3,7,8-substituted dioxins and furans is feasible, which therefore could be used as a standard tool for the PCDD/PCDF methods globally including USEPA methods 1613b, 8290A, 8280B, European Standard Method EN 1948, Canadian methods DFPCB-E3418, EPS 1/RM/19, Japanese methods JIS K0311 and JIS K0312. Having one specific GC column to separate all 2,3,7,8-substituted PCDD/PCDF will significantly improve the data quality, comparability by the various methods and assessment techniques while simultaneously leading to a more cost and time efficient operation.


Asunto(s)
Benzofuranos/química , Contaminantes Ambientales/química , Dibenzodioxinas Policloradas/análogos & derivados , Benzofuranos/análisis , Cromatografía de Gases/métodos , Dibenzofuranos Policlorados , Contaminantes Ambientales/análisis , Dibenzodioxinas Policloradas/análisis , Dibenzodioxinas Policloradas/química , Silicio/química , Siloxanos/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA