Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Arch Orthop Trauma Surg ; 142(7): 1367-1374, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33484311

RESUMEN

OBJECTIVES: The purpose of the study was to compare treatment outcomes after short or long cephalomedullary nailing for intertrochanteric femur fractures. DATA SOURCES: A systematic review of perioperative outcomes after short or long cephalomedullary nailing for intertrochanteric femur fractures was performed. The following databases were used: using the Cochrane Database of Systematic Reviews, the Cochrane Central Register of Controlled Trials, PubMed (1980-2019), and MEDLINE (1980-2019). The queries were performed in June 2019. STUDY SELECTION: The following search term query was used: "Intramedullary Nail AND Intertrochanteric Fracture OR "Long OR Short Nail AND intertrochanteric Fracture." Studies were excluded if they were "single-arm" studies (i.e., reporting on either long or short CMN but not both), or did not report at least one of the outcomes being meta-analyzed. Furthermore, cadaveric studies, animal studies, basic science articles, editorial articles, surveys and studies were excluded. DATA EXTRACTION: Two investigators independently reviewed abstracts from all identified articles. Full-text articles were obtained for review if necessary, to allow further assessment of inclusion and exclusion criteria. Additionally, all references from the included studies were reviewed and reconciled to verify that no relevant articles were missing from the systematic review. DATA SYNTHESIS: Short nails were associated with statistically significantly less estimated blood loss and operative time compared to long nails. There were no significant differences in transfusion rates, implant failures or overall re-operation rates between implant lengths. Similarly, there was no significant difference in peri-implant fracture between implant lengths. CONCLUSIONS: Overall, the available clinical evidence supports the use of short cephalomedullary nails for the majority of intertrochanteric femur fractures. STUDY DESIGN/LEVEL OF EVIDENCE: Meta-analysis; Level III, therapeutic.


Asunto(s)
Fijación Intramedular de Fracturas , Fracturas de Cadera , Fracturas Periprotésicas , Clavos Ortopédicos , Fracturas de Cadera/cirugía , Humanos , Estudios Retrospectivos , Revisiones Sistemáticas como Asunto , Resultado del Tratamiento
2.
Eur J Orthop Surg Traumatol ; 31(1): 65-70, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-32710126

RESUMEN

PURPOSE: The optimal management of valgus-impacted femoral neck fractures remains controversial. Internal fixation is associated with significant rates of re-operation, while historical non-operative management strategies consisting of prolonged bed rest also resulted in patient morbidity. Our hypothesis was that screw fixation would have comparable failure rates to non-operative treatment and immediate mobilization for valgus-impacted femoral neck fractures. METHODS: Retrospective cohort at a single academic Level I trauma center of patients with valgus-impacted femoral neck fractures (AO/OTA 31-B1) treated with percutaneous screw fixation (n = 97) or non-operatively (n = 28). Operative treatment consisted of percutaneous screw fixation. Non-operative treatment consisted of early mobilization. The primary outcome was a salvage operation. Patient demographics were assessed between groups. RESULTS: More non-operatively treated patients were permitted unrestricted weight-bearing (WBAT; p = 0.002). There was no increase in complication rates or mortality, and return to previous ambulatory status was comparable between operatively and non-operatively treated patients. 35.7% (10/28) of non-operatively treated patients underwent a subsequent operation, compared to 15.5% (15/97) of patients with screw fixation (p = 0.03). Only WBAT was independently associated with treatment failure (OR 3.1, 95%CI 1.2-8.3, p =0.02). WBAT was predictive of treatment failure only in the non-operatively treated group (64.3%, 9/14 WBAT vs 8.3%, 1/12 partial, p =0.005). CONCLUSION: After controlling for weight-bearing restrictions, we found no difference in failure rates between non-operative treatment and screw fixation. Non-operative treatment with partial weight-bearing had low failure rates, comparable complication and mortality rates, and equivalent functional outcomes to operative treatment and is reasonable if a patient would like to avoid surgery and accepts the risk of subsequent arthroplasty. Overall, there were relatively high failure rates in all groups.


Asunto(s)
Tratamiento Conservador , Fracturas del Cuello Femoral , Fijación Interna de Fracturas , Adulto , Anciano , Anciano de 80 o más Años , Tornillos Óseos , Femenino , Fracturas del Cuello Femoral/cirugía , Fracturas del Cuello Femoral/terapia , Fijación Interna de Fracturas/efectos adversos , Fijación Interna de Fracturas/instrumentación , Fijación Interna de Fracturas/métodos , Humanos , Masculino , Persona de Mediana Edad , Reoperación , Estudios Retrospectivos , Resultado del Tratamiento , Soporte de Peso
3.
Orthop J Sports Med ; 11(10): 23259671231200805, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37822419

RESUMEN

Background: Developmental dysplasia of the hip (DDH) and trochlear dysplasia (TD) are distinct pathologies with several important features in common. In addition to shared risk factors, both forms of dysplasia cause abnormal joint kinematics and force transmission, predisposing patients to pain, injuries to cartilage and soft tissue stabilizers, and ultimately arthritis. Purpose: To evaluate for an association between hip dysplasia and TD in skeletally mature patients with symptomatic hip dysplasia. Study Design: Cross-sectional study; Level of evidence, 3. Methods: A total of 48 patients with DDH who underwent periacetabular osteotomy were compared with 48 sex-matched patients who underwent hip arthroscopy for femoroacetabular impingement (FAI) between July 2014 and February 2021. All patients were skeletally mature. The Tönnis angle and lateral center-edge angle were measured on preoperative pelvis radiographs. Femoral version, trochlear depth, lateral trochlear inclination (LTI), tibial tubercle-trochlear groove distance (TTTG-d), and posterior lateral condylar angle (PLCA) were measured on preoperative magnetic resonance imaging scans of the symptomatic hip and ipsilateral knee. Continuous variables were compared between the patient groups using 2-sample t tests. Interobserver reliability was measured using the intraclass correlation coefficient. Results: Patients with DDH demonstrated a reduced trochlear depth compared with patients with FAI (3.6 vs 4.6 mm; P < .001). There were no differences between groups in femoral anteversion, LTI, TTTG-d, or PLCA. Two (4.2%) patients with FAI and 17 (35.4%) patients with DDH had a trochlear depth <3 mm (P < .001). One (2.1%) patient with FAI and 7 (14.6%) patients with DDH had an LTI <11° (P = .027). There was no difference between groups in frequency of a convex proximal trochlea, patient-reported ipsilateral knee pain, or ipsilateral knee procedures. Conclusion: Patients with DDH had reduced trochlear depth compared with patients with FAI, demonstrating a higher incidence of dysplastic trochlear features that may predispose patients to patellofemoral joint disease. Further research is needed to determine whether screening at-risk patients and treating TD will help to prevent symptomatic patellofemoral disease.

4.
J Am Acad Orthop Surg ; 31(5): 239-244, 2023 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-36728274

RESUMEN

OBJECTIVE: To report the current state of institutional protocols regarding the use of MRI in patients with external fixation devices (EFDs) in the United States. DESIGN: National Survey Study. PARTICIPANTS: Practicing orthopaedic surgeons frequenting the Orthopaedic Trauma Association website were invited to participate in this study. RESULTS: Sixty-two eligible orthopaedic surgeons completed the survey. No respondents reported any known harmful complications of MRI use with an EFD. Eight respondents (13%) reported at least one early scan termination because of mild warmth or vibration without any lasting complications. Fifty-six respondents (90%) reported delays to care related to MRI-EFD compatibility labeling, and 27 respondents (48%) reported delayed MRI scans in every patient with an EFD who needed one. Twenty-six surgeons (42%) had modified their practice in some way in response to these barriers. Examples include delaying EFD placement until after MRI, relying on CT arthrograms over MRI for surgical planning, and taking patients to the operating room to remove EFDs temporarily and then replace them. Nineteen respondents (31%) had developed formal protocols to address this issue, but having a written protocol was not associated with any decrease in delays ( P = 0.119). Eighty-nine percent of respondents thought there was a need for a national consensus guideline on this issue. CONCLUSION: Despite no previous reports of harmful complications, MRI utilization is frequently delayed or prevented in patients with EFDs in place. This is a pervasive problem nationally, which persists despite the implementation of written institutional protocols. Additional research is needed, potentially at the national level, to address this common issue. LEVEL OF EVIDENCE: V.


Asunto(s)
Fijadores Externos , Imagen por Resonancia Magnética , Humanos , Estados Unidos , Encuestas y Cuestionarios
5.
Dement Geriatr Cogn Disord ; 33(4): 219-25, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22584618

RESUMEN

BACKGROUND: Convergent evidence suggests that oxidative stress plays a central role in the pathology of Alzheimer's disease (AD). We asked if consequently, oxidation of methionine residues to methionine sulfoxide (MetO) was increased in plasma proteins of persons carrying familial AD (FAD) mutations. METHODS: Plasma was collected from 31 persons from families harboring PSEN1 or APP mutations. Using Western blot analysis with a novel anti-MetO polyclonal antibody, MetO levels were measured and compared between FAD mutation carriers (MCs) and non-mutation carrying (NCs) kin. RESULTS: A MetO-positive 120-kDa gel band distinguished FAD MCs and NCs (mean 11.4 ± 2.8 vs. 4.0 ± 3.1, p = 0.02). In a subset of subjects for whom both measurements were available, MetO levels correlated well with plasma F2-isoprostane (r = 0.81, p < 0.001) and superoxide dismutase 1 (r = 0.52, p = 0.004) levels. CONCLUSION: Our data provide evidence for elevated MetO levels in persons carrying FAD mutations that correlate with other indices of oxidative stress and suggest that plasma oxidative stress markers may be useful for diagnosis of AD.


Asunto(s)
Enfermedad de Alzheimer/sangre , Enfermedad de Alzheimer/genética , Metionina/análogos & derivados , Adulto , Precursor de Proteína beta-Amiloide/genética , Análisis de Varianza , Apolipoproteínas E/genética , Proteínas Sanguíneas/genética , Western Blotting , ADN/genética , Femenino , Genotipo , Humanos , Isoprostanos/sangre , Masculino , Metionina/sangre , Mutación/genética , Mutación/fisiología , Estrés Oxidativo/fisiología , Presenilina-1/genética , Superóxido Dismutasa/genética , Superóxido Dismutasa-1
6.
Injury ; 53(2): 752-755, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34654551

RESUMEN

OBJECTIVE: To determine the accuracy of International Classification of Disease Version 10 (ICD-10) coding for ankle fracture injury patterns. DESIGN: Retrospective cohort study PATIENTS: 97 adult patients with fractures about the ankle (rotational ankle fracture or distal tibia fracture) from 2016 to 2020, selected by stratified random sampling. INTERVENTION: Assignment of an ICD-10 code representative of a rotational ankle fracture, pilon fracture, or unspecified fracture of the lower leg. OUTCOME MEASUREMENTS: Injury radiographs were reviewed by three authors to determine the correct code. Agreement between the correct code and the electronic medical record (EMR) assigned code was determined using kappa's statistic in the aggregate as well as percent agreement, sensitivity, specificity, and positive predictive value (PPV) between individual codes. RESULTS: 59 of 97 cases (60.8%) demonstrated discordance between the existing EMR and surgeon-assigned codes. Aggregate agreement between all codes was fair (K = 0.26). Lateral malleolus fracture codes demonstrated the highest PPV (0.91, 95% CI 0.72-0.99), while the lowest PPV was found for "other fractures of the lower leg" (0.05, 95% CI 0.0-0.24) and "other fracture of the fibula" (0.0, 95% CI 0.0-0.15). Generalized "other fracture" codes comprised 45% of EMR codes compared to only 6% of assigned codes (p < 0.001). EMR codes were specific but not sensitive. CONCLUSION: There is substantial discordance between existing EMR and surgeon-assigned ICD-10 codes for ankle fractures. Database research that relies on ICD-10 coding as a surrogate for primary clinical data should be interpreted with caution and institutions should make efforts to increase the accuracy of their coding.


Asunto(s)
Fracturas de Tobillo , Adulto , Fracturas de Tobillo/diagnóstico por imagen , Bases de Datos Factuales , Humanos , Clasificación Internacional de Enfermedades , Reproducibilidad de los Resultados , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA