Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 74
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Echocardiography ; 41(1): e15698, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38284664

RESUMEN

BACKGROUND: Transaortic valve implant (TAVI) is the treatment of choice for severe aortic stenosis (AS). Some patients develop prosthesis patient mismatch (PPM) after TAVI. It is challenging to determine which patients are at risk for clinical deterioration. METHODS: We retrospectively measured echocardiographic parameters of left ventricular (LV) morphology and function, prosthetic aortic valve effective orifice area (iEOA) and hemodynamics in 313 patients before and 1 year after TAVI. Our objective was to compare the change in echocardiographic parameters associated with left ventricular reverse modeling in subjects with and without PPM. Our secondary objective was to evaluate echo parameters associated with PPM and the relationship to patient functional status and survival post-TAVI. RESULTS: We found that 82 (26.2%) of subjects had moderate and 37 (11.8%) had severe PPM post-TAVI. There was less relative improvement in LVEF with PPM (1.9 ± 21.3% vs. 8.2 + 30.1%, p = .045). LV GLS also exhibited less relative improvement in those with PPM (13.4 + 34.1% vs. 30.9 + 73.3%, p = .012). NYHA functional class improved in 84.3% of subjects by one grade or more. Echocardiographic markers of PPM were worse in those without improvement in NYHA class (mean AT/ET was .29 vs. .27, p = .05; DVI was .46 vs. .51, p = .021; and iEOA was .8 cm/m2 vs. .9 cm/m2 , p = .025). There was no association with PPM and survival. CONCLUSIONS: There was no improvement in LVEF and less improvement in LV GLS in those with PPM post-TAVI. Echocardiographic markers of PPM were present in those with lack of improvement in NYHA functional class.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estudios Retrospectivos , Remodelación Ventricular , Resultado del Tratamiento , Ecocardiografía
2.
J Card Surg ; 36(1): 89-96, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33170533

RESUMEN

OBJECTIVE: Surgical reoperation for aortic homograft structural valve degeneration (SVD) is a high-risk procedure. Transcatheter aortic valve replacement (TAVR) for homograft-SVD is an alternative to reoperation, but descriptions of implantation techniques are limited. This study compares outcome in patients undergoing into two groups by the type of previously implanted aortic valve prosthesis: TAVR for failed aortic homografts (TAVR-H) or for stented aortic bioprostheses (TAVR-BP). METHODS: From 2015 to 2017, TAVR was performed in 41 patients with SVD. Thirty-three patients in the TAVR-BP group (six for SVD of valved conduits), and eight patients in the TAVR-H group. The Valve Academic Research Consortium criteria were used for outcome reporting purposes. RESULTS: The patients with TAVR-BP had predominant prosthetic stenosis (94%, p = .002), whereas TAVR-H individuals presented mostly with regurgitation (88%, p = <.001). Patients with TAVR-H received: Sapien-3 (6), Sapien-XT (1), and CoreValve (1) devices. Low, 40% ventricular fixation in relation to homograft annulus was attempted to anchor the prosthesis on the homograft suture-line. One patient with TAVR-BP experienced intraoperative distal prosthesis migration and Type-B aortic dissection, and two patients in the TAVR-H group had late postoperative proximal device migration. In both groups, there was zero 30-day mortality, stroke, or pacemaker implantation. CONCLUSIONS: TAVR for failing aortic homografts may be a feasible and safe alternative to high-risk surgical reintervention. Precise, 40%-ventricular device positioning appears crucial for prevention of late paravalvular leak/late prosthesis migration and minimizing the risk of repeat surgical intervention.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Aloinjertos , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Humanos , Diseño de Prótesis , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
3.
Echocardiography ; 37(6): 913-916, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32472553

RESUMEN

Tricuspid valve (TV) degeneration after surgical repair with an annuloplasty ring is problematic as redo operation carries high mortality. This can be addressed with transcatheter therapies to implant a valve within in prior ring (tricuspid valve-in-ring). When an incomplete ring is present, paravalvular leak is commonly encountered after tricuspid valve-in-ring (TViR) implant; however, this can be addressed with paravalvular leak closure devices. Multimodality imaging including cardiac computed tomography and three-dimensional (3D) transesophageal echocardiography (TEE) are important for successful TViR implant. We report a case of tricuspid regurgitation after tricuspid repair with an incomplete annuloplasty ring and subsequent paravalvular leak closure.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Tricúspide , Cateterismo Cardíaco , Ecocardiografía Transesofágica , Prótesis Valvulares Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Válvula Mitral/cirugía , Resultado del Tratamiento , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/cirugía
4.
Pacing Clin Electrophysiol ; 42(2): 146-152, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30548869

RESUMEN

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is increasingly used to treat severe aortic stenosis. A frequent complication of TAVR is high-grade or complete atrioventricular (AV) block requiring a permanent pacemaker (PPM). There are little data on the long-term dependency on pacing after TAVR. The objective of this study was to determine the proportion of patients receiving a PPM for high-grade or complete AV block after TAVR who remain dependent on the PPM in follow-up and to determine any risk factors for, particularly the effect of postballoon dilation (PBD) on, pacemaker dependency. METHODS: Of 594 consecutive patients without prior PPM undergoing TAVR (81.9% balloon-expandable, 18.1% self-expandable valve), 67 (13.1%) received a PPM after TAVR. PPM dependency was defined as AV block with a ventricular escape rate of ≤ 40 beats/min. Patient and procedural characteristics were examined according to PPM dependency status. RESULTS: Of the 67 patients who received a PPM within 10 days after TAVR, 27/67 (40.3%) were dependent at first follow-up and only 9/41 (21.9%) at 1 year. PPM dependency was more common after a self-expanding valve (76.9% vs 31.5%, P < 0.01), in those who underwent PBD (66.7% vs 24.4%, P < 0.01), and in patients in persistent complete AV block at PPM implantation (62.5% vs 7.4%, P < 0.01). CONCLUSIONS: Fewer than half of patients who receive a new PPM following TAVR are pacemaker dependent at early follow-up (< 30 days). The use of self-expanding valves and PBD are associated with a markedly increased risk of PPM dependency.


Asunto(s)
Bloqueo Atrioventricular/etiología , Bloqueo Atrioventricular/terapia , Marcapaso Artificial , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/terapia , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano de 80 o más Años , Bloqueo Atrioventricular/fisiopatología , Femenino , Sistema de Conducción Cardíaco , Humanos , Masculino , Marcapaso Artificial/efectos adversos , Complicaciones Posoperatorias/fisiopatología , Recuperación de la Función , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo
5.
Catheter Cardiovasc Interv ; 89(5): 860-865, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-27468705

RESUMEN

OBJECTIVES: We studied the impact of operator experience on trans-radial (TR) cardiac catheterization performance in contemporary practice. BACKGROUND: TR cardiac catheterization offers advantages over trans-femoral (TF) cardiac catheterization, but the TR approach has been slowly adopted in the United States. METHODS: We reviewed all cases of attempted TR cardiac catheterization at a single tertiary care medical center from May 2008 until April 2015. We classified the attending operator TR case experience at the time of each case, and the control group constituted cases performed by operators with >300 TR cases. Study endpoints were TR cannulation failure, TF cross-over, contrast medium dose, and fluoroscopy time. RESULTS: Over the study period, 4177 attempted TR cardiac catheterization cases were performed. The percentage of TR cases performed with percutaneous coronary intervention (PCI) increased from 14.0% in 2009 to 30.2% in 2015 (P-trend <0.001). The rate of TR cannulation failure decreased from 4.3% in 2009 to 2.0% in 2015 (P-trend = 0.071), and the rate of TF cross-over decreased from 4.3% in 2009 to 3.2% in 2015 (P-trend = 0.034). Operators with over 100 cases had the lowest odds of TR cannulation failure, while operators with over 200 cases had the lowest odds of TF cross-over. Operators with over 200 cases used the lowest mean contrast medium dose and mean fluoroscopy time. CONCLUSIONS: Increasing operator TR experience is associated with lower odds of TR cannulation failure and TF cross-over, as well as lower contrast medium dose and fluoroscopy time. © 2016 Wiley Periodicals, Inc.


Asunto(s)
Cateterismo Cardíaco/métodos , Cardiología/educación , Competencia Clínica , Enfermedad de la Arteria Coronaria/diagnóstico , Educación Médica Continua/métodos , Intervención Coronaria Percutánea/educación , Enfermedad de la Arteria Coronaria/cirugía , Femenino , Estudios de Seguimiento , Humanos , Curva de Aprendizaje , Masculino , Persona de Mediana Edad , Arteria Radial , Estudios Retrospectivos , Factores de Tiempo
6.
Catheter Cardiovasc Interv ; 89(7): 1286-1291, 2017 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-27566989

RESUMEN

OBJECTIVES: We assessed whether post-operative delirium is associated with healthcare utilization and overall survival after trans-catheter aortic valve replacement. BACKGROUND: Delirium, a common syndrome among hospitalized older adults, is associated with increased morbidity and mortality. METHODS: We reviewed 294 transcatheter aortic valve replacement cases between June 2008 and February 2015 at a tertiary care academic medical center. Post-operative delirium was identified by confusion assessment method screening and clinician diagnosis. RESULTS: Delirium was identified in 61 patients (21%). Non-femoral access for trans-catheter aortic valve replacement was more common in delirious patients than in non-delirious patients (41% vs. 27%, P = 0.04). Delirious patients had diminished overall survival after trans-catheter aortic valve replacement compared to non-delirious patients (1-year survival 59% vs. 84%, log-rank P = 0.002). After adjusting for age, Society of Thoracic Surgeons predicted 30-day mortality, and access type; delirium remained independently associated with diminished overall survival (hazard ratio 2.01, 95% confidence interval 1.21-3.33, P = 0.007). The delirium group had longer mean hospital stay (13.3 ± 9.5 days vs. 6.7 ± 3.8 days, P < 0.001) and a higher rate of discharge to a rehabilitation facility (61% vs. 27%, P < 0.001), but there was no difference in 30-day hospital re-admission rates or 30-day mortality based on delirium status. CONCLUSIONS: Delirium occurs in one out of five patients after trans-catheter aortic valve replacement and is associated with diminished survival and increased healthcare utilization. Further studies are needed to clarify whether strategies aimed at reducing delirium after trans-catheter aortic valve replacement may improve outcomes in this high-risk subset. © 2016 Wiley Periodicals, Inc.


Asunto(s)
Delirio/terapia , Recursos en Salud/estadística & datos numéricos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano , Anciano de 80 o más Años , Delirio/diagnóstico , Delirio/etiología , Delirio/mortalidad , Femenino , Humanos , Tiempo de Internación , Masculino , Alta del Paciente , Modelos de Riesgos Proporcionales , Centros de Rehabilitación , Estudios Retrospectivos , Factores de Riesgo , Centros de Atención Terciaria , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
8.
Curr Atheroscler Rep ; 18(5): 27, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-27021619

RESUMEN

Severe aortic stenosis (AS) is a life-threatening condition when left untreated. Aortic valve replacement (AVR) is the gold standard treatment for the majority of patients; however, transcatheter aortic valve implantation/replacement (TAVI/TAVR) has emerged as the preferred treatment for high-risk or inoperable patients. The concept of transcatheter heart valves originated in the 1960s and has evolved into the current Edwards Sapien and Medtronic CoreValve platforms available for clinical use. Complications following TAVI, including cerebrovascular events, perivalvular regurgitation, vascular injury, and heart block have decreased with experience and evolving technology, such that ongoing trials studying TAVI in lower risk patients have become tenable. The multidisciplinary team involving the cardiac surgeon and cardiologist plays an essential role in patient selection, procedural conduct, and perioperative care.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Cateterismo Cardíaco , Humanos , Selección de Paciente , Complicaciones Posoperatorias
9.
Catheter Cardiovasc Interv ; 85(5): 828-31, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25381962

RESUMEN

We describe a case of a 75-year-old woman presenting emergently with an anterior S-T elevation myocardial infarction that deteriorated into ventricular fibrillation requiring prompt resuscitation, resulting in cardiogenic shock. Emergency primary percutaneous coronary intervention of the left anterior descending coronary artery with adjunctive abciximab and heparin resulted in adequate coronary flow, and intra-aortic balloon pump was used to support hemodynamics. Within one hour of intervention, she developed acute respiratory distress with four-quadrant opacification of lung fields, difficulty with oxygenation, and hypotension. Emergency bronchoscopy revealed diffuse erythematous proximal airways with bloody secretions bilaterally confirming diffuse alveolar hemorrhage. An emergency veno-arterial extracorporeal membranous oxygenation (ECMO) circuit was placed at the bedside, acutely improving oxygenation and hemodynamics. She survived the hospitalization with multiple complications related to access site and prolonged intensive care unit stay, was discharged to acute rehabilitation. She is currently thriving 18 months post-procedure. This case highlights the use of ECMO in the often-fatal condition of diffuse alveolar hemorrhage related to glycoprotein inhibitor use.


Asunto(s)
Anticuerpos Monoclonales/efectos adversos , Oxigenación por Membrana Extracorpórea/métodos , Hemoptisis/inducido químicamente , Técnicas Hemostáticas , Fragmentos Fab de Inmunoglobulinas/efectos adversos , Abciximab , Anciano , Anticuerpos Monoclonales/uso terapéutico , Femenino , Estudios de Seguimiento , Hemoptisis/terapia , Humanos , Fragmentos Fab de Inmunoglobulinas/uso terapéutico , Infarto del Miocardio/terapia , Intervención Coronaria Percutánea , Inhibidores de Agregación Plaquetaria/efectos adversos , Inhibidores de Agregación Plaquetaria/uso terapéutico , Complejo GPIIb-IIIa de Glicoproteína Plaquetaria/antagonistas & inhibidores , Alveolos Pulmonares
10.
Mediators Inflamm ; 2015: 379501, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25861161

RESUMEN

The use of combined hormonal contraceptives has been reported to increase the level of C-reactive protein (CRP). We assessed the effect of hormonal contraceptive use on inflammatory cytokines including CRP, monocyte chemotactic protein-1, soluble tumor necrosis factor (sTNF), interleukin-6 (IL-6), and soluble CD40 ligand. We used 79 female subjects (19 to 30 years old) who were combined oral contraceptives users (n = 29), combined vaginal contraceptive users (n = 20), and nonusers (n = 30) with CRP values of ≤1 (n = 46) or ≥3 (n = 33). Information on medical history, physical activities, and dietary and sleeping habits were collected. Both oral and vaginal contraceptive users had higher levels of CRP (P < 0.0001), compared to nonusers. Only oral contraceptive users exhibited elevated sCD40L (P < 0.01). When comparing the groups with CRP ≤ 1 and CRP ≥ 3, levels of IL-6 and sTNF-RI were positively correlated with CRP among oral contraceptive users. We did not observe the same elevation for other inflammatory biomarkers for the CRP ≥ 3 group among vaginal contraceptive users. The clear cause of elevation in CRP level due to the use of different hormonal contraceptive formulations and methods is not well understood. Longitudinal studies with larger sample size are required to better assess the true cause of CRP elevation among hormonal contraceptive users.


Asunto(s)
Proteína C-Reactiva/análisis , Dispositivos Anticonceptivos Femeninos , Anticonceptivos Hormonales Orales/farmacología , Adulto , Biomarcadores/sangre , Ligando de CD40/sangre , Femenino , Humanos , Interleucina-6/sangre , Receptores Tipo I de Factores de Necrosis Tumoral/sangre
11.
Artículo en Inglés | MEDLINE | ID: mdl-38950772

RESUMEN

OBJECTIVE: Aortic root replacement requires construction of a composite valve-graft and reimplantation of coronary arteries. This study assessed the feasibility of valve-in-valve transcatheter aortic valve implantation after aortic root replacement. METHODS: A retrospective review was conducted on 74 consecutive patients who received a composite valve-graft at a single institution from 2019 to 2021. Forty patients had bioprosthetic valves with adequate postoperative gated computed tomographic angiography scans. Computational simulations of balloon and self-expanding transcatheter valve deployments were performed. The modeled coronary distances were compared with traditional, manually measured valve-to-coronary distances. RESULTS: There was a statistically significant difference in the modeled versus manual measurements of valve to coronary distances for all patients regardless of valve type or coronary artery analyzed (P < .05). Most patients are low risk for coronary obstruction per 3-dimensional modeling, including those with a valve-to-coronary distance <4 mm. Only 1 patient (2.5%) was at risk for coronary obstruction for the left coronary artery using a balloon valve. No other valve combination was considered high risk of coronary obstruction. Five patients (12.5%) were at risk for possible valve stent deformation at the outflow, due to angulation at the graft anastomosis. CONCLUSIONS: Following aortic root replacement, all patients were candidates for valve-in-valve procedure using 1 or both types of transcatheter heart valves. Self-expanding valves may be at higher risk for stent frame deformation at graft anastomotic lines and balloon-expandable valves may be at higher risk of coronary obstruction.

12.
JACC Asia ; 4(4): 292-302, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38660112

RESUMEN

Background: Sex-related disparities in clinical outcomes following transcatheter aortic valve replacement (TAVR) and the impact of sex on clinical outcomes after TAVR among different racial groups are undetermined. Objectives: This study assessed whether sex-specific differences in baseline clinical and anatomical characteristics affect clinical outcomes after TAVR and investigated the impact of sex on clinical outcomes among different racial groups. Methods: The TP-TAVR (Trans-Pacific TAVR) registry is a multinational cohort study of patients with severe aortic stenosis who underwent TAVR at 2 major centers in the United States and 1 major center in South Korea. The primary outcome was a composite of death from any cause, stroke, or rehospitalization after 1 year. Results: The incidence of the primary composite outcome was not significantly different between sexes (27.9% in men vs 28% in women; adjusted HR: 0.97; 95% CI: 0.79-1.20). This pattern was consistent in Asian (23.5% vs 23.3%; adjusted HR: 0.99; 95% CI: 0.69-1.41) and non-Asian (30.8% vs 31.6%; adjusted HR: 0.95; 95% CI: 0.72-1.24) cohorts, without a significant interaction between sex and racial group (P for interaction = 0.74). The adjusted risk for all-cause mortality was similar between sexes, regardless of racial group. However, the adjusted risk of stroke was significantly lower in male patients than in female patients, which was more prominent in the non-Asian cohort. Conclusions: Despite significantly different baseline and procedural characteristics, there were no sex-specific differences in the adjusted 1-year rates of primary composite outcomes and all-cause mortality, regardless of different racial groups. (Transpacific TAVR registry [TP-TAVR]; NCT03826264).

13.
Ann Thorac Surg ; 118(2): 430-438, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38286202

RESUMEN

BACKGROUND: The management of aortic stenosis has evolved to stratification by age as reflected in recent societal guidelines. We evaluated age-stratified surgical aortic valve replacement (SAVR) trends and outcomes in patients with bicuspid aortic valve (BAV) or tricuspid aortic valve (TAV) from The Society of Thoracic Surgeons Adult Cardiac Surgery Database. METHODS: This cohort included adults (≥18 years) undergoing SAVR for severe aortic stenosis between July 2011 and December 2022. Comparisons were stratified by age (<65 years, 65-79 years, ≥80 years) and BAV or TAV status. Primary end points included operative mortality, composite morbidity and mortality, and permanent stroke. Observed to expected ratios by The Society of Thoracic Surgeons predicted risk of mortality were calculated. RESULTS: In total, 200,849 SAVR patients (55,326 BAV [27.5%], 145,526 TAV [72.5%]) from 1238 participating hospitals met study criteria. Annual SAVR volumes decreased by 45% (19,560 to 10,851) during the study period. The decrease was greatest (96%) for patients ≥80 years of age (4914 to 207). The relative prevalence of BAV was greater in younger patients (<65 years, 69,068 [49.5% BAV]; 65-79 years, 104,382 [19.1% BAV]; ≥80 years, 27,399 [4.5% BAV]). The observed mortality in <80-year-old BAV patients (<65 years, 1.08; 65-79 years, 1.21; ≥80 years, 3.68) was better than the expected mortality rate (<65 years, 1.22; 65-79 years, 1.54; ≥80 years, 3.14). CONCLUSIONS: SAVR volume in the transcatheter era has decreased substantially, particularly for patients ≥80 years old and for those with TAV. Younger patients with BAV have better than expected outcomes, which should be carefully considered during shared decision-making in the treatment of aortic stenosis. SAVR should remain the preferred therapy in this population.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Humanos , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/mortalidad , Anciano , Masculino , Femenino , Anciano de 80 o más Años , Factores de Edad , Implantación de Prótesis de Válvulas Cardíacas/métodos , Persona de Mediana Edad , Válvula Aórtica/cirugía , Válvula Aórtica/anomalías , Estudios Retrospectivos , Resultado del Tratamiento , Complicaciones Posoperatorias/epidemiología
14.
JACC Heart Fail ; 12(8): 1425-1438, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38934964

RESUMEN

BACKGROUND: The REDUCE LAP-HF II (Reduce Elevated Left Atrial Pressure in Patients With Heart Failure II) trial found that, compared with a sham procedure, the Corvia Atrial Shunt did not improve outcomes in heart failure with preserved or mildly reduced ejection fraction. However, after 12-month follow-up, "responders" (peak-exercise pulmonary vascular resistance <1.74 WU and absence of a cardiac rhythm management device) were identified. OBJECTIVES: This study sought to determine: 1) the overall efficacy and safety of the atrial shunt vs sham control after 2 years of follow-up; and 2) whether the benefits of atrial shunting are sustained in responders during longer-term follow-up or are offset by adverse effects of the shunt. METHODS: The study analyzed 2-year outcomes in the overall REDUCE LAP-HF II trial, as well as in responder and nonresponder subgroups. The primary endpoint was a hierarchical composite of cardiovascular death or nonfatal ischemic/embolic stroke, total heart failure events, and change in health status. RESULTS: In 621 randomized patients, there was no difference between the shunt (n = 309) and sham (n = 312) groups in the primary endpoint (win ratio: 1.01 [95% CI: 0.82-1.24]) or its individual components at 2 years. Shunt patency at 24 months was 98% in shunt-treated patients. Cardiovascular mortality and nonfatal ischemic stroke were not different between the groups; however, major adverse cardiac events were more common in those patients assigned to the shunt compared with sham (6.9% vs 2.7%; P = 0.018). More patients randomized to the shunt had an increase in right ventricular volume of ≥30% compared with the sham control (39% vs 28%, respectively; P < 0.001), but right ventricular dysfunction was uncommon and not different between the treatment groups. In responders (n = 313), the shunt was superior to sham (win ratio: 1.36 [95% CI: 1.02-1.83]; P = 0.037, with 51% fewer HF events [incidence rate ratio: 0.49 [95% CI: 0.25-0.95]; P = 0.034]). In nonresponders (n = 265), atrial shunting was inferior to sham (win ratio: 0.73 [95% CI: 0.54-0.98]). CONCLUSIONS: At 2 years of follow-up in REDUCE LAP-HF II, there was no difference in efficacy between the atrial shunt and sham groups in the overall trial group. The potential clinical benefit identified in the responder group after 1 and 2 years of follow-up is currently being evaluated in the RESPONDER-HF (Re-Evaluation of the Corvia Atrial Shunt Device in a Precision Medicine Trial to Determine Efficacy in Mildly Reduced or Preserved Ejection Fraction Heart Failure) trial. (Reduce Elevated Left Atrial Pressure in Patients With Heart Failure II [REDUCE LAP-HF II]; NCT03088033).


Asunto(s)
Atrios Cardíacos , Insuficiencia Cardíaca , Volumen Sistólico , Humanos , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/cirugía , Insuficiencia Cardíaca/terapia , Femenino , Masculino , Volumen Sistólico/fisiología , Anciano , Persona de Mediana Edad , Atrios Cardíacos/fisiopatología , Resultado del Tratamiento , Estudios de Seguimiento , Presión Atrial/fisiología
15.
Front Cardiovasc Med ; 10: 1204736, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37363090

RESUMEN

We present unusual coronary-pulmonary collaterals in a 65-year-old CTEPH patient. Perfusion mapping of a dual-energy computed tomography (DECT) study revealed areas of right lung that were minimally perfused despite unilateral occlusion of the right pulmonary artery, leading to the discovery of coronary-pulmonary collaterals via invasive coronary angiography. Pulmonary thromboendarterectomy removed the clot en-bloc. Post-surgery DECT and catheterization confirmed restoration of pulmonary arterial circulation and excellent hemodynamic response. Here, suggestion of perfusion to a proximally obstructed lung with DECT helped to document the presence of rarely documented coronary-pulmonary artery collaterals.

16.
Clin Case Rep ; 11(11): e8052, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37927980

RESUMEN

We present a case of a quadriplegic male who developed ventricular fibrillation associated with an anomalous aortic origin of the right coronary artery. Successful revascularization was achieved with percutaneous coronary intervention. This case highlights the application of an unconventional approach to resolve ischemia in a patient with prohibitive surgical risk.

17.
Cardiovasc Revasc Med ; 53: 13-19, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-36997465

RESUMEN

BACKGROUND: Patients with aortic stenosis (AS) usually have concomitant calcified coronary artery disease (CAD) requiring atherectomy to improve lesion compliance and odds of successful percutaneous coronary intervention (PCI). However, there is a paucity of data regarding PCI with or without atherectomy in patients with AS. METHODS: The National Inpatient Sample (NIS) database was queried from 2016 through 2019 using ICD-10 codes to identify individuals with AS who underwent PCI with or without atherectomy (Orbital Atherectomy [OA], Rotational or Laser Atherectomy [non-OA]). Temporal trends, safety, outcomes, costs, and correlates of major adverse cardiovascular events (MACE) were assessed using discharge weighted data. RESULTS: Hospitalizations of 45,420 AS patients undergoing PCI with or without atherectomy were identified and of those, 88.6 %, 2.3 %, and 9.1 % were treated with PCI-only, OA, or non-OA, respectively. There was an increase in PCIs (8855 to 10,885), atherectomy [OA (165 to 300) and non-OA (795 to 1255)], and intravascular ultrasound (IVUS) use (625 to 1000). The median cost of admission was higher in the atherectomy cohorts ($34,340.77 in OA, $32,306.2 in non-OA) as compared to the PCI-only cohort ($23,683.98). Patients tend to have decreased odds of MACE with IVUS guided atherectomy and PCI. CONCLUSIONS: This large database revealed a significant increase in PCI with or without atherectomy in AS patients from 2016 to 2019. Considering the complex comorbidities of AS patients, the overall complication rates were well distributed among the different cohorts, suggesting that IVUS guided PCI with or without atherectomy in patients with AS is feasible and safe.


Asunto(s)
Estenosis de la Válvula Aórtica , Aterectomía Coronaria , Enfermedad de la Arteria Coronaria , Intervención Coronaria Percutánea , Calcificación Vascular , Humanos , Intervención Coronaria Percutánea/efectos adversos , Pacientes Internos , Resultado del Tratamiento , Calcificación Vascular/diagnóstico por imagen , Calcificación Vascular/terapia , Calcificación Vascular/complicaciones , Aterectomía Coronaria/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/complicaciones , Aterectomía/efectos adversos , Estenosis de la Válvula Aórtica/complicaciones , Angiografía Coronaria
18.
JACC Asia ; 3(3): 376-387, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37323869

RESUMEN

Background: Interracial differences in the distribution and prognostic value of conventional Society of Thoracic Surgeons (STS) score on long-term mortality after transcatheter aortic valve replacement (TAVR) are uncertain. Objectives: This study aims to compare the impact of STS scores on clinical outcomes at 1-year after TAVR between Asian and non-Asian populations. Methods: We used the Trans-Pacific TAVR (TP-TAVR) registry, a multinational multicenter, observational registry involving patients undergoing TAVR at 2 major centers in the United States and 1 major center in Korea. Patients were classified into 3 groups (low, intermediate, and high-risk) according to the STS score and compared between STS risk groups and race. The primary outcome was all-cause mortality at 1-year. Results: Among 1,412 patients, 581 were Asian and 831 were non-Asian. The distribution of the STS risk score group was different between Asian and non-Asian groups (62.5% low-, 29.8% intermediate-, and 7.7% high-risk in Asian vs 40.6% low-, 39.1% intermediate-, and 20.3% high-risk in non-Asian). In the Asian population, the all-cause mortality at 1-year was substantially higher in the high-risk STS group than in the low- and intermediate-risk groups (3.6% low-risk, 8.7% intermediate-risk, and 24.4% high-risk; log-rank P < 0.001), which was primarily driven by noncardiac mortality. In the non-Asian group, there was a proportional increase in all-cause mortality at 1-year according to the STS risk category (5.3% low-risk, 12.6% intermediate-risk, and 17.8% high-risk; log-rank P < 0.001). Conclusions: In this multiracial registry of patients with severe aortic stenosis who underwent TAVR, we identified a differential proportion and prognostic impact of STS score on 1-year mortality between Asian and non-Asian patients (TP-TAVR [Transpacific TAVR Registry]; NCT03826264).

19.
Am J Cardiol ; 189: 76-85, 2023 02 15.
Artículo en Inglés | MEDLINE | ID: mdl-36512989

RESUMEN

The use of mechanical circulatory support (MCS) in chronic total occlusion (CTO) percutaneous coronary intervention (PCI) has received limited study. We analyzed the clinical and angiographic characteristics, and procedural outcomes of 7,171 CTO PCIs performed between 2012 and 2021 at 35 international centers. Mean age was 64.5 ± 10 years, mean left ventricular ejection fraction was 50 ± 13%. MCS was used in 4.5%, prophylactically in 78.7%, and urgently in 21.3%. The most common type of MCS overall was Impella CP (Abiomed) (55.5%), followed by intra-aortic balloon pump (14.8%) and TandemHeart (LivaNova Inc.) (10.0%). Prophylactic MCS patients were more likely to have diabetes mellitus (55% vs 42%, p <0.001) and had more complex lesions compared with cases without prophylactic MCS (Japan-CTO score: 2.80 ± 1.22 vs 2.39 ± 1.27, p <0.001). Cases with prophylactic MCS had similar technical (86% vs 87%, p = 0.643) but lower procedural (80% vs 86%, p = 0.028) success rates and higher rates of periprocedural major cardiac adverse events compared with no prophylactic MCS use (6.55% vs 1.68%, p <0.001). Urgent MCS use was associated with lower technical (68% vs 87%, p <0.001) and procedural (39% vs 86%, p <0.001) success rates and higher major cardiac adverse events compared with no-MCS use (32.26% vs 1.68%, p <0.001). The differences persisted in multivariable analyses. In summary, in this contemporary multicenter registry, MCS was used in 4.5% of CTO PCIs, mostly prophylactically (78.7%). Elective MCS cases had similar technical success but a higher risk of complications. Urgent MCS cases had lower technical and procedural success and higher periprocedural major complication rates.


Asunto(s)
Oclusión Coronaria , Intervención Coronaria Percutánea , Humanos , Persona de Mediana Edad , Anciano , Resultado del Tratamiento , Factores de Riesgo , Intervención Coronaria Percutánea/efectos adversos , Volumen Sistólico , Función Ventricular Izquierda , Sistema de Registros , Angiografía Coronaria , Oclusión Coronaria/diagnóstico , Oclusión Coronaria/cirugía , Oclusión Coronaria/etiología , Enfermedad Crónica
20.
J Invasive Cardiol ; 34(3): E210-E217, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-35192504

RESUMEN

OBJECTIVE: Severely calcified coronary stenoses remain a significant challenge during contemporary percutaneous coronary intervention (PCI), often requiring advanced therapies to circumvent suboptimal lesion preparation and major adverse cardiac events (MACEs). Recent reports suggest combined coronary atherectomy and intravascular lithotripsy (IVL) may achieve superior preparation of severely calcified coronary stenoses during PCI. We sought to evaluate the safety and utility of combined orbital atherectomy (OA) and IVL for the modification of coronary artery calcification (CAC) prior to drug-eluting stent (DES) implantation in PCI. METHODS: We performed a retrospective review of all patients who underwent coronary OA and IVL within a single PCI procedure at our institution. The primary outcome was procedural success, defined as successful DES implantation with a residual percent diameter stenosis of <30% and Thrombolysis in Myocardial Infarction (TIMI) 3 flow following PCI without occurrence of in-hospital MACE (cardiac death, myocardial infarction, or target-vessel revascularization). MACE was additionally assessed at 30 days post intervention. RESULTS: Eight patients underwent combined coronary OA and IVL within a single PCI procedure. The mean percent diameter stenosis prior to intervention was 80.5 ± 8.3%, with a mean calcific arc of 338 ± 42°. Procedural success was achieved in 7 of 8 cases (87.5%). Both in-hospital and 30-day MACE rates were 0%. CONCLUSION: We report the safe and effective use of combined coronary OA and IVL for the preparation of severely calcified coronary stenoses during PCI. Through their distinct yet complementary mechanisms of action, the combined use of these therapies may achieve superior preparation of severely calcified coronary stenoses during PCI.


Asunto(s)
Aterectomía Coronaria , Enfermedad de la Arteria Coronaria , Estenosis Coronaria , Stents Liberadores de Fármacos , Litotricia , Infarto del Miocardio , Intervención Coronaria Percutánea , Calcificación Vascular , Aterectomía , Aterectomía Coronaria/efectos adversos , Constricción Patológica/etiología , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/cirugía , Estenosis Coronaria/diagnóstico , Estenosis Coronaria/cirugía , Humanos , Litotricia/efectos adversos , Infarto del Miocardio/etiología , Intervención Coronaria Percutánea/efectos adversos , Resultado del Tratamiento , Calcificación Vascular/diagnóstico , Calcificación Vascular/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA