Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 47
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Medicina (Kaunas) ; 57(8)2021 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-34440996

RESUMEN

Background and Objectives: Femoral neck fractures are common and constitute one of the largest healthcare burdens of the modern age. Fractures within the joint capsule (intracapsular) provide a specific surgical challenge due to the difficulty in predicting rates of bony union and whether the blood supply to the femoral head has been disrupted in a way that would lead to avascular necrosis. Most femoral neck fractures are treated surgically, aiming to maintain mobility, whilst reducing pain and complications associated with prolonged bedrest. Materials and Methods: We performed a narrative review of intracapsular hip fracture management, highlighting the latest advancements in fixation techniques, generating an evidence-based algorithm for their management. Results: Multiple different fracture configurations are encountered within the category of intracapsular hip fractures, with each pattern having different optimal surgical strategies. Additionally, these injuries typically occur in patients where further procedures due to operative complications are associated with a considerable increase in mortality, highlighting the need for choosing the correct index operation. Conclusions: Factors such as pathological causes for the fracture, pre-existing symptomatic osteoarthritis, patient's physiological age and fracture displacement all need to be considered when choosing optimal management.


Asunto(s)
Fracturas del Cuello Femoral , Algoritmos , Fracturas del Cuello Femoral/cirugía , Cabeza Femoral , Fijación Interna de Fracturas , Humanos , Resultado del Tratamiento
2.
J Shoulder Elbow Surg ; 28(9): 1816-1823, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31036421

RESUMEN

BACKGROUND: Proximal humeral fractures occur frequently, with fixed angle locking plates often being used for their treatment. No current quantitative evidence for the effect of different screw configurations exists, and the large number of variations makes biomechanical testing prohibitive. Therefore, we used an established and validated finite element osteosynthesis test kit to quantify the effect of variations in screw configuration on predicted failure risk of PHILOS plate fixation for unstable proximal humerus fractures. METHODS: Twenty-six low-density humerus models were osteotomized to create malreduced unstable 3-part fractures that were virtually fixed with PHILOS plates. Twelve screw configurations were simulated: 6 using 2 screw rows, 4 using 3 rows, and 1 with either 8 or 9 screws. Three physiological loading cases were modeled and an established finite element analysis methodology was used. The average peri-screw bone strain, previously demonstrated to predict fatigue cutout failure, was used to compare the different configurations. RESULTS: Significant differences in peri-screw strains, and thus predicted failure risk, were seen with different combinations. The 9-screw configuration demonstrated the lowest peri-screw strains. Fewer screw constructs showed lower strains when placed further apart. The calcar screws (row E) significantly (P < .001) reduced fixation failure risk. CONCLUSION: Screw configurations significantly impact predicted cutout failure risk for locking plate fixations of unstable proximal humerus fractures in low-density bone. Although requiring clinical corroboration, the result of this study suggests that additional screws reduce peri-screw strains, the distance between them should be maximized whenever possible and the calcar screws should be used.


Asunto(s)
Placas Óseas , Tornillos Óseos , Fijación Interna de Fracturas/instrumentación , Fracturas del Hombro/cirugía , Fenómenos Biomecánicos , Epífisis/lesiones , Epífisis/cirugía , Análisis de Falla de Equipo , Análisis de Elementos Finitos , Fijación Interna de Fracturas/métodos , Humanos , Masculino , Falla de Prótesis
3.
Arch Orthop Trauma Surg ; 139(8): 1069-1074, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-30895465

RESUMEN

BACKGROUND: The aim of this study was to identify the effect of screw length on predictions of fixation failure in three-part proximal humeral fractures using a finite element-based osteosynthesis modelling toolkit. METHODS: A mal-reduced unstable three-part AO/OTA 11-B3.2 fracture with medial comminution was simulated in forty-two digitally processed proximal humeri covering a spectrum of bone densities and fixed with the PHILOS plate using three distal and six proximal locking screws. Four test groups were generated based on the screw tip to joint surface distance (TJD), with all proximal screws being shortened from 4 mm TJD to be 8, 12 or 16 mm TJD. Average bone strains around the screw tips, correlating with biomechanical cyclic cut-out-type failure, were evaluated in three physiological loading protocols representing simple shoulder motions. Six further groups were tested, where five of the proximal screws were inserted to 4 mm TJD and the sixth screw to 8 mm TJD. RESULTS: Exponential increases in the predicted risk of fixation failure were seen with increased tip-to-joint distances (p < 0.001). When one of the proximal screws was placed 8 mm from the joint, with the remaining five at 4 mm distance, significant increases (p < 0.001) were registered in the strains around the screw tips in all except the two superior screws. This effect was maximal around the calcar screws (p < 0.001) and for lower density samples (p < 0.001). CONCLUSIONS: These results suggest that longer screws provide reduced risk of cut-out failure, i.e. distalisation and/or varisation of the head fragment, and thus may decrease failure rates in proximal humeral fractures treated with angular stable plates. These findings require clinical corroboration and further studies to investigate the risk of screw perforation.


Asunto(s)
Tornillos Óseos , Simulación por Computador , Análisis de Elementos Finitos , Fijación Interna de Fracturas/métodos , Fracturas del Hombro/cirugía , Anciano , Anciano de 80 o más Años , Placas Óseas , Femenino , Fijación Interna de Fracturas/instrumentación , Fracturas Conminutas/diagnóstico por imagen , Fracturas Conminutas/cirugía , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Fracturas del Hombro/diagnóstico por imagen , Tomografía Computarizada por Rayos X
4.
J Vasc Interv Radiol ; 25(10): 1595-603, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25156647

RESUMEN

PURPOSE: To characterize the distribution of absorbed radiation dose after glass microsphere radioembolization for hepatocellular carcinoma (HCC) using yttrium-90 ((90)Y) positron emission tomography/computed tomography (PET/CT). MATERIALS AND METHODS: In this retrospective study, 64 (90)Y PET/CT scans performed after treatment were evaluated following (90)Y glass-bead radioembolization in patients with advanced HCC. The intended dose to the target volume ranged from 83-129 Gy. Three-dimensional "dose maps" were created from reconstructed PET images using a voxel-based S-value transformation. Liver parenchyma and liver tumors were contoured on cross-sectional imaging and aligned with the created dose maps. RESULTS: There were 113 tumors examined as part of 64 lobar treatments. The average tumor size was 4.8 cm ± 4.0 with an average tumor dose of 173 Gy ± 109. The average dose to the nontumor parenchyma within the target volume was 93.4 Gy ± 32.6, with on average 50% of the parenchymal voxels receiving > 79 Gy ± 23 and 10% receiving > 173 Gy ± 55. The average and median tumor-to-parenchymal weighted dose ratios were 2.2 and 1.9, respectively. CONCLUSIONS: Using recommended dosimetry and administration techniques for lobar glass microsphere radioembolization, high doses to target tumors as well as background parenchyma were achieved on average with modest preferential uptake within tumors. There was wide variation in measured tumor and parenchymal doses after hepatic radioembolization for HCC, suggesting the need for continued development of patient-specific dosimetry.


Asunto(s)
Carcinoma Hepatocelular/radioterapia , Embolización Terapéutica/métodos , Arteria Hepática , Neoplasias Hepáticas/radioterapia , Imagen Multimodal/métodos , Tomografía de Emisión de Positrones , Radiofármacos/administración & dosificación , Dosificación Radioterapéutica , Tomografía Computarizada por Rayos X , Radioisótopos de Itrio/administración & dosificación , Anciano , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/patología , Embolización Terapéutica/efectos adversos , Femenino , Vidrio , Humanos , Inyecciones Intraarteriales , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/patología , Masculino , Microesferas , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Radiofármacos/efectos adversos , Estudios Retrospectivos , Resultado del Tratamiento , Carga Tumoral , Radioisótopos de Itrio/efectos adversos
5.
Plast Reconstr Surg Glob Open ; 12(4): e5766, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38645630

RESUMEN

Unlike other body parts, the upper extremity has critical structures close to the skin, making soft tissue injuries more complex. These injuries can result from various causes, including trauma and necrotizing soft tissue infections, necessitating reconstruction. Historically, pedicled flaps from the groin and abdomen were commonly used for upper extremity reconstruction, but they had limitations, such as the need for flap division and debulking, patient discomfort, and stiffness. Free flap reconstruction has become the preferred method, but it still faces challenges like patient and facility issues, the absence of recipient vessels after injury, and multi-surface wounds. This case report describes a 67-year-old patient with a severe necrotizing soft tissue infection in the right upper extremity. After multiple debridement procedures, the patient underwent hand amputation and soft tissue coverage using an abdominal wall-based flap. The objectives of achieving stable soft tissue coverage while preserving maximal length of the upper extremity were successfully achieved, and the patient expressed satisfaction with the outcomes. Inadequate management of upper extremity wounds can lead to amputation and psychological distress. The reconstructive ladder is used to approach upper extremity soft tissue defects, with free tissue transfer being the standard for larger defects. However, abdominal flaps still have indications when free tissue transfer is not feasible or contraindicated. It is imperative that plastic surgeons have these techniques in their armamentarium to provide a service to the ever more complex patient with an upper extremity wound.

6.
Lancet Oncol ; 13(12): 1218-24, 2012 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23099009

RESUMEN

BACKGROUND: Plexiform neurofibromas are slow-growing chemoradiotherapy-resistant tumours arising in patients with neurofibromatosis type 1 (NF1). Currently, there are no viable therapeutic options for patients with plexiform neurofibromas that cannot be surgically removed because of their proximity to vital body structures. We undertook an open-label phase 2 trial to test whether treatment with imatinib mesylate can decrease the volume burden of clinically significant plexiform neurofibromas in patients with NF1. METHODS: Eligible patients had to be aged 3-65 years, and to have NF1 and a clinically significant plexiform neurofibroma. Patients were treated with daily oral imatinib mesylate at 220 mg/m(2) twice a day for children and 400 mg twice a day for adults for 6 months. The primary endpoint was a 20% or more reduction in plexiform size by sequential volumetric MRI imaging. Clinical data were analysed on an intention-to-treat basis; a secondary analysis was also done for those patients able to take imatinib mesylate for 6 months. This trial is registered with ClinicalTrials.gov, number NCT01673009. FINDINGS: Six of 36 patients (17%, 95% CI 6-33), enrolled on an intention-to-treat basis, had an objective response to imatinib mesylate, with a 20% or more decrease in tumour volume. Of the 23 patients who received imatinib mesylate for at least 6 months, six (26%, 95% CI 10-48) had a 20% or more decrease in volume of one or more plexiform tumours. The most common adverse events were skin rash (five patients) and oedema with weight gain (six). More serious adverse events included reversible grade 3 neutropenia (two), grade 4 hyperglycaemia (one), and grade 4 increases in aminotransferase concentrations (one). INTERPRETATION: Imatinib mesylate could be used to treat plexiform neurofibromas in patients with NF1. A multi-institutional clinical trial is warranted to confirm these results. FUNDING: Novartis Pharmaceuticals, the Indiana University Simon Cancer Centre, and the Indiana University Herman B Wells Center for Pediatric Research.


Asunto(s)
Antineoplásicos/uso terapéutico , Neurofibroma Plexiforme/tratamiento farmacológico , Neurofibromatosis 1/complicaciones , Piperazinas/uso terapéutico , Inhibidores de Proteínas Quinasas/uso terapéutico , Pirimidinas/uso terapéutico , Adolescente , Adulto , Benzamidas , Niño , Preescolar , Femenino , Humanos , Mesilato de Imatinib , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Neurofibroma Plexiforme/complicaciones , Neurofibroma Plexiforme/patología , Adulto Joven
7.
Cureus ; 15(7): e41808, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37575707

RESUMEN

BACKGROUND: Dual airbags are required to be installed and available for use in all motor vehicles since 1997. The National Highway Traffic Safety Administration reported that 50,457 lives were saved by airbags from 1987 to 2017; however, airbag deployment can cause injuries, including thermal and chemical burns, hyperpigmentation, and dysaesthesia. There is little information available in the literature regarding differences in outcomes between promptly visiting a plastic surgeon and waiting for treatment, especially as an injury may not be immediately apparent or patients may not know that airbag burn injuries may be delayed in presenting. METHODS: This is a retrospective cohort pilot study conducted among 14 patients who presented to a plastic surgeon between January 1, 2019 and June 30, 2022 owing to injuries from airbag deployment. An early visit was considered ≤30 days, and a late visit was >30 days. Other variables collected included age, sex, Fitzpatrick skin type, smoking status, comorbidities, type of injury, injury site, pain status, hyper/hypopigmentation, dysaesthesia, epithelialization, and improvements in pain, pigmentation, and dysaesthesia from treatment. RESULTS: The mean age was 36.0 years (standard deviation (SD) 17.9). The majority were female (85.7%), non-smokers (87.5%), and not diabetic (75.0%). Only six patients (42.9%) visited their doctor within one month of injury. Most patients experienced dysaesthesia (85.7%) and pain (71.4%). Thirteen of the 14 patients had hyperpigmentation or hyperemia, and one had hypopigmentation. Full or slight epithelialization was seen in 35.7%, and nine of the 14 patients had no epithelialization. Ongoing issues were a factor for 64.3% of these patients; 42.9% had ongoing issues with hyperpigmentation. A full recovery was seen in 28.6% of the patients. The patients who saw the plastic surgeon by day 30 or less (early) from the time of injury had a 66.7% improvement in pigmentation and 33.3% resolution in pain. Of those who went to the surgeon beyond 30 days (late), 25% had improvement in pigmentation and 37.5% had resolution of pain. Improvement in dysaesthesia occurred in both groups, but those who saw the plastic surgeon early had 33.3% resolution, while 37.5% of those who went late improved. Of those who went late to the surgeon, only 12.5% had epithelialization, while 66.7% of those who went within 30 days showed signs of (full or slight) epithelialization. CONCLUSION: Patients involved in motor vehicle collisions (MVCs) should be informed of the delayed fashion in which airbag burns can develop. An ostensibly mild burn may portend long-term consequences, especially if such injuries are not addressed in a prompt manner. Our study demonstrates how airbag burn injuries and their sequelae are best addressed with early care.

8.
J Clin Med ; 12(4)2023 Feb 17.
Artículo en Inglés | MEDLINE | ID: mdl-36836132

RESUMEN

(1) Background: Unstable meta-diaphyseal tibial fractures represent a heterogeneous group of injuries. Recently, good clinical results have been reported when applying a technique of externalized locked plating in appropriate cases, highlighting its advantage in terms of less additional tissue injury compared with conventional methods of fracture fixation. The aims of this prospective clinical cohort study were, firstly, to investigate the biomechanical and clinical feasibility and, secondly, to evaluate the clinical and functional outcomes of single-stage externalized locked plating for treatment of unstable, proximal (intra- and extra-articular) and distal (extra-articular), meta-diaphyseal tibial fractures. (2) Methods: Patients, who matched the inclusion criteria of sustaining a high-energy unstable meta-diaphyseal tibial fracture, were identified prospectively for single-stage externalized locked plating at a single trauma hospital in the period from April 2013 to December 2022. (3) Results: Eighteen patients were included in the study. Average follow-up was 21.4 ± 12.3 months, with 94% of the fractures healing without complications. The healing time was 21.1 ± 4.6 weeks, being significantly shorter for patients with proximal extra- versus intra-articular meta-diaphyseal tibial fractures, p = 0.04. Good and excellent functional outcomes in terms of HSS and AOFAS scores, and knee and ankle joints range of motion were observed among all patients, with no registered implant breakage, deep infection, and non-union. (4) Conclusions: Single-stage externalized locked plating of unstable meta-diaphyseal tibial fractures provides adequate stability of fixation with promising clinical results and represents an attractive alternative to the conventional methods of external fixation when inclusion criteria and rehabilitation protocol are strictly followed. Further experimental studies and randomized multicentric clinical trials with larger series of patients are necessary to pave the way of its use in clinical practice.

9.
J Mech Behav Biomed Mater ; 126: 105002, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34894498

RESUMEN

Screws are the most frequently used implants for treatment of bone fractures and play an essential role in determining fixation stability. Robust prediction of the bone-screw interface failure would enable development of improved fixation strategies and implant designs, ultimately reducing failure rates and improving outcomes of bone fracture treatments. This study aimed to compare the accuracy of micro-computed tomography image based bone volume measures, linear micro-finite element (FE) and non-linear micro-FE simulations in predicting pull-out force of 3.5 mm screws in human cadaveric tibial cortical bone. Axial pull-out experiments were performed in forty samples harvested from a single human tibia to measure ultimate force, which was correlated with bone volume around the screw and the predictions by both linear micro-FE and non-linear explicit micro-FE models. Correlation strength was similar for bone volume around the screw (R2 = 0.866) and linear micro-FE (R2 = 0.861), but the explicit non-linear micro-FE models were able to capture the experimental results more accurately (R2 = 0.913) and quantitatively correctly. Therefore, this technique may have potential for future in silico studies aiming at implant design optimization.


Asunto(s)
Tornillos Óseos , Tibia , Fenómenos Biomecánicos , Hueso Cortical/diagnóstico por imagen , Análisis de Elementos Finitos , Humanos , Microtomografía por Rayos X
10.
Sci Rep ; 12(1): 20076, 2022 11 22.
Artículo en Inglés | MEDLINE | ID: mdl-36418373

RESUMEN

Orthopaedic screws insertion can be trivialised as a simple procedure, however it is frequently performed poorly. Limited work exists defining how well surgeons insert screws or whether augmented screwdrivers can aid surgeons to reduce stripping rates and optimise tightness. We aimed to establish the performance of surgeons inserting screws and whether this be improved with screwdriver augmentation. 302 orthopaedic surgeons tightened 10 non-locking screws to what they determined to be optimum tightness into artificial bone sheets. The confidence in the screw purchase was given (1-10). A further 10 screws were tightened, using an augmented screwdriver that indicated when a predetermined optimum tightness was reached. The tightness for unstripped insertions under normal conditions and with the augmented screwdriver were 81% (95% CI 79-82%)(n = 1275) and 70% (95% CI 69-72%)(n = 2577) (p < 0.001). The stripping rates were 58% (95% CI 54-61%) and 15% (95% CI 12-17%) respectively (p < 0.001). The confidences when using the normal and augmented screwdrivers respectively were 7.2 and 7.1 in unstripped insertions and 6.2 and 6.5 in stripped insertions. Performance improved with an augmented screwdriver, both in reduced stripping rates and greater accuracy in detecting stripping. Augmenting screwdrivers to indicate optimum tightness offer potentially enormous clinical benefits by improving screw fixation.


Asunto(s)
Cirujanos Ortopédicos , Ortopedia , Cirujanos , Humanos , Fijadores Internos , Tornillos Óseos
11.
J Trauma ; 71(6): 1709-14, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22002619

RESUMEN

BACKGROUND: Tibia fractures may require soft tissue coverage with transposed tissue and can develop nonunions. Tibial defects can be approached with a posterolateral approach or by elevating the previously transposed tissue. No literature has previously reported the efficacy or safety of the latter approach. The purpose of this study was to report the flap survival rate and complications from delayed elevation of transposed soft tissue as part of a protocol for the treatment of tibia nonunions. METHODS: In a retrospective review of patients having local, regional, or free soft tissue transposition for the management of open type III B high-energy tibial fractures and also requiring secondary procedures on the same tibia for treatment of tibial nonunion and/or osteomyelitis that required flap elevation, 23 patients with 24 flaps were identified and studied. The 24 flaps were elevated a total of 72 times as part of a staged protocol for nonunion reconstruction by a single surgeon. Primary end point was flap survival. Mean follow-up after definitive soft tissue coverage was 23.7 months. Mean follow-up after injury was 28.9 months. RESULTS: One flap failed after elevation. On a per elevation surgery basis, the flap survival rate was 98.6% (71 of 72). On a per flap basis, the flap survival rate was 95.8% (23 of 24). CONCLUSIONS: This is the first report of the survival and complication rates for delayed elevation of soft tissue flaps for tibial nonunion reconstruction. A total of 95.8% of flaps survived elevation. Flap elevation seems to be an alternative to posterolateral tibial approaches for treatment of tibial nonunions.


Asunto(s)
Fracturas Abiertas/cirugía , Fracturas no Consolidadas/cirugía , Supervivencia de Injerto , Colgajos Quirúrgicos , Fracturas de la Tibia/cirugía , Estudios de Cohortes , Femenino , Estudios de Seguimiento , Fracturas Abiertas/complicaciones , Fracturas Abiertas/diagnóstico por imagen , Fracturas no Consolidadas/diagnóstico , Humanos , Puntaje de Gravedad del Traumatismo , Masculino , Radiografía , Procedimientos de Cirugía Plástica/métodos , Estudios Retrospectivos , Medición de Riesgo , Fracturas de la Tibia/complicaciones , Fracturas de la Tibia/diagnóstico por imagen , Factores de Tiempo , Recolección de Tejidos y Órganos/métodos , Cicatrización de Heridas/fisiología
12.
J Orthop Case Rep ; 11(3): 85-89, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34239836

RESUMEN

INTRODUCTION: Infected non-unions of proximal femoral fractures are difficult to treat. If debridement and revision fixation is unsuccessful, staged revision arthroplasty may be required. Non-viable tissue must be resected; coupled with the introduction of an antibiotic-eluting temporary spacer before definitive reconstruction. Tissue microbiological diagnosis and targeted antibiotic therapy are required. In cases of significant proximal femoral bone loss, spacing options are limited. CASE REPORT: We present a case of a bisphosphonate-induced subtrochanteric fracture that progressed to infected non-union. Despite multiple washouts and two revision fixations, the infection remained active with an unfavorable antibiogram. The patient required staged revision arthroplasty including a proximal femoral resection. To improve function through maintaining leg length and offset, the Cement-a-TAN was fabricated. It is a custom-made antibiotic-eluting articulating temporary spacer. Using a trochanteric entry cephalocondylar nail as a scaffold, bone cement was molded around the nail to fashion an anatomical and patient-specific proximal femoral spacer. Following resolution of the infection, the Cement-a-TAN was removed and a proximal femoral arthroplasty was successfully performed. CONCLUSION: Cement-a-TAN is an excellent temporary spacing technique in staged proximal femoral replacement for infected non-union of the proximal femur where there has been significant bone loss. It preserves mobility and maintains leg length, offset, and periarticular soft-tissue tension, while offering good stability.

13.
J Orthop Surg Res ; 16(1): 642, 2021 Oct 26.
Artículo en Inglés | MEDLINE | ID: mdl-34702320

RESUMEN

BACKGROUND: Screws are the most frequently inserted orthopaedic implants. Biomechanical, laboratory-based studies are used to provide a controlled environment to investigate revolutionary and evolutionary improvements in orthopaedic techniques. Predominantly, biomechanical trained, non-surgically practicing researchers perform these studies, whilst it will be orthopaedic surgeons who will put these procedures into practice on patients. Limited data exist on the comparative performance of surgically and non-surgically trained biomechanical researchers when inserting screws. Furthermore, any variation in performance by surgeons and/or biomechanical researchers may create an underappreciated confounder to biomechanical research findings. This study aimed to identify the differences between surgically and non-surgically trained biomechanical researchers' achieved screw tightness and stripping rates with different fixation methods. METHODS: Ten orthopaedic surgeons and 10 researchers inserted 60 cortical screws each into artificial bone, for three different screw diameters (2.7, 3.5 and 4.5 mm), with 50% of screws inserted through plates and 50% through washers. Screw tightness, screw hole stripping rates and confidence in screw purchase were recorded. Three members of each group also inserted 30 screws using an augmented screwdriver, which indicated when optimum tightness was achieved. RESULTS: Unstripped screw tightness for orthopaedic surgeons and researchers was 82% (n = 928, 95% CI 81-83) and 76% (n = 1470, 95% CI 75-76) respectively (p < 0.001); surgeons stripped 48% (872/1800) of inserted screws and researchers 18% (330/1800). Using washers was associated with increased tightness [80% (95% CI 80-81), n = 1196] compared to screws inserted through plates [76% (95% CI 75-77), n = 1204] (p < 0.001). Researchers were more accurate in their overall assessment of good screw insertion (86% vs. 62%). No learning effect occurred when comparing screw tightness for the first 10 insertions against the last 10 insertions for any condition (p = 0.058-0.821). Augmented screwdrivers, indicating optimum tightness, reduced stripping rates from 34 to 21% (p < 0.001). Experience was not associated with improved performance in screw tightness or stripping rates for either group (p = 0.385-0.965). CONCLUSIONS: Surgeons and researchers showed different screw tightness under the same in vitro conditions, with greater rates of screw hole stripping by surgeons. This may have important implications for the reproducibility and transferability of research findings from different settings depending on who undertakes the experiments.


Asunto(s)
Tornillos Óseos , Competencia Clínica , Cirujanos Ortopédicos , Fenómenos Biomecánicos , Huesos , Humanos , Reproducibilidad de los Resultados , Torque
14.
Semin Ultrasound CT MR ; 31(6): 496-505, 2010 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-21147377

RESUMEN

The use of standardized uptake values (SUVs) is now common place in clinical 2-deoxy-2-[(18)F] fluoro-D-glucose (FDG) position emission tomography-computed tomography oncology imaging and has a specific role in assessing patient response to cancer therapy. Ideally, the use of SUVs removes variability introduced by differences in patient size and the amount of injected FDG. However, in practice there are several sources of bias and variance that are introduced in the measurement of FDG uptake in tumors and also in the conversion of the image count data to SUVs. In this article the overall imaging process is reviewed and estimates of the magnitude of errors, where known, are given. Recommendations are provided for best practices in improving SUV accuracy.


Asunto(s)
Fluorodesoxiglucosa F18/farmacocinética , Neoplasias/terapia , Tomografía de Emisión de Positrones/métodos , Radiofármacos/farmacocinética , Tomografía Computarizada por Rayos X/métodos , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Neoplasias/diagnóstico por imagen , Reproducibilidad de los Resultados , Resultado del Tratamiento
15.
Clin Biomech (Bristol, Avon) ; 80: 105152, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32866854

RESUMEN

BACKGROUND: Screw fixation in osteoporotic bone is clinically challenging. Screw failure rates are growing due to an increasing prevalence of osteoporosis. To address this, biomechanical models are needed to recreate the bone clinically encountered alongside the development of new operative techniques. The first aim of this study was to test whether the use of a smaller than recommended pilot-hole diameter improved pull-out strength for cancellous screws, with the second aim to create a model of low-density porcine bone for biomechanical testing. METHODS: Thirty porcine tibiae were cut into transverse metaphyseal sections of 20 mm thickness. Bone density was altered using 0.15 M Hydrochloric acid, and measured and pre- and post-demineralisation using HRµCT. Seventy-two screw areas were randomised to either 2.5 mm or 1.5 mm pilot holes and to either be normal or reduced density. Maximum axial pull-out strength was measured. FINDINGS: Demineralisation reduced bone density by 12% (p < 0.0001) and 11% (p < 0.0001) for 2.5 mm and 1.5 mm pilot hole diameters respectively. Pull-out strength reduced by 50% (p = 0.0001) and 44% (p < 0.0001) following demineralisation for both 2.5 mm and 1.5 mm pilot hole diameters. Pull-out strength increased by 51% (p = 0.0008) when inserting screws into 1.5 mm pilot holes in low density bone, and by 28% (p = 0.027) in normal bone. INTERPRETATION: Porcine bone can be demineralised to model low density cancellous bone. This novel model showed that pullout force is significantly reduced in lower density screw holes, but that this reduction can be mitigated by reducing pilot hole diameter for cancellous screws.


Asunto(s)
Densidad Ósea , Tornillos Óseos , Hueso Esponjoso/fisiología , Hueso Esponjoso/cirugía , Animales , Fenómenos Biomecánicos , Pruebas Mecánicas , Porcinos
16.
Bone Joint Res ; 9(8): 493-500, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32922757

RESUMEN

AIMS: To devise a method to quantify and optimize tightness when inserting cortical screws, based on bone characterization and screw geometry. METHODS: Cortical human cadaveric diaphyseal tibiae screw holes (n = 20) underwent destructive testing to firstly establish the relationship between cortical thickness and experimental stripping torque (Tstr), and secondly to calibrate an equation to predict Tstr. Using the equation's predictions, 3.5 mm screws were inserted (n = 66) to targeted torques representing 40% to 100% of Tstr, with recording of compression generated during tightening. Once the target torque had been achieved, immediate pullout testing was performed. RESULTS: Cortical thickness predicted Tstr (R2 = 0.862; p < 0.001) as did an equation based on tensile yield stress, bone-screw friction coefficient, and screw geometries (R2 = 0.894; p < 0.001). Compression increased with screw tightness up to 80% of the maximum (R2 = 0.495; p < 0.001). Beyond 80%, further tightening generated no increase in compression. Pullout force did not change with variations in submaximal tightness beyond 40% of Tstr (R2 = 0.014; p = 0.175). CONCLUSION: Screw tightening between 70% and 80% of the predicted maximum generated optimum compression and pullout forces. Further tightening did not considerably increase compression, made no difference to pullout, and increased the risk of the screw holes being stripped. While further work is needed for development of intraoperative methods for accurate and reliable prediction of the maximum tightness for a screw, this work justifies insertion torque being considerably below the maximum.Cite this article: Bone Joint Res 2020;9(8):493-500.

17.
Bone Joint Res ; 9(9): 534-542, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32922762

RESUMEN

AIMS: Fixation of osteoporotic proximal humerus fractures remains challenging even with state-of-the-art locking plates. Despite the demonstrated biomechanical benefit of screw tip augmentation with bone cement, the clinical findings have remained unclear, potentially as the optimal augmentation combinations are unknown. The aim of this study was to systematically evaluate the biomechanical benefits of the augmentation options in a humeral locking plate using finite element analysis (FEA). METHODS: A total of 64 cement augmentation configurations were analyzed using six screws of a locking plate to virtually fix unstable three-part fractures in 24 low-density proximal humerus models under three physiological loading cases (4,608 simulations). The biomechanical benefit of augmentation was evaluated through an established FEA methodology using the average peri-screw bone strain as a validated predictor of cyclic cut-out failure. RESULTS: The biomechanical benefit was already significant with a single cemented screw and increased with the number of augmented screws, but the configuration was highly influential. The best two-screw (mean 23%, SD 3% reduction) and the worst four-screw (mean 22%, SD 5%) combinations performed similarly. The largest benefits were achieved with augmenting screws purchasing into the calcar and having posteriorly located tips. Local bone mineral density was not directly related to the improvement. CONCLUSION: The number and configuration of cemented screws strongly determined how augmentation can alleviate the predicted risk of cut-out failure. Screws purchasing in the calcar and posterior humeral head regions may be prioritized. Although requiring clinical corroborations, these findings may explain the controversial results of previous clinical studies not controlling the choices of screw augmentation.

18.
Clin Biomech (Bristol, Avon) ; 80: 105201, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-33158573

RESUMEN

BACKGROUND: Screws are the most commonly inserted orthopaedic implants. However, several variables related to screw insertion and tightening have not been evaluated. This study aimed firstly to assess the effect of insertion variables on screw tightness, secondly to improve methodologies used by researchers when testing screw insertion techniques and thirdly to assess for any learning or fatigue effects when inserting screws. METHODS: Two surgeons tightened a total of 2280 non-locking, 3.5 mm cortical screws, with 120 screws inserted to what they felt to be optimum tightness whilst varying each of the following factors: different screwdrivers for measuring torque, screwdriver orientation, gloves usage, dominant/non-dominant hand usage, awareness to the applied torque (blinded, unblinded and re-blinded), four bone densities and seven cortical thicknesses. Screws were tightened to failure to determine stripping torque, which was used to calculate screw tightness - ratio between stopping and stripping torque. FINDINGS: Screw tightness increased with glove usage, being blinded to the applied torque and with denser artificial bone and with thinner cortices. Considering all the insertions performed, the two surgeons stopped tightening screws at difference values of tightness ((77% versus 66% (p < 0.001)). A learning effect was observed with some parameters including sterile gloves usage and non-dominant hand application. INTERPRETATION: Different insertion conditions frequently changed screw tightness for both surgeons. Given the influence of screw tightness on fixation stability, the variables investigated within this study should be carefully reported and controlled when performing biomechanical testing alongside practicing screw insertion under different conditions during surgical training.


Asunto(s)
Tornillos Óseos , Fijación Interna de Fracturas/instrumentación , Fenómenos Mecánicos , Fenómenos Biomecánicos , Humanos , Torque
19.
EFORT Open Rev ; 5(1): 26-36, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-32071771

RESUMEN

Billions of screws are inserted by surgeons each year, making them the most commonly inserted implant. When using non-locking screws, insertion technique is decided by the surgeon, including how much to tighten each screw. The aims of this study were to assess, through a systematic review, the screw tightness and rate of material stripping produced by surgeons and the effect of different variables related to screw insertion.Twelve studies were included, with 260 surgeons inserting a total of 2793 screws; an average of 11 screws each, although only 1510 screws have been inserted by 145 surgeons where tightness was measured - average tightness was 78±10% for cortical (n = 1079) and 80±6% for cancellous screw insertions (n = 431).An average of 26% of all inserted screws irreparably damaged and stripped screw holes, reducing the construct pullout strength. Furthermore, awareness of bone stripping is very poor, meaning that screws must be considerably overtightened before a surgeon will typically detect it.Variation between individual surgeons' ability to optimally insert screws was seen, with some surgeons stripping more than 90% of samples and others hardly any. Contradictory findings were seen for the relationship between the tightness achieved and bone density.The optimum tightness for screws remains unknown, thus subjectively chosen screw tightness, which varies greatly, remains without an established target to generate the best possible construct for any given situation. Work is needed to establish these targets, and to develop methods to accurately and repeatably achieve them. Cite this article: EFORT Open Rev 2020;5:26-36. DOI: 10.1302/2058-5241.5.180066.

20.
Mol Imaging Biol ; 22(3): 752-763, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-31429050

RESUMEN

PURPOSE: This study was undertaken to evaluate radiation dosimetry for the prostate-specific membrane antigen targeted [68Ga]Ga-P16-093 radiopharmaceutical, and to initially assess agent performance in positron emission tomography (PET) detection of the site of disease in prostate cancer patients presenting with biochemical recurrence. PROCEDURES: Under IND 133,222 and an IRB-approved research protocol, we evaluated the biodistribution and pharmacokinetics of [68Ga]Ga-P16-093 with serial PET imaging following intravenous administration to ten prostate cancer patients with biochemical recurrence. The recruited subjects were all patients in whom a recent [68Ga]Ga-PSMA-11 PET/X-ray computed tomography (CT) exam had been independently performed under IND 131,806 to assist in decision-making with regard to their clinical care. Voided urine was collected from each subject at ~ 60 min and ~ 140 min post-[68Ga]Ga-P16-093 injection and assayed for Ga-68 content. Following image segmentation to extract tissue time-activity curves and corresponding cumulated activity values, radiation dosimetry estimates were calculated using IDAC Dose 2.1. The prior [68Ga]Ga-PSMA-11 PET/CT exam (whole-body PET imaging at 60 min post-injection, performed with contrast-enhanced diagnostic CT) served as a reference scan for comparison to the [68Ga]Ga-P16-093 findings. RESULTS: [68Ga]Ga-P16-093 PET images at 60 min post-injection provided diagnostic information that appeared equivalent to the subject's prior [68Ga]Ga-PSMA-11 scan. With both radiopharmaceuticals, sites of tumor recurrence were found in eight of the ten patients, identifying 16 lesions. The site of recurrence was not detected with either agent for the other two subjects. Bladder activity was consistently lower with [68Ga]Ga-P16-093 than [68Ga]Ga-PSMA-11. The kidneys, spleen, salivary glands, and liver receive the highest radiation exposure from [68Ga]Ga-P16-093, with estimated doses of 1.7 × 10-1, 6.7 × 10-2, 6.5 × 10-2, and 5.6 × 10-2 mGy/MBq, respectively. The corresponding effective dose from [68Ga]Ga-P16-093 is 2.3 × 10-2 mSv/MBq. CONCLUSIONS: [68Ga]Ga-P16-093 provided diagnostic information that appeared equivalent to [68Ga]Ga-PSMA-11 in this limited series of ten prostate cancer patients presenting with biochemical recurrence, with the kidneys found to be the critical organ. Diminished tracer appearance in the urine represents a potential advantage of [68Ga]Ga-P16-093 over [68Ga]Ga-PSMA-11 for detection of lesions in the pelvis.


Asunto(s)
Antígenos de Superficie/metabolismo , Ácido Edético/análogos & derivados , Glutamato Carboxipeptidasa II/metabolismo , Recurrencia Local de Neoplasia/diagnóstico por imagen , Oligopéptidos/farmacocinética , Tomografía de Emisión de Positrones/métodos , Neoplasias de la Próstata/diagnóstico por imagen , Radiofármacos/farmacocinética , Anciano , Ácido Edético/química , Ácido Edético/farmacocinética , Isótopos de Galio , Radioisótopos de Galio , Humanos , Masculino , Persona de Mediana Edad , Recurrencia Local de Neoplasia/metabolismo , Recurrencia Local de Neoplasia/patología , Oligopéptidos/química , Neoplasias de la Próstata/metabolismo , Neoplasias de la Próstata/patología , Radiometría , Radiofármacos/química , Distribución Tisular
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA