1.
Sensors (Basel) ; 22(6)2022 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-35336429

RESUMEN

The interruption of rehabilitation activities caused by the COVID-19 lockdown has significant health negative consequences for the population with physical disabilities. Thus, measuring the range of motion (ROM) using remotely taken photographs, which are then sent to specialists for formal assessment, has been recommended. Currently, low-cost Kinect motion capture sensors with a natural user interface are the most feasible implementations for upper limb motion analysis. An active range of motion (AROM) measuring system based on a Kinect v2 sensor for upper limb motion analysis using Fugl-Meyer Assessment (FMA) scoring is described in this paper. Two test groups of children, each having eighteen participants, were analyzed in the experimental stage, where upper limbs' AROM and motor performance were assessed using FMA. Participants in the control group (mean age of 7.83 ± 2.54 years) had no cognitive impairment or upper limb musculoskeletal problems. The study test group comprised children aged 8.28 ± 2.32 years with spastic hemiparesis. A total of 30 samples of elbow flexion and 30 samples of shoulder abduction of both limbs for each participant were analyzed using the Kinect v2 sensor at 30 Hz. In both upper limbs, no significant differences (p < 0.05) in the measured angles and FMA assessments were observed between those obtained using the described Kinect v2-based system and those obtained directly using a universal goniometer. The measurement error achieved by the proposed system was less than ±1° compared to the specialist's measurements. According to the obtained results, the developed measuring system is a good alternative and an effective tool for FMA assessment of AROM and motor performance of upper limbs, while avoiding direct contact in both healthy children and children with spastic hemiparesis.


Asunto(s)
COVID-19 , COVID-19/diagnóstico , Niño , Preescolar , Control de Enfermedades Transmisibles , Hemiplejía , Humanos , Rango del Movimiento Articular , Extremidad Superior
2.
Sensors (Basel) ; 21(23)2021 Nov 26.
Artículo en Inglés | MEDLINE | ID: mdl-34883885

RESUMEN

Quantifying the quality of upper limb movements is fundamental to the therapeutic process of patients with cerebral palsy (CP). Several clinical methods are currently available to assess the upper limb range of motion (ROM) in children with CP. This paper focuses on identifying and describing available techniques for the quantitative assessment of the upper limb active range of motion (AROM) and kinematics in children with CP. Following the screening and exclusion of articles that did not meet the selection criteria, we analyzed 14 studies involving objective upper extremity assessments of the AROM and kinematics using optoelectronic devices, wearable sensors, and low-cost Kinect sensors in children with CP aged 4-18 years. An increase in the motor function of the upper extremity and an improvement in most of the daily tasks reviewed were reported. In the population of this study, the potential of wearable sensors and the Kinect sensor natural user interface as complementary devices for the quantitative evaluation of the upper extremity was evident. The Kinect sensor is a clinical assessment tool with a unique markerless motion capture system. Few authors had described the kinematic models and algorithms used to estimate their kinematic analysis in detail. However, the kinematic models in these studies varied from 4 to 10 segments. In addition, few authors had followed the joint assessment recommendations proposed by the International Society of Biomechanics (ISB). This review showed that three-dimensional analysis systems were used primarily for monitoring and evaluating spatiotemporal variables and kinematic parameters of upper limb movements. The results indicated that optoelectronic devices were the most commonly used systems. The joint assessment recommendations proposed by the ISB should be used because they are approved standards for human kinematic assessments. This review was registered in the PROSPERO database (CRD42021257211).


Asunto(s)
Parálisis Cerebral , Fenómenos Biomecánicos , Parálisis Cerebral/diagnóstico , Niño , Humanos , Movimiento , Rango del Movimiento Articular , Extremidad Superior