Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Heart Vessels ; 35(12): 1735-1745, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32591894

RESUMEN

Permanent pacemaker implantation (PPI) is a widely recognized complication associated with TAVI (incidence up to 20%). Smaller registries have identified several variables associated with PPI. The objective was to validate patient- and transcatheter aortic valve implantation (TAVI)-related procedural variables associated with PPI. We performed a retrospective analysis of patients from six European centers undergoing TAVI with the Edwards SAPIEN 3 prosthesis. Baseline variables and pre-procedural ECG characteristics and CT-scans were taken into account. Data for 1745 patients were collected; 191 (10.9%) required PPI after TAVI. The baseline variables pulmonary hypertension (OR 1.64; 95% CI 1.01-2.59), QRS duration > 117 ms (OR 2.58; 95% CI 1.73-3.84), right bundle branch block (RBBB; OR 5.14; 95% CI 3.39-7.72), left anterior hemi block (OR 1.92; 95% CI 1.19-3.02) and first-degree atrioventricular block (AVB, OR 1.63; 95%CI 1.05-2.46) were significantly associated with PPI. RBBB (OR 8.11; 95% CI 3.19-21.86) and first-degree AVB (OR 2.39; 95% CI 1.18-4.66) remained significantly associated in a multivariate analysis. Procedure-related variables included access site (TF; OR 1.97; 95% CI 1.07-4.05), implanted valve size (29 mm; OR 1.88; 95% CI 1.35-2.59), mean TAVI valve implantation depth below the annulus > 30% (OR 3.75; 95% CI 2.01-6.98). Patients receiving PPI had longer ICU stays and later discharges. Acute kidney injury stage 2/3 was more common in patients with PPI until discharge (15.2 vs. 3.1%; p = 0.007), but was not statistically significant thereafter. Further differences in outcomes at 30 days did not reach significance. The data will aid pre- and post-procedural patient management and prevent adverse long-term outcomes.Clinical Trial: NCT03497611.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Valvuloplastia con Balón/efectos adversos , Estimulación Cardíaca Artificial , Bloqueo Cardíaco/terapia , Frecuencia Cardíaca , Prótesis Valvulares Cardíacas , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Europa (Continente) , Femenino , Bloqueo Cardíaco/diagnóstico , Bloqueo Cardíaco/etiología , Bloqueo Cardíaco/fisiopatología , Humanos , Masculino , Sistema de Registros , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA