Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Europace ; 20(6): 935-942, 2018 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-28444228

RESUMEN

Aims: Outcome of persistent atrial fibrillation (AF) ablation remains suboptimal. Techniques employed to reduce arrhythmia recurrence rate are more likely to be embraced if cost-effectiveness can be demonstrated. A single-centre observational study assessed whether use of general anaesthesia (GA) in persistent AF ablation improved outcome and was cost-effective. Methods and results: Two hundred and ninety two patients undergoing first ablation procedures for persistent AF under conscious sedation or GA were followed. End points were freedom from listing for repeat ablation at 18 months and freedom from recurrence of atrial arrhythmia at 1 year. Freedom from atrial arrhythmia was higher in patients who underwent ablation under GA rather than sedation (63.9% vs. 42.3%, hazard ratio (HR) 1.87, 95% confidence interval (CI): 1.23-2.86, P = 0.002). Significantly fewer GA patients were listed for repeat procedures (29.2% vs. 42.7%, HR 1.62, 95% CI: 1.01-2.60, P = 0.044). Despite GA procedures costing slightly more, a saving of £177 can be made per patient in our centre for a maximum of two procedures if all persistent AF ablations are performed under GA. Conclusions: In patients with persistent AF, it is both clinical and economically more effective to perform ablation under GA rather than sedation.


Asunto(s)
Anestesia General/métodos , Fibrilación Atrial , Ablación por Catéter , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/economía , Ablación por Catéter/métodos , Análisis Costo-Beneficio/métodos , Análisis Costo-Beneficio/estadística & datos numéricos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Evaluación de Procesos y Resultados en Atención de Salud , Mejoramiento de la Calidad , Reoperación/métodos , Reoperación/estadística & datos numéricos , Factores de Riesgo , Prevención Secundaria/métodos , Reino Unido
2.
Europace ; 18(6): 888-96, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-26498160

RESUMEN

AIMS: The targeted genetic screening of Sudden Arrhythmic Death Syndrome (SADS) probands in a molecular autopsy has a diagnostic yield of up to 35%. Exome sequencing has the potential to improve this yield. The primary aim of this study is to examine the feasibility and diagnostic utility of targeted exome screening in SADS victims, utilizing familial clinical screening whenever possible. METHODS AND RESULTS: To determine the feasibility and diagnostic yield of targeted exome sequencing deoxyribonucleic acid (DNA) was isolated from 59 SADS victims (mean age 25 years, range 1-51 years). Targeted exome sequencing of 135 genes associated with cardiomyopathies and ion channelopathies was performed on the Illumina HiSeq2000 platform. Non-synonymous, loss-of-function, and splice-site variants with a minor allele frequency <0.02% in the NHLBI exome sequencing project and an internal set of control exomes were prioritized for analysis followed by <0.5% frequency threshold secondary analysis. First-degree relatives were offered clinical screening for inherited cardiac conditions. Seven probands (12%) carried very rare (<0.02%) or novel non-sense candidate mutations and 10 probands (17%) had previously published rare (0.02-0.5%) candidate mutations-a total yield of 29%. Co-segregation fully confirmed two private SCN5A Na channel mutations. Variants of unknown significance were detected in a further 34% of probands. CONCLUSION: Molecular autopsy using targeted exome sequencing has a relatively low diagnostic yield of very rare potentially disease causing mutations. Candidate pathogenic variants with a higher frequency in control populations are relatively common and should be interpreted with caution.


Asunto(s)
Síndrome de Brugada/diagnóstico , Síndrome de Brugada/genética , Exoma/genética , Síndrome de QT Prolongado/diagnóstico , Síndrome de QT Prolongado/genética , Adolescente , Adulto , Autopsia , Estudios de Casos y Controles , Niño , Preescolar , Estudios de Cohortes , Muerte Súbita Cardíaca/prevención & control , Femenino , Frecuencia de los Genes , Predisposición Genética a la Enfermedad , Pruebas Genéticas , Humanos , Lactante , Masculino , Persona de Mediana Edad , Mutación , Canal de Sodio Activado por Voltaje NAV1.5/genética , Linaje , Análisis de Secuencia de ADN , Reino Unido , Adulto Joven
3.
Eur Heart J ; 36(28): 1812-21, 2015 Jul 21.
Artículo en Inglés | MEDLINE | ID: mdl-25920401

RESUMEN

AIMS: Pulmonary vein isolation (PVI) is the cornerstone of catheter ablation of atrial fibrillation (AF). The intervenous ridge (IVR) may be incorporated into ablation strategies to achieve PVI; however, randomized trials are lacking. We performed a randomized multi-centre international study to compare the outcomes of (i) circumferential antral PVI (CPVI) alone (minimal) vs. (ii) CPVI with IVR ablation to achieve individual PVI (maximal). METHODS AND RESULTS: Two hundred and thirty-four patients with paroxysmal AF underwent CPVI and were randomized to a minimal or maximal ablation strategy. The primary outcome of recurrent atrial arrhythmia was assessed with 7-day Holter monitoring at 6 and 12 months. PVI was achieved in all patients. Radiofrequency ablation time was longer in the maximal group (46.6 ± 14.6 vs. 41.5 ± 13.1 min; P < 0.01), with no significant differences in procedural or fluoroscopy times. At mean follow-up of 17 ± 8 months, there was no difference in freedom from AF after a single procedure between a minimal (70%) and maximal ablation strategy (62%; P = 0.25). In the minimal group, ablation was required on the IVR to achieve electrical isolation in 44%, and was associated with a significant reduction in freedom from AF (57%) compared with the minimal group without IVR ablation (80%; P < 0.01). CONCLUSION: There was no statistically significant difference in freedom from AF between a minimal and maximal ablation strategy. Despite attempts to achieve PVI with antral ablation, IVR ablation is commonly required. Patients in whom antral isolation can be achieved without IVR ablation have higher long-term freedom from AF (the Minimax study; ACTRN12610000863033).


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Antiarrítmicos/uso terapéutico , Fibrilación Atrial/tratamiento farmacológico , Electrocardiografía Ambulatoria , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Venas Pulmonares/cirugía , Recurrencia , Reoperación , Resultado del Tratamiento
4.
N Engl J Med ; 363(1): 36-44, 2010 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-20463331

RESUMEN

BACKGROUND: Implantable cardioverter-defibrillators (ICDs) prevent sudden death from cardiac causes in selected patients but require the use of transvenous lead systems. To eliminate the need for venous access, we designed and tested an entirely subcutaneous ICD system. METHODS: First, we conducted two short-term clinical trials to identify a suitable device configuration and assess energy requirements. We evaluated four subcutaneous ICD configurations in 78 patients who were candidates for ICD implantation and subsequently tested the best configuration in 49 additional patients to determine the subcutaneous defibrillation threshold in comparison with that of the standard transvenous ICD. Then we evaluated the long-term use of subcutaneous ICDs in a pilot study, involving 6 patients, which was followed by a trial involving 55 patients. RESULTS: The best device configuration consisted of a parasternal electrode and a left lateral thoracic pulse generator. This configuration was as effective as a transvenous ICD for terminating induced ventricular fibrillation, albeit with a significantly higher mean (+/-SD) energy requirement (36.6+/-19.8 J vs. 11.1+/-8.5 J). Among patients who received a permanent subcutaneous ICD, ventricular fibrillation was successfully detected in 100% of 137 induced episodes. Induced ventricular fibrillation was converted twice in 58 of 59 patients (98%) with the delivery of 65-J shocks in two consecutive tests. Clinically significant adverse events included two pocket infections and four lead revisions. After a mean of 10+/-1 months, the device had successfully detected and treated all 12 episodes of spontaneous, sustained ventricular tachyarrhythmia. CONCLUSIONS: In small, nonrandomized studies, an entirely subcutaneous ICD consistently detected and converted ventricular fibrillation induced during electrophysiological testing. The device also successfully detected and treated all 12 episodes of spontaneous, sustained ventricular tachyarrhythmia. (ClinicalTrials.gov numbers, NCT00399217 and NCT00853645.)


Asunto(s)
Desfibriladores Implantables , Cardiopatías/terapia , Adulto , Anciano , Anciano de 80 o más Años , Electrocardiografía , Electrodos Implantados , Diseño de Equipo , Femenino , Cardiopatías/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Volumen Sistólico , Adulto Joven
5.
Europace ; 14(10): 1498-505, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-22523376

RESUMEN

AIMS: Cardiac transplantation (CTX) is an effective treatment for end-stage heart disease. Cardiac arrhythmias are increasingly recognized and associated with significant morbidity and mortality. We aim to describe the clinical and electrophysiological characteristics of patients with atrial arrhythmias occurring late after CTX. METHODS AND RESULTS: Sixteen patients with prior CTX who presented with late atrial arrhythmias for electrophysiological studies (EPS) were identified at two cardiac transplant centres. Among 859 patients, 16 (mean age 52 ± 14 years, 11 of 16 were men) patients underwent EPS for atrial arrhythmias presenting 8.6 ± 5.7 years following CTX. Among 16 patients, 14 underwent cardiac alone and 2 included lung transplantation. There were no cases of cardiac rejection. Arrhythmias were due to counterclockwise cavotricuspid-dependent atrial flutter (AFL) in 10 of 16, atrial tachycardia (AT) in 6 (1 patient had AFL and AT), and 1 due to atrioventricular nodal re-entrant tachycardia. Recipient-donor atrial electrical connection was seen in two of six AT and in no cases of AFL. In two cases, a focal AT was mapped to the remnant atrium conducting 2 : 1 or at variable block to the donor atrium. In four cases a focal/micro re-entrant AT originated within the vicinity of the interatrial suture scar. All cases were successfully ablated with radiofrequency energy; however, one case of AFL required a repeat ablation. Patients remained free of arrhythmia at 34 ± 15 months post-ablation. CONCLUSION: Typical AFL and AT are the most frequent supraventricular arrhythmias occurring late following CTX. Focal ATs may originate in low-voltage or border zones immediately adjacent to the atrio-atrial anastomosis. Radiofrequency ablation is an effective treatment strategy with high long-term success.


Asunto(s)
Arritmias Cardíacas/etiología , Arritmias Cardíacas/cirugía , Ablación por Catéter/métodos , Insuficiencia Cardíaca/cirugía , Trasplante de Corazón/efectos adversos , Adulto , Anciano , Electrocardiografía , Técnicas Electrofisiológicas Cardíacas , Femenino , Corazón/fisiología , Humanos , Trasplante de Pulmón , Masculino , Persona de Mediana Edad , Resultado del Tratamiento
6.
Europace ; 13(11): 1660-1, 2011 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-21596720

RESUMEN

We present the unusual association of an atrial tachycardia with Friedreich ataxia. The arrhythmia was initially suspected to be focal in origin; however, use of a three-dimensional mapping system demonstrated that the tachycardia was macro-reentrant. This was subsequently treated successfully by linear ablation.


Asunto(s)
Ecocardiografía , Ataxia de Friedreich/complicaciones , Taquicardia Atrial Ectópica/diagnóstico por imagen , Taquicardia Atrial Ectópica/etiología , Adulto , Ablación por Catéter , Técnicas Electrofisiológicas Cardíacas , Humanos , Masculino , Taquicardia Atrial Ectópica/cirugía , Resultado del Tratamiento , Disfunción Ventricular Izquierda/diagnóstico por imagen
7.
Europace ; 13(6): 845-52, 2011 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-21427090

RESUMEN

AIMS: Left ventricular (LV) lead placement to the most delayed segment offers the greatest potential benefit to cardiac resynchronization therapy (CRT). We assessed the impact of interventricular (VV) optimization on acute changes in cardiac output (CO) in patients with and without LV pacing of the most delayed segment. METHODS AND RESULTS: In 124 patients, the most delayed segment was defined by speckle tracking radial strain and the LV lead position by biplane fluoroscopy. Patients were classified as either a concordant (LV lead at latest site), adjacent (within one segment), or remote (two or more segments away) LV lead. Atrioventricular (AV) and VV delays were optimized by echocardiography. Cardiac output was measured non-invasively and a >20% increase in CO from baseline (intrinsic) defined acute response. Changes in CO in patients with concordant, adjacent, or remote LV leads were recorded following atrioventricular optimization alone (AV OPT) and after combined AV and VV optimization (AV/VV OPT). Compared with AV OPT pacing, AV/VV OPT produced a greater rise in CO (5.45 ± 1.1 vs. 5.76 ± 1.2 L/min, P< 0.001) and higher acute response rates (48.4 vs. 61.3%, P= 0.041). In adjacent patients, compared with AV OPT pacing, AV/VV OPT settings increased the response rate from 36.4 to 63.6% (P= 0.037). VV optimization had no effect on acute response rates in patients with remote (26.7 vs. 33.3%, P = 0.581) or concordant LV leads (65.6 vs. 72.1%, P = 0.438). CONCLUSION: VV optimization overcomes some but not all of the deleterious effects of a suboptimal LV lead position.


Asunto(s)
Bloqueo de Rama/terapia , Terapia de Resincronización Cardíaca/métodos , Insuficiencia Cardíaca/terapia , Ventrículos Cardíacos/fisiopatología , Hemodinámica/fisiología , Disfunción Ventricular Izquierda/terapia , Anciano , Anciano de 80 o más Años , Gasto Cardíaco/fisiología , Dispositivos de Terapia de Resincronización Cardíaca , Ecocardiografía , Electrodos , Femenino , Estudios de Seguimiento , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Resultado del Tratamiento
8.
Pacing Clin Electrophysiol ; 34(11): 1527-36, 2011 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-21797899

RESUMEN

AIMS: Noninvasive cardiac output (CO) measurement (NICOM) is a novel method to assess ventricular function and offers a potential alternative for optimization of cardiac resynchronization therapy (CRT) devices. We compared the effect of NICOM-based optimization to no optimization (empiric settings) on CRT outcomes. METHODS: Two hundred and three patients undergoing CRT were assessed in two consecutive nonrandomized groups; an empiric group (n = 54) was programmed to "out of the box" settings with a fixed AV delay of 120 ms and a VV delay of 0 ms; and the optimization group (n = 149) underwent adjustments of both the AV and VV delays according to the greatest improvement in resting CO. The primary endpoints were improvements in left ventricular (LV) volumes and function from baseline at 6 months. Secondary endpoints were change in New York Heart Association (NYHA) class, quality of life score, and 6-minute walk test (6 MWT) performance. RESULTS: After 6 months of CRT, the optimization group had a better clinical response with lower NYHA class (2.1 ± 0.8 vs 2.4 ± 0.8, P = 0.048) and quality of life scores (35 ± 18 vs 42 ± 20, P = 0.045) but no differences in 6-MWT performance (269 ± 110 vs 277 ± 114 m, P = 0.81). Echocardiographic response was also better in the optimization group with lower LV end systolic volume (108 ± 51 vs 126 ± 60 mL, P = 0.048) and higher ejection fraction (30 ± 7 vs 27 ± 8, P = 0.01) compared to empiric settings. CONCLUSION: Device optimization using noninvasive measures of CO is associated with better clinical and echocardiographic response compared to empiric settings.


Asunto(s)
Gasto Cardíaco , Terapia de Resincronización Cardíaca/métodos , Cardiografía de Impedancia/métodos , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/prevención & control , Disfunción Ventricular Izquierda/diagnóstico , Disfunción Ventricular Izquierda/prevención & control , Anciano , Femenino , Insuficiencia Cardíaca/complicaciones , Humanos , Masculino , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Resultado del Tratamiento , Disfunción Ventricular Izquierda/complicaciones
9.
Pacing Clin Electrophysiol ; 34(4): 467-74, 2011 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-21208234

RESUMEN

INTRODUCTION: Left ventricular (LV) lead placement to the latest contracting area (concordant LV lead) is associated with better response to cardiac resynchronization therapy (CRT) compared to a discordant LV lead. However, the effect of the right ventricular (RV) lead site on CRT response is unclear. We investigated the relationship of the RV and LV lead positions on CRT response. METHODS: In 131 CRT patients, the LV lead was positioned preferentially in a lateral or posterolateral vein and the RV lead to either the RV septum (RVS, n = 55) or RV apex (RVA, n = 76). The latest site of contraction was determined with two-dimensional speckle tracking radial strain imaging and patients had a concordant LV lead position if pacing the latest segment, and discordant if not. Response was defined as ≥15% reduction in LV end systolic volume (LVESV) at 6-month follow-up. RESULTS: There were no significant differences in mean reduction of LVESV at follow-up (RVS vs RVA: -23.3 ± 16% vs 22.1 ± 18%, P = 0.70) or rate of responders (58.2% vs 57.9%, P = 0.97) between the two groups. In patients with a concordant LV lead (n = 71), the response rate was significantly higher than those with a discordant lead (76.1% vs 36.7%, P < 0.001). There were no differences in outcomes in patients with a concordant or discordant LV lead according to the RV lead location. CONCLUSION: The extent of LV reverse remodeling following CRT is not related to the RV lead position, but is significantly higher in patients with a concordant LV lead.


Asunto(s)
Dispositivos de Terapia de Resincronización Cardíaca/estadística & datos numéricos , Electrodos Implantados , Insuficiencia Cardíaca/epidemiología , Insuficiencia Cardíaca/prevención & control , Implantación de Prótesis/estadística & datos numéricos , Anciano , Terapia de Resincronización Cardíaca/métodos , Terapia de Resincronización Cardíaca/estadística & datos numéricos , Femenino , Insuficiencia Cardíaca/diagnóstico , Ventrículos Cardíacos , Humanos , Masculino , Prevalencia , Implantación de Prótesis/métodos , Resultado del Tratamiento , Reino Unido/epidemiología
10.
Europace ; 11(12): 1666-74, 2009 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-19910316

RESUMEN

AIMS: Non-invasive cardiac output monitoring (NICOM) based on bio-reactance offers a portable method to assess ventricular function. Optimization of cardiac resynchronization therapy (CRT) by echocardiography is labour-intensive. We compared the ability of NICOM and echocardiography to facilitate optimum CRT device programming. METHODS AND RESULTS: Forty-seven patients in sinus rhythm were evaluated within 14 days of CRT implantation. The atrio- (AV) and interventricular (VV) delay intervals were incrementally adjusted and at each setting, NICOM and echocardiographic data were recorded. Left ventricular (LV) volumes and function were assessed by echocardiography at baseline and 3 months. Response to CRT was defined as a reduction in LV end-systolic volume (LVESV) by >15%. In all patients, cardiac output (CO) increased significantly at optimized settings compared with baseline (5.66 +/- 1.4 vs. 4.35 +/- 1.1 L/min, P < 0.001). A 20% increase in acute CO following CRT predicted LVESV reduction of >15% with a sensitivity of 81% and specificity of 92% (AUC 0.86). The optimum AV delay determined by NICOM was confirmed by echocardiography in 40 of 47 patients (85%, r = 0.89, P < 0.01) and for VV delay in 39 of 47 patients (83%, r = 0.89, P < 0.01). CONCLUSION: Non-invasive cardiac output monitoring is a simple, reliable, and portable alternative to echocardiography to program CRT devices.


Asunto(s)
Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/prevención & control , Gasto Cardíaco , Pletismografía de Impedancia/métodos , Anciano , Impedancia Eléctrica , Femenino , Humanos , Masculino , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Resultado del Tratamiento
11.
J Atr Fibrillation ; 10(5): 1607, 2018 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-29988240

RESUMEN

AIM: There is controversy and sparse data on whether substrate based techniques in addition to pulmonary vein isolation (PVI) confer benefit in the catheter ablation of persistent atrial fibrillation (AF), especially if long standing. We performed an observational study to assess whether substrate based ablation improved freedom from atrial arrhythmia. METHODS: A total of 286 patients undergoing first ablation procedures for persistent AF with PVI only(n = 79), PVI plus linear ablation(n = 85), or PVI plus complex fractionated electrogram (CFAE) and linear ablation(n = 107) were followed. Primary end point was freedom from atrial arrhythmia at one year. RESULTS: Mean duration of pre-procedure time in AF was 28+/-27 months.There were no differences in baseline characteristics between groups except a higher proportion of patients with a severely dilated LA in those receiving PVI+CFAEs+lines. Freedom from atrial arrhythmia was higher with a PVI+CFAE+lines strategy then for PVI alone (HR 1.56, 95% CI: 1.04-2.34, p=0.032) but was not higher with PVI+lines. Benefit of substrate modification was conferred for preprocedure times in AF of over 30 months. The occurrence of atrial tachycardia was higher when lines were added to the ablation strategy (HR 0.08, 95% CI: 0.01-0.59, p=0.014). Freedom from atrial arrhythmia at 1 year was higher with lower patient age, use of general anaesthetic (GA), normal or mildly dilated left atrium and decreasing time in AF. CONCLUSIONS: In patients with long standing persistent AF of over 30 months duration,CFAE ablation resulted in improved freedom from atrial arrhythmia. Increased freedom from atrial arrhythmia occurs in patients who are younger and have smaller atria, and with GA procedures. Linear ablation did not improve outcome and resulted in a higher incidence of atrial tachycardia.

12.
J Am Coll Cardiol ; 45(9): 1488-93, 2005 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-15862424

RESUMEN

OBJECTIVES: The goal of this study was to characterize the electrocardiographic and electrophysiologic features and frequency of focal atrial tachycardia (AT) originating from the coronary sinus ostium (CS). BACKGROUND: The ostium of the coronary sinus has been described as a site of origin of AT, but detailed characterization of these tachycardias is limited. METHODS: Thirteen patients (6.7%) of 193 undergoing radiofrequency ablation (RFA) for focal AT are reported. Endocardial activation maps (EAM) were recorded from catheters at the CS (10 pole), crista terminalis (20 pole), and His positions. The P waves were classified negative, positive, isoelectric, or biphasic. RESULTS: The mean age was 41 +/- 6 years, seven female patients, with symptoms for 8 +/- 3 years. Tachycardia was induced by programmed extra-stimuli in eight patients, was spontaneous in three patients, and in response to isoproterenol in two patients. These foci had a characteristic P-wave morphology. At the CS ostium, the P-wave was deeply negative in all inferior leads, negative or isoelectric becoming positive in lead V(1), then progressively negative across the precordium. Lead aVL was positive in all patients. Earliest EAM activity occurred at the proximal CS at 20 +/- 3 ms ahead of P-wave. Mean activation time at the successful RFA site = -36 +/- 8 ms; RFA was acutely successful in 11 of 13 patients. Long-term success was achieved in 11 of 11 over a median follow-up of 25 +/- 4 months. CONCLUSIONS: The CS ostium is an uncommon site of origin for focal AT (6.7%). It can be suspected as a potential anatomic site of AT origin from the characteristic P-wave and activation timing. Long-term success was achieved with focal ablation in the majority of patients.


Asunto(s)
Ablación por Catéter , Taquicardia Atrial Ectópica/cirugía , Adolescente , Adulto , Anciano , Electrocardiografía , Técnicas Electrofisiológicas Cardíacas , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Taquicardia Atrial Ectópica/diagnóstico por imagen , Taquicardia Atrial Ectópica/fisiopatología , Resultado del Tratamiento , Ultrasonografía
13.
Circulation ; 109(11): 1434-9, 2004 Mar 23.
Artículo en Inglés | MEDLINE | ID: mdl-15023893

RESUMEN

BACKGROUND: Episodes of atrial fibrillation (AF) are known to cause both a rapid reduction in atrial refractoriness (atrial electrical remodeling) and a more delayed increase in AF stability thought to be due to a so-called "second factor." The aim of this study was to quantify the effects and time course of such a factor on AF stability in the chronic goat model. METHODS AND RESULTS: AF was maintained in 6 goats by burst atrial pacing for 3 consecutive 4-week periods separated a mean of 6+/-2.1 days of sinus rhythm. Six days of sinus rhythm was just sufficient for refractoriness changes to reverse fully in all goats. Atrial effective refractory period, AF inducibility, and duration of individual episodes of AF were assessed at regular intervals. There was a progressive reduction from month 1 to 2 to 3 in the mean duration of burst pacing required to induce individual episodes of AF of 60 seconds (178+/-251, 110+/-102, and 21+/-30 hours), 1 hour (229+/-224, 136+/-104, and 68+/-51 hours), and 24 hours (277+/-218, 192+/-190, and 102+/-75 hours; P<0.03). The frequency with which AF was induced during extrastimulus pacing increased progressively from 16.7% in month 1 to 31.7% in month 2 and 46.9% in month 3 (P<0.001). CONCLUSIONS: Sequential 4-week periods of atrial fibrillation result in a progressive increase in AF stability independent of baseline atrial refractory period. This finding suggests the presence of a second factor in the self-perpetuation of AF with a time course comparable to that of AF-induced ultrastructural changes in the atria.


Asunto(s)
Fibrilación Atrial/fisiopatología , Animales , Fibrilación Atrial/patología , Estimulación Cardíaca Artificial , Progresión de la Enfermedad , Femenino , Cabras , Atrios Cardíacos/fisiopatología , Atrios Cardíacos/ultraestructura , Sistema de Conducción Cardíaco/fisiopatología , Modelos Animales , Modelos Cardiovasculares , Periodicidad , Recurrencia , Especificidad de la Especie
14.
Circulation ; 108(16): 1968-75, 2003 Oct 21.
Artículo en Inglés | MEDLINE | ID: mdl-14557361

RESUMEN

BACKGROUND: The objective of this study was to describe the electrophysiological characteristics, anatomic distribution, and long-term outcome after focal ablation (RFA) of pulmonary vein (PV) atrial tachycardia (AT). Both atrial fibrillation (AF) and AT may be due to a rapidly firing focus in the PVs. Whether these represent two aspects of the same process is unknown. METHODS AND RESULTS: Twenty-seven patients with 28 PV(16%) ATs of a consecutive series of 172 undergoing RFA for focal AT are reported. The mean age was 39+/-16 years, with symptoms for 9+/-14 years resistant to 1.7+/-0.8 medications. AT occurred spontaneously or with isoproterenol in all patients and was not inducible with PES in any. The distribution of PV ATs was right superior PV, 11; left superior PV, 11; left inferior PV, 5; and right inferior PV, 1; 26of 28 foci (93%) were ostial. RFA was successful in 28 of 28 PV ATs acutely. RFA was focal in 25 of 28, with PV isolation of a single target vein in 3. There were 4 recurrences at a mean of 3.3 months. Repeat RFA was performed in all 4 and successful in 3 of 4. All but one recurrence occurred from the same site. Long-term success was achieved in 26 of 27 (96%) patients at mean follow-up of 25+/-22 months. No patients have had subsequent development of AF or AT from a different site. CONCLUSIONS: PV AT has a distribution similar to PV AF, with a propensity to upper veins. However, the majority of foci are ostial, and only a small percentage occur from deep in the PV. Focal RFA is associated with high long-term success, with freedom from both AT from other sites and from AF. PV AT is a localized process and therefore may be different from PV AF.


Asunto(s)
Ablación por Catéter , Electrocardiografía , Venas Pulmonares/fisiopatología , Taquicardia/diagnóstico , Taquicardia/fisiopatología , Adolescente , Adulto , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Niño , Técnicas Electrofisiológicas Cardíacas , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Recurrencia , Reoperación , Taquicardia/cirugía , Resultado del Tratamiento
15.
J Am Coll Cardiol ; 44(1): 109-16, 2004 Jul 07.
Artículo en Inglés | MEDLINE | ID: mdl-15234418

RESUMEN

OBJECTIVES: The purpose of this study was to characterize the pattern of atrial remodeling seen with human aging. BACKGROUND: Atrial fibrillation (AF) occurs in 3% to 4% of the population over 65 years of age. It is associated with thromboembolic complications, worsening heart failure, and increased mortality, yet the electrical and structural remodeling that occurs with human aging remains unknown. METHODS: Thirteen patients (66.4 +/- 1.7 years) > or =60 years (group A), 13 patients (50 +/- 2.1 years) age 31 to 59 years (group B), and 15 patients (24.7 +/- 1.0 years) < or =30 years (group C) underwent conventional electrophysiologic studies and electroanatomic mapping. We measured atrial refractoriness (ERP) at the distal coronary sinus (CS); low and high lateral right atrium (LRA) and the high septal right atrium at 600, 500, and 400 ms; maximum corrected sinus node recovery time (CSNRT); P-wave duration (PWD); conduction time (CT) along the CS and LRA; and discrete double potentials (DP) along the crista. RESULTS: Aging was associated with an increase in atrial ERP, prolonged CT along the CS, increased PWD and CSNRT. There was no significant change in dispersion of refractoriness or rate adaptation. Electroanatomic mapping revealed diffuse areas of low voltage with regional conduction slowing. Both techniques demonstrated a greater number of DPs and fractionated signals along the crista terminalis with aging. CONCLUSIONS: Aging is associated with regional conduction slowing, anatomically determined conduction delay at the crista, and structural changes that include areas of low voltage. In addition, impairment of sinus node function and an increase in atrial ERP occurred with aging. This electrical and structural remodeling may explain the increased propensity to AF with aging.


Asunto(s)
Envejecimiento/fisiología , Mapeo del Potencial de Superficie Corporal , Técnicas Electrofisiológicas Cardíacas , Adulto , Factores de Edad , Anciano , Fibrilación Atrial/fisiopatología , Función Atrial/fisiología , Atrios Cardíacos/fisiopatología , Sistema de Conducción Cardíaco/anatomía & histología , Sistema de Conducción Cardíaco/fisiopatología , Humanos , Persona de Mediana Edad , Estudios Prospectivos , Estadística como Asunto
16.
Curr Cardiol Rev ; 11(2): 103-10, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25308814

RESUMEN

Focal atrial tachycardias arise preferentially from specific locations within the atria. Careful analysis of the P wave can provide useful information about the chamber and likely site of origin within that chamber. Macro-reentrant atrial flutter also tends to occur over a limited number of potential circuits. In this case, the ECG usually gives a guide to the chamber of origin, but unless it shows a specific morphology it is less useful in delineating the circuit involved. Nonetheless, prior knowledge of the likely chamber of origin helps to plan the ablation strategy.


Asunto(s)
Aleteo Atrial/fisiopatología , Taquicardia/fisiopatología , Algoritmos , Ablación por Catéter , Electrocardiografía , Atrios Cardíacos/fisiopatología , Humanos
19.
Eur Heart J Cardiovasc Imaging ; 15(5): 500-8, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24145456

RESUMEN

AIMS: Functional mitral regurgitation (FMR) is a consequence of mitral annular enlargement, leaflet tethering and reduced co-aptation. The importance of the left atrium (LA) as a cause of mitral regurgitation (MR) is less clear. We applied a co-aptation index using three-dimensional (3D) transoesophageal echocardiography to FMR and MR secondary to LA dilatation (atrial mitral regurgitation, AMR). METHODS AND RESULTS: Seventy-two patients underwent comprehensive 3D echo studies: FMR (n = 19); AMR (n = 33); and 20 controls. We recorded: LV size and function; LA dimensions; mitral annular area (MVA); and leaflet area in early and late systole. MVA fractional change was defined: (MVA late systole - MVA early systole)/MVA late systole × 100%; the co-aptation index was defined: (leaflet area early systole - leaflet area late systole)/leaflet area early systole × 100%. Despite normal LV size and function in AMR, MVA was increased similarly to FMR (AMR 12.86 cm(2) vs. FMR 12.33 cm(2), P = ns; both P < 0.01 vs. controls 8.83 cm(2)), and MVA fractional change similarly reduced (AMR 5.1% vs. FMR 6.3%; P = ns; both P < 0.001 vs. controls 14.6%). The co-aptation index was reduced in both MR groups (FMR 6.6% vs. AMR 7.0%, P = ns; both P < 0.001 vs. controls 19.6%). After multivariate analysis, the co-aptation index (χ(2) = 41.2) and MVA fractional change (χ(2) = 22.1) remained the strongest predictors of MR (both P < 0.001 for the model). A co-aptation index of ≤13% was 96% sensitive and 90% specific for the presence of MR. CONCLUSION: LA dilatation leads to MVA enlargement, reduced leaflet co-aptation and MR even without LV dilatation. A co-aptation index describes this in vivo. This work provides insights into the mechanism of AMR.


Asunto(s)
Ecocardiografía Tridimensional , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/fisiopatología , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/fisiopatología , Anciano , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/fisiopatología , Estudios de Casos y Controles , Ecocardiografía Transesofágica , Femenino , Humanos , Interpretación de Imagen Asistida por Computador , Masculino , Persona de Mediana Edad
20.
Heart ; 100(10): 794-9, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24691411

RESUMEN

OBJECTIVE: Studies have shown beneficial effects of cardiac resynchronisation therapy (CRT) on mortality among patients with heart failure. However the incremental benefits in survival from CRT with a defibrillator (CRT-D) are unclear. The choice of appropriate device remains unanswered. METHOD: This is a single-centre observational study in a tertiary cardiac centre. Patients (n=500) implanted with a CRT device with pacing alone (CRT-P) (n=354) and CRT-D (n=146) were followed for at least 2 years (mean 29 months, SD 14 months). The primary end point was all-cause mortality. RESULTS: A total of 116 deaths (23.2%) were recorded: 88 (24.8%) and 28 (19.2%), in the CRT-P and CRT-D groups, respectively. At 1 year there was a trend favouring CRT-D (HR 0.54, 95% CI 0.27 to 1.07, p=0.08) but this was attenuated by the 2nd year and became insignificant at the end of follow-up (HR 0.76, 95% CI 0.50 to 1.170, p=0.21). There was no survival benefit from having an internal cardioverter-defibrillator if patients were deemed non-responders to CRT. 27% of the CRT-P patients with ischaemic cardiomyopathy met indications for potential internal cardioverter-defibrillator implantation for primary prevention. These were older patients with poorer baseline function in comparison with CRT-D patients with devices for primary prevention. Once these differences were adjusted for, there was no difference in outcome between the groups. CONCLUSIONS: CRT-D did not offer additional survival advantage over CRT-P at longer-term follow-up, as the clinical benefit of a defibrillator attenuated with time. Further work is needed to define which subset of patients benefit from CRT-D.


Asunto(s)
Terapia de Resincronización Cardíaca/métodos , Desfibriladores Implantables , Insuficiencia Cardíaca/terapia , Marcapaso Artificial , Función Ventricular Izquierda/fisiología , Anciano , Femenino , Estudios de Seguimiento , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/fisiopatología , Humanos , Masculino , Estudios Retrospectivos , Tasa de Supervivencia/tendencias , Factores de Tiempo , Resultado del Tratamiento , Reino Unido/epidemiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA