RESUMEN
OBJECTIVE: To evaluate the influence of Bentall procedure on left ventricular function and condition on long-term follow-up. METHODS: Seventy-three consecutive patients who underwent an aortic root and ascending aorta replacement with composite valve button Bentall or flanged Bentall technique, from January 2007 to November 2018, were included in this retrospective study. RESULTS: Postoperative left ventricular ejection fraction significantly increased (52.14±11.38 vs. 56.79±11.36; P=0.041), left ventricular end-systolic diameter significantly reduced (38.25±9.31 mm vs. 34.17±9.15 mm; P=0.027), left ventricular end-diastolic diameter significantly reduced (56.42±9.72 mm vs. 51.58±9.03 mm; P=0.01), and left atrial diameter significantly reduced (45.33±12.77 mm vs. 39.25±12.41 mm; P=0.01), compared to preoperative values. Our long-term survival results are comparable with previous studies in which survival rates in 5 years and 10 years were 83.5% and 69.8%, respectively. In comparing patients according to their New York Heart Association (NYHA) functional class, it was shown that their postoperative functional capacity was improved during the follow-up period (2.1±0.56 vs. 1.2±0.42; P=0.001). CONCLUSION: The Bentall procedure significantly improved the left ventricular systolic function and condition and decreased the left ventricular end-systolic and end-diastolic diameters and the left atrial diameter on long-term follow-up, based on the transthoracic echocardiography. Bentall procedure can be performed with acceptable mortality and morbidity rates on long-term follow-up.
Asunto(s)
Función Ventricular Izquierda , Adulto , Anciano , Válvula Aórtica , Femenino , Estudios de Seguimiento , Implantación de Prótesis de Válvulas Cardíacas , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Volumen Sistólico , Resultado del TratamientoRESUMEN
Abstract Objective: To evaluate the influence of Bentall procedure on left ventricular function and condition on long-term follow-up. Methods: Seventy-three consecutive patients who underwent an aortic root and ascending aorta replacement with composite valve button Bentall or flanged Bentall technique, from January 2007 to November 2018, were included in this retrospective study. Results: Postoperative left ventricular ejection fraction significantly increased (52.14±11.38 vs. 56.79±11.36; P=0.041), left ventricular end-systolic diameter significantly reduced (38.25±9.31 mm vs. 34.17±9.15 mm; P=0.027), left ventricular end-diastolic diameter significantly reduced (56.42±9.72 mm vs. 51.58±9.03 mm; P=0.01), and left atrial diameter significantly reduced (45.33±12.77 mm vs. 39.25±12.41 mm; P=0.01), compared to preoperative values. Our long-term survival results are comparable with previous studies in which survival rates in 5 years and 10 years were 83.5% and 69.8%, respectively. In comparing patients according to their New York Heart Association (NYHA) functional class, it was shown that their postoperative functional capacity was improved during the follow-up period (2.1±0.56 vs. 1.2±0.42; P=0.001). Conclusion: The Bentall procedure significantly improved the left ventricular systolic function and condition and decreased the left ventricular end-systolic and end-diastolic diameters and the left atrial diameter on long-term follow-up, based on the transthoracic echocardiography. Bentall procedure can be performed with acceptable mortality and morbidity rates on long-term follow-up.