Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 89
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Catheter Cardiovasc Interv ; 99(6): 1859-1866, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35362665

RESUMEN

OBJECTIVES: To examine the trends in utilization and outcomes of tricuspid valve (TV) transcatheter edge-to-edge repair (TEER). BACKGROUND: Surgery for isolated tricuspid regurgitation is associated with high morbidity and mortality and is rarely performed. TV TEER is an attractive alternative. METHODS: The Nationwide Readmissions Database was queried using the International Classification of Diseases, 10th Revision, procedure code for TV TEER for years 2016-2019. The main outcomes were trends in utilization and in-hospital all-cause mortality. RESULTS: We identified 918 hospitalizations for TV TEER. There was an uptrend in its utilization from 13 cases in the first quarter of 2016 to 122 cases in the last quarter of 2019 (p trend < 0.001). Concomitant mitral valve (MV) TEER was performed in 42.1% of admissions. The overall in-hospital mortality was 2.1%. Surgical TV replacement was needed in 1.1% of admissions; none of them died during the index hospitalization. Unplanned rehospitalizations were common at 30 days (15.7%); 38.2% of those were due to heart failure. There was no difference in in-hospital mortality between isolated TV TEER and combined MV and TV TEER (1.7% vs. 2.6%, p = 0.359). However, admissions receiving combined procedure had lower length of stay and urgent readmission rate. CONCLUSION: The current study showed that there was an increase in the utilization of TV TEER over 2016-2019 in the United States. TV TEER was associated with low rates of in-hospital mortality; however, the rate of urgent readmission remains high, mainly due to heart failure.


Asunto(s)
Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Insuficiencia de la Válvula Tricúspide , Insuficiencia Cardíaca/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/cirugía , Resultado del Tratamiento , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/complicaciones , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/cirugía , Estados Unidos
2.
J Interv Cardiol ; 2022: 9926423, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35832534

RESUMEN

Objectives: This study was conducted to determine why heart teams recommended transcatheter aortic valve replacement (TAVR) versus surgical AVR (SAVR) for patients at low predicted risk of mortality (PROM) and describe outcomes of these cases. Background: Historically, referral to TAVR was based predominately on the Society of Thoracic Surgeons (STS) risk model's PROM >3%. In selected cases, heart teams had latitude to overrule these scores. The clinical reasons and outcomes for these cases are unclear. Methods: Retrospective data were gathered for all TAVR and SAVR cases conducted by 9 hospitals between 2013 and 2017. Results: Cases included TAVR patients with STS PROM >3% (n = 2,711) and ≤3% (n = 415) and SAVR with STS PROM ≤3% (n = 1,438). Leading reasons for recommending TAVR in the PROM ≤3% group were frailty (57%), hostile chest (22%), severe lung disease (16%), and morbid obesity (13%), and 44% of cases had multiple reasons. Most postoperative and 30-day outcomes were similar between TAVR groups, but the STS PROM ≤3% group had a one-day shorter length of stay (2.5 ± 3.4 vs. 3.5 ± 4.7 days; p ≤ 0.001) and higher one-year survival (91.6% vs. 86.0%, p=0.002). In patients with STS PROM ≤3%, 30-day mortality was higher for TAVR versus SAVR (2.0% vs. 0.6%; p < 0.001). Conclusions: Heart teams recommended TAVR in patients with STS PROM ≤3% primarily due to frailty, hostile chest, severe lung disease, and/or morbid obesity. Similar postoperative outcomes between these patients and those with STS PROM >3% suggest that decisions to overrule STS PROM ≤3% were merited and may have reduced SAVR 30-day mortality rate.


Asunto(s)
Estenosis de la Válvula Aórtica , Fragilidad , Implantación de Prótesis de Válvulas Cardíacas , Enfermedades Pulmonares , Obesidad Mórbida , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Fragilidad/etiología , Fragilidad/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Enfermedades Pulmonares/etiología , Enfermedades Pulmonares/cirugía , Estudios Retrospectivos , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
3.
Catheter Cardiovasc Interv ; 97(4): 691-698, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33400380

RESUMEN

BACKGROUND: There is a paucity of data regarding the outcomes of transcatheter aortic valve replacement (TAVR) versus surgical aortic valve replacement (SAVR) among solid-organ transplant recipients. METHODS: Temporal trends in hospitalizations for aortic valve replacement among solid-organ transplant recipients were determined using the National Inpatient Sample database years 2012-2017. Propensity matching was conducted to compare admissions who underwent TAVR versus SAVR. The primary outcome was in-hospital mortality. RESULTS: The analysis included 1,730 hospitalizations for isolated AVR; 920 (53.2%) underwent TAVR and 810 (46.7%) underwent SAVR. TAVR was increasingly utilized for solid-organ transplant recipients (Ptrend = 0.01), while there was no change in the number of SAVR procedures (Ptrend = 0.20). The predictors of undergoing TAVR for solid-organ transplant recipients included older age, diabetes, and prior coronary artery bypass surgery, while TAVR was less likely utilized in small-sized hospitals. TAVR was associated with lower in-hospital mortality after matching (0.9 vs. 4.7%, odds ratio [OR] 0.19; 95% confidence interval [CI] 0.11-0.35, p < .001) and after multivariable adjustment (OR 0.07; 95% CI 0.03-0.21, p < .001). TAVR was associated with lower rate of acute kidney injury, acute stroke, postoperative bleeding, blood transfusion, vascular complications, discharge to nursing facilities, and shorter median length of hospital stay. There was no difference between both groups in the use of mechanical circulatory support, hemodialysis, arrhythmias, or pacemaker insertion. CONCLUSION: This contemporary observational nationwide analysis showed that TAVR is increasingly performed among solid-organ transplant recipients. Compared with SAVR, TAVR was associated with lower in-hospital mortality, complications, and shorter length of stay.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Trasplante de Órganos , Anciano , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Humanos , Complicaciones Posoperatorias/etiología , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
4.
Catheter Cardiovasc Interv ; 96(3): E369-E376, 2020 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-31794142

RESUMEN

BACKGROUND: Intrathoracic complications (ITC) requiring emergency surgical intervention occur during transcatheter aortic valve replacement (TAVR). OBJECTIVES: Characterize the incidence, outcomes and predictors of ITC in a large cohort of transfemoral (TF) TAVR cases over a 5 year period. METHODS: Retrospective registry and chart review of all nonclinical trial TF-TAVR patients from seven centers within one hospital system from 2012-2016. ITC were defined as cardiac perforation, new or worsening pericardial effusion/tamponade, annular rupture, thoracic aortic injury, aortic valve dislodgement, and coronary artery occlusion. Procedural and 30-day outcomes and 1-year mortality were compared between ITC and no ITC patients. Multivariable logistic regression was used to identify predictors of ITC. RESULTS: Over the study period, 1,581 patients had TF-TAVR and 68 ITC occurred in 46 patients (2.9%). The most common ITCs were pericardial effusion/tamponade (59%), cardiac perforation (33%), and valve dislodgement (33%). ITC rate did not decline over time (rate (95% confidence interval) for 2012 = 0% (0-8.8%), 2013 = 1.3% (0-7.2%), 2014 = 4.4% (2.2-8.0%), 2015 = 3.5% (2.0-5.6%), and 2016 = 2.4% (1.5-3.8%)). ITC patients had worse 1-year survival (ITC: 60.7% (45.1-73.1%), no ITC: 88.7% (87.0-90.3%); p < .001). The majority of ITC patient deaths occurred within the first 30 days. Multivariable models to predict ITC were not successful. CONCLUSIONS: ITC did not decline over time in our cohort. Predictors of ITC could not be identified. While these events are rare, they are associated with worse procedural outcomes and mortality. Heart teams should continue to be prepared for emergency intervention.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Cateterismo Periférico/efectos adversos , Arteria Femoral , Complicaciones Intraoperatorias/cirugía , Esternotomía , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/mortalidad , Cateterismo Periférico/mortalidad , Urgencias Médicas , Femenino , Humanos , Incidencia , Complicaciones Intraoperatorias/diagnóstico , Complicaciones Intraoperatorias/mortalidad , Masculino , Punciones , Sistema de Registros , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Esternotomía/efectos adversos , Esternotomía/mortalidad , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento , Estados Unidos
5.
Catheter Cardiovasc Interv ; 90(5): E111-E121, 2017 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-28145040

RESUMEN

OBJECTIVES: This study aimed to provide a systematic review of device-associated thrombosis (DAT) after left atrial appendage occlusion (LAAO) with the Watchman, Amplatzer Cardiac Plug, and Amulet devices. BACKGROUND: DAT is known as a complication of LAAO but data about its clinical impact is scarce. METHODS: A systematic review of studies evaluating the incidence, treatment and clinical implications of DAT from January 2008 to September 2015 was conducted. RESULTS: A total of 30 studies describing DAT events were included in the analysis. The overall incidence of DAT was 3.9% (82 DAT for 2118 implanted devices). The median time from procedure to diagnosis of DAT was 1.5 months (IQR: 0-2.9). Most cases were diagnosed with transesophageal echocardiogram (TEE). The treatment consisted of low molecular weight heparin (LMWH) in 45.5% of cases, and oral anticoagulation (OAC) or other treatment modalities in 54.5%. Complete thrombus resolution was achieved in 95.0% of cases (100% with LMWH and 89.5% with OAC). Treatment duration varied greatly with a median treatment duration of 45 days (IQR: 14-135). Clinical events related to DAT consisted of neurologic events namely two transient ischemic attacks (2.4%) and four ischemic strokes (4.9%). CONCLUSIONS: DAT is an infrequent complication of percutaneous LAAO. It occurs mainly early after the procedure and is associated with a low rate of neurological complications. In the majority of cases, diagnosis is made during follow-up imaging with TEE. Anticoagulation treatment seems to be safe and highly effective. Further studies are needed to evaluate the optimal management of DAT. © 2017 Wiley Periodicals, Inc.


Asunto(s)
Apéndice Atrial/fisiopatología , Fibrilación Atrial/terapia , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Dispositivo Oclusor Septal/efectos adversos , Trombosis/epidemiología , Administración Oral , Anticoagulantes/administración & dosificación , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Ecocardiografía Transesofágica , Heparina de Bajo-Peso-Molecular/administración & dosificación , Humanos , Incidencia , Ataque Isquémico Transitorio/epidemiología , Factores de Riesgo , Accidente Cerebrovascular/epidemiología , Trombosis/diagnóstico por imagen , Trombosis/tratamiento farmacológico , Factores de Tiempo , Resultado del Tratamiento
6.
Europace ; 19(1): 4-15, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-27540038

RESUMEN

The increasing interest in left atrial appendage occlusion (LAAO) for ischaemic stroke prevention in atrial fibrillation (AF) fuels the need for more clinical data on the safety and effectiveness of this therapy. Besides an assessment of the effectiveness of the therapy in specific patients groups, comparisons with pharmacological stroke prophylaxis, surgical approaches, and other device-based therapies are warranted. This paper documents the consensus reached among clinical experts in relevant disciplines from Europe and North America, European cardiology professional societies, and representatives from the medical device industry regarding definitions for parameters and endpoints to be assessed in clinical studies. Adherence to these definitions is proposed in order to achieve a consistent approach across clinical studies on LAAO among the involved stakeholders and various clinical disciplines and thereby facilitate continued evaluation of therapeutic strategies available.


Asunto(s)
Apéndice Atrial/fisiopatología , Fibrilación Atrial/terapia , Isquemia Encefálica/prevención & control , Cateterismo Cardíaco , Recolección de Datos , Determinación de Punto Final , Proyectos de Investigación , Accidente Cerebrovascular/prevención & control , Fibrilación Atrial/complicaciones , Fibrilación Atrial/mortalidad , Fibrilación Atrial/fisiopatología , Isquemia Encefálica/etiología , Isquemia Encefálica/mortalidad , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/mortalidad , Consenso , Conducta Cooperativa , Humanos , Comunicación Interdisciplinaria , Cooperación Internacional , Selección de Paciente , Factores de Riesgo , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/mortalidad , Resultado del Tratamiento
7.
Catheter Cardiovasc Interv ; 87(7): 1324-30, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-26698175

RESUMEN

INTRODUCTION: The purpose of this study was to evaluate safety and efficacy of catheter-based occlusion of residual leaks after percutaneous closure of the left atrial appendage (LAA). METHODS: All cases of LAA closure at our center were reviewed to identify secondary interventions for residual leaks. Leaks with a width of more than 3 mm by transesophageal echocardiography (TEE) were considered relevant. In a case-specific approach, depending on the respective morphology of the defect, either an LAA occlusion device or an Amplatzer Vascular Plug was implanted under TEE and fluoroscopic guidance. RESULTS: Between June 2003 and December 2013, 12 patients underwent residual leak closure. All procedures were technically successful and without complications. In 10 cases (83%), complete sealing was confirmed at TEE follow-up. In 2 patients, minimal gaps (2-3 mm) persisted and anticoagulation was continued. None of the patients had strokes during the follow-up period. CONCLUSION: Percutaneous residual leak closure after attempted LAA occlusion can be done safely and with high procedural success rates. © 2015 Wiley Periodicals, Inc.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial/terapia , Cateterismo Cardíaco , Anciano , Anciano de 80 o más Años , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Ecocardiografía Doppler en Color , Ecocardiografía Tridimensional , Ecocardiografía Transesofágica , Diseño de Equipo , Femenino , Fluoroscopía , Alemania , Humanos , Masculino , Radiografía Intervencional/métodos , Retratamiento , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Factores de Tiempo , Resultado del Tratamiento
8.
Catheter Cardiovasc Interv ; 87(4): 787-94, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26354821

RESUMEN

OBJECTIVES: To evaluate the feasibility and safety of the fourth generation WATCHMAN device. BACKGROUND: The WATCHMAN left atrial appendage (LAA) closure device has been shown to be non-inferior to conventional oral anticoagulation with warfarin for stroke prevention in patients with non-valvular atrial fibrillation. A new (fourth) generation of the WATCHMAN device was designed to facilitate easier delivery and improve safety. METHODS: We conducted a prospective, non-randomized study of LAA closure with use of the 4(th) generation WATCHMAN device in 36 patients with non-valvular atrial fibrillation. Follow-up was performed at 45 days, 6 months and 12 months following implantation. RESULTS: The mean age of the population was 73 ± 6 years and 67% were male. The mean CHADS2 and CHA2 DS2-VASc Score were 2.5 and 4.5, respectively. The device was implanted successfully in 34/36 (94%). No serious hospital complications related to the device or procedure occurred. During 12 month follow-up, three ischemic strokes (8%), one hemorrhagic stroke (3%), one TIA (3%) and three deaths (9%) occurred. Device-associated thrombus formation was detected in one patient (3%) during six-month follow-up and was treated successfully with low molecular weight heparin. CONCLUSIONS: LAA closure with the 4(th) generation WATCHMAN device is feasible and safe. New technical features may contribute to a better performance of the occluder, particularly regarding the risk of pericardial effusions.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial/terapia , Cateterismo Cardíaco/instrumentación , Ataque Isquémico Transitorio/prevención & control , Diseño de Prótesis , Implantación de Prótesis/instrumentación , Accidente Cerebrovascular/prevención & control , Anciano , Anciano de 80 o más Años , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/fisiopatología , Fibrilación Atrial/complicaciones , Fibrilación Atrial/mortalidad , Fibrilación Atrial/fisiopatología , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/mortalidad , Ecocardiografía Transesofágica , Estudios de Factibilidad , Femenino , Estudios de Seguimiento , Humanos , Ataque Isquémico Transitorio/etiología , Ataque Isquémico Transitorio/mortalidad , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Implantación de Prótesis/efectos adversos , Implantación de Prótesis/mortalidad , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/mortalidad , Trombosis/etiología , Factores de Tiempo , Resultado del Tratamiento
9.
Catheter Cardiovasc Interv ; 87(1): E30-8, 2016 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-26104216

RESUMEN

OBJECTIVES: The purpose of this study was to identify predictors of BP response. BACKGROUND: Catheter-based renal denervation (RDN) causes significant blood pressure (BP) reductions in a large number of patients with resistant hypertension. METHODS: One hundred one consecutive patients with resistant hypertension who underwent RDN with the Symplicity™ catheter were included in this retrospective study. Primary endpoint was the change in office systolic BP after 6 months. Uni- and multivariate logistic regression analyses were performed to detect baseline predictors of a significant BP response 6 months after RDN (age, gender, office and ambulatory BP, renal function, body mass index [BMI], diabetes mellitus, antihypertensive medication, number of ablations). RESULTS: The procedure was technically uneventful in all patients. Mean BP at baseline was 166.6/90.2 ± 22.5/16.4 mmHg and decreased by -14.7 (P < 0.0001)/-5.3 (P < 0.001) ± 22.8/14.1 mm Hg at 6-month follow-up. Similarly, paired analysis of 24-hr-ambulatory BP measurement (n = 71) showed a significant reduction of mean systolic BP by 6.8 ± 14.4 mm Hg (P < 0.0002). Upon univariate analyses, a higher baseline office systolic BP (P < 0.0001) and lower BMI (P = 0.014) were identified as significant predictors of the magnitude of BP response after 6 months. Importantly, on multivariate analysis, baseline office systolic BP (standardized ß = -0.46; r = -0.47; P < 0.0001) and BMI (standardized ß = 0.21; r = 0.95; P = 0.019) remained significant. CONCLUSION: Blood pressure reductions after RDN were more pronounced in patients with higher baseline blood pressure and lower BMI. These findings may have implications regarding patient selection for renal denervation. © 2015 Wiley Periodicals, Inc.


Asunto(s)
Presión Sanguínea/fisiología , Hipertensión/terapia , Riñón/inervación , Obesidad/complicaciones , Simpatectomía/métodos , Monitoreo Ambulatorio de la Presión Arterial , Femenino , Estudios de Seguimiento , Humanos , Hipertensión/complicaciones , Hipertensión/fisiopatología , Masculino , Persona de Mediana Edad , Obesidad/fisiopatología , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento
10.
J Vasc Surg ; 62(5): 1168-75, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26238332

RESUMEN

BACKGROUND: There are few long term studies to show the safety and efficacy of iliac artery aneurysm exclusion, especially in regards to the straight iliac branched device. The objective of our study was to add our data with a mean follow-up of 32 months to the existing data available. METHODS: Patients undergoing iliac bifurcation procedure either as standalone or in combination with abdominal aortic aneurysm exclusion at two vascular centers had data prospectively gathered between 2004 and 2014. Collected data was analyzed for baseline characteristics, procedural events, and clinical follow-up; variables included endoleaks, reinterventions, and internal iliac artery (IIA) closure. RESULTS: A total of 45 iliac vessels in 41 patients (36 male) with a mean age of 70.4 years were treated with the iliac branched device. Procedural success was achieved in 85% (35/41) of patients and 87% (39/45) vessels with no intraoperative death. Of the six technical failures, three occurred due to failure to place the straight iliac branched device or stent properly. Two occurred because of endoleaks at the end of the procedure, and one occurred because the IIA side-branch occluded and could not be reopened. The mean patient follow-up was 32.0 ± 27.3 months (range, 0-109 months). During this time period, the IIA patency rate on an intention-to-treat basis was 81%, and the freedom from endoleak rate on an intention-to-treat basis was 76% per patient. The freedom from reintervention per patient was 75%. No patient reported symptoms of pelvic ischemia and permanent buttock claudication. CONCLUSIONS: In this study with mean follow-up of 32 months, treatment with iliac bifurcated devices is a safe and durable option in a carefully selected population of patients with iliac artery bifurcation aneurysms.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Procedimientos Endovasculares/instrumentación , Aneurisma Ilíaco/cirugía , Stents , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/diagnóstico , Aneurisma de la Aorta Abdominal/fisiopatología , Implantación de Prótesis Vascular/efectos adversos , Bases de Datos Factuales , Endofuga/etiología , Endofuga/terapia , Procedimientos Endovasculares/efectos adversos , Femenino , Alemania , Humanos , Aneurisma Ilíaco/diagnóstico , Aneurisma Ilíaco/fisiopatología , Análisis de Intención de Tratar , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Falla de Prótesis , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Ultrasonografía Doppler Dúplex , Grado de Desobstrucción Vascular
11.
Catheter Cardiovasc Interv ; 85(2): 297-303, 2015 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-25158644

RESUMEN

OBJECTIVES: Aim of this study was to demonstrate the feasibility, safety, and short-term outcome of left atrial appendage (LAA) closure with a new generation LAA closure device. BACKGROUND: The Amulet device (AGA, St Jude Medical, Minneapolis, MN) is a new generation of the amplatzer cardiac plug (ACP), specifically designed for LAA closure. This new version is designed to facilitate the implantation process and minimize procedural or device-related complications. METHODS: The device was implanted in 17 patients with nonvalvular atrial fibrillation (AF). Clinical data were obtained at baseline, during the procedure, at discharge, at 30 and 90 days. RESULTS: All devices were implanted successfully. Device sizes ranged from 20 mm to 31 mm. A 12 French (Fr) or 14 Fr delivery sheath was used depending on the selected device size. Full and partial recapture was performed in 1 case and 3 cases, respectively. There was 1 procedure-related pericardial effusion successfully managed with pericardiocentesis. There was no device embolization. The mean length of stay was 2.1 ± 0.3 days. At 90 days, there were no deaths, strokes, systemic thromboembolism, or bleeding complications. There was no device-related thrombus or pericardial effusion at 90-day TEE. In 2 of the 17 patients minimal peridevice flow (smaller than 2 mm) was present. CONCLUSIONS: The Amulet device, which has new novel features as compared with the first generation ACP, is a feasible option for LAA closure. From our initial experience, implantation of the Amulet is associated with high success rate and good short-term outcome.


Asunto(s)
Apéndice Atrial/fisiopatología , Fibrilación Atrial/terapia , Cateterismo Cardíaco/instrumentación , Anciano , Apéndice Atrial/diagnóstico por imagen , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Cateterismo Cardíaco/efectos adversos , Diseño de Equipo , Estudios de Factibilidad , Femenino , Humanos , Tiempo de Internación , Masculino , Persona de Mediana Edad , Radiografía Intervencional , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento
12.
Catheter Cardiovasc Interv ; 86(5): E224-8, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26010062

RESUMEN

OBJECTIVES: The purpose of this study is to determine feasibility, safety, and effectiveness of the "shape-the-sheath" method in left atrial appendage closure. BACKGROUND: LAA occlusion is often a difficult procedure, due to not just the learning curve but also the three-dimensional variable nature of the left atrial appendage. Multiple sheaths have been created for various takeoffs. The purpose of this article is to show the feasibility of the "shape-the-sheath" method in left atrial appendage closure. METHODS: Ten consecutive patients undergoing LAA occlusion without the "shape-the-sheath" method were compared to 10 consecutive patients undergoing LAA occlusion with the "shape-the-sheath" method using the Amplatzer Cardiac Plug (ACP) system and the Amplatzer TorqVue 45×45 sheath. RESULTS: The "shape-the-sheath" method resulted in significant decreases in fluoroscopy time (7.2±3.0 min vs. 13.7±6.7 min, P<0.05), number of partial recaptures (0% vs. 50%, P<0.05), with a trend toward decrease in the number of complete recaptures (0 vs. 40%, P=0.09) compared to conventional sheath use. CONCLUSIONS: Shaping-the-sheath is a simple, elegant way to help conform delivery systems to better access the LAA and ensure stable position. Further experience with this procedure optimization step is warranted.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial/terapia , Cateterismo Cardíaco/instrumentación , Catéteres Cardíacos , Anciano , Anciano de 80 o más Años , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Ecocardiografía Transesofágica , Diseño de Equipo , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Dosis de Radiación , Radiografía Intervencional , Resultado del Tratamiento
13.
J Interv Cardiol ; 28(2): 215-7, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25676602

RESUMEN

Structural heart disease requires a coordinated effort to join echocardiographic and fluoroscopic data. Various methods have been used, including echocardiography, CT, and MRI. We report on the use of EchoNavigator (Philips Inc., Amsterdam, Netherlands), a novel echocardiographic-fluoroscopic fusion system. This new system allows real-time integration and marking of important structures that track on fluoroscopy even with movement of the C-arm. In this article, we describe potential uses for this system in respect to transseptal puncture and left atrial appendage closure.


Asunto(s)
Apéndice Atrial/cirugía , Ecocardiografía/instrumentación , Fluoroscopía/instrumentación , Tabiques Cardíacos/cirugía , Cirugía Asistida por Computador/instrumentación , Humanos , Países Bajos , Punciones
14.
J Interv Cardiol ; 28(1): 76-81, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25689551

RESUMEN

OBJECTIVES: To describe the feasibility and safety of transcatheter aortic valve implantation (TAVI) with a visiting on-site cardiac surgery program for surgical back-up. BACKGROUND: Both European and American guidelines recommend institutional cardiac surgery back-up for TAVI. However, the conversion to cardiac surgery is very rare, many complications of TAVI can be managed by catheter techniques and a visiting team can also provide surgical stand-by. Therefore, the need for institutional cardiac surgery (by a surgeon who routinely performs conventional surgical valve replacement at the institution performing TAVI) has been questioned. METHODS: A retrospective review of consecutive TAVI cases with visiting on-site cardiac surgery was performed. Key demographic, echocardiographic, and procedural data were collected prospectively. RESULTS: A total of 97 patients (81.9 ± 6.3 years) with high-risk criteria (log Euroscore 21.6 ± 14.4, chronic renal failure 39.2%, severe systolic dysfunction 24.7%) underwent TAVI with visiting on-site cardiac surgery at our institution. Local anesthesia with or without conscious sedation was used in 94.8% of patients. Procedural technical success was 100%, with 2 episodes of tamponade (both treated with pericardiocentesis) and a 16.5% vascular complication rate (all treated conservatively or percutaneously). Thirty-day mortality was 3.1%, with 5.2% rate of stroke and 8.2% rate of major bleeding. There were no conversions to surgery. CONCLUSIONS: TAVI can be done safely in the setting of a hospital with visiting on-site cardiac surgery. This requires careful patient selection, experienced operators and surgeons in experienced centers with well-established criteria and processes of care. In this setting, it may be an option for hospitals without institutional cardiac surgery.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Seguridad del Paciente , Cirujanos , Reemplazo de la Válvula Aórtica Transcatéter , Anciano de 80 o más Años , Estudios de Cohortes , Estudios de Factibilidad , Femenino , Alemania , Humanos , Masculino , Estudios Retrospectivos
15.
Circ J ; 79(2): 237-44, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25744737

RESUMEN

Heart failure is a growing epidemic, with more patients living longer and suffering from this disease. There is a growing segment of patients who have persistent symptoms despite pharmacologic therapy. In an era when transplants are rare, the need for devices and interventions that can assist ventricular function is paramount. This review goes through the devices used in heart failure, including left ventricular reconstruction, aortic counterpulsation, short-term mechanical circulatory support, long-term mechanical circulatory support, and right heart interventions.


Asunto(s)
Insuficiencia Cardíaca/terapia , Corazón Auxiliar , Insuficiencia Cardíaca/epidemiología , Humanos
16.
Catheter Cardiovasc Interv ; 84(1): 147-54, 2014 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-24038891

RESUMEN

INTRODUCTION: Paravalvular leak (PVL) after percutaneous transcatheter aortic valve replacement (TAVR) is associated with significant morbidity and mortality. Percutaneous PVL closure has been reported for balloon-expandable valves but not self-expandable valves. METHODS: We conducted a review of cases at our center where patients who received TAVR with self-expandable valves and went on to develop severe PVL underwent percutaneous closure. Baseline demographic, TAVR procedural, PVL procedural, and follow-up data were collected. RESULTS: A total of five patients with severe PVL after TAVR with a self-expanding valve underwent percutaneous PVL closure. Four of five patients had a trial of balloon postdilatation after valve deployment and had significant persistent PVL. In all five patients, PVL went from moderate-severe to mild-moderate PVL. There were no adverse events. CONCLUSION: Percutaneous PVL closure for severe PVL self-expanding valve for TAVR is a safe and efficacious procedure. Procedural technique involves transesophageal guidance, a high approach through the valve struts, deployment of an appropriate size device, and careful monitoring. This method may be part of the algorithm for severe PVL after TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Cateterismo Cardíaco/métodos , Prótesis Valvulares Cardíacas , Complicaciones Posoperatorias/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Humanos , Masculino , Diseño de Prótesis , Reoperación , Estudios Retrospectivos
17.
Catheter Cardiovasc Interv ; 83(5): 805-10, 2014 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-24259397

RESUMEN

OBJECTIVES: To determine the procedural safety, safety, and efficacy of left atrial appendage (LAA) occlusion in octogenarians. BACKGROUND: Elderly patients with atrial fibrillation (AF) often do not receive appropriate anticoagulation. LAA occlusion is an option for patients with AF and contraindications to anticoagulation. Not much is known about the procedural safety and clinical efficacy of LAA occlusion in the very elderly. METHODS: A retrospective review of LAA cases at our institution between 2002 and 2013 in patients 80 years of age or older was performed. Demographic, echocardiographic, procedural, and clinical follow-up data were collected. RESULTS: Seventy-five cases were attempted in patients 80 years of age or older (average age 83.4 ± 2.8 years, 53.3% males). Hypertension, coronary artery disease, and heart failure were present in 96, 41.3, and 36%, respectively. Mean CHADS2 and CHA2DS-VASc scores were 3.3 and 5.2. Devices used included the WATCHMAN, ACP, PLAATO, Lariat, and Coherex devices, which were attempted in 34.7, 36, 17.3, 5.3, and 5.3%, respectively. Overall procedural success, safety endpoint, and 1-year device efficacy was 90.1, 3.9, and 97.4%, respectively. CONCLUSION: LAA closure is a safe and efficacious method of stroke prevention in the very elderly with AF.


Asunto(s)
Apéndice Atrial/fisiopatología , Fibrilación Atrial/terapia , Cateterismo Cardíaco , Accidente Cerebrovascular/prevención & control , Factores de Edad , Anciano de 80 o más Años , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Diseño de Equipo , Femenino , Alemania , Humanos , Masculino , Estudios Retrospectivos , Factores de Riesgo , Accidente Cerebrovascular/etiología , Factores de Tiempo , Resultado del Tratamiento
18.
J Interv Cardiol ; 27(4): 414-22, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25059287

RESUMEN

OBJECTIVES: To report procedural outcome of sequential occlusion of the left atrial appendage (LAA) and an interatrial septal communication and discuss possible indications. BACKGROUND: There are some patients who may have indications for both closure of patent foramen ovale (PFO) or atrial septal defect (ASD), as well as closure of the LAA. The optimal procedural strategy is not known. METHODS: A retrospective review of LAA and PFO/ASD cases at our center was performed. Demographic, echocardiographic, and procedural data were recorded. RESULTS: Closure of LAA and then PFO/ASD (Group I: 11 patients), closure of both in the same setting (Group II: 3 patients), and closure of the PFO/ASD and then the LAA (Group III: 3 patients) was performed in a total of 17 patients. Average age was 63.5 ± 9.8 years. Most patients were hypertensive with prior cerebrovascular event in 52.9% of patients. Procedural success was 100%. Procedural adverse events were 2 episodes of tamponade (in Group I after first LAA procedure) treated with pericardiocentesis and 1 access-site hematoma (Group II) treated conservatively. CONCLUSIONS: Sequential (staged or during the same procedure) closure of the LAA and interatrial communications can be performed safely in a carefully selected patient population. This is also the first known report of LAA occlusion in patients with prior septal closure devices.


Asunto(s)
Apéndice Atrial/cirugía , Foramen Oval Permeable/cirugía , Defectos del Tabique Interatrial/cirugía , Dispositivo Oclusor Septal , Cateterismo Cardíaco , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
19.
J Interv Cardiol ; 27(5): 516-24, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25203054

RESUMEN

BACKGROUND: MitraClip® therapy is an alternative to conventional surgery. The aim was to characterize the mitral annular geometry pre- and postrepair with the MitraClip® taking into account the regurgitation mechanism. METHODS: We retrospectively collected pre- and postprocedural transesophageal echocardiography data in 46 patients. Patients were categorized as having isolated degenerative (DMR, n = 18), isolated functional (FMR, n = 9) or a combination of both functional and degenerative mitral regurgitation (MMR, n = 19). RESULTS: A significant reduction in septolateral (SL) diameters in all patients occurred. Noteworthy, in those with DMR, there was no significant change in intercommissural (IC) diameters whereas in those with FMR and MMR, it increased significantly in systole (FMR: +2.8 ± 3.4 mm, P = 0.03, MMR: +2.1 ± 2.6 mm, P = 0.002). In DMR, a significant reduction in mitral annular areas post-procedure was observed (-1.8 ± 2.3 cm(2), P = 0.001 in diast., -0.8 ± 1.0 cm(2), P = 0.004 in syst.). In patients with FMR and MMR, though the SL diameter decreased, this occurred at the expense of an increase in IC diameter causing a change in annular shape but leaving the annular area unchanged. Nevertheless, a comparable reduction in regurgitant severity (DMR: P = <0.001; FMR: P = 0.003; MMR: P = <0.001) and improvement in functional class occurred regardless of regurgitant mechanism. CONCLUSIONS: Though changes in mitral annular geometry after MitraClip® repair differ depending on regurgitant mechanism, this does not appear to have an impact on residual regurgitation or clinical status in the short-term.


Asunto(s)
Anuloplastia de la Válvula Cardíaca/instrumentación , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Anciano , Anciano de 80 o más Años , Ecocardiografía Transesofágica , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
20.
Eur J Heart Fail ; 26(4): 1065-1077, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38606485

RESUMEN

AIMS: Patients with heart failure and mildly reduced or preserved ejection fraction have limited therapeutic options. The ALT-FLOW Early Feasibility Study evaluated safety, haemodynamics and outcomes for the APTURE transcatheter shunt system, a novel left atrium to coronary sinus shunt in these patients. METHODS AND RESULTS: Safety and shunt implantation success was evaluated for all 116 enrolled patients. An analysis population of implanted patients with a left ventricular ejection fraction (LVEF) >40% (n = 95) was chosen to assess efficacy via paired comparison between baseline and follow-up haemodynamic (3 and 6 months), and echocardiographic, clinical and functional outcomes (6 months and 1 year). Health status and quality of life outcomes were assessed using the Kansas City Cardiomyopathy Questionnaire overall summary score (KCCQ-OSS). The primary safety endpoint, major adverse cardiac, cerebral, and renal events, and reintervention through 30 days, occurred in 3/116 patients (2.6%). All implanted shunts were patent at 1 year. In patients with LVEF >40%, the mean (95% confidence interval) reduction in exercise pulmonary capillary wedge pressure (PCWP) at 20 W was -5.7 (-8.6, -2.9) mmHg at 6 months (p < 0.001). At baseline, 8% had New York Heart Association class I-II status and improved to 68% at 1 year (p < 0.001). KCCQ-OSS at baseline was 39 (35, 43) and improved at 6 months and 1 year by 25 (20-30) and 27 (22-32) points, respectively (both p < 0.0001). No adverse changes in haemodynamic and echocardiographic indices of right heart function were observed at 1 year. Overall, the reduction in PCWP at 20 W and improvement in KCCQ-OSS in multiple subgroups were consistent with those observed for the entire population. CONCLUSIONS: In patients with heart failure and LVEF >40%, the APTURE shunt demonstrated an acceptable safety profile with significant sustained improvements in haemodynamic and patient-centred outcomes, underscoring the need for further evaluation of the APTURE shunt in a randomized trial.


Asunto(s)
Seno Coronario , Estudios de Factibilidad , Atrios Cardíacos , Insuficiencia Cardíaca , Volumen Sistólico , Humanos , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/cirugía , Insuficiencia Cardíaca/terapia , Femenino , Masculino , Volumen Sistólico/fisiología , Anciano , Atrios Cardíacos/fisiopatología , Atrios Cardíacos/diagnóstico por imagen , Seno Coronario/fisiopatología , Resultado del Tratamiento , Persona de Mediana Edad , Ecocardiografía/métodos , Calidad de Vida , Cateterismo Cardíaco/métodos , Estudios Prospectivos , Función Ventricular Izquierda/fisiología , Estudios de Seguimiento , Hemodinámica/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA