Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Clin Microbiol ; 54(2): 392-400, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26659206

RESUMEN

Digital PCR (dPCR) is being increasingly used for the quantification of sequence variations, including single nucleotide polymorphisms (SNPs), due to its high accuracy and precision in comparison with techniques such as quantitative PCR (qPCR) and melt curve analysis. To develop and evaluate dPCR for SNP detection using DNA, RNA, and clinical samples, an influenza virus model of resistance to oseltamivir (Tamiflu) was used. First, this study was able to recognize and reduce off-target amplification in dPCR quantification, thereby enabling technical sensitivities down to 0.1% SNP abundance at a range of template concentrations, a 50-fold improvement on the qPCR assay used routinely in the clinic. Second, a method was developed for determining the false-positive rate (background) signal. Finally, comparison of dPCR with qPCR results on clinical samples demonstrated the potential impact dPCR could have on clinical research and patient management by earlier (trace) detection of rare drug-resistant sequence variants. Ultimately this could reduce the quantity of ineffective drugs taken and facilitate early switching to alternative medication when available. In the short term such methods could advance our understanding of microbial dynamics and therapeutic responses in a range of infectious diseases such as HIV, viral hepatitis, and tuberculosis. Furthermore, the findings presented here are directly relevant to other diagnostic areas, such as the detection of rare SNPs in malignancy, monitoring of graft rejection, and fetal screening.


Asunto(s)
Antivirales/farmacología , Farmacorresistencia Viral , Virus de la Influenza A/efectos de los fármacos , Virus de la Influenza A/genética , Gripe Humana/diagnóstico , Gripe Humana/virología , Mutación , Antivirales/uso terapéutico , Genes Virales , Humanos , Subtipo H1N1 del Virus de la Influenza A/efectos de los fármacos , Subtipo H1N1 del Virus de la Influenza A/genética , Gripe Humana/tratamiento farmacológico , Tipificación Molecular , Oseltamivir/farmacología , Polimorfismo de Nucleótido Simple , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , Sensibilidad y Especificidad
2.
Nat Methods ; 10(11): 1063-7, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24173381

RESUMEN

Two surveys of over 1,700 publications whose authors use quantitative real-time PCR (qPCR) reveal a lack of transparent and comprehensive reporting of essential technical information. Reporting standards are significantly improved in publications that cite the Minimum Information for Publication of Quantitative Real-Time PCR Experiments (MIQE) guidelines, although such publications are still vastly outnumbered by those that do not.


Asunto(s)
Servicios de Información , Reacción en Cadena de la Polimerasa/métodos , Recolección de Datos
3.
Clin Infect Dis ; 60(6): 919-23, 2015 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-25572898

RESUMEN

Metagenomic next-generation sequencing (NGS) was used to diagnose an unusual and fatal case of progressive encephalitis in an immunocompromised adult presenting at disease onset as bilateral hearing loss. The sequencing and confirmatory studies revealed neuroinvasive infection of the brain by an astrovirus belonging to a recently discovered VA/HMO clade.


Asunto(s)
Infecciones por Astroviridae/diagnóstico , Encefalitis Viral/diagnóstico , Mamastrovirus/genética , Mamastrovirus/aislamiento & purificación , Adulto , Encéfalo/patología , Proteínas de la Cápside/genética , Encefalitis Viral/complicaciones , Resultado Fatal , Pérdida Auditiva Bilateral/etiología , Secuenciación de Nucleótidos de Alto Rendimiento/métodos , Humanos , Leucemia Linfoide/complicaciones , Filogenia
4.
Clin Infect Dis ; 61(1): 120-8, 2015 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-25778749

RESUMEN

BACKGROUND: Emerging data relating to human immunodeficiency virus type 1 (HIV-1) cure suggest that vaccination to stimulate the host immune response, particularly cytotoxic cells, may be critical to clearing of reactivated HIV-1-infected cells. However, evidence for this approach in humans is lacking, and parameters required for a vaccine are unknown because opportunities to study HIV-1 reactivation are rare. METHODS: We present observations from a HIV-1 elite controller, not treated with combination antiretroviral therapy, who experienced viral reactivation following treatment for myeloma with melphalan and autologous stem cell transplantation. Mathematical modeling was performed using a standard viral dynamic model. Enzyme-linked immunospot, intracellular cytokine staining, and tetramer staining were performed on peripheral blood mononuclear cells; in vitro CD8 T-cell-mediated control of virion production by autologous CD4 T cells was quantified; and neutralizing antibody titers were measured. RESULTS: Viral rebound was measured at 28,000 copies/mL on day 13 post-transplant before rapid decay to <50 copies/mL in 2 distinct phases with t1/2 of 0.71 days and 4.1 days. These kinetics were consistent with an expansion of cytotoxic effector cells and killing of productively infected CD4 T cells. Following transplantation, innate immune cells, including natural killer cells, recovered with virus rebound. However, most striking was the expansion of highly functional HIV-1-specific cytotoxic CD8 T cells, at numbers consistent with those applied in modeling, as virus control was regained. CONCLUSIONS: These observations provide evidence that the human immune response is capable of controlling coordinated global HIV-1 reactivation, remarkably with potency equivalent to combination antiretroviral therapy. These data will inform design of vaccines for use in HIV-1 curative interventions.


Asunto(s)
Infecciones por VIH/inmunología , Infecciones por VIH/virología , VIH-1/inmunología , VIH-1/fisiología , Activación Viral/inmunología , Anticuerpos Neutralizantes/sangre , Linfocitos T CD4-Positivos/virología , Linfocitos T CD8-positivos/inmunología , Citocinas/análisis , Ensayo de Immunospot Ligado a Enzimas , Anticuerpos Anti-VIH/sangre , Infecciones por VIH/complicaciones , Humanos , Leucocitos Mononucleares/inmunología , Leucocitos Mononucleares/virología , Melfalán/efectos adversos , Melfalán/uso terapéutico , Persona de Mediana Edad , Modelos Teóricos , Mieloma Múltiple/tratamiento farmacológico , Agonistas Mieloablativos/efectos adversos , Agonistas Mieloablativos/uso terapéutico , Trasplante de Células Madre/efectos adversos , Subgrupos de Linfocitos T/inmunología , Trasplante Autólogo
6.
Anal Chem ; 86(9): 4387-94, 2014 May 06.
Artículo en Inglés | MEDLINE | ID: mdl-24684191

RESUMEN

Performing nucleic acid amplification techniques (NAATs) in digital format using limiting dilution provides potential advantages that have recently been demonstrated with digital polymerase chain reaction (dPCR). Key benefits that have been claimed are the ability to quantify nucleic acids without the need of an external calibrator and a greater resistance to inhibitors than real-time quantitative PCR (qPCR). In this study, we evaluated the performance of four NAATs, qPCR, dPCR, real-time quantitative loop mediated isothermal amplification (qLAMP), and digital LAMP (dLAMP), for the detection and quantification of human cytomegalovirus (hCMV). We used various DNA templates and inhibitors to compare the performance of these methods using a conventional real-time thermocycler platform (Bio-Rad CFX96) and a chip based digital platform (Fluidigm Biomark 12.765 Digital Array). dPCR performed well and demonstrated greater resistance to inhibitors than the other methods although this resistance did not apply equally to all inhibitors tested. dLAMP was found to be less sensitive than dPCR, but its quantitative performance was better than qLAMP, the latter being unable to quantify below 1000 copies. dLAMP was also more resistant to inhibitors than qLAMP. Unlike qPCR, both digital methods were able to quantify viral genomes without requiring a calibrator; however, neither can currently compete with the large reaction volumes, and thus the greater absolute sensitivity, of qPCR. With the introduction of digital instrumentation that will enable larger reaction volumes, digital amplification methods such as those evaluated in this study could potentially offer a robust alternative to qPCR for nucleic acid quantification.


Asunto(s)
Citomegalovirus/aislamiento & purificación , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Citomegalovirus/genética , ADN Viral/genética , Límite de Detección
7.
Transfusion ; 54(3 Pt 2): 870-8, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23701338

RESUMEN

BACKGROUND: Culture-based systems are currently the preferred means for bacterial screening of platelet (PLT) concentrates. Alternative bacterial detection techniques based on nucleic acid amplification have also been developed but these have yet to be fully evaluated. In this study we evaluate a novel 16S rDNA polymerase chain reaction (PCR) assay and compare its performance with automated culture. STUDY DESIGN AND METHODS: A total of 2050 time-expired, 176 fresh, and 400 initial-reactive PLT packs were tested by real-time PCR using broadly reactive 16S primers and a "universal" probe (TaqMan, Invitrogen). PLTs were also tested using a microbial detection system (BacT/ALERT, bioMérieux) under aerobic and anaerobic conditions. RESULTS: Seven of 2050 (0.34%) time-expired PLTs were found repeat reactive by PCR on the initial nucleic acid extract but none of these was confirmed positive on testing frozen second aliquots. BacT/ALERT testing also failed to confirm any time-expired PLTs positive on repeat testing, although 0.24% were reactive on the first test. Three of the 400 "initial-reactive" PLT packs were found by both PCR and BacT/ALERT to be contaminated (Escherichia coli, Listeria monocytogenes, and Streptococcus vestibularis identified) and 14 additional packs were confirmed positive by BacT/ALERT only. In 13 of these cases the contaminating organisms were identified as anaerobic skin or oral commensals and the remaining pack was contaminated with Streptococcus pneumoniae. CONCLUSION: These results demonstrate that the 16S PCR assay is less sensitive than BacT/ALERT and inappropriate for early testing of concentrates. However, rapid PCR assays such as this may be suitable for a strategy of late or prerelease testing.


Asunto(s)
Azidas/química , Plaquetas/citología , ADN Ribosómico/química , Reacción en Cadena de la Polimerasa/métodos , Plaquetas/metabolismo , Humanos
8.
Clin Chem ; 59(6): 892-902, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23570709

RESUMEN

There is growing interest in digital PCR (dPCR) because technological progress makes it a practical and increasingly affordable technology. dPCR allows the precise quantification of nucleic acids, facilitating the measurement of small percentage differences and quantification of rare variants. dPCR may also be more reproducible and less susceptible to inhibition than quantitative real-time PCR (qPCR). Consequently, dPCR has the potential to have a substantial impact on research as well as diagnostic applications. However, as with qPCR, the ability to perform robust meaningful experiments requires careful design and adequate controls. To assist independent evaluation of experimental data, comprehensive disclosure of all relevant experimental details is required. To facilitate this process we present the Minimum Information for Publication of Quantitative Digital PCR Experiments guidelines. This report addresses known requirements for dPCR that have already been identified during this early stage of its development and commercial implementation. Adoption of these guidelines by the scientific community will help to standardize experimental protocols, maximize efficient utilization of resources, and enhance the impact of this promising new technology.


Asunto(s)
Computadores/normas , Guías como Asunto , Reacción en Cadena en Tiempo Real de la Polimerasa/normas , Computadores/estadística & datos numéricos
9.
Transfusion ; 52(7): 1423-32, 2012 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-22188457

RESUMEN

BACKGROUND: Bacterial contamination of platelet (PLT) concentrates remains a problem for blood transfusion services. Culture-based bacterial screening techniques are available but offer inadequate speed and sensitivity. Alternative techniques based on polymerase chain reaction (PCR) amplification have been described but their performance is often compromised by traces of bacterial DNA in reagents. STUDY DESIGN AND METHODS: Universal 16S rDNA primers were used to develop a real-time PCR assay (TaqMan, Applied Biosystems) and various reagent decontamination strategies were explored. Detection sensitivity was assessed by spiking PLT concentrates with known concentrations of 13 different organisms. RESULTS: Restriction enzyme digestion, master mix ultrafiltration, and use of alternative Taq polymerases all reduced the level of reagent DNA contamination to some extent but all proved unreliable. In contrast, ethidium monoazide (EMA) treatment of the PCR master mix followed by photoactivation was reliable and effective, permitting a full 40 amplification cycles, and totally eliminated contamination without compromising assay sensitivity. All 13 organisms were efficiently detected and the limit of detection for Escherichia coli-spiked PLTs was approximately 1 colony-forming unit/mL. Coamplification of human mitochondrial DNA served to confirm efficient nucleic acid extraction and the absence of PCR inhibition in each sample. One of five automated extraction platforms evaluated was found to be contamination free and capable of high-throughput processing. CONCLUSION: Cross-linking of EMA to DNA via photoactivation solved the previously intractable problem of reagent contamination and permitted the development of a high-sensitivity universal bacterial detection system. Trials are ongoing to assess the suitability of the system for high-throughput screening of PLT concentrates.


Asunto(s)
Azidas/química , Bacterias/genética , Plaquetas/microbiología , ADN Bacteriano/genética , ADN Ribosómico/genética , Reacción en Cadena de la Polimerasa/métodos , ARN Ribosómico 16S/genética , ADN Bacteriano/sangre , ADN Ribosómico/sangre , Humanos , Transfusión de Plaquetas , ARN Ribosómico 16S/sangre
10.
J Clin Virol ; 146: 105049, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34871906

RESUMEN

BACKGROUND: The highly transmissible Delta variant of SARS-CoV-2 (B.1.617.2), first identified in India, is currently replacing pre-existing variants in many parts of the world. To help guide public health policies it is important to monitor efficiently its spread. Genome sequencing is the gold standard for identification of Delta, but is time-consuming, expensive, and unavailable in many regions. OBJECTIVE: To develop and evaluate a rapid, simple and inexpensive alternative to sequencing for Delta identification. METHODS: A double-mismatch allele-specific RT-PCR (DMAS-RT-PCR) was developed. The technique exploits allele-specific primers, targeting two spike gene mutations, L452R and T478K, within the same amplicon. The discriminatory power of each primer was enhanced by an additional mismatch located at the fourth nucleotide from the 3' end. Specificity was assessed by testing well characterised cell culture-derived viral isolates and clinical samples, most of which had previously been fully sequenced. RESULTS: In all cases the results of viral genotyping by DMAS-RT-PCR were entirely concordant with the results of sequencing, and the assay was shown to discriminate reliably between the Delta variant and other variants (Alpha and Beta), and 'wild-type' SARS-CoV-2. Influenza A and RSV were non-reactive in the assay. The sensitivity of DMAS-RT-PCR matched that of the diagnostic SARS-CoV-2 RT-qPCR screening assay. Several samples that could not be sequenced due to insufficient virus were successfully genotyped by DMAS-RT-PCR. CONCLUSION: The method we describe would be simple to establish in any laboratory that can conduct PCR assays and should greatly facilitate monitoring of the spread of the Delta variant globally.


Asunto(s)
COVID-19 , SARS-CoV-2 , Alelos , Humanos , Reacción en Cadena en Tiempo Real de la Polimerasa , Transcripción Reversa , Sensibilidad y Especificidad
11.
Retrovirology ; 8: 13, 2011 Feb 25.
Artículo en Inglés | MEDLINE | ID: mdl-21352548

RESUMEN

XMRV is a gammaretrovirus associated in some studies with human prostate cancer and chronic fatigue syndrome. Central to the hypothesis of XMRV as a human pathogen is the description of integration sites in DNA from prostate tumour tissues. Here we demonstrate that 2 of 14 patient-derived sites are identical to sites cloned in the same laboratory from experimentally infected DU145 cells. Identical integration sites have never previously been described in any retrovirus infection. We propose that the patient-derived sites are the result of PCR contamination. This observation further undermines the notion that XMRV is a genuine human pathogen.


Asunto(s)
Contaminación de ADN , Reacción en Cadena de la Polimerasa/métodos , Próstata/virología , Neoplasias de la Próstata/virología , Integración Viral/genética , Virus Relacionado con el Virus Xenotrópico de la Leucemia Murina/genética , Secuencia de Bases , Línea Celular Tumoral , ADN Viral/análisis , ADN Viral/genética , Humanos , Masculino , Datos de Secuencia Molecular , Próstata/patología , Neoplasias de la Próstata/genética , Virus Relacionado con el Virus Xenotrópico de la Leucemia Murina/patogenicidad
12.
J Clin Microbiol ; 49(10): 3491-7, 2011 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21813718

RESUMEN

Accurate HIV-2 plasma viral load quantification is crucial for adequate HIV-2 patient management and for the proper conduct of clinical trials and international cohort collaborations. This study compared the homogeneity of HIV-2 RNA quantification when using HIV-2 assays from ACHI(E)V(2E) study sites and either in-house PCR calibration standards or common viral load standards supplied to all collaborators. Each of the 12 participating laboratories quantified blinded HIV-2 samples, using its own HIV-2 viral load assay and standard as well as centrally validated and distributed common HIV-2 group A and B standards (http://www.hiv.lanl.gov/content/sequence/HelpDocs/subtypes-more.html). Aliquots of HIV-2 group A and B strains, each at 2 theoretical concentrations (2.7 and 3.7 log(10) copies/ml), were tested. Intralaboratory, interlaboratory, and overall variances of quantification results obtained with both standards were compared using F tests. For HIV-2 group A quantifications, overall and interlaboratory and/or intralaboratory variances were significantly lower when using the common standard than when using in-house standards at the concentration levels of 2.7 log(10) copies/ml and 3.7 log(10) copies/ml, respectively. For HIV-2 group B, a high heterogeneity was observed and the variances did not differ according to the type of standard used. In this international collaboration, the use of a common standard improved the homogeneity of HIV-2 group A RNA quantification only. The diversity of HIV-2 group B, particularly in PCR primer-binding regions, may explain the heterogeneity in quantification of this strain. Development of a validated HIV-2 viral load assay that accurately quantifies distinct circulating strains is needed.


Asunto(s)
Infecciones por VIH/virología , VIH-2/aislamiento & purificación , Carga Viral/métodos , Humanos , Cooperación Internacional , Variaciones Dependientes del Observador , Plasma/virología , Control de Calidad , Estándares de Referencia , Reproducibilidad de los Resultados , Carga Viral/normas
13.
J Virol Methods ; 294: 114174, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-33984396

RESUMEN

There is growing evidence that measurement of SARS-CoV-2 viral copy number can inform clinical and public health management of SARS-CoV-2 carriers and COVID-19 patients. Here we show that quantification of SARS-CoV-2 is feasible in a clinical setting, using a duplex RT-qPCR assay which targets both the E gene (Charité assay) and a human RNA transcript, RNase P (CDC assay) as an internal sample sufficiency control. Samples in which RNase P is not amplified indicate that sample degradation has occurred, PCR inhibitors are present, RNA extraction has failed or swabbing technique was insufficient. This important internal control reveals that 2.4 % of nasopharyngeal swabs (15/618 samples) are inadequate for SARS-CoV-2 testing which, if not identified, could result in false negative results. We show that our assay is linear across at least 7 logs and is highly reproducible, enabling the conversion of Cq values to viral copy numbers using a standard curve. Furthermore, the SARS-CoV-2 copy number was independent of the RNase P copy number indicating that the per-swab viral copy number is not dependent on sampling- further allowing comparisons between samples. The ability to quantify SARS-CoV-2 viral copy number will provide an important opportunity for viral burden-guided public health and clinical decision making.


Asunto(s)
Prueba de Ácido Nucleico para COVID-19/métodos , Prueba de Ácido Nucleico para COVID-19/normas , ARN Viral/genética , SARS-CoV-2/genética , Manejo de Especímenes/normas , COVID-19/diagnóstico , COVID-19/virología , Dosificación de Gen , Genes Esenciales , Humanos , Límite de Detección , ARN Viral/aislamiento & purificación , Estándares de Referencia , Ribonucleasa P/genética , Manejo de Especímenes/métodos , Carga Viral
14.
Sci Rep ; 11(1): 14283, 2021 07 12.
Artículo en Inglés | MEDLINE | ID: mdl-34253796

RESUMEN

There is increasing evidence that endogenous retroviruses (ERVs) play a significant role in central nervous system diseases, including amyotrophic lateral sclerosis (ALS). Studies of ALS have consistently identified retroviral enzyme reverse transcriptase activity in patients. Evidence indicates that ERVs are the cause of reverse transcriptase activity in ALS, but it is currently unclear whether this is due to a specific ERV locus or a family of ERVs. We employed a combination of bioinformatic methods to identify whether specific ERVs or ERV families are associated with ALS. Using the largest post-mortem RNA-sequence datasets available we selectively identified ERVs that closely resembled full-length proviruses. In the discovery dataset there was one ERV locus (HML6_3p21.31c) that showed significant increased expression in post-mortem motor cortex tissue after multiple-testing correction. Using six replication post-mortem datasets we found HML6_3p21.31c was consistently upregulated in ALS in motor cortex and cerebellum tissue. In addition, HML6_3p21.31c showed significant co-expression with cytokine binding and genes involved in EBV, HTLV-1 and HIV type-1 infections. There were no significant differences in ERV family expression between ALS and controls. Our results support the hypothesis that specific ERV loci are involved in ALS pathology.


Asunto(s)
Esclerosis Amiotrófica Lateral/virología , Retrovirus Endógenos/genética , Corteza Motora/metabolismo , Anciano , Esclerosis Amiotrófica Lateral/metabolismo , Esclerosis Amiotrófica Lateral/mortalidad , Animales , Cerebelo/metabolismo , Corteza Cerebral/metabolismo , Biología Computacional , Citocinas/metabolismo , Bases de Datos Factuales , Femenino , Perfilación de la Expresión Génica , Regulación de la Expresión Génica , VIH/metabolismo , Humanos , Masculino , Persona de Mediana Edad , Provirus/genética , RNA-Seq
15.
Retrovirology ; 7(1): 111, 2010 Dec 20.
Artículo en Inglés | MEDLINE | ID: mdl-21171979

RESUMEN

BACKGROUND: Xenotropic murine leukaemia viruses (MLV-X) are endogenous gammaretroviruses that infect cells from many species, including humans. Xenotropic murine leukaemia virus-related virus (XMRV) is a retrovirus that has been the subject of intense debate since its detection in samples from humans with prostate cancer (PC) and chronic fatigue syndrome (CFS). Controversy has arisen from the failure of some studies to detect XMRV in PC or CFS patients and from inconsistent detection of XMRV in healthy controls. RESULTS: Here we demonstrate that Taqman PCR primers previously described as XMRV-specific can amplify common murine endogenous viral sequences from mouse suggesting that mouse DNA can contaminate patient samples and confound specific XMRV detection. To consider the provenance of XMRV we sequenced XMRV from the cell line 22Rv1, which is infected with an MLV-X that is indistinguishable from patient derived XMRV. Bayesian phylogenies clearly show that XMRV sequences reportedly derived from unlinked patients form a monophyletic clade with interspersed 22Rv1 clones (posterior probability >0.99). The cell line-derived sequences are ancestral to the patient-derived sequences (posterior probability >0.99). Furthermore, pol sequences apparently amplified from PC patient material (VP29 and VP184) are recombinants of XMRV and Moloney MLV (MoMLV) a virus with an envelope that lacks tropism for human cells. Considering the diversity of XMRV we show that the mean pairwise genetic distance among env and pol 22Rv1-derived sequences exceeds that of patient-associated sequences (Wilcoxon rank sum test: p = 0.005 and p < 0.001 for pol and env, respectively). Thus XMRV sequences acquire diversity in a cell line but not in patient samples. These observations are difficult to reconcile with the hypothesis that published XMRV sequences are related by a process of infectious transmission. CONCLUSIONS: We provide several independent lines of evidence that XMRV detected by sensitive PCR methods in patient samples is the likely result of PCR contamination with mouse DNA and that the described clones of XMRV arose from the tumour cell line 22Rv1, which was probably infected with XMRV during xenografting in mice. We propose that XMRV might not be a genuine human pathogen.


Asunto(s)
Contaminación de ADN , Síndrome de Fatiga Crónica/virología , Neoplasias de la Próstata/virología , Virología/métodos , Virus Relacionado con el Virus Xenotrópico de la Leucemia Murina/genética , Virus Relacionado con el Virus Xenotrópico de la Leucemia Murina/aislamiento & purificación , Animales , ADN Viral/química , ADN Viral/genética , Humanos , Masculino , Ratones , Datos de Secuencia Molecular , Reacción en Cadena de la Polimerasa/métodos , Análisis de Secuencia de ADN
16.
Clin Chem ; 55(4): 611-22, 2009 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-19246619

RESUMEN

BACKGROUND: Currently, a lack of consensus exists on how best to perform and interpret quantitative real-time PCR (qPCR) experiments. The problem is exacerbated by a lack of sufficient experimental detail in many publications, which impedes a reader's ability to evaluate critically the quality of the results presented or to repeat the experiments. CONTENT: The Minimum Information for Publication of Quantitative Real-Time PCR Experiments (MIQE) guidelines target the reliability of results to help ensure the integrity of the scientific literature, promote consistency between laboratories, and increase experimental transparency. MIQE is a set of guidelines that describe the minimum information necessary for evaluating qPCR experiments. Included is a checklist to accompany the initial submission of a manuscript to the publisher. By providing all relevant experimental conditions and assay characteristics, reviewers can assess the validity of the protocols used. Full disclosure of all reagents, sequences, and analysis methods is necessary to enable other investigators to reproduce results. MIQE details should be published either in abbreviated form or as an online supplement. SUMMARY: Following these guidelines will encourage better experimental practice, allowing more reliable and unequivocal interpretation of qPCR results.


Asunto(s)
Reacción en Cadena de la Polimerasa/métodos , Reacción en Cadena de la Polimerasa/normas , Edición/normas , Humanos , Técnicas de Diagnóstico Molecular , Ácidos Nucleicos/química , Ácidos Nucleicos/genética , Transcripción Reversa/genética , Terminología como Asunto , Factores de Tiempo
17.
J Virol Methods ; 268: 17-23, 2019 06.
Artículo en Inglés | MEDLINE | ID: mdl-30871982

RESUMEN

Dengue is a vector-transmitted viral infection that is a significant cause of morbidity and mortality in humans worldwide, with over 50 million apparent cases and a fatality rate of 2.5 % of 0.5 million severe cases per annum in recent years. Four serotypes are currently co-circulating. Diagnosis of infection may be by polymerase chain reaction, serology or rapid antigen test for NS1. Both pan-serotype and serotype-specific genome detection assays have been described, however, achieving adequate sensitivity with pan-serotype assays has been challenging. Indeed, as we show here, inspection of components and cycling parameters of a pan-serotype RT-qPCR assay in use in laboratories worldwide revealed insufficient probe stability to accommodate potential nucleotide mismatches, resulting in false-negatives. A minor-groove binder (MGB)-modified version of the probe was designed and its performance compared with that of the original probe in 32 samples. Eight of the samples were undetected by the original probe but detected by the MGB modified probe and six out of seven of these that could be serotyped belonged to serotype 4. Sequencing of the region targeted by the probe in these samples revealed two mismatches which were also universally present in all other serotype 4 sequences in a public database. We therefore recommend adoption of this MGB modification in order to reduce the risk of false-negative results, especially with dengue serotype 4 infections.


Asunto(s)
Sondas de ADN/genética , Virus del Dengue/aislamiento & purificación , Dengue/diagnóstico , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Sitios de Unión , Dengue/sangre , Reacciones Falso Negativas , Humanos , Hidrólisis , ARN Viral/sangre , Sensibilidad y Especificidad , Serogrupo
18.
Acta Neuropathol Commun ; 7(1): 45, 2019 03 18.
Artículo en Inglés | MEDLINE | ID: mdl-30885274

RESUMEN

Over the past two decades a number of studies have demonstrated activity of the retroviral enzyme reverse transcriptase in the serum of patients with sporadic amyotrophic lateral sclerosis (ALS). Known human exogenous retroviruses such as HIV-1 have been eliminated as possible sources of this activity and investigators have therefore considered the possibility that human endogenous retroviruses (HERVs) might be involved. HERV-K (HML-2) is the most recent retroviral candidate to be proposed following the observation of elevated HERV-K expression in cortical and spinal neurons of ALS patients and the demonstration of HERV-K envelope protein neurotoxicity in vitro and in transgenic mice. This retroviral hypothesis is an attractive one, not least because it raises the possibility that ALS might become treatable using antiretroviral drugs. In the present study we have attempted independent confirmation of the observation that HERV-K RNA levels are elevated in ALS brain. Total RNA was extracted from the postmortem premotor cortex of 34 patients with ALS and 23 controls. Quantitative real-time reverse transcription PCR (RT-qPCR) was performed according to the MIQE guidelines using HERV-K gag, pol and env primer sets. Data was analysed by the 2-∆∆Ct method with normalisation against two reference genes, GAPDH and XPNPEP1. Geometric mean HERV-K RNA expression levels in the premotor cortex of ALS patients were not found to be different from the expression levels in non-ALS controls. Our findings do not confirm the recently reported association between elevated cortical HERV-K RNA levels and ALS, and thus raise doubts about the role of this endogenous retrovirus in ALS pathogenesis. The results of this study may have implications for ongoing clinical trials aiming to suppress HERV-K activity with antiretroviral drugs.


Asunto(s)
Esclerosis Amiotrófica Lateral/metabolismo , Corteza Motora/metabolismo , ARN/biosíntesis , Proteínas Virales/biosíntesis , Anciano , Esclerosis Amiotrófica Lateral/genética , Esclerosis Amiotrófica Lateral/patología , Retrovirus Endógenos/genética , Retrovirus Endógenos/metabolismo , Femenino , Expresión Génica , Humanos , Masculino , Persona de Mediana Edad , Corteza Motora/patología , ARN/genética , Proteínas Virales/genética
19.
Open Forum Infect Dis ; 6(3): ofz048, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30882014

RESUMEN

BACKGROUND: Japanese encephalitis virus (JEV) is a leading cause of central nervous system (CNS) infections in Asia and results in significant morbidity and mortality. JEV RNA is rarely detected in serum or cerebrospinal fluid (CSF), and diagnosis of JEV infection is usually based on serological tests that are frequently difficult to interpret. Unlike serum or CSF, urine is relatively easy to obtain, but, to date, there has been minimal work on the feasibility of testing urine for JEV RNA. METHODS: We investigated the use of lysis buffer and a Microsep device to optimize urine storage for detection of JEV RNA by reverse transcription real-time polymerase chain reaction (RT-qPCR). The best of the studied methods was then evaluated in consecutive patients admitted to the hospital with suspected CNS infections in Laos. RESULTS: We demonstrated degradation of JEV RNA in urine after even short storage periods at 4°C or -80°C. Although there was no advantage in using a Microsep concentration device alone, immediate addition of lysis buffer to fresh urine improved the detection of JEV RNA at the limit of detection. CONCLUSIONS: In 2 studies of 41 patients with acute encephalitis syndrome, 11 (27%) were positive for JEV IgM in CSF and/or serum, and 2 (4.9%) were JEV RT-qPCR positive from throat swabs. JEV RNA was not detected in any of these patients' urine samples. However, lysis buffer was only used during a prospective study, that is, for only 17/41 (41%) patient urine samples. Our findings suggest a need for larger studies testing urine for JEV RNA, with urine collected at different times from symptom onset, and using lysis buffer, which stabilizes RNA, for storage.

20.
J Clin Microbiol ; 46(11): 3791-4, 2008 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-18701664

RESUMEN

Peripheral blood mononuclear cells are reported to be one of the extrahepatic replication sites contributing to the persistence of hepatitis C virus (HCV) infection. Whole-blood and plasma samples from 61 individuals were compared as sources for the detection of HCV RNA. Forty-four of the individuals were receiving antiviral therapy, while 17 were treatment naïve. The quantitation of HCV RNA was done by a sensitive in-house real-time reverse transcription-PCR. When the viral loads in the two types of samples were compared, a correlation coefficient of 0.858 (P < 0.001) was found, indicating that plasma and whole blood are equally acceptable sources for testing for HCV RNA.


Asunto(s)
Sangre/virología , Hepacivirus/aislamiento & purificación , ARN Viral/aislamiento & purificación , Carga Viral/métodos , Adolescente , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Plasma/virología , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa/métodos , Estadística como Asunto
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA