Eur Heart J ; 42(46): 4731-4739, 2021 12 07.
Artículo en Inglés | MEDLINE | ID: mdl-34453840

RESUMEN

AIMS: In patients with atrial fibrillation (AF) and heart failure (HF), strict and regular rate control with atrioventricular junction ablation and biventricular pacemaker (Ablation + CRT) has been shown to be superior to pharmacological rate control in reducing HF hospitalizations. However, whether it also improves survival is unknown. METHODS AND RESULTS: In this international, open-label, blinded outcome trial, we randomly assigned patients with severely symptomatic permanent AF >6 months, narrow QRS (≤110 ms) and at least one HF hospitalization in the previous year to Ablation + CRT or to pharmacological rate control. We hypothesized that Ablation + CRT is superior in reducing the primary endpoint of all-cause mortality. A total of 133 patients were randomized. The mean age was 73 ± 10 years, and 62 (47%) were females. The trial was stopped for efficacy at interim analysis after a median of 29 months of follow-up per patient. The primary endpoint occurred in 7 patients (11%) in the Ablation + CRT arm and in 20 patients (29%) in the Drug arm [hazard ratio (HR) 0.26, 95% confidence interval (CI) 0.10-0.65; P = 0.004]. The estimated death rates at 2 years were 5% and 21%, respectively; at 4 years, 14% and 41%. The benefit of Ablation + CRT of all-cause mortality was similar in patients with ejection fraction (EF) ≤35% and in those with >35%. The secondary endpoint combining all-cause mortality or HF hospitalization was significantly lower in the Ablation + CRT arm [18 (29%) vs. 36 (51%); HR 0.40, 95% CI 0.22-0.73; P = 0.002]. CONCLUSIONS: Ablation + CRT was superior to pharmacological therapy in reducing mortality in patients with permanent AF and narrow QRS who were hospitalized for HF, irrespective of their baseline EF. STUDY REGISTRATION: ClinicalTrials.gov Identifier: NCT02137187.


Asunto(s)
Fibrilación Atrial , Terapia de Resincronización Cardíaca , Anciano , Anciano de 80 o más Años , Fibrilación Atrial/terapia , Humanos , Persona de Mediana Edad , Proyectos de Investigación
2.
Europace ; 22(6): 932-938, 2020 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-32330937

RESUMEN

AIMS: Cardiac resynchronization therapy (CRT) reduces morbidity and mortality in patients with heart failure (HF) and electrical dyssynchrony. The European Society of Cardiology (ESC) Guidelines provide evidence-based recommendations indicating optimal patient selection for CRT implantation in both the 2013 European Heart Rhythm Association (EHRA) and the 2016 Heart Failure Association (HFA) Guidelines. We assessed the adherence to guidelines and identified factors associated with guideline adherence. METHODS AND RESULTS: In 2016, the HFA and EHRA conducted the CRT Survey II in 42 ESC countries. The data collected were sufficient to evaluate adherence to guidelines in 8021 patients. Of these, 67% had a Class I guideline indication for CRT implantation, which was significantly correlated with female gender (1.70, P < 0.0001), age <75 years (1.55, P < 0.0001), non-ischaemic HF aetiology (1.22, P < 0.0001), and elective admission (1.87, P < 0.0001). A further 26% of implants had a Class IIa indication, 5% IIb and only 2% a contraindication to CRT-a Class III indication. Patients implanted under Level IIa indications were much more likely to have more comorbidities than patients implanted under Level I indications. However, there were large variations in guideline adherence between ESC countries. CONCLUSION: Implanters in ESC member states demonstrate a high degree of adherence to ESC guidelines with 98% of implants having a documented Class I, IIa or IIb indication. Cardiac resynchronization therapy implantation without a Class I indication was more likely in men, patients age ≥75 years, with HF of ischaemic origin and in patients admitted to hospital acutely.


Asunto(s)
Terapia de Resincronización Cardíaca , Cardiología , Insuficiencia Cardíaca , Anciano , Dispositivos de Terapia de Resincronización Cardíaca , Europa (Continente) , Femenino , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Humanos , Masculino , Resultado del Tratamiento
3.
Curr Opin Cardiol ; 33(1): 1-6, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-29045344

RESUMEN

PURPOSE OF REVIEW: Atrial fibrillation and heart failure are commonly encountered in current clinical practice. This review aims to revisit the complex interaction of these two common situations and the best treatment whenever both occurs, especially focusing on heart failure patients undergoing cardiac resynchronization therapy (CRT). RECENT FINDINGS: It has been recently confirmed that in patients undergoing cardiac resynchronization therapy, 100% biventricular pacing percentage should be pursued. Large observational studies confirmed that atrioventricular junction ablation is very often the only way to gain 100% biventricular pacing in atrial fibrillation. SUMMARY: On the basis of the recent observational extensive data, in patients presenting intermediate or elevated atrial tachycardia-atrial fibrillation burden, atrioventricular junction ablation may represent a fundamental tool to achieve full CRT delivery, thus, conferring marked improvements in global cardiac function, and by extension, in survival. Atrial fibrillation patients should not be excluded from CRT, provided that maximal biventricular pacing is warranted.


Asunto(s)
Antagonistas Adrenérgicos beta/uso terapéutico , Antiarrítmicos/uso terapéutico , Fibrilación Atrial/terapia , Nodo Atrioventricular/cirugía , Terapia de Resincronización Cardíaca/métodos , Ablación por Catéter/métodos , Insuficiencia Cardíaca/terapia , Amiodarona/uso terapéutico , Fibrilación Atrial/complicaciones , Digoxina/uso terapéutico , Insuficiencia Cardíaca/complicaciones , Humanos , Resultado del Tratamiento
6.
Europace ; 19(8): 1349-1356, 2017 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-27702861

RESUMEN

AIMS: Patients receiving cardiac resynchronization therapy defibrillators (CRT-Ds) are likely to undergo one or more device replacements, mainly for battery depletion. We assessed the economic impact of battery depletion on the overall cost of CRT-D treatment from the perspectives of the healthcare system and the hospital. We also compared devices of different generations and from different manufacturers in terms of therapy cost. METHODS AND RESULTS: We analysed data on 1792 CRT-Ds implanted in 1399 patients in 9 Italian centres. We calculated the replacement probability and the total therapy cost over 6 years, stratified by device generation and manufacturer. Public tariffs from diagnosis-related groups were used together with device prices and hospitalization costs. Generators were from 3 manufacturers: Boston Scientific (667, 37%), Medtronic (973, 54%), and St Jude Medical (152, 9%). The replacement probability at 6 years was 83 and 68% for earlier- and recent-generation devices, respectively. The need for replacement increased total therapy costs by more than 50% over the initial implantation cost for hospitals and by more than 30% for healthcare system. The improved longevity of recent-generation CRT-Ds reduced the therapy cost by ∼6% in both perspectives. Among recent-generation CRT-Ds, the replacement probability of devices from different manufacturers ranged from 12 to 70%. Consequently, the maximum difference in therapy cost between manufacturers was 40% for hospitals and 19% for the healthcare system. CONCLUSIONS: Differences in CRT-D longevity strongly affect the overall therapy cost. While the use of recent-generation devices has reduced the cost, significant differences exist among currently available systems.


Asunto(s)
Dispositivos de Terapia de Resincronización Cardíaca/economía , Terapia de Resincronización Cardíaca/economía , Desfibriladores Implantables/economía , Remoción de Dispositivos/economía , Cardioversión Eléctrica/economía , Cardioversión Eléctrica/instrumentación , Suministros de Energía Eléctrica/economía , Costos de la Atención en Salud , Insuficiencia Cardíaca/economía , Insuficiencia Cardíaca/terapia , Ahorro de Costo , Análisis Costo-Beneficio , Bases de Datos Factuales , Cardioversión Eléctrica/efectos adversos , Diseño de Equipo , Falla de Equipo , Gastos en Salud , Insuficiencia Cardíaca/diagnóstico , Humanos , Italia , Modelos Económicos , Factores de Tiempo
7.
Europace ; 19(11): 1767-1775, 2017 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-28031277

RESUMEN

AIMS: To evaluate if the increased thromboembolic risk in female patients may be related to a higher burden of atrial fibrillation (AF). METHODS AND RESULTS: Data collected in a prospective observational research of patients implanted with a cardiac implantable electrical device (CIED) were analysed. We included 2398 patients: 489 (20.4%) were female and 1909 (79.6%) were male (oral anticoagulants treatment in 23.2%, independent of gender). During the follow-up (mean 42.8, median 37.7 months), 26 thromboembolic events occurred in 22 patients, with an incidence rate ratio of both stroke and stroke/transient ischemic attack (TIA) significantly higher in females compared with males [2.00, 95% confidence interval (CI) 1.53-2.61, P< 0.001 for stroke; 1.77 (95% C1.37-2.31, P< 0.001 for stroke/TIA]. An AF burden ≥5 min was a common finding (44% of patients), with no difference between men and women. The maximum daily AF burden and the time to evolution in permanent AF did not differ according to gender. The results of multivariate Cox regression showed that female gender, as well as history of CABG, were significant independent predictors of stroke and female gender was also an independent predictor of stroke/TIA. CONCLUSIONS: Among patients implanted with a CIED, an AF burden of at least 5 min is a common finding, (44% of patients). Female patients have a risk of stroke and TIAs that is around two-fold that of male patients, but this increased risk cannot be ascribed to a higher burden of AF or to differences in the evolution to permanent AF. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT01007474.


Asunto(s)
Fibrilación Atrial/epidemiología , Dispositivos de Terapia de Resincronización Cardíaca , Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Insuficiencia Cardíaca/terapia , Ataque Isquémico Transitorio/epidemiología , Accidente Cerebrovascular/epidemiología , Administración Oral , Anciano , Anticoagulantes/administración & dosificación , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/tratamiento farmacológico , Terapia de Resincronización Cardíaca/efectos adversos , Dispositivos de Terapia de Resincronización Cardíaca/efectos adversos , Distribución de Chi-Cuadrado , Puente de Arteria Coronaria/efectos adversos , Desfibriladores Implantables/efectos adversos , Cardioversión Eléctrica/efectos adversos , Femenino , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/epidemiología , Humanos , Incidencia , Ataque Isquémico Transitorio/diagnóstico , Ataque Isquémico Transitorio/prevención & control , Italia/epidemiología , Estimación de Kaplan-Meier , Persona de Mediana Edad , Análisis Multivariante , Modelos de Riesgos Proporcionales , Estudios Prospectivos , Medición de Riesgo , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores Sexuales , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/prevención & control , Factores de Tiempo
9.
Heart Fail Clin ; 13(1): 193-198, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-27886923

RESUMEN

Cardiac resynchronization therapy (CRT) is a device-based, nonpharmacologic approach that has shown to improve the outcome in patients with heart failure in terms of mortality and morbidity reduction. Large randomized trials have virtually enrolled patients in New York Heart Association class III-IV, with reduced left ventricular ejection fraction, with evidence of electrical dyssynchrony, and receiving optimal medical therapy and who were in sinus rhythm. Guidelines remain imprecise as to defining differentiated approaches according to the forms of atrial fibrillation other than permanent. These recommendations remain unsupported by evidence derived from randomized controlled trials, which are much needed.


Asunto(s)
Fibrilación Atrial/cirugía , Nodo Atrioventricular/cirugía , Terapia de Resincronización Cardíaca/métodos , Insuficiencia Cardíaca/terapia , Técnicas de Ablación , Dispositivos de Terapia de Resincronización Cardíaca , Terapia Combinada , Comorbilidad , Medicina Basada en la Evidencia , Humanos , Guías de Práctica Clínica como Asunto , Ensayos Clínicos Controlados Aleatorios como Asunto , Tasa de Supervivencia , Resultado del Tratamiento
10.
Europace ; 18(11): 1719-1725, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27485577

RESUMEN

AIMS: A long-detection interval (LDI) (30/40 intervals) has been proved to be superior to a standard-detection interval (SDI) (18/24 intervals) in terms of reducing unnecessary implantable cardioverter defibrillator (ICD) therapies. To better evaluate the different impact of LDI and anti-tachycardia pacing (ATP) on reducing painful shocks, we assessed all treated episodes in the ADVANCE III trial. METHODS AND RESULTS: A total of 452 fast (200 ms < cycle length ≤ 320 ms) arrhythmic episodes were recorded: 284 in 138 patients in the SDI arm and 168 in 82 patients in the LDI arm (106/452 inappropriate detections). A total of 346 fast ventricular tachycardias (FVT) were detected in 169 patients: 208 in 105 patients with SDI and 138 in 64 patients with LDI. Setting LDI determined a significant reduction in appropriate but unnecessary therapies [208 in SDI vs. 138 in LDI; incidence rate ratio (IRR): 0.61 (95% CI 0.45-0.83), P = 0.002]. Anti-tachycardia pacing determined another 52% reduction in unnecessary shocks [208 in SDI with hypothetical shock-only programming vs. 66 in LDI with ATP; IRR: 0.37 (95% CI 0.25-0.53, P < 0.001)]. The efficacy of ATP in terminating FVT was 63% in SDI and 52% in LDI (P = 0.022). No difference in the safety profile (acceleration/degeneration and death/cardiovascular hospitalizations) was observed between the two groups. CONCLUSION: The combination of LDI and ATP during charging is extremely effective and significantly reduces appropriate but unnecessary therapies. The use of LDI alone yielded a 39% reduction in appropriate but unnecessary therapies; ATP on top of LDI determined another 52% reduction in unnecessary shocks. The strategy of associating ATP and LDI could be considered in the majority of ICD recipients.


Asunto(s)
Estimulación Cardíaca Artificial/métodos , Desfibriladores Implantables , Cardioversión Eléctrica/métodos , Taquicardia Ventricular/terapia , Anciano , Femenino , Humanos , Italia , Estimación de Kaplan-Meier , Modelos Logísticos , Masculino , Persona de Mediana Edad , Prevención Secundaria , Método Simple Ciego , Taquicardia Ventricular/diagnóstico , Resultado del Tratamiento
11.
Europace ; 18(9): 1391-8, 2016 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26826135

RESUMEN

AIMS: Implantable cardioverter defibrillators improve survival of patients at risk for ventricular arrhythmias, but inappropriate shocks occur in up to 30% of patients and have been associated with worse quality of life and prognosis. In heart failure patients with cardiac resynchronization therapy defibrillators (CRT-Ds), we evaluated whether a new generation of detection and discrimination algorithms reduces inappropriate shocks. METHODS AND RESULTS: We analysed 1983 Medtronic CRT-D patients (80% male, 67 ± 10 years), 1368 with standard devices (Control CRT-D) and 615 with new generation devices (New CRT-D). Expert electrophysiologists reviewed and classified the electrograms of all device-detected ventricular tachycardia/fibrillation episodes. Total follow-up was 3751 patients-years. Incidence of inappropriate shocks at 1 year was 2.8% [95% confidence interval (CI) = 2.0-3.5] in Control CRT-D and 0.9% (CI = 0.4-2.2) in New CRT-D (hazard ratio = 0.37, CI = 0.21-0.66, P < 0.001). In New CRT-D, inappropriate shocks were reduced by 77% [incidence rate ratio (IRR) = 0.23, CI = 0.16-0.35, P < 0.001] and inappropriate anti-tachycardia pacing by 81% (IRR = 0.19, CI = 0.11-0.335, P < 0.001). Annual rate per 100 patient-years for appropriate VF detections was 3.0 (CI = 2.1-4.2) in New CRT-D and 3.2 (CI = 2.1-5.0) in Control CRT-D (P = 0.68), for syncope was 0.4 (CI = 0.2-0.9) in New CRT-D and 0.7 (CI = 0.5-1.0) in Control CRT-D (P = 0.266), and for death was 1.0 (CI = 0.6-1.6) in New CRT-D and 3.5 (CI = 3.0-4.1) in Control CRT-D (P < 0.001). CONCLUSION: Detection and discrimination algorithms used in new generation CRT-D significantly reduced inappropriate shocks when compared with standard CRT-D. This result, with no compromise on VF sensitivity or risk of syncope, has important implications for patients' quality of life and prognosis.


Asunto(s)
Algoritmos , Dispositivos de Terapia de Resincronización Cardíaca , Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Técnicas Electrofisiológicas Cardíacas , Insuficiencia Cardíaca/terapia , Falla de Prótesis , Procesamiento de Señales Asistido por Computador , Taquicardia Ventricular/prevención & control , Fibrilación Ventricular/prevención & control , Anciano , Terapia de Resincronización Cardíaca/efectos adversos , Bases de Datos Factuales , Cardioversión Eléctrica/efectos adversos , Femenino , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/fisiopatología , Humanos , Italia , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Análisis Multivariante , Valor Predictivo de las Pruebas , Puntaje de Propensión , Modelos de Riesgos Proporcionales , Estudios Prospectivos , Diseño de Prótesis , Factores de Riesgo , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatología , Factores de Tiempo , Resultado del Tratamiento , Fibrilación Ventricular/diagnóstico , Fibrilación Ventricular/fisiopatología
12.
Circulation ; 130(4): 308-14, 2014 Jul 22.
Artículo en Inglés | MEDLINE | ID: mdl-24838360

RESUMEN

BACKGROUND: Three trials demonstrated recently that a long detection window reduces implantable cardioverter-defibrillator (ICD) therapy in primary prevention patients. Avoid Delivering Therapies for Nonsustained Arrhythmias in ICD Patients III (ADVANCE III) was the only trial that enrolled both primary and secondary prevention patients. METHODS AND RESULTS: Of the 1902 patients enrolled in the ADVANCE III trial, 477 received a defibrillator for secondary prevention; 248 patients were randomly assigned to a long detection setting (30 of 40 intervals) and 229 to the nominal setting (18 of 24 intervals) for ventricular arrhythmias with cycle length ≤ 320 ms. Eight-five percent of patients were men, with a mean age of 65 ± 12 years, a previous history of ventricular fibrillation in 37% of the cases, and a mean ejection fraction of 38 ± 13%. The ICD device mix was 37% single chamber, 47% dual chamber, and 16% triple chamber. Over a median period of 12 months, the long detection period was associated with a 25% reduction in the number of overall therapies (115.6 versus 86.8 per 100 patient-years; incidence rate ratio, 0.75; 95% confidence interval, 0.61-0.93; P=0.008) and a 34% reduction in the number of shocks (rate per 100 patient-years, 51.2 versus 38.1; incidence rate ratio, 0.66; 95% confidence interval, 0.48-0.89; P=0.007). Appropriate therapies (89.7 versus 67.7; incidence rate ratio, 0.77; 95% confidence interval, 0.60-0.97; P=0.029) and appropriate shocks (37.1 versus 28.1; incidence rate ratio, 0.64; 95% confidence interval, 0.45-0.93; P=0.018) were also reduced. CONCLUSIONS: ADVANCE III is the first randomized trial to assess a long detection window setting in ICDs in both primary and secondary prevention populations and demonstrates a reduction of overall therapies and shocks in the subgroup of secondary prevention patients. These data suggest that even the secondary prevention population may benefit from programming that combines a long detection period with antitachycardia pacing during charging. CLINICAL TRIAL REGISTRATION URL: http://www/clinicaltrials.gov. Unique identifier: NCT00617175.


Asunto(s)
Desfibriladores Implantables , Cardioversión Eléctrica/métodos , Taquicardia Ventricular/prevención & control , Fibrilación Ventricular/prevención & control , Anciano , Muerte Súbita Cardíaca/prevención & control , Cardioversión Eléctrica/efectos adversos , Falla de Equipo , Femenino , Frecuencia Cardíaca , Hospitalización/estadística & datos numéricos , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Prevención Primaria , Prevención Secundaria , Método Simple Ciego , Volumen Sistólico , Síncope/epidemiología , Síncope/etiología , Taquicardia Ventricular/terapia , Factores de Tiempo , Fibrilación Ventricular/terapia
13.
Europace ; 17(8): 1251-8, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25976906

RESUMEN

AIMS: Device replacement at the time of battery depletion of implantable cardioverter-defibrillators (ICDs) may carry a considerable risk of complications and engenders costs for healthcare systems. Therefore, ICD device longevity is extremely important both from a clinical and economic standpoint. Cardiac resynchronization therapy defibrillators (CRT-D) battery longevity is shorter than ICDs. We determined the rate of replacements for battery depletion and we identified possible determinants of early depletion in a series of patients who had undergone implantation of CRT-D devices. METHODS AND RESULTS: We retrieved data on 1726 consecutive CRT-D systems implanted from January 2008 to March 2010 in nine centres. Five years after a successful CRT-D implantation procedure, 46% of devices were replaced due to battery depletion. The time to device replacement for battery depletion differed considerably among currently available CRT-D systems from different manufacturers, with rates of batteries still in service at 5 years ranging from 52 to 88% (log-rank test, P < 0.001). Left ventricular lead output and unipolar pacing configuration were independent determinants of early depletion [hazard ratio (HR): 1.96; 95% 95% confidence interval (CI): 1.57-2.46; P < 0.001 and HR: 1.58, 95% CI: 1.25-2.01; P < 0.001, respectively]. The implantation of a recent-generation device (HR: 0.57; 95% CI: 0.45-0.72; P < 0.001), the battery chemistry and the CRT-D manufacturer (HR: 0.64; 95% CI: 0.47-0.89; P = 0.008) were additional factors associated with replacement for battery depletion. CONCLUSION: The device longevity at 5 years was 54%. High left ventricular lead output and unipolar pacing configuration were associated with early battery depletion, while recent-generation CRT-Ds displayed better longevity. Significant differences emerged among currently available CRT-D systems from different manufacturers.


Asunto(s)
Desfibriladores Implantables/clasificación , Desfibriladores Implantables/estadística & datos numéricos , Remoción de Dispositivos/estadística & datos numéricos , Suministros de Energía Eléctrica/estadística & datos numéricos , Insuficiencia Cardíaca/prevención & control , Industrias/estadística & datos numéricos , Dispositivos de Terapia de Resincronización Cardíaca/clasificación , Dispositivos de Terapia de Resincronización Cardíaca/estadística & datos numéricos , Suministros de Energía Eléctrica/clasificación , Diseño de Equipo , Falla de Equipo , Análisis de Falla de Equipo/métodos , Análisis de Falla de Equipo/estadística & datos numéricos , Insuficiencia Cardíaca/epidemiología , Humanos , Italia/epidemiología , Evaluación de la Tecnología Biomédica/métodos , Evaluación de la Tecnología Biomédica/estadística & datos numéricos
14.
Europace ; 17(1): 137-41, 2015 01.
Artículo en Inglés | MEDLINE | ID: mdl-25414481

RESUMEN

The Cardiac Resynchronization Therapy (CRT) Survey II is a 6 months snapshot survey initiated by two ESC Associations, the European Heart Rhythm Association and the Heart Failure Association, which is designed to describe clinical practice regarding implantation of CRT devices in a broad sample of hospitals in 47 ESC member countries. The large volume of clinical and demographic data collected should reflect current patient selection, implantation, and follow-up practice and provide information relevant for assessing healthcare resource utilization in connection with CRT. The findings of this survey should permit representative benchmarking both nationally and internationally across Europe.


Asunto(s)
Terapia de Resincronización Cardíaca/estadística & datos numéricos , Terapia de Resincronización Cardíaca/normas , Insuficiencia Cardíaca/epidemiología , Insuficiencia Cardíaca/prevención & control , Pautas de la Práctica en Medicina/estadística & datos numéricos , Proyectos de Investigación , Anciano , Anciano de 80 o más Años , Europa (Continente) , Femenino , Adhesión a Directriz/estadística & datos numéricos , Humanos , Incidencia , Masculino , Guías de Práctica Clínica como Asunto , Factores de Riesgo , Resultado del Tratamiento
15.
Eur Heart J ; 35(8): 508-16, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24334432

RESUMEN

OBJECTIVE: The aim of this study was to assess the association between maximum daily atrial fibrillation (AF) burden and risk of ischaemic stroke. BACKGROUND: Cardiac implanted electronic devices (CIEDs) enhance detection of AF, providing a comprehensive measure of AF burden. DESIGN, SETTING, AND PATIENTS: A pooled analysis of individual patient data from five prospective studies was performed. Patients without permanent AF, previously implanted with CIEDs, were included if they had at least 3 months of follow-up. A total of 10 016 patients (median age 70 years) met these criteria. The risk of ischaemic stroke associated with pre-specified cut-off points of AF burden (5 min, 1, 6, 12, and 23 h, respectively) was assessed. RESULTS: During a median follow-up of 24 months, 43% of 10 016 patients experienced at least 1 day with at least 5 min of AF burden and for them the median time to the maximum AF burden was 6 months (inter-quartile range: 1.3-14). A Cox regression analysis adjusted for the CHADS2 score and anticoagulants at baseline demonstrated that AF burden was an independent predictor of ischaemic stroke. Among the thresholds of AF burden that we evaluated, 1 h was associated with the highest hazard ratio (HR) for ischaemic stroke, i.e. 2.11 (95% CI: 1.22-3.64, P = 0.008). CONCLUSIONS: Device-detected AF burden is associated with an increased risk of ischaemic stroke in a relatively unselected population of CIEDs patients. This finding may add to the basis for timely and clinically appropriate decision-making on anticoagulation treatment.


Asunto(s)
Fibrilación Atrial/diagnóstico , Fibrilación Atrial/terapia , Desfibriladores Implantables , Accidente Cerebrovascular/prevención & control , Anciano , Anticoagulantes/uso terapéutico , Costo de Enfermedad , Femenino , Humanos , Ataque Isquémico Transitorio/prevención & control , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Estudios Observacionales como Asunto , Estudios Prospectivos , Factores de Riesgo
16.
Am Heart J ; 167(2): 203-209.e1, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24439981

RESUMEN

BACKGROUND: In the major trials of cardiac resynchronization therapy (CRT), the survival benefit of the therapy, relative to control subjects, increases with QRS duration. In the non-CRT heart failure population, however, a wide QRS duration is associated with a shorter survival. Relative survival benefit from a therapy, however, is not synonymous with a longer absolute survival. We sought to determine whether baseline QRS duration relates to the absolute survival after CRT. METHODS AND RESULTS: In this prospective, longitudinal, observational study, 3,319 consecutive patients undergoing CRT (QRS 120-149 ms 26%, QRS 150-199 ms 58%, and QRS ≥200 ms 16%) were assessed in relation to mortality over 10 years. Overall mortality rates (per 100 patient-years) were 9.2%, 9.3%, and 13.3% in the 3 groups, respectively (all P < .001). Cardiac mortality rates were 6.2, 6.0, and 9.9 per 100 patient-years, respectively (all P < .001). Compared with the QRS 120-149 ms group, cardiac mortality was highest in the QRS ≥200 ms group (hazard ratio [HR] 1.72 [95% CI 1.35-2.19], P < .001), independent of age, gender, New York Heart Association class, presence of atrial fibrillation, heart failure etiology, and left ventricular ejection fraction. Median survival after CRT was longest in patients with a width of QRS 120-149 ms and shortest in patients with a QRS ≥200 ms (P < .001). In multivariable analyses, a QRS ≥200 ms emerged as a powerful independent predictor of both overall (HR 1.44 [95% CI 1.07-1.94], P = .017) and cardiac mortality (HR 1.59 [95% CI 1.14-2.24], P = .007). CONCLUSIONS: At long-term follow-up, absolute overall and cardiac survival after CRT is similar in patients with a preimplant QRS duration of 120 to 149 ms and 150 to 199 ms but markedly shorter in patients with a QRS ≥200 ms.


Asunto(s)
Terapia de Resincronización Cardíaca/métodos , Desfibriladores Implantables , Electrocardiografía , Insuficiencia Cardíaca/mortalidad , Anciano , Asia/epidemiología , Causas de Muerte/tendencias , Europa (Continente)/epidemiología , Femenino , Estudios de Seguimiento , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Humanos , Masculino , América del Norte/epidemiología , Estudios Prospectivos , Volumen Sistólico , Tasa de Supervivencia/tendencias , Factores de Tiempo , Resultado del Tratamiento , Función Ventricular Izquierda/fisiología
17.
Curr Opin Cardiol ; 28(1): 50-4, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23196776

RESUMEN

PURPOSE OF REVIEW: To describe the growing evidence that a maximal biventricular pacing is needed to gain the maximal benefits from cardiac resynchronization therapy (CRT). RECENT FINDINGS: Even small gains in the biventricular (BIV) pacing percentage are clinically important both to prevent acute heart failure and, more importantly, to improve survival. SUMMARY: Every effort should be made in all patients receiving CRT to approach 100% BIV pacing by a correct device programming, a correct pharmacologic regimen and atrioventricular nodal ablation in atrial fibrillation patients.


Asunto(s)
Fibrilación Atrial/terapia , Dispositivos de Terapia de Resincronización Cardíaca/normas , Terapia de Resincronización Cardíaca , Ablación por Catéter/métodos , Insuficiencia Cardíaca/terapia , Fibrilación Atrial/etiología , Fibrilación Atrial/fisiopatología , Nodo Atrioventricular/fisiopatología , Nodo Atrioventricular/cirugía , Terapia de Resincronización Cardíaca/métodos , Terapia de Resincronización Cardíaca/normas , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/fisiopatología , Humanos , Evaluación de Procesos y Resultados en Atención de Salud , Análisis de Supervivencia , Resultado del Tratamiento , Remodelación Ventricular
18.
Europace ; 15(9): 1273-9, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23439866

RESUMEN

AIMS: In candidates for cardiac resynchronization therapy (CRT), the choice between pacemaker (CRT-P) and defibrillator (CRT-D) implantation is still debated. We compared the long-term prognosis of patients who received CRT-D or CRT-P according to class IA recommendations of the European Society of Cardiology (ESC) and who were enrolled in a multicentre prospective registry. METHODS AND RESULTS: A total of 620 heart failure patients underwent successful implantation of a CRT device and were enrolled in the Contak Italian Registry. This analysis included 266 patients who received a CRT-D and 108 who received a CRT-P according to class IA ESC indications. Their survival status was verified after a median follow-up of 55 months. During follow-up, 73 CRT-D and 44 CRT-P patients died (rate 6.6 vs. 10.4%/year; log-rank test, P = 0.020). Patients receiving CRT-P were predominantly older, female, had no history of life-threatening ventricular arrhythmias, and more frequently presented non-ischaemic aetiology of heart failure, longer QRS durations, and worse renal function. However, the only independent predictor of death from any cause was the use of CRT-P (hazard ratio, 1.97; 95% confidence interval, 1.21-3.16; P = 0.007). CONCLUSION: The implantation of CRT-D, rather than CRT-P, may be preferable in patients presenting with current class IA ESC indications for CRT. Indeed, CRT-D resulted in greater long-term survival and was independently associated with a better prognosis.


Asunto(s)
Dispositivos de Terapia de Resincronización Cardíaca/estadística & datos numéricos , Terapia de Resincronización Cardíaca/mortalidad , Desfibriladores Implantables/estadística & datos numéricos , Cardioversión Eléctrica/mortalidad , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/prevención & control , Distribución por Edad , Supervivencia sin Enfermedad , Femenino , Humanos , Italia/epidemiología , Masculino , Prevalencia , Pronóstico , Factores de Riesgo , Distribución por Sexo , Tasa de Supervivencia , Sobrevivientes/estadística & datos numéricos , Resultado del Tratamiento
19.
JAMA ; 309(18): 1903-11, 2013 May 08.
Artículo en Inglés | MEDLINE | ID: mdl-23652522

RESUMEN

IMPORTANCE: Using more intervals to detect ventricular tachyarrhythmias has been associated with reducing unnecessary implantable cardioverter-defibrillator (ICD) therapies. OBJECTIVE: To determine whether using 30 of 40 intervals to detect ventricular arrhythmias (VT) (long detection) during spontaneous fast VT episodes reduces antitachycardia pacing (ATP) and shock delivery more than 18 of 24 intervals (standard detection). DESIGN, SETTING, AND PARTICIPANTS: Randomized, single-blind, parallel-group trial that enrolled 1902 primary and secondary prevention patients (mean [SD] age, 65 [11] years; 84% men; 75% primary prevention ICD) with ischemic and nonischemic etiology undergoing first ICD implant at 1 of 94 international centers (March 2008-December 2010). INTERVENTIONS: Patients were randomized 1:1 to programming with long- (n = 948) or standard-detection (n = 954) intervals. MAIN OUTCOMES AND MEASURES: Total number of ATPs and shocks delivered for all episodes (primary outcomes) and inappropriate shocks, mortality, and syncopal rate (secondary outcomes). RESULTS: During a median follow-up of 12 months (interquartile range, 11-13), long-detection group had 346 delivered therapies (42 therapies per 100 person-years, 95% CI, 38-47) vs 557 in the standard-detection group (67 therapies per 100 person-years [95% CI, 62-73]; incident rate ratio [IRR], 0.63 [95% CI, 0.51-0.78]; P < .001). The long- vs the standard-detection group experienced 23 ATPs per 100 person-years (95% CI, 20-27) vs 37 ATPs per 100 person-years (95% CI, 33-41; IRR, 0.58 [95% CI, 0.47-0.72]; P < .001); 19 shocks per 100 person-years (95% CI, 16-22) vs 30 shocks per 100 person-years (95% CI, 26-34; IRR, 0.77 [95% CI, 0.59-1.01]; P = .06), with a significant difference in the probability of therapy occurrence (P < .001); and a reduction in first occurrence of inappropriate shock (5.1 per 100 patient-years [95% CI, 3.7-6.9] vs 11.6 [95% CI, 9.4-14.1]; IRR, 0.55 [95% CI, 0.36-0.85]; P = .008). Mortality (5.5 [95% CI, 4.0-7.2] vs 6.3 [95% CI, 4.8-8.2] per 100 patient-years; HR, 0.87; P = .50) and arrhythmic syncope rates (3.1 [95% CI, 2.6-4.6] vs 1.9 [95% CI, 1.1-3.1] per 100 patient-years; IRR, 1.60 [95% CI, 0.76-3.41]; P = .22) did not differ significantly between groups. CONCLUSIONS AND RELEVANCE: Among patients receiving an ICD, the use of a long- vs standard-detection interval resulted in a lower rate of ATP and shocks, and inappropriate shocks. This programming strategy may be an appropriate alternative. TRIAL REGISTRATION: clinicaltrials.gov Identifier: NCT00617175.


Asunto(s)
Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Desfibriladores Implantables/efectos adversos , Cardioversión Eléctrica/métodos , Anciano , Algoritmos , Arritmias Cardíacas/mortalidad , Estimulación Cardíaca Artificial , Femenino , Hospitalización/estadística & datos numéricos , Humanos , Masculino , Persona de Mediana Edad , Isquemia Miocárdica/complicaciones , Prevención Primaria , Calidad de Vida , Prevención Secundaria , Método Simple Ciego , Factores de Tiempo , Resultado del Tratamiento
20.
Circulation ; 123(22): 2526-35, 2011 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-21576653

RESUMEN

BACKGROUND: Long-term data on device-related untoward events in patients receiving defibrillators for resynchronization therapy (CRT-D) are lacking. We quantified the frequency of repeat invasive procedures and the nature of long-term complications in current clinical practice and examined possible predictors of device-related events and their association with long-term patient outcome. METHODS AND RESULTS: We analyzed data from 3253 patients who underwent de novo successful implantation of CRT-D and were followed up for a median of 18 months (25th to 75th percentiles: 9 to 30) in 117 Italian centers. Device-related events were reported in 416 patients, and, specifically, surgical interventions for system revision were described in 390 patients. Four years after the implantation procedure, 50% of patients underwent surgical revision for battery depletion and 14% for unanticipated events. For comparison, at 4 years battery depletion occurred in 10% and 13% of patients who received single- and dual-chamber defibrillators at the study centers, and unanticipated events were reported as 4% and 9%, respectively. In CRT-D, infections occurred at a rate of 1.0%/y, and the risk of infections increased after device replacement procedures (hazard ratio, 2.04; 95% confidence interval, 1.01 to 4.09; P=0.045). Left ventricular lead dislodgements were reported at a rate of 2.3%/y and were predicted by longer fluoroscopy time and higher pacing threshold on implantation. Device-related events were not associated with a worse clinical outcome; indeed, the risk of death was similar in patients with and without surgical revision (hazard ratio, 0.90; 95% confidence interval, 0.56 to 1.47; P=0.682). CONCLUSIONS: In current clinical practice device-related events are more frequent in CRT-D than in single- or dual-chamber defibrillators, and are frequently managed by surgical intervention for system revision. However, a worse clinical outcome is not associated with these events. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT01007474.


Asunto(s)
Terapia de Resincronización Cardíaca/efectos adversos , Bases de Datos Factuales , Desfibriladores Implantables/efectos adversos , Complicaciones Posoperatorias/mortalidad , Reoperación/mortalidad , Reoperación/tendencias , Anciano , Femenino , Estudios de Seguimiento , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/terapia , Humanos , Italia , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/etiología , Tasa de Supervivencia/tendencias , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS