Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Clin Orthop Relat Res ; 471(7): 2312-7, 2013 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-23504538

RESUMEN

BACKGROUND: Recurrence rates for toe deformity correction are high and primarily are attributable to scar contractures. These contractures may result from subclinical infection. QUESTIONS/PURPOSES: We hypothesized that (1) recurrence of toe deformities and residual pain are related to low-grade infections from biofilm formation on percutaneous K wires, (2) biofilm formation is lower on titanium (Ti) K wires compared with stainless steel (SS) K wires, and (3) clinical outcome is superior with the use of Ti K wires compared with SS K wires. METHODS: In this prospective nonrandomized, comparative study, we investigated 135 lesser toe deformities (61 patients; 49 women; mean ± SD age, 60 ± 15 years) temporarily fixed with K wires between August 2010 and March 2011 (81 SS, 54 Ti). K wires were removed after 6 weeks. The presence of biofilm-related infections was analyzed by sonication. RESULTS: High bacterial loads (> 500 colony-forming units [CFU]/mL) were detected on all six toes requiring revision before 6 months. Increased bacterial load was associated with pain and swelling but not recurrence of the deformity. More SS K wires had greater than 100 CFU/mL bacteria than Ti K wires. For K wires with a bacterial count greater than 100 CFU/mL, toes with Ti K wires had a lower recurrence rate, less pain, and less swelling than toes with SS K wires. CONCLUSIONS: Ti K wires showed superior clinical outcomes to SS K wires. This appears to be attributable to reduced infection rates. Although additional study is needed, we currently recommend the use of Ti K wires for the transfixation of toe deformities. LEVEL OF EVIDENCE: Level II, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.


Asunto(s)
Biopelículas , Hilos Ortopédicos/efectos adversos , Deformidades del Pie/cirugía , Procedimientos Ortopédicos/instrumentación , Infecciones Relacionadas con Prótesis/prevención & control , Acero Inoxidable , Titanio , Falanges de los Dedos del Pie/cirugía , Anciano , Carga Bacteriana , Hilos Ortopédicos/microbiología , Ensayo de Unidades Formadoras de Colonias , Femenino , Humanos , Masculino , Persona de Mediana Edad , Procedimientos Ortopédicos/efectos adversos , Dolor Postoperatorio/etiología , Estudios Prospectivos , Diseño de Prótesis , Infecciones Relacionadas con Prótesis/microbiología , Recurrencia , Factores de Tiempo , Resultado del Tratamiento
2.
Acta Orthop ; 84(4): 353-9, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23799347

RESUMEN

Background and purpose Even small differences in design variables for the femoral stem may influence the outcome of a hip arthroplasty. We performed a risk factor analysis for aseptic loosening of 4 different versions of cemented Müller-type straight stems with special emphasis on design modifications (2 shapes, MSS or SL, and 2 materials, CoNiCrMo (Co) or Ti-6Al-7Nb (Ti)). Methods We investigated 828 total hip replacements, which were followed prospectively in our in-house register. All stems were operated in the same setup, using Sulfix-6 bone cement and a second-generation cementing technique. Demographic and design-specific risk factors were analyzed using an adjusted Cox regression model. Results The 4 versions showed marked differences in 15-year stem survival with aseptic loosening as the endpoint: 94% (95% CI: 89-99) for MSS Co, 83% (CI: 75-91) for SL Co, 81% (CI: 76-87) for MSS Ti and 63% (CI: 56-71) for SL Ti. Cox regression analysis showed a relative risk (RR) for aseptic loosening of 3 (CI: 2-5) for stems made of Ti and of 2 (CI: 1-2) for the SL design. The RR for aseptic stem loosening increased to 8 (CI: 4-15) when comparing the most and the least successful designs (MSS Co and SL Ti). Interpretation Cemented Müller-type straight stems should be MSS-shaped and made of a material with high flexural strength (e.g. cobalt-chrome). The surface finish should be polished (Ra < 0.4 µm). These technical aspects combined with modern cementing techniques would improve the survival of Müller-type straight stems. This may be true for all types of cemented stems.


Asunto(s)
Artroplastia de Reemplazo de Cadera/métodos , Prótesis de Cadera/estadística & datos numéricos , Diseño de Prótesis/estadística & datos numéricos , Falla de Prótesis , Anciano , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/instrumentación , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Modelos de Riesgos Proporcionales , Estudios Prospectivos , Sistema de Registros , Medición de Riesgo , Factores de Riesgo , Resultado del Tratamiento
3.
Hip Int ; 24(4): 333-9, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24531937

RESUMEN

A spherical pressfit cup with a new ceramic liner was introduced in a clinical trial in order to improve range of motion and reduce wear induced problems. The early clinical and radiological outcome was assessed.In a prospective cohort study 181 hips received a seleXys TH+ cup (Mathys, Bettlach, Switzerland) in combination with a third generation ceramic liner (ceramys, Mathys, Bettlach, Switzerland). The Harris Hip Score (HHS), pain (VAS) and range of motion (ROM) were recorded, cup migration and inclination were measured. Experience of any noise was documented.Fourteen hips were radiologically loose, seven of them were revised. Two-year survival of the cup was 92% with radiological loosening as the endpoint. There was no correlation between head size and ROM, no patient had a dislocation. There were no ceramic fractures. Two patients experienced squeaking and three clicking at final follow-up.Reasons for loosening might have been multifactorial but the rate of failure was unacceptably high. The use of large heads did not improve the ROM and development of noise could not be prevented with the modern ceramic. We abandoned the use of this implant system.


Asunto(s)
Artroplastia de Reemplazo de Cadera/instrumentación , Cerámica , Prótesis de Cadera , Osteoartritis de la Cadera/cirugía , Adulto , Anciano , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Diseño de Prótesis , Falla de Prótesis
4.
Orthop Rev (Pavia) ; 5(4): e31, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-24416475

RESUMEN

A minimally invasive anterior approach (MIS) was compared to a standard lateral approach in primary total hip arthroplasty. Clinical and radiological outcomes were analyzed 6 weeks, 12 weeks, one year and two years after surgery. The duration of surgery was longer, mobility one week after surgery was better and time of hospitalization was shorter for minimally invasive-treated patients. They had less pain during movement, limping, better Harris Hip Score and satisfaction after 6 weeks, which remained after 12 weeks and 1 year, but not after two years. There were two deep infections in the MIS group. Radiological results were not affected. The infections might be a point of concern, but there were no other disadvantages of the MIS approach. In fact, early rehabilitation was facilitated and clinical results were improved. Our results encourage the continuous use of the MIS anterior approach instead of the lateral approach.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA