RESUMEN
This paper reports the first investigation of the inverse finite element method (iFEM) coupled with the genetic algorithm (GA) to optimize sensor placement models of plate/shell structures for their real-time and full-field deformation reconstruction. The primary goal was to reduce the number of sensors in the iFEM models while maintaining the high accuracy of the displacement results. Here, GA was combined with the four-node quadrilateral inverse-shell elements (iQS4) as the genes inherited through generations to define the optimum positions of a specified number of sensors. Initially, displacement monitoring of various plates with different boundary conditions under concentrated and distributed static/dynamic loads was conducted to investigate the performance of the coupled iFEM-GA method. One of these case studies was repeated for different initial populations and densities of sensors to evaluate their influence on the accuracy of the results. The results of the iFEM-GA algorithm indicate that an adequate number of individuals is essential to be assigned as the initial population during the optimization process to ensure diversity for the reproduction of the optimized sensor placement models and prevent the local optimum. In addition, practical optimization constraints were applied for each plate case study to demonstrate the realistic applicability of the implemented method by placing the available sensors at feasible sites. The iFEM-GA method's capability in structural dynamics was also investigated by shape sensing the plate subjected to different dynamic loadings. Furthermore, a clamped stiffened plate and a curved shell were also considered to assess the applicability of the proposed method for the shape sensing of complex structures. Remarkably, the outcomes of the iFEM-GA approach with the reduced number of sensors agreed well with those of the full-sensor counterpart for all of the plate/shell case studies. Hence, this study reveals the superior performance of the iFEM-GA method as a viable sensor placement strategy for the accurate shape sensing of engineering structures with only a few sensors.
Asunto(s)
Placas Óseas , Ingeniería , Humanos , Análisis de Elementos FinitosRESUMEN
The presence of metronidazole (MNZ) and acetaminophen (ACE) in aquatic environments has raised growing concerns regarding their potential impact on human health. Incorporating various patterns into a photocatalytic material is considered a critical approach to achieving enhanced photocatalytic efficiency in the photocatalysis process. In this study, WO3 nanoparticles, which were immobilized onto ferromagnetic multi-walled carbon nanotubes that were functionalized using (3-glycidyloxypropyl)trimethoxysilane (FMMWCNTs@GLYMO@WO3), exhibited remarkable efficiency in removing MNZ and ACE (93% and 97%) in only 15 min. In addition, the new visible-light FMMWCNTs@GLYMO@WO3 nanoparticles as a magnetically separable photocatalyst were characterized by Fourier transform infrared (FT-IR) spectroscopy, X-ray diffraction analysis (XRD), transmission electron microscopy (TEM), field emission scanning electron microscopy (FESEM), energy-dispersive X-ray spectroscopy (EDS), EDS-mapping, vibrating sample magnetometry (VSM), thermogravimetric analysis (TGA), diffuse reflectance spectroscopy (DRS), high-performance liquid chromatography (HPLC), and total organic carbon (TOC) due to detailed studies (morphological, structural, magnetic and optical properties) of the photocatalyst. In-depth spectroscopic and microscopic characterization of the newly developed ferromagnetic FMMWCNTs@GLYMO@WO3 (III) photocatalyst revealed a spherical morphology, with nanoparticle diameters averaging between 23 and 39 nm. Compared to conventional multiwall carbon nanotube and WO3 photocatalysts, FMMWCNTs@GLYMO@WO3 (III) demonstrated superior photocatalytic activity. Remarkably, it exhibited excellent reusability, maintaining its efficiency over a minimum of five cycles in the degradation of metronidazole (MNZ) and acetaminophen (ACE).
Asunto(s)
Acetaminofén , Metronidazol , Fotólisis , Tungsteno , Acetaminofén/química , Metronidazol/química , Tungsteno/química , Catálisis , Nanotubos de Carbono/química , Contaminantes Químicos del Agua/química , Óxidos/químicaRESUMEN
Herein, a new visible-light active exfoliated g-C3N4/γ-Fe2O3/ZnO yolk-shell nanoparticles (NPs) was synthesized as a magnetically separable photocatalyst. For an in-depth understanding of the magnetic photocatalyst's structural, morphological, and optical properties, the products were extensively characterized with FT-IR, XRD, TEM, HRTEM, FESEM, EDS, EDS-mapping, VSM, DRS, EIS, and photocurrent. The photocatalyst was then utilized to degrade Levofloxacin (LEVO) and Indigo Carmine (IC) by visible light at room temperature. The exfoliated g-C3N4/γ-Fe2O3/ZnO yolk-shell NPs photocatalyst revealed 80% and 95.6% degradation efficiency for Levofloxacin and Indigo Carmine within 25 and 15 min, respectively. In addition, the optimal factors such as concentration, loading of photocatalyst, and pH were also assessed. Levofloxacin degradation mechanistic studies showed that electrons and holes significantly contribute to the photocatalytic process of photocatalyst degradation. In addition, after 5 times regeneration, exfoliated g-C3N4/γ-Fe2O3/ZnO yolk-shell NPs remained as an excellent magnetic photocatalyst for the eco-friendly degradation of Levofloxacin and Indigo Carmine (76% and 90%), respectively. The superior photocatalytic performance of exfoliated g-C3N4/γ-Fe2O3/ZnO yolk-shell nanoparticles (NPs) was mostly ascribed to the synergistic advantages of stronger visible light response, larger specific surface area, and the more effective separation and transfer of photogenerated charge carriers. Based on these results, the highly effective magnetic photocatalyst achieved better results than numerous studied catalysts in the literature. The degradation of Levofloxacin and Indigo Carmine under environmentally friendly conditions can be achieved using exfoliated g-C3N4/γ-Fe2O3/ZnO yolk-shell NPs (V) as an efficient and green photocatalyst. The magnetic photocatalyst was characterized by spectroscopic and microscopic methods, revealing a spherical shape and particle size of 23 nm. Additionally, the magnetic photocatalyst could be separated from the reaction mixture by a magnet without significantly reducing its catalytic activity.
Asunto(s)
Nanopartículas , Óxido de Zinc , Agua , Levofloxacino/química , Carmin de Índigo , Espectroscopía Infrarroja por Transformada de Fourier , CatálisisRESUMEN
INTRODUCTION: Although cuff leak test has been proposed as a simple method of predicting the occurrence of postextubation stridor, cut-off point of cuff-leak volume substantially differs between previous studies. In addition, laryngeal ultrasonography including measurement of air column width could predict postextubation stridor. The aim of the present study was to evaluate the value of laryngeal ultrasonography versus cuff leak test in predicting postextubation stridor. METHODS: In a prospective study, all patients intubated for a minimum of 24 h for acute respiratory failure, airway protection and other causes were included. Patients were evaluated for postextubation stridor and need for reintubation after extubation. The cuff leak volume was defined as a difference between expiratory tidal volumes with the cuff inflated and deflated. Laryngeal air column width was defined as the width of air passed through the vocal cords as determined by laryngeal ultrasonography. The air-column width difference was the width difference between balloon-cuff inflation and deflation. RESULTS: Forty one intubated patients with the mean age of 57.16±20.07 years were included. Postextubation stridor was observed in 4 patients (9.75%). Cuff leak test (cut off point: 249 mL) showed sensitivity and specificity of 75% and 59%, respectively. In addition, laryngeal ultrasonography (cut off point for air column width: 10.95 mm) resulted in sensitivity and specificity of 50% and 54%, respectively. Positive predictive value of both methods were <20%. CONCLUSION: Both cuff leak test and laryngeal ultrasonography have low positive predictive value and sensitivity in predicting postextubation stridor and should be used with caution in this regard.