Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros

Banco de datos
Tipo de estudio
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
J Infect Dis ; 207(11): 1694-702, 2013 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-23460751

RESUMEN

BACKGROUND: The long-term impact of allogeneic hematopoietic stem cell transplantation (HSCT) on human immunodeficiency virus type 1 (HIV-1) reservoirs in patients receiving combination antiretroviral therapy (cART) is largely unknown. METHODS: We studied the effects of a reduced-intensity conditioning allogeneic HSCT from donors with wild-type-CCR5(+) cells on HIV-1 peripheral blood reservoirs in 2 patients heterozygous for the ccr5Δ32 mutation. In-depth analyses of the HIV-1 reservoir size in peripheral blood, coreceptor use, and specific antibody responses were performed on samples obtained before and up to 3.5 years after HSCT receipt. RESULTS: Although HIV-1 DNA was readily detected in peripheral blood mononuclear cells (PBMCs) before and 2-3 months after HSCT receipt, HIV-1 DNA and RNA were undetectable in PBMCs, CD4(+) T cells, or plasma up to 21 and 42 months after HSCT. The loss of detectable HIV-1 correlated temporally with full donor chimerism, development of graft-versus-host disease, and decreases in HIV-specific antibody levels. CONCLUSIONS: The ability of donor cells to engraft without evidence of ongoing HIV-1 infection suggests that HIV-1 replication may be fully suppressed during cART and does not contribute to maintenance of viral reservoirs in peripheral blood in our patients. HSCTs with wild-type-CCR5(+) donor cells can lead to a sustained reduction in the size of the peripheral reservoir of HIV-1.


Asunto(s)
Infecciones por VIH/virología , VIH-1/aislamiento & purificación , Trasplante de Células Madre , Trasplante Homólogo , Carga Viral , Antirretrovirales/administración & dosificación , Terapia Antirretroviral Altamente Activa/métodos , Eliminación de Gen , Infecciones por VIH/tratamiento farmacológico , VIH-1/patogenicidad , Heterocigoto , Humanos , Masculino , Receptores CCR5/genética , Receptores CCR5/metabolismo , Receptores del VIH/genética , Receptores del VIH/metabolismo
2.
Small ; 9(15): 2553-63, 2478, 2013 Aug 12.
Artículo en Inglés | MEDLINE | ID: mdl-23447456

RESUMEN

Development of portable biosensors has broad applications in environmental monitoring, clinical diagnosis, public health, and homeland security. There is an unmet need for pathogen detection at the point-of-care (POC) using a fast, sensitive, inexpensive, and easy-to-use method that does not require complex infrastructure and well-trained technicians. For instance, detection of Human Immunodeficiency Virus (HIV-1) at acute infection stage has been challenging, since current antibody-based POC technologies are not effective due to low concentration of antibodies. In this study, we demonstrated for the first time a label-free electrical sensing method that can detect lysed viruses, i.e. viral nano-lysate, through impedance analysis, offering an alternative technology to the antibody-based methods such as dipsticks and Enzyme-linked Immunosorbent Assay (ELISA). The presented method is a broadly applicable platform technology that can potentially be adapted to detect multiple pathogens utilizing impedance spectroscopy for other infectious diseases including herpes, influenza, hepatitis, pox, malaria, and tuberculosis. The presented method offers a rapid and portable tool that can be used as a detection technology at the POC in resource-constrained settings, as well as hospital and primary care settings.


Asunto(s)
Técnicas Biosensibles/métodos , Electricidad , VIH-1/aislamiento & purificación , Dispositivos Laboratorio en un Chip , Nanopartículas/química , Coloración y Etiquetado , Espectroscopía Dieléctrica , Fluorescencia , Humanos , Fenómenos Magnéticos
3.
Sci Rep ; 4: 3796, 2014 Jan 22.
Artículo en Inglés | MEDLINE | ID: mdl-24448112

RESUMEN

HIV has become one of the most devastating pathogens in human history. Despite fast progress in HIV-related basic research, antiretroviral therapy (ART) remains the most effective method to save AIDS patients' lives. Unfortunately, ART cannot be universally accessed, especially in developing countries, due to the lack of effective treatment monitoring diagnostics. Here, we present an inexpensive, rapid and portable micro-a-fluidic platform, which can streamline the process of an enzyme-linked immunosorbent assay (ELISA) in a fully automated manner for CD4 cell count. The micro-a-fluidic CD4 cell count is achieved by eliminating operational fluid flow via "moving the substrate", as opposed to "flowing liquid" in traditional ELISA or microfluidic methods. This is the first demonstration of capturing and detecting cells from unprocessed whole blood using the enzyme-linked immunosorbent assay (ELISA) in a microfluidic channel. Combined with cell phone imaging, the presented micro-a-fluidic ELISA platform holds great promise for offering rapid CD4 cell count to scale up much needed ART in resource-constrained settings. The developed system can be extended to multiple areas for ELISA-related assays.


Asunto(s)
Linfocitos T CD4-Positivos/inmunología , Ensayo de Inmunoadsorción Enzimática/métodos , Infecciones por VIH/sangre , Infecciones por VIH/diagnóstico , Microfluídica/instrumentación , Microfluídica/métodos , Sistemas de Atención de Punto , Recuento de Linfocito CD4 , Linfocitos T CD4-Positivos/virología , Teléfono Celular , Citometría de Flujo , Infecciones por VIH/inmunología , Infecciones por VIH/virología , VIH-1/patogenicidad , Humanos , Carga Viral
4.
Int J Nanomedicine ; 7: 5019-28, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-23055720

RESUMEN

Sample preparation is a significant challenge for detection and sensing technologies, since the presence of blood cells can interfere with the accuracy and reliability of virus detection at the nanoscale for point-of-care testing. To the best of our knowledge, there is not an existing on-chip virus isolation technology that does not use complex fluidic pumps. Here, we presented a lab-on-a-chip filter device to isolate plasma and viruses from unprocessed whole blood based on size exclusion without using a micropump. We demonstrated that viruses (eg, HIV) can be separated on a filter-based chip (2-µm pore size) from HIV-spiked whole blood at high recovery efficiencies of 89.9% ± 5.0%, 80.5% ± 4.3%, and 78.2% ± 3.8%, for viral loads of 1000, 10,000 and 100,000 copies/mL, respectively. Meanwhile, 81.7% ± 6.7% of red blood cells and 89.5% ± 2.4% of white blood cells were retained on 2 µm pore-sized filter microchips. We also tested these filter microchips with seven HIV-infected patient samples and observed recovery efficiencies ranging from 73.1% ± 8.3% to 82.5% ± 4.1%. These results are first steps towards developing disposable point-of-care diagnostics and monitoring devices for resource-constrained settings, as well as hospital and primary care settings.


Asunto(s)
Eliminación de Componentes Sanguíneos/instrumentación , VIH/aislamiento & purificación , Análisis por Micromatrices/instrumentación , Nanotecnología/instrumentación , Plasma/virología , Ultrafiltración/instrumentación , Virus/aislamiento & purificación , Diseño de Equipo , Análisis de Falla de Equipo , Humanos
5.
Proc SPIE Int Soc Opt Eng ; 7666: 76661H, 2010 May 05.
Artículo en Inglés | MEDLINE | ID: mdl-24478824

RESUMEN

The World Health Organization (WHO) is rapidly expanding antiretroviral treatment (ART) in sub-Saharan countries. However, virological failure of ART is rarely monitored due to the lack of affordable and sustainable viral load assays suitable for resource-limited settings. Here, we report a prototype of a rapid virus detection method based on microfluidic technologies. In this method, HIV-1 particles from 10 µL whole blood were captured by anti-gp120 antibody coated on the microchannel surface and detected by dual fluorescence signals under microscopy. Next, captured HIV-1 particles were counted using the free software, ImageJ (http://rsbweb.nih.gov/ij/). This rapid HIV-1 detection method has potential to be further developed for viral load monitoring at resource-limited settings.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA