Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 74
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Int Orthop ; 46(5): 989-997, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35113185

RESUMEN

INTRODUCTION: Total hip arthroplasty (THA) in young adults, especially in those with hip dysplasia, is affected by wear and acetabular fixation problems. Shelf acetabuloplasty is performed to delay THA in patients with acetabular dysplasia. Thus, we conducted a retrospective, continuous case-control study at a single healthcare facility to analyze (1) the influence of prior shelf acetabuloplasty on the survival of a subsequent THA and (2) the functional outcomes. MATERIALS AND METHODS: We evaluated 105 patients (124 THA) who underwent THA due to hip dysplasia: 54 patients (61 THA) were included in the THA post-shelf acetabuloplasty group (case group) and 51 patients (63 THA) in the THA for dysplasia group (control group). RESULTS: At 15 years' follow-up, 89% of patients (95% CI: 84-91%) in the shelf group and 83% (95% CI: 81-90%) in the dysplasia group had not undergone surgical revision. This difference between groups was not statistically significant (p = 0.566). The functional outcomes were satisfactory in both groups; however, they were significantly better in the dysplasia group than in the shelf group based on the Merle d'Aubigne and Postel score (16.9 vs 16.0 min-max: 14-18 vs 3-18) (p = 0.01), Harris Hip score (90.0 vs 84.7, min-max: 62-100 vs 22-100) (p = 0.017), and the Oxford-12 (18/60 vs 21/60, min-max: 45-12 vs 51-12) (p = 0.04). CONCLUSION: Shelf acetabuloplasty before THA does not negatively affect THA survivorship. The functional outcomes appear to be better in the hips that did not undergo shelf acetabuloplasty, although the results were good in both groups.


Asunto(s)
Acetabuloplastia , Artroplastia de Reemplazo de Cadera , Luxación Congénita de la Cadera , Luxación de la Cadera , Artroplastia de Reemplazo de Cadera/efectos adversos , Estudios de Casos y Controles , Estudios de Seguimiento , Luxación de la Cadera/cirugía , Luxación Congénita de la Cadera/cirugía , Articulación de la Cadera/cirugía , Humanos , Reoperación , Estudios Retrospectivos , Resultado del Tratamiento , Adulto Joven
2.
Int Orthop ; 46(12): 2799-2806, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-35960343

RESUMEN

INTRODUCTION: The management of prosthetic joint infection (PJI) has been widely studied in the context of total hip arthroplasty (THA). However, the outcomes of debridement, antibiotics and implant retention (DAIR) for PJI have never been compared between hip resurfacing arthroplasty (HRA) and THA. This led us to carry out a retrospective case-control study comparing the surgical treatment of post-operative infections between HRA and THA to determine the infection remission rate and the medium-term functional outcomes. METHODS: This single-centre case-control study analysed 3056 HRA cases of which 13 patients had a PJI treated by DAIR. These patients were age-matched with 15 infected THA hips treated by DAIR and modular component exchange (controls). Their survival (no recurrence of the infection) was compared and factors that could affect the success of the DAIR were explored: sex, body mass index, age at surgery, presence of haematoma, type of bacteria present and antibiotic therapy. RESULTS: At a mean follow-up of five years (2-7), the infection control rate was significantly higher in the HRA group (100% [13/13]) than in the THA group (67% [10/15]) (p = 0.044). More patients in the THA group had undergone early DAIR (< 30 days) (73% [11/15]) than in the HRA group (54% [7/13]). There was no significant difference between the two groups in the ASA score, presence of comorbidities, body mass index and duration of the initial arthroplasty procedure. At the review, the Oxford-12 score of 17/60 (12-28) was better in the HRA group than the score of 25/60 (12-40) in the THA group (p = 0.004). CONCLUSION: DAIR, no matter the time frame, is a viable therapeutic option for infection control after HRA.


Asunto(s)
Artritis Infecciosa , Artroplastia de Reemplazo de Cadera , Humanos , Artroplastia de Reemplazo de Cadera/efectos adversos , Antibacterianos/uso terapéutico , Estudios de Casos y Controles , Desbridamiento , Estudios Retrospectivos
3.
Nature ; 526(7572): 230-2, 2015 Oct 08.
Artículo en Inglés | MEDLINE | ID: mdl-26450055

RESUMEN

In the 1980s, excess infrared emission was discovered around main-sequence stars; subsequent direct-imaging observations revealed orbiting disks of cold dust to be the source. These 'debris disks' were thought to be by-products of planet formation because they often exhibited morphological and brightness asymmetries that may result from gravitational perturbation by planets. This was proved to be true for the ß Pictoris system, in which the known planet generates an observable warp in the disk. The nearby, young, unusually active late-type star AU Microscopii hosts a well-studied edge-on debris disk; earlier observations in the visible and near-infrared found asymmetric localized structures in the form of intensity variations along the midplane of the disk beyond a distance of 20 astronomical units. Here we report high-contrast imaging that reveals a series of five large-scale features in the southeast side of the disk, at projected separations of 10-60 astronomical units, persisting over intervals of 1-4 years. All these features appear to move away from the star at projected speeds of 4-10 kilometres per second, suggesting highly eccentric or unbound trajectories if they are associated with physical entities. The origin, localization, morphology and rapid evolution of these features are difficult to reconcile with current theories.

4.
Clin Orthop Relat Res ; 479(7): 1534-1544, 2021 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-34128911

RESUMEN

BACKGROUND: Patient-reported outcome measures such as the Oxford-12 Hip Score and Hip Disability and Osteoarthritis Outcome Score (HOOS) are used in daily orthopaedic practice to evaluate patients. Because different studies use different scores, it would be important to build conversion tables between scores (crosswalk) to compare the results of one study with those of another study. Various mapping methods can be used to develop crosswalk tables that convert Oxford-12 scores to the HOOS (and its derivatives, including the HOOS physical function short form, HOOS joint replacement, and HOOS-12) and vice versa. Although prior studies have investigated this issue, they are limited to short forms of the HOOS score. Consequently, they cannot be applied to hip preservation surgery and do not include quality-of-life items, whereas the Oxford-12 Hip Score is used for all hip evaluations. QUESTIONS/PURPOSES: We prospectively studied the Oxford-12 and HOOS and its derivatives to (1) determine which version of the HOOS has the best mapping with the Oxford-12, (2) define the most-appropriate mapping method using selected indicators, and (3) generate crosswalk tables between these two patient-reported outcome measures. METHODS: The study enrolled 500 adult patients before primary THA (59% men [294 of 500 patients]) with hip osteoarthritis or avascular necrosis of the femoral head who completed the HOOS and Oxford-12. Patients were recruited from January 2018 to September 2019 in a tertiary-care university hospital, and we included all primary THAs in patients older than 18 years with a BMI lower than 35 kg/m2 and greater than 18 kg/m2. After a minimum of 6 months of follow-up, 39% (195 of 500) of the patients were assessed using the same tools. To determine which version of the HOOS mapped best to the Oxford-12 and what the most-appropriate mapping method was, we used preoperative data from all 500 patients. Because there is no consensus on the method to establish crosswalk, various mapping methods (linear regression, tobit regression, and quantile regression) and equating methods (linear equating and equipercentile method) were applied along with cross-validation to determine which method was the most suitable and which form of the HOOS provided the best result according to different criteria (mean absolute error, r2, and Kolmogorov-Smirnov distance).To generate crosswalk tables, we created a conversion table (between the Oxford-12 and the HOOS form that was chosen after answering our first research question and the method chosen after answering our second question) using preoperative and postoperative data (n = 695). This table was meant to be simple to use and allows easy conversions from one scoring system to another. RESULTS: The Oxford-12 and HOOS were strongly correlated (Pearson correlation coefficient range 0.586-0.842) for the HOOS subcategories and HOOS physical function, HOOS joint replacement, and HOOS-12. The correlation between the HOOS-12 and Oxford-12 was the strongest (r = 0.825). According to the three different criteria and five methods, the HOOS-12 was the best suited for mapping. The goal was to minimize the mean absolute error (perfect model = 0), have a Kolmogorov-Smirnov distance as close as possible to 0, and have the r2 as close as possible to 1. Regarding the most-suitable method for the crosswalk mapping (research question 2), the five methods generated similar results for the r2 (range 0.63-0.67) and mean absolute error (range 6-6.2). For the Kolmogorov-Smirnov distance, the equipercentile method was the best (Kolmogorov-Smirnov distance 0.04), with distance reduced by 43% relative to the regression methods (Kolmogorov-Smirnov distance 0.07). A graphical comparison of the predicted and observed scores showed that the equipercentile method provided perfect superposition of predicted and observed values after mapping. Finally, crosswalk tables were produced between the HOOS-12 and Oxford-12. CONCLUSION: The HOOS-12 is the most complete and suitable form of the HOOS for mapping with the Oxford-12, while the equipercentile method is the most suitable for predicting values after mapping. This study provides clinicians with a reliable tool to crosswalk between these scores not only for joint arthroplasty but also for all types of hip surgeries while also assessing quality of life. Our findings should be confirmed in additional studies. CLINICAL RELEVANCE: The resulting crosswalk tables can be used in meta-analyses, systematic reviews, or clinical practice to compare clinical studies that did not include both outcome scores. In addition, with these tools, the clinician can collect only one score while still being able to compare his or her results with those obtained in other databases and registries, and to add his or her results to other databases and joint registries.


Asunto(s)
Artroplastia de Reemplazo de Cadera/estadística & datos numéricos , Evaluación de la Discapacidad , Necrosis de la Cabeza Femoral/cirugía , Osteoartritis de la Cadera/cirugía , Medición de Resultados Informados por el Paciente , Adulto , Anciano , Anciano de 80 o más Años , Correlación de Datos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Periodo Posoperatorio , Periodo Preoperatorio , Estudios Prospectivos , Calidad de Vida , Análisis de Regresión , Reproducibilidad de los Resultados , Índice de Severidad de la Enfermedad , Adulto Joven
5.
Nature ; 493(7431): 191-4, 2013 Jan 10.
Artículo en Inglés | MEDLINE | ID: mdl-23283173

RESUMEN

The formation of gaseous giant planets is thought to occur in the first few million years after stellar birth. Models predict that the process produces a deep gap in the dust component (shallower in the gas). Infrared observations of the disk around the young star HD 142527 (at a distance of about 140 parsecs from Earth) found an inner disk about 10 astronomical units (AU) in radius (1 AU is the Earth-Sun distance), surrounded by a particularly large gap and a disrupted outer disk beyond 140 AU. This disruption is indicative of a perturbing planetary-mass body at about 90 AU. Radio observations indicate that the bulk mass is molecular and lies in the outer disk, whose continuum emission has a horseshoe morphology. The high stellar accretion rate would deplete the inner disk in less than one year, and to sustain the observed accretion matter must therefore flow from the outer disk and cross the gap. In dynamical models, the putative protoplanets channel outer-disk material into gap-crossing bridges that feed stellar accretion through the inner disk. Here we report observations of diffuse CO gas inside the gap, with denser HCO(+) gas along gap-crossing filaments. The estimated flow rate of the gas is in the range of 7 × 10(-9) to 2 × 10(-7) solar masses per year, which is sufficient to maintain accretion onto the star at the present rate.

6.
Int Orthop ; 42(5): 1007-1013, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-28988365

RESUMEN

PURPOSE: The purpose of this study was to evaluate the outcomes of total hip arthroplasty (THA) revision with cementless stems using a numeric global radiological score (GRxS) that summarizes two previously validated scores: secondary bone stock (SBS) and osseointegration-secondary stability (O-SS). METHOD: One hundred fifty cases of THA were evaluated at a mean follow-up of 6.5 ± 3.7 years. The GRxS combines the SBS, which evaluated cortical bone thickness, bone density and bone defects in each Gruen zone and the O-SS, which evaluated the location and extent of a single radiolucent line. To calculate the GRxS, the SBS and O-SS were each expressed on a 10-point scale and given equal weighing. The final result was a number out of 20. The GRxS was used to assign a radiological grade to each THA case: very good (20), good (18-15), average (13-12), or poor (≤ 10). The numerical mean (Nm) was calculated for each grade. The inter- and intra-observer reproducibility was evaluated. RESULTS: The inter-observer reproducibility was good (0.8) and the intra-observer reproducibility was very good (0.9). The GRxS was considered very good in 46 cases (Nm 20), good in 57 cases (Nm 16.6), average in 25 cases and poor in 22 cases. There was a significant relationship between the GRxS and the Harris Hip and Postel Merle d'Aubigné scores (p < 0.0001), and the initial bone stock (p = 0.0001). CONCLUSIONS: The GRxS is reliable and reproducible. This information can be used by surgeons to adapt the surgical technique to bone characteristics (especially during revision cases) and to compare the outcomes of different implant designs.


Asunto(s)
Artroplastia de Reemplazo de Cadera/métodos , Fémur/cirugía , Articulación de la Cadera/cirugía , Prótesis de Cadera/efectos adversos , Reoperación/métodos , Adulto , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Cadera/efectos adversos , Densidad Ósea , Femenino , Fémur/diagnóstico por imagen , Estudios de Seguimiento , Articulación de la Cadera/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Oseointegración , Reproducibilidad de los Resultados , Resultado del Tratamiento
7.
J Arthroplasty ; 32(4): 1206-1210, 2017 04.
Artículo en Inglés | MEDLINE | ID: mdl-27988181

RESUMEN

BACKGROUND: Total hip arthroplasty with metal-on-metal (MoM) bearings has been suspected to cause adverse reactions to metal debris (ARMD), with the incidence varying greatly by implant type and patient gender. The prevalence of ARMD from small-diameter MoM bearings in women is unknown, especially after 10 years of follow-up (FU). METHODS: Cementless 28-mm MoM total hip arthroplasty bearings (Metasul) were implanted consecutively in 42 active women between 1996 and 2002. They were reviewed after a minimum of 10 years' FU with clinical, laboratory, radiological, and ultrasound assessments. RESULTS: Mean FU was 15.9 years (range, 13-18). The mean Postel-Merle d'Aubigné and Oxford scores were 16.9 (range, 13-18) and 15.1 (range, 12-24), respectively, at FU. Mean cup inclination angle was 46.3° (range, 35°-57°). No femoral osteolysis was detected, but limited acetabular osteolysis (11%) over the screw holes occurred in 5 cases. No liquid or solid synovial reactions or ARMD were apparent on ultrasound, even in the 5 cases of pelvic osteolysis. Mean chromium levels were 1.32 µg/L (range, 0.1-7.9) and cobalt levels were 1.85 µg/L (range, 0.35-13.6). Cobalt was >3 µg/L in only 3 cases. The 15.9-year survivorship was 95% (range, 94.1%-98.9%). CONCLUSION: Reliable results were obtained with 28-mm MoM bearings, notably in young, active patients. This implant configuration requires very accurate positioning. No ARMD was seen in this group at 16 years' FU.


Asunto(s)
Prótesis de Cadera/efectos adversos , Prótesis Articulares de Metal sobre Metal/efectos adversos , Metales/efectos adversos , Complicaciones Posoperatorias/epidemiología , Acetábulo/cirugía , Adolescente , Adulto , Artroplastia de Reemplazo de Cadera/efectos adversos , Cromo/sangre , Cobalto/sangre , Femenino , Fémur/cirugía , Estudios de Seguimiento , Humanos , Incidencia , Persona de Mediana Edad , Complicaciones Posoperatorias/sangre , Complicaciones Posoperatorias/diagnóstico por imagen , Complicaciones Posoperatorias/etiología , Prevalencia , Diseño de Prótesis , Radiografía , Reoperación , Estudios Retrospectivos , Tasa de Supervivencia , Factores de Tiempo , Resultado del Tratamiento , Ultrasonografía , Adulto Joven
8.
Int Orthop ; 41(12): 2503-2508, 2017 12.
Artículo en Inglés | MEDLINE | ID: mdl-28616704

RESUMEN

INTRODUCTION: Metal-on-metal (MoM) hip replacement bearings produce metallic ions that can cause health complications. Metallic release also occurs with other materials, but data on metallic ion levels after knee arthroplasty are sparse. We postulate that knee replacement generates elevating metallic ions (chromium (Cr), cobalt (Co) and titanium (Ti)) during the first year after implantation. PATIENTS AND METHODS: This ongoing prospective study included all patients who underwent the same type of knee arthroplasty between May and December 2013. Cr, Co and Ti levels were measured in whole blood at pre-operation and one-year follow-up (6 and 12 months). Clinical and radiographic data (range of motion, Oxford, International Knee Society (IKS) and satisfaction scores) were recorded. RESULTS: In 90 patients, preoperative Cr, Co and Ti metallic ion levels were respectively 0.45 µg/l, 0.22 µg/l, 2.94 µg/l and increased to 1.27 µg/l, 1.41 µg/l, 4.08 µg/l (p < 0.0001) at last one-year follow-up. Mean Oxford and IKS scores rose, respectively, from 45.9 (30-58) and 24.9 (12-52) to 88.3 (0-168) and 160.8 (93-200) (p < 0.001). CONCLUSION: After the implantation of knee arthroplasty, we found significant blood elevation of Cr, Co and Ti levels one year after implantation exceeding the normal values. This metallic ion release could lead to numerous effects: allergy, hypersensitivity, etc.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/efectos adversos , Cromo/sangre , Cobalto/sangre , Prótesis de la Rodilla/efectos adversos , Titanio/sangre , Adulto , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Rodilla/métodos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Diseño de Prótesis/efectos adversos
10.
Clin Orthop Relat Res ; 474(10): 2190-9, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-27255729

RESUMEN

BACKGROUND: Despite widespread use of ceramic-on-ceramic (CoC) in total hip arthroplasty (THA) during the past 10 years, little is known about why revisions are performed in hips with this bearing or the time elapsed before revision. QUESTIONS/PURPOSES: The purposes of this study were: (1) Do the reasons for first revision differ between CoC bearings and other bearing couples? (2) Does the time to revision differ between CoC and other bearing couples? (3) Are there unique reasons for revisions of CoC bearings? METHODS: All members of the Société Française de Chirurgie Orthopédique et Traumatologique (SoFCOT) who performed ≥ 30 revisions per year were invited to participate in this multicenter, prospective, observational study. Our data represent 12% of the revision procedures performed in France. A total of 2107 first revisions of THA (from January 2010 to December 2011) were done in 2107 patients (1201 females [57%] and 906 males [43%]; median age, 73 years; age range, 17-104 years) at the time of surgery after a median of 11 years (range, 0 day-42 years) after the primary THA. There were 238 of 2107 (11%) CoC, 148 of 2107 (7%) metal-on-metal (MoM), and 1721 of 2017 (82%) metal-on-polyethylene (MoP) bearings. RESULTS: The reasons for reoperation differed according to the bearing component: (1) for the MoP reference bearing (odds ratio [OR]; 95% confidence interval), cup loosening occurred in 698 of 1721 hips (41%), periprosthetic fracture in 220 of 1721 hips (13%), and osteolysis in 213 of 1721 hips (12%); (2) for CoC, cup loosening occurred in 41 of 238 hips (17%) (OR, 0.31 [0.22-0.43; p < 0.001), infection in 39 of 238 hips (16%) (OR, 1.63 [1.12-2.37]; p = 0.01), and dislocation in 23 of 238 hips (10%) (OR, 0.9 [0.57-1.42]; p = 0.9); (3) for MoM, cup loosening occurred in 28 of 148 hips (19%) (OR, 0.34 [0.22-0.52]; p < 0.001), adverse reaction to metallic debris in 26 of 148 hips (18%) (OR, 18.12 [9.84-33.4]; p < 0.001), and infection in 16 of 148 hips (11%) (OR, 1 [0.59-1.73]; p = 0.9). In comparison with MoP, osteolysis was rarely the reason for revision in CoC (four of 238 hips [2%]; OR, 0.12 [0.05-0.33]; p < 0.001), but this bearing was frequently revised because of iliopsoas irritation (18 of 238 hips [8%]; OR, 4.9 [2.7-9]; p < 0.001). The time elapsed before revision differed between bearings: median of 3 years (range, 3 days to 28 years) for CoC and 4 years (range, 14 days to 37 years) for MoM versus a median 13 years (range, 0 day to 42 years) for MoP (p < 0.001). Thirty-seven of the 238 revisions (16%) were directly related to ceramic use (ceramic breakage [n = 23], squeaking [n = 6], impingement [n = 7], incorrect ceramic insert insertion [n = 1]). No factors were identified that contributed to breakage of the 12 bulk ceramic components (eight heads, four inserts, four of 12 Delta ceramic). No factors were associated with squeaking, iliopsoas irritation, or impingement, but component orientation was not assessed. CONCLUSIONS: The reasons and time to first revision differed between CoC and other bearings. CoC THAs are revised earlier and are sensitive to mechanical problems such as impingement, squeaking, and ceramic rupture that did not disappear with introduction of Delta ceramics and large-diameter (≥ 36 mm) bearings. CoC was rarely revised for osteolysis, but a high rate of iliopsoas irritation requires further investigation. LEVEL OF EVIDENCE: Level III, therapeutic study.


Asunto(s)
Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/instrumentación , Cerámica , Articulación de la Cadera/cirugía , Prótesis de Cadera , Prótesis Articulares de Metal sobre Metal , Polietileno , Complicaciones Posoperatorias/cirugía , Reoperación , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Fenómenos Biomecánicos , Distribución de Chi-Cuadrado , Femenino , Francia , Articulación de la Cadera/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Oportunidad Relativa , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/etiología , Estudios Prospectivos , Diseño de Prótesis , Factores de Riesgo , Factores de Tiempo , Adulto Joven
11.
Int Orthop ; 40(5): 907-12, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-26572886

RESUMEN

PURPOSE: To assess osseointegration and stability of a primary cementless femoral stem, many scoring systems have been developed, but none of them have taken into account only the radiolucent line. The purposes of this study were (1) to compare the results between the Engh score to assess osseointegration and stability of the cementless stem with results of a score called the O-SS score (osseointegration-secondary stability), which takes into account the radiolucent line, (2) to verify the relationship between these two scores and the functional results, and (3) to verify if there is a relationship between the O-SS score and secondary subsidence or a pedestal. METHODS: A clinical and radiological evaluation was performed in a group of 100 hip prosthesis revisions comparing the results obtained by Engh score and O-SS score for which reproducibility was analysed. RESULTS: Inter-observer reproducibility was estimated to be average at 0.5 and intra-observer reproducibility good at 0.7. The correlation with the Engh score was good at r = 0.59 (p < 0.0001). For the 80 cases assessed O-SS score as very good/good, Harris hip score was at 83.7 versus 78.25 for the 20 cases assessed as average/poor (p = 0.07). For the 73 cases with assessed Engh score as very good/good, this score was at 82.8 versus 82.14 for the 27 cases assessed as average/poor. No correlation between the O-SS score and secondary subsidence (p = 0.2) or pedestal (p = 0.2) was noticed. CONCLUSION: The evaluation of the clear radiolucent line alone, extent and location, is a sufficient condition to assess osseointegration and secondary stability of a cementless femoral stem.


Asunto(s)
Artroplastia de Reemplazo de Cadera/métodos , Articulación de la Cadera/cirugía , Prótesis de Cadera/efectos adversos , Oseointegración , Reoperación/métodos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Articulación de la Cadera/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Diseño de Prótesis , Reproducibilidad de los Resultados , Estudios Retrospectivos
12.
J Sports Sci ; 33(7): 670-4, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25333827

RESUMEN

This study investigated the effects of combined sleep deprivation and strenuous exercise on cognitive and neurobehavioral performance among long-distance runners completing one of the most difficult ultramarathons in the world. Seventeen runners participated. Each had a wrist-worn actigraph throughout the race to record their sleep time. In addition, each individual's performance in 10-min response-time tests before and after the race was recorded and a questionnaire enabled participants to report any difficulties they experienced during the competition. During race completion times of 27 to 44 h, combined acute lack of sleep (12 ± 17 min of rest during the race) and strenuous exercise (168.0 km) had marked adverse effects on cognitive performances ranging from mere lengthening of response time to serious symptoms such as visual hallucinations. This study suggests that regardless of rest duration and time in race, cognitive performances of ultramarathoners are adversely affected.


Asunto(s)
Cognición/fisiología , Resistencia Física/fisiología , Carrera/fisiología , Carrera/psicología , Privación de Sueño/psicología , Actigrafía , Adulto , Conducta Competitiva/fisiología , Alucinaciones/etiología , Humanos , Persona de Mediana Edad , Desempeño Psicomotor/fisiología , Tiempo de Reacción , Encuestas y Cuestionarios
13.
Int Orthop ; 39(8): 1487-94, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25564445

RESUMEN

PURPOSE: The purpose of this study was to finalize a method allowing a qualitative and numerical evaluation of the bone stock and to confirm its reproducibility, to verify the relationship between the secondary bone stock value and the functional results, and to determine the main factors influencing the value of the bone stock. METHODS: A clinical and radiological evaluation was performed in a group of 150 revisions of total hip replacements according to a new method taking into account cortical bone thickness, bone density and bone defects. RESULTS: Interobserver reproducibility was evaluated at an average of 0.6 and intra-observer reproducibility was considered good at 0.8. Between the initial bone stock and at the last follow-up, no significant difference was noticed. For secondary bone stock considered as "very good or good", the gain was +38.1 points versus +29.9 points for patients evaluated as "average or poor" (p < 0.0001). Between the initial bone stock assessment and at last follow-up, a significant relation was found in numerical values for the global type of primary fixation and in the presence of osteopenia (p < 0.0001). CONCLUSIONS: Deficient secondary bone stock can result in less favourable functional results. The numerical scores confirm the importance of strategic choices during surgery in order to manage bone stock preservation.


Asunto(s)
Fémur/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Cadera/métodos , Femenino , Fémur/diagnóstico por imagen , Fémur/patología , Humanos , Masculino , Persona de Mediana Edad , Falla de Prótesis , Radiografía , Reoperación , Reproducibilidad de los Resultados , Estudios Retrospectivos
14.
Res Sports Med ; 23(3): 330-6, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26020095

RESUMEN

We intended to assess the relationship between sleep strategies and performance during the North-Face Ultra-Trail du Mont-Blanc 2013, to test the hypothesis that sleep management can influence athletic performance. Almost all runners specifically adopted sleep management strategies before the race. Among the finishers 72% didn't sleep at all during the race and 28% took a least one break for sleep. Non-sleepers completed the race faster than the sleepers (P = 0.0008). Race time was positively correlated with drowsiness (P < 0.0001) and negatively correlated with the number participations in this race (P = 0.0039). Runners who adopted a sleep management strategy based on increased sleep time before the race completed the race faster (P = 0.0258). Most finishers seemed to be aware of the importance of developing sleep management strategies and increasing sleep time some nights before the race appeared to be the most relevant strategy to improve performance.


Asunto(s)
Rendimiento Atlético/fisiología , Resistencia Física/fisiología , Carrera/fisiología , Sueño/fisiología , Adulto , Conocimientos, Actitudes y Práctica en Salud , Humanos , Persona de Mediana Edad , Fases del Sueño/fisiología , Encuestas y Cuestionarios , Factores de Tiempo
15.
Int Orthop ; 38(5): 923-8, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24323353

RESUMEN

PURPOSE: Cup design has been incriminated as the source of groin pain after hip resurfacing but has not been well described; thus, it was assessed in a prospective study looking at three implant types. METHODS: A group-match was done between three groups of hip resurfacing devices according to age, sex, body mass index, activity level, osteoarthritis aetiology and pre-operative scores. RESULTS: The global groin pain rate was 5.7 % at six months and 2.7 % at last follow-up. Groin pain rate was significantly different between the three groups (p = 0.004) and had a strong influence on the subjective results (p = 0.04). No groin pain emerged between six months and last follow-up. No clinical differences were noted in Harris hip score and Merle d'Aubigné-Postel score at last follow-up. However, the Oxford hip score and Devane activity score were significantly lower for cups with macrostructures. CONCLUSION: The low groin pain rate in this prospective cohort was probably secondary to the specific surgical technique used and seems to be correlated with cup design. Macrostructures on the external part of the cup could be significantly harmful.


Asunto(s)
Prótesis de Cadera/efectos adversos , Dolor/etiología , Femenino , Ingle , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Diseño de Prótesis
16.
Orthop Traumatol Surg Res ; 110(1S): 103779, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38040113

RESUMEN

Current trends in total hip replacement aim at soft tissue and bone stock conservation. At the same time, mean patient age has been decreasing from decade to decade, raising the issue of iterative revision. Short stems seek to resolve the problem on the femoral side. Hopefully, revision of a short stem will be easier and bone stock depletion will be less than with a standard stem. Short stems also seem to have other advantages: automatically personalized biomechanical reconstruction, easier minimally invasive strategies, very low rate of hip pain, more harmonious distribution of bone stress, etc. Despite these advantages, however, use of short stems since their introduction in the late 1980s has varied from country to country, and is not widespread in France. The present study addressed several questions concerning these implants. Firstly, what is a "short" stem? Then, what are the indications and contraindications? Shortened standard stems do not come under the concept of short stem and will not be dealt with here. Furthermore, the learning curve and specificities of short stems need to be acquired. Implantation technique differs greatly from standard stems, and short stem implantation requires particular rigor. Results also need to be assessed, and especially the rate of complications as compared to standard stems. And lastly, it needs to be determined whether the advantages are real or only theoretical: this will determine their usefulness and role in the armamentarium, in which short stems are a new paradigm. LEVEL OF EVIDENCE: Expert opinion.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Humanos , Diseño de Prótesis , Artroplastia de Reemplazo de Cadera/métodos , Fémur , Artralgia , Reoperación
17.
Bone Joint J ; 106-B(3 Supple A): 97-103, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38423079

RESUMEN

Aims: Mechanical impingement of the iliopsoas (IP) tendon accounts for 2% to 6% of persistent postoperative pain after total hip arthroplasty (THA). The most common initiator is anterior acetabular component protrusion, where the anterior margin is not covered by anterior acetabular wall. A CT scan can be used to identify and measure this overhang; however, no threshold exists for determining symptomatic anterior IP impingement due to overhang. A case-control study was conducted in which CT scan measurements were used to define a threshold that differentiates patients with IP impingement from asymptomatic patients after THA. Methods: We analyzed the CT scans of 622 patients (758 THAs) between May 2011 and May 2020. From this population, we identified 136 patients with symptoms suggestive of IP impingement. Among them, six were subsequently excluded: three because the diagnosis was refuted intraoperatively, and three because they had another obvious cause of impingement, leaving 130 hips (130 patients) in the study (impingement) group. They were matched to a control group of 138 asymptomatic hips (138 patients) after THA. The anterior acetabular component overhang was measured on an axial CT slice based on anatomical landmarks (orthogonal to the pelvic axis). Results: The impingement group had a median overhang of 8 mm (interquartile range (IQR) 5 to 11) versus 0 mm (IQR 0 to 4) for the control group (p < 0.001). Using receiver operating characteristic curves, an overhang threshold of 4 mm was best correlated with a diagnosis of impingement (sensitivity 79%, specificity 85%; positive predictive value 75%, negative predictive value 85%). Conclusion: Pain after THA related to IP impingement can be reasonably linked to acetabular overhang if it exceeds 4 mm on a CT scan. Below this threshold, it seems logical to look for another cause of IP irritation or another reason for the pain after THA before concluding that impingement is present.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Humanos , Artroplastia de Reemplazo de Cadera/efectos adversos , Estudios de Casos y Controles , Tendones , Acetábulo/diagnóstico por imagen , Dolor Postoperatorio
18.
Clin Orthop Relat Res ; 471(12): 3863-9, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23529633

RESUMEN

BACKGROUND: There are no large database cohorts describing the causes for failure of primary THAs in France. Because implants and causes for revision vary between national registers, it is important to obtain data from all countries. QUESTIONS/PURPOSES: We therefore determined (1) the mechanisms of failure of primary THAs, (2) their order of appearance with time, (3) the types of surgical techniques and implant designs used to perform revision THAs, and (4) 90-day complications after revision THA in France. METHODS: We prospectively collected data on all 2107 first-time revision THAs from 30 tertiary centers from January 1, 2010, to December 31, 2011. A dual-mobility liner had been used in 251 hips. Mean time from primary procedure to revision THA was 11.2 years (range, 1 day to 42 years). Mean age at revision was 70 years (range, 17-104 years). RESULTS: The causes for revision were mechanical loosening (42%), periprosthetic fracture (12%), infection (11%), wear/osteolysis (11%), dislocation (10%), surgical technique error (6%), and implant fracture (3%). The most common type of revision procedure was all-component revision (49%). A dual-mobility liner was used in 1184 hips (62%). The 90-day dislocation rate was less than 4%, and mortality rate was 1.6%. CONCLUSIONS: Contrary to other reported data, we found dislocation was not the main cause for failure of primary THAs but was still the more frequent early complication after revision. These findings might be related to the use of dual-mobility sockets in more than 10% of primary THAs and more than 60% of revision THAs.


Asunto(s)
Luxación de la Cadera/complicaciones , Articulación de la Cadera/cirugía , Fracturas Periprotésicas/complicaciones , Falla de Prótesis/etiología , Infecciones Relacionadas con Prótesis/complicaciones , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Cadera , Bases de Datos Factuales , Femenino , Francia , Luxación de la Cadera/cirugía , Prótesis de Cadera , Humanos , Masculino , Persona de Mediana Edad , Fracturas Periprotésicas/cirugía , Estudios Prospectivos , Infecciones Relacionadas con Prótesis/cirugía , Reoperación
19.
Clin Orthop Relat Res ; 471(12): 3891-900, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23516032

RESUMEN

BACKGROUND: Dual-mobility (DM) cups were introduced to minimize the risk of THA dislocation. The overall rate of dislocation of DM cups (including both large and small articulations) is controversial and ranges from 0% to 5% in previous studies. QUESTIONS/PURPOSES: We therefore recorded (1) the dislocation rate, (2) loosening and osteolysis, and (3) subsequent related revisions with DM cups. METHODS: Between 1998 and 2003, 2480 primary THAs with DM cups were undertaken in 2179 patients. The mean age was 69 years (range, 19-94 years). This group underwent specific clinical and radiographic evaluation at a minimum followup of 0.17 years (mean, 7 years; range, 0.17-11 years) to assess dislocation, reoperation, osteolysis, and cup fixation. RESULTS: There were 22 dislocations (0.88%): 15 dislocations of large articulations (0.6%), with two (0.08%) recurring but only one requiring revision (0.04%), and seven intraprosthetic small articulation dislocations (0.28%), all needing revision surgery. At last followup, mean Harris hip score was 91 (range, 60-100); 2439 cups (98%) showed no signs of loosening; and 141 patients (145 hips) had osteolysis (6%). Osteolysis and cup loosening were more frequent in patients younger than 50 years at the time of surgery. The 10-year survivorship considering revision for any reason was 93% (95% CI, 91%-95%). CONCLUSIONS: DM cups had a low dislocation rate in primary THA, with a limited frequency of adverse effects. We recommend DM cups to minimize dislocation in populations at high risk for instability, but they should be avoided in younger, active patients at higher risk for osteolysis.


Asunto(s)
Artroplastia de Reemplazo de Cadera/efectos adversos , Luxación de la Cadera/epidemiología , Prótesis de Cadera , Diseño de Prótesis , Falla de Prótesis , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Luxación de la Cadera/etiología , Luxación de la Cadera/cirugía , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Osteólisis/epidemiología , Osteólisis/etiología , Osteólisis/cirugía , Resultado del Tratamiento
20.
Int Orthop ; 37(6): 1019-24, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23456016

RESUMEN

PURPOSE: Although the resumption of low-impact sports activities is compatible with total hip arthroplasty (THA), participation in high-impact sports seems problematic, and there is no consensus as to whether it is advisable. The purpose of this article is to evaluate the quality and possibility of resuming high-impact physical activities after hip resurfacing. MATERIALS: The study was performed in an on-going, single-surgeon, prospective series of 215 resurfacing arthroplasties (RSA). Mean follow-up was 44.1 months (range, 39.1-54.5). Clinical evaluation included the Postel-Merle d'Aubigné (PMA) score, the Oxford hip score, the Harris hip score (HHS), Devane score, and UCLA activity score. A specific questionnaire analysing sports activities was administered to each patient to assess the number and level of physical activities performed (both before the operation and at final follow-up). RESULTS: In the series of 202 consecutive patients (215 RSA), 50 patients (55 RSA) engaged regularly in at least one high-impact activity before their operation and the onset of pain, 102 patients practised at least one intermediate-impact activity, and the 50 remaining patients undertook only low-impact activities. Harris hip score increased from 44.8 (range, 23-68) before the operation to 97.8 (range, 85-100) at the last follow-up. Mean time to sports resumption after surgery was 14.6 weeks (range, 7-29). The resumption rate was 98 % for sports of any impact level and 82 % for high-impact activities. No osteolysis or implant loosening was observed at follow-up. No revision was performed. CONCLUSION: In 2012, no consensus recommendations yet exist for the resumption of sports activities after RSA. Existing recommendations concern only conventional THA. We believe that RSA allows younger and more active patients to resume physical and sports activities without restriction. The rate of return to sports after RSA appears to be excellent and unequalled by conventional hip prostheses. High-impact sports seem to be compatible with hip resurfacing, although no long-term studies have analysed the impact of these activities on wear and/or aseptic loosening.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Articulación de la Cadera/cirugía , Actividad Motora/fisiología , Recuperación de la Función/fisiología , Deportes , Adulto , Artralgia/epidemiología , Femenino , Estudios de Seguimiento , Prótesis de Cadera/efectos adversos , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA