Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Eur Heart J ; 44(46): 4862-4873, 2023 Dec 07.
Artículo en Inglés | MEDLINE | ID: mdl-37930776

RESUMEN

BACKGROUND AND AIMS: For patients with symptomatic, severe tricuspid regurgitation (TR), early results of transcatheter tricuspid valve (TV) intervention studies have shown significant improvements in functional status and quality of life associated with right-heart reverse remodelling. Longer-term follow-up is needed to confirm sustained improvements in these outcomes. METHODS: The prospective, single-arm, multicentre TRISCEND study enrolled 176 patients to evaluate the safety and performance of transcatheter TV replacement in patients with ≥moderate, symptomatic TR despite medical therapy. Major adverse events, reduction in TR grade and haemodynamic outcomes by echocardiography, and clinical, functional, and quality-of-life parameters are reported to one year. RESULTS: Enrolled patients were 71.0% female, mean age 78.7 years, 88.0% ≥ severe TR, and 75.4% New York Heart Association classes III-IV. Tricuspid regurgitation was reduced to ≤mild in 97.6% (P < .001), with increases in stroke volume (10.5 ± 16.8 mL, P < .001) and cardiac output (0.6 ± 1.2 L/min, P < .001). New York Heart Association class I or II was achieved in 93.3% (P < .001), Kansas City Cardiomyopathy Questionnaire score increased by 25.7 points (P < .001), and six-minute walk distance increased by 56.2 m (P < .001). All-cause mortality was 9.1%, and 10.2% of patients were hospitalized for heart failure. CONCLUSIONS: In an elderly, highly comorbid population with ≥moderate TR, patients receiving transfemoral EVOQUE transcatheter TV replacement had sustained TR reduction, significant increases in stroke volume and cardiac output, and high survival and low hospitalization rates with improved clinical, functional, and quality-of-life outcomes to one year. Funded by Edwards Lifesciences, TRISCEND ClinicalTrials.gov number, NCT04221490.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Humanos , Femenino , Anciano , Masculino , Insuficiencia de la Válvula Tricúspide/epidemiología , Insuficiencia de la Válvula Tricúspide/cirugía , Válvula Tricúspide/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Estudios Prospectivos , Calidad de Vida , Resultado del Tratamiento , Cateterismo Cardíaco/métodos , Índice de Severidad de la Enfermedad
2.
J Cardiovasc Electrophysiol ; 34(11): 2225-2232, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37702135

RESUMEN

INTRODUCTION: The need for pacemaker is a common complication after transcatheter aortic valve replacement (TAVR). We previously described the Emory Risk Score (ERS) to predict the need for new pacemaker implant (PPM) after TAVR. Metrics included in the score are a history of syncope, pre-existing RBBB, QRS duration ≥140 ms, and prosthesis oversizing ≥16%. To prospectively validate the previously described risk score. METHODS: We prospectively evaluated all patients without pre-existing pacemakers, ICD, or pre-existing indications for pacing undergoing TAVR with the Edwards SAPIEN 3 prosthesis at our institution from March 2019 to December 2020 (n = 661). Patients were scored prospectively; however, results were blinded from clinical decision-making. The primary endpoint was PPM at 30 days after TAVR. Performance of the ERS was evaluated using logistic regression, a calibration curve to prior performance, and receiver operating characteristic (ROC) analysis. RESULTS: A total of 48 patients (7.3%) had PPM after TAVR. A higher ERS predicted an increased likelihood of PPM (OR 2.61, 95% CI: 2.05-3.25 per point, p < 0.001). There was good correlation between observed and expected values on the calibration curve (slope = 1.04, calibration at large = 0.001). The area under the ROC curve was 0.81 (95% CI [0.74-0.88], p < 0.001). CONCLUSIONS: The ERS prospectively predicted the need for PPM in a serial, real-world cohort of patients undergoing TAVR with a balloon-expandable prosthesis, confirming findings previously described in retrospective cohorts. Notably, the prospective performance of the score was comparable with that of the initial cohorts. The risk score could serve as a framework for preprocedural risk stratification for PPM after TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estudios Retrospectivos , Estimulación Cardíaca Artificial/efectos adversos , Estimulación Cardíaca Artificial/métodos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Factores de Riesgo , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía
3.
Catheter Cardiovasc Interv ; 97(5): 940-947, 2021 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-33382519

RESUMEN

OBJECTIVES: We sought to evaluate the safety, efficacy and feasibility of same-day discharge after uncomplicated, minimalist TAVR. BACKGROUND: At the start of the COVID-19 pandemic, we created a same-day discharge (SDD) pathway after conscious sedation, transfemoral (minimalist) TAVR to help minimize risk of viral transmission and conserve hospital resources. Studies support that next-day discharge (NDD) for carefully selected patients following minimalist TAVR is safe and feasible. There is a paucity of data regarding the safety of SDD after TAVR. METHODS: In-hospital and 30 day outcomes of consecutive patients meeting pre-specified criteria for SDD after minimalist TAVR at our institution between March and July of 2020 were reviewed. Outcomes were compared to a NDD cohort from July 2018 through July 2020 that would have met SDD criteria. Primary endpoints were mortality, delayed pacemaker placement, stroke and cardiovascular readmission at 30 days. RESULTS: Twenty nine patients were discharged via the SDD pathway after TAVR. 128 prior NDD patients were identified who met all criteria for SDD. The STS scores were similar between the two groups (SDD 2.6% ±1.5 vs. NDD 2.3% ± 1.2). There were no deaths at 30 days in either group. There was no significant difference in delayed pacemaker placement (SDD 0% vs. NDD 0.8%, p > .99) or cardiovascular readmission (SDD 0% vs. NDD 5.5%, p = .35) at 30 days. CONCLUSIONS: Same day discharge following uncomplicated, minimalist TAVR in selected patients appears to be safe, achieving similar 30 day outcomes as a cohort of next day discharge patients.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , COVID-19/epidemiología , Pandemias , Alta del Paciente/tendencias , Medición de Riesgo/métodos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/epidemiología , Comorbilidad , Femenino , Estudios de Seguimiento , Humanos , Tiempo de Internación/tendencias , Masculino , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo
4.
Catheter Cardiovasc Interv ; 97(3): 529-539, 2021 02 15.
Artículo en Inglés | MEDLINE | ID: mdl-32845036

RESUMEN

BACKGROUND: There is a paucity of data regarding the optimum timing of PCI in relation to TAVR. OBJECTIVE: We compared the major adverse cardiovascular and cerebrovascular events (MACCE) rates among patients who underwent percutaneous coronary intervention (PCI) before transcatheter aortic valve replacement (TAVR) with those who received PCI with/after TAVR. METHODS: In this multicenter study, we pooled all consecutive patients who underwent TAVR at three high volume centers. RESULTS: Among 3,982 patients who underwent TAVR, 327 (8%) patients underwent PCI within 1 year before TAVR, 38 (1%) had PCI the same day as TAVR and 15 (0.5%) had PCI within 2 months after TAVR. Overall, among patients who received both PCI and TAVR (n = 380), history of previous CABG (HR:0.501; p = .001), higher BMI at TAVR (HR:0.970; p = .038), and statin therapy after TAVR (HR:0.660, p = .037) were independently associated with lower MACCE while warfarin therapy after TAVR was associated with a higher risk of MACCE (HR:1.779, p = .017). Patients who received PCI within 1 year before TAVR had similar baseline demographics, STS scores, clinical risk factors when compared to patients receiving PCI with/after TAVR. Both groups were similar in PCI (Syntax Score, ACC/AHA lesion class) and TAVR (valve types, access) related variables. There were no significant differences in terms of MACCE (log rank p = .550), all-cause mortality (log rank p = .433), strokes (log rank p = .153), and repeat PCI (log rank p = .054) in patients who underwent PCI with/after TAVR when compared to patients who received PCI before TAVR. CONCLUSION: Among patients who underwent both PCI and TAVR, history of CABG, higher BMI, and statin therapy had lower, while those discharged on warfarin, had higher adverse event rates. Adverse events rates were similar regardless of timing of PCI.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Arteria Coronaria , Intervención Coronaria Percutánea , Reemplazo de la Válvula Aórtica Transcatéter , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Enfermedad de la Arteria Coronaria/cirugía , Enfermedad de la Arteria Coronaria/terapia , Humanos , Intervención Coronaria Percutánea/efectos adversos , Sistema de Registros , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
5.
JACC Cardiovasc Interv ; 17(5): 635-644, 2024 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-38244000

RESUMEN

BACKGROUND: Transcatheter closure of transcatheter heart valve (THV)-related paravalvular leak (PVL) is associated with a high failure rate with available devices due to the complex interaction of THV and aortic/mitral annulus. OBJECTIVES: This study reports on novel transcatheter techniques to treat PVL after THV. METHODS: The authors describe consecutive patients who underwent PVL closure after transcatheter aortic valve replacement (TAVR) or transcatheter mitral valve replacement (TMVR). A covered self-expanding stent (Viabahn) was deployed in the defect to create a seal between the THV and annulus. A vascular plug (Amplatzer Vascular Plug 2 [AVP2] or AVP4) was then deployed inside the covered stent to obliterate PVL. RESULTS: Eight patients with THV-related PVL were treated using this method (aortic [3 SAPIEN, 1 Evolut], mitral [2 SAPIEN-in-MAC (mitral annular calcification), 2 M3 TMVR). Various combinations of stents and plugs were used (5 mm × 2.5 cm Viabahn + 6 mm AVP4 [n = 2], 8 mm × 2.5 cm Viabahn + 10 mm AVP2 [n = 5], and 10 mm × 5.0 cm Viabahn + 12 mm AVP2 [n = 1]). All had technical success with immediate elimination of target PVL, without in-hospital complications. None had signs of postprocedure hemolysis. All patients were discharged alive (median 3.5 days [Q1-Q3: 1.0-4.8 days]). No residual PVL was seen at discharge, except for 1 patient with mild regurgitation due to another untreated PVL location. One patient died before 30 days due to complication of valve-in-MAC TMVR. In remaining patients, none had recurrence of PVL at 30 days. Symptoms decreased to NYHA functional class I/II in 6 patients. NYHA functional class III symptoms remained in 1 patient with mitral regurgitation awaiting subsequent valve replacement procedure. CONCLUSIONS: The technique of sequential deployment of a covered stent and vascular plug may effectively treat THV-related PVL.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Prótesis Valvulares Cardíacas/efectos adversos , Falla de Prótesis , Resultado del Tratamiento , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Stents , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía
6.
Am J Cardiol ; 220: 84-91, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38604492

RESUMEN

Development of functional tricuspid regurgitation (TR) because of chronic mitral disease and subsequent heart failure is common. However, the effect of TR on clinical outcomes after transcatheter mitral valve replacement (TMVR) remains unclear. We aimed to evaluate the impact of baseline TR on outcomes after TMVR. This was a single-center, retrospective analysis of patients who received valve-in-valve or valve-in-ring TMVR between 2012 and 2022. Patients were categorized into none/mild TR and moderate/severe TR based on baseline echocardiography. The primary outcome was 3 years all-cause death and the secondary outcomes were in-hospital events. Of the 135 patients who underwent TMVR, 64 (47%) exhibited none/mild TR at baseline, whereas 71 (53%) demonstrated moderate/severe TR. There were no significant differences in in-hospital events between the groups. At 3 years, the moderate/severe TR group exhibited a significantly increased risk of all-cause death (adjusted hazard ratio 3.37, 95% confidence interval 1.35 to 8.41, p = 0.009). When patients with baseline moderate/severe TR were stratified by echocardiography at 30 days into improved (36%) and nonimproved (64%) TR groups, although limited by small sample size, there was no significant difference in 3-year all-cause mortality (p = 0.48). In conclusion, this study investigating the impact of baseline TR on clinical outcomes revealed that moderate/severe TR is prevalent in those who underwent TMVR and is an independent predictor of 3-year all-cause mortality. Earlier mitral valve intervention before the development of significant TR may play a pivotal role in improving outcomes after TMVR.


Asunto(s)
Ecocardiografía , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Insuficiencia de la Válvula Tricúspide , Humanos , Masculino , Insuficiencia de la Válvula Tricúspide/cirugía , Femenino , Estudios Retrospectivos , Anciano , Implantación de Prótesis de Válvulas Cardíacas/métodos , Insuficiencia de la Válvula Mitral/cirugía , Cateterismo Cardíaco/métodos , Índice de Severidad de la Enfermedad , Resultado del Tratamiento , Causas de Muerte/tendencias , Complicaciones Posoperatorias/epidemiología , Anciano de 80 o más Años , Válvula Mitral/cirugía , Válvula Mitral/diagnóstico por imagen
7.
J Am Coll Cardiol ; 83(14): 1257-1272, 2024 Apr 09.
Artículo en Inglés | MEDLINE | ID: mdl-38471643

RESUMEN

BACKGROUND: Left ventricular outflow tract (LVOT) obstruction is a source of morbidity in hypertrophic cardiomyopathy (HCM) and a life-threatening complication of transcatheter mitral valve replacement (TMVR) and transcatheter aortic valve replacement (TAVR). Available surgical and transcatheter approaches are limited by high surgical risk, unsuitable septal perforators, and heart block requiring permanent pacemakers. OBJECTIVES: The authors report the initial experience of a novel transcatheter electrosurgical procedure developed to mimic surgical myotomy. METHODS: We used septal scoring along midline endocardium (SESAME) to treat patients, on a compassionate basis, with symptomatic LVOT obstruction or to create space to facilitate TMVR or TAVR. RESULTS: In this single-center retrospective study between 2021 and 2023, 76 patients underwent SESAME. In total, 11 (14%) had classic HCM, and the remainder underwent SESAME to facilitate TMVR or TAVR. All had technically successful SESAME myocardial laceration. Measures to predict post-TMVR LVOT significantly improved (neo-LVOT 42 mm2 [Q1-Q3: 7-117 mm2] to 170 mm2 [Q1-Q3: 95-265 mm2]; P < 0.001; skirt-neo-LVOT 169 mm2 [Q1-Q3: 153-193 mm2] to 214 mm2 [Q1-Q3: 180-262 mm2]; P < 0.001). Among patients with HCM, SESAME significantly decreased invasive LVOT gradients (resting: 54 mm Hg [Q1-Q3: 40-70 mm Hg] to 29 mm Hg [Q1-Q3: 12-36 mm Hg]; P = 0.023; provoked 146 mm Hg [Q1-Q3: 100-180 mm Hg] to 85 mm Hg [Q1-Q3: 40-120 mm Hg]; P = 0.076). A total of 74 (97.4%) survived the procedure. Five experienced 3 of 76 (3.9%) iatrogenic ventricular septal defects that did not require repair and 3 of 76 (3.9%) ventricular free wall perforations. Neither occurred in patients treated for HCM. Permanent pacemakers were required in 4 of 76 (5.3%), including 2 after concomitant TAVR. Lacerations were stable and did not propagate after SESAME (remaining septum: 5.9 ± 3.3 mm to 6.1 ± 3.2 mm; P = 0.8). CONCLUSIONS: With further experience, SESAME may benefit patients requiring septal reduction therapy for obstructive hypertrophic cardiomyopathy as well as those with LVOT obstruction after heart valve replacement, and/or can help facilitate transcatheter valve implantation.


Asunto(s)
Cardiomiopatía Hipertrófica , Implantación de Prótesis de Válvulas Cardíacas , Miotomía , Obstrucción del Flujo de Salida Ventricular Izquierda , Obstrucción del Flujo Ventricular Externo , Humanos , Válvula Mitral/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Estudios Retrospectivos , Cateterismo Cardíaco/métodos , Obstrucción del Flujo Ventricular Externo/etiología , Obstrucción del Flujo Ventricular Externo/cirugía , Resultado del Tratamiento , Cardiomiopatía Hipertrófica/complicaciones , Miotomía/efectos adversos
8.
Methodist Debakey Cardiovasc J ; 19(3): 37-49, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37213881

RESUMEN

Transcatheter mitral valve replacement (TMVR) using the SAPIEN platform has been performed in failed bioprosthetic valves (valve-in-valve), surgical annuloplasty rings (valve-in-ring), and native valves with mitral annular calcification (MAC) (valve-in-MAC). Experience over the past decade has identified important challenges and solutions to improve clinical outcomes. In this review, we discuss the indication, trend in utilization, unique challenges, procedural planning, and clinical outcomes of valve-in-valve, valve-in-ring, and valve-in-MAC TMVR.


Asunto(s)
Calcinosis , Enfermedades de las Válvulas Cardíacas , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Resultado del Tratamiento , Cateterismo Cardíaco/efectos adversos , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/cirugía , Calcinosis/diagnóstico por imagen , Calcinosis/etiología , Calcinosis/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/etiología , Insuficiencia de la Válvula Mitral/cirugía
9.
Cardiovasc Revasc Med ; 53S: S176-S179, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-35879191

RESUMEN

A cardiogenic shock patient with a history of a surgical mitral valve replacement presented to the hospital with critical mitral stenosis with thickening of prosthetic valve leaflets and thrombus in left atrial appendage. We considered TMVR inside of the degenerated bioprosthetic valve. However, there were two concerns during TMVR based on multimodality imaging assessment: 1) LVOT obstruction due to the surgical bioprosthetic leaflet, 2) stroke due to left atrial appendage thrombus. We performed TMVR with LAMPOON (laceration of the anterior leaflet of the surgical valve to prevent left ventricular outflow tract obstruction) for the bioprosthesis using cerebral protection. While the LAMPOON procedure has developed to prevent LVOT obstruction by the native anterior mitral leaflet during transcatheter mitral valve-in-ring or valve-in-mitral annular calcification, this is the first case that illustrates its use for mitral valve-in-valve replacement.


Asunto(s)
Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Trombosis , Obstrucción del Flujo Ventricular Externo , Humanos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Factores de Riesgo , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/métodos , Resultado del Tratamiento
10.
Circ Cardiovasc Interv ; 16(9): e013123, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37577788

RESUMEN

BACKGROUND: Transcatheter pulmonary valve replacement (TPVR) in patients with a congenital or acquired abnormality resulting in enlarged right ventricular outflow tract (RVOT) is challenging and may preclude treatment with dedicated devices. We describe a technique using a physician-modified endograft to facilitate TPVR. METHODS: Six patients underwent physician-modified endograft-facilitated TPVR for severe symptomatic pulmonary insufficiency with enlarged RVOT. The fenestration was created in a commercially available endograft before implantation, which was then deployed from the dominant branch pulmonary artery into the RVOT, with the fenestration aligned with the ostium of the nondominant pulmonary artery. A covered stent was placed through the fenestration into the nondominant branch pulmonary artery, and a transcatheter heart valve was deployed within the endograft at the level of the original pulmonary valve. RESULTS: Four patients had tetralogy of Fallot, 1 had pulmonary atresia, and 1 had rheumatic valve disease. The RVOT/main pulmonary artery was severely enlarged (diameter, 44.2 [43.5-50.6] mm). All patients had reduced right ventricular (RV) function and dilated RVs (RV end-diastolic volume, 314 [235-316] mL). Successful endograft, covered stent, and transcatheter heart valve deployment were achieved in all cases without stent/valve embolization, vascular complications, or bleeding complications. At 30 days, 1 patient had mild pulmonary insufficiency, while others had none. The RV size measured by echocardiography was significantly reduced after TPVR (RV area, 34.4 [baseline] versus 29.0 [pre-discharge] versus 25.3 [30 days] cm2; P=0.03). During median follow-up of 221.5 (range, 29-652) days, there were no deaths or need for pulmonary valve reintervention. One patient developed severe tricuspid regurgitation due to entrapment of the anterior tricuspid leaflet by the endograft. The patient underwent successful tricuspid replacement and resection of the offending endograft with preservation of the pulmonary valve prosthesis. CONCLUSIONS: Simple fenestration of an off-the-shelf endograft and associated covered stent placement through the fenestration allows TPVR for patients with dysfunctional native or patch-repaired pulmonary valves and RVOT enlargement.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Pulmonar , Válvula Pulmonar , Humanos , Válvula Pulmonar/diagnóstico por imagen , Válvula Pulmonar/cirugía , Cateterismo Cardíaco , Resultado del Tratamiento , Prótesis Valvulares Cardíacas/efectos adversos , Insuficiencia de la Válvula Pulmonar/diagnóstico por imagen , Insuficiencia de la Válvula Pulmonar/etiología , Insuficiencia de la Válvula Pulmonar/cirugía , Stents/efectos adversos , Estudios Retrospectivos , Diseño de Prótesis
11.
Circ Cardiovasc Interv ; 16(10): e013243, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37732604

RESUMEN

BACKGROUND: Postinfarction ventricular septal defect (VSD) is a catastrophic complication of myocardial infarction. Surgical repair still has poor outcomes. This report describes clinical outcomes after a novel hybrid transcatheter/surgical repair in patients with apical VSD. METHODS: Seven patients with postmyocardial infarction apical VSD underwent hybrid transcatheter repair via subxiphoid surgical access. A transcatheter occluder (Amplatzer Septal Occluder) with a trailing premounted suture was deployed through the right ventricular wall and through the ventricular septum into the left ventricular apex. The trailing suture was used to connect an anchor external to the right ventricular wall. Tension on the suture then collapses the right ventricular free wall against the septum and left ventricular occluder, thereby obliterating the VSD. Outcomes were compared with 9 patients who underwent surgical repair using either patch or primary suture closure. RESULTS: All patients had significant left-to-right shunt (Qp:Qs 2.5:1; interquartile range [IQR, 2.1-2.6] hybrid repair versus 2.0:1 [IQR, 2.0-2.5] surgical repair), and elevated right ventricular systolic pressure (62 [IQR, 46-71] versus 49 [IQR, 43-54] mm Hg, respectively). All had severely depressed stroke volume index (22 versus 21 mL/m2) with ≈45% in each group requiring mechanical support preprocedurally. The procedure was done 15 (IQR, 10-50) versus 24 (IQR, 10-134) days postmyocardial infarction, respectively. Both groups of patients underwent repair with technical success and without intraprocedural death. One patient in the hybrid group and 4 in the surgical group developed multiorgan failure. The hybrid group had a higher survival at discharge (86% versus 56%) and at 30 days (71% versus 56%), but similar at 1 year (57% versus 56%). During follow-up, 1 patient in each group required reintervention for residual VSD (hybrid: 9 months versus surgical: 5 days). CONCLUSIONS: Early intervention with a hybrid transcatheter/surgical repair may be a viable alternative to traditional surgery for postinfarction apical VSD.


Asunto(s)
Infarto de la Pared Anterior del Miocardio , Defectos del Tabique Interventricular , Infarto del Miocardio , Dispositivo Oclusor Septal , Humanos , Resultado del Tratamiento , Cateterismo Cardíaco , Defectos del Tabique Interventricular/diagnóstico por imagen , Defectos del Tabique Interventricular/etiología , Defectos del Tabique Interventricular/cirugía , Infarto del Miocardio/complicaciones , Infarto del Miocardio/diagnóstico por imagen , Infarto del Miocardio/terapia
12.
Interv Cardiol Clin ; 11(1): 11-25, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34838294

RESUMEN

Transcatheter tricuspid valve (TV) interventions have increased dramatically in recent years. TV imaging is challenging in many respects. Given the TV's anatomic complexity, multimodality imaging, which is centered on echocardiography (echo), plays a significant part in planning and execution of these interventions. With the help of echo-guided imaging, pathophysiologic mechanisms for TV disease are better understood, and thus, appropriate valve intervention can be strategized. Novel devices for the TV continue to be developed, and thus, intraprocedural echo imaging will continue to evolve in the days ahead.


Asunto(s)
Enfermedades de las Válvulas Cardíacas , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Ecocardiografía , Humanos , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/cirugía
13.
JACC Cardiovasc Interv ; 15(12): 1249-1263, 2022 06 27.
Artículo en Inglés | MEDLINE | ID: mdl-35738745

RESUMEN

BACKGROUND: Transcatheter mitral valve repair is beneficial in patients with mitral regurgitation (MR), left ventricular dysfunction, and persistent symptoms despite maximally tolerated medical therapy. OBJECTIVES: The aim of this study was to evaluate the safety and feasibility of transcatheter mitral cerclage ventriculoplasty in patients with MR and either heart failure with reduced ejection fraction or preserved ejection fraction and in subjects with prior edge-to-edge repair but persistent or recurrent symptomatic MR. METHODS: The National Heart, Lung, and Blood Institute Division of Intramural Research Transcatheter Mitral Cerclage Ventriculoplasty Early Feasibility Study (NCT03929913) was an investigator-initiated prospective multicenter study. The primary endpoint was technical success measured at exit from the catheterization laboratory. Follow-up included heart failure quality-of-life assessments and serial imaging with echocardiography and cardiac computed tomography. RESULTS: Nineteen subjects consented and underwent cerclage, 63% with heart failure with reduced ejection fraction and 37% with heart failure with preserved ejection fraction, with ischemic cardiomyopathy in 26% and nonischemic cardiomyopathy in 74%. There were no procedural deaths, strokes, or transient ischemic attacks or other major cardiovascular adverse events. The primary endpoint was met in 17 subjects. Cerclage induced sustained reductions in mitral regurgitant volume (-41%) and effective orifice area (-33%) after a median of 337 days. Cerclage resulted in improvements in 6-minute walking distance (+78 m) and Kansas City Cardiomyopathy Questionnaire Overall Summary Score (+22 points) at 30 days that were maintained after a median of 265 days. New complete heart block developed in 6 of 17 subjects. Three deaths occurred on postprocedural days 79, 159, and 756, unrelated to cerclage. CONCLUSIONS: Transcatheter mitral cerclage ventriculoplasty resulted in significant and sustained improvements in mitral regurgitation and in heart failure quality-of-life assessments.


Asunto(s)
Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Disfunción Ventricular Izquierda , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/métodos , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/terapia , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/etiología , Insuficiencia de la Válvula Mitral/cirugía , Estudios Prospectivos , Resultado del Tratamiento
14.
Ann Cardiothorac Surg ; 10(5): 605-620, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34733688

RESUMEN

Valve-in-valve (ViV) transcatheter procedures are the preferred option for redo valve replacement in patients who otherwise would be high risk for surgery. Transesophageal echocardiography (TEE) is an integral imaging modality for both peri-procedural and intra-procedural guidance during transcatheter ViV replacement. When intentional leaflet laceration is needed, such as with the BASILICA (Bioprosthetic or native Aortic Scallop Intentional Laceration to prevent Iatrogenic Coronary Artery obstructions during TAVR) or LAMPOON (Laceration of the Anterior Mitral valve leaflet to Prevent left ventricular Outlet ObstructioN) procedures, TEE is critical to proper guidewire positioning and achieving a successful laceration. In this paper we detail the role of TEE in ViV transcatheter valve replacement in patients with prior surgical aortic, mitral, tricuspid, and pulmonic valves.

15.
Circ Cardiovasc Interv ; 14(11): e011028, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34674556

RESUMEN

BACKGROUND: Bioprosthetic or native aortic scallop intentional laceration to prevent iatrogenic coronary artery obstruction (BASILICA) and laceration of the anterior mitral leaflet to prevent outflow obstruction (LAMPOON) reduce the risk of coronary and left ventricular outflow obstruction obstruction during transcatheter aortic valve replacement and transcatheter mitral valve replacement. Despite successful laceration, BASILICA or LAMPOON may fail to prevent obstruction caused by inadequate leaflet splay in patients having challenging anatomy such as very small valve-to-coronary distance, diffusely calcified, rigid leaflets, or undergoing transcatheter aortic valve replacement inside existing transcatheter aortic valve replacement. We describe a novel technique of balloon-augmented (BA) leaflet laceration to enhance leaflet splay. METHODS: We measured the incremental leaflet splay from BA-BASILICA in vitro. From November 2019 to March 2021, 16 patients underwent BA-BASILICA and 4 BA-LAMPOON at 3 centers. RESULTS: BA-BASILICA increased benchtop leaflet tip splay 17%, maximum splay angle 30%, and splay area 23%, resulting in a more rounded apex and larger effective area. Sixteen patients at risk for inadequate BASILICA leaflet splay, including 4 transcatheter aortic valve replacement inside existing transcatheter aortic valve replacement, underwent BA-BASILICA. All had successful leaflet laceration. One had coronary obstruction requiring immediate orthotopic stenting. Two underwent elective orthotopic coronary stenting through the transcatheter valve cells for leaflet prolapse without coronary ischemia. There were no deaths during the procedure or at 30 days. Four patients at risk for inadequate anterior mitral leaflet splay underwent BA-LAMPOON. All had successful target leaflet laceration without left ventricular outflow obstruction obstruction or procedural death. One died within 30 days. CONCLUSIONS: BA leaflet laceration enhances leaflet splay in vitro and may allow transcatheter aortic valve replacement and transcatheter mitral valve replacement in patients otherwise ineligible for traditional BASILICA or LAMPOON due to challenging anatomy. Graphic Abstract: A graphic abstract is available for this article.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Laceraciones , Pectinidae , Reemplazo de la Válvula Aórtica Transcatéter , Animales , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Enfermedad Iatrogénica/prevención & control , Laceraciones/etiología , Laceraciones/prevención & control , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
16.
JACC Cardiovasc Interv ; 14(20): 2195-2214, 2021 10 25.
Artículo en Inglés | MEDLINE | ID: mdl-34674861

RESUMEN

The SAPIEN 3 is the only transcatheter heart valve commercially available for compassionate transcatheter mitral valve replacement in patients with previous mitral surgical rings and mitral annular calcification (valve in ring [VIR] and valve in mitral annular calcification [VIM]). Reported outcomes have been inconsistent or poor. The review provides an overview of the authors' approach to achieve largely consistent results despite the intrinsic limitations of SAPIEN 3 VIM and VIR. The approach includes bedside modifications of the valve implant, the delivery system, and of the cardiac substrate itself. Until purpose-built devices are readily available, VIR and VIM procedures will require aggressive multidisciplinary cooperation, meticulous planning and execution, and postprocedure management by experienced, high-volume operators.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Cateterismo Cardíaco/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Resultado del Tratamiento
17.
JACC Cardiovasc Interv ; 14(5): 541-550, 2021 03 08.
Artículo en Inglés | MEDLINE | ID: mdl-33663781

RESUMEN

OBJECTIVES: The purpose of this study was to evaluate tip-to-base intentional laceration of the anterior mitral leaflet to prevent left ventricular outflow tract obstruction (LAMPOON) in patients undergoing transcatheter mitral valve replacement (TMVR) in annuloplasty rings or surgical mitral valves. BACKGROUND: LAMPOON is an effective adjunct to TMVR that prevents left ventricular outflow tract obstruction (LVOTO). Laceration is typically performed from the base to the tip of the anterior mitral leaflet. A modified laceration technique from leaflet tip to base may be effective in patients with a prosthesis that protects the aortomitral curtain. METHODS: This is a multicenter, 21-patient, consecutive retrospective observational cohort. Patients underwent tip-to-base LAMPOON to prevent LVOTO and leaflet overhang, or therapeutically to lacerate a long anterior mitral leaflet risking or causing LVOTO. Outcomes were compared with findings from patients in the LAMPOON investigational device exemption trial with a prior mitral annuloplasty. RESULTS: Twenty-one patients with a annuloplasty or valve prosthesis-protected mitral annulus underwent tip-to-base LAMPOON (19 preventive, 2 rescue). Leaflet laceration was successful in all and successfully prevented or treated LVOTO in all patients. No patients had significant LVOTO upon discharge. There were 2 cases of unintentional aortic valve injury (1 patient underwent emergency transcatheter aortic valve replacement and 1 patient underwent urgent surgical aortic valve replacement). In both cases, the patients had a supra-annular ring annuloplasty, and the retrograde aortic guiding catheter failed to insulate the guidewire lacerating surface from the aortic root. All patients survived to 30 days. Compared with classic retrograde LAMPOON, there was a trend toward shorter procedure time. CONCLUSIONS: Tip-to-base laceration is a simple, effective, and safe LAMPOON variant applicable to patients with an appropriately positioned mitral annular ring or bioprosthetic valve. Operators should take care to insulate the lacerating surface from adjacent structures.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral , Obstrucción del Flujo Ventricular Externo , Cateterismo Cardíaco/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Estudios Retrospectivos , Resultado del Tratamiento
18.
JACC Cardiovasc Interv ; 13(23): 2755-2765, 2020 12 14.
Artículo en Inglés | MEDLINE | ID: mdl-33303113

RESUMEN

OBJECTIVES: The aim of this study was to test the hypothesis that narrowing the landing zone using commercially available endografts would enable transcatheter pulmonary valve replacement (TPVR) using commercially available transcatheter heart valves. BACKGROUND: TPVR is challenging in an outsized native or patch-repaired right ventricular outflow tract (RVOT). Downsizing the RVOT for TPVR is currently possible only using investigational devices. In patients ineligible because of excessive RVOT size, TPVR landing zones were created using commercially available endografts. METHODS: Consecutive patients with native or patch-repaired RVOTs and high or prohibitive surgical risk were reviewed, and this report describes the authors' experience with endograft-facilitated TPVR (EF-TPVR) offered to patients ineligible for investigational or commercial devices. All EF-TPVR patients were surgery ineligible, with symptomatic, severe pulmonary insufficiency, enlarged RVOTs, and severe right ventricular (RV) enlargement (>150 ml/m2). TPVR and surgical pulmonary valve replacement (SPVR) were compared in patients with less severe RV enlargement. RESULTS: Fourteen patients had large RVOTs unsuitable for conventional TPVR; 6 patients (1 surgery ineligible) received investigational devices, and 8 otherwise ineligible patients underwent compassionate EF-TPVR (n = 5 with tetralogy of Fallot). Three strategies were applied on the basis of progressively larger RVOT size: single-barrel, in situ fenestrated, and double-barrel endografts as required to anchor 1 (single-barrel and fenestrated) or 2 (double-barrel) transcatheter heart valves. All were technically successful, without procedure-related, 30-day, or in-hospital deaths. Two late complications (stent obstruction and embolization) were treated percutaneously. One patient died of ventricular tachycardia 36 days after EF-TPVR. Compared with 48 SPVRs, RV enlargement was greater, but 30-day and 1-year mortality and readmission were no different. The mean transvalvular pressure gradient was lower after EF-TPVR (3.8 ± 0.8 mm Hg vs. 10.7 ± 4.1 mm Hg; p < 0.001; 30 days). More than mild pulmonary insufficiency was equivalent in both (EF-TPVR 0.0% [n = 0 of 8] vs. SPVR 4.3% [n = 1 of 43]; p = 1.00; 30 days). CONCLUSIONS: EF-TPVR may be an alternative for patients with pulmonic insufficiency and enlarged RVOTs ineligible for other therapies.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Pulmonar , Válvula Pulmonar , Adulto , Cateterismo Cardíaco , Femenino , Humanos , Masculino , Válvula Pulmonar/cirugía , Insuficiencia de la Válvula Pulmonar/cirugía , Estudios Retrospectivos , Stents , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda , Función Ventricular Derecha , Adulto Joven
19.
Circ Cardiovasc Interv ; 13(6): e008903, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32513014

RESUMEN

BACKGROUND: Intentional laceration of the anterior mitral leaflet (LAMPOON) is an effective adjunct to transcatheter mitral valve replacement that prevents left ventricular outflow tract (LVOT) obstruction. To date, LAMPOON has been performed in over 150 patients using a retrograde approach that can be technically challenging. A modified antegrade transseptal technique may simplify the procedure. METHODS: Antegrade LAMPOON was developed and tested in nonsurvival pig experiments. Thereafter, antegrade LAMPOON was performed in patients at prohibitive risk of LVOT obstruction. Clinical, procedural, and angiographic details were abstracted from medical records of their index procedure, and were compared with findings in comparable patients at risk of fixed-LVOT obstruction in the LAMPOON investigational device exemption trial. RESULTS: Eight patients at risk of fixed LVOT obstruction underwent antegrade LAMPOON. Leaflet traversal and laceration were technically successful in all. There were no cases of clinically significant LVOT obstruction (mean LVOT gradient at discharge: 5.4±1.4 mm Hg). One patient suffered a ventricular wire perforation, unrelated to the antegrade LAMPOON technique, and did not survive to discharge. At the time of discharge, no patients had an increase of >10 mm Hg in LVOT gradient compared with baseline. Procedure times (from traversal to transcatheter mitral valve replacement) were shorter, compared with the retrograde technique in the LAMPOON investigational device exemption trial (39±09 versus 65±35 minutes). All patients survived (8/8, 100%) the procedure, and 7/8 (88%) survived to 30 days, similar to subjects in the LAMPOON investigational device exemption trial. CONCLUSIONS: Antegrade LAMPOON is an effective, reproducible, and simplified strategy to lacerate the anterior leaflet before transcatheter mitral valve replacement. The authors recommend the technique as the new standard for LAMPOON.


Asunto(s)
Cateterismo Cardíaco , Procedimientos Quirúrgicos Cardíacos , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral/cirugía , Estenosis de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Obstrucción del Flujo Ventricular Externo/prevención & control , Animales , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Femenino , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Humanos , Masculino , Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/fisiopatología , Estenosis de la Válvula Mitral/fisiopatología , Modelos Animales , Tempo Operativo , Estudios Retrospectivos , Factores de Riesgo , Sus scrofa , Investigación Biomédica Traslacional , Resultado del Tratamiento , Obstrucción del Flujo Ventricular Externo/etiología , Obstrucción del Flujo Ventricular Externo/fisiopatología
20.
JACC Cardiovasc Interv ; 13(20): 2361-2370, 2020 10 26.
Artículo en Inglés | MEDLINE | ID: mdl-33011144

RESUMEN

OBJECTIVES: The aim of this study was to test the hypothesis that transcatheter electrosurgery might allow intentional detachment of previously placed MitraClip(s) from the anterior leaflet to recreate a single mitral orifice for transcatheter mitral valve implantation (TMVI), leaving the retained MitraClip(s) securely fastened to the posterior leaflet and without interfering with the mitral bioprosthesis. BACKGROUND: Patients with severe mitral regurgitation or stenosis despite edge-to-edge mitral repair with the MitraClip typically have few therapeutic options because the resultant double orifice precludes TMVI. Transcatheter electrosurgery may allow detachment of failed MitraClip(s) from the anterior leaflet to recreate a single orifice for TMVI. METHODS: This was a single-center, 5-patient, consecutive, retrospective observational cohort. Patients underwent transcatheter electrosurgical laceration and stabilization of failed MitraClip(s) to recreate a single orifice, leaving the MitraClip(s) securely fastened to the posterior leaflet. Subsequently, patients underwent TMVI with an investigational device, the Tendyne mitral bioprosthesis, on a compassionate basis. Patients were followed up to 30 days. RESULTS: MitraClip detachment from the anterior leaflet and Tendyne implantation were successful in all patients. All patients survived to discharge. All patients were discharged with grade 0 central mitral regurgitation. Two patients had moderate perivalvular mitral regurgitation that did not require reintervention. During the follow-up period of 30 days, there were no deaths, cases of valve dysfunction, or reintervention. There was no evidence of erosion or bioprosthetic valve dysfunction attributable to the retained MitraClip(s) still attached to the posterior leaflet. CONCLUSIONS: Transcatheter electrosurgical detachment of failed MitraClips from the anterior leaflet followed by TMVI is technically feasible and safe at 30 days. Longer term study is needed to determine the clinical benefit of this approach and new algorithms for TMVI sizing following electrosurgical laceration and stabilization of a failed MitraClip to avoid perivalvular leak.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Anciano , Anciano de 80 o más Años , Antagonistas de Receptores de Angiotensina , Inhibidores de la Enzima Convertidora de Angiotensina , Cateterismo Cardíaco , Electrocirugia , Femenino , Humanos , Masculino , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/cirugía , Estudios Retrospectivos , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA