Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
Europace ; 25(2): 526-535, 2023 02 16.
Artículo en Inglés | MEDLINE | ID: mdl-36480437

RESUMEN

AIMS: Left bundle branch area pacing (LBBAP) is a recent technique aiming at preservation of physiological ventricular electrical activation. Our goal was to assess mechanical synchrony parameters in relation to electrocardiographic features during LBBAP performed in routine practice. METHODS AND RESULTS: From June 2020 to August 2021, all patients of our institution with permanent pacemaker implantation indication were eligible for LBBAP. A 'qR' pattern in V1 and a delay from pacing spike to the peak of the R-wave in V6 < 80 ms defined a successful LBBAP. Electrocardiogram and echocardiography were performed during spontaneous rhythm and LBBAP: left ventricular mechanical synchrony (LVMS) parameters using 2D Speckle tracking and interventricular mechanical delay (IVMD) were collected. LBBAP was attempted with success in 134/163 patients (82.2%). During LBBAP, the mean QRS width was 104 ± 12 ms. In patients with left bundle branch block (n = 47), LBBAP provided a significant decrease of QRS width from 139 ± 16 to 105 ± 12 ms (P < 0.001) with reduction of LVMS (53 ± 21 vs. 90 ± 46 ms, P = 0.009), and IVMD (14 ± 13 vs. 49 ± 18 ms, P < 0.001). In patients with right bundle branch block (n = 38), LBBAP led to a significant decrease of QRS width from 134 ± 14 to 106 ± 13 ms (P < 0.001) with no effect on LVMS and a reduction of IVMD (17 ± 14 vs. 50 ± 16 ms, P < 0.001). CONCLUSION: LBBAP in routine practice preserved intra-ventricular mechanical synchrony in patients with narrow and RBBB QRS and improved asynchrony parameters in patients with LBBB.


Asunto(s)
Bloqueo de Rama , Estimulación Cardíaca Artificial , Humanos , Bloqueo de Rama/diagnóstico por imagen , Bloqueo de Rama/terapia , Estimulación Cardíaca Artificial/métodos , Sistema de Conducción Cardíaco , Electrocardiografía/métodos , Ecocardiografía/métodos , Arritmias Cardíacas , Fascículo Atrioventricular
2.
J Cardiovasc Electrophysiol ; 32(2): 417-427, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33373093

RESUMEN

BACKGROUND: Right ventricular pacing (RVP) induces ventricular asynchrony in patients with normal QRS and increases the risk of heart failure and atrial fibrillation in long term. His bundle pacing (HBP) is a physiological alternative to RVP, and could overcome its drawbacks. Recent studies assessed the feasibility and safety of HBP in expert centers with a vast experience of this technique. These results may not apply to less experienced centers. We aim to evaluate the feasibility and safety of permanent HBP performed by physicians who are new to this technique. METHODS: We included all patients who underwent pacemaker implantation with attempt of HBP in three hospitals between September 2017 and January 2020. Indication for HBP was left to operators' discretion. All the operators were new for HBP. His bundle (HB) electrical parameters were recorded at implant, 3- and 12-month follow-up. RESULTS: HBP was successful in 141 of 170 patients (82.9%); selective HBP was obtained in 96 patients and nonselective HBP in 45. The mean procedure and fluoroscopy durations were 67.0 ± 28.8 min, and 7.3 ± 8.1 min (3.1 ± 4.1 Gy·cm2 ), respectively. The mean HB paced QRS duration was 106 ± 18 ms. The mean HB capture threshold was 1.29 ± 0.77 V and did not increase at 3- and 12-month follow-up. The ventricular lead revision was required in five patients. Our results showed a rapid technical learning allowing a high procedure success rate (89.8%) after 15 procedures. CONCLUSION: HBP performed by operators new to this technique appeared feasible and safe. This should encourage HBP to be performed in patients expected to experience high RVP burden.


Asunto(s)
Fibrilación Atrial , Fascículo Atrioventricular , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/terapia , Estimulación Cardíaca Artificial , Electrocardiografía , Humanos , Sistema de Registros , Resultado del Tratamiento
3.
Europace ; 23(11): 1860-1866, 2021 11 08.
Artículo en Inglés | MEDLINE | ID: mdl-33975338

RESUMEN

AIMS: Although cryoenergy safety profile is appropriate for the ablation of arrhythmogenic foci near the conduction system, mapping using the cryoablation catheter is of limited precision. Combining the safety of cryoenergy and the high precision of a 3D mapping system therefore appears the most appropriate set-up for ablation in the vicinity of the His bundle. METHODS AND RESULTS: A 29-year-old woman with a 3-year history of increasing shortness of breath and palpitations refractory to medical treatment was sent to the electrophysiology (EP) laboratory for catheter ablation. Surface electrocardiogram showed sinus rhythm and frequent ectopic beats with narrow QRS complexes similar to those of the sinus beats. The left ventricular ejection fraction was impaired (38%) with no other aetiology found, apart from frequent ectopies. Detailed intracardiac mapping, using a 3D electroanatomical system, revealed that the ectopy originated from the distal His bundle, which was indicated by both antegrade and reversed His bundle activation sequence during ectopy compared to that during sinus rhythm. Due to the proximity of the conduction system, cryoenergy rather than radiofrequency was chosen to target this Hisian ectopy. A special set-up was made in order to allow the cryoablation catheter to be visualized into the 3D mapping system. Cryoenergy delivered to the site of earliest Hisian ectopy activation completely abolished it. CONCLUSION: Such a combined approach may help to improve the therapeutic strategy for ablation procedures with a high risk of injury to the conduction system. It could notably be extended to the ablation of para-Hisian ectopy or accessory pathways.


Asunto(s)
Fascículo Atrioventricular Accesorio , Ablación por Catéter , Adulto , Fascículo Atrioventricular/cirugía , Ablación por Catéter/métodos , Electrocardiografía , Femenino , Humanos , Volumen Sistólico , Taquicardia , Función Ventricular Izquierda
4.
J Cardiovasc Electrophysiol ; 31(12): 3215-3222, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-33079433

RESUMEN

INTRODUCTION: Either cryoenergy or radiofrequency can be used during atrioventricular nodal reentrant tachycardia (AVNRT) ablation. There are still limited data comparing their respective long-term efficacy (>1 year). This study sought to compare the very long-term outcomes of AVNRT ablation using radiofrequency or cryotherapy. METHODS: We retrospectively included all patients who had undergone a first AVNRT ablation in our institution between January 2010 and December 2017. The primary endpoint was recurrence of documented AVNRT. RESULTS: The study population consisted of 409 patients (274 females; mean age, 49.9 years). Ablation was performed using cryoenergy in 260 patients and radiofrequency in 149. High acute procedural success rate (>98%) was obtained and no permanent AV block was observed using both techniques. During a mean follow-up of 3.3 ± 2.3 years, documented AVNRT recurrence occurred in 24 (9.2%) and 4 patients (2.7%) in the cryoablation (CA) and radiofrequency (RF) group, respectively. The risk of AVNRT recurrence was significantly higher in the CA group as compared with the RF group (hazard ratio [HR] = 3.7; 95% confidence interval [CI], 1.3-5.9). Most of the recurrences after CA occurred between 1- and 6-year follow-up (14/24; 58.3%), with one-third of late recurrences after 3-year follow-up. In multivariable analysis, only Koch's triangle anatomical variant was associated with AVNRT recurrence after CA (HR = 6.7; 95% CI, 2.7-16.3). CONCLUSION: While AVNRT recurrence rates were similar at 1 year of follow-up regardless of the energy used, long-term efficacy appeared higher after radiofrequency ablation. Strikingly, recurrences occured much later after cryotherapy compared with radiofrequency ablation.


Asunto(s)
Ablación por Catéter , Criocirugía , Taquicardia por Reentrada en el Nodo Atrioventricular , Ablación por Catéter/efectos adversos , Criocirugía/efectos adversos , Femenino , Humanos , Persona de Mediana Edad , Recurrencia , Estudios Retrospectivos , Taquicardia por Reentrada en el Nodo Atrioventricular/diagnóstico , Taquicardia por Reentrada en el Nodo Atrioventricular/cirugía , Resultado del Tratamiento
5.
Pacing Clin Electrophysiol ; 41(9): 1178-1184, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-29931693

RESUMEN

BACKGROUND: One of the most frequent complications of transcatheter aortic valve implantation (TAVI) is the occurrence of atrioventricular (AV) conduction disorders secondary to AV node or His bundle injury leading to permanent pacemaker implantation (PPI). The objective was to quantify the rate of ventricular pacing (VP), according to post-TAVI indication for PPI using recorded pacemaker memory. METHODS: From October 2009 to January 2017' all patients who had PPI following TAVI performed at Rouen University Hospital were included. Indications for PPI were: ≥ 1 episode of complete atrioventricular block (CAVB) or 2:1 atrioventricular block, and new-onset persistent left bundle branch block (NOP-LBBB) with either prolonged PR interval (> 200 ms) or HV interval (>70 ms). The primary endpoint was VP percentage at the first pacemaker interrogation (a VP percentage ≥ 1% was considered as significant). RESULTS: Out of 936 TAVI patients (Sapien-3' n = 379 [Edwards Lifesciences, Irvine, CA, USA]; Sapien-XT' n = 513; CoreValve' n = 44, Medtronic, Minneapolis, MN, USA), 87 (9.3%) had PPI. Eighty of these 87 patients were followed-up and analyzed. At the first pacemaker interrogation, a significant VP percentage was observed in 60/80 followed-up patients (75%), in 46/51 patients (90.2%) implanted for CAVB, and 12/23 patients (52.2%) implanted for NOP-LBBB associated with either prolonged PR or HV interval. No clinical predictive factor of significant VP percentage was found. CONCLUSION: In the post-TAVI period, our data support PPI in patients with CAVB even if paroxysmal. Our data also suggest PPI may be considered in patients with NOP-LBBB associated with either prolonged PR or HV interval.


Asunto(s)
Bloqueo Atrioventricular/prevención & control , Marcapaso Artificial , Complicaciones Posoperatorias/prevención & control , Reemplazo de la Válvula Aórtica Transcatéter , Anciano de 80 o más Años , Bloqueo Atrioventricular/fisiopatología , Ecocardiografía , Femenino , Humanos , Masculino , Selección de Paciente , Complicaciones Posoperatorias/fisiopatología
6.
Circ J ; 77(8): 2009-13, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23685707

RESUMEN

BACKGROUND: To gain further insights into mechanisms leading to atrial fibrillation (AF) recurrence after a first ablation procedure using cryoballoon technique, the data collected during redo procedure were analyzed. METHODS AND RESULTS: From a total of 112 patients who underwent cryoballoon pulmonary vein isolation (PVI) for paroxysmal AF, 44 had a second ablation procedure using radiofrequency catheter, because of recurrent atrial arrhythmia. PV reconduction was observed in 109 of the 171 initially isolated veins (64%). Conduction recovery was found, respectively, at the left inferior PV, right inferior PV, right superior PV and left superior PV in 35 patients (80%), 26 patients (67%), 23 patients (52%) and 17 patients (39%). The mean number of reconnected PVs per patient was significantly lower with the 23-mm cryoballoon as compared to the 28-mm. Conduction gaps were focal and located at inferior parts of inferior veins and at the ridge between left atrial appendage and left veins. Mean procedure and fluoroscopy time were 109 ± 32 min and 14.7 ± 8.3 min, respectively. A 3-D mapping system was used in only 8 patients (18%). CONCLUSIONS: Atrial arrhythmia recurrences following cryoballoon PVI were associated with focal PV reconnections, occurring at preferential anatomical sites. These gaps were readily ablated with focal radiofrequency delivery, explaining the lack of need of 3-D mapping system and short procedure time. These results do not support the use of cryoballoon to perform redo procedures.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Venas Pulmonares/cirugía , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
7.
ESC Heart Fail ; 10(3): 2120-2126, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36940720

RESUMEN

AIMS: There are currently limited therapeutic approaches for patients with heart failure with preserved ejection fraction (HFpEF) who have developed permanent atrial fibrillation (AF). We aimed to analyse the impact of ventricular irregularity on heart failure rehospitalization in patients with permanent AF and HFpEF. METHODS AND RESULTS: All 24 h ambulatory Holter monitoring performed in our centre within a month after a first heart failure hospitalization were screened. Patients with HFpEF and permanent AF were included in the retrospective analysis. The following parameters of ventricular irregularity were calculated over the 24 h recording period: standard deviation of all RR intervals (SDNN), coefficient of variation of SDNN (CV-SDNN = SDNN/mean RR), root of the mean squared differences of successive RR intervals (RMSSD), and percentage of consecutive RR intervals with difference over 50 ms (pNN50). The primary endpoint was rehospitalization for acute heart failure (HFrH). From 2010 to 2021, 51/216 screened patients were included. During a median follow-up of 3.13 years, 29/51 patients reached the primary endpoint. HFrH patients had higher SDNN (205 ± 65 vs. 154 ± 46 ms; P < 0.01), CV-SDNN (26 ± 8% vs. 19 ± 5%, P < 0.01), RMSSD (182 ± 47 vs. 138 ± 65 ms, P = 0.013), and pNN50 (76 ± 9 vs. 58 ± 26, P < 0.001) when compared with patients with no HFrH. In multivariate analysis, all those parameters remained significantly associated with HFrH. CONCLUSIONS: In this pilot study, we found some evidences for a deleterious impact of excessive ventricular irregularity on HFrH in AF patients with HFpEF. Those new findings could pave the way for new prognosis and therapeutic approaches in this patients' population.


Asunto(s)
Fibrilación Atrial , Insuficiencia Cardíaca , Humanos , Fibrilación Atrial/complicaciones , Fibrilación Atrial/terapia , Fibrilación Atrial/epidemiología , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/terapia , Volumen Sistólico , Readmisión del Paciente , Frecuencia Cardíaca , Estudios Retrospectivos , Proyectos Piloto
8.
Arch Cardiovasc Dis ; 116(2): 62-68, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36604192

RESUMEN

BACKGROUND: Catheter ablation is a first-line treatment for symptomatic right ventricular outflow tract (RVOT) premature ventricular complexes (PVCs). There is evidence of displacement of the ablation target site during PVCs relative to the location in sinus rhythm (SR). AIM: To analyse the extent of displacement induced by RVOT PVCs and its effect on the ablation sites and the mid-term efficacy of ablation. METHODS: In this multicentre French study, we retrospectively included 18 consecutive adults referred for ablation of RVOT PVCs using a three-dimensional (3D) mapping system. PVC activation maps were performed conventionally (initial map), then each PVC activation point was manually reannotated considering the 3D location on a previous SR beat (corrected map). The ablation-site locations on the initial or the corrected area, including the 10 best activation points, were analysed. Mid-term efficacy was evaluated. RESULTS: The direction of map shift during PVCs relative to the map in SR occurred along a vertical axis in 16 of 18 patients. The mean activation-point displacement for each of the 18 mapped chambers was 5.6±2.2mm. Mid-term recurrence of RVOT PVCs occurred in 5 (28%) patients. In all patients with recurrences, no significant ablation lesion was located on the corrected (true) site of origin. CONCLUSIONS: RVOT PVCs induce a vertical anatomical shift that can mislead physicians about the true location of the arrhythmia's site of origin. Our study highlights the association between mid-term PVC recurrence and the absence of spatial overlap between ablation points and the corrected site of origin.


Asunto(s)
Ablación por Catéter , Complejos Prematuros Ventriculares , Adulto , Humanos , Complejos Prematuros Ventriculares/diagnóstico , Complejos Prematuros Ventriculares/etiología , Complejos Prematuros Ventriculares/cirugía , Estudios Retrospectivos , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Resultado del Tratamiento
9.
Heart Rhythm ; 20(4): 530-536, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36549630

RESUMEN

BACKGROUND: His-bundle pacing (HBP) is an appealing alternative to right ventricular pacing in patients referred for permanent ventricular pacing and atrioventricular nodal ablation (AVNA) because it preserves physiological ventricular activation. Only limited data regarding HBP combined with AVNA are available in the literature. OBJECTIVE: The purpose of this study was to provide further evidence on the feasibility and efficacy of this therapeutic approach in patients with uncontrolled atrial arrhythmia. METHODS: We prospectively included all patients who had undergone AVNA after HBP in 3 different hospitals between 2017 and 2022. RESULTS: AVNA following HBP lead implantation was performed in 75 patients. Complete atrioventricular (AV) block was obtained in 58 patients (77%), and significant modulation of AV nodal conduction (heart rate <60 bpm) was obtained in 12 patients (16%). AVNA failure was observed in 5 patients (7%). Recording of an atrial signal by the HBP lead was more frequently observed in patients with AVNA modulation/failure than in patients with complete AV block (11/17 vs 5/58; P <.001). No lead dislodgment occurred during the AVNA procedures. Acute His-bundle (HB) capture threshold increase >1 V occurred in 11 patients (15%), with return to baseline value on day 1 in 9 patients. New York Heart Association functional class and left ventricular ejection fraction significantly improved from baseline to last follow-up (3.0 ± 0.7 vs 1.6 ± 0.5; P <.001; and 47% ± 14% vs 60% ± 9%; P <.0001, respectively). CONCLUSION: AVNA combined with HBP for noncontrolled atrial arrhythmia was feasible and clinically efficient. Implanting the HB lead on the ventricular aspect of the tricuspid annulus avoiding atrial signal recording can facilitate AVNA.


Asunto(s)
Fibrilación Atrial , Bloqueo Atrioventricular , Humanos , Fibrilación Atrial/cirugía , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda , Estimulación Cardíaca Artificial/métodos , Fascículo Atrioventricular
10.
J Cardiovasc Electrophysiol ; 23(4): 346-51, 2012 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-22081875

RESUMEN

INTRODUCTION: Various types of complications have been reported after atrial fibrillation (AF) ablation using radiofrequency energy, but those have not been well defined when using cryoballoon ablation technique. The objective of this prospective study was to assess types, incidence, and outcome of complications after cryoballoon pulmonary vein isolation (PVI). METHODS AND RESULTS: This prospective monocentric study included 66 consecutive patients (39 males, age 57 ± 11 years) who underwent cryoballoon PVI for symptomatic paroxysmal AF. Phrenic nerve (PN) integrity was assessed by pacing from the superior vena cava during isolation of the right PVs. Before discharge, all patients were subjected to 24-hour Holter electrocardiograms, echocardiography, and esophagogastroduodenoscopy. Cardiac MRI was scheduled between 1 and 3 months postprocedure. At 3.7 ± 1.7 months after ablation, patients underwent clinical review and 24-hour Holter electrocardiograms. The mean number of cryoballoon applications was 10.0 ± 2.1 per patient and 2.5 ± 1.0 per vein. A 28 mm cryoballoon was used in 49 patients (74%) and a 23 mm cryoballoon in the remaining 17 patients (26%). Twelve complications (18%) attributing to collateral nervous damage were noticed in 9 patients: asymptomatic gastroparesis was observed in 6 patients (9%), transient PN palsy (PNP) in 5 (8%), and symptomatic inappropriate sinus tachycardia requiring beta-blocker treatment in 1 (1%). Neither cryoballoon-related esophageal ulceration nor PV stenosis was observed. CONCLUSION: Gastroparesis and PNP could be observed in a significant number of cases after cryoballoon ablation of AF. These complications are likely due to cryo-induced damages to nervous structures surrounding the heart.


Asunto(s)
Fibrilación Atrial/cirugía , Criocirugía/efectos adversos , Traumatismos de los Nervios Periféricos/etiología , Venas Pulmonares/cirugía , Agonistas Adrenérgicos beta/uso terapéutico , Adulto , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Distribución de Chi-Cuadrado , Ecocardiografía , Electrocardiografía Ambulatoria , Endoscopía del Sistema Digestivo , Femenino , Francia , Gastroparesia/etiología , Humanos , Modelos Logísticos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Oportunidad Relativa , Parálisis/etiología , Traumatismos de los Nervios Periféricos/diagnóstico , Traumatismos de los Nervios Periféricos/tratamiento farmacológico , Nervio Frénico/lesiones , Valor Predictivo de las Pruebas , Estudios Prospectivos , Venas Pulmonares/fisiopatología , Medición de Riesgo , Factores de Riesgo , Taquicardia Sinusal/tratamiento farmacológico , Taquicardia Sinusal/etiología , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
11.
J Cardiovasc Electrophysiol ; 23(7): 778-80, 2012 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-22783945

RESUMEN

Left phrenic nerve stimulation is a well-known complication of cardiac resynchronization therapy (CRT). We report a case where electronic or anatomical repositioning of the left ventricular (LV) electrode (within the coronary sinus tributaries) was not feasible/effective. Surgical graft interpositioning was performed to successfully isolate the phrenic nerve from the previously implanted coronary sinus epicardial LV lead.


Asunto(s)
Bloqueo de Rama/terapia , Terapia de Resincronización Cardíaca/efectos adversos , Diafragma/inervación , Contracción Muscular , Nervio Frénico/cirugía , Toracoscopía , Dispositivos de Terapia de Resincronización Cardíaca , Diseño de Equipo , Humanos , Masculino , Persona de Mediana Edad , Nervio Frénico/diagnóstico por imagen , Toracoscopía/instrumentación , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
12.
Europace ; 13(11): 1659-60, 2011 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-21712279

RESUMEN

A dual-chamber pacemaker was implanted because of symptomatic bradycardia in a 60-year-old patient free from other heart disease. Then, the patient developed acute congestive heart failure due to pacing-induced mitral regurgitation (MR). Under echocardiographic guidance, modification of location of the right ventricular pacing lead led to a significant decrease in MR severity resulting in immediate clinical improvement.


Asunto(s)
Estimulación Cardíaca Artificial/métodos , Insuficiencia de la Válvula Mitral/terapia , Marcapaso Artificial , Disfunción Ventricular Derecha/fisiopatología , Bradicardia/terapia , Ecocardiografía , Insuficiencia Cardíaca/etiología , Humanos , Masculino , Persona de Mediana Edad , Insuficiencia de la Válvula Mitral/complicaciones , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Resultado del Tratamiento , Disfunción Ventricular Derecha/diagnóstico por imagen , Tabique Interventricular/diagnóstico por imagen , Tabique Interventricular/fisiopatología
13.
Europace ; 13(4): 593-5, 2011 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-21076145

RESUMEN

Seven years after the implantation of a dual-chamber pacemaker, a 74-year-old woman was referred for syncope. Chest X-ray revealed that the ventricular lead was completely broken near the tricuspid valve. Fluoroscopy and transthoracic echocardiography found a calcified mass, moving with the proximal part of the ventricular lead. Anatomopathology of the atrial tumour remained unknown. Surgery was considered too invasive a technique to be performed in our patient, who was suffering from dementia.


Asunto(s)
Electrodos Implantados/efectos adversos , Falla de Equipo , Neoplasias Cardíacas/complicaciones , Marcapaso Artificial/efectos adversos , Síncope/etiología , Anciano , Procedimientos Quirúrgicos Cardiovasculares , Contraindicaciones , Demencia/complicaciones , Ecocardiografía , Femenino , Atrios Cardíacos/diagnóstico por imagen , Neoplasias Cardíacas/diagnóstico por imagen , Humanos , Síncope/diagnóstico
14.
Eur J Sport Sci ; 21(3): 439-449, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-32223533

RESUMEN

AbstractBreath-hold divers are known to develop cardiac autonomic changes and brady-arrthymias during prolonged breath-holding (BH). The effects of BH-induced hypoxemia were investigated upon both cardiac autonomic status and arrhythmogenesis by comparing breath-hold divers (BHDs) to non-divers (NDs). Eighteen participants (9 BHDs, 9 NDs) performed a maximal voluntary BH with face immersion. BHDs were asked to perform an additional BH at water surface to increase the degree of hypoxemia. Beat-to-beat changes in heart rate (HR), short-term fractal scaling exponent (DFAα1), the number of arrhythmic events [premature ventricular contractions (PVCs), premature atrial contractions (PACs)] and peripheral oxygen saturation (SpO2) were recorded during and immediately following BH. The corrected QT-intervals (QTc) were analyzed pre- and post-acute BH. A regression-based model was used to split BH into a normoxic (NX) and a hypoxemic phase (HX). During the HX phase of BH, BHDs showed a progressive decrease in DFAα1 during BH with face immersion (p < 0.01) and BH with whole-body immersion (p < 0.01) whereas NDs did not (p > 0.05). In addition, BHDs had more arrhythmic events during the HX of BH with whole-body immersion when compared to the corresponding NX phase (5.9 ± 6.7 vs 0.4 ± 1.3; p < 0.05; respectively). The number of PVCs was negatively correlated with SpO2 during BH with whole-body immersion (r = -0.72; p < 0.05). The hypoxemic stage of voluntary BH is concomitant with significant cardiac autonomic changes toward a synergistic sympathetic and parasympathetic stimulation. Co-activation led ultimately to increased bradycardic response and cardiac electrophysiological disturbances.


Asunto(s)
Arritmias Cardíacas/etiología , Sistema Nervioso Autónomo/fisiología , Contencion de la Respiración , Buceo/fisiología , Frecuencia Cardíaca/fisiología , Hipoxia/fisiopatología , Adulto , Análisis de Varianza , Complejos Atriales Prematuros/fisiopatología , Reflejo de Inmersión/fisiología , Humanos , Inmersión/fisiopatología , Masculino , Oxígeno/metabolismo , Análisis de Regresión , Complejos Prematuros Ventriculares/fisiopatología
15.
Arch Cardiovasc Dis ; 114(2): 105-114, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33129697

RESUMEN

BACKGROUND: Cryoballoon ablation is an effective procedure to treat atrial fibrillation (AF). However, AF recurrence rate at 1-year follow-up is approximately 20% despite improvements in ablation technique. AIM: To find factors predictive of AF recurrence following a first pulmonary vein isolation procedure using a second-generation cryoballoon (PVI-2CB). METHODS: This was an observational, retrospective, single-centre study. From June 2012 to April 2017, all patients who had a PVI-2CB procedure and a scheduled follow-up at Rouen University Hospital were included. The primary endpoint was atrial arrhythmia (AA) recurrence (e.g. AF, flutter or tachycardia), considering a blanking period of 2 months following the procedure. Secondary endpoints were procedural variables for each pulmonary vein (successful isolation, time to disconnection, total cryoballoon application time, number of cryoballoon applications, level of occlusion during cryoballoon application leading to successful disconnection and lowest temperature reached during successful cryoballoon application), occurrence of redo procedures, use of antiarrhythmic drugs and adverse events. RESULTS: The initial population consisted of 239 patients; six were excluded for lack of procedural variable data, giving an analysed population of 233 patients. The AA recurrence rate was 36.9% (mean follow-up 25±14 months). Mean time to AA recurrence was 10±12 months. No procedural variable was found to be predictive of AA recurrence. Only major left atrial enlargement (defined as diameter>50mm or left atrial area>30cm2 or left atrial volume>50mL/m2) was predictive (odds ratio 2.70, 95% confidence interval 1.54-4.72; P=0.001). Forty-one patients had redo procedures (17.6% of analysed population); in this subgroup, 75.6% had at least one pulmonary vein reconnected, mainly the right inferior pulmonary vein. CONCLUSIONS: At long-term follow-up, up to one-third of patients had AA recurrence after PVI-2CB. Important atrial remodelling was the only factor predictive of AA recurrence, whereas no procedural variable was found to be predictive.


Asunto(s)
Fibrilación Atrial/cirugía , Criocirugía/efectos adversos , Venas Pulmonares/cirugía , Potenciales de Acción , Anciano , Antiarrítmicos/uso terapéutico , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Aleteo Atrial/etiología , Aleteo Atrial/cirugía , Femenino , Francia , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Venas Pulmonares/fisiopatología , Recurrencia , Reoperación , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Taquicardia Supraventricular/etiología , Taquicardia Supraventricular/cirugía , Factores de Tiempo , Resultado del Tratamiento
16.
Arch Cardiovasc Dis ; 112(5): 314-322, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-30670363

RESUMEN

BACKGROUND: Atrial fibrillation is the most common arrhythmia in adults. A relationship between epicardial adipose tissue and atrial fibrillation has recently been reported. AIM: To evaluate the impact of epicardial fat thickness on the outcome of patients who underwent a first pulmonary vein isolation procedure using a second-generation cryoballoon. METHODS: From February 2012 to February 2017, all patients who underwent a first pulmonary vein isolation procedure using a second-generation cryoballoon at Rouen University Hospital were included. Data were collected retrospectively. Epicardial fat thickness was assessed by cardiac magnetic resonance imaging. The primary endpoint was documented atrial fibrillation recurrence at 4 months. RESULTS: A first pulmonary vein isolation procedure using a second-generation cryoballoon was performed in 288 patients; among them, 231 patients (80.2%) underwent cardiac magnetic resonance imaging. Epicardial fat thickness could be measured accurately in 206 patients (71.5%). Recurrence of atrial fibrillation at 4 months occurred in 32/206 patients (15.5%). In the multivariable analysis, factors predictive of atrial fibrillation recurrence at 4 months were: epicardial fat thickness (hazard ratio 1.96, 95% confidence interval 1.20-3.18; P=0.007), the presence of high left atrium enlargement (hazard ratio 4.63, 95% confidence interval 1.17-18.38; P=0.03) and atrial fibrillation recurrence before hospital discharge (hazard ratio 7.55, 95% confidence interval 2.50-22.81; P<0.001). CONCLUSION: Epicardial fat thickness is a predictive factor for atrial fibrillation recurrence after a first pulmonary vein isolation procedure using a second-generation cryoballoon.


Asunto(s)
Tejido Adiposo/fisiopatología , Adiposidad , Fibrilación Atrial/cirugía , Catéteres Cardíacos , Criocirugía/instrumentación , Pericardio/fisiopatología , Venas Pulmonares/cirugía , Tejido Adiposo/diagnóstico por imagen , Anciano , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/fisiopatología , Criocirugía/efectos adversos , Diseño de Equipo , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Pericardio/diagnóstico por imagen , Venas Pulmonares/fisiopatología , Recurrencia , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
17.
Heart Rhythm ; 10(10): 1492-8, 2013 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23811080

RESUMEN

BACKGROUND: Sudden cardiac death is frequent in patients with lamin A/C gene (LMNA) mutations and may be related to ventricular arrhythmias (VA). OBJECTIVE: To evaluate a strategy of prophylactic implantable cardioverter-defibrillator (ICD) implantation in LMNA mutation carriers with significant cardiac conduction disorders. METHODS: Forty-seven consecutive patients (mean age 38 ± 11 years; 26 men) were prospectively enrolled between March 1999 and April 2009. Prophylactic ICD implantation was performed in patients with significant cardiac conduction disorders: patients requiring permanent pacing for bradycardia or already implanted with a pacemaker at the initial presentation, or patients with a PR interval of >0.24 seconds and either complete left bundle branch block or nonsustained ventricular tachycardia. RESULTS: Twenty-one (45%) patients had significant conduction disorders and received a prophylactic ICD. Among ICD recipients, no patient died suddenly and 11 (52%) patients required appropriate ICD therapy during a median follow-up of 62 months. Left ventricular ejection fraction was ≥45% in 9 patients at the time of the event. Among the 10 patients without malignant VA, device memory recorded nonsustained ventricular tachycardia in 8 (80%). The presence of significant conduction disorders was the only factor related to the occurrence of malignant VA (hazard ratio 5.20; 95% confidence interval 1.14-23.53; P = .03). CONCLUSIONS: Life-threatening VAs are common in patients with LMNA mutations and significant cardiac conduction disorders, even if left ventricular ejection fraction is preserved. ICD is an effective treatment and should be considered in this patient population.


Asunto(s)
Arritmias Cardíacas/genética , Arritmias Cardíacas/terapia , Sistema de Conducción Cardíaco/anomalías , Lamina Tipo A/genética , Mutación/genética , Taquicardia Ventricular/prevención & control , Fibrilación Ventricular/prevención & control , Adulto , Arritmias Cardíacas/complicaciones , Síndrome de Brugada , Trastorno del Sistema de Conducción Cardíaco , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Taquicardia Ventricular/etiología , Fibrilación Ventricular/etiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA