Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Synchrotron Radiat ; 31(Pt 5): 1161-1167, 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-39102363

RESUMEN

Modeling the behavior of a prototype cantilevered X-ray adaptive mirror (held from one end) demonstrates its potential for use on high-performance X-ray beamlines. Similar adaptive mirrors are used on X-ray beamlines to compensate optical aberrations, control wavefronts and tune mirror focal distances at will. Controlled by 1D arrays of piezoceramic actuators, these glancing-incidence mirrors can provide nanometre-scale surface shape adjustment capabilities. However, significant engineering challenges remain for mounting them with low distortion and low environmental sensitivity. Finite-element analysis is used to predict the micron-scale full actuation surface shape from each channel and then linear modeling is applied to investigate the mirrors' ability to reach target profiles. Using either uniform or arbitrary spatial weighting, actuator voltages are optimized using a Moore-Penrose matrix inverse, or pseudoinverse, revealing a spatial dependence on the shape fitting with increasing fidelity farther from the mount.

2.
J Synchrotron Radiat ; 30(Pt 3): 514-518, 2023 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-36897396

RESUMEN

Mirror-centered, closed-form expressions for hyperbolic surfaces used in X-ray beamlines have been derived. Hyperbolic mirrors create a virtual focus or source point and can be used to lengthen or shorten the effective focal distance of a compound optical system. The derivations here express off-axis segments of a hyperbolic surface in terms of the real and virtual focal distances and the incident glancing angle at the center of the mirror. Conventional mathematical expressions of hyperbolic shapes describe the surfaces in Cartesian or polar coordinates centered on an axis of symmetry, necessitating cumbersome rotation and translation to mirror-centered coordinates. The representation presented here, with zero slope and the origin at the central point, is most convenient for modeling, metrology, aberration correction, and general surface analysis of off-axis configurations. The direct derivation avoids the need for nested coordinate transforms. A series expansion provides a helpful approximation; the coefficients of the implicit equation are also provided.

3.
J Synchrotron Radiat ; 30(Pt 1): 57-64, 2023 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-36601926

RESUMEN

Adaptive X-ray mirrors are being adopted on high-coherent-flux synchrotron and X-ray free-electron laser beamlines where dynamic phase control and aberration compensation are necessary to preserve wavefront quality from source to sample, yet challenging to achieve. Additional difficulties arise from the inability to continuously probe the wavefront in this context, which demands methods of control that require little to no feedback. In this work, a data-driven approach to the control of adaptive X-ray optics with piezo-bimorph actuators is demonstrated. This approach approximates the non-linear system dynamics with a discrete-time model using random mirror shapes and interferometric measurements as training data. For mirrors of this type, prior states and voltage inputs affect the shape-change trajectory, and therefore must be included in the model. Without the need for assumed physical models of the mirror's behavior, the generality of the neural network structure accommodates drift, creep and hysteresis, and enables a control algorithm that achieves shape control and stability below 2 nm RMS. Using a prototype mirror and ex situ metrology, it is shown that the accuracy of our trained model enables open-loop shape control across a diverse set of states and that the control algorithm achieves shape error magnitudes that fall within diffraction-limited performance.

4.
Opt Express ; 31(13): 21264-21279, 2023 Jun 19.
Artículo en Inglés | MEDLINE | ID: mdl-37381230

RESUMEN

A neural-network machine learning model is developed to control a bimorph adaptive mirror to achieve and preserve aberration-free coherent X-ray wavefronts at synchrotron radiation and free electron laser beamlines. The controller is trained on a mirror actuator response directly measured at a beamline with a real-time single-shot wavefront sensor, which uses a coded mask and wavelet-transform analysis. The system has been successfully tested on a bimorph deformable mirror at the 28-ID IDEA beamline of the Advanced Photon Source at Argonne National Laboratory. It achieved a response time of a few seconds and maintained desired wavefront shapes (e.g., a spherical wavefront) with sub-wavelength accuracy at 20 keV of X-ray energy. This result is significantly better than what can be obtained using a linear model of the mirror's response. The developed system has not been tailored to a specific mirror and can be applied, in principle, to different kinds of bending mechanisms and actuators.

5.
J Synchrotron Radiat ; 29(Pt 4): 985-990, 2022 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-35787564

RESUMEN

On X-ray beamlines and telescopes, glancing-incidence mirrors with parabolic profiles are used to collimate, focus, and collect light. Here, analytic descriptions for paraboloidal, plane-parabolic, and parabolic cylindrical mirrors in several congruent geometries that are commonly used in fabrication, metrology, and modeling are provided. The exact expressions are derived directly from Fermat's principle, without coordinate transformations, in several mirror-centered coordinate systems, including one with the surface tangent to the central point of intersection. Coefficients for a sixth-order polynomial series approximation are calculated for that coordinate system.

6.
J Synchrotron Radiat ; 29(Pt 4): 991-996, 2022 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-35787565

RESUMEN

Ellipsoidal and plane-elliptical surfaces are widely used as reflective, point-to-point focusing elements in many optical systems, including X-ray optics. Here the classical optical path function approach of Fermat is applied to derive a closed-form expression for these surfaces that are uniquely described by the object and image distances and the angle of incidence at a point on a mirror surface. A compact description facilitates design, modeling, fabrication, and testing to arbitrary accuracy. Congruent surfaces in two useful coordinate systems - a system centered on the ellipsoid's axes of symmetry and a mirror-centered or `vertex' system with the surface tangent to the xy plane at the mirror's center - are presented. Expressions for the local slope and radii of curvature are derived from the result, and the first several terms of the Maclauren series expansion are provided about the mirror center.

7.
J Synchrotron Radiat ; 28(Pt 4): 1041-1049, 2021 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-34212867

RESUMEN

The diaboloid is a reflecting surface that converts a spherical wave to a cylindrical wave. This complex surface may find application in new Advanced Light Source bending-magnet beamlines or in other beamlines that now use toroidal optics for astigmatic focusing. Here, the numerical implementation of diaboloid mirrors is described, and the benefit of this mirror in beamlines exploiting diffraction-limited storage rings is studied by ray tracing. The use of diaboloids becomes especially interesting for the new low-emittance storage rings because the reduction of aberration becomes essential for such small sources. The validity of the toroidal and other mirror surfaces approximating the diaboloid, and the effect of the mirror magnification, are discussed.

8.
J Synchrotron Radiat ; 28(Pt 4): 1031-1040, 2021 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-34212866

RESUMEN

A new type of optical element that can focus a cylindrical wave to a point focus (or vice versa) is analytically described. Such waves are, for example, produced in a beamline where light is collimated in one direction and then doubly focused by a single optic. A classical example in X-ray optics is the collimated two-crystal monochromator, with toroidal mirror refocusing. The element here replaces the toroid, and in such a system provides completely aberration free, point-to-point imaging of rays from the on-axis source point. We present an analytic solution for the mirror shape in its laboratory coordinate system with zero slope at the centre, and approximate solutions, based on bending an oblique circular cone and a bent right circular cylinder, that may facilitate fabrication and metrology.

9.
J Urol ; 206(3): 715-724, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-33872051

RESUMEN

PURPOSE: We present final 5-year outcomes of the multicenter randomized sham-controlled trial of a water vapor therapy (Rezum™) for treatment of moderate to severe lower urinary tract symptoms due to benign prostatic hyperplasia. MATERIALS AND METHODS: A total of 197 subjects >50 years of age with International Prostate Symptom Score ≥13, maximum flow rate ≤15 ml/second and prostate volume 30 to 80 cc were randomized and followed for 5 years. From the control arm of 61 subjects, a subset of 53 subjects requalified and after 3 months received treatment as part of the crossover group and were also followed for 5 years. The total number of vapor treatments to each lobe of the prostate was determined by length of prostatic urethra and included middle lobe treatment per physician discretion. RESULTS: Significant improvement of lower urinary tract symptoms was observed at <3 months post-thermal therapy, remaining durable through 5 years in the treatment group (International Prostate Symptom Score reduced 48%, quality of life increased 45%, maximum flow rate improved 44%, Benign Prostatic Hyperplasia Impact Index decreased 48%). Surgical re-treatment rate was 4.4% with no reports of device or procedure related sexual dysfunction or sustained de novo erectile dysfunction. Results within the crossover group were similar through 5 years. CONCLUSIONS: Minimally invasive treatment with water vapor thermal therapy provides significant and durable symptom relief as well as flow rate improvements through 5 years, with low surgical re-treatment rates and without impacting sexual function. It is a versatile therapy, providing successful treatment to obstructive lateral and middle lobes.


Asunto(s)
Hipertermia Inducida/métodos , Síntomas del Sistema Urinario Inferior/terapia , Hiperplasia Prostática/terapia , Anciano , Estudios Cruzados , Disfunción Eréctil/epidemiología , Disfunción Eréctil/etiología , Estudios de Seguimiento , Humanos , Hipertermia Inducida/efectos adversos , Hipertermia Inducida/estadística & datos numéricos , Síntomas del Sistema Urinario Inferior/diagnóstico , Síntomas del Sistema Urinario Inferior/etiología , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Hiperplasia Prostática/complicaciones , Calidad de Vida , Retratamiento/estadística & datos numéricos , Índice de Severidad de la Enfermedad , Disfunciones Sexuales Fisiológicas/epidemiología , Disfunciones Sexuales Fisiológicas/etiología , Vapor , Estados Unidos
10.
Opt Lett ; 46(4): 729-732, 2021 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-33577500

RESUMEN

Now in use on x-ray beamlines worldwide, shearing interferometry and Hartmann wavefront sensing provide effective feedback for measuring and optimizing high-quality beams. Conventionally, both approaches spatially modulate the beam properties (amplitude or phase) using two-tone, binary patterns, leading to deleterious diffraction effects that must be mitigated. In shearing, the presence of multiple diffraction orders affects measurement near boundaries. In Hartmann, diffraction limits the measurement point density. We demonstrate that the use of pseudo-gray-scale halftone patterns in the diffracting elements can improve the performance of both techniques.

11.
Sensors (Basel) ; 21(2)2021 Jan 13.
Artículo en Inglés | MEDLINE | ID: mdl-33451025

RESUMEN

New, high-coherent-flux X-ray beamlines at synchrotron and free-electron laser light sources rely on wavefront sensors to achieve and maintain optimal alignment under dynamic operating conditions. This includes feedback to adaptive X-ray optics. We describe the design and modeling of a new class of binary-amplitude reflective gratings for shearing interferometry and Hartmann wavefront sensing. Compact arrays of deeply etched gratings illuminated at glancing incidence can withstand higher power densities than transmission membranes and can be designed to operate across a broad range of photon energies with a fixed grating-to-detector distance. Coherent wave-propagation is used to study the energy bandwidth of individual elements in an array and to set the design parameters. We observe that shearing operates well over a ±10% bandwidth, while Hartmann can be extended to ±30% or more, in our configuration. We apply this methodology to the design of a wavefront sensor for a soft X-ray beamline operating from 230 eV to 1400 eV and model shearing and Hartmann tests in the presence of varying wavefront aberration types and magnitudes.

12.
J Synchrotron Radiat ; 27(Pt 5): 1141-1152, 2020 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-32876588

RESUMEN

A realistic wave optics simulation method has been developed to study how wavefront distortions originating from heat load deformations can be corrected using adaptive X-ray optics. Several planned soft X-ray and tender X-ray insertion-device beamlines in the Advanced Light Source upgrade rely on a common design principle. A flat, first mirror intercepts the white beam; vertical focusing is provided by a variable-line-space monochromator; and horizontal focusing comes from a single, pre-figured, adaptive mirror. A variety of scenarios to cope with thermal distortion in the first mirror are studied by finite-element analysis. The degradation of the intensity distribution at the focal plane is analyzed and the adaptive optics that correct it is modeled. The range of correctable wavefront errors across the operating range of the beamlines is reported in terms of mirror curvature and spatial frequencies. The software developed is a one-dimensional wavefront propagation package made available in the OASYS suite, an adaptable, customizable and efficient beamline modeling platform.

13.
Opt Express ; 28(13): 19242-19254, 2020 Jun 22.
Artículo en Inglés | MEDLINE | ID: mdl-32672205

RESUMEN

This article describes the development and testing of a novel, water-cooled, active optic mirror system (called "REAL: Resistive Element Adjustable Length") that combines cooling with applied auxiliary heating, tailored to the spatial distribution of the thermal load generated by the incident beam. This technique is theoretically capable of sub-nanometer surface figure error control even at high power density. Tests conducted in an optical metrology laboratory and at synchrotron X-ray beamlines showed the ability to maintain the mirror profile to the level needed for the next generation storage rings and FEL mirrors.

14.
Opt Lett ; 45(17): 4694-4697, 2020 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-32870834

RESUMEN

We demonstrate a reflective wavefront sensor grating suitable for the characterization of high-quality x-ray beamlines and optical systems with high power densities. Operating at glancing incidence angles, the optical element is deeply etched with a two-level pattern of shearing interferometry gratings and Hartmann wavefront sensor grids. Transverse features block unwanted light, enabling binary amplitude in reflection with high pattern contrast. We present surface characterization and soft x-ray reflectometry of a prototype grating array to demonstrate function prior to wavefront measurement applications. A simulation of device performance is shown.

15.
J Urol ; 197(6): 1507-1516, 2017 06.
Artículo en Inglés | MEDLINE | ID: mdl-27993667

RESUMEN

PURPOSE: We report 2-year outcomes of a multicenter randomized controlled trial plus 1-year results of a crossover trial after treatment with convective radiofrequency water vapor thermal energy for lower urinary tract symptoms due to benign prostatic hyperplasia. MATERIALS AND METHODS: A total of 197 men at least 50 years old with I-PSS (International Prostate Symptom Score) 13 or greater, maximum flow rate 15 ml per second or less and prostate size 30 to 80 cc were randomized 2:1 to thermal therapy with the Rezum® System or a control group. Rigid cystoscopy with simulated active treatment sounds served as the control procedure. After unblinding at 3 months control subjects could requalify for crossover study. Convectively delivered radiofrequency thermal energy was delivered into obstructive prostate tissue, including the median lobe as needed. The primary efficacy end point was a change in severity of symptom scores. RESULTS: Convective radiofrequency thermal therapy improved urinary symptoms significantly over controls at 3 months and provided a sustained 51% reduction from baseline at 24 months (p <0.0001). This produced a 5 and 8-point or greater score decrease in 84% and 74% of subjects, respectively, at 24 months. Crossover subject symptoms, flow rate and quality of life measures were markedly improved after thermal therapy compared to after the control procedure (p = 0.024 to <0.0001). No de novo erectile dysfunction was reported. CONCLUSIONS: Convective radiofrequency water vapor thermal therapy is a minimally invasive office or outpatient procedure that provides early effective symptom relief that remains durable for 2 years and is applicable to the median lobe.


Asunto(s)
Síntomas del Sistema Urinario Inferior/terapia , Terapia por Radiofrecuencia , Convección , Estudios Cruzados , Método Doble Ciego , Humanos , Síntomas del Sistema Urinario Inferior/etiología , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Hiperplasia Prostática/complicaciones , Terapia por Radiofrecuencia/métodos , Factores de Tiempo , Resultado del Tratamiento
16.
Appl Opt ; 56(12): 3325-3328, 2017 Apr 20.
Artículo en Inglés | MEDLINE | ID: mdl-28430243

RESUMEN

It is now well established that extreme ultraviolet (EUV) mask multilayer roughness leads to wafer-plane line-width roughness (LWR) in the lithography process. Analysis and modeling done to date has assumed, however, that the roughness leading to scatter is primarily a phase effect and that the amplitude can be ignored. Under this assumption, simple scattering measurements can be used to characterize the statistical properties of the mask roughness. Here, we explore the implications of this simplifying assumption by modeling the imaging impacts of the roughness amplitude component as a function of the balance between amplitude and phase induced scatter. In addition to model-based analysis, we also use an EUV microscope to compare experimental through focus data to modeling in order to assess the actual amount of amplitude roughness on a typical EUV multilayer mask. The results indicate that amplitude roughness accounts for less than 1% of the total scatter for typical EUV masks.

17.
J Urol ; 195(5): 1529-1538, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-26614889

RESUMEN

PURPOSE: This report reveals the results of a multicenter, randomized, controlled study using transurethral prostate convective water vapor thermal energy to treat lower urinary tract symptoms associated with benign prostatic hyperplasia. MATERIALS AND METHODS: Men 50 years old or older with an International Prostate Symptom Score of 13 or greater, maximum flow rate of 15 ml per second or less and prostate size 30 to 80 cc were randomized 2:1 between thermal therapy with the Rezum® System and control. Thermal water vapor was injected into the transition zone and median lobe as needed. The control procedure was rigid cystoscopy with simulated active treatment sounds. The primary end point compared International Prostate Symptom Score reduction at 3 months. Treatment subjects were followed for 12 months. RESULTS: There were 197 men randomized (active 136, control 61). Thermal therapy and control International Prostate Symptom Score was reduced by 11.2 ± 7.6 and 4.3 ± 6.9 respectively (p <0.0001). Treatment subject baseline International Prostate Symptom Score of 22 decreased at 2 weeks (18.6, p=0.0006) and by 50% or greater at 3, 6 and 12 months, p <0.0001. The peak flow rate increased by 6.2 ml per second at 3 months and was sustained throughout 12 months (p <0.0001). No de novo erectile dysfunction was reported. Adverse events were mild to moderate and resolved quickly. CONCLUSIONS: Convective water vapor thermal therapy provides rapid and durable improvements in benign prostatic hyperplasia symptoms and preserves erectile and ejaculatory function. Treatment can be delivered in an office or hospital setting using oral pain medication and is applicable to all prostate zones including the median lobe.


Asunto(s)
Hipertermia Inducida/métodos , Síntomas del Sistema Urinario Inferior/cirugía , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Hiperplasia Prostática/cirugía , Resección Transuretral de la Próstata/métodos , Urodinámica/fisiología , Cistoscopía , Método Doble Ciego , Estudios de Seguimiento , Humanos , Síntomas del Sistema Urinario Inferior/etiología , Síntomas del Sistema Urinario Inferior/fisiopatología , Masculino , Persona de Mediana Edad , Hiperplasia Prostática/complicaciones , Hiperplasia Prostática/diagnóstico , Vapor , Factores de Tiempo , Resultado del Tratamiento
19.
J Sex Med ; 13(6): 924-33, 2016 06.
Artículo en Inglés | MEDLINE | ID: mdl-27129767

RESUMEN

INTRODUCTION: Most surgical treatments for male lower urinary tract symptoms and benign prostatic hyperplasia affect erectile and ejaculatory functions negatively, leading to patient dissatisfaction. AIM: To determine whether water vapor thermal therapy, when conducted in a randomized controlled trial, would significantly improve lower urinary tract symptoms secondary to benign prostatic hyperplasia and urinary flow rate while preserving erectile and ejaculatory functions. METHODS: Men at least 50 years old with International Prostate Symptom Scores of at least 13, a peak flow rate of at least 5 to no higher than 15 mL/s, and prostate volume of 30 to 80 cm(3) were randomized 2:1 between Rezum System thermal therapy and control. Thermal water vapor (103°C) was injected into lateral and median lobes as required for treatment of benign prostatic hyperplasia. The control procedure entailed rigid cystoscopy with simulated active treatment sounds. MAIN OUTCOME MEASURES: Blinded group (active = 136, control = 61) comparison occurred at 3 months and the active arm was followed to 12 months for International Prostate Symptom Score, peak flow rate, and sexual function using the International Index of Erectile Function and the Male Sexual Health Questionnaire for Ejaculatory Function. The minimal clinically important difference in erectile function perceived by subjects as beneficial was determined for each erectile function severity category. Subjects not sexually active were censored from sexual function analysis. RESULTS: No treatment- or device-related de novo erectile dysfunction occurred after thermal therapy. International Index of Erectile Function and Male Sexual Health Questionnaire for Ejaculatory Function scores were not different from the control group at 3 months or from baseline at 1 year. Ejaculatory bother score improved 31% over baseline (P = .0011). Also, 32% of subjects achieved minimal clinically important differences in erectile function scores at 3 months, and 27% at 1 year, including those with moderate to severe erectile dysfunction. International Prostate Symptom Score and peak flow rate were significantly superior to controls at 3 months and throughout 1 year (P < .0001). CONCLUSION: Convective water vapor thermal therapy provides sustainable improvements for 12 months to lower urinary tract symptoms and urinary flow while preserving erectile and ejaculatory functions.


Asunto(s)
Síntomas del Sistema Urinario Inferior/terapia , Erección Peniana , Hiperplasia Prostática/complicaciones , Anciano , Anciano de 80 o más Años , Cistoscopía , Método Doble Ciego , Eyaculación , Disfunción Eréctil/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Vapor , Encuestas y Cuestionarios , Resultado del Tratamiento
20.
Opt Express ; 22(17): 20144-54, 2014 Aug 25.
Artículo en Inglés | MEDLINE | ID: mdl-25321224

RESUMEN

A self-contained electro-optical module for scanning extreme ultraviolet (EUV) reflection microscopy at 13.5 nm wavelength has been developed. The system has been designed to work with stand-alone commercially available EUV high harmonic generation (HHG) sources through the implementation of narrowband harmonic selecting multilayers and off-axis elliptical short focal length zoneplates. The module has been successfully integrated into an EUV mask scanning microscope achieving diffraction limited imaging performance (84 nm point spread function).

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA