Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 165
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Arch Orthop Trauma Surg ; 144(4): 1603-1609, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38441618

RESUMEN

INTRODUCTION: Distal radioulnar joint (DRUJ) instabilities are challenging and their optimal treatment is controversial. In special cases or when reconstruction of the stabilizing triangular fibrocartilage complex (TFCC) fails, K-wire transfixation can be performed. However, no consensus has been reached regarding the rotational position of the forearm in which this should be done. Therefore, it was investigated whether anatomical reduction would best be achieved by transfixation in neutral position or supination of the forearm. MATERIALS AND METHODS: Twelve cadaveric upper limbs were examined before dissection of the DRUJ stabilizing ligaments and after closed transfixation in both positions by C-arm cone-beam CT. Whether this was first done in neutral position or in supination was randomized. The change in the radioulnar ratio (RR) in percentage points (%points) was analyzed using Student's t-test. RR was used since it is a common and sensitive method to evaluate DRUJ reduction, expressing the ulnar head's position in the sigmoid notch as a length ratio. RESULTS: The analysis showed an increased change in RR in neutral position with 5.4 ± 9.7%points compared to fixation in supination with 0.2 ± 16.1%points, yet this was not statistically significant (p = 0.404). CONCLUSIONS: Neither position leads to a superior reduction in general. However, the result was slightly closer to the anatomical position in supination. Thus, transfixation of the DRUJ should be performed in the position in which reduction could best be achieved and based on these data, that tends to be in supination. Further studies are necessary to validate these findings and to identify influential factors.


Asunto(s)
Antebrazo , Inestabilidad de la Articulación , Humanos , Supinación , Pronación , Fenómenos Biomecánicos , Articulación de la Muñeca/cirugía , Cadáver , Inestabilidad de la Articulación/cirugía
2.
BMC Geriatr ; 23(1): 748, 2023 11 15.
Artículo en Inglés | MEDLINE | ID: mdl-37968595

RESUMEN

BACKGROUND: Different treatment options are discussed for geriatric odontoid fracture. The aim of this study was to compare the treatment options for geriatric odontoid fractures. METHODS: Included were patients with the following criteria: age ≥ 65 years, identification of seniors at risk (ISAR score ≥ 2), and odontoid fracture type A/B according to Eysel and Roosen. Three groups were compared: conservative treatment, surgical therapy with ventral screw osteosynthesis or dorsal instrumentation. At a follow-up examination, the range of motion and the trabecular bone fracture healing rate were evaluated. Furthermore, demographic patient data, neurological status, length of stay at the hospital and at the intensive care unit (ICU) as well as the duration of surgery and occurring complications were analyzed. RESULTS: A total of 72 patients were included and 43 patients could be re-examined (range: 2.7 ± 2.1 months). Patients with dorsal instrumentation had a better rotation. Other directions of motion were not significantly different. The trabecular bone fracture healing rate was 78.6%. The patients with dorsal instrumentation were hospitalized significantly longer; however, their duration at the ICU was shortest. There was no significant difference in complications. CONCLUSION: Geriatric patients with odontoid fracture require individual treatment planning. Dorsal instrumentation may offer some advantages.


Asunto(s)
Fracturas Óseas , Apófisis Odontoides , Fracturas de la Columna Vertebral , Humanos , Anciano , Fracturas de la Columna Vertebral/diagnóstico por imagen , Fracturas de la Columna Vertebral/cirugía , Tratamiento Conservador/efectos adversos , Apófisis Odontoides/diagnóstico por imagen , Apófisis Odontoides/cirugía , Apófisis Odontoides/lesiones , Fijación Interna de Fracturas/efectos adversos , Resultado del Tratamiento
3.
BMC Musculoskelet Disord ; 24(1): 850, 2023 Oct 27.
Artículo en Inglés | MEDLINE | ID: mdl-37891527

RESUMEN

BACKGROUND: Surgical treatment of distal clavicle fractures Neer type II is challenging. A gold standard has not yet been established, thus various surgical procedures have been described. The purpose of this study is to report the radiological and clinical outcomes using hook plate fixation in Neer type II distal clavicle fractures. METHODS: We retrospectively reviewed data of 53 patients who underwent hook plate fixation between December 2009 and December 2019 with ≥ 2 years of follow-up. Patients with preexisting pathologies or concomitant injuries of the ipsilateral shoulder were excluded. Pre- and postoperative coracoclavicular distance (CCD), bony union and patient-reported outcomes were collected, including the Constant Score (CS) and Subjective Shoulder Value (SSV). Complications and revisions were recorded. RESULTS: At a mean final follow-up of 6.2 years, mean SSV was 91.0% (range, 20-100) and mean CS was 80.9 points (range, 25-99). The mean preoperative CCD was 19.0 mm (range, 5.7-31.8), the mean postoperative CCD was 8.2 mm (range, 4.4-12.2) and the mean CCD following hardware removal was 9.7 mm (range, 4.7-18.8). The loss of reduction following hardware removal was statistically significant (P = 0.007). Eleven (20.8%) patients had complications, with 5 cases of deep or superficial infection (9.4%), four non-unions (7.5%), one periosteosynthetic fracture, one postoperative seroma, one implant failure and one symptomatic acromioclavicular joint arthritis (all 1.9%). A total of 10 patients (18.9%) underwent revision surgery at a mean of 113 (range, 7-631) days. CONCLUSION: Medium-term patient-reported outcomes for hook plate fixation of Neer type II distal clavicle fractures are satisfactory; however, one in five patients suffers a complication with the majority of them requiring revision surgery.


Asunto(s)
Fijación Interna de Fracturas , Fracturas Óseas , Humanos , Fijación Interna de Fracturas/efectos adversos , Fijación Interna de Fracturas/métodos , Clavícula/diagnóstico por imagen , Clavícula/cirugía , Clavícula/lesiones , Estudios Retrospectivos , Resultado del Tratamiento , Fracturas Óseas/diagnóstico por imagen , Fracturas Óseas/cirugía , Fracturas Óseas/etiología , Placas Óseas/efectos adversos
4.
BMC Musculoskelet Disord ; 24(1): 752, 2023 Sep 23.
Artículo en Inglés | MEDLINE | ID: mdl-37742007

RESUMEN

BACKGROUND: Studies have shown that pedicle screw placement using navigation can potentially reduce radiation exposure of surgical personnel compared to conventional methods. Spinal navigation is based on an interaction of a navigation software and 3D imaging. The 3D image data can be acquired using different imaging modalities such as iCT and CBCT. These imaging modalities vary regarding acquisition technique and field of view. The current literature varies greatly in study design, in form of dose registration, as well as navigation systems and imaging modalities analyzed. Therefore, the aim of this study was a standardized comparison of three navigation and imaging system combinations in an experimental setting in an artificial spine model. METHODS: In this experimental study dorsal instrumentation of the thoracolumbar spine was performed using three imaging/navigation system combinations. The system combinations applied were the iCT/Curve, cCBCT/Pulse and oCBCT/StealthStation. Referencing scans were obtained with each imaging modality and served as basis for the respective navigation system. In each group 10 artificial spine models received bilateral dorsal instrumentation from T11-S1. 2 referencing and control scans were acquired with the CBCTs, since their field of view could only depict up to five vertebrae in one scan. The field of view of the iCT enabled the depiction of T11-S1 in one scan. After instrumentation the region of interest was scanned again for evaluation of the screw position, therefore only one referencing and one control scan were obtained. Two dose meters were installed in a spine bed ventral of L1 and S1. The dose measurements in each location and in total were analyzed for each system combination. Time demand regarding screw placement was also assessed for all system combinations. RESULTS: The mean radiation dose in the iCT group measured 1,6 ± 1,1 mGy. In the cCBCT group the mean was 3,6 ± 0,3 mGy and in the oCBCT group 10,3 ± 5,7 mGy were measured. The analysis of variance (ANOVA) showed a significant (p < 0.0001) difference between the three groups. The multiple comparisions by the Kruskall-Wallis test showed no significant difference for the comparison of iCT and cCBCT (p1 = 0,13). Significant differences were found for the direct comparison of iCT and oCBCT (p2 < 0,0001), as well as cCBCT and oCBCT (p3 = 0,02). Statistical analysis showed that significantly (iCT vs. oCBCT p = 0,0434; cCBCT vs. oCBCT p = 0,0083) less time was needed for oCBCT based navigated pedicle screw placement compared to the other system combinations (iCT vs. cCBCT p = 0,871). CONCLUSION: Under standardized conditions oCBCT navigation demanded twice as much radiation as the cCBCT for the same number of scans, while the radiation exposure measured for the iCT and cCBCT for one scan was comparable. Yet, time effort was significantly less for oCBCT based navigation. However, for transferability into clinical practice additional studies should follow evaluating parameters regarding feasibility and clinical outcome under standardized conditions.


Asunto(s)
Tornillos Pediculares , Exposición a la Radiación , Humanos , Diagnóstico por Imagen , Exposición a la Radiación/prevención & control , Análisis de Varianza , Frecuencia Cardíaca
5.
Knee Surg Sports Traumatol Arthrosc ; 31(7): 2870-2876, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36454291

RESUMEN

PURPOSE: Patellar maltracking caused by a rupture of the medial patellofemoral ligament (MPFL) can be improved by MPFL reconstruction (MPFL-R) with a tendon graft. Nonresorbable suture tape (FiberTape®, FT) is possibly becoming an option to tendon grafts for MPFL-R. Patella-side fixation of FT can be performed with suture anchors or via soft-tissue fixation. The aim of this study was to investigate patellar tracking considering soft-tissue-based and anchor-based patella-side fixation techniques. METHODS: In eight fresh-frozen human knee joint specimens (m/f 4/4; age 75 ± 10 years), the MPFL was identified, and a rupture was placed near the femoral insertion site. In the study group (SG; 4 knees), soft-tissue fixation of the FT was performed at the medial patellar retinaculum; in the control group (CG; 4 knees), FT was fixed at the patella via suture anchors. For native MPFL (nMPFL), ruptured ("injured") MPFL (iMPFL) and reconstructed MPFL (FT-MPFL-SG, respectively, FT-MPFL-CG) cone beam CT scans were performed in 15°, 30°, and 45° of knee joint flexion. Patellar tracking was assessed using the radiological parameters patellar tilt (PT), congruence angle (CA) and posterior patellar edge-trochlear groove ratio (PTR). RESULTS: All recorded radiological parameters increased, respectively, decreased in the CG and SG from the nMPFL to the iMPFL state. After MPFL-R, all parameters normalized when compared to the intact state (nMPFL), regardless of patella-side fixation technique. All investigated parameters of patellotrochlear alignment were positively, respectively, negatively significantly (p < 0.05) correlated throughout all evaluated conditions (nMPFL, iMPFL, FT-MPFL-SG, FT-MPFL-CG). CONCLUSION: MPFL-R with a nonresorbable suture tape can normalize patellar maltracking in fresh-frozen human knee joint specimens in earlier degrees of knee joint flexion independent of patella-side fixation technique. The investigated parameters of patellotrochlear alignment correlate with each other.


Asunto(s)
Luxación de la Rótula , Articulación Patelofemoral , Humanos , Anciano , Anciano de 80 o más Años , Rótula/cirugía , Articulación Patelofemoral/cirugía , Cadáver , Articulación de la Rodilla/cirugía , Ligamentos Articulares/cirugía , Suturas , Luxación de la Rótula/cirugía
6.
Knee Surg Sports Traumatol Arthrosc ; 31(1): 292-298, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-35994076

RESUMEN

PURPOSE: Reconstruction of the medial patellofemoral ligament (MPFL-R) with nonresorbable suture tape (FiberTape®, FT) is becoming popular. Patella-side fixation of the FT can be performed with suture anchors or via soft-tissue fixation. The aim of this study was to investigate whether patella-side soft-tissue fixation can achieve equivalent primary stability compared to suture-anchor fixation. METHODS: In ten human, fresh-frozen knee joint specimens (m/f 6/4; age 74 ± 9 a), the MPFL was identified and dissected near the femoral insertion site. In five knee joints, the MPFL-R using FT was performed with soft-tissue fixation at the patella (study group; SG), and in five knee joints, the FT was fixed via suture anchors (control group, CG). All reconstructions were evaluated until load to failure of the patella-side fixation with a displacement rate of 200 mm/min. RESULTS: The mean maximum load to failure in the SG was 395.3 ± 57.9 N. All reconstructions failed by complete tearing off the medial patellar retinaculum from its medial patellar margin, but fixation of the FT remained stable. In the CG, the mean maximum load to failure was 239.4 ± 54.5 N and was significantly different compared to the SG (p = 0.04). All reconstructions failed via pullout of the suture anchors. Stiffness and elongation did not differ between the groups, and no failure of the FT was observed in any of the specimens. CONCLUSION: Primary stability of soft-tissue MPFL-R using FT was superior to suture-anchor fixation. Both fixation techniques provided sufficient primary stability, superior to previously reported native MPFL tensile strengths. MPFL-R with FT could be a possible alternative procedure for MPFL-R, eliminating potential complications due to autologous tendon graft harvesting.


Asunto(s)
Articulación Patelofemoral , Anclas para Sutura , Humanos , Anciano , Anciano de 80 o más Años , Articulación Patelofemoral/cirugía , Fijación del Tejido , Rótula/cirugía , Articulación de la Rodilla , Ligamentos Articulares/cirugía , Suturas
7.
Arch Orthop Trauma Surg ; 143(2): 707-715, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34432098

RESUMEN

PURPOSE: Infection represents probably the most challenging complication in shoulder arthroplasty and all other surgical procedures of the shoulder. A deep infection of the shoulder is often combined with a destruction of the joint and a loss of function. In many cases the arthroplasty is the last resort for these patients to obtain a satisfactory function. The objective of this study was to determine outcome data on microbiota and clinical results of a two-stage shoulder arthroplasty procedure after deep infection of the shoulder. METHODS: Twenty-six patients with a deep shoulder infection after arthroplasty, osteosynthesis, or rotator-cuff repair were included, while two patients had an empyema without prior surgery. All underwent initial surgical debridement with implantation of an antibiotic-loaded spacer, followed by postoperative systemic antibiotics. The patients obtained definitive shoulder arthroplasty in a second surgery. None of the patients had to undergo more than two surgeries before the arthroplasty. The follow-up analysis including microbiota results, complication rates, and functional outcomes could be determined after at least 1 year in 60% of patients (n = 16). RESULTS: The most frequently detected microorganisms were S. epidermidis (31%, n = 10) and Cutibacterium acnes (19%, n = 6). In 28% (n = 9) of cases multi-drug resistant bacteria were detected and in 35% (n = 8) of cases more than one microorganism was found. The overall revision rate was 42%, 11 of 26 patients, in the first 8 weeks after arthroplasty. Reasons for revision were joint dislocations in 23% (n = 6), 15% (n = 4) postoperative hematomas, one (4%) re-infection and one (4%) periprosthetic fracture. At follow-up after 19.3 ± 5.5 months postoperatively, a mean abduction of 113.4°, anteversion of 122.8° and external rotation of 14° was found, with an average age and gender-adjusted Constant Score of the affected shoulder of 63. The subjects' pain and impairment in normal life measured by a questionnaire with school grades were significantly reduced (p < 0.05) as compared to prior shoulder arthroplasty. CONCLUSION: The most relevant bacteria in the study cohort were Staphylococcus subspecies and to a lower extent Cutibacterium acnes. A high number of multi-drug resistant and mixed microbiota spectra were detected, defining a need to adapt therapeutic regimen targeting these microbiotas. The two-stage shoulder arthroplasty after a deep infection resulted in excellent infection control with however high early postoperative rates for joint dislocation (23%) and hematomas (15%). At follow-up a stable joint was achieved with a sufficient functional outcome and satisfying outcome for activities of daily living and pain. CLINICAL TRIAL: Trial registration number: DRKS00016927, date of registration: 2019/03/19.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Articulación del Hombro , Humanos , Actividades Cotidianas , Antibacterianos/uso terapéutico , Artroplastia , Artroplastía de Reemplazo de Hombro/efectos adversos , Estudios de Seguimiento , Dolor/etiología , Rango del Movimiento Articular , Reoperación/métodos , Estudios Retrospectivos , Articulación del Hombro/cirugía , Resultado del Tratamiento
8.
Rehabilitation (Stuttg) ; 62(5): 308-318, 2023 Oct.
Artículo en Alemán | MEDLINE | ID: mdl-37848041

RESUMEN

Changes in the employment market and improvements in the current prosthetic treatment have encouraged German Statutory Health Insurance e. V. (DGUV) to re-examine the standard values for reduced earning capacity after work related accidents. The new standard values for reduced earning capacity came into force on 01.11.2019. The present article summarises the consensus paper of the group of independent experts.


Asunto(s)
Seguro por Accidentes , Programas Nacionales de Salud , Humanos , Alemania , Renta , Empleo
9.
BMC Med Imaging ; 22(1): 181, 2022 10 19.
Artículo en Inglés | MEDLINE | ID: mdl-36261814

RESUMEN

BACKGROUND: In syndesmotic injuries, incorrect reduction leads to early arthrosis of the ankle joint. Being able to analyze the reduction result is therefore crucial for obtaining an anatomical reduction. Several studies that assess fibular rotation in the incisura have already been published. The aim of the study was to validate measurement methods that use cone beam computed tomography imaging to detect rotational malpositions of the fibula in a standardized specimen model. METHODS: An artificial Maisonneuve injury was created on 16 pairs of fresh-frozen lower legs. Using a stable instrument, rotational malpositions of 5, 10, and 15° internal and external rotation were generated. For each malposition of the fibula, a cone beam computed tomography scan was performed. Subsequently, the malpositions were measured and statistically evaluated with t-tests using two measuring methods: angle (γ) at 10 mm proximal to the tibial joint line and the angle (δ) at 6 mm distal to the talar joint line. RESULTS: Rotational malpositions of ≥ 10° could be reliably displayed in the 3D images using the measuring method with angle δ. For angle γ significant results could only be displayed for an external rotation malposition of 15°. CONCLUSIONS: Clinically relevant rotational malpositions of the fibula in comparison with an uninjured contralateral side can be reliably detected using intraoperative 3D imaging with a C-arm cone beam computed tomography. This may allow surgeons to achieve better reduction of fibular malpositions in the incisura tibiofibularis.


Asunto(s)
Traumatismos del Tobillo , Peroné , Humanos , Peroné/diagnóstico por imagen , Peroné/lesiones , Traumatismos del Tobillo/diagnóstico por imagen , Articulación del Tobillo/diagnóstico por imagen , Tibia , Tomografía Computarizada de Haz Cónico
10.
Pediatr Emerg Care ; 38(1): e75-e84, 2022 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-32604393

RESUMEN

OBJECTIVES: The purpose of this study was to (i) develop a protocol that supports decision making for prehospital spinal immobilization in pediatric trauma patients based on evidence from current scientific literature and (ii) perform an applicability test on emergency medicine personnel. METHODS: A structured search of the literature published between 1980 and 2019 was performed in MEDLINE using PubMed. Based on this literature search, a new Emergency Medicine Spinal Immobilization Protocol for pediatric trauma patients (E.M.S. IMMO Protocol Pediatric) was developed. Parameters found in the literature, such as trauma mechanism and clinical findings that accounted for a high probability of spinal injury, were included in the protocol. An applicability test was administered to German emergency medicine personnel using a questionnaire with case examples to assess correct decision making according to the protocol. RESULTS: The E.M.S. IMMO Protocol Pediatric was developed based on evidence from published literature. In the applicability test involving 44 emergency medicine providers revealed that 82.9% of participants chose the correct type of immobilization based on the protocol. A total of 97.8% evaluated the E.M.S. IMMO Protocol Pediatric as helpful. CONCLUSIONS: Based on the current literature, the E.M.S. IMMO Protocol Pediatric was developed in accordance with established procedures used in trauma care. The decision regarding immobilization is made on based on the cardiopulmonary status of the patient, and life-threatening injuries are treated with priority. If the patient presents in stable condition, the necessity for full immobilization is assessed based upon the mechanisms of injury, assessment of impairment, and clinical examination.


Asunto(s)
Servicios Médicos de Urgencia , Medicina de Emergencia , Traumatismos Vertebrales , Niño , Humanos , Inmovilización , Traumatismos Vertebrales/diagnóstico , Traumatismos Vertebrales/terapia , Encuestas y Cuestionarios
11.
J Digit Imaging ; 35(3): 514-523, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35146612

RESUMEN

Previous studies have demonstrated a frequent occurrence of screw/K-wire malpositioning during surgical fracture treatment under 2D fluoroscopy and a correspondingly high revision rate as a result of using intraoperative 3D imaging. In order to facilitate and accelerate the diagnosis of implant malpositioning in 3D data sets, this study investigates two versions of an implant detection software for mobile 3D C-arms in terms of their detection performance based on comparison with manual evaluation. The 3D data sets of patients who had received surgical fracture treatment at five anatomical regions were extracted from the research database. First, manual evaluation of the data sets was performed, and the number of implanted implants was assessed. For 25 data sets, the time required by four investigators to adjust each implant was monitored. Subsequently, the evaluation was performed using both software versions based on the following detection parameters: true-positive-rate, false-negative-rate, false-detection-rate and positive predictive value. Furthermore, the causes of false positive and false negative detected implants depending on the anatomical region were investigated. Two hundred fourteen data sets with overall 1767 implants were included. The detection parameters were significantly improved (p<.001) from version 1 to version 2 of the implant detection software. Automatic evaluation required an average of 4.1±0.4 s while manual evaluation was completed in 136.15±72.9 s (p<.001), with a statistically significant difference between experienced and inexperienced users (p=.005). In summary, version 2 of the implant detection software achieved significantly better results. The time saved by using the software could contribute to optimizing the intraoperative workflow.


Asunto(s)
Imagenología Tridimensional , Programas Informáticos , Fluoroscopía/métodos , Humanos , Imagenología Tridimensional/métodos
12.
J Shoulder Elbow Surg ; 30(7): e361-e369, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33484832

RESUMEN

BACKGROUND: The purposes of this study were (1) to report functional outcomes; (2) to assess complications, revisions, and survival rate; and (3) to assess differences in functional outcomes between removed and retained radial head arthroplasties (RHAs), early and delayed treatment, and type of RHA used at long-term follow-up after monopolar RHA for unreconstructible radial head fractures or their sequelae. METHODS: Seventy-eight patients (mean age, 59.2 years) who were at least 6 years postoperatively after monopolar RHA for unreconstructible RHFs or their sequelae were included. The Mayo Elbow Performance Score (MEPS); Quick Disability of the Arm, Shoulder, and Hand (QuickDASH) score; visual analog scale; postoperative satisfaction (1-6, 6 = highly unsatisfied); range of motion; complications; and revisions were assessed. Radiographic findings were reported. Kaplan-Meier survival analysis was performed. Subgroups (RHA type, early vs. delayed surgery, RHA removed vs. retained) were compared. RESULTS: At a median clinical follow-up of 9.5 years (range: 6.0-28.4 years), median MEPS was 80.0 (interquartile range [IQR]: 60.0-97.5), median QuickDASH was 22.0 (IQR: 4.6-42.6), median visual analog scale was 1 (IQR: 0-4), median postoperative satisfaction was 2 (IQR: 1-3), and median arc of extension/flexion was 110° (IQR: 80°-130°). Radiographic follow-up was available for 48 patients at a median of 7.0 years (range: 2.0-15.0 years). Heterotopic ossifications were seen in 14 (29.2%), moderate-to-severe capitellar osteopenia/abrasion in 3 (6.1%), moderate-to-severe ulnohumeral degeneration in 3 (6.1%), and periprosthetic radiolucencies in 17 (35.4%) patients. Twenty-nine patients (37.2%) had complications and 20 patients (25.6%) underwent RHA exchange or removal. Kaplan-Meier analysis with failure defined as RHA exchange or removal demonstrated survival of 75.1% (95% confidence interval: 63.7-83.3) at 18 years. The highest annual failure rate was observed in the first year in which the RHAs of 7 patients (9%) were exchanged or removed. No significant differences were detected between type of RHA in MEPS (Mathys: 82.5 [75.0-100] vs. Evolve: 80.0 [60.0-95.0]; P = .341) and QuickDASH (Mathys: 12.5 [0-34.4] vs. Evolve: 26.7 [6.9-46.2]; P = .112). Early surgery (≤3 weeks) yielded significantly superior MEPS (80.0 [70.0-100.0] vs. 52.5 [30.0-83.8]; P = .014) and QuickDASH (18.6 [1.5-32.6] vs. 46.2 [31.5-75.6]; P = .002) compared with delayed surgery (>3 weeks). Patients with retained RHAs had significantly better MEPS (80.0 [67.5-100] vs. 70.0 [32.5-82.5]; P = .016) and QuickDASH (18.1 [1.7-31.9] vs. 49.1 [22.1-73.8]; P = .007) compared with patients with removed RHAs. CONCLUSIONS: Long-term outcomes for RHA are satisfactory; however, there is a high complication and revision rate, resulting in implant survival of 75.1% at 18 years with the highest annual failure rate observed in the first postoperative year.


Asunto(s)
Articulación del Codo , Fracturas del Radio , Articulación del Codo/diagnóstico por imagen , Articulación del Codo/cirugía , Humanos , Persona de Mediana Edad , Fracturas del Radio/diagnóstico por imagen , Fracturas del Radio/cirugía , Rango del Movimiento Articular , Estudios Retrospectivos , Tasa de Supervivencia , Resultado del Tratamiento
13.
J Digit Imaging ; 34(4): 788-797, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-34327626

RESUMEN

In clinical routine, wound documentation is one of the most important contributing factors to treating patients with acute or chronic wounds. The wound documentation process is currently very time-consuming, often examiner-dependent, and therefore imprecise. This study aimed to validate a software-based method for automated segmentation and measurement of wounds on photographic images using the Mask R-CNN (Region-based Convolutional Neural Network). During the validation, five medical experts manually segmented an independent dataset with 35 wound photographs at two different points in time with an interval of 1 month. Simultaneously, the dataset was automatically segmented using the Mask R-CNN. Afterwards, the segmentation results were compared, and intra- and inter-rater analyses performed. In the statistical evaluation, an analysis of variance (ANOVA) was carried out and dice coefficients were calculated. The ANOVA showed no statistically significant differences throughout all raters and the network in the first segmentation round (F = 1.424 and p > 0.228) and the second segmentation round (F = 0.9969 and p > 0.411). The repeated measure analysis demonstrated no statistically significant differences in the segmentation quality of the medical experts over time (F = 6.05 and p > 0.09). However, a certain intra-rater variability was apparent, whereas the Mask R-CNN consistently provided identical segmentations regardless of the point in time. Using the software-based method for segmentation and measurement of wounds on photographs can accelerate the documentation process and improve the consistency of measured values while maintaining quality and precision.


Asunto(s)
Redes Neurales de la Computación , Programas Informáticos , Humanos , Procesamiento de Imagen Asistido por Computador
14.
Arch Orthop Trauma Surg ; 141(10): 1649-1657, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32780199

RESUMEN

INTRODUCTION: The aim of the present study was to analyze the injury pattern and thus the dislocation mechanism after simple elbow dislocation using radiographs and magnetic resonance imaging (MRI) data sets. MATERIALS AND METHODS: The MRI data sets of 64 patients with a mean age of 44 years (18-77 years) were analyzed retrospectively. The inclusion criteria for the study were (1) radiograph with confirmed simple elbow dislocation, (2) low-energy trauma, (3) MRI of the affected elbow ≤ 3 weeks after trauma. The dislocation direction was determined using radiographs. The integrity of the lateral collateral ligament complex (LCLC), common extensor origin (CEO), anterior capsule (AC), medial collateral ligament (MCL), and common flexor origin (CFO) as well as the joint congruity were assessed based on MRI. RESULTS: 34 patients (53%) had a posterolateral, 26 patients (41%) a posterior, and 4 patients (6%) a posteromedial dislocation. LCLC and AC were affected in 64 out of 64 patients (100%). MCL was affected in 58 patients (91%). CEO were affected in 25 patients (39%) and the CFO in 20 patients (31%). In 11 patients (17%) the injury pattern was more pronounced medially than laterally (MCL, CFO, LCLC), with 2 of these patients exhibiting only a partial LCLC tear. All cases with joint incongruency (n = 12, 19%) showed CEO and/or CFO involvement. CONCLUSIONS: Simple elbow dislocation leads to a very heterogeneous spectrum of soft tissue injury pattern. A small proportion of patients showed medially pronounced injury patterns. These findings strongly indicate existence of a "reversed Horii circle" with an underlying valgus mechanism (medial force induction) originating and continuing from medial to anterior.


Asunto(s)
Ligamentos Colaterales , Articulación del Codo , Inestabilidad de la Articulación , Adulto , Codo , Articulación del Codo/diagnóstico por imagen , Humanos , Estudios Retrospectivos
15.
Anaesthesist ; 70(11): 922-927, 2021 11.
Artículo en Alemán | MEDLINE | ID: mdl-33909105

RESUMEN

BACKGROUND: Immobilization of the cervical spine is a standard procedure in emergency medicine mostly achieved via a cervical collar. In the emergency room other forms of immobilization are utilized as cervical collars have certain drawbacks. The present study aimed to provide preliminary data on the efficiency of immobilization in the emergency room by analyzing the residual spinal motion of the patient's head on different kinds of head rests. METHODS: In the present study biomechanical motion data of the cervical spine of a test subject were analyzed. The test subject was placed in a supine position on a mobile stretcher (Stryker M1 Roll-In System, Kalamazoo, MI, USA) wearing a cervical collar (Perfit ACE, Ballerup, Denmark). Three different head rests were tested: standard pillow, concave pillow and cavity pillow. The test subject carried out a predetermined motion protocol: right side inclination, left side inclination, flexion and extension. The residual spinal motion was recorded with wireless motion trackers (inertial measurement unit, Xsens Technologies, Enschede, The Netherlands). The first measurement was performed without a cervical collar or positioning on the pillows to measure the physiological baseline motion. Subsequently, three measurements were taken with the cervical collar applied and the pillows in place. From these measurements, a motion score was calculated that can represent the motion of the cervical spine. RESULTS: When the test subject's head was positioned on a standard pillow the physiological motion score was reduced from 69 to 40. When the test subject's head was placed on concave pillow the motion score was further reduced from 69 to 35. When the test subject's head was placed on cavity pillow the motion score was reduced from 69 to 59. The observed differences in the overall motion score of the cervical spine are mainly due to reduced flexion and extension rather than rotation or lateral inclination. CONCLUSION: The motion score of the cervical spine using motion sensors can provide important information for future analyses. The results of the present study suggest that trauma patients can be immobilized in the early trauma phase with a cervical collar and a head rest. The application of a cervical collar and the positioning on the concave pillow may achieve a good immobilization of the cervical spine in trauma patients in the early trauma phase.


Asunto(s)
Vértebras Cervicales , Inmovilización , Servicio de Urgencia en Hospital , Humanos , Rango del Movimiento Articular , Rotación
16.
Arthroscopy ; 36(1): 178-185, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31864574

RESUMEN

PURPOSE: To compare and evaluate knee laxity and functional outcomes between autologous bone graft and silicate-substituted calcium phosphate (Si-CaP) in the treatment of tunnel defects in 2-stage revision anterior cruciate ligament reconstruction (ACLR). METHODS: This prospective, randomized controlled trial was conducted between 2012 and 2015 with a total of 40 patients who underwent 2-stage revision ACLR. The tunnels were filled with autologous iliac crest cancellous bone graft in 20 patients (control group) and with Si-CaP in the other 20 patients (intervention group). After a minimum follow-up period of 2 years, functional outcomes were assessed by KT-1000 arthrometry (side-to-side [STS] difference), the Tegner score, the Lysholm score, and the International Knee Documentation Committee score. RESULTS: A total of 37 patients (follow-up rate, 92.5%) with an average age of 31 years were followed up for 3.4 years (range, 2.2-5.5 years). The KT-1000 measurement did not show any STS difference between the bone graft group (0.9 ± 1.5 mm) and the Si-CaP group (0.7 ± 2.0 mm) (P = .731). One patient in the intervention group (5%) had an STS difference greater than 5 mm. Both groups showed significant improvements in the Tegner score, Lysholm score, and International Knee Documentation Committee score from preoperative assessment to final follow-up (P ≤ .002), without any difference between the 2 groups (P ≥ .396). Complications requiring revision occurred in 4 control patients (22%) and in 2 patients in the intervention group (11%) (P = .660). No complications in relation to Si-CaP were observed. CONCLUSIONS: Equivalent knee laxity and clinical function outcomes were noted 3 years after surgery in both groups of patients. Si-CaP bone substitute is therefore a safe alternative to autologous bone graft for 2-stage ACLR. LEVEL OF EVIDENCE: Level I, prospective, randomized controlled clinical trial.


Asunto(s)
Lesiones del Ligamento Cruzado Anterior/cirugía , Reconstrucción del Ligamento Cruzado Anterior/métodos , Trasplante Óseo/métodos , Compuestos de Calcio/farmacología , Inestabilidad de la Articulación/cirugía , Articulación de la Rodilla/cirugía , Rango del Movimiento Articular/fisiología , Silicatos/farmacología , Adulto , Lesiones del Ligamento Cruzado Anterior/complicaciones , Lesiones del Ligamento Cruzado Anterior/diagnóstico , Lesiones del Ligamento Cruzado Anterior/fisiopatología , Autoinjertos , Sustitutos de Huesos , Femenino , Estudios de Seguimiento , Humanos , Inestabilidad de la Articulación/diagnóstico , Inestabilidad de la Articulación/etiología , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/fisiopatología , Masculino , Estudios Prospectivos , Radiografía , Reoperación , Factores de Tiempo , Resultado del Tratamiento
17.
J Digit Imaging ; 33(5): 1136-1143, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32632648

RESUMEN

The aim of our study was to evaluate whether software-based artifact reduction can achieve an improved image quality, using intraoperative 3D imaging in spinal surgery. A total of 49 intraoperative 3D image datasets of patients, who underwent surgery with pedicle screw placement, were retrospectively evaluated. The visibility of anatomical structures and the diameter of the pedicle screws were examined, with and without the application of the artifact reduction software. All software prototypes can improve the visibility of anatomical structures (P < 0.01), except MAR (metal artifact reduction) combined with IRIS (iterative reconstruction in image space) (P = 0.04). The algorithms MAR and MAR-2 can reduce the blooming artifacts significantly (P < 0.01), but SL (Shepp & Logan) cannot (P = 0.08-0.988). In summary, software-based artifact reduction for intraoperative 3D datasets can improve the current image quality. Additional information regarding the implant placement and the fracture reduction is therefore generated for the surgeon.


Asunto(s)
Artefactos , Imagenología Tridimensional , Algoritmos , Tomografía Computarizada de Haz Cónico , Humanos , Estudios Retrospectivos , Programas Informáticos
18.
Int Orthop ; 44(7): 1239-1253, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32451654

RESUMEN

OBJECTIVE: The diagnosis of instability of the injured upper cervical spine remains controversial, due to its complicated anatomical configuration and biomechanical property. Since identifying unstable injuries of the upper cervical spine is essential for immediate stabilizing therapy, this article reviews the current classification systems of upper cervical spine injuries and their statements towards instability. METHODS: A systematic review of literature concerning upper cervical spine injuries was performed on the PubMed database from inception to December 2019. An English literature search was conducted using various combinations of keyword terms. RESULTS: Numerous separate classification systems for each specific injury of the upper cervical spine were obtained. The early classifications are based primarily on injury morphology and mechanism. The recent classifications pay more attention to the investigation of ligamentous status. Various instability criteria were established as well. The determinants involve translation, vertical distraction, angulation, rotation, obliquity of fracture line, comminution, and ligamentous disruption. The status of crucial ligaments plays a key role in determining instability of upper cervical spine injuries. CT scan is more sensitive and reliable than X-ray in detecting misalignment of the upper cervical spine. CONCLUSION: Only a few classification systems support decision-making concerning instability leading to early operative treatment. The ligamentous integrity is the key element of impacting the stability of the upper cervical spine injuries. The transverse ligament serves as the most crucial element in determining the stability of occipital condyle fractures and atlas fractures as well as atlanto-axial injury. The integrity of anterior longitudinal ligament, disc, and facet joint attributes to the stability of axis fractures. The integrity of tectorial membrane and alar ligaments determines the stability of atlanto-occipital dislocation. The development of a newly classification system concerning ligamentous instability with a high clinical and scientific impact is recommended.


Asunto(s)
Fracturas Óseas , Luxaciones Articulares , Traumatismos Vertebrales , Vértebras Cervicales/diagnóstico por imagen , Vértebras Cervicales/lesiones , Humanos , Ligamentos Articulares/diagnóstico por imagen , Traumatismos Vertebrales/diagnóstico
19.
Unfallchirurg ; 123(5): 413-418, 2020 May.
Artículo en Alemán | MEDLINE | ID: mdl-32060596

RESUMEN

A 50-year-old male suffered a crash landing while paragliding and sustained a posterior dislocation of the hip with a Pipkin fracture type 4 (fracture of the posterior acetabular wall and Pipkin fracture type 2) and a lesion of the sciatic nerve. After primary treatment in an external hospital, the patient was transferred to this hospital 4 days following the trauma. An operative stabilization of the acetabular fracture and the Pipkin fracture was performed using a trochanter flip osteotomy. Despite a large central defect of the femoral head it was decided to attempt a reconstruction. Following fixation of the Pipkin fragment an autologous bone graft harvested from the intertrochanteric region was used to fill the defect. Subsequently, a collagen matrix was applied onto the filled defect and a perineural adaptation of the sciatic nerve was performed.


Asunto(s)
Luxación de la Cadera , Fracturas de Cadera , Acetábulo , Cabeza Femoral , Fijación Interna de Fracturas , Humanos , Masculino , Persona de Mediana Edad , Nervio Ciático , Resultado del Tratamiento
20.
Unfallchirurg ; 123(4): 289-301, 2020 Apr.
Artículo en Alemán | MEDLINE | ID: mdl-31768566

RESUMEN

BACKGROUND: To protect the spine from secondary damage, spinal immobilization is a standard procedure in prehospital trauma management. Immobilization protocols aim to support emergency medicine personnel in quick decision making but predominantly focus on the adult spine; however, trauma mechanisms and injury patterns in adults differ from those in children and applying adult prehospital immobilization protocols to pediatric patients may be insufficient. Adequate protocols for children with spinal injuries are currently unavailable. OBJECTIVE: The aim of this study was (i) to develop a protocol that supports decision making for prehospital spinal immobilization in pediatric trauma patients based on evidence from current scientific literature and (ii) to perform a first analysis of the quality of results if the protocol is used by emergency personnel. MATERIAL AND METHODS: Based on a structured literature search a new immobilization protocol was developed. Analysis of the quality of results was performed by a questionnaire containing four case scenarios in order to assess correct decision making. The decision about spinal immobilization was made without and with the utilization of the protocol. RESULTS: The E.M.S. IMMO Protocol Pediatric was developed based on the literature. The analysis of the quality of results was performed involving 39 emergency medicine providers. It could be shown that if the E.M.S. IMMO Protocol Pediatric was used, the correct type of immobilization was chosen more frequently. A total of 38 out of 39 participants evaluated the protocol as helpful. CONCLUSION: The E.M.S. IMMO Protocol Pediatric provides decision-making support whether pediatric spine immobilization is indicated with respect to the cardiopulmonary status of the patient. In a first analysis, the E.M.S. IMMO Protocol Pediatric improves decision making by emergency medical care providers.


Asunto(s)
Servicios Médicos de Urgencia , Traumatismos Vertebrales , Vértebras Cervicales , Niño , Protocolos Clínicos , Servicio de Urgencia en Hospital , Humanos , Inmovilización , Traumatismos Vertebrales/terapia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA