Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Europace ; 16(3): 335-40, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24337158

RESUMEN

AIMS: Catheter-tissue contact is critical for effective lesion creation in radiofrequency catheter ablation (RFCA). In a multicentre prospective study, we assessed the effect of direct contact force (CF) measurement on acute procedural parameters during RFCA of atrial fibrillation (AF). METHODS AND RESULTS: A new open-irrigated tip catheter with CF sensing (SmartTouch™, Biosense Webster Inc.) was used. All the patients underwent the first ablation procedure for paroxysmal AF with antral pulmonary vein (PV) isolation, aiming at entry and exit conduction block in all PVs. Ninety-five patients were enroled in nine centres and successfully underwent ablation. Overall procedure time, fluoroscopy time, and ablation time were 138.0 ± 67.0, 14.3 ± 11.2, and 33.8 ± 19.4 min, respectively. The mean CF value during ablation was 12.2 ± 3.9 g. Force time integral (FTI) analysis showed that patients achieving a value below the median of 543.0gs required longer procedural (158.0 ± 74.0 vs. 117.0 ± 52.0 min, P = 0.004) and fluoroscopy (17.5 ± 13.0 vs. 11.0 ± 7.7 min, P = 0.007) times as compared with those in whom FTI was above this value. Patients in whom the mean CF during ablation was >20 g required shorter procedural time (92.0 ± 23.0 vs. 160.0 ± 67.0 min, P = 0.01) as compared with patients in whom this value was <10 g. Four groin haematomas were the only complications observed. CONCLUSION: Contact force during RFCA for PV isolation affects procedural parameters, in particular procedural and fluoroscopy times, without increasing complications.


Asunto(s)
Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Ablación por Catéter/instrumentación , Fluoroscopía , Sistema de Conducción Cardíaco/cirugía , Tempo Operativo , Venas Pulmonares/cirugía , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Ablación por Catéter/métodos , Diseño de Equipo , Análisis de Falla de Equipo , Femenino , Humanos , Italia , Masculino , Persona de Mediana Edad , Proyectos Piloto , Estrés Mecánico , Tacto , Transductores , Resultado del Tratamiento , Adulto Joven
2.
J Cardiovasc Electrophysiol ; 24(3): 269-73, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23210452

RESUMEN

INTRODUCTION: Aim of this study was to compare efficacy and safety of the new ThermoCool Surround Flow® catheter (SFc) versus the ThermoCool® (TCc) in achieving persistent circumferential electrical isolation of the pulmonary veins (PVs) in patients with paroxysmal atrial fibrillation (AF). METHODS AND RESULTS: This multicenter, randomized, controlled study enrolled patients suffering from paroxysmal AF. Randomization was run in a one-to-one fashion between radiofrequency ablation by TCc or SFc. Aim of PVs ablation was documentation of electrical isolation with exit/entrance block recorded on a circular catheter. Among the 106 enrolled patients, 52 (49.0%) were randomized to TCc and 54 (51.0%) to SFc. Total volume of infused saline solution during the procedure was lower in the SFc than in TCc group (752.7 ± 268.6 mL vs 1,165.9 ± 436.2 mL, P < 0.0001). Number of identified and isolated PVs was similar in the 2 groups. Number of PVs remaining isolated 30 minutes after ablation was higher in the SFc than in TCc group (95.2% vs 90.5%, P < 0.03), mainly driven by acute ablation result in the left PVs (96.1% vs 89.7%, P < 0.04). Complications were seldom and observed only in the TCc group (0% vs 3.84%, P < 0.03). At 6-month follow-up SFc patients reported a trend toward less AF recurrences compared to those in the TCc group (22.9% vs 27.0%, P = 0.69). CONCLUSION: PV isolation by SFc lowered the rate of left PV early reconnections and reduced the volume of infused saline solution while maintaining the safety profile of AF ablation.


Asunto(s)
Fibrilación Atrial/cirugía , Catéteres Cardíacos , Ablación por Catéter/instrumentación , Venas Pulmonares/cirugía , Irrigación Terapéutica/instrumentación , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Ablación por Catéter/efectos adversos , Distribución de Chi-Cuadrado , Técnicas Electrofisiológicas Cardíacas , Diseño de Equipo , Femenino , Humanos , Italia , Masculino , Persona de Mediana Edad , Proyectos Piloto , Valor Predictivo de las Pruebas , Venas Pulmonares/fisiopatología , Recurrencia , Cloruro de Sodio/administración & dosificación , Irrigación Terapéutica/efectos adversos , Factores de Tiempo , Resultado del Tratamiento
3.
J Cardiovasc Med (Hagerstown) ; 22(9): 669-679, 2021 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-32925390

RESUMEN

The number of patients affected by electrical storm has been continuously increasing in emergency departments. Patients are often affected by multiple comorbidities requiring multidisciplinary interventions to achieve a clinical stability. Careful reprogramming of cardiac devices, correction of electrolyte imbalance, knowledge of underlying heart disease and antiarrhythmic drugs in the acute phase play a crucial role. The aim of this review is to provide a comprehensive overview of pharmacological treatment, latest transcatheter ablation techniques and advanced management of patients with electrical storm.


Asunto(s)
Antiarrítmicos/farmacología , Taquicardia Ventricular/terapia , Ablación por Catéter/métodos , Humanos , Manejo de Atención al Paciente/métodos , Manejo de Atención al Paciente/tendencias
4.
J Cardiovasc Med (Hagerstown) ; 22(10): 727-737, 2021 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-33136806

RESUMEN

Ventricular tachycardia is a major health issue in patients with structural heart disease (SHD). Implantable cardioverter defibrillator (ICD) therapy has significantly reduced the risk of sudden cardiac death (SCD) in such patients, but on the other hand, it has led to frequent ICD shocks as an emerging problem, being associated with poor quality of life, frequent hospitalizations and increased mortality. Myocardial scar plays a central role in the genesis and maintenance of re-entrant arrhythmias, as the coexistence of surviving myocardial fibres within fibrotic tissue leads to the formation of slow conduction pathways and to a dispersion of activation and refractoriness that constitutes the milieu for ventricular tachycardia circuits. Catheter ablation has repeatedly proven to be well tolerated and highly effective in treating VT and in the last two decades has benefited from continuous efforts to determine ventricular tachycardia mechanisms by integration with a wide range of invasive and noninvasive imaging techniques such as intracardiac echocardiography, cardiac magnetic resonance, multidetector computed tomography and nuclear imaging. Cardiovascular imaging has become a fundamental aid in planning and guiding catheter ablation procedures by integrating structural and electrophysiological information, enabling the ventricular tachycardia arrhythmogenic substrate to be characterized and effective ablation targets to be identified with increasing precision, and allowing the development of new ablation strategies with improved outcomes. In this review, we provide an overview of the role of cardiac imaging in patients undergoing catheter ablation of ventricular tachycardia.


Asunto(s)
Técnicas de Imagen Cardíaca/métodos , Ablación por Catéter/métodos , Taquicardia Ventricular , Ablación por Catéter/tendencias , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirugía
5.
J Cardiovasc Med (Hagerstown) ; 20(9): 597-605, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31318839

RESUMEN

METHODS: We performed a nationwide survey on the current practice of ventricular tachycardia catheter ablation in Italy during the year 2016. RESULTS: Among 145 operators participating in the survey, 58 (40.0%) did not perform any ventricular tachycardia ablation in 2016. Among those performing ventricular tachycardia ablation, 9 operators (6.2%) performed only right ventricular endocardial catheter ablation, 52 (35.9%) performed endocardial catheter ablation both in the right and left ventricle (LV) and 26 (17.9%) performed both endocardial and epicardial LV catheter ablations. Seventy operators (89.7%) among the 78 performing LV and epicardial ablations treated patients with ischemic cardiomyopathy; ablations in the setting of other causes were less frequently performed. The following were considered as minimum requirements for ventricular tachycardia ablation: presence of a three-dimensional mapping system (120 operators, 82.8%), ICU in the hospital (118 operators, 81.4%), operator's training in high volume centers (93 operators, 64.1%). Twenty-eight operators (19.3%) performed catheter ablation in patients with electrical storm only after hemodynamic stabilization, 41 operators (28.3%) also during the acute phase and 9 operators (6.2%) never performed catheter ablation in electrical storm patients; the remaining 67 operators did not perform ventricular tachycardia ablation at all, or performed ablations only in the right ventricle. CONCLUSION: The present survey provides a snapshot of the current invasive treatment of ventricular tachycardia by catheter ablation. The procedure, especially in the setting of ischemic cardiomyopathy, is performed nationwide. Complex cases, including those with electrical storm, should be managed within a preestablished integrated network of regional referral centers able to transfer patients as soon as possible.


Asunto(s)
Ablación por Catéter/tendencias , Prestación Integrada de Atención de Salud/tendencias , Pautas de la Práctica en Medicina/tendencias , Taquicardia Ventricular/cirugía , Ablación por Catéter/efectos adversos , Encuestas de Atención de la Salud , Disparidades en Atención de Salud/tendencias , Humanos , Italia/epidemiología , Transferencia de Pacientes/tendencias , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/terapia , Regionalización/tendencias , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/epidemiología , Taquicardia Ventricular/fisiopatología , Resultado del Tratamiento
6.
J Interv Card Electrophysiol ; 42(1): 21-6, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25378035

RESUMEN

PURPOSE: Catheter-tissue contact is critical for effective lesion creation in radiofrequency catheter ablation (RFCA). In a multicenter prospective study, we assessed the relationship between catheter contact force (CF) during RFCA for paroxysmal atrial fibrillation (AF) and clinical recurrences over a mid-term follow-up. METHODS: All patients underwent RFCA for paroxysmal AF by antral pulmonary vein (PV) isolation, aiming at entry and exit conduction block in all PVs. A new open-irrigated tip catheter with CF sensing (SmartTouch(TM), Biosense Webster Inc. CA) was used. All patients were followed for at least 12 months and the relationship between CF and clinical outcomes assessed. RESULTS: One year follow-up was available in 92/95 of the patients enrolled. Acute PV isolation was achieved in 100 % of the veins. Mean CF during RFCA was 12.2 ± 3.9 g. Mean force-time integral (FTI) was 733 ± 505 gs. Following the 3-month blanking period, 17 (18 %) patients experienced at least 1 atrial tachyarrhythmia relapse. There was no statistical difference in mean CF (13 ± 3.4 g vs 12 ± 4 g, p = 0.32) and mean FTI (713 ± 487 gs vs 822 ± 590 gs, p = 0.42) between patients with and without arrhythmia recurrences. Recurrences were recorded in 22 % of patients achieving a mean FTI value below the median of 544 gs and in 15 % of patients with a mean FTI value above the median (p = 0.64). CONCLUSIONS: RFCA with CF data during PV isolation for paroxysmal AF improves physician's knowledge on catheter-tissue contact. In the present dataset, however, higher CF values did not impact mid-term clinical RFCA outcome.


Asunto(s)
Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/instrumentación , Ablación por Catéter/métodos , Sistema de Conducción Cardíaco/cirugía , Venas Pulmonares/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Fibrilación Atrial/prevención & control , Diseño de Equipo , Análisis de Falla de Equipo , Estudios de Seguimiento , Humanos , Italia , Estudios Longitudinales , Persona de Mediana Edad , Recurrencia , Estrés Mecánico , Resultado del Tratamiento
7.
J Midwifery Womens Health ; 49(4): 355-8, 2004.
Artículo en Inglés | MEDLINE | ID: mdl-15236717

RESUMEN

To evaluate the efficacy of a polyethylene glycol electrolyte solution (PEG-4000) in pregnant women affected by constipation, 40 consecutive pregnant women from 6 to 38 weeks' gestation were enrolled in this preliminary study. Constipation was defined as spontaneous evacuation less than four times a week or the presence of symptoms such as defecation pain, rectal urgency, tenesmus, anal injury, or abdominal pain. A PEG-4000 solution (Isocolan, also marketed in the United States as Golitely/Nulitely) was administered for 15 days at a dose of 250 mL by mouth once or twice a day. The number of bowel movements per week, the presence or absence of liquid stools, tenesmus, urgency, defecation pain, anal lesions, and abdominal pain were evaluated before and after 15 days of treatment. Treatment with PEG-4000 significantly increased the evacuation episodes per week (from 1.66 +/- 0.48 to 3.16 +/- 1.05; P <.01), and constipation was resolved in 27 of 37 women (73%). Defecation pain, anal injury, and abdominal pain significantly improved after PEG-4000 administration. Improvement occurred in both patients with new-onset constipation during pregnancy as well as patients with a history of constipation before pregnancy. These preliminary findings indicate that PEG-4000 may be an effective choice for the treatment of constipation during pregnancy.


Asunto(s)
Estreñimiento/tratamiento farmacológico , Electrólitos/administración & dosificación , Fármacos Gastrointestinales/administración & dosificación , Polietilenglicoles/administración & dosificación , Complicaciones del Embarazo/tratamiento farmacológico , Adulto , Defecación/efectos de los fármacos , Esquema de Medicación , Femenino , Tránsito Gastrointestinal/efectos de los fármacos , Humanos , Embarazo , Factores de Tiempo , Resultado del Tratamiento
8.
Trials ; 12: 44, 2011 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-21324118

RESUMEN

BACKGROUND: Heart failure(HF) and atrial fibrillation(AF) frequently coexist in the same patient and are associated with increased mortality and frequent hospitalizations. As the concomitance of AF and HF is often associated with a poor prognosis, the prompt treatment of AF in HF patients may significantly improve outcome. METHODS/DESIGN: Recent implantable cardiac resynchronization (CRT) devices allow electrical therapies to treat AF automatically. TRADE-HF (trial registration: NCT00345592; http://www.clinicaltrials.gov) is a prospective, randomized, double arm study aimed at demonstrating the efficacy of an automatic, device-based therapy for treatment of atrial tachycardia and fibrillation(AT/AF) in patients indicated for CRT. The study compares automatic electrical therapy to a traditional more usual treatment of AT/AF: the goal is to demonstrate a reduction in a combined endpoint of unplanned hospitalizations for cardiac reasons, death from cardiovascular causes or permanent AF when using automatic atrial therapy as compared to the traditional approach involving hospitalization for symptoms and in-hospital treatment of AT/AF. DISCUSSION: CRT pacemaker with the additional ability to convert AF as well as ventricular arrhythmias may play a simultaneous role in rhythm control and HF treatment. The value of the systematic implantation of CRT ICDs with the capacity to deliver atrial therapy in HF patients at risk of AF has not yet been explored. The TRADE-HF study will assess in CRT patients whether a strategy based on automatic management of atrial arrhythmias might be a valuable option to reduce the number of hospital admission and to reduce the progression the arrhythmia to a permanent form. TRIAL REGISTRATION: NCT00345592.


Asunto(s)
Fibrilación Atrial/terapia , Dispositivos de Terapia de Resincronización Cardíaca , Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca/terapia , Proyectos de Investigación , Fibrilación Atrial/complicaciones , Fibrilación Atrial/mortalidad , Fibrilación Atrial/fisiopatología , Terapia de Resincronización Cardíaca/efectos adversos , Terapia de Resincronización Cardíaca/mortalidad , Diseño de Equipo , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/fisiopatología , Hospitalización , Humanos , Italia , Estudios Prospectivos , Resultado del Tratamiento
9.
G Ital Cardiol (Rome) ; 11(2): 138-41, 2010 Feb.
Artículo en Italiano | MEDLINE | ID: mdl-20408477

RESUMEN

BACKGROUND: The aim of the present study was to investigate the relationship between carotid and aortic atherosclerosis in asymptomatic subjects. METHODS: Eighty-three consecutive patients without history of cardio- and cerebrovascular disease, referred for transesophageal echocardiography, were enrolled into the study. RESULTS: Aortic plaques were found in 40 out of 83 patients, whereas carotid atherosclerosis was present in 43% of the entire study population and in 75% of patients with aortic atherosclerosis (30 out of 40 patients). At multivariate logistic analysis, the presence of carotid atherosclerosis was a predictor of aortic atheroma, independently of traditional risk factors. CONCLUSIONS: In asymptomatic patients, aortic plaque occurrence may reflect the presence of carotid plaques and an ultrasound assessment should be advised.


Asunto(s)
Enfermedades de la Aorta/diagnóstico por imagen , Aterosclerosis/diagnóstico por imagen , Enfermedades de las Arterias Carótidas/diagnóstico por imagen , Adulto , Anciano , Enfermedades de la Aorta/patología , Aterosclerosis/patología , Enfermedades de las Arterias Carótidas/patología , Diagnóstico Precoz , Ecocardiografía Transesofágica , Femenino , Humanos , Modelos Logísticos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Valor Predictivo de las Pruebas , Factores de Riesgo , Índice de Severidad de la Enfermedad , Túnica Media/diagnóstico por imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA